[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":586},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,8,50,1301,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,189,199,211,223,235,244,254,266,278,290,302,314,325,337,349,361,373,385,397,405,417,426,436,448,460,472,480,492,504,516,524,533,545,555,566,578],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},960118,1,"单选题","常见的火源有七种类型，凸透镜与凹面镜等属于（ ）__。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","明火焰",false,{"key":24,"text":25,"correct":22},"B","化学反应放热",{"key":27,"text":28,"correct":22},"C","撞击与摩擦",{"key":30,"text":31,"correct":32},"D","光线照射与聚焦",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},960119,"设在疏散走道上的防火卷帘，应在卷帘的两侧设置启闭装置，并应具有（ ）、手动和机械控制的功能。",[38,40,42,44],{"key":20,"text":39,"correct":32},"自动",{"key":24,"text":41,"correct":22},"电动",{"key":27,"text":43,"correct":22},"遥控",{"key":30,"text":45,"correct":22},"温控",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},960120,"下列哪种情况不会产生电火花。（ ）_",[50,52,54,56],{"key":20,"text":51,"correct":22},"电气开关开启或关闭时",{"key":24,"text":53,"correct":22},"电路短路",{"key":27,"text":55,"correct":32},"使用防爆手电筒",{"key":30,"text":57,"correct":22},"电器设备漏电",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},960121,"锅炉房的防火巡查中，发现（ ），应当上报有关领导，制定限期改正措施。",[62,64,66,68],{"key":20,"text":63,"correct":22},"灭火器被挪作它用",{"key":24,"text":65,"correct":22},"人员离开后没有及时关闭电源",{"key":27,"text":67,"correct":22},"灭火器没摆放在明显位置",{"key":30,"text":69,"correct":32},"燃气阀门不能正常开启",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},960122,"当建筑物的沿街部分长度超过（ ）m时，应设置穿过建筑物的消防车道。",[74,76,78,80],{"key":20,"text":75,"correct":22},"100",{"key":24,"text":77,"correct":32},"150",{"key":27,"text":79,"correct":22},"200",{"key":30,"text":81,"correct":22},"220",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},960123,"丙级防火窗的耐火极限为不低于（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"1.5h",{"key":24,"text":89,"correct":22},"1.2h",{"key":27,"text":91,"correct":22},"0.9h",{"key":30,"text":93,"correct":32},"0.5h",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},960124,"在餐厅及厨房的防火巡查中，发现（ ），应当告知危害，协助当场改正。",[98,100,102,104],{"key":20,"text":99,"correct":22},"使用电器有超载现象",{"key":24,"text":101,"correct":32},"点锅后炉灶没有人看守",{"key":27,"text":103,"correct":22},"烟道内的油垢过多",{"key":30,"text":105,"correct":22},"没有配备石棉毯等简易灭火器材",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},960125,"民用建筑的每个防火分区，一个防火分区的每个楼层，其相邻2个安全出口最近边缘之间的水平距离不应小于（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"4m",{"key":24,"text":113,"correct":32},"5m",{"key":27,"text":115,"correct":22},"6m",{"key":30,"text":117,"correct":22},"7m",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},960126,"洗衣房的火源管理主要体现在（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":32},"电气线路和设备",{"key":24,"text":125,"correct":22},"烟头",{"key":27,"text":127,"correct":22},"煤气灶",{"key":30,"text":129,"correct":22},"燃气锅炉",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},960127,"（ ）是指建筑物内由墙体等围护构件构成的无封闭防烟功能，且与其他使用空间相通的楼梯间。",[134,136,138,140],{"key":20,"text":135,"correct":32},"敞开楼梯间",{"key":24,"text":137,"correct":22},"封闭楼梯间",{"key":27,"text":139,"correct":22},"防烟楼梯间",{"key":30,"text":141,"correct":22},"室外辅助疏散楼梯",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":30,"analysis":33},960128,"下列不属于防火卷帘巡查要点的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"防火卷帘下是否堆放杂物，影响降落",{"key":24,"text":149,"correct":22},"防火卷帘控制面板、门体等组件是否完好无损",{"key":27,"text":151,"correct":22},"防火卷帘是否处于正常升起状态",{"key":30,"text":153,"correct":32},"防火卷帘是否具备自动、手动和机械控制功能",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":27,"analysis":33},960129,"在地下停车场的防火巡查中，发现（ ），应当告知危害，协助当场改正。",[158,160,162,164],{"key":20,"text":159,"correct":22},"消防警示标志不醒目、被遮挡",{"key":24,"text":161,"correct":22},"疏散指示灯不能工作正常，外观有破损",{"key":27,"text":163,"correct":32},"有修车、加油、充电现象",{"key":30,"text":165,"correct":22},"应急照明不能工作正常，外观有破损",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},960131,"单层、多层民用建筑的消防车道为尽头式消防车道时应设回车道或回车场，供大型消防车使用时，回车场面积不应小于（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"12m×12m",{"key":24,"text":173,"correct":22},"15m×15m",{"key":27,"text":175,"correct":32},"18m×18m",{"key":30,"text":177,"correct":22},"21m×21m",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":30,"analysis":33},960132,"关于防火卷帘的巡查要点，下列说法不正确的是（ ）。",[182,183,185,187],{"key":20,"text":151,"correct":22},{"key":24,"text":184,"correct":22},"防火卷帘控制面板、门体是否完好无损",{"key":27,"text":186,"correct":22},"防火卷帘所对应的烟感、温感探头是否完好无损",{"key":30,"text":188,"correct":32},"防火卷帘下堆放杂物，只要不是可燃物就可以不管",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":20,"analysis":33},960133,"常见的火源有七种类型，白炽灯属于（ ）。",[193,195,196,198],{"key":20,"text":194,"correct":32},"高温物体",{"key":24,"text":21,"correct":22},{"key":27,"text":197,"correct":22},"电火花",{"key":30,"text":31,"correct":22},{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":20,"analysis":33},960134,"在外租商店的防火巡查中，发现（ ），应当告知危害，协助当场改正。",[203,205,207,209],{"key":20,"text":204,"correct":32},"经营过量易燃易爆危险品",{"key":24,"text":206,"correct":22},"电源线破损",{"key":27,"text":208,"correct":22},"灯具、电源开关不符合安全要求",{"key":30,"text":210,"correct":22},"电气线路有超负荷现象",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":27,"analysis":33},960135,"防火巡查人员应当及时纠正违章行为，妥善处置火灾危险，无法当场处置的，应当（ ）。",[215,217,219,221],{"key":20,"text":216,"correct":22},"立即强制执行",{"key":24,"text":218,"correct":22},"记录备案",{"key":27,"text":220,"correct":32},"立即报告",{"key":30,"text":222,"correct":22},"保持现状，以后再说",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":27,"analysis":33},960136,"安全疏散走道中，安全疏散指示标志灯的间距不应大于（ ）m。",[227,229,231,233],{"key":20,"text":228,"correct":22},"5",{"key":24,"text":230,"correct":22},"10",{"key":27,"text":232,"correct":32},"20",{"key":30,"text":234,"correct":22},"30",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":27,"analysis":33},960137,"公共建筑内的疏散走道和居住建筑内长度超过（ ）m的内走道，应设置应急照明。",[239,240,242,243],{"key":20,"text":230,"correct":22},{"key":24,"text":241,"correct":22},"15",{"key":27,"text":232,"correct":32},{"key":30,"text":234,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":27,"analysis":33},960138,"建筑面积大于（ ）㎡的地下、半地下建筑或地下室、半地下室中的公共活动房间等部位，应设置应急照明。",[248,249,250,252],{"key":20,"text":75,"correct":22},{"key":24,"text":79,"correct":22},{"key":27,"text":251,"correct":32},"300",{"key":30,"text":253,"correct":22},"400",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":30,"analysis":33},960139,"常开的防火门，在发生火灾时，应具有自行关闭和（ ）功能。",[258,260,262,264],{"key":20,"text":259,"correct":22},"自检",{"key":24,"text":261,"correct":22},"复位",{"key":27,"text":263,"correct":22},"现场警报",{"key":30,"text":265,"correct":32},"信号反馈",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":24,"analysis":33},960140,"电影院的安全出口和疏散门的数量应计算确定，且不少于（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":22},"1个",{"key":24,"text":273,"correct":32},"2个",{"key":27,"text":275,"correct":22},"3个",{"key":30,"text":277,"correct":22},"4个",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":20,"analysis":33},960141,"在施工现场的防火巡查中，发现（ ），应当告知危害，协助当场改正。",[282,284,286,288],{"key":20,"text":283,"correct":32},"施工作业用火时没有领取用火证",{"key":24,"text":285,"correct":22},"在临时消防车道上堆物、堆料或者挤占临时消防车道",{"key":27,"text":287,"correct":22},"建设工程内存放易燃易爆化学危险物品和易燃可燃材料",{"key":30,"text":289,"correct":22},"施工现场使用的安全网、围网和保温材料等是易燃或可燃的",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":27,"analysis":33},960142,"下列不属于安全疏散设施的是（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":22},"应急照明灯",{"key":24,"text":297,"correct":22},"疏散走道",{"key":27,"text":299,"correct":32},"防火门",{"key":30,"text":301,"correct":22},"安全出口",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":30,"analysis":33},960143,"关于疏散走道，说法正确的是（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"疏散走道允许堆放杂物",{"key":24,"text":309,"correct":22},"疏散走道可以不设疏散指示标志",{"key":27,"text":311,"correct":22},"疏散走道可以设置屏风，只要是不燃烧体就行",{"key":30,"text":313,"correct":32},"疏散走道内不应设置阶梯、门槛、门垛等影响疏散的凸出物",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":30,"analysis":33},960144,"在员工宿舍的防火巡查中，填写巡查记录表告知危害之后，应当协助当场改正的是（ ）。",[318,319,321,323],{"key":20,"text":206,"correct":22},{"key":24,"text":320,"correct":22},"插座、插销不符合消防规范",{"key":27,"text":322,"correct":22},"电源开关、灯具不符合安全要求",{"key":30,"text":324,"correct":32},"违章使用热水器、电热杯、电热毯等电热设备",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":20,"analysis":33},960145,"在散发可燃气体和可燃蒸汽的场所，应选用（ ）_照明灯具。",[329,331,333,335],{"key":20,"text":330,"correct":32},"防爆",{"key":24,"text":332,"correct":22},"防水",{"key":27,"text":334,"correct":22},"防尘",{"key":30,"text":336,"correct":22},"防风",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":20,"analysis":33},960146,"在办公室的防火巡查中，发现（ ），应当告知危害，协助当场改正。",[341,343,345,347],{"key":20,"text":342,"correct":32},"人员下班后未关闭电源",{"key":24,"text":344,"correct":22},"灯具存在破损",{"key":27,"text":346,"correct":22},"电源开关存在破损",{"key":30,"text":348,"correct":22},"电源线存在破损和老化",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":27,"analysis":33},960147,"关于疏散指示标志与应急照明的巡查要点，下列说法不正确的是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":22},"疏散指示标志外观是否完好无损，是否被悬挂物遮挡",{"key":24,"text":356,"correct":22},"疏散指示标志指示方向是否正确无误",{"key":27,"text":358,"correct":32},"疏散指示标志指示灯照明是否正常，充电电池电量可以不管",{"key":30,"text":360,"correct":22},"应急照明灯具是否处于正常工作状态",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":20,"analysis":33},960148,"关于在疏散走道和主要疏散路线设置灯光疏散指示标志说法不正确的是（ ）。",[365,367,369,371],{"key":20,"text":366,"correct":32},"总建筑面积超过10000㎡的展览建筑",{"key":24,"text":368,"correct":22},"总建筑面积超过5000㎡的地上商店",{"key":27,"text":370,"correct":22},"总建筑面积超过500㎡的地下、半地下商场、歌舞娱乐放映游艺场所",{"key":30,"text":372,"correct":22},"座位数超过1500个的电影院、剧院的疏散走道和主要疏散路线的地面上",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":30,"analysis":33},960149,"疏散指示标志和疏散应急照明灯设置描述错误的是（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":22},"疏散应急照明灯宜设在墙面上或顶棚上",{"key":24,"text":380,"correct":22},"安全出口标志宜设在出口顶部",{"key":27,"text":382,"correct":22},"疏散走道的指示标志宜设在疏散走道及其转角处距地面1m以下的墙面上",{"key":30,"text":384,"correct":32},"走道疏散指示标志灯间距不应大于15m",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},960150,"在装卸搬运爆炸性物品、氧化剂及有机过氧化物等对撞击和摩擦敏感度较高的物品时，应（ ）__，以防引起火灾和爆炸。",[389,391,393,395],{"key":20,"text":390,"correct":32},"轻拿轻放",{"key":24,"text":392,"correct":22},"撞击",{"key":27,"text":394,"correct":22},"拖拉",{"key":30,"text":396,"correct":22},"翻滚",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":33},960151,"单层、多层民用建筑的消防车道为尽头式消防车道时应设回车道或回车场，一般情况下回车场的面积不应小于（ ）。",[401,402,403,404],{"key":20,"text":171,"correct":32},{"key":24,"text":173,"correct":22},{"key":27,"text":175,"correct":22},{"key":30,"text":177,"correct":22},{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":30,"analysis":33},960152,"对于疏散楼梯和楼梯间、疏散走道、安全出口的每日巡查，下列说法不正确的是（ ）。",[409,411,413,415],{"key":20,"text":410,"correct":22},"是否有可燃物、易燃物堆放堵塞",{"key":24,"text":412,"correct":22},"是否有障碍物堆放，堵塞通道，影响疏散",{"key":27,"text":414,"correct":22},"安全出口是否被锁闭",{"key":30,"text":416,"correct":32},"火灾报警系统是否正常",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":24,"analysis":33},960153,"常见的火源有七种类型，黄磷在空气中自燃属于（ ）。",[421,423,424,425],{"key":20,"text":422,"correct":22},"绝热压缩",{"key":24,"text":25,"correct":32},{"key":27,"text":28,"correct":22},{"key":30,"text":31,"correct":22},{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":24,"analysis":33},960154,"乙级防火窗的耐火极限为不低于（ ）。",[430,431,433,434],{"key":20,"text":87,"correct":22},{"key":24,"text":432,"correct":32},"1.0h",{"key":27,"text":91,"correct":22},{"key":30,"text":435,"correct":22},"0.6h",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":27,"analysis":33},960155,"下列不属于防火分隔物的是（ ）。",[440,442,444,446],{"key":20,"text":441,"correct":22},"防火墙",{"key":24,"text":443,"correct":22},"防火阀",{"key":27,"text":445,"correct":32},"防火涂料",{"key":30,"text":447,"correct":22},"防火卷帘",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":27,"analysis":33},960156,"消防车道路面、扑救作业场地及其下面的管道和暗沟应能承受（ ）消防车的压力。",[452,454,456,458],{"key":20,"text":453,"correct":22},"普通",{"key":24,"text":455,"correct":22},"小型",{"key":27,"text":457,"correct":32},"大型",{"key":30,"text":459,"correct":22},"轻型",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":30,"analysis":33},960157,"防火巡查的部位一般是单位依据有关消防法规确定的重点部位，下列哪一项不是防火巡查的部位（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":22},"配电室",{"key":24,"text":467,"correct":22},"厨房",{"key":27,"text":469,"correct":22},"消防控制室",{"key":30,"text":471,"correct":32},"操场",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":24,"analysis":33},960158,"高层建筑每个防火分区以及高层建筑地下室、半地下室每个防火分区的安全出口不少于（ ）__。",[476,477,478,479],{"key":20,"text":271,"correct":22},{"key":24,"text":273,"correct":32},{"key":27,"text":275,"correct":22},{"key":30,"text":277,"correct":22},{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":30,"analysis":33},960159,"不是安全疏散设施的是（ ）__。",[484,486,488,490],{"key":20,"text":485,"correct":22},"应急照明和疏散指示标志",{"key":24,"text":487,"correct":22},"应急广播及辅助救生设施",{"key":27,"text":489,"correct":22},"超高层建筑需设置避难层和直升机停机坪",{"key":30,"text":491,"correct":32},"建筑内的所有防火卷帘",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":20,"analysis":33},960160,"关于楼梯间的设置要求表述错误的是（ ）。",[496,498,500,502],{"key":20,"text":497,"correct":32},"楼梯间不能靠外墙设置",{"key":24,"text":499,"correct":22},"公共建筑的楼梯间内不应敷设可燃气体管道",{"key":27,"text":501,"correct":22},"居住建筑的楼梯间内不应敷设可燃气体管道和设置可燃气体计量表",{"key":30,"text":503,"correct":22},"单元式住宅每个单元的疏散楼梯均应通至屋顶",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":30,"analysis":33},960161,"以下预防光线照射与聚焦成为火源的安全对策错误的是（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":22},"易燃易爆物品应严禁露天堆放，避免日光暴晒",{"key":24,"text":511,"correct":22},"对某些易燃易爆容器采取洒水降温和加设防晒棚措施，以防容器受热膨胀破裂，导致火灾爆炸",{"key":27,"text":513,"correct":22},"对可燃物品仓库和堆场，应注意日光聚焦点火现象，采取遮挡通风和冷却降温等方法实施保护",{"key":30,"text":515,"correct":32},"储存易燃易爆化学危险物品仓库的玻璃应采用透明玻璃",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":30,"analysis":33},960162,"常见的火源有七种类型，电焊时的电弧属于（ ）。",[520,521,522,523],{"key":20,"text":21,"correct":22},{"key":24,"text":194,"correct":22},{"key":27,"text":28,"correct":22},{"key":30,"text":197,"correct":32},{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":27,"analysis":33},960163,"高度超过100m的高层建筑中，应急照明和疏散指示标志，可采用蓄电池做备用电源，且它的连续供电时间不应少于（ ）min。",[528,529,530,531],{"key":20,"text":230,"correct":22},{"key":24,"text":232,"correct":22},{"key":27,"text":234,"correct":32},{"key":30,"text":532,"correct":22},"40",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":20,"analysis":33},960164,"以下应安装甲级防火门的是（ ）。",[537,539,541,543],{"key":20,"text":538,"correct":32},"变压器室的门",{"key":24,"text":540,"correct":22},"消防电梯前室的门",{"key":27,"text":542,"correct":22},"建筑物管道井的门",{"key":30,"text":544,"correct":22},"封闭楼梯间的门",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":27,"analysis":33},960165,"活动窗扇的防火窗应具备（ ）关闭功能。",[549,551,552,554],{"key":20,"text":550,"correct":22},"手动",{"key":24,"text":39,"correct":22},{"key":27,"text":553,"correct":32},"手动和自动",{"key":30,"text":41,"correct":22},{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":30,"analysis":33},960167,"在办公室的防火巡查中，填写巡查记录表告知危害之后，应当上报有关领导，制定限期整改措施的是（ ）。",[559,561,563,565],{"key":20,"text":560,"correct":22},"插排（插座）超负荷使用",{"key":24,"text":562,"correct":22},"人员下班后没有关闭电源",{"key":27,"text":564,"correct":22},"存放易燃易爆和大量可燃物",{"key":30,"text":322,"correct":32},{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":30,"analysis":33},960168,"在员工宿舍的防火巡查中，发现（ ），应当告知危害，协助当场改正。",[570,572,574,576],{"key":20,"text":571,"correct":22},"通向室外的疏散楼梯、防火门不符合要求",{"key":24,"text":573,"correct":22},"疏散指示标志、应急照明灯具不灵敏不好用",{"key":27,"text":575,"correct":22},"禁止卧床吸烟标志、疏散图没有按照要求配置",{"key":30,"text":577,"correct":32},"在宿舍或楼道内焚烧书信、文件、垃圾等物品",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":27,"analysis":33},960169,"乙级防火门的耐火极限为不低于（ ）。",[582,583,584,585],{"key":20,"text":87,"correct":22},{"key":24,"text":89,"correct":22},{"key":27,"text":432,"correct":32},{"key":30,"text":435,"correct":22},[587,590,593,596,599,602],{"id":15,"name":588,"category":7,"favorite":589},"领导干部任职前廉政法规知识测试题",92,{"id":591,"name":592,"category":7,"favorite":15},595,"建筑结构与设备",{"id":594,"name":595,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":597,"name":598,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":600,"name":601,"category":7,"favorite":8},534,"BIM工程师",{"id":603,"name":601,"category":7,"favorite":8},535]