[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-37":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":549},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,37,50,2862,[13,34,46,58,70,82,94,106,118,136,151,166,181,195,210,224,238,249,263,274,288,303,317,331,341,347,353,359,365,371,377,383,389,395,401,407,413,419,425,431,437,443,455,467,479,491,503,515,527,537],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},963134,1,"单选题","下列场所应设置疏散照明的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","建筑面积为200m2的营业厅",false,{"key":24,"text":25,"correct":22},"B","建筑面积为100m2的地下公共活动场所",{"key":27,"text":28,"correct":29},"C","公共建筑内的疏散走道",true,{"key":31,"text":32,"correct":22},"D","建筑高度为24m的住宅建筑","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},963135,"下列不属于集中电源非集中控制型消防应急照明和疏散指示系统组成部分的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":29},"应急照明控制器",{"key":24,"text":41,"correct":22},"应急照明分配电装置",{"key":27,"text":43,"correct":22},"应急照明集中电源",{"key":31,"text":45,"correct":22},"集中电源型消防应急灯具",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},963136,"下列关于灭火器的类型选择不适用于A类火灾场所的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"水基型水雾灭火器",{"key":24,"text":53,"correct":22},"磷酸铵盐干粉灭火器",{"key":27,"text":55,"correct":29},"碳酸氢钠干粉灭火器",{"key":31,"text":57,"correct":22},"水基型泡沫灭火器",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},963137,"灭火器有效喷射灭火的距离，是从灭火器喷嘴项端起，到喷出的灭火剂最集中处中心的水平距离是指（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"效喷射时间",{"key":24,"text":65,"correct":22},"喷射滞后时间",{"key":27,"text":67,"correct":29},"有效喷射距离",{"key":31,"text":69,"correct":22},"喷射剩余率",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},963138,"喷射剩余率是指额定充装状态下的灭火器，在喷射到内部压力与外部环境压力相等时（也就是不再有灭火剂从灭火器喷嘴喷出时），内部剩余灭火剂量相对于额定充装量的百分比。一般要求是在（20±5）℃时不大于10%，在灭火器的使用温度范围内不大于（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"10%",{"key":24,"text":77,"correct":29},"15%",{"key":27,"text":79,"correct":22},"20%",{"key":31,"text":81,"correct":22},"25%",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},963139,"下列关于防火门的耐火极限，说法不正确的是（ ）。甲级防火门的耐火极限为不低于（ ）小时。",[86,88,90,92],{"key":20,"text":87,"correct":22},"甲级防火门的耐火极限为不低于1.5h",{"key":24,"text":89,"correct":22},"乙级防火门的耐火极限为不低于1.0h",{"key":27,"text":91,"correct":22},"丙级防火门的耐火极限为不低于0.5h",{"key":31,"text":93,"correct":29},"丁级防火门的耐火极限为不低于0.3h",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},963140,"下列关于逃生避难器材的设置说法不正确的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"逃生滑道配备在建筑高度为60m的楼层内",{"key":24,"text":101,"correct":22},"逃生缓降器配备在建筑高度为30m的楼层内",{"key":27,"text":103,"correct":29},"悬挂式逃生梯配备在建筑高度为20m的楼层内",{"key":31,"text":105,"correct":22},"逃生绳应配备在建筑高度为6m的楼层内",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},963141,"在建筑高度为40m的楼层内应配备防护时间不少于（ ）min的自救呼吸器。",[110,112,114,116],{"key":20,"text":111,"correct":22},"15",{"key":24,"text":113,"correct":29},"20",{"key":27,"text":115,"correct":22},"25",{"key":31,"text":117,"correct":22},"30",{"id":119,"libraryId":5,"type":120,"typeLabel":121,"stem":122,"options":123,"answer":135,"analysis":33},963142,2,"多选题","下列属于消防水泵主要性能参数的有（ ）。",[124,126,128,130,132],{"key":20,"text":125,"correct":29},"流量",{"key":24,"text":127,"correct":29},"扬程",{"key":27,"text":129,"correct":29},"轴功率",{"key":31,"text":131,"correct":29},"效率",{"key":133,"text":134,"correct":29},"E","转速","ABCDE",{"id":137,"libraryId":5,"type":120,"typeLabel":121,"stem":138,"options":139,"answer":150,"analysis":33},963143,"下列属于消防水泵接合器组成的有（ ）。",[140,142,144,146,148],{"key":20,"text":141,"correct":29},"本体",{"key":24,"text":143,"correct":29},"消防接口",{"key":27,"text":145,"correct":29},"安全阀",{"key":31,"text":147,"correct":29},"水流止回和水流截断装置",{"key":133,"text":149,"correct":22},"排气阀","ABCD",{"id":152,"libraryId":5,"type":120,"typeLabel":121,"stem":153,"options":154,"answer":165,"analysis":33},963144,"下列场所应设置消防水泵接合器的有（ ）。",[155,157,159,161,163],{"key":20,"text":156,"correct":29},"设有自动喷水灭火系统的高层民用建筑",{"key":24,"text":158,"correct":29},"水喷雾灭火系统",{"key":27,"text":160,"correct":22},"室内消火栓给系统",{"key":31,"text":162,"correct":29},"泡沫灭火系统",{"key":133,"text":164,"correct":29},"固定消防炮灭火系统","ABDE",{"id":167,"libraryId":5,"type":120,"typeLabel":121,"stem":168,"options":169,"answer":180,"analysis":33},963145,"根据消防水泵接合器按连接方式可分为（ ）。",[170,172,174,176,178],{"key":20,"text":171,"correct":29},"法兰式",{"key":24,"text":173,"correct":22},"焊接式",{"key":27,"text":175,"correct":29},"螺纹式",{"key":31,"text":177,"correct":22},"卡箍式",{"key":133,"text":179,"correct":22},"承插式","AC",{"id":182,"libraryId":5,"type":120,"typeLabel":121,"stem":183,"options":184,"answer":194,"analysis":33},963146,"下列建筑或场所应设置室内消火栓系统（ ）",[185,187,188,190,192],{"key":20,"text":186,"correct":29},"建筑占地面积为800m2的仓库",{"key":24,"text":32,"correct":29},{"key":27,"text":189,"correct":29},"体积大于5000m3的车站",{"key":31,"text":191,"correct":22},"超过1000个座位的礼堂",{"key":133,"text":193,"correct":29},"建筑体积为20000m3的办公建筑","ABCE",{"id":196,"libraryId":5,"type":120,"typeLabel":121,"stem":197,"options":198,"answer":209,"analysis":33},963147,"下列场所或部位应设置防烟设施有（ ）。",[199,201,203,205,207],{"key":20,"text":200,"correct":29},"防烟楼梯间及其前室",{"key":24,"text":202,"correct":29},"消防电梯间前室或合用前室",{"key":27,"text":204,"correct":29},"避难走道的前室、避难层（间）",{"key":31,"text":206,"correct":22},"前室或合用前室采用敞开的阳台、凹廊",{"key":133,"text":208,"correct":22},"建筑内长度大于20m的疏散走道","ABC",{"id":211,"libraryId":5,"type":120,"typeLabel":121,"stem":212,"options":213,"answer":194,"analysis":33},963148,"厂房或仓库的下列场所或部位应设置排烟设施有（ ）。",[214,216,218,220,222],{"key":20,"text":215,"correct":29},"人员或可燃物较多的丙类生产场所，丙类厂房内建筑面积大于300m2且经常有人停留或可燃物较多的地上房间",{"key":24,"text":217,"correct":29},"建筑面积大于5000m2的丁类生产车间",{"key":27,"text":219,"correct":29},"占地面积大于1000m2的丙类仓库",{"key":31,"text":221,"correct":22},"高度大于30m的高层厂房（仓库）内长度大于20m的疏散走道",{"key":133,"text":223,"correct":29},"其他厂房（仓库）内长度大于40m的疏散走道",{"id":225,"libraryId":5,"type":120,"typeLabel":121,"stem":226,"options":227,"answer":237,"analysis":33},963149,"民用建筑的下列场所或部位应设置排烟设施的是（ ）",[228,230,232,234,236],{"key":20,"text":229,"correct":22},"设置在一、二、三层且房间建筑面积大于200m2的歌舞娱乐放映游艺场所",{"key":24,"text":231,"correct":29},"中庭",{"key":27,"text":233,"correct":29},"公共建筑内建筑面积大于100m2且经常有人停留的地上房间",{"key":31,"text":235,"correct":22},"公共建筑内建筑面积大于200m2且可燃物较多的地上房间",{"key":133,"text":208,"correct":29},"BCE",{"id":239,"libraryId":5,"type":120,"typeLabel":121,"stem":240,"options":241,"answer":209,"analysis":33},963150,"下列属于自带电源集中控制型应急照明和疏散指示系统组成部件的有（ ）。",[242,244,245,247,248],{"key":20,"text":243,"correct":29},"自带电源型消防应急灯具",{"key":24,"text":39,"correct":29},{"key":27,"text":246,"correct":29},"应急照明配电箱",{"key":31,"text":43,"correct":22},{"key":133,"text":41,"correct":22},{"id":250,"libraryId":5,"type":120,"typeLabel":121,"stem":251,"options":252,"answer":194,"analysis":33},963151,"根据灭火器按所充装灭火剂的不同可分为（ ）。",[253,255,257,259,261],{"key":20,"text":254,"correct":29},"水基型灭火器",{"key":24,"text":256,"correct":29},"干粉型灭火器",{"key":27,"text":258,"correct":29},"二氧化碳型灭火器",{"key":31,"text":260,"correct":22},"贮气瓶式灭火器",{"key":133,"text":262,"correct":29},"洁净气体型灭火器",{"id":264,"libraryId":5,"type":120,"typeLabel":121,"stem":265,"options":266,"answer":273,"analysis":33},963152,"干粉型灭火器内充装的灭火剂，根据充装的干粉灭火剂的不同可分为（ ）。",[267,268,269,270,271],{"key":20,"text":55,"correct":29},{"key":24,"text":53,"correct":29},{"key":27,"text":57,"correct":22},{"key":31,"text":51,"correct":22},{"key":133,"text":272,"correct":29},"灭金属火专用干粉灭火器","ABE",{"id":275,"libraryId":5,"type":120,"typeLabel":121,"stem":276,"options":277,"answer":135,"analysis":33},963153,"在选择灭火器时，下列属于应考虑的因素有（ ）。",[278,280,282,284,286],{"key":20,"text":279,"correct":29},"灭火器配置场所的火灾种类",{"key":24,"text":281,"correct":29},"灭火器配置场所的最低基准",{"key":27,"text":283,"correct":29},"灭火器配置的最大保护半径",{"key":31,"text":285,"correct":29},"灭火器的灭火效能和通用性",{"key":133,"text":287,"correct":29},"灭火剂对保护物品的污损程度",{"id":289,"libraryId":5,"type":120,"typeLabel":121,"stem":290,"options":291,"answer":302,"analysis":33},963154,"下列场所应设置消防电梯的有（ ）。",[292,294,296,298,300],{"key":20,"text":293,"correct":22},"建筑高度为33m的住宅建筑",{"key":24,"text":295,"correct":22},"建筑高度为32m的二类高层公共建筑",{"key":27,"text":297,"correct":29},"5层及以上且总建筑面积大于3000m2的老年人照料设施",{"key":31,"text":299,"correct":29},"设置消防电梯的建筑的地下或半地下室",{"key":133,"text":301,"correct":29},"埋深大于10m且总建筑面积大于3000m2的其他地下或半地下建筑","CDE",{"id":304,"libraryId":5,"type":120,"typeLabel":121,"stem":305,"options":306,"answer":237,"analysis":33},963155,"下列关于消防电梯的设置说法正确的有（ ）。",[307,309,311,313,315],{"key":20,"text":308,"correct":22},"电梯轿厢内部采用不燃材料装修，并设置专用救援对讲电话",{"key":24,"text":310,"correct":29},"电梯的动力与控制电缆、导线、控制面板均采取相关防水措施",{"key":27,"text":312,"correct":29},"电梯前室内均设有机械防烟或自然排烟设施",{"key":31,"text":314,"correct":22},"电梯能每层停靠，其载重量不小于600kg",{"key":133,"text":316,"correct":29},"在首层的消防电梯入口处均设置供消防员使用的操作按钮",{"id":318,"libraryId":5,"type":120,"typeLabel":121,"stem":319,"options":320,"answer":135,"analysis":33},963156,"常见的建筑火灾逃生避难器材有（ ）等。",[321,323,325,327,329],{"key":20,"text":322,"correct":29},"逃生缓降器",{"key":24,"text":324,"correct":29},"逃生梯",{"key":27,"text":326,"correct":29},"应急逃生器",{"key":31,"text":328,"correct":29},"逃生绳、",{"key":133,"text":330,"correct":29},"过滤式消防自救呼吸器",{"id":332,"libraryId":5,"type":333,"typeLabel":334,"stem":335,"options":336,"answer":338,"analysis":33},963157,3,"判断题","消防水源是指向水灭火设施、车载或手抬等移动消防水泵、固定消防水泵等提供消防用水的水源，是灭火成功的基本保证。",[337,339],{"key":20,"text":338,"correct":29},"正确",{"key":24,"text":340,"correct":22},"错误",{"id":342,"libraryId":5,"type":333,"typeLabel":334,"stem":343,"options":344,"answer":338,"analysis":33},963158,"消防水泵按用途可分为供水消防泵、稳压消防泵、供泡沫液消防泵。",[345,346],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":348,"libraryId":5,"type":333,"typeLabel":334,"stem":349,"options":350,"answer":340,"analysis":33},963159,"效率是原动机输送给水泵的功率。",[351,352],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":354,"libraryId":5,"type":333,"typeLabel":334,"stem":355,"options":356,"answer":340,"analysis":33},963160,"地上式适用于寒冷地区；地下式（应有明显标志）适用于温暖地区；墙壁式安装在建筑物的墙角处，不占位置，使用方便，但设置不明显。一般应使用地上式水泵接合器。",[357,358],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":360,"libraryId":5,"type":333,"typeLabel":334,"stem":361,"options":362,"answer":338,"analysis":33},963161,"设置高位水箱的目的主要是储存建筑初期火灾所需的消防用水量，保证初期火灾消防给水管网的消防水压。",[363,364],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":366,"libraryId":5,"type":333,"typeLabel":334,"stem":367,"options":368,"answer":338,"analysis":33},963162,"对于采用临时高压消防给水系统的高层或多层建筑，当消防水箱设置高度不能满足系统最不利点处灭火设备所需的水压要求时，应设置稳压设备。",[369,370],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":372,"libraryId":5,"type":333,"typeLabel":334,"stem":373,"options":374,"answer":338,"analysis":33},963163,"低压室外消火栓的作用是为消防车等消防设备提供消防用水，或通过消防车和水泵接合器为室内灭火设施提供消防用水；高压室外消火栓经常保持足够的压力和消防用水量，火灾发生时，现场的火灾扑救人员可直接连接水带与水枪出水灭火。",[375,376],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":378,"libraryId":5,"type":333,"typeLabel":334,"stem":379,"options":380,"answer":338,"analysis":33},963164,"《建筑设计防火规范》（GB50016）规定，高层住宅建筑的公共部位和公共建筑内应设置灭火器，其他住宅建筑的公共部位宜设置灭火器；厂房、仓库、储罐（区）和堆场应设置灭火器。",[381,382],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":384,"libraryId":5,"type":333,"typeLabel":334,"stem":385,"options":386,"answer":340,"analysis":33},963165,"灭火器按结构形式不同，贮气瓶式和贮压式灭火器等。",[387,388],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":390,"libraryId":5,"type":333,"typeLabel":334,"stem":391,"options":392,"answer":338,"analysis":33},963166,"手提式灭火器是指能够在其内部压力作用下将所装的灭火剂喷出以扑救火灾，并可手提移动的灭火器具。",[393,394],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":396,"libraryId":5,"type":333,"typeLabel":334,"stem":397,"options":398,"answer":340,"analysis":33},963167,"推车式灭火器是指装有轮子可由两人推（或拉）至火场，且能在其内部压力作用下将所装的灭火剂喷出，以扑救火灾的灭火器具。",[399,400],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":402,"libraryId":5,"type":333,"typeLabel":334,"stem":403,"options":404,"answer":340,"analysis":33},963168,"贮压式灭火器是指灭火剂由灭火器的贮气瓶释放的压缩气体或液化气体的压力驱动的灭火器。",[405,406],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":408,"libraryId":5,"type":333,"typeLabel":334,"stem":409,"options":410,"answer":340,"analysis":33},963169,"贮压式灭火器是指灭火剂由储存于灭火器同一容器内的压缩气体或灭火剂蒸气贮压式灭火器。该类灭火器的特点是动力气体与灭火剂分开储存，动力气体储存在专用的小钢瓶内，有外置与内置两种形式，使用时将高压气体放出至灭火剂储瓶内，作驱动灭火剂的动力气体。（ ）",[411,412],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":414,"libraryId":5,"type":333,"typeLabel":334,"stem":415,"options":416,"answer":340,"analysis":33},963170,"水基型、泡沫型灭火器就不能在高于4℃的环境中使用，过低的环境温度会导致这些灭火器出现灭火剂冻结而不能喷射。",[417,418],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":420,"libraryId":5,"type":333,"typeLabel":334,"stem":421,"options":422,"answer":340,"analysis":33},963171,"消防电梯是指设置在建筑的耐火封闭结构内，具有前室、备用电源以及其他防火保护、控制和信号等功能，在正常情况下可为普通乘客使用，在建筑发生火灾时能供消防员使用的电梯。",[423,424],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":426,"libraryId":5,"type":333,"typeLabel":334,"stem":427,"options":428,"answer":338,"analysis":33},963172,"建筑火灾逃生避难器材是在发生建筑火灾的情况下，遇险人员逃离火场时所使用的辅助逃生器材，它是对建筑物内应急疏散通道的必要补充。",[429,430],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":432,"libraryId":5,"type":333,"typeLabel":334,"stem":433,"options":434,"answer":340,"analysis":33},963173,"建筑火灾逃生避难器材按器材结构可分为单人逃生类和多人逃生类。",[435,436],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":29},{"id":438,"libraryId":5,"type":333,"typeLabel":334,"stem":439,"options":440,"answer":338,"analysis":33},963174,"逃生缓降器、逃生梯、逃生滑道、应急逃生器、逃生绳应安装在建筑物袋形走道尽头或室内的窗边、阳台凹廊以及公共走道、屋顶平台等处，室外安装应有防雨、防晒措施。",[441,442],{"key":20,"text":338,"correct":29},{"key":24,"text":340,"correct":22},{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":31,"analysis":33},963175,"下列情况可不设置消防水池的是（ ）。",[447,449,451,453],{"key":20,"text":448,"correct":22},"当生产、生活用水量达到最大时，市政给水管网或入户引入管不能满足室内、室外消防给水设计流量",{"key":24,"text":450,"correct":22},"当采用一路消防供水，且室外消火栓设计流量为30L\u002Fs",{"key":27,"text":452,"correct":22},"市政消防给水设计流量小于建筑室内外消防给水设计流量",{"key":31,"text":454,"correct":29},"某建筑高度为50m，采用一路消防供水",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":24,"analysis":33},963176,"天然水源的设计枯水流量保证率应根据城乡规模和工业项目的重要性、火灾危险性和经济合理性等因素综合确定，宜为（ ）。",[459,461,463,465],{"key":20,"text":460,"correct":22},"80%～90%",{"key":24,"text":462,"correct":29},"90%～97%",{"key":27,"text":464,"correct":22},"80%～87%",{"key":31,"text":466,"correct":22},"90%～95%",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":27,"analysis":33},963177,"消防泵的并联是通过两台或两台以上的消防泵同时向消防给水系统供水。消防泵并联的目的主要在于（ ）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"增加扬程",{"key":24,"text":474,"correct":22},"保持扬程",{"key":27,"text":476,"correct":29},"增加流量",{"key":31,"text":478,"correct":22},"保持流量",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":27,"analysis":33},963178,"下列关于消防泵的串联的说法错误的是（ ）。",[483,485,487,489],{"key":20,"text":484,"correct":22},"消防泵的串联是将一台泵的出水口与另一台泵的吸水管直接连接且两台泵同时运行",{"key":24,"text":486,"correct":22},"消防泵的串联在流量不变时可增加扬程",{"key":27,"text":488,"correct":29},"消防泵的串联在流量叠加时可降低扬程",{"key":31,"text":490,"correct":22},"当单台消防泵的扬程不能满足最不利点处的水压要求时，系统可采用串联消防给水系统",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":31,"analysis":33},963179,"（ ）是供消防车向消防给水管网输送消防用水的预留接口。",[495,497,499,501],{"key":20,"text":496,"correct":22},"室内消火栓",{"key":24,"text":498,"correct":22},"室外消火栓",{"key":27,"text":500,"correct":22},"水鹤",{"key":31,"text":502,"correct":29},"消防水泵接合器",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":31,"analysis":33},963180,"下列建筑应设置室内消火栓系统的是（ ）。",[507,509,511,513],{"key":20,"text":508,"correct":22},"建筑占地面积为300㎡的厂房和仓库",{"key":24,"text":510,"correct":22},"建筑高度为21m的住宅建筑",{"key":27,"text":512,"correct":22},"设置有800个座位的剧场",{"key":31,"text":514,"correct":29},"某办公建筑地上3层建筑高度为15m，每层建筑面积2000㎡",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":31,"analysis":33},963181,"下列场所应设排烟系统的是（ ）。",[519,521,523,525],{"key":20,"text":520,"correct":22},"建筑面积为5000m2的丁类生产车间",{"key":24,"text":522,"correct":22},"占地面积为1000m2的丙类仓库",{"key":27,"text":524,"correct":22},"公共建筑内建筑面积为100m2且经常有人停留的地上房间",{"key":31,"text":526,"correct":29},"设置在四层的歌舞娱乐放映游艺场所每个房间的建筑面积均不大于100㎡",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":24,"analysis":33},963182,"下列不属于水基型灭火器的是（ ）。",[531,533,535,536],{"key":20,"text":532,"correct":22},"清水灭火器",{"key":24,"text":534,"correct":29},"二氧化碳灭火器",{"key":27,"text":57,"correct":22},{"key":31,"text":51,"correct":22},{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":27,"analysis":33},963183,"在最高使用温度条件下，不同的灭火器，对有效喷射时间的要求也不同，但必须满足不得低于（ ）。",[541,543,545,547],{"key":20,"text":542,"correct":22},"3s",{"key":24,"text":544,"correct":22},"5s",{"key":27,"text":546,"correct":29},"6s",{"key":31,"text":548,"correct":22},"8s",[550,553,556,559,562,565],{"id":15,"name":551,"category":7,"favorite":552},"领导干部任职前廉政法规知识测试题",92,{"id":554,"name":555,"category":7,"favorite":15},595,"建筑结构与设备",{"id":557,"name":558,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":560,"name":561,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":563,"name":564,"category":7,"favorite":8},534,"BIM工程师",{"id":566,"name":564,"category":7,"favorite":8},535]