[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-965184":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},965184,701,1,"单选题","对于泡沫-水喷淋系统联动控制功能测试的描述不正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","打开泡沫液试验阀，压力开关应动作",true,{"key":16,"text":17,"correct":18},"B","压力水经延迟器进入报警管路，水力警铃应报警，压力开关应动作，并启动消防水泵",false,{"key":20,"text":21,"correct":18},"C","同时报警管路一部分水进入压力释放阀",{"key":23,"text":24,"correct":18},"D","压力释放阀动作后，泡沫液控制阀自动开启，向系统供给泡沫液，系统试验阀随即有泡沫混合液流出","泡沫-水喷淋系统联动控制功能：测试时，打开泡沫液试验阀，报警阀组应及时开启，之后压力水经延迟器进入报警管路，水力警铃应报警，压力开关应动作，并启动消防水泵；同时报警管路一部分水进入压力释放阀，压力释放阀动作后，泡沫液控制阀自动开启，向系统供绐泡沫液，系统试验阀随即有泡沫混合掖流出。",{"id":6,"name":27,"category":28,"favorite":29},"高级技能","建筑工程",0]