[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,20,50,1301,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},960793,3,"判断题","每月消防水泵运行前，检查主电源、备用电源切换是否正常；检查备用电源，应保证在30s内使水泵投入正常运行，检查备用水泵能否自动切换投入运行。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},960794,"每月应模拟消防水泵自动控制的条件自动启动消防水泵运转一次，且应自动记录自动巡检情况。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},960795,"每日应检查储油箱的储油量。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},960796,"每周应手动启动消防水泵运转一次，并应检查供电电源的情况。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":25,"analysis":27},960797,"每周应检测消防水泵自动记录的自动巡检情况。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},960798,"每周应手动启动柴油机消防水泵运行一次。",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},960799,"每月应对气压水罐的压力和有效容积等进行一次检测。",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},960800,"每年应对消防水泵的岀水流量和压力进行一次试验。",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":25,"analysis":27},960801,"消防水泵控制柜在平时应使消防水泵处于手动启泵状态。",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":25,"analysis":27},960802,"MT\u002F3：3L手提式二氧化碳灭火器。",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":21,"analysis":27},960803,"MSTZ\u002FAR45：45L推车贮压式抗溶性水剂灭火器。",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},960804,"所有的灭火器不能倒置使用，且避免在倾角大于45°时使用，以防止增大灭火剂的剩余量。",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},960805,"对于极性液体燃料（如甲醇、乙醍、丙酮等）火灾，只能使用抗溶性水基型灭火器。",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},960806,"水基型灭火器一般不适用于扑灭涉及带电设备的火灾，除非装配特殊喷雾喷嘴的，经电绝缘性能试验证实有效后，才可用于扑灭涉及带电设备的火灾。",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},960807,"干粉的粉雾对人的呼吸道有刺激作用，喷射干粉后，使用者应迅速撤离，特别是在有限空间内的人员，在喷射干粉时应及时撤离。",[110,111],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":25,"analysis":27},960808,"扑救油类火灾时，干粉灭火剂的抗复燃性较好。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},960809,"二氧化碳灭火器的抗复燃性好。",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},960810,"不宜在室外有大风或室内有强烈空气对流处使用洁净气体灭火器，否则气体会快速被吹散而影响灭火效果。",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},960811,"气体灭火剂的抗复燃性差。",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},960812,"目前所有的灭火器不能倒置使用，且避免在倾角大于45°时使用，以防止增大灭火剂的剩余量。",[140,141],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},960813,"手动启停消防水泵时，将消防水泵控制柜控制开关转至手动，按下控制柜上一键启动按钮，观察消防水泵是否按时启动且运行平稳。按下控制柜上一键停止按钮，观察消防水泵是否平稳停止。",[146,147],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},960814,"消防水泵控制柜柜门不能上锁，便于巡查人员随时观看控制柜运行状态。",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":25,"analysis":27},960815,"轻便消防水龙仅在自来水管上使用的一种小型、简便的喷水灭火器具。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},960816,"化学氧消防自救呼吸器仅供一次性使用，不能用于作业保护和水下使用。",[164,165],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},960817,"大多数洁净气体灭火剂灭火后产生的热分解气体都有一定的毒性，在室内使用时，喷射结束后人员应迅速撤离。",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},960818,"在现场环境具有较大背景噪声时，宜使用火灾声警报器。",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":25,"analysis":27},960819,"火灾报警控制器消音、复位操作过程中，如存在本机故障或与其连接的部件间发生故障时，还应规范填写消防控制室值班记录表。",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},960820,"除化学氧消防自救呼吸器以外，消防自救呼吸器在使用过程中不得随意摘除。",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},960821,"过滤式消防自救呼吸器仅供成年人佩戴逃生用，过滤式消防自救呼吸器在使用过程中不得随意摘除。",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},960822,"火灾报警控制器电源部分由主电和备用电源组成，两者均具有手动控制开关，且能进行自动转换。",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":25,"analysis":27},960823,"室外消火栓给水系统是建（构）筑物应用最广泛的一种灭火设施。",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":25,"analysis":27},960824,"室外消火栓操作，连接消防水带和室外消火栓出水口后，用室外消火栓扳手顺时针旋转，把螺杆旋到最大位置，打开室外消火栓，对准火焰灭火。（ ）",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":21,"analysis":27},960825,"检查区域型火灾报警控制器周围是否有影响其运行的遮挡物、发热设备，若有应及时移除。",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},960826,"检查区域型火灾报警控制器外观是否有破损、锈蚀现象。当设备外观有破损情况时，应及时更换区域型火灾报警控制器。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},960827,"检查区域型火灾报警控制器的接线端子，将松动的端子重新紧固连接；换掉有锈蚀痕迹的螺钉、端子垫片等接线部件；去除有锈蚀的导线端，镀锡后重新连接。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},960828,"检查区域型火灾报警控制器备用电池外观，不应有裂纹、变形及爬碱、漏液等现象，电池闲置不用时，应每季度充电一次，以延长电池使用寿命。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},960829,"检查熔断器外观是否有损伤、变形，如有应及时更换熔断器。",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},960830,"使区域型火灾报警控制器与备用电源之间的连线断路和短路，检查区域型火灾报警控制器是否在100s内发出故障信号。",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":27},960831,"使任一总线回路上不少于4个火灾探测器同时处于火灾报警状态，检查区域型火灾报警控制器的负载功能。",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},960832,"热敏打印纸打印的信息经过一段时间会消失。保存时需要注意防潮、避免阳光直射，最好进行密封保存。重要的信息应采用拍照的方式进行留存。打印纸属于易耗品，无纸时应予以更换。",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":27},960833,"点型感烟火灾探测器、点型感温火灾探测器、手动报警按钮的保养项目包括：运行环境检查；设备外观检查；启动功能检查；表面清洁；接线端子检查。",[266,267],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},960834,"熔断器一般由熔体、电极及支架三部分构成。",[272,273],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},960835,"熔断器一般串联在设备进线端电源线上，由于其电阻较小，当电路正常工作时，熔断器只相当于一根导线，能够长时间、稳定地导通电流，不能够承受由于电源或外部干扰而发生的电流波动。",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},960836,"当电路中出现较大的过载电流时，熔断器熔体上产生的热量会迅速积蓄，使熔体温度上升，当温度达到熔体熔点时将熔体熔化，从两侧电极脱落，使电路断开，保护设备安全。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},960837,"使火灾探测器和手动火灾报警按钮处于报警状态，区域型火灾报警控制器应能正确显示相关报警信息。区域型火灾报警控制器自检时，各部位应正常。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},960838,"火灾报警装置启动功能测试：启动火灾警报装置，观察声、光指示正常，并且在其正前方3m水平处，使用声级计测量声信号，应满足70-120dB（A计权）。",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":25,"analysis":27},960839,"火灾报警装置的保养项目包括：运行环境检查；设备外观检查；火灾报警功能测试；启动功能检查；表面清洁；接线端子检查。",[302,303],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},960840,"标识“F2A250V”，“F”表示快速动作，“2A”表示额定电流2A，“250V”表示额定电压250V。",[308,309],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},960841,"普通熔断器因过电流熔断后不可恢复，一旦发生熔断，需选择同规格熔断器进行更换。",[314,315],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},960842,"消防应急灯具是为人员疏散、消防作业提供照明和指示标志的各类灯具，包括消防应急照明灯具和消防应急疏散标志灯具。",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,333,336,339],{"id":324,"name":325,"category":7,"favorite":326},1,"领导干部任职前廉政法规知识测试题",92,{"id":328,"name":329,"category":7,"favorite":324},595,"建筑结构与设备",{"id":331,"name":332,"category":7,"favorite":324},715,"招标采购专业知识与法律法规",{"id":334,"name":335,"category":7,"favorite":324},848,"市政方向-通用基础",{"id":337,"name":338,"category":7,"favorite":8},534,"BIM工程师",{"id":340,"name":338,"category":7,"favorite":8},535]