[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":524},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,23,50,2862,[13,28,34,40,56,68,80,91,103,115,123,133,142,152,160,172,178,184,190,196,208,216,226,234,242,252,260,268,276,284,292,304,322,330,345,360,368,379,393,402,417,426,438,450,460,468,480,492,504,516],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},962431,3,"判断题","当丁，戊类的地上厂房内设置自动灭火系统时，每个防火分区的最大允许建筑面积可增加1倍计算。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},962432,"防烟分区不应跨越防火分区。",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},962433,"挡烟垂壁是指用不燃材料制成，垂直安装在建筑顶棚、横梁或吊顶下，能在火灾时形成一定蓄烟空间的挡烟分隔设施。",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":42,"typeLabel":43,"stem":44,"options":45,"answer":54,"analysis":27},962434,1,"单选题","下列常见的防火分隔物不包括（ ）。",[46,48,50,53],{"key":20,"text":47,"correct":22},"防火墙",{"key":24,"text":49,"correct":22},"耐火楼板",{"key":51,"text":52,"correct":22},"C","防火卷帘",{"key":54,"text":55,"correct":26},"D","挡烟垂壁",{"id":57,"libraryId":5,"type":42,"typeLabel":43,"stem":58,"options":59,"answer":51,"analysis":27},962435,"在建筑内部采用防火墙、耐火楼板及其他防火分隔设施分隔而成，能在一定时间内防止火灾向同一建筑的其余部分蔓延的局部空间称为（ ）。",[60,62,64,66],{"key":20,"text":61,"correct":22},"防火间距",{"key":24,"text":63,"correct":22},"消防扑救面",{"key":51,"text":65,"correct":26},"防火分区",{"key":54,"text":67,"correct":22},"防烟分区",{"id":69,"libraryId":5,"type":42,"typeLabel":43,"stem":70,"options":71,"answer":51,"analysis":27},962436,"乙类厂房内划分防火分区设置的防火墙，其耐火极限不应低于（ ）。",[72,74,76,78],{"key":20,"text":73,"correct":22},"2.0h",{"key":24,"text":75,"correct":22},"3.0h",{"key":51,"text":77,"correct":26},"4.0h",{"key":54,"text":79,"correct":22},"5.0h",{"id":81,"libraryId":5,"type":42,"typeLabel":43,"stem":82,"options":83,"answer":51,"analysis":27},962437,"防火分区之间的墙上安装的防火窗其耐火极限为不低于（ ）。",[84,86,87,89],{"key":20,"text":85,"correct":22},"1.0h",{"key":24,"text":73,"correct":22},{"key":51,"text":88,"correct":26},"1.5h",{"key":54,"text":90,"correct":22},"0.5h",{"id":92,"libraryId":5,"type":42,"typeLabel":43,"stem":93,"options":94,"answer":20,"analysis":27},962438,"防火分区之间的防火墙上安装的门为（ ）。",[95,97,99,101],{"key":20,"text":96,"correct":26},"甲级防火门",{"key":24,"text":98,"correct":22},"乙级防火门",{"key":51,"text":100,"correct":22},"丙级防火门",{"key":54,"text":102,"correct":22},"普通门",{"id":104,"libraryId":5,"type":42,"typeLabel":43,"stem":105,"options":106,"answer":24,"analysis":27},962439,"净空高度为5m的工业建筑，防烟分区最大允许面积为（ ）m2",[107,109,111,113],{"key":20,"text":108,"correct":22},"500",{"key":24,"text":110,"correct":26},"1000",{"key":51,"text":112,"correct":22},"1500",{"key":54,"text":114,"correct":22},"2000",{"id":116,"libraryId":5,"type":42,"typeLabel":43,"stem":117,"options":118,"answer":20,"analysis":27},962440,"净空高度为3m的公共建筑，防烟分区最大允许面积为（ ）m2",[119,120,121,122],{"key":20,"text":108,"correct":26},{"key":24,"text":110,"correct":22},{"key":51,"text":112,"correct":22},{"key":54,"text":114,"correct":22},{"id":124,"libraryId":5,"type":42,"typeLabel":43,"stem":125,"options":126,"answer":54,"analysis":27},962441,"锅炉房、柴油发电机房内设置储油间时，应采用耐火极限不低于（ ）的防火隔墙与储油间分隔。",[127,128,129,131],{"key":20,"text":88,"correct":22},{"key":24,"text":73,"correct":22},{"key":51,"text":130,"correct":22},"2.5h",{"key":54,"text":132,"correct":26},"3h",{"id":134,"libraryId":5,"type":42,"typeLabel":43,"stem":135,"options":136,"answer":24,"analysis":27},962442,"建筑高度30m的住宅楼，防火分区的最大允许面积是（ ）m2。",[137,138,139,141],{"key":20,"text":110,"correct":22},{"key":24,"text":112,"correct":26},{"key":51,"text":140,"correct":22},"1200",{"key":54,"text":108,"correct":22},{"id":143,"libraryId":5,"type":42,"typeLabel":43,"stem":144,"options":145,"answer":54,"analysis":27},962443,"耐火等级为二级的单、多层民用建筑，内部设置自动灭火系统，防火分区的最大允许面积是（ ）m2",[146,147,148,150],{"key":20,"text":110,"correct":22},{"key":24,"text":112,"correct":22},{"key":51,"text":149,"correct":22},"2500",{"key":54,"text":151,"correct":26},"5000",{"id":153,"libraryId":5,"type":42,"typeLabel":43,"stem":154,"options":155,"answer":54,"analysis":27},962444,"下列不能用作防火分区分隔设施（ ）。",[156,157,158,159],{"key":20,"text":47,"correct":22},{"key":24,"text":49,"correct":22},{"key":51,"text":52,"correct":22},{"key":54,"text":55,"correct":26},{"id":161,"libraryId":5,"type":42,"typeLabel":43,"stem":162,"options":163,"answer":51,"analysis":27},962445,"耐火等级为三级的单，多层民用建筑，其允许建筑高度或层数为（ ）层。",[164,166,168,170],{"key":20,"text":165,"correct":22},"1",{"key":24,"text":167,"correct":22},"3",{"key":51,"text":169,"correct":26},"5",{"key":54,"text":171,"correct":22},"不限",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},962446,"防火分区是指在建筑内部采用防火墙、耐火楼板等分隔而成，防止火灾向同一建筑的其余部分蔓延的局部空间。",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},962447,"水平防火分区是指建筑某一楼层内采用具有一定耐火能力的防火分隔物（如防火墙、防火门、防火窗和防火卷帘等），按规定的建筑面积标准分隔的防火单元",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},962448,"防火墙上不应开设门、窗、洞口，确需开设时，应设置不可开启或火灾时能自动关闭的乙级防火门、窗。",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":25,"analysis":27},962449,"防火隔墙是建筑内防止火灾蔓延至相邻区域且耐火极限低于规定要求的不燃性墙体，是建筑功能区域分隔和设备用房分隔的特殊墙体。",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":42,"typeLabel":43,"stem":198,"options":199,"answer":51,"analysis":27},962450,"下列厂房的耐火等级、层数和每个防火分区的最大允许建筑面积符合规范要求的是（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":22},"甲类二级单层厂房每个防火分区的最大允许建筑面积为4000m2，多层为3000m2",{"key":24,"text":203,"correct":22},"乙类一级单层厂房每个防火分区的最大允许建筑面积为4000m2，多层为3000m2",{"key":51,"text":205,"correct":26},"丙类一级单层厂房每个防火分区的最大允许建筑面积不限，多层为6000m2",{"key":54,"text":207,"correct":22},"丁类三级单层厂房每个防火分区的最大允许建筑面积为3000m2，多层为2000m2",{"id":209,"libraryId":5,"type":42,"typeLabel":43,"stem":210,"options":211,"answer":54,"analysis":27},962451,"一、二级耐火等级的丙类地下或半地下厂房建筑，每个防火分区的最大允许建筑面积为（ ）m2。",[212,213,214,215],{"key":20,"text":112,"correct":22},{"key":24,"text":140,"correct":22},{"key":51,"text":110,"correct":22},{"key":54,"text":108,"correct":26},{"id":217,"libraryId":5,"type":42,"typeLabel":43,"stem":218,"options":219,"answer":51,"analysis":27},962452,"一、二级耐火等级乙类1、3、4项仓库最多允许层数为（ ）层。",[220,221,223,224],{"key":20,"text":165,"correct":22},{"key":24,"text":222,"correct":22},"2",{"key":51,"text":167,"correct":26},{"key":54,"text":225,"correct":22},"4",{"id":227,"libraryId":5,"type":42,"typeLabel":43,"stem":228,"options":229,"answer":51,"analysis":27},962453,"一、二级耐火等级乙类2、5、6项仓库最多允许层数为（ ）层。",[230,231,232,233],{"key":20,"text":165,"correct":22},{"key":24,"text":167,"correct":22},{"key":51,"text":169,"correct":26},{"key":54,"text":171,"correct":22},{"id":235,"libraryId":5,"type":42,"typeLabel":43,"stem":236,"options":237,"answer":24,"analysis":27},962454,"三级耐火等级丙类2项仓库最多允许层数为（ ）层。",[238,239,240,241],{"key":20,"text":165,"correct":22},{"key":24,"text":167,"correct":26},{"key":51,"text":169,"correct":22},{"key":54,"text":171,"correct":22},{"id":243,"libraryId":5,"type":42,"typeLabel":43,"stem":244,"options":245,"answer":24,"analysis":27},962455,"一、二级耐火等级地下或半地下仓库，存丙类物品里的2项，每个仓库防火分区的最大允许建筑面积为（ ）㎡。",[246,248,250,251],{"key":20,"text":247,"correct":22},"150",{"key":24,"text":249,"correct":26},"300",{"key":51,"text":108,"correct":22},{"key":54,"text":110,"correct":22},{"id":253,"libraryId":5,"type":42,"typeLabel":43,"stem":254,"options":255,"answer":51,"analysis":27},962456,"一、二级耐火等级地下或半地下仓库存放丁类物品，每个仓库防火分区的最大允许建筑面积为（ ）㎡",[256,257,258,259],{"key":20,"text":247,"correct":22},{"key":24,"text":249,"correct":22},{"key":51,"text":108,"correct":26},{"key":54,"text":110,"correct":22},{"id":261,"libraryId":5,"type":42,"typeLabel":43,"stem":262,"options":263,"answer":54,"analysis":27},962457,"一、二级耐火等级地下或半地下仓库存放戊类物品，每个仓库防火分区的最大允许建筑面积为（ ）㎡。",[264,265,266,267],{"key":20,"text":247,"correct":22},{"key":24,"text":249,"correct":22},{"key":51,"text":108,"correct":22},{"key":54,"text":110,"correct":26},{"id":269,"libraryId":5,"type":42,"typeLabel":43,"stem":270,"options":271,"answer":20,"analysis":27},962458,"公共建筑、工业建筑空间净高 （H）≤3.0m时，防烟分区的最大允许面积为（ ）㎡。",[272,273,274,275],{"key":20,"text":108,"correct":26},{"key":24,"text":110,"correct":22},{"key":51,"text":112,"correct":22},{"key":54,"text":114,"correct":22},{"id":277,"libraryId":5,"type":42,"typeLabel":43,"stem":278,"options":279,"answer":24,"analysis":27},962459,"公共建筑、工业建筑，当3.0＜空间净高 （H）≤6.0m时，防烟分区的最大允许面积为（ ）㎡。",[280,281,282,283],{"key":20,"text":108,"correct":22},{"key":24,"text":110,"correct":26},{"key":51,"text":112,"correct":22},{"key":54,"text":114,"correct":22},{"id":285,"libraryId":5,"type":42,"typeLabel":43,"stem":286,"options":287,"answer":54,"analysis":27},962460,"公共建筑、工业建筑空间净高 （H）＞6.0时，防烟分区的最大允许面积为（ ）㎡。",[288,289,290,291],{"key":20,"text":108,"correct":22},{"key":24,"text":110,"correct":22},{"key":51,"text":112,"correct":22},{"key":54,"text":114,"correct":26},{"id":293,"libraryId":5,"type":42,"typeLabel":43,"stem":294,"options":295,"answer":24,"analysis":27},962461,"公共建筑、工业建筑空间净高 （H）≤3.0m时，防烟分区的长边最大允许长度为（ ）m。",[296,298,300,302],{"key":20,"text":297,"correct":22},"9",{"key":24,"text":299,"correct":26},"24",{"key":51,"text":301,"correct":22},"36",{"key":54,"text":303,"correct":22},"60",{"id":305,"libraryId":5,"type":306,"typeLabel":307,"stem":308,"options":309,"answer":321,"analysis":27},962462,2,"多选题","下列关于不同耐火等级民用建筑防火分区的最大允许建筑面积说法正确的是（ ）",[310,312,314,316,318],{"key":20,"text":311,"correct":26},"一、二级耐火等级的高层民用建筑防火分区的最大允许建筑面积为1500㎡",{"key":24,"text":313,"correct":22},"一、二级耐火等级的单、多层民用建筑防火分区的最大允许建筑面积为3000㎡",{"key":51,"text":315,"correct":26},"三级耐火等级的单、多层民用建筑防火分区的最大允许建筑面积为1200㎡",{"key":54,"text":317,"correct":26},"四级耐火等级的单、多层民用建筑防火分区的最大允许建筑面积为600㎡",{"key":319,"text":320,"correct":22},"E","一级耐火等级的地下或半地下建筑（室）防火分区的最大允许建筑面积为300㎡","ACD",{"id":323,"libraryId":5,"type":42,"typeLabel":43,"stem":324,"options":325,"answer":51,"analysis":27},962463,"公共建筑、工业建筑，当3.0＜空间净高 （H）≤6.0m时，防烟分区的长边最大允许长度为（ ）m。",[326,327,328,329],{"key":20,"text":297,"correct":22},{"key":24,"text":299,"correct":22},{"key":51,"text":301,"correct":26},{"key":54,"text":303,"correct":22},{"id":331,"libraryId":5,"type":306,"typeLabel":307,"stem":332,"options":333,"answer":344,"analysis":27},962464,"下列关于仓库的层数和每个防火分区的最大允许建筑面积描述，说法不正确的是（ ）。",[334,336,338,340,342],{"key":20,"text":335,"correct":22},"一级耐火等级单层仓库，存乙类物品里的1、3、4项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为2000㎡、500㎡。",{"key":24,"text":337,"correct":26},"三级耐火等级单层仓库，存乙类物品里的1、3、4项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为250㎡、500㎡。",{"key":51,"text":339,"correct":22},"二级耐火等级单层仓库，存乙类物品里的2、5、6项项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为2800㎡、700㎡。",{"key":54,"text":341,"correct":22},"三级耐火等级单层仓库，存乙类物品里的2、5、6项项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为900㎡、300㎡。",{"key":319,"text":343,"correct":26},"一级耐火等级多层仓库，存乙类物品里的1、3、4项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为1500㎡、500㎡。","BE",{"id":346,"libraryId":5,"type":306,"typeLabel":307,"stem":347,"options":348,"answer":359,"analysis":27},962465,"下列说法正确的有（ ）。",[349,351,353,355,357],{"key":20,"text":350,"correct":26},"一级耐火等级单层仓库，存丙类物品里的1项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为4000㎡、1000㎡。",{"key":24,"text":352,"correct":26},"三级耐火等级单层仓库，存丙类物品里的1项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为1200㎡、400㎡。",{"key":51,"text":354,"correct":26},"二级耐火等级多层仓库，存丙类物品里的1项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为2800㎡、700㎡。",{"key":54,"text":356,"correct":22},"二级耐火等级多层仓库，存丙类物品里的2项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为6000㎡、1500㎡。",{"key":319,"text":358,"correct":26},"三级耐火等级单层仓库，存丙类物品里的2项，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积分别为2100㎡、700㎡。","ABCE",{"id":361,"libraryId":5,"type":42,"typeLabel":43,"stem":362,"options":363,"answer":20,"analysis":27},962466,"一、二级耐火等级地下或半地下仓库，存丙类物品里的1项，每个仓库防火分区的最大允许建筑面积为（ ）㎡。",[364,365,366,367],{"key":20,"text":247,"correct":26},{"key":24,"text":249,"correct":22},{"key":51,"text":108,"correct":22},{"key":54,"text":110,"correct":22},{"id":369,"libraryId":5,"type":42,"typeLabel":43,"stem":370,"options":371,"answer":24,"analysis":27},962467,"一级耐火等级单层建筑，存甲类物品里的3、4项，每个仓库防火分区的最大允许建筑面积为（ ）㎡。",[372,374,375,377],{"key":20,"text":373,"correct":22},"180",{"key":24,"text":303,"correct":26},{"key":51,"text":376,"correct":22},"750",{"key":54,"text":378,"correct":22},"250",{"id":380,"libraryId":5,"type":306,"typeLabel":307,"stem":381,"options":382,"answer":321,"analysis":27},962468,"厂房的耐火等级、层数和每个防火分区的最大允许建筑面积为（ ）㎡。",[383,385,387,389,391],{"key":20,"text":384,"correct":26},"甲类一级单层4000，多层3000",{"key":24,"text":386,"correct":22},"甲类二级单层3000，多层1500",{"key":51,"text":388,"correct":26},"乙类一级单层5000，多层4000，高层2000",{"key":54,"text":390,"correct":26},"乙类二级单层4000，多层3000，高层1500",{"key":319,"text":392,"correct":22},"丙类一级单层不限，多层4000，高层2000",{"id":394,"libraryId":5,"type":42,"typeLabel":43,"stem":395,"options":396,"answer":51,"analysis":27},962469,"三级耐火等级的戊类厂房建筑最多允许层数为（ ）层。",[397,398,399,400],{"key":20,"text":165,"correct":22},{"key":24,"text":222,"correct":22},{"key":51,"text":167,"correct":26},{"key":54,"text":401,"correct":22},"6",{"id":403,"libraryId":5,"type":306,"typeLabel":307,"stem":404,"options":405,"answer":416,"analysis":27},962470,"下列关于高层厂房的防火分区说法中，错误的是（ ）。",[406,408,410,412,414],{"key":20,"text":407,"correct":22},"一级耐火等级的乙类厂房设置高层厂房时，每个防火分区的最大允许建筑面积为2000㎡",{"key":24,"text":409,"correct":26},"二级耐火等级的乙类厂房设置高层厂房时，每个防火分区的最大允许建筑面积为1000㎡",{"key":51,"text":411,"correct":22},"一级耐火等级的丙类厂房设置高层厂房时，每个防火分区的最大允许建筑面积为3000㎡",{"key":54,"text":413,"correct":26},"二级耐火等级的丙类厂房设置高层厂房时，每个防火分区的最大允许建筑面积为1500㎡",{"key":319,"text":415,"correct":26},"一、二级耐火等级的丁类厂房设置高层厂房时，每个防火分区的最大允许建筑面积为6000㎡","BDE",{"id":418,"libraryId":5,"type":42,"typeLabel":43,"stem":419,"options":420,"answer":54,"analysis":27},962471,"当公共建筑、工业建筑空间净高超过6m且具有自然对流条件时，防烟分区的长边最大允许长度不应大于（ ）m。",[421,422,423,424],{"key":20,"text":299,"correct":22},{"key":24,"text":301,"correct":22},{"key":51,"text":303,"correct":22},{"key":54,"text":425,"correct":26},"75",{"id":427,"libraryId":5,"type":42,"typeLabel":43,"stem":428,"options":429,"answer":24,"analysis":27},962472,"公共建筑、工业建筑中的走道宽度不大于（ ）m时，其防烟分区的长边长度不应大于60m。",[430,432,434,436],{"key":20,"text":431,"correct":22},"9.0",{"key":24,"text":433,"correct":26},"2.5",{"key":51,"text":435,"correct":22},"3.0",{"key":54,"text":437,"correct":22},"6.0",{"id":439,"libraryId":5,"type":42,"typeLabel":43,"stem":440,"options":441,"answer":51,"analysis":27},962473,"某商业建筑，地上5层，地下2层，地上1-5层为商场，地下1-2层为设备用房和汽车库。下列关于柴油发电机房的设置说法符合规范规定的是（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"设置在建筑首层",{"key":24,"text":445,"correct":22},"设置在建筑的地下一层",{"key":51,"text":447,"correct":26},"设置在建筑的地下二层",{"key":54,"text":449,"correct":22},"采用耐火极限为2.00h的防火隔墙和1.00h的不燃性楼板与其他部位分隔，门釆用甲级防火门",{"id":451,"libraryId":5,"type":42,"typeLabel":43,"stem":452,"options":453,"answer":20,"analysis":27},962474,"两座耐火极限等级为一、二级的裙房和其他民用建筑之间的防火间距不应小于（ ）m。",[454,455,457,459],{"key":20,"text":401,"correct":26},{"key":24,"text":456,"correct":22},"7",{"key":51,"text":458,"correct":22},"8",{"key":54,"text":297,"correct":22},{"id":461,"libraryId":5,"type":42,"typeLabel":43,"stem":462,"options":463,"answer":20,"analysis":27},962475,"相邻两座高度相同的一级耐火等级建筑中相邻任一侧外墙为防火墙，屋顶的耐火极限不低于（ ）h时，其防火间距不限。",[464,465,466,467],{"key":20,"text":165,"correct":26},{"key":24,"text":222,"correct":22},{"key":51,"text":167,"correct":22},{"key":54,"text":225,"correct":22},{"id":469,"libraryId":5,"type":42,"typeLabel":43,"stem":470,"options":471,"answer":24,"analysis":27},962476,"相邻两座综合建筑中较低一座建筑的耐火等级为二级，相邻较低一面外墙为防火墙且屋顶无天窗，屋顶的耐火极限不低于1.00h时，其防火间距不应小于（ ）m；对于高层建筑，不应小于（ ）m。",[472,474,476,478],{"key":20,"text":473,"correct":22},"3；3",{"key":24,"text":475,"correct":26},"3.5；4",{"key":51,"text":477,"correct":22},"3.5；5",{"key":54,"text":479,"correct":22},"4.5；5",{"id":481,"libraryId":5,"type":42,"typeLabel":43,"stem":482,"options":483,"answer":20,"analysis":27},962477,"相邻两座耐火等级均为一级的办公建筑中较低一座建筑的屋顶无天窗，相邻较高一面外墙高出较低一座建筑的屋面15m及以下范围内的开口部位设置（ ）防火门，窗。",[484,486,488,490],{"key":20,"text":485,"correct":26},"甲级",{"key":24,"text":487,"correct":22},"乙级",{"key":51,"text":489,"correct":22},"丙级",{"key":54,"text":491,"correct":22},"丁级",{"id":493,"libraryId":5,"type":42,"typeLabel":43,"stem":494,"options":495,"answer":24,"analysis":27},962478,"乙类厂房与明火或散发火花地点的防火间距不宜小于（ ）m",[496,498,500,502],{"key":20,"text":497,"correct":22},"20",{"key":24,"text":499,"correct":26},"30",{"key":51,"text":501,"correct":22},"40",{"key":54,"text":503,"correct":22},"50",{"id":505,"libraryId":5,"type":42,"typeLabel":43,"stem":506,"options":507,"answer":24,"analysis":27},962479,"多层戊类厂房与戊类仓库的防火间距可按规范的规定减少（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":22},"1m",{"key":24,"text":511,"correct":26},"2m",{"key":51,"text":513,"correct":22},"3m",{"key":54,"text":515,"correct":22},"4m",{"id":517,"libraryId":5,"type":42,"typeLabel":43,"stem":518,"options":519,"answer":54,"analysis":27},962480,"为戊类厂房服务而单独设置的生活用房应按民用建筑确定，与所属厂房的防火间距不应小于（ ）m。",[520,521,522,523],{"key":20,"text":167,"correct":22},{"key":24,"text":225,"correct":22},{"key":51,"text":169,"correct":22},{"key":54,"text":401,"correct":26},[525,528,531,534,537,540],{"id":42,"name":526,"category":7,"favorite":527},"领导干部任职前廉政法规知识测试题",92,{"id":529,"name":530,"category":7,"favorite":42},595,"建筑结构与设备",{"id":532,"name":533,"category":7,"favorite":42},715,"招标采购专业知识与法律法规",{"id":535,"name":536,"category":7,"favorite":42},848,"市政方向-通用基础",{"id":538,"name":539,"category":7,"favorite":8},534,"BIM工程师",{"id":541,"name":539,"category":7,"favorite":8},535]