[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-40":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":487},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,40,50,2862,[13,28,34,40,46,52,58,64,70,76,82,88,104,112,120,132,140,148,160,172,182,190,198,206,218,226,238,246,254,264,272,283,291,299,311,323,335,347,359,374,386,399,408,420,433,445,458,469,475,481],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},963285,3,"判断题","仅需要报警，不需要联动自动消防设备的保护对象宜采用区域报警系统。（）",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},963286,"集中报警系统主要由火灾探测器、手动火灾报警按钮、火灾声光警报器、消防应急广播、消防专用电话、消防控制室图形显示装置、集中型火灾报警控制器、消防联动控制系统等组成。（）",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},963287,"消防联动控制器是按设定的控制逻辑向各相关受控设备发出联动控制信号，并接收相关设备的联动反馈信号的设备。（）",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},963288,"不仅需要报警，同时需要联动自动消防设备，且只设置一台具有集中控制功能的火灾报警控制器和消防联动控制器的保护对象，应采用集中报警系统，并设置一个消防控制室。（）",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},963289,"由消防控制室的消防控制设备、集中火灾报警控制器、区域火灾报警控制器和火灾探测器等组成，或由消防控制室的消防控制设备、火灾报警控制器、区域显示器和火灾探测器等组成，功能复杂的火灾自动报警系统称为控制中心报警系统。（）",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},963290,"设置两个及两个以上消防控制室的保护对象，或已设置两个及两个以上集中报警系统的保护对象，应采用控制中心报警系统。（）",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},963291,"干式系统适用于环境温度不低于4℃且不高于70℃。（）",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},963292,"水幕系统是自动喷水灭火系统中唯一的一种不以灭火为主要目的的系统。（）",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},963293,"IG-541是一种氮气、氩气、CO2气体组成的混合气体（其中含52%的N2、40%的Ar、8%的CO2）。（）",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},963294,"由于惰性气体纯粹来自自然界，是一种无毒、无色、无味、惰性及不导电的纯“绿色”压缩气体，故惰性气体灭火系统又称为洁净气体灭火系统。（）",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":21,"analysis":27},963295,"管网灭火系统是指按一定的应用条件进行设计计算，将灭火剂从储存装置经由干管、支管输送至喷放组件实施喷放的灭火系统。（）",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":90,"typeLabel":91,"stem":92,"options":93,"answer":20,"analysis":27},963296,1,"单选题","（）的作用是通过探测保护现场的火焰、热量和烟雾等相关参数发出报警信号，显示火灾发生的部位，发出声、光报警信号以通知相关人员进行疏散和实施火灾扑救。",[94,96,98,101],{"key":20,"text":95,"correct":22},"火灾探测报警系统",{"key":24,"text":97,"correct":26},"火灾自动报警系统",{"key":99,"text":100,"correct":26},"C","消防联动控制系统",{"key":102,"text":103,"correct":26},"D","消防设施操作系统",{"id":105,"libraryId":5,"type":90,"typeLabel":91,"stem":106,"options":107,"answer":24,"analysis":27},963297,"（）是一种能够在早期发现和通报火情，并能够向各类消防联动设施发出控制信号，实现预设消防功能而设置在建（构）筑物中的自动消防设施。",[108,109,110,111],{"key":20,"text":95,"correct":26},{"key":24,"text":97,"correct":22},{"key":99,"text":100,"correct":26},{"key":102,"text":103,"correct":26},{"id":113,"libraryId":5,"type":90,"typeLabel":91,"stem":114,"options":115,"answer":24,"analysis":27},963298,"（）是指探测火灾早期特征，发出火灾报警信号，为人员疏散、防止火灾蔓延和启动自动灭火设备提供控制与指示的消防系统。",[116,117,118,119],{"key":20,"text":95,"correct":26},{"key":24,"text":97,"correct":22},{"key":99,"text":100,"correct":26},{"key":102,"text":103,"correct":26},{"id":121,"libraryId":5,"type":90,"typeLabel":91,"stem":122,"options":123,"answer":20,"analysis":27},963299,"（）由区域火灾报警控制器和火灾探测器组成，功能简单的火灾自动报警系统称为区域报警系统。",[124,126,128,130],{"key":20,"text":125,"correct":22},"区域报警系统",{"key":24,"text":127,"correct":26},"集中报警系统",{"key":99,"text":129,"correct":26},"控制中心报警系统",{"key":102,"text":131,"correct":26},"集中区域兼容报警系统",{"id":133,"libraryId":5,"type":90,"typeLabel":91,"stem":134,"options":135,"answer":20,"analysis":27},963300,"仅需要报警，不需要联动自动消防设备的保护对象宜采用（）。",[136,137,138,139],{"key":20,"text":125,"correct":22},{"key":24,"text":127,"correct":26},{"key":99,"text":129,"correct":26},{"key":102,"text":131,"correct":26},{"id":141,"libraryId":5,"type":90,"typeLabel":91,"stem":142,"options":143,"answer":24,"analysis":27},963301,"由集中火灾报警控制器、区域火灾报警控制器、区域显示器和火灾探测器等组成，功能较复杂的火灾自动报警系统称为（）。",[144,145,146,147],{"key":20,"text":125,"correct":26},{"key":24,"text":127,"correct":22},{"key":99,"text":129,"correct":26},{"key":102,"text":131,"correct":26},{"id":149,"libraryId":5,"type":90,"typeLabel":91,"stem":150,"options":151,"answer":102,"analysis":27},963302,"（）能发出区别于环境声、光的火灾报警信号，警示人们迅速进行安全疏散和采取火灾扑救措施。",[152,154,156,158],{"key":20,"text":153,"correct":26},"触发器件",{"key":24,"text":155,"correct":26},"火灾报警控制器",{"key":99,"text":157,"correct":26},"手动报警按钮",{"key":102,"text":159,"correct":22},"火灾警报装置",{"id":161,"libraryId":5,"type":90,"typeLabel":91,"stem":162,"options":163,"answer":20,"analysis":27},963304,"以下那个系统为闭式系统（）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"湿式系统",{"key":24,"text":167,"correct":26},"水喷雾系统",{"key":99,"text":169,"correct":26},"雨淋系统",{"key":102,"text":171,"correct":26},"水幕系统",{"id":173,"libraryId":5,"type":90,"typeLabel":91,"stem":174,"options":175,"answer":24,"analysis":27},963305,"（）准工作状态时配水管道内充满用于启动系统的有压气体，火灾发生时喷头受热开放，配水管道排气充水后喷水灭火，系统响应速度比湿式系统慢。",[176,177,179,181],{"key":20,"text":165,"correct":26},{"key":24,"text":178,"correct":22},"干式系统",{"key":99,"text":180,"correct":26},"预作用系统",{"key":102,"text":171,"correct":26},{"id":183,"libraryId":5,"type":90,"typeLabel":91,"stem":184,"options":185,"answer":102,"analysis":27},963306,"（）是自动喷水灭火系统中唯一的一种不以灭火为主要目的的系统。",[186,187,188,189],{"key":20,"text":165,"correct":26},{"key":24,"text":178,"correct":26},{"key":99,"text":180,"correct":26},{"key":102,"text":171,"correct":22},{"id":191,"libraryId":5,"type":90,"typeLabel":91,"stem":192,"options":193,"answer":99,"analysis":27},963307,"（）主要由闭式喷头、预作用报警阀组或雨淋阀组、充气设备、管道、供水设施和火灾探测报警控制装置等组成。",[194,195,196,197],{"key":20,"text":165,"correct":26},{"key":24,"text":178,"correct":26},{"key":99,"text":180,"correct":22},{"key":102,"text":171,"correct":26},{"id":199,"libraryId":5,"type":90,"typeLabel":91,"stem":200,"options":201,"answer":99,"analysis":27},963308,"（）处于准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持水源侧管道内充水的压力，系统侧管道内平时无水或充以有压气体。",[202,203,204,205],{"key":20,"text":165,"correct":26},{"key":24,"text":178,"correct":26},{"key":99,"text":180,"correct":22},{"key":102,"text":171,"correct":26},{"id":207,"libraryId":5,"type":90,"typeLabel":91,"stem":208,"options":209,"answer":24,"analysis":27},963310,"（）具有灭火能力强、全球温室效应潜能值小、臭氧层损耗能力为零、不会破坏大气环境、灭火后无残留物等特点。",[210,212,214,216],{"key":20,"text":211,"correct":26},"二氧化碳灭火系统",{"key":24,"text":213,"correct":22},"七氟丙烷灭火系统",{"key":99,"text":215,"correct":26},"惰性气体灭火系统",{"key":102,"text":217,"correct":26},"热气溶胶灭火系统",{"id":219,"libraryId":5,"type":90,"typeLabel":91,"stem":220,"options":221,"answer":102,"analysis":27},963311,"（）是以由固体化学混合物（热气溶胶发生剂）经燃烧反应生成具有灭火性质的气溶胶作为灭火介质的灭火系统。",[222,223,224,225],{"key":20,"text":211,"correct":26},{"key":24,"text":213,"correct":26},{"key":99,"text":215,"correct":26},{"key":102,"text":217,"correct":22},{"id":227,"libraryId":5,"type":90,"typeLabel":91,"stem":228,"options":229,"answer":20,"analysis":27},963312,"（）需设单独储瓶间，气体喷放需通过放在保护区内的管网系统进行，适用于计算机房、档案馆、贵重物品仓库、电信中心等较大空间的保护区。",[230,232,234,236],{"key":20,"text":231,"correct":22},"管网灭火系统",{"key":24,"text":233,"correct":26},"预制灭火系统",{"key":99,"text":235,"correct":26},"全淹没气体灭火系统",{"key":102,"text":237,"correct":26},"局部应用气体灭火系统",{"id":239,"libraryId":5,"type":90,"typeLabel":91,"stem":240,"options":241,"answer":24,"analysis":27},963313,"（）是指按一定的应用条件，将灭火剂储存装置和喷放组件等预先设计、组装成套且具有联动控制功能的灭火系统。",[242,243,244,245],{"key":20,"text":231,"correct":26},{"key":24,"text":233,"correct":22},{"key":99,"text":235,"correct":26},{"key":102,"text":237,"correct":26},{"id":247,"libraryId":5,"type":90,"typeLabel":91,"stem":248,"options":249,"answer":99,"analysis":27},963314,"（）适用于扑救液体火灾，灭火前能切断气源的气体火灾，电气火灾，固体表面火灾。",[250,251,252,253],{"key":20,"text":231,"correct":26},{"key":24,"text":233,"correct":26},{"key":99,"text":235,"correct":22},{"key":102,"text":237,"correct":26},{"id":255,"libraryId":5,"type":90,"typeLabel":91,"stem":256,"options":257,"answer":24,"analysis":27},963315,"（）是指用一套灭火剂储存装置保护一个防护区或保护对象的灭火系统。",[258,259,261,263],{"key":20,"text":231,"correct":26},{"key":24,"text":260,"correct":22},"单元独立灭火系统",{"key":99,"text":262,"correct":26},"组合分配灭火系统",{"key":102,"text":237,"correct":26},{"id":265,"libraryId":5,"type":90,"typeLabel":91,"stem":266,"options":267,"answer":24,"analysis":27},963316,"（）不设选择阀，对于需设置气体灭火系统的每个防护区或保护对象分别单独设置灭火剂储存装置。",[268,269,270,271],{"key":20,"text":231,"correct":26},{"key":24,"text":260,"correct":22},{"key":99,"text":262,"correct":26},{"key":102,"text":237,"correct":26},{"id":273,"libraryId":5,"type":90,"typeLabel":91,"stem":274,"options":275,"answer":24,"analysis":27},963317,"（）是指灭火剂在瓶组内用驱动气体进行加压储存，系统动作时灭火剂靠瓶组内的充压气体进行输送的灭火系统。",[276,278,280,282],{"key":20,"text":277,"correct":26},"自压式气体灭火系统",{"key":24,"text":279,"correct":22},"内储压式气体灭火系统",{"key":99,"text":281,"correct":26},"外储压式气体灭火系统",{"key":102,"text":237,"correct":26},{"id":284,"libraryId":5,"type":90,"typeLabel":91,"stem":285,"options":286,"answer":99,"analysis":27},963318,"（）是指系统动作时气体灭火剂由专设的充压气体瓶组按设计压力对其进行充压的灭火系统。",[287,288,289,290],{"key":20,"text":277,"correct":26},{"key":24,"text":279,"correct":26},{"key":99,"text":281,"correct":22},{"key":102,"text":237,"correct":26},{"id":292,"libraryId":5,"type":90,"typeLabel":91,"stem":293,"options":294,"answer":24,"analysis":27},963319,"（）一般由灭火剂瓶组、驱动气体瓶组（可选）、容器阀、减压装置、驱动装置、集流管（只限多瓶组）、连接管、喷嘴、信号反馈装置、安全泄放装置、控制盘、检漏装置、管路管件、柜体等部件组成。",[295,296,297,298],{"key":20,"text":231,"correct":26},{"key":24,"text":233,"correct":22},{"key":99,"text":235,"correct":26},{"key":102,"text":237,"correct":26},{"id":300,"libraryId":5,"type":90,"typeLabel":91,"stem":301,"options":302,"answer":20,"analysis":27},963320,"防护区围护结构承受内压的允许压强不宜低于（）。",[303,305,307,309],{"key":20,"text":304,"correct":22},"1．2kpa",{"key":24,"text":306,"correct":26},"1．5kpa",{"key":99,"text":308,"correct":26},"1．0h",{"key":102,"text":310,"correct":26},"1．01kpa",{"id":312,"libraryId":5,"type":90,"typeLabel":91,"stem":313,"options":314,"answer":99,"analysis":27},963321,"防护区应设置泄压口，七氟丙烷、二氧化碳灭火系统的泄压口应位于防护区净高的（）以上。",[315,317,319,321],{"key":20,"text":316,"correct":26},"1\u002F2",{"key":24,"text":318,"correct":26},"1\u002F3",{"key":99,"text":320,"correct":22},"2\u002F3",{"key":102,"text":322,"correct":26},"3\u002F5",{"id":324,"libraryId":5,"type":90,"typeLabel":91,"stem":325,"options":326,"answer":24,"analysis":27},963322,"采用局部应用灭火系统的保护对象，应符合下列规定：保护对象周围的空气流动速度不宜大于（），必要时应采取挡风措施。",[327,329,331,333],{"key":20,"text":328,"correct":26},"1m\u002Fs",{"key":24,"text":330,"correct":22},"3m\u002Fs",{"key":99,"text":332,"correct":26},"5m\u002Fs",{"key":102,"text":334,"correct":26},"10m\u002Fs",{"id":336,"libraryId":5,"type":90,"typeLabel":91,"stem":337,"options":338,"answer":99,"analysis":27},963323,"高倍数泡沫灭火系统发泡倍数为（）。",[339,341,343,345],{"key":20,"text":340,"correct":26},"小于20",{"key":24,"text":342,"correct":26},"21-200",{"key":99,"text":344,"correct":22},"201-1000",{"key":102,"text":346,"correct":26},"1000以上",{"id":348,"libraryId":5,"type":90,"typeLabel":91,"stem":349,"options":350,"answer":20,"analysis":27},963324,"（）是主要的消防水源。",[351,353,355,357],{"key":20,"text":352,"correct":22},"市政给水",{"key":24,"text":354,"correct":26},"消防水池",{"key":99,"text":356,"correct":26},"天然水源",{"key":102,"text":358,"correct":26},"消防水箱",{"id":360,"libraryId":5,"type":361,"typeLabel":362,"stem":363,"options":364,"answer":373,"analysis":27},963325,2,"多选题","以下哪些地方需要设置火灾自动报警系统（）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"任一层建筑面积大于1500㎡或总建筑面积大于3000㎡的商店．展览．财贸金融．客运和货运等类似用途的建筑，总建筑面积大于500㎡的地下或半地下商店。",{"key":24,"text":368,"correct":22},"图书或文物的珍藏库，每座藏书超过50万册的图书馆，重要的档案馆。",{"key":99,"text":370,"correct":22},"地市级及以上广播电视建筑．邮政建筑．电信建筑，城市或区域性电力．交通和防灾等指挥调度建筑。",{"key":102,"text":372,"correct":22},"歌舞娱乐放映游艺场所。","ABCD",{"id":375,"libraryId":5,"type":361,"typeLabel":362,"stem":376,"options":377,"answer":373,"analysis":27},963326,"消防联动控制系统主要由（）装置等设备组成，完成对建筑内相关消防设备的控制功能并接收和显示设备的反馈信号。",[378,380,382,384],{"key":20,"text":379,"correct":22},"消防联动控制器",{"key":24,"text":381,"correct":22},"输入\u002F输出模块",{"key":99,"text":383,"correct":22},"消防电气控制装置",{"key":102,"text":385,"correct":22},"消防电动",{"id":387,"libraryId":5,"type":361,"typeLabel":362,"stem":388,"options":389,"answer":398,"analysis":27},963327,"自动喷水灭火系统是由（）等组件以及管道、供水设施等组成，能在发生火灾时喷水的自动灭火系统。",[390,392,394,396],{"key":20,"text":391,"correct":22},"洒水喷头",{"key":24,"text":393,"correct":22},"报警阀组",{"key":99,"text":395,"correct":22},"水流报警装置（水流指示器或压力开关）",{"key":102,"text":397,"correct":26},"警报装置","ABC",{"id":400,"libraryId":5,"type":361,"typeLabel":362,"stem":401,"options":402,"answer":407,"analysis":27},963328,"以下那个系统为开式系统（）。",[403,404,405,406],{"key":20,"text":165,"correct":26},{"key":24,"text":178,"correct":26},{"key":99,"text":169,"correct":22},{"key":102,"text":171,"correct":22},"CD",{"id":409,"libraryId":5,"type":361,"typeLabel":362,"stem":410,"options":411,"answer":373,"analysis":27},963329,"管网气体灭火系统处于自动控制时，在接收到同一防护区域内与首次报警的火灾探测器或手动火灾报警按钮相邻的感温火灾探测器、火焰探测器或手动火灾报警按钮的第二个联动触发信号后，灭火控制器发出联动指令，关闭\u002F停止联动设备（）。",[412,414,416,418],{"key":20,"text":413,"correct":22},"防护区域的送\u002F排风机及送\u002F排风阀门",{"key":24,"text":415,"correct":22},"通风和空气调节系统",{"key":99,"text":417,"correct":22},"防火阀门",{"key":102,"text":419,"correct":22},"防护区域的门．窗",{"id":421,"libraryId":5,"type":361,"typeLabel":362,"stem":422,"options":423,"answer":432,"analysis":27},963330,"泡沫灭火系统按照喷射方式可以分为（）。",[424,426,428,430],{"key":20,"text":425,"correct":22},"液上泡沫灭火系统",{"key":24,"text":427,"correct":22},"液下泡沫灭火系统",{"key":99,"text":429,"correct":26},"半液上泡沫灭火系统",{"key":102,"text":431,"correct":22},"半液下泡沫灭火系统","ABD",{"id":434,"libraryId":5,"type":361,"typeLabel":362,"stem":435,"options":436,"answer":373,"analysis":27},963331,"二氧化碳灭火系统适用于扑救（）。",[437,439,441,443],{"key":20,"text":438,"correct":22},"灭火前可切断气源的气体火灾",{"key":24,"text":440,"correct":22},"液体火灾或石蜡、沥青等可熔化的固体火灾",{"key":99,"text":442,"correct":22},"固体表面火灾及棉毛、织物、纸张等部分固体深位火灾",{"key":102,"text":444,"correct":22},"电气火灾",{"id":446,"libraryId":5,"type":361,"typeLabel":362,"stem":447,"options":448,"answer":457,"analysis":27},963332,"二氧化碳灭火系统在灭火时使用的是二氧化碳的（）作用。",[449,451,453,455],{"key":20,"text":450,"correct":22},"冷却",{"key":24,"text":452,"correct":22},"窒息",{"key":99,"text":454,"correct":26},"隔离",{"key":102,"text":456,"correct":26},"化学抑制","AB",{"id":459,"libraryId":5,"type":361,"typeLabel":362,"stem":460,"options":461,"answer":398,"analysis":27},963333,"泡沫灭火系统主要通过（）实现灭火，具有安全可靠、经济实用、灭火效率高、无毒性的特点。",[462,464,466,468],{"key":20,"text":463,"correct":22},"隔氧窒息作用",{"key":24,"text":465,"correct":22},"辐射热阻隔作用",{"key":99,"text":467,"correct":22},"吸热冷却作用",{"key":102,"text":456,"correct":26},{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":21,"analysis":27},963334,"火灾探测器可对烟雾、温度、火焰辐射、气体浓度等火灾参数进行响应，并自动产生火灾报警信号。（）",[473,474],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":21,"analysis":27},963335,"根据仓库储存物品及其包装材料的火灾危险性，将仓库火灾危险等级划分为I、Ⅱ、Ⅲ级。（）",[479,480],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":21,"analysis":27},963336,"根据火灾荷载、室内空间条件、人员密集程度、采用自动喷水灭火系统扑救初期火灾的难易程度，以及疏散及外部增援条件等因素，将自动喷水灭火系统的设置场所危险等级划分为以下四类八级。（）",[485,486],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[488,491,494,497,500,503],{"id":90,"name":489,"category":7,"favorite":490},"领导干部任职前廉政法规知识测试题",92,{"id":492,"name":493,"category":7,"favorite":90},595,"建筑结构与设备",{"id":495,"name":496,"category":7,"favorite":90},715,"招标采购专业知识与法律法规",{"id":498,"name":499,"category":7,"favorite":90},848,"市政方向-通用基础",{"id":501,"name":502,"category":7,"favorite":8},534,"BIM工程师",{"id":504,"name":502,"category":7,"favorite":8},535]