[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-50":3},{"library":4,"page":9,"limit":9,"total":10,"questions":11,"related":540},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,50,2862,[12,33,45,63,73,85,97,109,121,133,139,145,151,157,169,177,188,200,215,230,236,246,258,270,280,295,301,307,317,329,342,348,362,368,380,388,398,410,422,434,446,460,466,472,478,486,498,510,518,526],{"id":13,"libraryId":5,"type":14,"typeLabel":15,"stem":16,"options":17,"answer":19,"analysis":32},963794,1,"单选题","下列（ ）属于地面水平最低照度不应低于10.0lx的场所。",[18,22,26,29],{"key":19,"text":20,"correct":21},"A","老年人照料设施",true,{"key":23,"text":24,"correct":25},"B","配电房、消防控制室、消防水泵房",false,{"key":27,"text":28,"correct":25},"C","内步行街两侧的商铺",{"key":30,"text":31,"correct":25},"D","人员较少厂房内的生产场所","",{"id":34,"libraryId":5,"type":14,"typeLabel":15,"stem":35,"options":36,"answer":30,"analysis":32},963795,"消防应急照明和疏散指示系统的线路保护方式不正确的是（ ）。",[37,39,41,43],{"key":19,"text":38,"correct":25},"系统线路暗敷时，应采用金属管、可弯曲金属电气导管或B1级以上的刚性塑料管保护",{"key":23,"text":40,"correct":25},"系统线路明敷时，应采用金属管、可弯曲金属电气导管或槽盒保护",{"key":27,"text":42,"correct":25},"矿物绝缘类不燃性电缆可直接明敷",{"key":30,"text":44,"correct":21},"矿物绝緣类不燃性电缆应采用槽盒保护",{"id":46,"libraryId":5,"type":47,"typeLabel":48,"stem":49,"options":50,"answer":62,"analysis":32},963796,2,"多选题","制定《消防应急照明和疏散指示系统技术标准》（GB51309）的意义是（ ）。",[51,53,55,57,59],{"key":19,"text":52,"correct":21},"合理设计消防应急照明和疏散指示系统",{"key":23,"text":54,"correct":21},"保证消防应急照明和疏散指示系统的施工质量",{"key":27,"text":56,"correct":21},"保证系统正常运行",{"key":30,"text":58,"correct":25},"保护人身和财产安全",{"key":60,"text":61,"correct":25},"E","保证施工质量","ABC",{"id":64,"libraryId":5,"type":65,"typeLabel":66,"stem":67,"options":68,"answer":70,"analysis":32},963797,3,"判断题","消防水泵房严寒、寒冷等冬季结冰地区采暖温度不应低于10℃，但当无人值守时不应低于5℃。",[69,71],{"key":19,"text":70,"correct":21},"正确",{"key":23,"text":72,"correct":25},"错误",{"id":74,"libraryId":5,"type":14,"typeLabel":15,"stem":75,"options":76,"answer":30,"analysis":32},963798,"《消防给水及消火栓系统技术规范》（GB50974）自（ ）起实施。",[77,79,81,83],{"key":19,"text":78,"correct":25},"2014年1月29日",{"key":23,"text":80,"correct":25},"2014年5月1日",{"key":27,"text":82,"correct":25},"2014年8月1日",{"key":30,"text":84,"correct":21},"2014年10月1日",{"id":86,"libraryId":5,"type":14,"typeLabel":15,"stem":87,"options":88,"answer":27,"analysis":32},963799,"消防水池的总蓄水有效容积大于（ ）m3时，宜设两格能独立使用的消防水池",[89,91,93,95],{"key":19,"text":90,"correct":25},"100",{"key":23,"text":92,"correct":25},"200",{"key":27,"text":94,"correct":21},"500",{"key":30,"text":96,"correct":25},"1000",{"id":98,"libraryId":5,"type":14,"typeLabel":15,"stem":99,"options":100,"answer":30,"analysis":32},963800,"当采用柴油机消防水泵时，下列不符合要求的是（ ）。",[101,103,105,107],{"key":19,"text":102,"correct":25},"柴油机消防水泵应采用压缩式点火型柴油机",{"key":23,"text":104,"correct":25},"柴油机消防水泵的蓄电池应保证消防水泵随时自动启泵的要求",{"key":27,"text":106,"correct":25},"柴油机额定功率应校核海拔调试和环境温度度对柴油机功率的影响",{"key":30,"text":108,"correct":21},"柴油机消防水泵应具备连续工作的性能，试验运行时间不应小于12h",{"id":110,"libraryId":5,"type":14,"typeLabel":15,"stem":111,"options":112,"answer":23,"analysis":32},963801,"稳压泵的设计压力应保持系统最不利点处水灭火设施在准工作状态时的静水压力应大于（ ）MPa",[113,115,117,119],{"key":19,"text":114,"correct":25},"0.07",{"key":23,"text":116,"correct":21},"0.15",{"key":27,"text":118,"correct":25},"0.1",{"key":30,"text":120,"correct":25},"0.05",{"id":122,"libraryId":5,"type":14,"typeLabel":15,"stem":123,"options":124,"answer":27,"analysis":32},963802,"消防水泵房设置不符合要求的是（ ）。",[125,127,129,131],{"key":19,"text":126,"correct":25},"独立建造的消防水泵房耐火等级不应低于二级",{"key":23,"text":128,"correct":25},"附设在建筑物内的消防水泵房，不应设置在地下三层以下，或室内地面与室外出入口地平高差大于10m的地下楼层",{"key":27,"text":130,"correct":21},"附设在建筑物内的消防水泵房，应采用耐火极限不低于1.50h的隔墙和楼板与其它部位隔开",{"key":30,"text":132,"correct":25},"水泵房疏散门应直通安全出口，且开向疏散走道的门应采用甲级防火门",{"id":134,"libraryId":5,"type":65,"typeLabel":66,"stem":135,"options":136,"answer":70,"analysis":32},963803,"消防水泵的吸水管穿越消防水池时，应采用柔性套管：采用刚性防水套管时应在水泵吸水泵上设置柔性接头，且管径不应大于DN150。",[137,138],{"key":19,"text":70,"correct":21},{"key":23,"text":72,"correct":25},{"id":140,"libraryId":5,"type":65,"typeLabel":66,"stem":141,"options":142,"answer":72,"analysis":32},963804,"干式消火栓系统的充水时间不应大于3min",[143,144],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":146,"libraryId":5,"type":65,"typeLabel":66,"stem":147,"options":148,"answer":72,"analysis":32},963805,"《消防给水及消火栓系统技术规范》（GB50974）适用于新建、扩建、改建的工业与民用建筑工程的消防给水及消火栓系统的施工，验收和维护管理。",[149,150],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":152,"libraryId":5,"type":65,"typeLabel":66,"stem":153,"options":154,"answer":72,"analysis":32},963806,"《自动喷水灭火系统施工及验收规范》（GB50261）适用于工业与民用建筑中设置的自动喷水灭火系统的设计、施工、验收及维护管理。",[155,156],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":158,"libraryId":5,"type":14,"typeLabel":15,"stem":159,"options":160,"answer":27,"analysis":32},963807,"《自动喷水灭火系统设计规范》（GB50084）自（ ）实施",[161,163,165,167],{"key":19,"text":162,"correct":25},"2017年5月27日",{"key":23,"text":164,"correct":25},"2017年10月1日",{"key":27,"text":166,"correct":21},"2018年1月1日",{"key":30,"text":168,"correct":25},"2018年3月1日",{"id":170,"libraryId":5,"type":14,"typeLabel":15,"stem":171,"options":172,"answer":27,"analysis":32},963808,"《自动喷水灭火系统设计规范》（GB50261）自（ ）实施",[173,174,175,176],{"key":19,"text":162,"correct":25},{"key":23,"text":164,"correct":25},{"key":27,"text":166,"correct":21},{"key":30,"text":168,"correct":25},{"id":178,"libraryId":5,"type":14,"typeLabel":15,"stem":179,"options":180,"answer":19,"analysis":32},963809,"一个湿式报警阀组控制的喷头数量不宜超过（ ）只。",[181,183,185,187],{"key":19,"text":182,"correct":21},"800",{"key":23,"text":184,"correct":25},"700",{"key":27,"text":186,"correct":25},"600",{"key":30,"text":94,"correct":25},{"id":189,"libraryId":5,"type":14,"typeLabel":15,"stem":190,"options":191,"answer":27,"analysis":32},963810,"报警阀组安装的位置应符合设计要求；当设计无要求时，报警阀组应安装在便于操作的明显位置，距室内地面高度宜为1.2m；两侧与墙的距离不应小于0.5m，正面与墙的距离不应小于（ ）m。",[192,194,196,198],{"key":19,"text":193,"correct":25},"0.5",{"key":23,"text":195,"correct":25},"1",{"key":27,"text":197,"correct":21},"1.2",{"key":30,"text":199,"correct":25},"1.5",{"id":201,"libraryId":5,"type":47,"typeLabel":48,"stem":202,"options":203,"answer":214,"analysis":32},963811,"《自动喷水灭火系统设计规范》（GB50084）不适用于（ ）自动喷水灭火系统的设计。",[204,206,208,210,212],{"key":19,"text":205,"correct":21},"飞机库",{"key":23,"text":207,"correct":21},"核电站",{"key":27,"text":209,"correct":25},"民用建筑",{"key":30,"text":211,"correct":21},"火工品式",{"key":60,"text":213,"correct":25},"工业建筑","ABD",{"id":216,"libraryId":5,"type":47,"typeLabel":48,"stem":217,"options":218,"answer":229,"analysis":32},963812,"自动喷水灭火系统管网安装完毕后，应对管网进行（ ）。",[219,221,223,225,227],{"key":19,"text":220,"correct":25},"系统调试",{"key":23,"text":222,"correct":21},"强度试验",{"key":27,"text":224,"correct":21},"严密性试验",{"key":30,"text":226,"correct":21},"冲洗",{"key":60,"text":228,"correct":25},"吹扫","BCD",{"id":231,"libraryId":5,"type":65,"typeLabel":66,"stem":232,"options":233,"answer":72,"analysis":32},963813,"《自动喷水灭火系统施工及验收规范》（6850261）于2017年5月27日起施行。",[234,235],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":237,"libraryId":5,"type":14,"typeLabel":15,"stem":238,"options":239,"answer":30,"analysis":32},963814,"《泡沬灭火系统设计规范》（GB50151）自（ ）实施",[240,241,242,244],{"key":19,"text":162,"correct":25},{"key":23,"text":166,"correct":25},{"key":27,"text":243,"correct":25},"2010年8月18日",{"key":30,"text":245,"correct":21},"2011年6月1日",{"id":247,"libraryId":5,"type":14,"typeLabel":15,"stem":248,"options":249,"answer":30,"analysis":32},963815,"泡沫液泵应能耐受不低于（ ）min的空载运转。",[250,252,254,256],{"key":19,"text":251,"correct":25},"3",{"key":23,"text":253,"correct":25},"5",{"key":27,"text":255,"correct":25},"8",{"key":30,"text":257,"correct":21},"10",{"id":259,"libraryId":5,"type":14,"typeLabel":15,"stem":260,"options":261,"answer":23,"analysis":32},963816,"固定式泡沬灭火系统的设计应满足在泡沬消防水泵或泡沬混合液泵启动后，将泡沬混合液或泡沬输送到保护对像的时间不大于（ ）。",[262,264,266,268],{"key":19,"text":263,"correct":25},"3min",{"key":23,"text":265,"correct":21},"5min",{"key":27,"text":267,"correct":25},"10min",{"key":30,"text":269,"correct":25},"15min",{"id":271,"libraryId":5,"type":14,"typeLabel":15,"stem":272,"options":273,"answer":23,"analysis":32},963817,"《泡沬灭火系统施工及验收规范》》（GB50281）自（ ）实施",[274,276,278,279],{"key":19,"text":275,"correct":25},"2006年6月19日",{"key":23,"text":277,"correct":21},"2006年11月1日",{"key":27,"text":243,"correct":25},{"key":30,"text":245,"correct":25},{"id":281,"libraryId":5,"type":47,"typeLabel":48,"stem":282,"options":283,"answer":294,"analysis":32},963818,"《泡沫灭火系统设计规范》（GB50151）不适用于（ ）等场所设置的泡沫灭火系统的设计。",[284,286,288,290,292],{"key":19,"text":285,"correct":25},"民用建筑工程",{"key":23,"text":287,"correct":25},"石油化工储罐区",{"key":27,"text":289,"correct":21},"船舶",{"key":30,"text":291,"correct":21},"海上石油平台",{"key":60,"text":293,"correct":25},"石油化工企业","CD",{"id":296,"libraryId":5,"type":65,"typeLabel":66,"stem":297,"options":298,"answer":72,"analysis":32},963819,"为合理的设计泡沬灭火系统，规范验收和维护管理，减少火灾损失，保护人身和财产安全，特制定《泡沬灭火系统设计规范》（GB50151）",[299,300],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":302,"libraryId":5,"type":65,"typeLabel":66,"stem":303,"options":304,"answer":72,"analysis":32},963820,"《泡沬灭火系统施工及验收规范》（GB50281）自2016年11月1曰起实施。",[305,306],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":308,"libraryId":5,"type":14,"typeLabel":15,"stem":309,"options":310,"answer":30,"analysis":32},963821,"《自动跟踪定位自射流灭火系统》（GB25204）自（ ）起实施",[311,312,313,315],{"key":19,"text":245,"correct":25},{"key":23,"text":243,"correct":25},{"key":27,"text":314,"correct":25},"2010年9月26日",{"key":30,"text":316,"correct":21},"2011年3月1日",{"id":318,"libraryId":5,"type":14,"typeLabel":15,"stem":319,"options":320,"answer":27,"analysis":32},963822,"《自动跟踪定位自射流灭火系统》（GB25204）适用于以水或泡沬混合液为喷射介质的，利用（ ）进行早期自动定位，并运用自动控制技术来实现灭火的各种自动跟踪定位射流灭火系统。",[321,323,325,327],{"key":19,"text":322,"correct":25},"卫星",{"key":23,"text":324,"correct":25},"红外线",{"key":27,"text":326,"correct":21},"数字图像",{"key":30,"text":328,"correct":25},"其他火灾探测组件",{"id":330,"libraryId":5,"type":47,"typeLabel":48,"stem":331,"options":332,"answer":341,"analysis":32},963823,"《自动跟踪定位自射流灭火系统》（GB25204）的制定的意义是（ ）。",[333,335,337,339],{"key":19,"text":334,"correct":21},"合理设计自动跟踪定位射流灭火系统",{"key":23,"text":336,"correct":21},"保障系统相关产品的质量和使用功能",{"key":27,"text":338,"correct":21},"规范维护管理",{"key":30,"text":340,"correct":21},"减少火灾危害，保护人身和财产安全","ABCD",{"id":343,"libraryId":5,"type":65,"typeLabel":66,"stem":344,"options":345,"answer":70,"analysis":32},963824,"自动跟踪定位射流灭火系统是利用红外线、数字图像或其他火灾探测组件对火、温度等的探测进行早期火灾的自动跟踪定位，并运用自动控制方式来实现灭火的各种室内外固定射流灭火系统。",[346,347],{"key":19,"text":70,"correct":21},{"key":23,"text":72,"correct":25},{"id":349,"libraryId":5,"type":47,"typeLabel":48,"stem":350,"options":351,"answer":62,"analysis":32},963825,"《气体灭火系统设计规范》（GB50370）适用于新建、扩建、改建的工业和民用建筑中设置的（ ）灭火系统的设计。",[352,354,356,358,360],{"key":19,"text":353,"correct":21},"七氟丙烷",{"key":23,"text":355,"correct":21},"IG541混合气体",{"key":27,"text":357,"correct":21},"热气溶胶全淹没灭火系统",{"key":30,"text":359,"correct":25},"混合灭火系统",{"key":60,"text":361,"correct":25},"二氧化碳气体",{"id":363,"libraryId":5,"type":65,"typeLabel":66,"stem":364,"options":365,"answer":70,"analysis":32},963826,"为合理设计气体灭火系统，減少火灾危害，保护人身和财产的安全，特制定《气体灭火系统设计规范》（GB50370）。",[366,367],{"key":19,"text":70,"correct":21},{"key":23,"text":72,"correct":25},{"id":369,"libraryId":5,"type":14,"typeLabel":15,"stem":370,"options":371,"answer":23,"analysis":32},963827,"《气体灭火系统设计规范》（GB50370）自（ ）起实施。",[372,374,376,378],{"key":19,"text":373,"correct":25},"2006年3月2日",{"key":23,"text":375,"correct":21},"2006年5月1日",{"key":27,"text":377,"correct":25},"2007年1月24日",{"key":30,"text":379,"correct":25},"2007年7月1日",{"id":381,"libraryId":5,"type":14,"typeLabel":15,"stem":382,"options":383,"answer":30,"analysis":32},963828,"《气体灭火系统施工及验收规范》（GB50263）自（ ）日起实施。",[384,385,386,387],{"key":19,"text":373,"correct":25},{"key":23,"text":375,"correct":25},{"key":27,"text":377,"correct":25},{"key":30,"text":379,"correct":21},{"id":389,"libraryId":5,"type":14,"typeLabel":15,"stem":390,"options":391,"answer":19,"analysis":32},963829,"气体灭火系统两个或两个以上的防护区采用组含分配系统时，一个组合分配系统所保护的防护区不应超过（ ）个。",[392,393,395,397],{"key":19,"text":255,"correct":21},{"key":23,"text":394,"correct":25},"7",{"key":27,"text":396,"correct":25},"6",{"key":30,"text":253,"correct":25},{"id":399,"libraryId":5,"type":14,"typeLabel":15,"stem":400,"options":401,"answer":30,"analysis":32},963830,"气体灭火系统的储存装置（ ）小时内不能重新充装恢复工作的，应按系统原储存量的100%设置备用量。",[402,404,406,408],{"key":19,"text":403,"correct":25},"24",{"key":23,"text":405,"correct":25},"36",{"key":27,"text":407,"correct":25},"48",{"key":30,"text":409,"correct":21},"72",{"id":411,"libraryId":5,"type":14,"typeLabel":15,"stem":412,"options":413,"answer":23,"analysis":32},963831,"气体灭火系统的设计温度应采用（ ）。",[414,416,418,420],{"key":19,"text":415,"correct":25},"15℃",{"key":23,"text":417,"correct":21},"20℃",{"key":27,"text":419,"correct":25},"25℃",{"key":30,"text":421,"correct":25},"30℃",{"id":423,"libraryId":5,"type":14,"typeLabel":15,"stem":424,"options":425,"answer":19,"analysis":32},963832,"气体灭火系统喷头的保护高度和保护半径，不符合规定的是（ ）。",[426,428,430,432],{"key":19,"text":427,"correct":21},"最大保护高度不宜大于4.5m",{"key":23,"text":429,"correct":25},"最小保护高度不宜小于0.3m",{"key":27,"text":431,"correct":25},"喷头的安装高度小于1.5m时，保护半径不宜大于4.5m",{"key":30,"text":433,"correct":25},"喷头的安装高度不小于1.5m时，保护半径不应大于7.5m",{"id":435,"libraryId":5,"type":14,"typeLabel":15,"stem":436,"options":437,"answer":27,"analysis":32},963833,"七氟丙烷灭火系统的泄压口应位于防护区净高的（ ）以上。",[438,440,442,444],{"key":19,"text":439,"correct":25},"1\u002F2",{"key":23,"text":441,"correct":25},"1\u002F3",{"key":27,"text":443,"correct":21},"2\u002F3",{"key":30,"text":445,"correct":25},"3\u002F4",{"id":447,"libraryId":5,"type":47,"typeLabel":48,"stem":448,"options":449,"answer":229,"analysis":32},963834,"《气体灭火系统施工及验收规范》（GB50263）适用于建新、扩建、改建工程中设置的气体灭火系统工程的（ ）。",[450,452,454,456,458],{"key":19,"text":451,"correct":25},"设计",{"key":23,"text":453,"correct":21},"施工",{"key":27,"text":455,"correct":21},"验收",{"key":30,"text":457,"correct":21},"维护管理",{"key":60,"text":459,"correct":25},"调试",{"id":461,"libraryId":5,"type":65,"typeLabel":66,"stem":462,"options":463,"answer":72,"analysis":32},963835,"气体灭火系统喷头的布置应满足喷放后气体灭火剂在防护区内均匀分布的要求。当保护对象属可燃液体时，喷头射流方向应朝向液体表面。",[464,465],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":467,"libraryId":5,"type":65,"typeLabel":66,"stem":468,"options":469,"answer":72,"analysis":32},963836,"为合理设计气体灭火系统，统一气体灭火系统工程施工及验收要求，保障气体灭火系统工程质量，特制定《气体灭火系统施工及验收规范》（GB50263）。",[470,471],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":473,"libraryId":5,"type":65,"typeLabel":66,"stem":474,"options":475,"answer":72,"analysis":32},963837,"为保障建筑消防设施的施工质量和使用功能，确保建筑消防设施完好有效，特制定《建筑消防设施的维护管理》（GB25201）。",[476,477],{"key":19,"text":70,"correct":25},{"key":23,"text":72,"correct":21},{"id":479,"libraryId":5,"type":14,"typeLabel":15,"stem":480,"options":481,"answer":27,"analysis":32},963838,"《建筑消防设施的维护管理》（GB25201）自（ ）起实施。",[482,483,484,485],{"key":19,"text":314,"correct":25},{"key":23,"text":379,"correct":25},{"key":27,"text":316,"correct":21},{"key":30,"text":377,"correct":25},{"id":487,"libraryId":5,"type":14,"typeLabel":15,"stem":488,"options":489,"answer":19,"analysis":32},963839,"建筑消防设施至少每（ ）检査一次，检査对象包括全部系统设备、组件等。",[490,492,494,496],{"key":19,"text":491,"correct":21},"年",{"key":23,"text":493,"correct":25},"2年",{"key":27,"text":495,"correct":25},"半年",{"key":30,"text":497,"correct":25},"3个月",{"id":499,"libraryId":5,"type":14,"typeLabel":15,"stem":500,"options":501,"answer":30,"analysis":32},963840,"建筑消防设施的原始技术资料应保存（ ）。",[502,504,506,508],{"key":19,"text":503,"correct":25},"一年",{"key":23,"text":505,"correct":25},"三年",{"key":27,"text":507,"correct":25},"五年",{"key":30,"text":509,"correct":21},"长期",{"id":511,"libraryId":5,"type":14,"typeLabel":15,"stem":512,"options":513,"answer":19,"analysis":32},963841,"《消防控制室值班记录表》和《建筑消防设施巡査记录表》的存档时间不应少于（ ）。",[514,515,516,517],{"key":19,"text":503,"correct":21},{"key":23,"text":505,"correct":25},{"key":27,"text":507,"correct":25},{"key":30,"text":509,"correct":25},{"id":519,"libraryId":5,"type":47,"typeLabel":48,"stem":520,"options":521,"answer":341,"analysis":32},963842,"建筑消防设施的维护管理包括（ ）。 A.值班 B.巡查 C.检测 D.维修",[522,523,524,525],{"key":19,"text":19,"correct":21},{"key":23,"text":23,"correct":21},{"key":27,"text":27,"correct":21},{"key":30,"text":30,"correct":21},{"id":527,"libraryId":5,"type":47,"typeLabel":48,"stem":528,"options":529,"answer":341,"analysis":32},963843,"下列关于消防控制室值班人员接到报警信号后的做法，正确的是（ ）。",[530,532,534,536,538],{"key":19,"text":531,"correct":21},"接到火灾报警信息后，应以最快方式确认",{"key":23,"text":533,"correct":21},"确认属于误报时，查找误报原因并填写《建筑消防设施故障维修记录表》",{"key":27,"text":535,"correct":21},"火灾确认后，立即将火灾报警联动控制开关转入自动状态（处于自动状态的除外），同时拨打“119”火警电话报警",{"key":30,"text":537,"correct":21},"立即启动单位内部灭火和应急疏散预案，",{"key":60,"text":539,"correct":25},"同时报告单位消防安全管理人，单位消防安全管理人接到报告后应立即赶赴现场",[541,544,547,550,553,556],{"id":14,"name":542,"category":7,"favorite":543},"领导干部任职前廉政法规知识测试题",92,{"id":545,"name":546,"category":7,"favorite":14},595,"建筑结构与设备",{"id":548,"name":549,"category":7,"favorite":14},715,"招标采购专业知识与法律法规",{"id":551,"name":552,"category":7,"favorite":14},848,"市政方向-通用基础",{"id":554,"name":555,"category":7,"favorite":8},534,"BIM工程师",{"id":557,"name":555,"category":7,"favorite":8},535]