[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-35":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":526},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,35,50,2862,[13,34,46,57,69,81,93,105,116,126,138,150,162,174,186,198,210,222,240,254,269,284,298,313,327,340,354,368,382,396,406,412,418,424,430,436,442,448,454,460,466,472,478,484,490,496,502,508,514,520],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},963034,1,"单选题","指在规定时间内，向防护区喷射设计规定用量气体灭火剂，并使用其均匀地充满整个防护区的气体灭火系统的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","管网灭火系统",false,{"key":24,"text":25,"correct":22},"B","预制灭火系统",{"key":27,"text":28,"correct":22},"C","局部应用气体灭火系统",{"key":30,"text":31,"correct":32},"D","全淹没气体灭火系统",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":30,"analysis":33},963035,"七氟丙烷灭火器系统适用于扑救（ ）火灾。",[38,40,42,44],{"key":20,"text":39,"correct":22},"钾",{"key":24,"text":41,"correct":22},"氢化钠",{"key":27,"text":43,"correct":22},"硝酸钠",{"key":30,"text":45,"correct":32},"沥青",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},963036,"下列气体灭火系统不属于按照使用灭火剂分类的是（ ）。",[50,52,53,55],{"key":20,"text":51,"correct":22},"二氧化碳灭火系统",{"key":24,"text":25,"correct":32},{"key":27,"text":54,"correct":22},"七氟丙烷灭火系统",{"key":30,"text":56,"correct":22},"惰性气体灭火系统",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":27,"analysis":33},963037,"下列不属于雨淋系统使用范围的是（ ）。",[61,63,65,67],{"key":20,"text":62,"correct":22},"火灾水平蔓延速度快、闭式洒水喷头的开放不能及时使喷水有效覆盖着小区域的场所",{"key":24,"text":64,"correct":22},"室内净空高度超过闭式系统最大允许净空高度，且必须迅速扑救初期火灾的场所",{"key":27,"text":66,"correct":32},"灭火后必须停止喷水的场所",{"key":30,"text":68,"correct":22},"严重危险级Ⅱ级的场所",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":30,"analysis":33},963038,"气体灭火系统一般具有自动控制、手动控制、机械应急操作三种启动方式。预制灭火系统应设（ ）启动方式。",[73,75,77,79],{"key":20,"text":74,"correct":22},"自动控制",{"key":24,"text":76,"correct":22},"手动控制",{"key":27,"text":78,"correct":22},"机械应急操作",{"key":30,"text":80,"correct":32},"自动控制和手动控制",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},963039,"气体灭火系统防护区应能在（ ）内使该区域人员疏散完毕的走道与出口，在疏散走道与出口处，应设火灾事故照明和疏散指示标志。",[85,87,89,91],{"key":20,"text":86,"correct":22},"15s",{"key":24,"text":88,"correct":32},"30s",{"key":27,"text":90,"correct":22},"45s",{"key":30,"text":92,"correct":22},"60s",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":30,"analysis":33},963040,"下列属于轻危险级的场所是（ ）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"食品生产车间",{"key":24,"text":100,"correct":22},"印刷厂",{"key":27,"text":102,"correct":22},"胶合板工厂",{"key":30,"text":104,"correct":32},"幼儿园",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":30,"analysis":33},963041,"下列属于中危险级的场所是（ ）。",[109,110,112,114],{"key":20,"text":104,"correct":22},{"key":24,"text":111,"correct":22},"养老院",{"key":27,"text":113,"correct":22},"住宅",{"key":30,"text":115,"correct":32},"高层民用建筑",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":27,"analysis":33},963042,"按一定的应用条件，将灭火剂储存装置和喷放装置组件等预先设计、组装成套且具有联动控制功能的灭火系统属于（ ）。",[120,121,123,124],{"key":20,"text":21,"correct":22},{"key":24,"text":122,"correct":22},"独立单元灭火系统",{"key":27,"text":25,"correct":32},{"key":30,"text":125,"correct":22},"热气溶胶灭火系统",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},963043,"对于应设置雨淋自动喷水灭火系统的置或部位，以下描述不正确的是（ ）。",[130,132,134,136],{"key":20,"text":131,"correct":22},"火柴厂的氯酸钾压碾厂房",{"key":24,"text":133,"correct":32},"月装瓶量大于3000瓶的液化石油气储配站的灌瓶间",{"key":27,"text":135,"correct":22},"500m2的演播室",{"key":30,"text":137,"correct":22},"甲级剧场",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":27,"analysis":33},963044,"下列不宜采用自动喷火灭火系统的是（ ）",[142,144,146,148],{"key":20,"text":143,"correct":22},"占地面积大于1500m2的木器厂房",{"key":24,"text":145,"correct":22},"每座占在面积大于600m2的火柴仓库",{"key":27,"text":147,"correct":32},"中央档案馆内的珍藏库",{"key":30,"text":149,"correct":22},"置高度大于100m的住宅置",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":20,"analysis":33},963045,"二氧化碳灭火系统地下防护区和无窗或固定窗扇的地上防护区，应设（ ）。",[154,156,158,160],{"key":20,"text":155,"correct":32},"机械排风装置",{"key":24,"text":157,"correct":22},"疏散指示标志",{"key":27,"text":159,"correct":22},"防烟装置",{"key":30,"text":161,"correct":22},"水喷雾装置",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":33},963046,"气体灭火系统分为全淹没气体灭火系统和局部应用气体灭火系统分类，属于按（ ）。",[166,168,170,172],{"key":20,"text":167,"correct":32},"按应用方式",{"key":24,"text":169,"correct":22},"按装配形式",{"key":27,"text":171,"correct":22},"按结构特点",{"key":30,"text":173,"correct":22},"按加压方式",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},963047,"具有灭火能力强、全球温室效应潜能值小、臭氧层损耗能力为零、不会破坏大气环境、灭火后无残留物等特点，是指（ ）灭火剂。",[178,180,182,184],{"key":20,"text":179,"correct":22},"二氧化碳",{"key":24,"text":181,"correct":32},"七氟丙烷",{"key":27,"text":183,"correct":22},"IG541",{"key":30,"text":185,"correct":22},"IG100",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":30,"analysis":33},963048,"下列关于气体灭火系统防火区的设置说法不正确的是（ ）。",[190,192,194,196],{"key":20,"text":191,"correct":22},"防护区宜以单个封闭空间划分",{"key":24,"text":193,"correct":22},"采用管网灭火系统时，一个防护区面积不宜大于800㎡，且容积不宜大于3600m3",{"key":27,"text":195,"correct":22},"采用预制灭火系统时，一个防护区面积不宜大于500㎡，且容积不宜大于1600m3",{"key":30,"text":197,"correct":32},"同一区间的吊顶层和地板下需同时保护时，应分别设置防护区",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},963049,"采用局部应用二氧化碳灭火系统的保护对象，应符合下列规定：保护对象周围的空气流动速度不宜大于（ ）m\u002Fs，必要时应采取挡风措施；在喷头与保护对象之间，喷头喷射角范围内不应有遮挡物；当保护对象为可燃液体时，液面至容器缘口的距离不得小于（ ）mm。",[202,204,206,208],{"key":20,"text":203,"correct":32},"3；150",{"key":24,"text":205,"correct":22},"3；200",{"key":27,"text":207,"correct":22},"4；250",{"key":30,"text":209,"correct":22},"5；350",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":27,"analysis":33},963050,"气体灭火系统防护区的最低环境温度不应低于（ ）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"-5℃",{"key":24,"text":217,"correct":22},"-8℃",{"key":27,"text":219,"correct":32},"-10℃",{"key":30,"text":221,"correct":22},"-12℃",{"id":223,"libraryId":5,"type":224,"typeLabel":225,"stem":226,"options":227,"answer":239,"analysis":33},963051,2,"多选题","下列场中应设置自动喷水灭火系统的有（ ）。",[228,230,232,234,236],{"key":20,"text":229,"correct":22},"占地面积为1500m2的木器厂房。",{"key":24,"text":231,"correct":32},"高层丙类厂房",{"key":27,"text":233,"correct":32},"建筑高度为32m的医疗建筑",{"key":30,"text":235,"correct":22},"建筑面积为500㎡的地下丙类厂房",{"key":237,"text":238,"correct":22},"E","建筑高度60m的住宅建筑","BC",{"id":241,"libraryId":5,"type":224,"typeLabel":225,"stem":242,"options":243,"answer":253,"analysis":33},963052,"下列场所应采用预作用自动喷水灭火系统的有（ ）。",[244,246,248,250,252],{"key":20,"text":245,"correct":32},"系统处于准工作状态时严禁误喷的场所",{"key":24,"text":247,"correct":32},"系统处于准工作状态时严禁管道充水的场所",{"key":27,"text":249,"correct":32},"用于替代干式系统的场所",{"key":30,"text":251,"correct":22},"火灾的水平蔓延速度快、闭式洒水喷头的开放不能及时使喷水有效覆盖着火区域的场所",{"key":237,"text":64,"correct":22},"ABC",{"id":255,"libraryId":5,"type":224,"typeLabel":225,"stem":256,"options":257,"answer":268,"analysis":33},963053,"下列属于湿式自动喷水灭火系统主要组成部分的有（ ）。",[258,260,262,264,266],{"key":20,"text":259,"correct":32},"闭式喷头",{"key":24,"text":261,"correct":32},"湿式报警阀组",{"key":27,"text":263,"correct":22},"供气设备",{"key":30,"text":265,"correct":32},"水流指示器",{"key":237,"text":267,"correct":32},"末端试水装置","ABDE",{"id":270,"libraryId":5,"type":224,"typeLabel":225,"stem":271,"options":272,"answer":283,"analysis":33},963054,"下列关于预作用自动喷水灭火系统的工作原理说法正确的有（ ）。",[273,275,277,279,281],{"key":20,"text":274,"correct":22},"在准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持管道内充水的压力",{"key":24,"text":276,"correct":22},"启动时，喷头爆破，系统侧（沿供水方向，报警阀后为系统侧，下同）压力下降，造成报警阀水源侧（沿供水方向，报警阀前为水源侧，下同）压力大于系统侧压力，报警阀被自动打开",{"key":27,"text":278,"correct":32},"系统处于准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持水源侧管道内充水的压力，系统侧管道内平时无水或充以有压气体。",{"key":30,"text":280,"correct":32},"火灾时，当触发同一报警区域内两个及以上独立的感烟探测器或一个感烟探测器与一个手动报警按钮时，联动开启阀组，使系统在闭式喷头动作前转换成湿式系统，并在闭式喷头开启后立即喷水。",{"key":237,"text":282,"correct":32},"当系统设有快速排气装置时，应联动控制排气阀前的电动阀开启。","CDE",{"id":285,"libraryId":5,"type":224,"typeLabel":225,"stem":286,"options":287,"answer":297,"analysis":33},963055,"下列关于干式自动喷水灭火系统的工作原理说法正确的有（ ）。",[288,290,292,294,295],{"key":20,"text":289,"correct":32},"在准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持水源侧管道内充水的压力，系统侧管道内充满有压气体（通常采用压缩空气）报警阀处于关闭状态；",{"key":24,"text":291,"correct":32},"发生火灾时，闭式喷头受热开启，管道中的有压气体从喷头喷出，报警阀系统侧压力下降，造成干式报警阀水源侧压力大于系统侧压力，干式报警阀被自动打开，压力水进入供水管道，将剩余压缩空气从系统立管顶端或横干管最高处的排气阀或已打开的喷头处喷出，然后喷水灭火；",{"key":27,"text":293,"correct":32},"消防水箱出水管上的流量开关、消防水泵出水管上的压力开关或报警阀组的压力开关动作并输出启动消防水泵信号，完成系统的启动；",{"key":30,"text":282,"correct":22},{"key":237,"text":296,"correct":32},"系统启动后，由消防水泵向开放的喷头供水，开放的喷头将供水按不低于设计规定的喷水强度均匀喷洒，实施灭火。","ABCE",{"id":299,"libraryId":5,"type":224,"typeLabel":225,"stem":300,"options":301,"answer":312,"analysis":33},963056,"下列关于雨淋系统的工作原理说法正确的有（ ）。",[302,304,306,308,310],{"key":20,"text":303,"correct":32},"雨淋系统处于准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持水源侧管道内充水的压力。",{"key":24,"text":305,"correct":32},"当保护区域内发生火情时，火灾自动报警系统联动开启电磁阀泄压或传动管上的洒水喷头动作泄压，使控制腔内压力迅速降低，供水侧与控制腔内压力形成压差，阀瓣组件瞬间开启，供水侧的水流入系统侧管网上的洒水喷头供水灭火，其中少部分的水流向水力警铃及压力开关，水力警铃发出连续的报警声，压力开关动作将信号反馈至消防控",{"key":27,"text":307,"correct":22},"在火灾停止后系统自动停止喷水",{"key":30,"text":309,"correct":22},"系统充满压力的水，当火灾现场的温度升高手喷头破碎，启动系统",{"key":237,"text":311,"correct":22},"火场温度恢复至常温时，探测器发出关停系统的信号，在按设定条件延迟喷水一段时间后，关闭雨淋报警阀，停止喷水。","AB",{"id":314,"libraryId":5,"type":224,"typeLabel":225,"stem":315,"options":316,"answer":297,"analysis":33},963057,"下列适用二氧化碳灭火系统扑救的有（ ）。",[317,319,321,323,325],{"key":20,"text":318,"correct":32},"灭火前可切断气源的气体火灾",{"key":24,"text":320,"correct":32},"液体火灾或石蜡、沥青等可熔化的固体火灾",{"key":27,"text":322,"correct":32},"固体表面火灾及棉毛、织物、纸张等部分固体深位火灾，",{"key":30,"text":324,"correct":22},"硝化纤维、火药等含氧化剂的化学制品火灾，钾、钠、镁、钛、锆等活泼金属火灾，氰化钾、氰化钠等金属氰化物火灾",{"key":237,"text":326,"correct":32},"电气火灾",{"id":328,"libraryId":5,"type":224,"typeLabel":225,"stem":329,"options":330,"answer":253,"analysis":33},963058,"下列适用于七氟丙烷灭火系统扑救的有（ ）。",[331,332,334,336,338],{"key":20,"text":326,"correct":32},{"key":24,"text":333,"correct":32},"液体火灾或可熔化的固体火灾",{"key":27,"text":335,"correct":32},"固体表面火灾，灭火前应能切断气源的气体火灾",{"key":30,"text":337,"correct":22},"硝化纤维、硝酸钠等含氧化剂的化学制品及混合物火灾",{"key":237,"text":339,"correct":22},"钾、钠、镁、钛、锆、铀等活泼金属火灾，氢化钾、氢化钠等金属氢化物火灾，过氧化氢、联胺等能自行分解的化学物质火灾",{"id":341,"libraryId":5,"type":224,"typeLabel":225,"stem":342,"options":343,"answer":353,"analysis":33},963059,"下列适用于全淹没气体灭火系统的有（ ）。",[344,346,347,349,351],{"key":20,"text":345,"correct":32},"灭火前能切断气源的气体火灾",{"key":24,"text":326,"correct":32},{"key":27,"text":348,"correct":32},"固体表面火灾",{"key":30,"text":350,"correct":32},"液体火灾",{"key":237,"text":352,"correct":22},"硝酸钠、硝化纤维等氧化剂或氧化剂的化学制品火灾","ABCD",{"id":355,"libraryId":5,"type":224,"typeLabel":225,"stem":356,"options":357,"answer":312,"analysis":33},963060,"下列场所适用于局部应用气体灭火系统的有（ ）。",[358,360,362,364,366],{"key":20,"text":359,"correct":32},"非封闭的自动生产线",{"key":24,"text":361,"correct":32},"非封闭的货物传送带",{"key":27,"text":363,"correct":22},"电子机房",{"key":30,"text":365,"correct":22},"小型重要单据房",{"key":237,"text":367,"correct":22},"文件仓库",{"id":369,"libraryId":5,"type":224,"typeLabel":225,"stem":370,"options":371,"answer":353,"analysis":33},963061,"下列关于气体灭火防护区的安全设置符合要求的有（ ）。",[372,374,376,378,380],{"key":20,"text":373,"correct":32},"防护区应有保证人员在30s内疏散完毕的通道和出口；",{"key":24,"text":375,"correct":32},"防护区内的疏散通道及出口，应设应急照明与疏散指示标志；",{"key":27,"text":377,"correct":32},"防护区内应设火灾声报警器；防护区入口处应设火灾声、光报警器和灭火剂喷放指示灯，以及防护区采用的相应气体灭火系统的永久性标志牌；",{"key":30,"text":379,"correct":32},"防护区的门应向疏散方向开启，并能自行关闭；地下防护区和无窗或设固定窗扇的地上防护区，应设置机械排风装置。",{"key":237,"text":381,"correct":22},"气体灭火防护区内的应具最低的防护抗压等级，围护结构抗压等级不能低于1500Pa",{"id":383,"libraryId":5,"type":224,"typeLabel":225,"stem":384,"options":385,"answer":253,"analysis":33},963062,"下列关于防护区开口的设置说法符合规范规定的有（ ）",[386,388,390,392,394],{"key":20,"text":387,"correct":32},"防护区开口的设置，为防止灭火剂流失，防护区的围护构件上不宜设置敞开孔洞",{"key":24,"text":389,"correct":32},"当必须设置敞开孔洞时，应设置能手动和自动关闭装置",{"key":27,"text":391,"correct":32},"喷放灭火剂前，防护区内除泄压口外的开口应能自行关闭",{"key":30,"text":393,"correct":22},"采用全淹没二氧化碳灭火系统扑救气体、液体、电气火灾和固体表面火灾时，在喷放二氧化碳前不能自动关闭的开口，其面积不应大于防护区总内表面积的5%，且开口不应设在底面",{"key":237,"text":395,"correct":22},"启动释放气体灭火剂之后，必须切断可燃、助燃气体的气源",{"id":397,"libraryId":5,"type":398,"typeLabel":399,"stem":400,"options":401,"answer":405,"analysis":33},963063,3,"判断题","湿式系统是指发生火灾时管道内充满用于启动系统的有压水的开式系统。",[402,404],{"key":20,"text":403,"correct":22},"正确",{"key":24,"text":405,"correct":32},"错误",{"id":407,"libraryId":5,"type":398,"typeLabel":399,"stem":408,"options":409,"answer":405,"analysis":33},963064,"湿式系统由开式喷头、湿式报警阀组、管道系统、报警控制装置组成。",[410,411],{"key":20,"text":403,"correct":22},{"key":24,"text":405,"correct":32},{"id":413,"libraryId":5,"type":398,"typeLabel":399,"stem":414,"options":415,"answer":405,"analysis":33},963065,"干式系统是指准工作状态时配水管道内充满用于启动系统的有压水的闭式系统。",[416,417],{"key":20,"text":403,"correct":22},{"key":24,"text":405,"correct":32},{"id":419,"libraryId":5,"type":398,"typeLabel":399,"stem":420,"options":421,"answer":403,"analysis":33},963066,"预作用系统是指准工作状态时配水道内不充水，发生火灾时由火灾自动报警系统、充气管道上的压力开关联锁控制预使用装置和启动消防水泵向配水管道供水，喷头受热开放后喷水灭火",[422,423],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":425,"libraryId":5,"type":398,"typeLabel":399,"stem":426,"options":427,"answer":403,"analysis":33},963067,"水幕系统是指由开式洒水喷头或水幕喷头、雨淋阀组或感温雨淋阀，以及水流报警装置（水流指示器或压力开关）等组成，用于挡烟阻火和冷却分隔物的喷水系统。",[428,429],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":431,"libraryId":5,"type":398,"typeLabel":399,"stem":432,"options":433,"answer":403,"analysis":33},963068,"预制灭火系统分为柜式预制灭火系统和悬挂式预制灭火系统两种类型。",[434,435],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":437,"libraryId":5,"type":398,"typeLabel":399,"stem":438,"options":439,"answer":403,"analysis":33},963069,"水喷雾灭火系统的水雾喷头在较高的水压力作用下，将水流分离成0.2-2mm甚至更小的细小水雾滴，通过表面冷却、窒息、稀释、冲击乳化和覆盖等作用实现灭火。",[440,441],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":443,"libraryId":5,"type":398,"typeLabel":399,"stem":444,"options":445,"answer":403,"analysis":33},963070,"液上喷射泡沫灭火系统与液下喷射泡沫灭火系统相比，具有泡沫不受污染，可以使用廉价的普通蛋白泡沫等优点。",[446,447],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":449,"libraryId":5,"type":398,"typeLabel":399,"stem":450,"options":451,"answer":405,"analysis":33},963071,"雨淋系统主要有闭式喷头、雨淋阀启动装置、雨淋阀组、管道及供水设施等组成。",[452,453],{"key":20,"text":403,"correct":22},{"key":24,"text":405,"correct":32},{"id":455,"libraryId":5,"type":398,"typeLabel":399,"stem":456,"options":457,"answer":403,"analysis":33},963072,"根据自动喷水灭火系统的设置场所危险等级划分，家用电器仓库属于仓库火灾危险Ⅱ级场所。",[458,459],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":461,"libraryId":5,"type":398,"typeLabel":399,"stem":462,"options":463,"answer":403,"analysis":33},963073,"根据自动喷水灭火系统的设置场所危险等级划分，建筑高度24m的旅馆属于轻危险级。",[464,465],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":467,"libraryId":5,"type":398,"typeLabel":399,"stem":468,"options":469,"answer":403,"analysis":33},963074,"严重危险Ⅱ级一般是指易燃液体喷雾操作区域、固体易燃物品、可燃的气溶胶制品、溶剂清洗、喷涂油漆、沥青制品等工厂的备料及生产车间、摄影棚、舞台葡萄架下部等。",[470,471],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":473,"libraryId":5,"type":398,"typeLabel":399,"stem":474,"options":475,"answer":405,"analysis":33},963075,"预作用系统处于准工作状态时，由消防水箱或稳压泵、气压给水设备等稳压设施维持管道内的充水压力。",[476,477],{"key":20,"text":403,"correct":22},{"key":24,"text":405,"correct":32},{"id":479,"libraryId":5,"type":398,"typeLabel":399,"stem":480,"options":481,"answer":405,"analysis":33},963076,"预作用系统系统采用一种既可输出火警信号，又可在环境恢复常温时输出灭火信号的感温探测器。",[482,483],{"key":20,"text":403,"correct":22},{"key":24,"text":405,"correct":32},{"id":485,"libraryId":5,"type":398,"typeLabel":399,"stem":486,"options":487,"answer":403,"analysis":33},963077,"水幕系统由开式喷头或水幕喷头、雨淋报警阀组或感温雨淋报警阀组等组成，分为防火分隔水幕和防护冷却水幕两种。",[488,489],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":491,"libraryId":5,"type":398,"typeLabel":399,"stem":492,"options":493,"answer":403,"analysis":33},963078,"压缩空气泡沫灭火系统是一种新型泡沫灭火系统，是在密闭管路中将水、泡沫液和压缩空气按照设定的混合比、气液比混合生成均质压缩空气泡沫的灭火系统。",[494,495],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":497,"libraryId":5,"type":398,"typeLabel":399,"stem":498,"options":499,"answer":405,"analysis":33},963079,"局部应用二氧化碳灭火系统保护对象周围的空气流动速度不宜大于5m\u002Fs，必要时应采取挡风措施。",[500,501],{"key":20,"text":403,"correct":22},{"key":24,"text":405,"correct":32},{"id":503,"libraryId":5,"type":398,"typeLabel":399,"stem":504,"options":505,"answer":403,"analysis":33},963080,"气体灭火系统防护区的最低环境温度不应低于-10℃。",[506,507],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":509,"libraryId":5,"type":398,"typeLabel":399,"stem":510,"options":511,"answer":403,"analysis":33},963081,"泡沫喷雾系统适用于独立变电站的油浸电力变压器：面积不大于200m2的非水溶性液体室内场所",[512,513],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":515,"libraryId":5,"type":398,"typeLabel":399,"stem":516,"options":517,"answer":403,"analysis":33},963082,"气体灭火系统是以气体为主要灭火介质的灭火系统，通过这些气体在整个防护区或保护对象周围的局部区域建立起灭火浓度实现灭火。",[518,519],{"key":20,"text":403,"correct":32},{"key":24,"text":405,"correct":22},{"id":521,"libraryId":5,"type":398,"typeLabel":399,"stem":522,"options":523,"answer":405,"analysis":33},963083,"气体灭火系统按装配形式可分为：组合分配灭火系统和单元独立灭火系统。",[524,525],{"key":20,"text":403,"correct":22},{"key":24,"text":405,"correct":32},[527,530,533,536,539,542],{"id":15,"name":528,"category":7,"favorite":529},"领导干部任职前廉政法规知识测试题",92,{"id":531,"name":532,"category":7,"favorite":15},595,"建筑结构与设备",{"id":534,"name":535,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":537,"name":538,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":540,"name":541,"category":7,"favorite":8},534,"BIM工程师",{"id":543,"name":541,"category":7,"favorite":8},535]