[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":586},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,9,50,1301,[13,34,46,58,70,82,94,106,118,126,138,146,156,168,176,188,200,212,224,236,248,260,272,284,296,306,318,329,341,349,360,371,383,395,407,419,431,443,453,464,473,484,492,504,516,528,540,550,562,574],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},960170,1,"单选题","在施工现场的防火巡查中，发现（ ），应当上报有关领导，制定限期改正措施。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","在建设工程内设置宿舍",true,{"key":24,"text":25,"correct":26},"B","施工现场内有吸烟现象",false,{"key":28,"text":29,"correct":26},"C","在建设工程内使用液化石油气",{"key":31,"text":32,"correct":26},"D","施工作业用火时没有领取用火证","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},960171,"在消防控制室的防火巡查中，发现（ ），应当上报有关领导，制定限期改正措施。",[38,40,42,44],{"key":20,"text":39,"correct":26},"值班人员脱岗",{"key":24,"text":41,"correct":22},"电源线破损",{"key":28,"text":43,"correct":26},"擅自关闭火灾自动报警、自动灭火系统",{"key":31,"text":45,"correct":26},"没有认真填写值班记录及系统运行登记表和控制器日检登记表",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},960172,"在消防控制室的防火巡查中，发现（ ），应当告知危害，协助当场改正。",[50,52,54,56],{"key":20,"text":51,"correct":26},"消防控制室没有应急照明系统",{"key":24,"text":53,"correct":26},"插座、插销不符合消防规范",{"key":28,"text":55,"correct":26},"灯具、电源开关不符合安全要求",{"key":31,"text":57,"correct":22},"没有2人以上专人值班",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},960173,"在外租商店的防火巡查中，发现（ ），应当上报有关领导，制定限期改正措施。",[62,64,66,68],{"key":20,"text":63,"correct":26},"灭火器被覆盖、遮挡",{"key":24,"text":65,"correct":26},"灭火器没有摆放在明显位置",{"key":28,"text":67,"correct":22},"灯具、插座、插销存在破损",{"key":31,"text":69,"correct":26},"消防通道有物品码放，被封堵",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},960175,"集中火灾报警控制器常采用（ ）结构，回路较多，内部电路结构大多设计成插板组合式，带载容量较大，操作使用方便。",[74,76,78,80],{"key":20,"text":75,"correct":26},"卧式",{"key":24,"text":77,"correct":26},"壁挂式",{"key":28,"text":79,"correct":22},"琴台式",{"key":31,"text":81,"correct":26},"立柜式",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},960177,"图1所示的各图标中是电源滤波器的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"④",{"key":24,"text":89,"correct":26},"⑥",{"key":28,"text":91,"correct":26},"⑨",{"key":31,"text":93,"correct":22},"⑩",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},960178,"（ ）火灾报警控制器不具有向其他控制器传递信息的功能。",[98,100,102,104],{"key":20,"text":99,"correct":22},"独立型",{"key":24,"text":101,"correct":26},"区域型",{"key":28,"text":103,"correct":26},"集中型",{"key":31,"text":105,"correct":26},"集中区域兼容型",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},960179,"火灾自动报警系统中用于为疏散人员和救援人员在现场提供火灾报警信息的设备是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"火灾探测器",{"key":24,"text":113,"correct":26},"手动报警按钮",{"key":28,"text":115,"correct":26},"声光警报器",{"key":31,"text":117,"correct":22},"火灾显示盘",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},960180,"图1所示的各图标中是总线滤波器的是（ ）。",[122,123,124,125],{"key":20,"text":87,"correct":26},{"key":24,"text":89,"correct":22},{"key":28,"text":91,"correct":26},{"key":31,"text":93,"correct":26},{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},960181,"多线制火灾应急广播系统由消防控制室的广播设备，配合火灾报警控制器、现场（ ）组成。",[130,132,134,136],{"key":20,"text":131,"correct":26},"消防广播分配盘",{"key":24,"text":133,"correct":22},"广播扬声器",{"key":28,"text":135,"correct":26},"广播功率放大器",{"key":31,"text":137,"correct":26},"模块",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},960182,"一般区域型或集中区域兼容型火灾报警控制器常采用（ ）结构，适合安装在墙壁上，占用空间较小。",[142,143,144,145],{"key":20,"text":75,"correct":26},{"key":24,"text":77,"correct":22},{"key":28,"text":79,"correct":26},{"key":31,"text":81,"correct":26},{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":20,"analysis":33},960184,"（ ）火灾报警控制器特点占地面积大，回路较多，带载容量较大，操作使用方便。",[150,151,153,154],{"key":20,"text":79,"correct":22},{"key":24,"text":152,"correct":26},"柜式",{"key":28,"text":77,"correct":26},{"key":31,"text":155,"correct":26},"独立式",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":24,"analysis":33},960187,"消防控制室应长期妥善保管相应的竣工消防系统设计图纸、系统（ ）、各分系统控制逻辑关系说明、建筑消防设施的验收文件等。",[160,162,164,166],{"key":20,"text":161,"correct":26},"流程图",{"key":24,"text":163,"correct":22},"调试记录",{"key":28,"text":165,"correct":26},"操作规程",{"key":31,"text":167,"correct":26},"功能表",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":28,"analysis":33},960188,"图1所示的各图标中是变压器的是（ ）。",[172,173,174,175],{"key":20,"text":87,"correct":26},{"key":24,"text":89,"correct":26},{"key":28,"text":91,"correct":22},{"key":31,"text":93,"correct":26},{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":31,"analysis":33},960189,"消防控制室应长期妥善保管相应的竣工消防系统设计图纸、（ ）、各分系统控制逻辑关系说明、建筑消防设施的验收文件等。",[180,182,184,186],{"key":20,"text":181,"correct":26},"接待制度",{"key":24,"text":183,"correct":26},"会议制度",{"key":28,"text":185,"correct":26},"卫生制度",{"key":31,"text":187,"correct":22},"安装施工图",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":28,"analysis":33},960193,"导致控制器主电故障的原因，下列叙述不正确的是（ ）。",[192,194,196,198],{"key":20,"text":193,"correct":26},"断电",{"key":24,"text":195,"correct":26},"线路故障",{"key":28,"text":197,"correct":22},"蓄电池欠压",{"key":31,"text":199,"correct":26},"保险管熔断",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":28,"analysis":33},960194,"当火灾报警控制器接收到故障报警时，（ ）故障总指示灯点亮。",[204,206,208,210],{"key":20,"text":205,"correct":26},"红色",{"key":24,"text":207,"correct":26},"绿色",{"key":28,"text":209,"correct":22},"黄色",{"key":31,"text":211,"correct":26},"灰色",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":24,"analysis":33},960195,"在备电自动保护后，为提示用户消防报警系统已关闭，控制器会提示（ ）h的故障声。",[216,218,220,222],{"key":20,"text":217,"correct":26},"0.5",{"key":24,"text":219,"correct":22},"1",{"key":28,"text":221,"correct":26},"1.5",{"key":31,"text":223,"correct":26},"2",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":31,"analysis":33},960197,"消防控制室内设有（ ）和消防设施控制设备。",[228,230,232,234],{"key":20,"text":229,"correct":26},"固定消防设施",{"key":24,"text":231,"correct":26},"防盗设备",{"key":28,"text":233,"correct":26},"检测设备",{"key":31,"text":235,"correct":22},"火灾自动报警设备",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":20,"analysis":33},960199,"消防控制室是建筑内消防设施系统的（ ）中心。",[240,242,244,246],{"key":20,"text":241,"correct":22},"控制",{"key":24,"text":243,"correct":26},"接收",{"key":28,"text":245,"correct":26},"显示",{"key":31,"text":247,"correct":26},"报警",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":28,"analysis":33},960200,"消防控制室应由火灾报警控制器或火灾报警控制器（联动型）、消防联动控制器、消防控制室图形显示装置、火灾应急广播、消防通讯电话等（ ）设备组合组成。",[252,254,256,258],{"key":20,"text":253,"correct":26},"全部",{"key":24,"text":255,"correct":26},"部分",{"key":28,"text":257,"correct":22},"全部或部分",{"key":31,"text":259,"correct":26},"任意",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":28,"analysis":33},960202,"当火灾报警控制器有火警、监管、故障报警、屏蔽等信息发生时，其中（ ）具有最高显示级别，优先显示，不受其他信息显示影响。",[264,266,268,270],{"key":20,"text":265,"correct":26},"监管报警",{"key":24,"text":267,"correct":26},"屏蔽",{"key":28,"text":269,"correct":22},"火灾报警信号",{"key":31,"text":271,"correct":26},"故障报警",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":28,"analysis":33},960204,"一旦出现火情，消防控制室将成为紧急信息汇集、显示、处理的中心，（ ）反馈火情的发展过程。",[276,278,280,282],{"key":20,"text":277,"correct":26},"最方便地",{"key":24,"text":279,"correct":26},"简要地",{"key":28,"text":281,"correct":22},"及时、准确地",{"key":31,"text":283,"correct":26},"有条件地",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":28,"analysis":33},960206,"下列不属于现场设备故障的现象是（ ）。",[288,290,292,294],{"key":20,"text":289,"correct":26},"探测器故障",{"key":24,"text":291,"correct":26},"模块故障",{"key":28,"text":293,"correct":22},"主电故障",{"key":31,"text":295,"correct":26},"手报故障",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":20,"analysis":33},960207,"总线制消防电话系统由设置在消防控制中心的总线制消防电话总机、（ ）和现场的消防电话接口、电话插孔及消防电话分机构成。",[300,302,303,304],{"key":20,"text":301,"correct":22},"火灾报警控制器",{"key":24,"text":131,"correct":26},{"key":28,"text":137,"correct":26},{"key":31,"text":305,"correct":26},"消防联动设备",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},960208,"消防电话总机是消防电话系统的组成部分，能够与消防电话分机进行（ ）语音通讯，具有综合控制功能、状态显示和故障监视功能。",[310,312,314,316],{"key":20,"text":311,"correct":26},"单工",{"key":24,"text":313,"correct":22},"双工",{"key":28,"text":315,"correct":26},"单频",{"key":31,"text":317,"correct":26},"双频",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":20,"analysis":33},960210,"消防控制室是利用（ ）扑救火灾的信息指挥中心。",[322,323,325,327],{"key":20,"text":229,"correct":22},{"key":24,"text":324,"correct":26},"移动通信设备",{"key":28,"text":326,"correct":26},"自动报警设备",{"key":31,"text":328,"correct":26},"消防控制设备",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":24,"analysis":33},960211,"在火灾报警控制器的工作原理中，通过（ ），完成控制器控制操作信息输入和输出信息显示。",[333,335,337,339],{"key":20,"text":334,"correct":26},"总线驱动单元",{"key":24,"text":336,"correct":22},"显示键盘操作单元",{"key":28,"text":338,"correct":26},"通信接口单元",{"key":31,"text":340,"correct":26},"输入输出接口单元",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":31,"analysis":33},960212,"集中型或集中区域兼容型火灾报警控制器常采用（ ）结构，回路较多，内部电路结构大多设计成插板组合式，带载容量较大，操作使用方便，占用面积小。",[345,346,347,348],{"key":20,"text":75,"correct":26},{"key":24,"text":77,"correct":26},{"key":28,"text":79,"correct":26},{"key":31,"text":81,"correct":22},{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},960214,"在平时，消防控制室全天候地（ ）各种消防设备的工作状态，保持系统的正常运行。",[353,355,357,358],{"key":20,"text":354,"correct":26},"报道",{"key":24,"text":356,"correct":22},"监控",{"key":28,"text":245,"correct":26},{"key":31,"text":359,"correct":26},"反馈",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":28,"analysis":33},960217,"集中火灾报警控制器或火灾报警控制器安装在墙上时，正面操作距离不应小于（ ）m。",[364,365,367,369],{"key":20,"text":219,"correct":26},{"key":24,"text":366,"correct":26},"1.1",{"key":28,"text":368,"correct":22},"1.2",{"key":31,"text":370,"correct":26},"1.3",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":31,"analysis":33},960218,"消防控制室的门应向（ ）开启，且入口处应设置明显的标志。",[375,377,379,381],{"key":20,"text":376,"correct":26},"室内",{"key":24,"text":378,"correct":26},"下",{"key":28,"text":380,"correct":26},"上",{"key":31,"text":382,"correct":22},"疏散方向",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":20,"analysis":33},960219,"消防控制室值班人员负责对各种消防控制设备的（ ），不得擅离职守，做好检查、操作等工作。",[387,389,391,393],{"key":20,"text":388,"correct":22},"监视和运用",{"key":24,"text":390,"correct":26},"守护和管理",{"key":28,"text":392,"correct":26},"维修和调试",{"key":31,"text":394,"correct":26},"信息反馈",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":31,"analysis":33},960220,"消防控制室图形显示装置主要由主机、（ ）、图形显示装置软件等软硬件设各组成。",[399,401,403,405],{"key":20,"text":400,"correct":26},"联动设备",{"key":24,"text":402,"correct":26},"电脑",{"key":28,"text":404,"correct":26},"硬盘",{"key":31,"text":406,"correct":22},"显示器",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":31,"analysis":33},960222,"火灾报警控制器或系统内各组成部分发生故障时所处的状态是（ ）。",[411,413,415,417],{"key":20,"text":412,"correct":26},"正常监视状态",{"key":24,"text":414,"correct":26},"自检状态",{"key":28,"text":416,"correct":26},"屏蔽状态",{"key":31,"text":418,"correct":22},"故障报警状态",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},960226,"主电断电情况下，火灾报警控制器自动投向备电供电，处于充满状态的备电至少连续供电（ ）h。",[423,425,427,429],{"key":20,"text":424,"correct":26},"7",{"key":24,"text":426,"correct":22},"8",{"key":28,"text":428,"correct":26},"9",{"key":31,"text":430,"correct":26},"10",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":24,"analysis":33},960227,"火灾报警控制器（联动型）电路构成与火灾报警控制器相似，主要增加（ ）。",[435,437,439,441],{"key":20,"text":436,"correct":26},"总线制控制盘及接口",{"key":24,"text":438,"correct":22},"多线制控制盘及接口",{"key":28,"text":440,"correct":26},"四线制控制盘及接口",{"key":31,"text":442,"correct":26},"智能电源盘及接口",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":28,"analysis":33},960228,"下列不属于现场设备故障的有（ ）。",[447,449,450,452],{"key":20,"text":448,"correct":26},"手动报警按钮故障",{"key":24,"text":291,"correct":26},{"key":28,"text":451,"correct":22},"备用电源故障",{"key":31,"text":289,"correct":26},{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":24,"analysis":33},960229,"当火灾报警控制器发出启动命令时，（ ）灯点亮，控制器进行复位操作后，此灯熄灭。",[457,458,460,462],{"key":20,"text":359,"correct":26},{"key":24,"text":459,"correct":22},"启动",{"key":28,"text":461,"correct":26},"火警",{"key":31,"text":463,"correct":26},"故障",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":20,"analysis":33},960230,"消防控制室内设有火灾自动报警设备和（ ）。",[468,470,471,472],{"key":20,"text":469,"correct":22},"消防设施控制设备",{"key":24,"text":231,"correct":26},{"key":28,"text":233,"correct":26},{"key":31,"text":229,"correct":26},{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":24,"analysis":33},960231,"消防控制室内，设备面盘的排列长度大于（ ）m时。其两端应设置宽度不小于1m的通道。",[477,478,480,482],{"key":20,"text":223,"correct":26},{"key":24,"text":479,"correct":22},"4",{"key":28,"text":481,"correct":26},"3",{"key":31,"text":483,"correct":26},"5",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":24,"analysis":33},960232,"消防控制室内，控制盘前操作距离单列布置时不应小于（ ）m。",[488,489,490,491],{"key":20,"text":217,"correct":26},{"key":24,"text":221,"correct":22},{"key":28,"text":223,"correct":26},{"key":31,"text":481,"correct":26},{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":31,"analysis":33},960233,"当火灾报警控制器备电报故障时，备电故障的原因下列说法不正确的是（ ）。",[496,498,500,502],{"key":20,"text":497,"correct":26},"蓄电池亏电",{"key":24,"text":499,"correct":26},"蓄电池损坏",{"key":28,"text":501,"correct":26},"备电断电",{"key":31,"text":503,"correct":22},"停电",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":20,"analysis":33},960234,"下面哪种情况不属于复位操作可以实现的功能（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":22},"火灾报警控制器的屏蔽状态受到复位操作的影响",{"key":24,"text":511,"correct":26},"复位所有总线制被控设备和手动消防启动盘、多线制消防联动控制盘上的状态指示灯",{"key":28,"text":513,"correct":26},"清除消音状态",{"key":31,"text":515,"correct":26},"清除当前的所有火警、故障和反馈等显示",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":24,"analysis":33},960235,"当火灾报警控制器主电故障时，下列叙述不正确的是（ ）。",[520,522,524,526],{"key":20,"text":521,"correct":26},"故障灯点亮",{"key":24,"text":523,"correct":22},"主电工作灯点亮",{"key":28,"text":525,"correct":26},"屏幕上显示主电故障",{"key":31,"text":527,"correct":26},"控制器发出故障声",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":31,"analysis":33},960238,"消防控制室宜设置在建筑物内（ ）的靠外墙部位。",[532,534,536,538],{"key":20,"text":533,"correct":26},"顶层",{"key":24,"text":535,"correct":26},"二层",{"key":28,"text":537,"correct":26},"避难层",{"key":31,"text":539,"correct":22},"首层",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":24,"analysis":33},960239,"火灾自动报警系统中用于人工触发火灾报警信号的设备是（ ）。",[544,546,547,548],{"key":20,"text":545,"correct":26},"感烟探测器",{"key":24,"text":113,"correct":22},{"key":28,"text":115,"correct":26},{"key":31,"text":549,"correct":26},"消火栓按钮",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":20,"analysis":33},960241,"系统设备发生异常的声音、光指示、气味等可能导致人身伤害或火灾危险情况时，下列不正确做法的是（ ）。",[554,556,558,560],{"key":20,"text":555,"correct":22},"控制器继续工作",{"key":24,"text":557,"correct":26},"向单位消防安全管理人报告",{"key":28,"text":559,"correct":26},"采取相应消防措施",{"key":31,"text":561,"correct":26},"记录详细关机情况及采取措施",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":24,"analysis":33},960242,"关于《消防控制室值班记录》填写说明要求叙述不正确的是（ ）。",[566,568,570,572],{"key":20,"text":567,"correct":26},"可根据消防控制室情况按照时间依次编写，序号内容以便于查询为主。",{"key":24,"text":569,"correct":22},"由消防安全管理人员填写所在时间段内火灾报警控制器的运行情况，如出现异常问题需填写相应原因和处理结果。",{"key":28,"text":571,"correct":26},"由值班人员填写所在时间段内控制室内其他消防系统运行情况，如出现异常问题需填写相应原因和处理结果。",{"key":31,"text":573,"correct":26},"由值班人员填写值班期间出现异常问题的具体时间。",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":20,"analysis":33},960243,"信息显示与查询功能当控制器处于某一高等级状态显示时，能通过（ ）操作查询其他低等级状态信息，各状态信息不交替显示。",[578,580,582,584],{"key":20,"text":579,"correct":22},"手动",{"key":24,"text":581,"correct":26},"自动",{"key":28,"text":583,"correct":26},"窗口",{"key":31,"text":585,"correct":26},"翻页",[587,590,593,596,599,602],{"id":15,"name":588,"category":7,"favorite":589},"领导干部任职前廉政法规知识测试题",92,{"id":591,"name":592,"category":7,"favorite":15},595,"建筑结构与设备",{"id":594,"name":595,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":597,"name":598,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":600,"name":601,"category":7,"favorite":8},534,"BIM工程师",{"id":603,"name":601,"category":7,"favorite":8},535]