[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":529},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,26,50,2862,[13,28,34,40,46,52,58,74,86,98,110,122,134,142,154,165,177,189,201,219,234,249,255,261,267,273,279,291,305,315,324,335,344,356,368,380,392,404,416,429,444,459,474,487,493,499,505,511,517,523],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},962581,3,"判断题","当该场所设置自动喷水灭火系统时，室内任一点至最近安全出口的安全疏散距离可增加25%。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},962582,"疏散门是直接通向疏散走道的房间门、直接开向疏散楼梯间的门或室外的门，包括套间内的隔间门或住宅套内的房间门。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},962584,"疏散走道的布置应简明直接，设置尽量避免曲折和袋形走道，并按规定设置疏散指示标志和诱导灯。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},962585,"避难走道是指设置防烟设施且两侧采用防火墙分隔，用于人员安全通行至室外的走道。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},962586,"避难走道直通地面的出口不应少于2个，并应设置在不同方向；当避难走道仅与一个防火分区相通且该防火分区至少有1个直通室外的安全出口时，可设置1个直通地面的出口。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},962587,"防火隔间只能用于相邻两个独立使用场所的人员相互通行",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":60,"typeLabel":61,"stem":62,"options":63,"answer":69,"analysis":27},962588,1,"单选题","下列属于建筑物安全疏散设施的是（ ）。",[64,66,68,71],{"key":20,"text":65,"correct":26},"机械排烟系统",{"key":24,"text":67,"correct":26},"火灾自动报警系统",{"key":69,"text":70,"correct":22},"C","避难层",{"key":72,"text":73,"correct":26},"D","自动喷水灭火系统",{"id":75,"libraryId":5,"type":60,"typeLabel":61,"stem":76,"options":77,"answer":72,"analysis":27},962589,"下列不属于安全疏散设施的是（ ）。",[78,80,82,84],{"key":20,"text":79,"correct":26},"疏散指示标志",{"key":24,"text":81,"correct":26},"疏散走道",{"key":69,"text":83,"correct":26},"防火门",{"key":72,"text":85,"correct":22},"安全出口",{"id":87,"libraryId":5,"type":60,"typeLabel":61,"stem":88,"options":89,"answer":20,"analysis":27},962590,"下列关于楼梯间的设置要求不符合规范规定的是（ ）。",[90,92,94,96],{"key":20,"text":91,"correct":22},"楼梯间及前室可设置垃圾道",{"key":24,"text":93,"correct":26},"公共建筑的楼梯间内不应敷设可燃气体管道",{"key":69,"text":95,"correct":26},"楼梯间内不应有影响疏散的凸出物或其他障碍物",{"key":72,"text":97,"correct":26},"楼梯间应能天然采光和自然通风，并宜靠外墙设置",{"id":99,"libraryId":5,"type":60,"typeLabel":61,"stem":100,"options":101,"answer":72,"analysis":27},962591,"下列关于疏散走道的说法符合规范规定的是（ ）。",[102,104,106,108],{"key":20,"text":103,"correct":26},"疏散走道允许堆放杂物",{"key":24,"text":105,"correct":26},"疏散走道可以不设疏散指示标志",{"key":69,"text":107,"correct":26},"疏散走道可以设置屏风，只要是不燃烧体就行",{"key":72,"text":109,"correct":22},"疏散走道内不应设置阶梯、门槛、门垛等影响疏散的凸出物",{"id":111,"libraryId":5,"type":60,"typeLabel":61,"stem":112,"options":113,"answer":24,"analysis":27},962592,"下列关于安全出口的设置要求不符合规范规定的是（ ）。",[114,116,118,120],{"key":20,"text":115,"correct":26},"民用建筑的安全出口应分散布置。每个防火分区，一个防火分区的每个楼层，其相邻2个安全出口最近边缘之间的水平距离不应小于5m",{"key":24,"text":117,"correct":22},"单层、多层公共建筑内的每个防火分区，一个防火分区的每个楼层，其安全出口和疏散门的数量应经计算确定，且不小于1个",{"key":69,"text":119,"correct":26},"高层建筑每个防火分区以及高层建筑地下室、半地下室每个防火分区的安全出口不少于两个",{"key":72,"text":121,"correct":26},"高层建筑的安全出口应分散布置，且两个安全出口之间的距高不少于5m",{"id":123,"libraryId":5,"type":60,"typeLabel":61,"stem":124,"options":125,"answer":24,"analysis":27},962593,"剧院的安全出口疏散门的数量应计算确定，且不少于（ ）。",[126,128,130,132],{"key":20,"text":127,"correct":26},"1个",{"key":24,"text":129,"correct":22},"2个",{"key":69,"text":131,"correct":26},"3个",{"key":72,"text":133,"correct":26},"4个",{"id":135,"libraryId":5,"type":60,"typeLabel":61,"stem":136,"options":137,"answer":24,"analysis":27},962594,"高层建筑地下室每个防火分区的安全出口不少于（ ）。",[138,139,140,141],{"key":20,"text":127,"correct":26},{"key":24,"text":129,"correct":22},{"key":69,"text":131,"correct":26},{"key":72,"text":133,"correct":26},{"id":143,"libraryId":5,"type":60,"typeLabel":61,"stem":144,"options":145,"answer":69,"analysis":27},962595,"下列关于避难层的设置不符合要求的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"从首层到第一个避难层之间及两个避难层之间的高度不应大于50m",{"key":24,"text":149,"correct":26},"避难层的净面积应能满足设计避难人数避难要求，宜按5人\u002Fm2计算",{"key":69,"text":151,"correct":22},"避难层不可与设备层结合布置",{"key":72,"text":153,"correct":26},"避难层应设置消防电梯出口",{"id":155,"libraryId":5,"type":60,"typeLabel":61,"stem":156,"options":157,"answer":72,"analysis":27},962596,"下列关于疏散楼梯间的设置不符合规范规定的是（ ）。",[158,159,161,163],{"key":20,"text":97,"correct":26},{"key":24,"text":160,"correct":26},"楼梯间应在标准层或防火分区的两端设置，便于双向疏散",{"key":69,"text":162,"correct":26},"楼梯间不应有影响疏散的凸出物或其他障碍物",{"key":72,"text":164,"correct":22},"建筑内的疏散楼梯间在各层的平面位罝应错位设置",{"id":166,"libraryId":5,"type":60,"typeLabel":61,"stem":167,"options":168,"answer":72,"analysis":27},962597,"歌舞娱乐放映游艺场所内，其疏散门的净宽度不应小于（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":26},"0.9m",{"key":24,"text":172,"correct":26},"1.1m",{"key":69,"text":174,"correct":26},"1.2m",{"key":72,"text":176,"correct":22},"1.4m",{"id":178,"libraryId":5,"type":60,"typeLabel":61,"stem":179,"options":180,"answer":24,"analysis":27},962598,"某幼儿园耐火等级为三级，该幼儿园位于袋行走道两侧的房间疏散门至最近安全出口的最大距离应为（ ）m。",[181,183,185,187],{"key":20,"text":182,"correct":26},"15",{"key":24,"text":184,"correct":22},"20",{"key":69,"text":186,"correct":26},"25",{"key":72,"text":188,"correct":26},"30",{"id":190,"libraryId":5,"type":60,"typeLabel":61,"stem":191,"options":192,"answer":24,"analysis":27},962599,"除托儿所、幼儿园外，建筑面积不大于（ ）m2且人数不超过（ ）人的单层建筑或多层建筑的首层，可设置一个安全出口。",[193,195,197,199],{"key":20,"text":194,"correct":26},"100；50",{"key":24,"text":196,"correct":22},"200；50",{"key":69,"text":198,"correct":26},"300；30",{"key":72,"text":200,"correct":26},"100；30",{"id":202,"libraryId":5,"type":203,"typeLabel":204,"stem":205,"options":206,"answer":218,"analysis":27},962600,2,"多选题","下列应设置防烟楼梯间的是（ ）。",[207,209,211,213,215],{"key":20,"text":208,"correct":22},"—类高层建筑",{"key":24,"text":210,"correct":22},"建筑高度大于32m的二类高层建筑",{"key":69,"text":212,"correct":22},"建筑高度大于32m且任一层人数超过10人的高层厂房",{"key":72,"text":214,"correct":26},"建筑高度大于21m且不超过33m的住宅建筑",{"key":216,"text":217,"correct":22},"E","建筑地下3层，室内地面与出入口高差为9.6m","ABCE",{"id":220,"libraryId":5,"type":203,"typeLabel":204,"stem":221,"options":222,"answer":233,"analysis":27},962601,"下列应设置封闭楼梯间的有（ ）。",[223,225,227,229,231],{"key":20,"text":224,"correct":22},"多层医疗建筑",{"key":24,"text":226,"correct":26},"建筑高度35m的二类高层建筑",{"key":69,"text":228,"correct":22},"高层建筑的裙房",{"key":72,"text":230,"correct":22},"建筑高度25m的住宅楼",{"key":216,"text":232,"correct":22},"建筑高度20m的办公楼","ACDE",{"id":235,"libraryId":5,"type":203,"typeLabel":204,"stem":236,"options":237,"answer":248,"analysis":27},962602,"某地下商业总建筑面积为10万㎡，采用无门窗洞口的防火墙和耐火极限不低于2.00h的楼板分隔为建筑面积不大于20000㎡的区域。相邻区域确需局部连通时，采用下沉广场进行连通。下列关于下沉式广场的设置符合规范规定的是（ ）。",[238,240,242,244,246],{"key":20,"text":239,"correct":22},"分隔后的不同区域通向下沉式广场等室外开敞空间的开口最近边缘之间的水平距离不应小于13m",{"key":24,"text":241,"correct":22},"室外开敞空间除用于人员疏散外不得用于其他商业或可能导致火灾蔓延的用途，其中用于疏散的净面积不应小于169m2",{"key":69,"text":243,"correct":26},"下沉式广场等室外开敞空间内应设置不少于2部直通地面的疏散楼梯",{"key":72,"text":245,"correct":22},"当连接下沉广场的防火分区需利用下沉广场进行疏散时，疏散楼梯的总净宽度不应小于任一防火分区通向室外开敞空间的设计疏散总净宽度",{"key":216,"text":247,"correct":26},"确需设置防风雨篷时，防风雨篷不应完全封闭，四周开口部位应均匀布置，开口的面积不应小于该空间地面面积的60%，开口高度不应小于1.0m","ABD",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":21,"analysis":27},962603,"安全疏敢是指火灾时人员由危险区域向安全区城撒离的过程。",[253,254],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":21,"analysis":27},962604,"建筑的室外地坪以及类似的空旷场所、封闭楼梯间和防烟楼梯间、建筑屋顶平台、高层建筑中的是避难层和避难间可视为安全区域。",[259,260],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":25,"analysis":27},962605,"高层建筑的裙房和建筑高度不超过32m的二类高层建筑可采用防烟楼梯间。",[265,266],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":21,"analysis":27},962606,"当建筑地下层数为3层及3层以上或地下室内地面与室外出入口地坪高差大于10m时，疏散楼梯也应设置为防烟楼梯间。",[271,272],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":21,"analysis":27},962607,"避难层应设置消火栓和消防软管卷盘、直接对外的可开启窗口或独立的机械防烟设施、消防专线电话和应急广播。",[277,278],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":280,"libraryId":5,"type":60,"typeLabel":61,"stem":281,"options":282,"answer":69,"analysis":27},962608,"某医院病房楼建筑高度27m，建筑内单面布房的疏散走道的最小净宽度不应小于（ ）m，双面布房的疏散走道的最小净宽度不应小于（ ）m。",[283,285,287,289],{"key":20,"text":284,"correct":26},"1.20；1.30",{"key":24,"text":286,"correct":26},"1.30；1.40",{"key":69,"text":288,"correct":22},"1.40；1.50",{"key":72,"text":290,"correct":26},"1.50；1.40",{"id":292,"libraryId":5,"type":203,"typeLabel":204,"stem":293,"options":294,"answer":248,"analysis":27},962609,"下列建筑可设置一个安全出口的有（ ）。",[295,297,299,301,303],{"key":20,"text":296,"correct":22},"一级耐火等级办公建筑最多层数3层，每层最大建筑面积200m2且第2层和第3层的人数之和不越过50人",{"key":24,"text":298,"correct":22},"三级耐火等级办公建筑最多层数3层，每层最大建筑面积200m2且第2层和第3层的人数之和不越过25人",{"key":69,"text":300,"correct":26},"三级耐火等级医疗建筑最多层数3层，每层最大建筑面积100m2且第2层和第3层的人数之和不越过25人",{"key":72,"text":302,"correct":22},"四级耐火等级教学建筑最多层数2层，每层最大建筑面积200m2且第2层人数不超过15人",{"key":216,"text":304,"correct":26},"四级耐火等级歌舞娱乐场所最多层数2层，每层最大建筑面积100m2且第2层人数不超过20人",{"id":306,"libraryId":5,"type":60,"typeLabel":61,"stem":307,"options":308,"answer":24,"analysis":27},962610,"某办公楼建筑高度32m，地上8层，每层建筑面积为3000m2，耐火等级为一级。该建筑房间内任一点到房间直通疏散走道的疏散门的直线距离不应大于（ ）m。",[309,310,311,313],{"key":20,"text":182,"correct":26},{"key":24,"text":184,"correct":22},{"key":69,"text":312,"correct":26},"22",{"key":72,"text":314,"correct":26},"10",{"id":316,"libraryId":5,"type":60,"typeLabel":61,"stem":317,"options":318,"answer":72,"analysis":27},962611,"某教学建筑地上6层，耐火等级二级，建筑高度24m，教学楼内位于两个安全出口之间的房间门至最近的安全出口最大距离为（ ）m。",[319,320,321,322],{"key":20,"text":184,"correct":26},{"key":24,"text":186,"correct":26},{"key":69,"text":188,"correct":26},{"key":72,"text":323,"correct":22},"35",{"id":325,"libraryId":5,"type":60,"typeLabel":61,"stem":326,"options":327,"answer":24,"analysis":27},962612,"某四星级酒店建筑高度为52m，建筑内全部设置自动喷水灭火系统。酒店每层设置两部疏散楼梯，布置在走廊的两端，该建筑内位于两个安全出口之间的房间门至最近安全出口的最大直线距离为（ ）m。",[328,329,331,333],{"key":20,"text":188,"correct":26},{"key":24,"text":330,"correct":22},"37.5",{"key":69,"text":332,"correct":26},"40",{"key":72,"text":334,"correct":26},"50",{"id":336,"libraryId":5,"type":60,"typeLabel":61,"stem":337,"options":338,"answer":24,"analysis":27},962613,"某办公楼地上6层，建筑高度20m，采用外墙内保温系统时，选用了B1级的保温材料，其防护层的厚度不应小于（ ）mm。",[339,341,342,343],{"key":20,"text":340,"correct":26},"5",{"key":24,"text":314,"correct":22},{"key":69,"text":182,"correct":26},{"key":72,"text":184,"correct":26},{"id":345,"libraryId":5,"type":60,"typeLabel":61,"stem":346,"options":347,"answer":20,"analysis":27},962614,"某商业建筑内上下层连通的中庭，其连通部位的顶棚、墙面应采用（ ）级装修材料，其他部位应采用不低于（ ）级的装修材料。",[348,350,352,354],{"key":20,"text":349,"correct":22},"A、B1",{"key":24,"text":351,"correct":26},"B2",{"key":69,"text":353,"correct":26},"B1、B2",{"key":72,"text":355,"correct":26},"B2、B3",{"id":357,"libraryId":5,"type":60,"typeLabel":61,"stem":358,"options":359,"answer":20,"analysis":27},962615,"下列装修材料不属于按使用部位和功能分类的是（ ）。",[360,362,364,366],{"key":20,"text":361,"correct":22},"门窗装修材料",{"key":24,"text":363,"correct":26},"顶棚装修材料",{"key":69,"text":365,"correct":26},"墙面装修材料",{"key":72,"text":367,"correct":26},"地面装修材料",{"id":369,"libraryId":5,"type":60,"typeLabel":61,"stem":370,"options":371,"answer":24,"analysis":27},962616,"某医疗建筑高度40m，建筑外墙的装饰层可采用燃烧性能为（ ）的材料。",[372,374,376,378],{"key":20,"text":373,"correct":26},"A级",{"key":24,"text":375,"correct":22},"B1级",{"key":69,"text":377,"correct":26},"B2级",{"key":72,"text":379,"correct":26},"B3级",{"id":381,"libraryId":5,"type":60,"typeLabel":61,"stem":382,"options":383,"answer":69,"analysis":27},962617,"装修材料按其使用部位和功能可划分为（ ）类。",[384,386,388,390],{"key":20,"text":385,"correct":26},"四",{"key":24,"text":387,"correct":26},"六",{"key":69,"text":389,"correct":22},"七",{"key":72,"text":391,"correct":26},"八",{"id":393,"libraryId":5,"type":60,"typeLabel":61,"stem":394,"options":395,"answer":69,"analysis":27},962618,"下列关于建筑外墙外保温材料设计方案不符合规范规范规定的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":26},"建筑高度50m的住宅建筑，保温层与基层墙体、装饰层之间无空腔，选用燃烧性能为B1级的外保温材料",{"key":24,"text":399,"correct":26},"建筑高度40m的办公楼，保温层与基层墙体、装饰层之间无空腔，选用燃烧性能为B1级的外保温材料",{"key":69,"text":401,"correct":22},"建筑高度20m的展览建筑，保温层与基层墙体、装饰层之间无空腔，选用燃烧性能为B1级的外保温材料",{"key":72,"text":403,"correct":26},"建筑高度24m的办公建筑，保温层与基层墙体、装饰层之间有空腔，选用燃烧性能为B1级的外保温材料",{"id":405,"libraryId":5,"type":60,"typeLabel":61,"stem":406,"options":407,"answer":24,"analysis":27},962619,"下列属于有机一无机复合型保温材料的是（ ）。",[408,410,412,414],{"key":20,"text":409,"correct":26},"矿棉和岩棉",{"key":24,"text":411,"correct":22},"胶粉聚苯颗粒保温浆料",{"key":69,"text":413,"correct":26},"EPS板",{"key":72,"text":415,"correct":26},"XPS板",{"id":417,"libraryId":5,"type":203,"typeLabel":204,"stem":418,"options":419,"answer":428,"analysis":27},962620,"下列属于装修材料按其使用部位和功能分类的是（ ）。",[420,421,423,425,427],{"key":20,"text":367,"correct":22},{"key":24,"text":422,"correct":22},"隔断装修材料",{"key":69,"text":424,"correct":22},"固定家具",{"key":72,"text":426,"correct":22},"装饰织物",{"key":216,"text":361,"correct":26},"ABCD",{"id":430,"libraryId":5,"type":203,"typeLabel":204,"stem":431,"options":432,"answer":443,"analysis":27},962621,"从材料燃烧性能的角度看，用于建筑外墙的保温材料可以分为（ ）。",[433,435,437,439,441],{"key":20,"text":434,"correct":22},"不燃材料",{"key":24,"text":436,"correct":22},"难燃材料",{"key":69,"text":438,"correct":22},"可燃材料",{"key":72,"text":440,"correct":26},"易燃材料",{"key":216,"text":442,"correct":26},"极易燃材料","ABC",{"id":445,"libraryId":5,"type":203,"typeLabel":204,"stem":446,"options":447,"answer":458,"analysis":27},962622,"某综合建筑地上12层，建筑高度40m，建筑三层为电子游戏厅，该电子游戏厅的下列装修方案中，符合规范规定的有（ ）。",[448,450,452,454,456],{"key":20,"text":449,"correct":26},"游戏厅设置燃烧性能为B2级的座椅",{"key":24,"text":451,"correct":26},"采用燃烧性能为B1级的顶棚",{"key":69,"text":453,"correct":22},"墙面粘贴燃烧性能为B1级的布质壁纸",{"key":72,"text":455,"correct":22},"地面铺设燃烧性能为B1级的塑料地板",{"key":216,"text":457,"correct":22},"隔断采用燃烧性能为B1级的纤维石膏板","CDE",{"id":460,"libraryId":5,"type":203,"typeLabel":204,"stem":461,"options":462,"answer":473,"analysis":27},962623,"建筑高度为54m的住宅建筑，与基层墙体、装饰层之间无空腔外墙外保温系统，下列使用的保温材料燃烧性能符合要求的有（ ）。",[463,465,467,469,471],{"key":20,"text":464,"correct":22},"A级保温材料",{"key":24,"text":466,"correct":22},"B1级保温材料",{"key":69,"text":468,"correct":26},"B2级保温材料",{"key":72,"text":470,"correct":26},"B3级保温材料",{"key":216,"text":472,"correct":26},"B4级保温材料","AB",{"id":475,"libraryId":5,"type":203,"typeLabel":204,"stem":476,"options":477,"answer":473,"analysis":27},962624,"某高层建筑地下一层为夜总会，该夜总会的室内装修材料应采用A级装修材料的有（ ）。",[478,480,482,484,485],{"key":20,"text":479,"correct":22},"顶棚",{"key":24,"text":481,"correct":22},"地面",{"key":69,"text":483,"correct":26},"墙面",{"key":72,"text":424,"correct":26},{"key":216,"text":486,"correct":26},"隔断",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":25,"analysis":27},962625,"某商层办公建筑在进行内部装修时，采用壁柜将办公室分隔成多个区域。该壁柜可划分隔断装修材料",[491,492],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":25,"analysis":27},962626,"某民政部门建设了2座供老年人居住和活动的建筑，建筑高度均为12m，在进行内部装修时，建筑内疏散走道的顶棚装饰材料的燃烧性能等级应为B1级。",[497,498],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":25,"analysis":27},962627,"地下商店营业厅的地面装修材料允许采用B1级燃烧性能。",[503,504],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":25,"analysis":27},962628,"纸面石膏和无纺贴墙布属于B1级墙面装修材料。",[509,510],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":25,"analysis":27},962629,"某住宅封闭楼梯间的顶棚、墙面和地面均应采用B1级装修材料。",[515,516],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":25,"analysis":27},962630,"某歌舞厅设有火灾自动报警装置和自动灭火系统，分别位于地下、高层、多层建筑内时，其KTV包间顶棚的装修材料的燃烧性能分别不应低于A、A、B1级。",[521,522],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":25,"analysis":27},962631,"某多层医院，建筑高度23m，采用外墙内保温系统时，保温材料最低选用B1级。",[527,528],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[530,533,536,539,542,545],{"id":60,"name":531,"category":7,"favorite":532},"领导干部任职前廉政法规知识测试题",92,{"id":534,"name":535,"category":7,"favorite":60},595,"建筑结构与设备",{"id":537,"name":538,"category":7,"favorite":60},715,"招标采购专业知识与法律法规",{"id":540,"name":541,"category":7,"favorite":60},848,"市政方向-通用基础",{"id":543,"name":544,"category":7,"favorite":8},534,"BIM工程师",{"id":546,"name":544,"category":7,"favorite":8},535]