[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":549},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,5,50,1301,[13,34,46,58,70,82,94,106,118,130,140,152,161,169,181,193,205,217,227,239,251,259,267,279,287,295,303,311,320,328,336,344,352,364,376,388,400,412,424,435,447,459,468,480,492,501,509,521,529,537],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},959930,1,"单选题","操作消防软管卷盘灭火完毕后，操作步骤不包括（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","关闭消防给水管道、喷枪阀门",false,{"key":24,"text":25,"correct":22},"B","将消防软管冲洗干净，置于阴凉干燥处晾干后，按原软管安置方式置于卷盘上",{"key":27,"text":28,"correct":22},"C","将已破碎的控制按钮玻璃清理干净，换上同等规格的玻璃片",{"key":30,"text":31,"correct":32},"D","将软管接口与室内消防给水管道上的接头连接",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":30,"analysis":33},959931,"（ ）是指其给水管网内始终保持灭火设施所需工作压力和流量，确保发生火灾时无须经过消防车或消防水泵加压的供水系统。",[38,40,42,44],{"key":20,"text":39,"correct":22},"室外低压消火栓给水系统",{"key":24,"text":41,"correct":22},"室外临时高压消火栓给水系统",{"key":27,"text":43,"correct":22},"室外临时低压消火栓给水系统",{"key":30,"text":45,"correct":32},"室外高压消火栓给水系统",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},959932,"过滤式消防自救呼吸器在使用中，下列做法正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"在抛光车间临时代替口罩使用",{"key":24,"text":53,"correct":22},"重复使用不超过两次",{"key":27,"text":55,"correct":32},"长发者将头发全部卷进头罩内",{"key":30,"text":57,"correct":22},"佩戴眼镜者，摘下眼镜使用",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},959933,"点型感烟火灾探测器火警和故障报警模拟测试时，其注意事项不包括（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"人员登高操作时，需注意安全",{"key":24,"text":65,"correct":22},"火警测试时，应采取相应的措施，防止测试区域的消防设备误动作",{"key":27,"text":67,"correct":22},"测试结束后，应使系统恢复至正常监视状态",{"key":30,"text":69,"correct":32},"切勿触碰220V供电线路接线端子",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},959934,"启动火灾警报装置操作中，当火灾报警控制器接收到首个火灾探测器报警信号后，首先进行的操作是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":32},"最快方式确认是否发生火灾",{"key":24,"text":77,"correct":22},"确认火灾警报器声、光输出状态",{"key":27,"text":79,"correct":22},"操作火灾报警控制器直接启动火灾警报器",{"key":30,"text":81,"correct":22},"现场按下手动火灾报警按钮",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},959935,"在室外消火栓操作过程中，下列注意事项不正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"用消火栓扳手转动消火栓启闭杆，观察其灵活性，必要时加注润滑油",{"key":24,"text":89,"correct":22},"检查栓体外表面有无锈蚀、脱落，如有应及时补漆",{"key":27,"text":91,"correct":32},"不需要清理消火栓周围、地下消火栓井内障碍物和积存的杂物",{"key":30,"text":93,"correct":22},"室外消火栓应有明显标志",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},959936,"下列不属于火灾报警装置保养项目的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"运行环境检查",{"key":24,"text":101,"correct":22},"设备外观检查",{"key":27,"text":103,"correct":32},"火灾报警功能检查",{"key":30,"text":105,"correct":22},"启动功能检查",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":30,"analysis":33},959937,"下列关于区域型火灾报警控制器的保养内容与要求说法错误的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"检查区域型火灾报警控制器周围是否有影响其运行的遮挡物、发热设备，若有应及时移除",{"key":24,"text":113,"correct":22},"检查区域型火灾报警控制器外观是否有破损、锈蚀现象",{"key":27,"text":115,"correct":22},"使火灾探测器和手动火灾报警按钮处于报警状态，区域型火灾报警控制器应能正确显示相关报警信息",{"key":30,"text":117,"correct":32},"检查熔断器是否损坏",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},959938,"使区域型火灾报警控制器与火灾探测器之间的连线断路和短路，检查区域型火灾报警控制器是否在（ ）内发出故障信号。",[122,124,126,128],{"key":20,"text":123,"correct":22},"10s",{"key":24,"text":125,"correct":22},"30s",{"key":27,"text":127,"correct":22},"60s",{"key":30,"text":129,"correct":32},"100s",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},959939,"在故障状态下，使任一非故障部位的火灾探测器发出火灾报警信号，检查区域型火灾报警控制器是否在（ ）内发出火灾报警信号。",[134,136,137,139],{"key":20,"text":135,"correct":22},"3s",{"key":24,"text":123,"correct":32},{"key":27,"text":138,"correct":22},"20s",{"key":30,"text":125,"correct":22},{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":30,"analysis":33},959940,"使任一总线回路上不少于（ ）火灾探测器同时处于火灾报警状态，检查区域型火灾报警控制器的负载功能。",[144,146,148,150],{"key":20,"text":145,"correct":22},"4个",{"key":24,"text":147,"correct":22},"5个",{"key":27,"text":149,"correct":22},"8个",{"key":30,"text":151,"correct":32},"10个",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":30,"analysis":33},959941,"下列不属于点型感温火灾探测器保养项目的是（ ）。",[156,158,159,160],{"key":20,"text":157,"correct":22},"接线端子检查",{"key":24,"text":101,"correct":22},{"key":27,"text":103,"correct":22},{"key":30,"text":105,"correct":32},{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":30,"analysis":33},959942,"下列不属于手动火灾报警按钮保养项目的是（ ）。",[165,166,167,168],{"key":20,"text":99,"correct":22},{"key":24,"text":101,"correct":22},{"key":27,"text":103,"correct":22},{"key":30,"text":105,"correct":32},{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":27,"analysis":33},959943,"下列关于火灾报警装置启动功能测试的说法正确的是（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"启动火灾警报装置，观察声、光指示正常，并且在其正前方3m水平处，使用声级计测量声信号，应满足70-120dB（A计权）",{"key":24,"text":176,"correct":22},"启动火灾警报装置，观察声、光指示正常，并且在其正前方5m水平处，使用声级计测量声信号，应满足70-120dB（A计权）",{"key":27,"text":178,"correct":32},"启动火灾警报装置，观察声、光指示正常，并且在其正前方3m水平处，使用声级计测量声信号，应满足75-120dB（A计权）",{"key":30,"text":180,"correct":22},"启动火灾警报装置，观察声、光指示正常，并且在其正前方5m水平处，使用声级计测量声信号，应满足75-120dB（A计权）",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":20,"analysis":33},959944,"乙级防火门的表示方法是（ ）。",[185,187,189,191],{"key":20,"text":186,"correct":32},"A1.00（乙级）",{"key":24,"text":188,"correct":22},"B1.00（乙级）",{"key":27,"text":190,"correct":22},"C1.00（乙级）",{"key":30,"text":192,"correct":22},"1.00（乙级）",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":20,"analysis":33},959945,"丙级防火门的表示方法是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":32},"A0.50（丙级）",{"key":24,"text":200,"correct":22},"B0.50（丙级）",{"key":27,"text":202,"correct":22},"C0.50（丙级）",{"key":30,"text":204,"correct":22},"0.50（丙级）",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":30,"analysis":33},959946,"防火卷帘用卷门机设有自动限位装置即限位器。当防火卷帘启、闭至上、下限位时，应自动停止，其重复定位误差应小于（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"1mm",{"key":24,"text":212,"correct":22},"5mm",{"key":27,"text":214,"correct":22},"10mm",{"key":30,"text":216,"correct":32},"20mm",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":27,"analysis":33},959947,"双轨双帘防火卷帘的两个帘面应同时升降，帘面应匀速运行，两个帘面之间的高度差不应大于（ ）。",[221,222,223,225],{"key":20,"text":214,"correct":22},{"key":24,"text":216,"correct":22},{"key":27,"text":224,"correct":32},"50mm",{"key":30,"text":226,"correct":22},"60mm",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":24,"analysis":33},959948,"拉动手动速放装置手动速放启动防火卷帘自重下降时，启动下降臂力不应大于（ ）。",[231,233,235,237],{"key":20,"text":232,"correct":22},"50N",{"key":24,"text":234,"correct":32},"70N",{"key":27,"text":236,"correct":22},"80N",{"key":30,"text":238,"correct":22},"85N",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":27,"analysis":33},959949,"进水管上控制阀门应（ ）检查一次，核实其处于全开启状态。",[243,245,247,249],{"key":20,"text":244,"correct":22},"每日",{"key":24,"text":246,"correct":22},"每月",{"key":27,"text":248,"correct":32},"每季度",{"key":30,"text":250,"correct":22},"每年",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":24,"analysis":33},959950,"（ ）对铅封、锁链进行一次检查，当有损坏或破坏时应及时修理或更换。",[255,256,257,258],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":32},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":22},{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":30,"analysis":33},959951,"消火栓箱（ ）检查报警控制线路，指示灯、消火栓报警按钮应完好。",[263,264,265,266],{"key":20,"text":246,"correct":22},{"key":24,"text":248,"correct":22},{"key":27,"text":250,"correct":22},{"key":30,"text":244,"correct":32},{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":30,"analysis":33},959952,"下列关于消防软管卷盘的保养方法说法错误的是（ ）。",[271,273,275,277],{"key":20,"text":272,"correct":22},"每半年至少进行一次全面的检查维修",{"key":24,"text":274,"correct":22},"定期更换损坏或不能运行的组件",{"key":27,"text":276,"correct":22},"对消防软管卷盘的转动机构加注润滑油",{"key":30,"text":278,"correct":32},"每年至少进行一次全面的检查维修",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":30,"analysis":33},959953,"下列关于轻便消防水龙的保养方法说法错误的是（ ）。",[283,284,285,286],{"key":20,"text":272,"correct":22},{"key":24,"text":274,"correct":22},{"key":27,"text":276,"correct":22},{"key":30,"text":278,"correct":32},{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":20,"analysis":33},959954,"（ ）检查水泵接合器与墙壁之间的通道是否通畅（墙壁式水泵接合器除外），如有垃圾、杂物，需及时清除。",[291,292,293,294],{"key":20,"text":244,"correct":32},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":22},{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":20,"analysis":33},959955,"（ ）检查消防水泵接合器的接口及配套附件是否完好，目测有无渗漏，闷盖是否盖好。",[299,300,301,302],{"key":20,"text":244,"correct":32},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":22},{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":20,"analysis":33},959956,"（ ）检查地下式水泵接合器的标识是否完整，如已被移除，需及时补上。",[307,308,309,310],{"key":20,"text":244,"correct":32},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":22},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":27,"analysis":33},959957,"（ ）检查地下式水泵接合器的阀门井，及时清除阀门井内的垃圾与杂物，确保水泵接合器能够正常使用。",[315,316,317,319],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":22},{"key":27,"text":318,"correct":32},"每周",{"key":30,"text":250,"correct":22},{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":24,"analysis":33},959958,"（ ）应对消防水池、高位消防水箱等消防水源设施的水位进行一次检测",[324,325,326,327],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":32},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":22},{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":27,"analysis":33},959959,"（ ）应检查承重结构、孔口、基础、检修通道或梯子的明显损害或破损。",[332,333,334,335],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":32},{"key":30,"text":250,"correct":22},{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":30,"analysis":33},959960,"消防水池、消防水箱阴极保护（ ）按设计要求维修检查一次。",[340,341,342,343],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":32},{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},959961,"一般对灭火器的检查保养周期为（ ）进行一次。",[348,349,350,351],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":32},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":22},{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":20,"analysis":33},959962,"下列场所配置的灭火器不属于应每半月进行一次的是（ ）。",[356,358,360,362],{"key":20,"text":357,"correct":32},"办公室",{"key":24,"text":359,"correct":22},"候车（机、船）室",{"key":27,"text":361,"correct":22},"歌舞厅",{"key":30,"text":363,"correct":22},"放映厅",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":27,"analysis":33},959963,"下列不属于消防应急灯具外观检查维护保养内容的是（ ）。",[368,370,372,374],{"key":20,"text":369,"correct":22},"检查灯具的指示灯是否指示正常",{"key":24,"text":371,"correct":22},"检查标志灯的标识信息是否完整，在两个相邻标志灯具之间位置观察灯具面板的标识信息是否完整、是否可清晰辨识",{"key":27,"text":373,"correct":32},"检查灯具的安装部位是否存在漏水、渗水现象",{"key":30,"text":375,"correct":22},"对照各防火分区、楼层的疏散指示方案，检查各标志灯的标识信息（主要是疏散方向）是否与指示方案一致",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":20,"analysis":33},959964,"下列不属于按接合器公称压力分类的是（ ）。",[380,382,384,386],{"key":20,"text":381,"correct":32},"1.0MPa",{"key":24,"text":383,"correct":22},"1.6MPa",{"key":27,"text":385,"correct":22},"2.5MPa",{"key":30,"text":387,"correct":22},"4.0MPa",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":20,"analysis":33},959965,"根据其疏散指示功能的不同分类，下列不属于出口标志灯的是（ ）。",[392,394,396,398],{"key":20,"text":393,"correct":32},"多信息复合标志灯",{"key":24,"text":395,"correct":22},"安全出口标志灯",{"key":27,"text":397,"correct":22},"疏散出口标志灯",{"key":30,"text":399,"correct":22},"可变指示状态疏散出口标志灯",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":30,"analysis":33},959966,"根据其疏散指示功能的不同分类，下列不属于方向标志灯的是（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":22},"单向方向标志灯",{"key":24,"text":407,"correct":22},"双向方向标志灯",{"key":27,"text":409,"correct":22},"指示出口距离的方向标志灯",{"key":30,"text":411,"correct":32},"楼层标志等灯",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":30,"analysis":33},959967,"下列不属于按防火门材质分类的是（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"木质防火门",{"key":24,"text":419,"correct":22},"钢质防火门",{"key":27,"text":421,"correct":22},"钢木质防火门",{"key":30,"text":423,"correct":32},"门扇上带防火玻璃的防火门",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":33},959968,"下列不属于按防火门结构形式分类的是（ ）。",[428,430,431,433],{"key":20,"text":429,"correct":32},"隔热防火门",{"key":24,"text":423,"correct":22},{"key":27,"text":432,"correct":22},"带玻璃带亮窗的防火门",{"key":30,"text":434,"correct":22},"带亮窗的防火门",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":20,"analysis":33},959969,"甲级防火门的表示方法是（ ）。",[439,441,443,445],{"key":20,"text":440,"correct":32},"A1.50（甲级）",{"key":24,"text":442,"correct":22},"B1.50（甲级）",{"key":27,"text":444,"correct":22},"C1.50（甲级）",{"key":30,"text":446,"correct":22},"1.50（甲级）",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":30,"analysis":33},959970,"下列关于闭门器在投入使用后应定期检查，检查内容说法错误的是（ ）。",[451,453,455,457],{"key":20,"text":452,"correct":22},"安装螺钉是否松动或丢失",{"key":24,"text":454,"correct":22},"连接臂是否与门体或门框擦碰",{"key":27,"text":456,"correct":22},"闭门器使用时是否运转平稳、灵活",{"key":30,"text":458,"correct":32},"电动闭门器的是否损坏",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":27,"analysis":33},959971,"单帘面卷帘的两根导轨应互相平行，双帘面卷帘不同帘面的导轨也应相互平行，其平行度误差均应不大于（ ）。",[463,464,466,467],{"key":20,"text":210,"correct":22},{"key":24,"text":465,"correct":22},"3mm",{"key":27,"text":212,"correct":32},{"key":30,"text":214,"correct":22},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":24,"analysis":33},959972,"温控释放装置是利用动作温度为（ ）℃的感温元件控制防火卷帘依靠自重下降的装置。温控释放装置动作后，防火卷帘应自动下降至全闭。",[472,474,476,478],{"key":20,"text":473,"correct":22},"75±0.3",{"key":24,"text":475,"correct":32},"73±0.5",{"key":27,"text":477,"correct":22},"75±0.5",{"key":30,"text":479,"correct":22},"73±0.3",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":27,"analysis":33},959973,"下列关于防火卷帘帘面及导轨的保养说法错误的是（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":22},"无机纤维复合帘面所选用的纺织物不应有撕裂、缺角、跳线、断线、挖补及色差等缺陷",{"key":24,"text":487,"correct":22},"及时查看并清理防火卷帘的导轨，保持内部清洁，保持导轨运行畅通。帘面在导轨内的运行应平稳顺畅，不应有脱轨和明显的倾斜现象",{"key":27,"text":489,"correct":32},"双轨双帘防火卷帘的两个帘面应同时升降，帘面应匀速运行，两个帘面之间的高度差不应大于20mm",{"key":30,"text":491,"correct":22},"防火卷帘的下部不要放置任何障碍物",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":27,"analysis":33},959974,"消火栓箱（ ）至少进行一次全面的检查维修。",[496,497,498,500],{"key":20,"text":246,"correct":22},{"key":24,"text":248,"correct":22},{"key":27,"text":499,"correct":32},"每半年",{"key":30,"text":250,"correct":22},{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":20,"analysis":33},959975,"（ ）检查消防水泵接合器控制阀门，按照阀门开启标识开启和关闭阀门各一次，如发现异常，应及时维修或更换。",[505,506,507,508],{"key":20,"text":244,"correct":32},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":22},{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":20,"analysis":33},959976,"下列关于消防水泵接合器组件的安装顺序说法正确的是（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":32},"接口、本体、连接管、止回阀、安全阀、放空阀、控制阀",{"key":24,"text":516,"correct":22},"接口、本体、连接管、止回阀、放空阀、控制阀、安全阀",{"key":27,"text":518,"correct":22},"接口、本体、连接管、止回阀、控制阀、安全阀、放空阀",{"key":30,"text":520,"correct":22},"接口、本体、连接管、安全阀、止回阀、放空阀、控制阀",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":30,"analysis":33},959977,"（ ）应检查消防水池、消防水箱等蓄水设施的结构材料是否完好，发现问题及时处理。",[525,526,527,528],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":32},{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":30,"analysis":33},959978,"消防水池、消防水箱进出水管上的阀门（ ）检查一次。伸缩接头每年检查是否漏水或破裂。",[533,534,535,536],{"key":20,"text":244,"correct":22},{"key":24,"text":246,"correct":22},{"key":27,"text":248,"correct":22},{"key":30,"text":250,"correct":32},{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":20,"analysis":33},959979,"对于翻盖式的灭火器，翻盖开启角度应不小于（ ）。",[541,543,545,547],{"key":20,"text":542,"correct":32},"100°",{"key":24,"text":544,"correct":22},"150°",{"key":27,"text":546,"correct":22},"165°",{"key":30,"text":548,"correct":22},"175°",[550,553,556,559,562,565],{"id":15,"name":551,"category":7,"favorite":552},"领导干部任职前廉政法规知识测试题",92,{"id":554,"name":555,"category":7,"favorite":15},595,"建筑结构与设备",{"id":557,"name":558,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":560,"name":561,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":563,"name":564,"category":7,"favorite":8},534,"BIM工程师",{"id":566,"name":564,"category":7,"favorite":8},535]