[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":533},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,27,50,2862,[13,28,34,40,46,52,67,75,83,95,107,119,131,139,151,163,175,193,199,205,211,226,238,250,262,274,286,294,302,314,326,334,346,358,370,382,390,398,406,418,430,442,452,461,471,480,492,504,515,523],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},962632,3,"判断题","某多层办公楼，建筑高度20m，采用外墙内保温系统时，选用了B1级的保温材料，其防护层的厚度不应小于20mm。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},962633,"建筑高度为28m的住宅建筑，采用B1级外保温材料，与基层墙体、装饰层之间无空腔，外墙上门、窗的耐火完整性为0.25h。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},962634,"对于人员密集场所及各类建筑的疏散楼梯间，应采用燃烧性能不低于B1级的保温材料。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},962635,"建筑外保温材料的燃烧性能宜为A级，且不应低于B1级。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":25,"analysis":27},962636,"建筑高度80m的某星级酒店，建筑外墙采用难燃仿花岗岩装饰板装饰。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":54,"typeLabel":55,"stem":56,"options":57,"answer":20,"analysis":27},962637,1,"单选题","某办公建筑封闭楼梯间的顶棚、墙面和地面均应采用（ ）级装修材料。",[58,59,61,64],{"key":20,"text":20,"correct":26},{"key":24,"text":60,"correct":22},"B1",{"key":62,"text":63,"correct":22},"C","B2",{"key":65,"text":66,"correct":22},"D","B3",{"id":68,"libraryId":5,"type":54,"typeLabel":55,"stem":69,"options":70,"answer":20,"analysis":27},962638,"某养老院，建筑高度18m，在进行内部装修时，建筑内顶棚装饰材料的燃烧性能等级应为（ ）级。",[71,72,73,74],{"key":20,"text":20,"correct":26},{"key":24,"text":60,"correct":22},{"key":62,"text":63,"correct":22},{"key":65,"text":66,"correct":22},{"id":76,"libraryId":5,"type":54,"typeLabel":55,"stem":77,"options":78,"answer":24,"analysis":27},962639,"建筑的屋面外保温系统，当屋面板耐火极限低于1.0h，保温材料的燃烧性能不应低于（ ）级。",[79,80,81,82],{"key":20,"text":20,"correct":22},{"key":24,"text":60,"correct":26},{"key":62,"text":63,"correct":22},{"key":65,"text":66,"correct":22},{"id":84,"libraryId":5,"type":54,"typeLabel":55,"stem":85,"options":86,"answer":20,"analysis":27},962640,"下列关于与基层墙体、装饰层之间无空腔且每层设置防火隔离带的建筑外墙外保温系统的做法中不符合规范规定的是（ ）。",[87,89,91,93],{"key":20,"text":88,"correct":26},"建筑高度为24m的住宅建筑，采用B2级保温材料，外墙上门、窗的耐火完整性为0.25h",{"key":24,"text":90,"correct":22},"建筑高度为24m的办公建筑，采用B1级保温材料，外墙上门、窗的耐火完整性为0.25h",{"key":62,"text":92,"correct":22},"建筑高度为66m的住宅建筑，采用B1级保温材料，外墙上门、窗的耐火完整性为0.50h",{"key":65,"text":94,"correct":22},"建筑高度为50m的办公建筑，采用B1级保温材料，外墙上门、窗的耐火完整性为0.50h",{"id":96,"libraryId":5,"type":54,"typeLabel":55,"stem":97,"options":98,"answer":24,"analysis":27},962641,"下列关于地下商店营业厅的内部装修材料中，可以采用B1级燃烧性能的是（ ）。",[99,101,103,105],{"key":20,"text":100,"correct":22},"地面装修材料",{"key":24,"text":102,"correct":26},"装饰织物",{"key":62,"text":104,"correct":22},"售货柜台、固定货架",{"key":65,"text":106,"correct":22},"墙面装修材料",{"id":108,"libraryId":5,"type":54,"typeLabel":55,"stem":109,"options":110,"answer":65,"analysis":27},962642,"下列墙面装修材料中与其他墙面装修材料不一样的是（ ）。",[111,113,115,117],{"key":20,"text":112,"correct":22},"塑料贴面装饰板",{"key":24,"text":114,"correct":22},"纸制装饰板",{"key":62,"text":116,"correct":22},"无纺贴墙布",{"key":65,"text":118,"correct":26},"纸面石膏板",{"id":120,"libraryId":5,"type":54,"typeLabel":55,"stem":121,"options":122,"answer":24,"analysis":27},962643,"下列场所的内部装修应全部使用A级装修材料的是（ ）。",[123,125,127,129],{"key":20,"text":124,"correct":22},"消防控制室",{"key":24,"text":126,"correct":26},"排烟机房",{"key":62,"text":128,"correct":22},"档案室",{"key":65,"text":130,"correct":22},"会议室",{"id":132,"libraryId":5,"type":54,"typeLabel":55,"stem":133,"options":134,"answer":20,"analysis":27},962644,"某医疗建筑，地上5层，建筑高度23m，采用外墙内保温系统时，保温材料最低选用（ ）。",[135,136,137,138],{"key":20,"text":20,"correct":26},{"key":24,"text":60,"correct":22},{"key":62,"text":63,"correct":22},{"key":65,"text":66,"correct":22},{"id":140,"libraryId":5,"type":54,"typeLabel":55,"stem":141,"options":142,"answer":20,"analysis":27},962645,"某歌舞娱乐场所设置在耐火等级为二级的多层建筑的5层，室内装修的顶棚材料应采用（ ）级，地面应采用不低于（ ）级的装修材料。",[143,145,147,149],{"key":20,"text":144,"correct":26},"A；B1",{"key":24,"text":146,"correct":22},"A；B2",{"key":62,"text":148,"correct":22},"B1；B2",{"key":65,"text":150,"correct":22},"B2；B1",{"id":152,"libraryId":5,"type":54,"typeLabel":55,"stem":153,"options":154,"answer":24,"analysis":27},962646,"建筑内部的配电箱不应直接安装在低于（ ）级的装修材料上。",[155,157,159,161],{"key":20,"text":156,"correct":22},"A级",{"key":24,"text":158,"correct":26},"B1级",{"key":62,"text":160,"correct":22},"B2级",{"key":65,"text":162,"correct":22},"B3级",{"id":164,"libraryId":5,"type":54,"typeLabel":55,"stem":165,"options":166,"answer":65,"analysis":27},962647,"装修材料按其燃烧性能应划分为（ ）级。",[167,169,171,173],{"key":20,"text":168,"correct":22},"七",{"key":24,"text":170,"correct":22},"六",{"key":62,"text":172,"correct":22},"五",{"key":65,"text":174,"correct":26},"四",{"id":176,"libraryId":5,"type":177,"typeLabel":178,"stem":179,"options":180,"answer":192,"analysis":27},962648,2,"多选题","某10层住宅建筑层高为30m。外保温体系与基层墙体无空腔，对该住宅外墙进行保温设计，选用的保温方式和材料中，符合规范要求的有（ ）。",[181,183,185,187,189],{"key":20,"text":182,"correct":22},"保温材料采用燃烧性能为B1级的胶粉聚苯颗粒保温浆料",{"key":24,"text":184,"correct":26},"保温材料采用燃烧性能为A级的泡沬玻璃板",{"key":62,"text":186,"correct":26},"保温材料采用燃烧性能为A级水泥发泡保温板",{"key":65,"text":188,"correct":26},"保温材料采用燃烧性能为B1级的胶粉聚苯颗粒保温浆料，每层设置防火隔离带",{"key":190,"text":191,"correct":22},"E","保温材料采用燃烧性能为B2级的聚苯乙烯泡沫塑料，每层设置防火隔离带","BCD",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":25,"analysis":27},962649,"建筑高度18m的展览建筑，保温层与基层墙体、装饰层之间无空腔，选用燃烧性能为B1级的外保温材料。",[197,198],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":25,"analysis":27},962650,"当建筑的屋面与外墙保温系统均采用B1、B2级保温材料时，屋面与外墙之间应采用宽度不小于50mm的不燃材料设置防火隔离带进行分隔。",[203,204],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":25,"analysis":27},962651,"一栋20层的旅馆，设有两个无外窗防烟楼梯间，且每层设有一条长42m、宽1.5m的无自然采光和通风的内走道。该建筑内走道顶棚装饰材料应采用B1级装修材料，内走道其他部位应采用不低于B2级的装修材料。",[209,210],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":212,"libraryId":5,"type":177,"typeLabel":178,"stem":213,"options":214,"answer":225,"analysis":27},962652,"下列常用建筑内部装修材料燃烧性能属于B1级顶棚材料的有（ ）。",[215,217,219,221,223],{"key":20,"text":216,"correct":22},"仿金属纹木制人造板",{"key":24,"text":218,"correct":26},"水泥刨花板",{"key":62,"text":220,"correct":26},"矿棉装饰吸声板",{"key":65,"text":222,"correct":22},"石膏板",{"key":190,"text":224,"correct":26},"珍珠岩装饰吸声板","BCE",{"id":227,"libraryId":5,"type":54,"typeLabel":55,"stem":228,"options":229,"answer":20,"analysis":27},962653,"下列关于与基层墙体、装饰层之间无空腔且每层设置防火隔离带的建筑外墙外 保温系统的做法中，错误的是()",[230,232,234,236],{"key":20,"text":231,"correct":26},"建筑高度为23.8m的住宅建筑，采用B2级保温材料，外墙上.门、窗的耐火或完整性为0.25h",{"key":24,"text":233,"correct":22},"建筑高度为48m的办公建筑，采用B1级保温材料，外墙上门、窗的耐火完整性为0.5h",{"key":62,"text":235,"correct":22},"建筑高度为70m的住宅建筑，采用B1级保温材料，外墙上门、窗的耐火完整性为0.5h",{"key":65,"text":237,"correct":22},"建筑高度为23.8m的办公建筑，采用B1级保温材料，外墙.门、窗的耐火完整性为0. 25h",{"id":239,"libraryId":5,"type":54,"typeLabel":55,"stem":240,"options":241,"answer":62,"analysis":27},962654,"竖向承重构件采用砖墙或砖柱，水平承重构件采用钢筋混凝土楼板、屋面板的建筑属于（）建筑。",[242,244,246,248],{"key":20,"text":243,"correct":22},"砖木结构",{"key":24,"text":245,"correct":22},"木结构",{"key":62,"text":247,"correct":26},"砖混结构",{"key":65,"text":249,"correct":22},"钢筋混凝土结构",{"id":251,"libraryId":5,"type":54,"typeLabel":55,"stem":252,"options":253,"answer":65,"analysis":27},962655,"工业建筑按生产和储存物品的火灾危险性分类可以分为（）类。",[254,256,258,260],{"key":20,"text":255,"correct":22},"甲、乙",{"key":24,"text":257,"correct":22},"甲、乙、丙",{"key":62,"text":259,"correct":22},"甲、乙、丙、丁",{"key":65,"text":261,"correct":26},"甲、乙、丙、丁、戊",{"id":263,"libraryId":5,"type":54,"typeLabel":55,"stem":264,"options":265,"answer":20,"analysis":27},962656,"依据《建筑材料及制品燃烧性能分级》（GB8624），A级材料指的是（）。",[266,268,270,272],{"key":20,"text":267,"correct":26},"不燃材料（制品）",{"key":24,"text":269,"correct":22},"难燃材料（制品）",{"key":62,"text":271,"correct":22},"普通可燃材料（制品）",{"key":65,"text":273,"correct":22},"易燃材料（制品）",{"id":275,"libraryId":5,"type":54,"typeLabel":55,"stem":276,"options":277,"answer":20,"analysis":27},962657,"不燃性构件是指用（）做成的构件。",[278,280,282,284],{"key":20,"text":279,"correct":26},"不燃材料",{"key":24,"text":281,"correct":22},"难燃材料",{"key":62,"text":283,"correct":22},"可燃材料",{"key":65,"text":285,"correct":22},"易燃材料",{"id":287,"libraryId":5,"type":54,"typeLabel":55,"stem":288,"options":289,"answer":24,"analysis":27},962658,"难燃性构件是指用（）做成的构件或用可燃材料做成而用非燃烧性材料做保护层的构件，如水泥刨花复合板隔墙、木龙骨两面钉石膏板隔墙等。",[290,291,292,293],{"key":20,"text":279,"correct":22},{"key":24,"text":281,"correct":26},{"key":62,"text":283,"correct":22},{"key":65,"text":285,"correct":22},{"id":295,"libraryId":5,"type":54,"typeLabel":55,"stem":296,"options":297,"answer":62,"analysis":27},962659,"可燃性构件是指用（）做成的构件，如木柱、木楼板、竹制吊顶等。",[298,299,300,301],{"key":20,"text":279,"correct":22},{"key":24,"text":281,"correct":22},{"key":62,"text":283,"correct":26},{"key":65,"text":285,"correct":22},{"id":303,"libraryId":5,"type":54,"typeLabel":55,"stem":304,"options":305,"answer":20,"analysis":27},962660,"（）是构件耐火极限主要的内在影响因素。",[306,308,310,312],{"key":20,"text":307,"correct":26},"材料本身的燃烧性能",{"key":24,"text":309,"correct":22},"材料的高温力学性能和导热性能",{"key":62,"text":311,"correct":22},"建筑构件的截面尺寸",{"key":65,"text":313,"correct":22},"保护层的厚度",{"id":315,"libraryId":5,"type":54,"typeLabel":55,"stem":316,"options":317,"answer":24,"analysis":27},962661,"二级耐火等级建筑是指主要建筑构件除吊顶为（），其余构件为不燃烧体，且满足相应耐火极限要求的建筑。",[318,320,322,324],{"key":20,"text":319,"correct":22},"不燃烧体",{"key":24,"text":321,"correct":26},"难燃烧体",{"key":62,"text":323,"correct":22},"可燃烧体",{"key":65,"text":325,"correct":22},"易燃烧体",{"id":327,"libraryId":5,"type":54,"typeLabel":55,"stem":328,"options":329,"answer":24,"analysis":27},962662,"三级耐火等级建筑是指主要构件除吊顶（包括吊顶搁栅）和房间隔墙可采用（）外，其余构件均为不燃烧体且满足相应耐火极限要求的建筑。",[330,331,332,333],{"key":20,"text":319,"correct":22},{"key":24,"text":321,"correct":26},{"key":62,"text":323,"correct":22},{"key":65,"text":325,"correct":22},{"id":335,"libraryId":5,"type":54,"typeLabel":55,"stem":336,"options":337,"answer":65,"analysis":27},962663,"以下属于三级耐火等级建筑的是（）。",[338,340,342,344],{"key":20,"text":339,"correct":22},"70m的住宅",{"key":24,"text":341,"correct":22},"38m的住宅",{"key":62,"text":343,"correct":22},"医疗建筑",{"key":65,"text":345,"correct":26},"木结构屋顶的砖木结构建筑",{"id":347,"libraryId":5,"type":54,"typeLabel":55,"stem":348,"options":349,"answer":20,"analysis":27},962664,"水平防火分区可采用防火墙、防火卷帘进行分隔：对于采用防火墙进行分隔的，防火墙上确需开设门、窗、洞口时应为（）防火门、窗。",[350,352,354,356],{"key":20,"text":351,"correct":26},"甲级",{"key":24,"text":353,"correct":22},"乙级",{"key":62,"text":355,"correct":22},"丙级",{"key":65,"text":357,"correct":22},"特级",{"id":359,"libraryId":5,"type":54,"typeLabel":55,"stem":360,"options":361,"answer":20,"analysis":27},962665,"建筑内设置自动灭火系统的防火分区最大允许建筑面积可按规定增加（）倍。局部设置时，防火分区的增加面积可按该局部面积的（）倍计算。",[362,364,366,368],{"key":20,"text":363,"correct":26},"1.0",{"key":24,"text":365,"correct":22},"2.0",{"key":62,"text":367,"correct":22},"3.0",{"key":65,"text":369,"correct":22},"4.0",{"id":371,"libraryId":5,"type":54,"typeLabel":55,"stem":372,"options":373,"answer":62,"analysis":27},962666,"防火墙是防止火灾蔓延至相邻建筑或相邻水平防火分区且耐火极限不低于（）h的不燃性墙体，是建筑水平防火分区的主要防火分隔物，由不燃烧材料构成。",[374,376,378,380],{"key":20,"text":375,"correct":22},"1.00",{"key":24,"text":377,"correct":22},"2.00",{"key":62,"text":379,"correct":26},"3.00",{"key":65,"text":381,"correct":22},"4.00",{"id":383,"libraryId":5,"type":54,"typeLabel":55,"stem":384,"options":385,"answer":65,"analysis":27},962667,"甲、乙类厂房和甲、乙、丙类仓库内的防火墙，其耐火极限不应低于（）h。",[386,387,388,389],{"key":20,"text":375,"correct":22},{"key":24,"text":377,"correct":22},{"key":62,"text":379,"correct":22},{"key":65,"text":381,"correct":26},{"id":391,"libraryId":5,"type":54,"typeLabel":55,"stem":392,"options":393,"answer":24,"analysis":27},962668,"附设在建筑内的消防控制室、灭火设备室、消防水泵房和通风空气调节机房、变配电室等，应采用耐火极限不低于（）h的防火隔墙。",[394,395,396,397],{"key":20,"text":375,"correct":22},{"key":24,"text":377,"correct":26},{"key":62,"text":379,"correct":22},{"key":65,"text":381,"correct":22},{"id":399,"libraryId":5,"type":54,"typeLabel":55,"stem":400,"options":401,"answer":62,"analysis":27},962669,"锅炉房、柴油发电机房内设置储油间时，应采用耐火极限不低于（）h的防火隔墙与储油间分隔。",[402,403,404,405],{"key":20,"text":375,"correct":22},{"key":24,"text":377,"correct":22},{"key":62,"text":379,"correct":26},{"key":65,"text":381,"correct":22},{"id":407,"libraryId":5,"type":54,"typeLabel":55,"stem":408,"options":409,"answer":24,"analysis":27},962670,"乙类厂房与明火或散发火花地点的防火间距不宜小于（）m。",[410,412,414,416],{"key":20,"text":411,"correct":22},"20",{"key":24,"text":413,"correct":26},"30",{"key":62,"text":415,"correct":22},"40",{"key":65,"text":417,"correct":22},"50",{"id":419,"libraryId":5,"type":54,"typeLabel":55,"stem":420,"options":421,"answer":62,"analysis":27},962671,"为丙、丁、戊类厂房服务而单独设置的生活用房应按民用建筑确定，与所属厂房的防火间距不应小于（）m。",[422,424,426,428],{"key":20,"text":423,"correct":22},"4",{"key":24,"text":425,"correct":22},"5",{"key":62,"text":427,"correct":26},"6",{"key":65,"text":429,"correct":22},"7",{"id":431,"libraryId":5,"type":54,"typeLabel":55,"stem":432,"options":433,"answer":62,"analysis":27},962672,"堆场之间的防火间距为两堆场中相邻堆垛外缘的（）水平距离。",[434,436,438,440],{"key":20,"text":435,"correct":22},"最高",{"key":24,"text":437,"correct":22},"最低",{"key":62,"text":439,"correct":26},"最近",{"key":65,"text":441,"correct":22},"最远",{"id":443,"libraryId":5,"type":54,"typeLabel":55,"stem":444,"options":445,"answer":65,"analysis":27},962673,"车道的净宽度和净空高度均不应小于（）m。",[446,448,449,451],{"key":20,"text":447,"correct":22},"2.5",{"key":24,"text":367,"correct":22},{"key":62,"text":450,"correct":22},"3.5",{"key":65,"text":369,"correct":26},{"id":453,"libraryId":5,"type":54,"typeLabel":55,"stem":454,"options":455,"answer":65,"analysis":27},962674,"消防车道靠建筑外墙一侧的边缘距离建筑外墙不宜小于（）m。",[456,457,459,460],{"key":20,"text":447,"correct":22},{"key":24,"text":458,"correct":22},"3",{"key":62,"text":450,"correct":22},{"key":65,"text":425,"correct":26},{"id":462,"libraryId":5,"type":54,"typeLabel":55,"stem":463,"options":464,"answer":62,"analysis":27},962675,"消防车道的坡度不宜大于（）%。",[465,466,467,469],{"key":20,"text":427,"correct":22},{"key":24,"text":429,"correct":22},{"key":62,"text":468,"correct":26},"8",{"key":65,"text":470,"correct":22},"9",{"id":472,"libraryId":5,"type":54,"typeLabel":55,"stem":473,"options":474,"answer":20,"analysis":27},962676,"医院和疗养院的住院部分采用三级耐火等级建筑时，不应超过（）层。",[475,477,478,479],{"key":20,"text":476,"correct":26},"2",{"key":24,"text":458,"correct":22},{"key":62,"text":423,"correct":22},{"key":65,"text":425,"correct":22},{"id":481,"libraryId":5,"type":54,"typeLabel":55,"stem":482,"options":483,"answer":20,"analysis":27},962677,"电梯从首层至顶层的运行时间不宜大于（）s。",[484,486,488,490],{"key":20,"text":485,"correct":26},"60",{"key":24,"text":487,"correct":22},"70",{"key":62,"text":489,"correct":22},"80",{"key":65,"text":491,"correct":22},"90",{"id":493,"libraryId":5,"type":54,"typeLabel":55,"stem":494,"options":495,"answer":62,"analysis":27},962678,"厂房内疏散走道的净宽度不宜小于（）m。",[496,498,500,502],{"key":20,"text":497,"correct":22},"1.2",{"key":24,"text":499,"correct":22},"1.3",{"key":62,"text":501,"correct":26},"1.4",{"key":65,"text":503,"correct":22},"1.5",{"id":505,"libraryId":5,"type":54,"typeLabel":55,"stem":506,"options":507,"answer":24,"analysis":27},962679,"公共建筑内疏散走道的净宽度不应小于（）m。",[508,509,511,513],{"key":20,"text":375,"correct":22},{"key":24,"text":510,"correct":26},"1.10",{"key":62,"text":512,"correct":22},"1.20",{"key":65,"text":514,"correct":22},"1.30",{"id":516,"libraryId":5,"type":54,"typeLabel":55,"stem":517,"options":518,"answer":20,"analysis":27},962680,"歌舞娱乐放映游艺场所设置在一、二级耐火等级建筑的四层及四层以上时，室内装修的顶棚材料应采用（）级装修材料。",[519,520,521,522],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":62,"text":24,"correct":22},{"key":65,"text":24,"correct":22},{"id":524,"libraryId":5,"type":54,"typeLabel":55,"stem":525,"options":526,"answer":24,"analysis":27},962681,"以下属于四级耐火等级建筑的是（）。",[527,529,531,532],{"key":20,"text":528,"correct":22},"60m的住宅",{"key":24,"text":530,"correct":26},"木柱、木屋架承重的建筑",{"key":62,"text":343,"correct":22},{"key":65,"text":345,"correct":22},[534,537,540,543,546,549],{"id":54,"name":535,"category":7,"favorite":536},"领导干部任职前廉政法规知识测试题",92,{"id":538,"name":539,"category":7,"favorite":54},595,"建筑结构与设备",{"id":541,"name":542,"category":7,"favorite":54},715,"招标采购专业知识与法律法规",{"id":544,"name":545,"category":7,"favorite":54},848,"市政方向-通用基础",{"id":547,"name":548,"category":7,"favorite":8},534,"BIM工程师",{"id":550,"name":548,"category":7,"favorite":8},535]