[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-700-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":520},{"id":5,"name":6,"category":7,"favorite":8},700,"基础知识（通用）","建筑工程",0,2,50,2862,[13,28,34,40,56,62,68,80,92,98,110,118,130,142,148,154,162,179,194,206,220,226,232,244,250,256,267,279,291,303,315,327,333,339,351,361,376,391,404,416,428,434,445,457,469,481,487,493,508,514],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},961362,3,"判断题","耐火等级低于四级的既有建筑，其耐火等级可按四级确定。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},961363,"建筑构件是否失去耐火稳定性、完整性和隔热性来判断构件是否达到了耐火极限。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},961364,"建筑耐火能力取决于建筑构件的耐火极限。",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":42,"typeLabel":43,"stem":44,"options":45,"answer":24,"analysis":27},961365,1,"单选题","消防车道的净宽度和净空高度均不应小于（ ）m。",[46,48,50,53],{"key":20,"text":47,"correct":26},"3.8",{"key":24,"text":49,"correct":22},"4",{"key":51,"text":52,"correct":26},"C","4.5",{"key":54,"text":55,"correct":26},"D","5",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":21,"analysis":27},961366,"厂房内设置自动灭火系统时，每个防火分区的最大允许建筑面积可按规范规定增加1.0倍。",[60,61],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":63,"libraryId":5,"type":15,"typeLabel":16,"stem":64,"options":65,"answer":21,"analysis":27},961367,"当丁、戊类的地上厂房内设置自动灭火系统时，每个防火分区的最大允许建筑面积不限。",[66,67],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":69,"libraryId":5,"type":42,"typeLabel":43,"stem":70,"options":71,"answer":51,"analysis":27},961368,"公共建筑内疏散走道和疏散楼梯的净宽度不应小于（ ）m。",[72,74,76,78],{"key":20,"text":73,"correct":26},"0.9",{"key":24,"text":75,"correct":26},"1",{"key":51,"text":77,"correct":22},"1.1",{"key":54,"text":79,"correct":26},"1.2",{"id":81,"libraryId":5,"type":42,"typeLabel":43,"stem":82,"options":83,"answer":24,"analysis":27},961369,"不燃性构件是指用不燃材料做成的构件，以下构件中（ ）不属于不燃性构件。",[84,86,88,90],{"key":20,"text":85,"correct":26},"混凝土楼板",{"key":24,"text":87,"correct":22},"木龙骨两面钉石膏板隔墙",{"key":51,"text":89,"correct":26},"砖墙",{"key":54,"text":91,"correct":26},"混凝土柱",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":25,"analysis":27},961370,"普通房屋建筑一般要比标志性建筑设计使用年限长。",[96,97],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":99,"libraryId":5,"type":42,"typeLabel":43,"stem":100,"options":101,"answer":24,"analysis":27},961371,"（ ）是指在楼梯间入口处设置门，以防止火灾的烟气和热气进入的楼梯间。",[102,104,106,108],{"key":20,"text":103,"correct":26},"敞开楼梯间",{"key":24,"text":105,"correct":22},"封闭楼梯间",{"key":51,"text":107,"correct":26},"防烟楼梯间",{"key":54,"text":109,"correct":26},"室外疏散楼梯",{"id":111,"libraryId":5,"type":42,"typeLabel":43,"stem":112,"options":113,"answer":54,"analysis":27},961372,"（ ）是指在建筑的外墙上设置的全部敞开的楼梯。",[114,115,116,117],{"key":20,"text":103,"correct":26},{"key":24,"text":105,"correct":26},{"key":51,"text":107,"correct":26},{"key":54,"text":109,"correct":22},{"id":119,"libraryId":5,"type":42,"typeLabel":43,"stem":120,"options":121,"answer":54,"analysis":27},961373,"以下建筑中（ ）符合高层建筑的判定标准。",[122,124,126,128],{"key":20,"text":123,"correct":26},"建筑高度为27m的住宅建筑",{"key":24,"text":125,"correct":26},"建筑高度为24m的公共建筑",{"key":51,"text":127,"correct":26},"建筑高度为24m的工业建筑",{"key":54,"text":129,"correct":22},"建筑高度大于24m的非单层建筑",{"id":131,"libraryId":5,"type":42,"typeLabel":43,"stem":132,"options":133,"answer":24,"analysis":27},961374,"一级耐火等级建筑是指主要建筑构件全部为不燃烧体且满足相应耐火极限要求的建筑。以下建筑中（ ）的耐火等级可以低于一级。",[134,136,138,140],{"key":20,"text":135,"correct":26},"民用的地下或半地下建筑",{"key":24,"text":137,"correct":22},"建筑高度54m的住宅建筑",{"key":51,"text":139,"correct":26},"一类高层建筑",{"key":54,"text":141,"correct":26},"建筑高度54m的医疗建筑",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},961375,"安全疏散是指火灾时人员由危险区域向安全区域撤离的过程。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},961376,"楼板层是楼房建筑中水平方向的承重构件，按房间层高将整幢建筑沿水平方向分为若干部分。",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":42,"typeLabel":43,"stem":156,"options":157,"answer":51,"analysis":27},961377,"（ ）是指在楼梯间入口处设置防烟的前室、开敞式阳台或凹廊等设施，且通向前室和楼梯间的门均为防火门，以防止火灾的烟气和热气进入的楼梯间。",[158,159,160,161],{"key":20,"text":103,"correct":26},{"key":24,"text":105,"correct":26},{"key":51,"text":107,"correct":22},{"key":54,"text":109,"correct":26},{"id":163,"libraryId":5,"type":9,"typeLabel":164,"stem":165,"options":166,"answer":178,"analysis":27},961379,"多选题","依据标准耐火试验，构件发生以下（ ）情况认为丧失完整性。",[167,169,171,173,175],{"key":20,"text":168,"correct":22},"棉垫被点燃",{"key":24,"text":170,"correct":26},"任一位置的温升超过初始温度180℃",{"key":51,"text":172,"correct":26},"平均温升超过初始平均温度140℃",{"key":54,"text":174,"correct":22},"缝隙探棒可以穿过",{"key":176,"text":177,"correct":22},"E","背火面出现火焰且持续时间超过10s","ADE",{"id":180,"libraryId":5,"type":9,"typeLabel":164,"stem":181,"options":182,"answer":193,"analysis":27},961380,"耐火极限是指在标准耐火试验条件下，建筑构件、配件或结构从受到火的作用时起，至（ ）时止所用的时间，用小时（h）表示。",[183,185,187,189,191],{"key":20,"text":184,"correct":22},"失去承载力",{"key":24,"text":186,"correct":22},"失去完整性",{"key":51,"text":188,"correct":22},"失去隔热性",{"key":54,"text":190,"correct":26},"火灾扑灭",{"key":176,"text":192,"correct":26},"人员疏散完成","ABC",{"id":195,"libraryId":5,"type":42,"typeLabel":43,"stem":196,"options":197,"answer":51,"analysis":27},961381,"对于丁、戊类储存物品仓库的火灾危险性，当可燃包装质量大于物品本身质量（ ），应按丙类确定。",[198,200,202,204],{"key":20,"text":199,"correct":26},"1\u002F2",{"key":24,"text":201,"correct":26},"1\u002F3",{"key":51,"text":203,"correct":22},"1\u002F4",{"key":54,"text":205,"correct":26},"1\u002F5",{"id":207,"libraryId":5,"type":9,"typeLabel":164,"stem":208,"options":209,"answer":193,"analysis":27},961382,"以下材料（制品）中，（ ）属于A级材料。",[210,212,214,216,218],{"key":20,"text":211,"correct":22},"大理石",{"key":24,"text":213,"correct":22},"花岗岩",{"key":51,"text":215,"correct":22},"玻璃",{"key":54,"text":217,"correct":26},"矿棉板",{"key":176,"text":219,"correct":26},"墙布",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},961383,"建筑内部装修设计应尽可能采用不燃材料和难燃材料，避免采用燃烧时产生大量浓烟或有毒气体的材料，同时采取有效的防火措施。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},961384,"建筑材料是指建筑中所使用的各种材料的总称，其燃烧性能直接关系到建筑的防火安全。",[230,231],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":233,"libraryId":5,"type":42,"typeLabel":43,"stem":234,"options":235,"answer":20,"analysis":27},961385,"我国建筑材料及制品燃烧性能分为 A、B1、B2、B3四个等级，其中A级材料对应的是（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":22},"不燃材料",{"key":24,"text":239,"correct":26},"难燃材料",{"key":51,"text":241,"correct":26},"可燃材料",{"key":54,"text":243,"correct":26},"易燃材料",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":25,"analysis":27},961386,"所有的厂房防火分区之间只能采用防火墙分隔。",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},961387,"由于水平防火分区是按照建筑面积划分的，因此也称为面积防火分区。",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":42,"typeLabel":43,"stem":258,"options":259,"answer":51,"analysis":27},961388,"可燃性构件是指用可燃材料做成的构件，以下构件中（ ）不属于可燃性构件。",[260,262,264,265],{"key":20,"text":261,"correct":26},"木柱",{"key":24,"text":263,"correct":26},"木楼板",{"key":51,"text":89,"correct":22},{"key":54,"text":266,"correct":26},"竹楼梯",{"id":268,"libraryId":5,"type":42,"typeLabel":43,"stem":269,"options":270,"answer":24,"analysis":27},961389,"建筑高度为21米的医疗建筑属于（ ）。",[271,273,275,277],{"key":20,"text":272,"correct":26},"一类高层住宅建筑",{"key":24,"text":274,"correct":22},"多层建筑",{"key":51,"text":276,"correct":26},"一类高层公共建筑",{"key":54,"text":278,"correct":26},"二类高层公共建筑",{"id":280,"libraryId":5,"type":42,"typeLabel":43,"stem":281,"options":282,"answer":24,"analysis":27},961390,"火灾危险性较大的生产部分占本层或本防火分区建筑面积的比例小于（ ）且发生火灾事故时不足以蔓延至其他部位或火灾危险性较大的生产部分釆取了有效的防火措施。可按火灾危险性较小的部分确定。",[283,285,287,289],{"key":20,"text":284,"correct":26},"0.02",{"key":24,"text":286,"correct":22},"0.05",{"key":51,"text":288,"correct":26},"0.1",{"key":54,"text":290,"correct":26},"0.2",{"id":292,"libraryId":5,"type":42,"typeLabel":43,"stem":293,"options":294,"answer":20,"analysis":27},961391,"（ ）是指屋顶采用钢结构，其他主要承重构件采用钢筋混凝土结构的建筑。",[295,297,299,301],{"key":20,"text":296,"correct":22},"钢与钢筋混凝土混合结构（钢混结构）建筑",{"key":24,"text":298,"correct":26},"砖木结构建筑",{"key":51,"text":300,"correct":26},"钢筋混凝土结构建筑",{"key":54,"text":302,"correct":26},"钢结构建筑",{"id":304,"libraryId":5,"type":42,"typeLabel":43,"stem":305,"options":306,"answer":20,"analysis":27},961392,"建筑按结构的设计使用年限分类以下（ ）设计使用年限最短。",[307,309,311,313],{"key":20,"text":308,"correct":22},"临时性建筑",{"key":24,"text":310,"correct":26},"易于替换结构构件的建筑",{"key":51,"text":312,"correct":26},"普通房屋和构筑物",{"key":54,"text":314,"correct":26},"标志性建筑和特别重要的建筑",{"id":316,"libraryId":5,"type":42,"typeLabel":43,"stem":317,"options":318,"answer":24,"analysis":27},961393,"以下关于使用或产生物质火灾危险性特征的描述中，（ ）不属于乙类火灾危险性物质。",[319,321,323,325],{"key":20,"text":320,"correct":26},"闪点不小于28℃，但小于60℃的液体",{"key":24,"text":322,"correct":22},"闪点不小于60℃的液体",{"key":51,"text":324,"correct":26},"爆炸下限不小于10%的气体",{"key":54,"text":326,"correct":26},"能与空气形成爆炸性混合物的浮游状态的粉尘、纤维、闪点不小于60℃的液体雾滴",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":25,"analysis":27},961394,"避难层是建筑高度超过100m的公共建筑和工业建筑中发生火灾时供人员临时避难使用的楼层。",[331,332],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":25,"analysis":27},961395,"基础是位于建筑最下部的承重构件，承受着建筑的大部分荷载，并将这些荷载传递给地基。",[337,338],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":340,"libraryId":5,"type":42,"typeLabel":43,"stem":341,"options":342,"answer":51,"analysis":27},961396,"（ ）是指建筑某一楼层内采用具有一定耐火能力的防火分隔物，按规定的建筑面积标准分隔的防火单元。",[343,345,347,349],{"key":20,"text":344,"correct":26},"防火分区",{"key":24,"text":346,"correct":26},"防火分隔",{"key":51,"text":348,"correct":22},"水平防火分区",{"key":54,"text":350,"correct":26},"竖向防火分区",{"id":352,"libraryId":5,"type":42,"typeLabel":43,"stem":353,"options":354,"answer":24,"analysis":27},961397,"公共建筑内每个房间相邻2个疏散门最近边缘之间的水平距离不应小于（ ）m。",[355,356,357,359],{"key":20,"text":49,"correct":26},{"key":24,"text":55,"correct":22},{"key":51,"text":358,"correct":26},"6",{"key":54,"text":360,"correct":26},"8",{"id":362,"libraryId":5,"type":9,"typeLabel":164,"stem":363,"options":364,"answer":375,"analysis":27},961398,"建筑总平面布局应综合考虑建筑的（ ）因素后再确定。",[365,367,369,371,373],{"key":20,"text":366,"correct":22},"使用性质",{"key":24,"text":368,"correct":22},"火灾危险性",{"key":51,"text":370,"correct":26},"人员素质",{"key":54,"text":372,"correct":22},"所处地理环境",{"key":176,"text":374,"correct":22},"生产经营规模","ABDE",{"id":377,"libraryId":5,"type":9,"typeLabel":164,"stem":378,"options":379,"answer":390,"analysis":27},961399,"避难层下列设置要求中，正确的是（ ）。",[380,382,384,386,388],{"key":20,"text":381,"correct":26},"两个避难层之间的高度不应大于60m",{"key":24,"text":383,"correct":22},"避难层应设置消火栓和消防软管卷盘等设施",{"key":51,"text":385,"correct":22},"避难层应设置消防电梯出口",{"key":54,"text":387,"correct":22},"疏散楼梯应在避难层分隔、同层错位或上下层断开",{"key":176,"text":389,"correct":22},"避难层的净面积应能满足设计避难人数避难的要求，宜按5人\u002Fm2计算","BCDE",{"id":392,"libraryId":5,"type":9,"typeLabel":164,"stem":393,"options":394,"answer":403,"analysis":27},961400,"以下属于影响建筑耐火等级选定的因素主要有，建筑物的（ ）。",[395,397,398,399,401],{"key":20,"text":396,"correct":22},"重要性",{"key":24,"text":366,"correct":22},{"key":51,"text":368,"correct":22},{"key":54,"text":400,"correct":22},"高度和面积",{"key":176,"text":402,"correct":26},"火灾的种类","ABCD",{"id":405,"libraryId":5,"type":42,"typeLabel":43,"stem":406,"options":407,"answer":54,"analysis":27},961401,"下列场所中，应选用铝芯线缆的是（ ）",[408,410,412,414],{"key":20,"text":409,"correct":26},"市政照明",{"key":24,"text":411,"correct":26},"学生公寓",{"key":51,"text":413,"correct":26},"桑拿浴室",{"key":54,"text":415,"correct":22},"氨压缩机房",{"id":417,"libraryId":5,"type":42,"typeLabel":43,"stem":418,"options":419,"answer":20,"analysis":27},961402,"电气技术文字符号分为基本文字符号和辅助文字符号两类。基本文字符号主要表示电气设备、装置和元器件的种类名称，分为单字母符号和双字母符号。双字母符号中，表示按钮开关的是（ ）",[420,422,424,426],{"key":20,"text":421,"correct":22},"SB",{"key":24,"text":423,"correct":26},"SP",{"key":51,"text":425,"correct":26},"SQ",{"key":54,"text":427,"correct":26},"ST",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":25,"analysis":27},961403,"端线与端线之间的电压叫做端电压，也叫做相电压。",[432,433],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":435,"libraryId":5,"type":42,"typeLabel":43,"stem":436,"options":437,"answer":51,"analysis":27},961404,"穿管敷设的铜芯绝缘软线，导线最小允许截面积是（ ）mm2。",[438,440,442,443],{"key":20,"text":439,"correct":26},"0.5",{"key":24,"text":441,"correct":26},"0.75",{"key":51,"text":75,"correct":22},{"key":54,"text":444,"correct":26},"1.5",{"id":446,"libraryId":5,"type":42,"typeLabel":43,"stem":447,"options":448,"answer":51,"analysis":27},961405,"对于中小容量电动机，用（ ）进行短路保护既简单有可靠。",[449,451,453,455],{"key":20,"text":450,"correct":26},"断路器",{"key":24,"text":452,"correct":26},"热继电器",{"key":51,"text":454,"correct":22},"熔断器",{"key":54,"text":456,"correct":26},"欠电流继电器",{"id":458,"libraryId":5,"type":42,"typeLabel":43,"stem":459,"options":460,"answer":24,"analysis":27},961406,"能够储存磁场能量的电路元件是（ ）",[461,463,465,467],{"key":20,"text":462,"correct":26},"电阻",{"key":24,"text":464,"correct":22},"电感",{"key":51,"text":466,"correct":26},"电容",{"key":54,"text":468,"correct":26},"电源",{"id":470,"libraryId":5,"type":42,"typeLabel":43,"stem":471,"options":472,"answer":54,"analysis":27},961407,"以下电线电缆选择错误的是（ ）",[473,475,477,479],{"key":20,"text":474,"correct":26},"生活用移动式用电设备选用1.0mm2的铜芯软线。",{"key":24,"text":476,"correct":26},"生产用移动式用电设备选用1.0mm2的铜芯软线。",{"key":51,"text":478,"correct":26},"穿管敷设的绝缘导线选用1.0mm2的铜芯软线。",{"key":54,"text":480,"correct":22},"沿墙明敷的塑料护套线选用1.0mm2的铜芯软线。",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":25,"analysis":27},961408,"同种用途的电缆，宜分开敷设，并对其进行防火分隔。",[485,486],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":21,"analysis":27},961409,"电路的基本组成部分是电源、负载和连接电源与负载的中间环节",[491,492],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":494,"libraryId":5,"type":9,"typeLabel":164,"stem":495,"options":496,"answer":507,"analysis":27},961410,"变电站依据其在电力系统中的地位和作用可划分为（ ）",[497,499,501,503,505],{"key":20,"text":498,"correct":22},"系统枢纽变电站",{"key":24,"text":500,"correct":22},"地区一次变电站",{"key":51,"text":502,"correct":22},"地区二次变电站",{"key":54,"text":504,"correct":26},"地区三次变电站",{"key":176,"text":506,"correct":22},"终端变电站","ABCE",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":25,"analysis":27},961412,"IT系统是指电源中性点接地或通过阻抗（电阻器、电抗器）接地，电气装置外露可导电部分单独直接接地的系统。",[512,513],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":25,"analysis":27},961413,"常用电气仪表，按照仪表的安装方式，可分为垂直安装仪表和水平使用仪表。",[518,519],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[521,524,527,530,533,536],{"id":42,"name":522,"category":7,"favorite":523},"领导干部任职前廉政法规知识测试题",92,{"id":525,"name":526,"category":7,"favorite":42},595,"建筑结构与设备",{"id":528,"name":529,"category":7,"favorite":42},715,"招标采购专业知识与法律法规",{"id":531,"name":532,"category":7,"favorite":42},848,"市政方向-通用基础",{"id":534,"name":535,"category":7,"favorite":8},534,"BIM工程师",{"id":537,"name":535,"category":7,"favorite":8},535]