[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,25,50,1301,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},961080,3,"判断题","值班情况记录由值班人员填写值班的时间段，由接班人员进行确认。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},961081,"火灾报警控制器按系统连线方式分为多线制火灾报警控制器、总线制火灾报警控制器及无线火灾报警控制器。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},961082,"对于建筑规模较大、报警点数多的具有火灾报警和联动控制功能的火灾自动报警系统，消防控制室设备一般由火灾报警控制器、消防联动控制器、消防控制室图形显示装置、火灾应急广播和消防电话总机等设备构成。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},961083,"火灾报警控制器接收到报警信号后，先消音然后将控制器复位即可。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},961084,"手动火灾报警按钮按照其触发方式可分为两种一种是玻璃破碎按钮，另一种是可复位报警按钮。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},961085,"碳酸氢钠干粉灭火器，又叫ABC类干粉灭火器，用于灭液体、气体火灾。",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},961086,"手提式干粉灭火器的规格有1kg、2kg、3kg、4kg、5kg、6kg、8kg、9kg、12kg。",[62,63],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},961104,"疏散指示标志是指用于火灾时人员安全疏散时有指示作用的标志。",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},961105,"安装喷头的位置不得设置影响喷头布水性能的障碍物，当发现喷头周围有影响喷头动作或洒水的障碍物时，应立即进行清除。",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},961106,"泡沫液按发泡机制不同分为化学泡沫液和空气泡沫液。",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},961109,"SA65\u002F65-1.6表示出水口为100mm和65mm、公称压力为1.6MPa的地上消火栓。",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":21,"analysis":27},961110,"防火门按开启状态分为常闭防火门和常开防火门。",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},961111,"消防应急照明在正常电源断电后，其电源转换时间应满足①疏散照明≤5s；②备用照明≤5s（金融商业交易场所≤1.5s）。",[98,99],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},961112,"气体灭火系统按储存压力可分为高压灭火系统和低压灭火系统。",[104,105],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},961113,"疏散指示标志灯，一般设在距地面不超过1m的墙上，千万不可设在顶棚吊顶上。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},961114,"为了安全有效地使用应急照明，应定期进行外观清扫、检查，对于外观破损的应进行更换。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},961115,"储压式灭火器应采用测压法检验泄漏量。灭火器每年的压力降低值不应大于工作压力的10%。",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},961116,"非编码型可直接接人火灾报警控制器的信号二总线（需要电源系统提供二根DC24Ⅴ电源线），编码型可直接由有源DC24Ⅴ常开触点进行控制。",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},961117,"消防水带分为通用消防水带、消防湿水带、抗静电、水幕消防水带几种。",[134,135],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},961118,"室外消火栓按其进水口连接形式可分为承插式和法兰式两种。",[140,141],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},961120,"手动火灾报警按钮的作用是确认火情和人工发出火警信号。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},961124,"二氧化碳储气瓶用称重法检验泄漏量",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},961131,"末端试水装置可以检测干式系统和预作用系统充水时间。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},961132,"下垂型喷头下垂安装，水流向下冲向溅水盘的喷头。",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},961135,"专用电话采用直接呼叫通话方式，无需拨号。",[170,171],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},961136,"二氧化碳灭火器的年泄漏量不应大于灭火器额定充装量的10%或100g（取两者的小值）。",[176,177],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":25,"analysis":27},961137,"常开防火门在发生火灾时需靠手动关闭。",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},961138,"气体灭火系统防护区应有能在60s内使该区域人员疏散完毕的走道与出口。",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":25,"analysis":27},961139,"泡沫灭火系统按泡沫产生倍数的不同，分为高倍数及低倍数两种系统。",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},961140,"建筑消防设施一般可分为可移动（或非固定）消防设施和固定消防设施。",[200,201],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},961141,"室外消火栓按其出水口型式可分为单出水口消火栓和双出水口消火栓。",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":25,"analysis":27},961142,"手动报警按钮是通过自动启动器件发出火灾报警信号的装置。",[212,213],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":21,"analysis":27},961143,"直立型喷头是直立安装，水流向上冲向溅水盘的喷头。",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},961144,"干粉灭火器适用于扑救易燃液体、可燃气体和电气设备的初起火灾。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},961145,"气体灭火系统一般具有自动控制、手动控制、机械应急操作三种启动方式。",[230,231],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},961146,"一般易燃固体物质初起火灾可用水、湿棉被、湿麻袋、黄沙、水泥粉等扑救。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},961147,"使用的应急灯具，不得让水进入灯体，如有水应及时清除。清除时不需切断电源。",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},961148,"空气泡沫枪用以扑灭小型油罐、地面石油和石油类产品等B类火灾及木材等一般固体物质火灾。",[248,249],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},961149,"应急广播系统的扬声器一般分为壁挂式和吸顶式两种。",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":25,"analysis":27},961150,"泡沫系统设备由通用设备和专用设备组成。专用设备主要是消防水泵和报警控制等；通用设备是泡沫比例混合设备和泡沫产生设备。",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":27},961151,"在民用建筑里，扬声器应设置在走道和大厅等公共场所，每个扬声器的功率不小于5W。",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},961152,"消火栓箱按安装方式可分为明装式、暗装式及半暗装式。",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":21,"analysis":27},961153,"在常压下，液态的二氧化碳会立即汽化，一般1kg的液态二氧化碳可产生约0.5立方米的气体。",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},961154,"末端试水装置由试水阀、压力表以及洒水喷头等组成。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":27},961155,"特殊响应喷头响应时间系数（RTI）小于或等于50（m·s）0.5且传导系数（C）小于或等于1.0（m·s）0.5的喷头。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":21,"analysis":27},961156,"手动报警按钮的维护要点是对玻璃器件的保护。日常情况下，需要配有专用的测试工具，用于在不击碎玻璃的情况下进行维护和测试。",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":25,"analysis":27},961157,"更换洒水喷头时应使用活动扳手，不得利用喷头轭臂进行安装与拆卸。",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},961158,"气体灭火系统是以某些气体作为灭火介质，通过这些气体在整个防护区内或保护对象周围的局部区域建立起灭火剂浓度实现灭火的。",[308,309],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},961159,"空气泡沫灭火剂主要由蛋白类泡沫灭火剂和合成类泡沫灭火剂组成。",[314,315],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},961160,"油锅、油桶、油盘着火，可用锅盖、铁板、湿棉被、湿麻袋等灭火。",[320,321],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[323,327,330,333,336,339],{"id":324,"name":325,"category":7,"favorite":326},1,"领导干部任职前廉政法规知识测试题",92,{"id":328,"name":329,"category":7,"favorite":324},595,"建筑结构与设备",{"id":331,"name":332,"category":7,"favorite":324},715,"招标采购专业知识与法律法规",{"id":334,"name":335,"category":7,"favorite":324},848,"市政方向-通用基础",{"id":337,"name":338,"category":7,"favorite":8},534,"BIM工程师",{"id":340,"name":338,"category":7,"favorite":8},535]