[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-964754":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},964754,701,1,"单选题","对于细水雾开式或预作用式灭火系统的应急机械启动工作方式描述不正确的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","手动关闭联动设备并切断电源",false,{"key":16,"text":17,"correct":14},"B","启动细水雾消防水泵，手动打开对应区域分区控制阀",{"key":19,"text":20,"correct":14},"C","细水雾控制阀开启后，若为开式灭火系统，细水雾灭火系统管网开始充水，实施灭火",{"key":22,"text":23,"correct":24},"D","若为湿式灭火系统，细水雾灭火系统管网开始充水，待闭式细水雾洒水喷头玻璃球爆破后即可实施灭火",true,"当报警控制器或灭火控制器失效时，或在急需紧急启动开式或预作用细水雾灭火系统时，值守人员在确定所有人员撒离现场后，按以下步骤实施应急机械启动：手动关闭联动设备并切断电源；启动细水雾消防水泵，手动打开对应区域分区控制阀；细水雾控制阀开启后，若为开式灭火系统，细水雾灭火系统管网幵始充水，实施灭火；若为预作用式灭火系统，细水雾灭火系统管网开始充水，待闭式细水雾洒水喷头玻璃球爆破后即可实施灭火。",{"id":6,"name":27,"category":28,"favorite":29},"高级技能","建筑工程",0]