[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":593},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,3,50,1301,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,310,322,334,346,356,366,378,389,401,413,425,437,449,461,472,484,496,508,520,532,544,553,561,569,577,585],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},959829,1,"单选题","火灾报警控制器的备用电源在放电至终止电压条件下充电24h，其容量应可提供火灾报警控制器在监视状态下工作8h后，在火灾报警控制器容量不超过10个报警部位时，所有报警部位均处于报警状态条件下工作（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","30min",true,{"key":24,"text":25,"correct":26},"B","60min",false,{"key":28,"text":29,"correct":26},"C","90min",{"key":31,"text":32,"correct":26},"D","120min","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},959830,"若火灾报警控制器处于主电故障，且备用电源已经不能保证火灾报警控制器正常工作时，火灾报警控制器持续发出声故障信号并能保持（ ）以上，声故障信号无法手动消除，则判断火灾报警控制器处于备电欠压故障状态。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1.0h",{"key":24,"text":41,"correct":26},"3.0h",{"key":28,"text":43,"correct":26},"4.0h",{"key":31,"text":45,"correct":26},"8.0h",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},959831,"下列关于火灾报警控制器的检查内容说法错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"指示灯：自检时面板所有指示灯均能被点亮及熄灭，自检后指示灯恢复原状态",{"key":24,"text":53,"correct":26},"显示器：对于彩色液晶类显示器件，应能通过红、绿、蓝等颜色刷屏，保证各像素点完整",{"key":28,"text":55,"correct":22},"显示器：对于单色液晶类显示器件，应点亮所有码段，不能缺划",{"key":31,"text":57,"correct":26},"音响器：对于音响类器件，自检时扬声器应能依次发出火警、监管、故障等声音，监管和故障声音应与火警声音明显区分",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},959832,"下列关于火灾报警控制器现场部件的检查内容说法错误的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"火灾报警控制器自检总指示灯（器）：当系统中存在处于自检状态的设备时，此灯熄灭；所有设备退岀自检状态后，此灯熄灭点亮",{"key":24,"text":65,"correct":26},"现场部件指示灯：下发自检命令后，检查现场部件的报警、动作、反馈、故障等指示灯是否能被点亮",{"key":28,"text":67,"correct":26},"现场部件显示功能：下发自检命令后，观察具有液晶或数码管显示的设备显示是否正常",{"key":31,"text":69,"correct":26},"现场部件报警功能：下发自检命令后，检查现场部件是否能够报警并正确上传",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},959833,"下列灭火器不使用于带电设备火灾的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"BC干粉型灭火器",{"key":24,"text":77,"correct":26},"ABC干粉型灭火器",{"key":28,"text":79,"correct":22},"D型干粉型灭火器",{"key":31,"text":81,"correct":26},"二氧化碳灭火器",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},959834,"下列关于灭火器压力指示器标识的说法错误的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"干粉型灭火器的压力指示器标识为F",{"key":24,"text":89,"correct":26},"水基型灭火器压力指示器的标识为S",{"key":28,"text":91,"correct":26},"洁净气体灭火器压力指示器的标识为J",{"key":31,"text":93,"correct":22},"二氧化碳气体灭火器压力指示器的标识为T",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},959835,"下列关于灭火器外部可视零部件的功能说法错误的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"压力指示器是显示灭火器筒体内压力的元件",{"key":24,"text":101,"correct":26},"保险装置是防止误操作的部件",{"key":28,"text":103,"correct":26},"封记是用于识别灭火器是否被启用过的部件",{"key":31,"text":105,"correct":22},"喷嘴（或喇叭筒）是用于为灭火剂喷射流导向和改变射流状态的部件",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},959836,"下列关于过滤式消防自救呼吸器防护头罩性能要求的说法错误的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"防护头罩眼区的漏气系数应不大于20%，呼吸区的漏气系数应不大于5%",{"key":24,"text":113,"correct":26},"若呼吸器中不设半面罩，则防护头罩的漏气系数应不大于5%",{"key":28,"text":115,"correct":26},"防护头罩的总视野应不小于70%，双目视野应不小于55%，下方视野应不小于35%",{"key":31,"text":117,"correct":22},"吸入气体中二氧化碳的体积分数应不大于2%；视窗的透光率应不小于80%",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},959837,"下列关于化学氧消防自救呼吸器贮气袋有效容积的说法正确的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"贮气袋有效容积应不小于1L",{"key":24,"text":125,"correct":26},"贮气袋有效容积应不小于3L",{"key":28,"text":127,"correct":22},"贮气袋有效容积应不小于6L",{"key":31,"text":129,"correct":26},"贮气袋有效容积应不小于10L",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},959838,"为了防止发生火灾时人员被困，防火卷帘控制器还具有逃生功能，即当火灾发生时，若卷帘处在中位下，手动操作控制器上任意一个按钮，防火卷帘应能自动开启至中位，延时（ ）后继续关至全闭。",[134,136,138,140],{"key":20,"text":135,"correct":26},"2～60s",{"key":24,"text":137,"correct":22},"5～60s",{"key":28,"text":139,"correct":26},"5～90s",{"key":31,"text":141,"correct":26},"2～90s",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},959839,"防火卷帘还具有温控释放装置，可实现在无电、无人的情况下，当环境温度升高到（ ）时，温控元件（易熔金属或闭式玻璃球）熔化或爆裂，帘体失去限位控制而靠自重释放至关闭，实现防火分隔作用。",[146,148,150,152],{"key":20,"text":147,"correct":22},"（73±0.5）℃",{"key":24,"text":149,"correct":26},"（70±0.5）℃",{"key":28,"text":151,"correct":26},"（73±0.3）℃",{"key":31,"text":153,"correct":26},"（70±0.3）℃",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},959840,"下列关于消防闸阀的基本性能说法正确的是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"对刚性非金属零件分别进行热空气老化、温水老化试验，试验后刚性非金属零件不应产生妨碍装置正常动作的扭曲、蠕变、裂纹或其他变形损坏",{"key":24,"text":161,"correct":26},"闸阀阀板处于关闭状态位置时，进水口应能承受4倍于额定工作压力的静水压，保持5min，阀门各密封处应无渗漏",{"key":28,"text":163,"correct":26},"闸阀应能承受2倍于额定工作压力的静水压，保持5min，试验时闸板应全开，试验后阀体应无渗漏、变形和损坏",{"key":31,"text":165,"correct":26},"手轮应采用锁紧螺母固定在阀杆上，其外缘直径不大于规定值",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},959841,"下列关于自动排气阀型号FGP4-X-150-10-Q的表示正确的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":26},"表示阀体材质为球墨铸铁，公称压力为1.0MPa，公称直径为150mm、密封材料为橡胶、螺纹连接的给水管道自动排气阀",{"key":24,"text":173,"correct":26},"表示阀体材质为球墨铸铁，公称压力为1.5MPa，公称直径为100mm、密封材料为橡胶、法兰连接的给水管道自动排气阀",{"key":28,"text":175,"correct":22},"表示阀体材质为球墨铸铁，公称压力为1.0MPa，公称直径为150mm、密封材料为橡胶、法兰连接的给水管道自动排气阀",{"key":31,"text":177,"correct":26},"表示阀体材质为球墨铸铁，公称压力为1.5MPa，公称直径为100mm、密封材料为橡胶、螺纹连接的给水管道自动排气阀",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},959842,"下列关于蝶阀型号DF-8-Q-100-16的表示正确的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":26},"表示公称直径为100mm，额定工作压力不低于1.6MPa的气动消防蝶阀，材质为球墨铸铁，连接方式为沟槽连接",{"key":24,"text":185,"correct":26},"表示公称直径为100mm，额定工作压力不低于1.6MPa的手动消防蝶阀，材质为球墨铸铁，连接方式为法兰连接",{"key":28,"text":187,"correct":22},"表示公称直径为100mm，额定工作压力不低于1.6MPa的手动消防蝶阀，材质为球墨铸铁，连接方式为沟槽连接",{"key":31,"text":189,"correct":26},"表示公称直径为100mm，额定工作压力不低于1.6MPa的手动消防蝶阀，材质为碳钢，连接方式为沟槽连接",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},959843,"下列对于金属密封结构，允许渗漏量不大于最大流量的（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"0.5%",{"key":24,"text":197,"correct":26},"1.0%",{"key":28,"text":199,"correct":26},"5.0%",{"key":31,"text":201,"correct":26},"10.0%",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},959844,"下列止回阀的基本性能中压力损失的说法正确的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"止回阀压力损失：水流速为1m\u002Fs时，最大允许压力损失应不大于40KPA",{"key":24,"text":209,"correct":22},"止回阀压力损失：水流速为2m\u002Fs时，最大允许压力损失应不大于40KPA",{"key":28,"text":211,"correct":26},"止回阀压力损失：水流速为1m\u002Fs时，最大允许压力损失应不大于50KPA",{"key":31,"text":213,"correct":26},"止回阀压力损失：水流速为2m\u002Fs时，最大允许压力损失应不大于50KPa",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},959845,"高位消防水箱的设置应符合下列规定，以下说法错误的有（）",[218,220,222,224],{"key":20,"text":219,"correct":26},"当高位消防水箱在屋顶露天设置时，水箱的入孔、以及进出水管的阀门等应采取锁具或阀门箱等保护措施",{"key":24,"text":221,"correct":26},"严寒、寒冷等冬季冰冻地区的消防水箱应设置在消防水箱间内，其他地区宜设置在室内，当必须在屋顶露天设置时，应采取防冻隔热等安全措施",{"key":28,"text":223,"correct":22},"严寒、寒冷等冬季冰冻地区的消防水箱应设置在消防水箱间内，其他地区宜设置在室内，当必须在屋顶露天设置时，应采取防雨防雷等安全措施",{"key":31,"text":225,"correct":26},"高位消防水箱与基础应牢固连接",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},959846,"下列关于点型感温火灾探测器的火灾报警功能的说法错误的是（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":26},"点型感温火灾探测器上设有红色报警确认灯",{"key":24,"text":233,"correct":26},"当探测器监测区域温度参数符合报警条件时，探测器报警确认灯应点亮，并保持直至被复位",{"key":28,"text":235,"correct":26},"确认灯点亮时，在其正前方6m处，在光照度不超过500lx的环境条件下，应清晰可见",{"key":31,"text":237,"correct":22},"型感温火灾探测器发出火灾报警信号后，火灾报警控制器应在60s内发出火灾报警声光信号，记录报警时间，显示发出火灾报警信号的点型感温火灾探测器的地址注释信息",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":28,"analysis":33},959847,"手动火灾报警按钮应设置在明显和便于操作的部位。当安装在墙上时，其底边距地高度宜为（ ），且应有明显的标志。",[242,244,246,248],{"key":20,"text":243,"correct":26},"1.0～1.2m",{"key":24,"text":245,"correct":26},"1.2～1.6m",{"key":28,"text":247,"correct":22},"1.3～1.5m",{"key":31,"text":249,"correct":26},"1.5～1.8m",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":33},959848,"复位操作后的火灾报警控制器将保持仍然存在的状态及相关信息或在一段时间内重新建立这些信息，但火灾报警控制器的（ ）、自检状态不受复位操作的影响。",[254,256,258,260],{"key":20,"text":255,"correct":22},"屏蔽",{"key":24,"text":257,"correct":26},"火警",{"key":28,"text":259,"correct":26},"故障",{"key":31,"text":261,"correct":26},"监管",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},959849,"下列关于火灾警报器的设置要求说法错误的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":26},"火灾光警报器应安装在安全出口附近明显处",{"key":24,"text":269,"correct":22},"当火灾警报器釆用壁挂方式安装时，其底边距地面高度为2.2m",{"key":28,"text":271,"correct":26},"火灾声警报器宜在报警区域内均匀安装",{"key":31,"text":273,"correct":26},"火灾光警报器与消防应急疏散指不标志不宜在同一面墙上，如果安装在同一面墙上时，距离应大于1m",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":31,"analysis":33},959850,"下列操作不需要对主电\u002F备电工作状态进行切换操作的是（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":26},"在对火灾自动报警系统进行季度功能检查和测试时",{"key":24,"text":281,"correct":26},"更换火灾报警控制器电源线路的熔断器时",{"key":28,"text":283,"correct":26},"按设备使用要求定期对备用电源电池进行人工充放电时",{"key":31,"text":285,"correct":22},"火灾报警控制器安装调试或维修完成时",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":31,"analysis":33},959851,"下列关于火灾报警控制器关机时的操作说法错误的是（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":26},"要注意备电开关一定要断开，否则，由于火灾报警控制器内部依然有电路工作，将导致备电放空进而可能损坏电池",{"key":24,"text":293,"correct":26},"由于火灾报警控制器使用的免维护铅酸电池存在自放电现象，需要定期充电维护，如火灾报警控制器长时间存放而不使用，应按火灾报警控制器使用说明书要求周期或每个月开机充电48h",{"key":28,"text":295,"correct":26},"如果火灾报警控制器主电断电后使用备电工作至备电保护，此时电池已放电至终止电压，需要尽快恢复主电供电并给备电电池充电不少于48h",{"key":31,"text":297,"correct":22},"如果备电放空后超过5天仍不进行充电，很可能损坏电池",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":28,"analysis":33},959852,"下列场所不适用于点型感烟火灾探测器的是（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":26},"饭店",{"key":24,"text":305,"correct":26},"旅馆",{"key":28,"text":307,"correct":22},"锅炉房",{"key":31,"text":309,"correct":26},"通信机房",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":28,"analysis":33},959853,"下列场所可以采用感烟火灾探测器的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":26},"有大量水汽滞留的场所",{"key":24,"text":317,"correct":26},"可能产生腐蚀性气体的场所",{"key":28,"text":319,"correct":22},"气流速度为3m\u002Fs的场所",{"key":31,"text":321,"correct":26},"相对湿度经常大于95%的场所",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":28,"analysis":33},959854,"当点型感温火灾探测器与火灾报警控制器处于离线状态时，火灾报警控制器应在（ ）内发出故障报警声光信号，记录故障报警时间，显示故障点型感温火灾探测器的地址注释信息。",[326,328,330,332],{"key":20,"text":327,"correct":26},"10s",{"key":24,"text":329,"correct":26},"60s",{"key":28,"text":331,"correct":22},"100s",{"key":31,"text":333,"correct":26},"120s",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":28,"analysis":33},959855,"每个防火分区应至少设置一个手动火灾报警按钮。从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离不应大于（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":26},"20m",{"key":24,"text":341,"correct":26},"25m",{"key":28,"text":343,"correct":22},"30m",{"key":31,"text":345,"correct":26},"35m",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":28,"analysis":33},959856,"火灾报警控制器需要接收来自同一探测器（区）两个或两个以上火灾报警信号才能确定发出火灾报警信号时，如果在接收到第一个火灾报警信号后的（ ）内仍未接收到要求的后续火灾报警信号，应对第一个火灾报警信号自动复位。",[350,352,354,355],{"key":20,"text":351,"correct":26},"3min",{"key":24,"text":353,"correct":26},"10min",{"key":28,"text":21,"correct":22},{"key":31,"text":25,"correct":26},{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":24,"analysis":33},959857,"当火灾报警控制器需要接收来自不同部位两只火灾探测器的火灾报警信号才能确定发出火灾报警信号时，如果在接收到第一只火灾探测器的火灾报警信号后，在规定的时间间隔不少于（ ）内未接收到要求的后续火灾报警信号，应对第一个火灾报警信号自动复位。",[360,362,364,365],{"key":20,"text":361,"correct":26},"1.0min",{"key":24,"text":363,"correct":22},"5.0min",{"key":28,"text":353,"correct":26},{"key":31,"text":21,"correct":26},{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":33},959858,"下列关于火灾警报器的选型要求说法错误的是（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"公共场所宜设置具有不同种火灾变调声的火灾声警报器",{"key":24,"text":373,"correct":26},"具有多个报警区域的保护对象，宜选用带有语音提示的火灾声警报器",{"key":28,"text":375,"correct":26},"学校不应使用警铃作为火灾声警报器",{"key":31,"text":377,"correct":26},"工厂不应使用警铃作为火灾声警报器",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":20,"analysis":33},959859,"下列关于火灾警报器釆用壁挂方式安装时，其安装高度说法正确的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"底边距地面高度应大于2.2m",{"key":24,"text":385,"correct":26},"底边距地面高度应大于2.0m",{"key":28,"text":387,"correct":26},"底边距地面高度应不小于2.2m",{"key":31,"text":387,"correct":26},{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":20,"analysis":33},959860,"下列关于火灾报警控制器开机时的操作说法错误的是（ ）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"首先开启备电开关，然后开启主电开关",{"key":24,"text":396,"correct":26},"如有联动电源和火灾显示盘，再开启联动电源和火灾显示盘的主电开关、备电开关",{"key":28,"text":398,"correct":26},"开机后火灾报警控制器显示器可显示系统初始化提示、声光检查、外接设备注册、注册结果显示等开机运行信息",{"key":31,"text":400,"correct":26},"开机界面因设备的生产厂商不同会存在差异，完成后如无报警和屏蔽信息即进入正常监视状态",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":33},959861,"下列不属于消防水源的是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":26},"市政给水管网",{"key":24,"text":408,"correct":26},"消防水池",{"key":28,"text":410,"correct":22},"水泵接合器",{"key":31,"text":412,"correct":26},"高位消防水箱",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":31,"analysis":33},959862,"下列不属于消火栓箱组成部分的是（ ）。",[417,419,421,423],{"key":20,"text":418,"correct":26},"消防接口",{"key":24,"text":420,"correct":26},"消防水带",{"key":28,"text":422,"correct":26},"电气设备",{"key":31,"text":424,"correct":22},"消防消防官网",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":24,"analysis":33},959863,"消防水枪的工作压力为2.0MPa，按消防水枪的工作压力分类属于（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":26},"低压水枪",{"key":24,"text":432,"correct":22},"中压水枪",{"key":28,"text":434,"correct":26},"高压水枪",{"key":31,"text":436,"correct":26},"超高压水枪",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":28,"analysis":33},959864,"下列不属于按衬里材料分类的是（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":26},"橡胶消防软管",{"key":24,"text":444,"correct":26},"聚氨酯消防软管",{"key":28,"text":446,"correct":22},"内外涂层消防软管",{"key":31,"text":448,"correct":26},"PVC消防软管",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":33},959865,"下列关于轻便消防水龙的型号LQG1O-30的表示意义正确的是（ ）。",[453,455,457,459],{"key":20,"text":454,"correct":22},"表示消防供水管用，设计工作压力为1.0MPa，水带长度为30m的轻便消防水龙",{"key":24,"text":456,"correct":26},"表示消防供水管用，设计工作压力为3.0MPa，水带长度为10m的轻便消防水龙",{"key":28,"text":458,"correct":26},"表示消防供水管用，设计工作压力为0.1MPa，水带长度为30m的轻便消防水龙",{"key":31,"text":460,"correct":26},"表示消防供水管用，设计工作压力为0.3MPa，水带长度为10m的轻便消防水龙",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":24,"analysis":33},959866,"将轻便消防水龙灌满水排净空气后关闭喷枪，缓慢升至设计工作压力，保压（ ），检查水龙各密封部位，应无渗漏、变形和脱落现象。",[465,467,469,470],{"key":20,"text":466,"correct":26},"1min",{"key":24,"text":468,"correct":22},"2min",{"key":28,"text":351,"correct":26},{"key":31,"text":471,"correct":26},"5min",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":31,"analysis":33},959867,"轻便消防水龙的水带单位长度质量应不超过（ ）。",[476,478,480,482],{"key":20,"text":477,"correct":26},"120g\u002Fm",{"key":24,"text":479,"correct":26},"150g\u002Fm",{"key":28,"text":481,"correct":26},"160g\u002Fm",{"key":31,"text":483,"correct":22},"180g\u002Fm",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":20,"analysis":33},959868,"轻便消防水龙卡式专用接口与水龙头的操作力应在（ ）范围内。",[488,490,492,494],{"key":20,"text":489,"correct":22},"30～90N",{"key":24,"text":491,"correct":26},"50～90N",{"key":28,"text":493,"correct":26},"30～80N",{"key":31,"text":495,"correct":26},"50～80N",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":31,"analysis":33},959869,"下列不属于消防水泵按照提供压力分类的是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":26},"低压消防水泵",{"key":24,"text":503,"correct":26},"中压消防水泵",{"key":28,"text":505,"correct":26},"高压消防水泵",{"key":31,"text":507,"correct":22},"超高压消防水泵",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":20,"analysis":33},959870,"下列建筑应设置备用泵的是（ ）。",[512,514,516,518],{"key":20,"text":513,"correct":22},"建筑高度为54m的住宅",{"key":24,"text":515,"correct":26},"室外消防给水设计流量为25L\u002Fs的建筑",{"key":28,"text":517,"correct":26},"室内消防给水设计流量为10L\u002Fs的建筑",{"key":31,"text":519,"correct":26},"室外消防给水设计流量为20L\u002Fs的建筑",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":24,"analysis":33},959871,"消防水泵应保证在火灾发生后的规定时间内正常工作，当为自动启动时，消防水泵从接到启泵信号到水泵正常运转的时间应在（ ）min内。",[524,526,528,530],{"key":20,"text":525,"correct":26},"1",{"key":24,"text":527,"correct":22},"2",{"key":28,"text":529,"correct":26},"3",{"key":31,"text":531,"correct":26},"5",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},959872,"（ ）应对稳压泵的停泵、启泵压力和启泵次数等进行检查，并记录运行情况。",[536,538,540,542],{"key":20,"text":537,"correct":22},"每日",{"key":24,"text":539,"correct":26},"每月",{"key":28,"text":541,"correct":26},"每季",{"key":31,"text":543,"correct":26},"每年",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":24,"analysis":33},959873,"（ ）消防水泵运行前，检查泵组是否完好。",[548,549,551,552],{"key":20,"text":537,"correct":26},{"key":24,"text":550,"correct":22},"每周",{"key":28,"text":541,"correct":26},{"key":31,"text":539,"correct":26},{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":24,"analysis":33},959874,"（ ）消防水泵运行前，检查电气控制部分是否完好。",[557,558,559,560],{"key":20,"text":537,"correct":26},{"key":24,"text":550,"correct":22},{"key":28,"text":541,"correct":26},{"key":31,"text":539,"correct":26},{"id":562,"libraryId":5,"type":15,"typeLabel":16,"stem":563,"options":564,"answer":31,"analysis":33},959875,"（ ）应手动启动消防水泵运转一次，并应检查供电电源的情况。",[565,566,567,568],{"key":20,"text":537,"correct":26},{"key":24,"text":550,"correct":26},{"key":28,"text":541,"correct":26},{"key":31,"text":539,"correct":22},{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},959876,"（ ）应检测消防水泵自动记录的自动巡检情况。",[573,574,575,576],{"key":20,"text":537,"correct":26},{"key":24,"text":539,"correct":22},{"key":28,"text":541,"correct":26},{"key":31,"text":543,"correct":26},{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":28,"analysis":33},959877,"（ ）应对消防水泵的岀水流量和压力进行一次试验。",[581,582,583,584],{"key":20,"text":537,"correct":26},{"key":24,"text":539,"correct":26},{"key":28,"text":541,"correct":22},{"key":31,"text":543,"correct":26},{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":20,"analysis":33},959878,"消防水泵控制柜应设置手动机械启泵功能，并应保证在控制柜内的控制线路发生故障时由有管理权限的人员在紧急时启动消防水泵。手动启泵时消防水泵应在报警（ ）内正常工作。",[589,590,591,592],{"key":20,"text":471,"correct":22},{"key":24,"text":351,"correct":26},{"key":28,"text":468,"correct":26},{"key":31,"text":466,"correct":26},[594,597,600,603,606,609],{"id":15,"name":595,"category":7,"favorite":596},"领导干部任职前廉政法规知识测试题",92,{"id":598,"name":599,"category":7,"favorite":15},595,"建筑结构与设备",{"id":601,"name":602,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":604,"name":605,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":607,"name":608,"category":7,"favorite":8},534,"BIM工程师",{"id":610,"name":608,"category":7,"favorite":8},535]