[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":606},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,2,50,1301,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,250,262,274,286,298,307,319,331,343,355,367,378,390,402,414,425,436,448,460,472,484,496,504,516,528,536,548,560,572,584,596],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},959777,1,"单选题","下列关于蝶阀密封性能试验说法正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","蝶阀应能承受2倍于额定工作压力的静水压，保持5min，试验时蝶阀应关闭，试验中阀门各密封处应无渗漏",true,{"key":24,"text":25,"correct":26},"B","蝶阀应能承受2倍于额定工作压力的静水压，保持3min，试验时蝶阀应关闭，试验中阀门各密封处应无渗漏",false,{"key":28,"text":29,"correct":26},"C","蝶阀应能承受4倍于额定工作压力的静水压，保持3min，试验时蝶阀应关闭，试验中阀门各密封处应无渗漏",{"key":31,"text":32,"correct":26},"D","蝶阀应能承受4倍于额定工作压力的静水压，保持5min，试验时蝶阀应关闭，试验中阀门各密封处应无渗漏","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},959778,"下列对火灾自动报警控制器故障报警信号描述错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"故障声信号应能手动消除",{"key":24,"text":41,"correct":22},"火灾自动报警系统处于手动状态，故障信号不能输入",{"key":28,"text":43,"correct":26},"故障信号再次输入时，故障声信号将再次启动",{"key":31,"text":45,"correct":26},"故障光信号应保持至故障排除",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},959779,"下列是火焰探测器误报的原因是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"探测器长期灰尘积累",{"key":24,"text":53,"correct":22},"有人电焊操作",{"key":28,"text":55,"correct":26},"环境潮湿",{"key":31,"text":57,"correct":26},"移除误报源",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},959780,"下列建筑内的部位应采用甲级防火门的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"管道井",{"key":24,"text":65,"correct":26},"消防电梯前室",{"key":28,"text":67,"correct":22},"储油间",{"key":31,"text":69,"correct":26},"电缆井",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},959781,"下列关于判断火灾报警控制器工作状态的技能操作相关说法，描述错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"当多种报警状态并存时，火灾报警控制器优先显示信息为高等级的报警状态信息",{"key":24,"text":77,"correct":26},"监控火灾报警控制器时，不能误操作火灾报警控制器的无关按键",{"key":28,"text":79,"correct":26},"当多于一个屏蔽信息时应按照时间顺序显示屏蔽部位",{"key":31,"text":81,"correct":22},"技能操作最后一步必须要填写消防设施故障维修记录表",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},959782,"下列属于控制器备电故障原因的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"备用电源电压不足",{"key":24,"text":89,"correct":26},"市电停电",{"key":28,"text":91,"correct":26},"总线与端子接触不良",{"key":31,"text":93,"correct":26},"主电熔断器熔断",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},959783,"下列组件中不属于高位消防水池的组件是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"水位计",{"key":24,"text":101,"correct":22},"消防水泵",{"key":28,"text":103,"correct":26},"溢流管",{"key":31,"text":105,"correct":26},"进水管",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},959784,"火灾自动报警控制器接收到感烟探测器报警信号，下列报警信息显示的内容不包括的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"发生的时间",{"key":24,"text":113,"correct":26},"回路号",{"key":28,"text":115,"correct":26},"设备类型",{"key":31,"text":117,"correct":22},"烟气浓度",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},959785,"火灾报警控制器的备电开关、主电开关均处于关闭或断电状态，这时火灾报警控制器处于（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"手动控制状态",{"key":24,"text":125,"correct":26},"报警状态",{"key":28,"text":127,"correct":26},"主电工作状态",{"key":31,"text":129,"correct":22},"关机状态",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},959786,"某厂房内两个防火分区分隔部位的宽度为21m时，设置防火卷帘的最大宽度是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"7m",{"key":24,"text":137,"correct":26},"8m",{"key":28,"text":139,"correct":22},"10m",{"key":31,"text":141,"correct":26},"15m",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":31,"analysis":33},959787,"为了防止发生火灾时人员被困，防火卷帘控制器应具有逃生功能，对其逃生功能的描述正确的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"卷帘降落至地面，手动操作控制器上任意一个按钮，防火卷帘应能自动开启至中位",{"key":24,"text":149,"correct":26},"拉动手动拉链，防火卷帘应能开启",{"key":28,"text":151,"correct":26},"自动开启后，延时60~120s后继续关至全闭",{"key":31,"text":153,"correct":22},"自动开启后，延时5~60s后继续关至全闭",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},959788,"火灾报警控制器的备用电源在放电至终止电压条件下充电24h，其容量应可提供火灾报警控制器在监视状态下工作（ ）h后，在相关条件下连续正常工作（ ）h。",[158,160,162,164],{"key":20,"text":159,"correct":26},"4,30",{"key":24,"text":161,"correct":26},"4,0.5",{"key":28,"text":163,"correct":26},"8,30",{"key":31,"text":165,"correct":22},"8,0.5",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},959789,"管网水流速为2m\u002Fs时，止回阀最大压力损失应不大于（ ）kPa。",[170,172,174,176],{"key":20,"text":171,"correct":26},"20",{"key":24,"text":173,"correct":26},"30",{"key":28,"text":175,"correct":22},"40",{"key":31,"text":177,"correct":26},"50",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},959790,"通过火灾报警控制器检查防火卷帘的工作状态，操作方法错误的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"查看火灾报警控制器的状态显示，确认现场防火卷帘处于故障状态",{"key":24,"text":185,"correct":26},"找到火灾报警控制器上防火卷帘的控制按钮，手动控制防火卷帘下降",{"key":28,"text":187,"correct":26},"查看防火卷帘动作反馈信号",{"key":31,"text":189,"correct":26},"操作完毕后将系统恢复至正常工作状态",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},959791,"若火灾报警控制器处于主电故障，且备用电源已经不能保证火灾报警控制器正常工作时，火灾报警控制器持续发出声故障信号并能保持（ ）h以上，声故障信号无法手动消除，则判断火灾报警控制器处于备电欠压故障状态。",[194,196,198,200],{"key":20,"text":195,"correct":22},"1",{"key":24,"text":197,"correct":26},"2",{"key":28,"text":199,"correct":26},"3",{"key":31,"text":201,"correct":26},"4",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":33},959792,"下列对防火门日常巡查内容不正确的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"门扇、门框及五金配件是否完好",{"key":24,"text":209,"correct":22},"通过监控器关闭常开防火门",{"key":28,"text":211,"correct":26},"双扇防火门是否按顺序关闭",{"key":31,"text":213,"correct":26},"闭门器是否灵活",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},959793,"下列不属于阀门的组件是（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"叶轮",{"key":24,"text":221,"correct":26},"阀座",{"key":28,"text":223,"correct":26},"驱动机构",{"key":31,"text":225,"correct":26},"阀体",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":28,"analysis":33},959794,"严寒冬季冰冻地区设置的髙位消防水箱间，应确保环境温度不低于（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":26},"0℃",{"key":24,"text":233,"correct":26},"4℃",{"key":28,"text":235,"correct":22},"5℃",{"key":31,"text":237,"correct":26},"10℃",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":20,"analysis":33},959795,"消防闸阀阀体强度试验说法正确的是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":22},"闸阀应能承受4倍于额定工作压力的静水压，保持5min，试验时闸板应全开，试验后阀体应无渗漏、变形和损坏",{"key":24,"text":245,"correct":26},"闸阀应能承受4倍于额定工作压力的静水压，保持3min，试验时闸板应全开，试验后阀体应无渗漏、变形和损坏",{"key":28,"text":247,"correct":26},"闸阀阀板处于关闭状态位置时，进水口应能承受2倍于额定工作压力的静水压，保持5min，阀门各密封处应无渗漏",{"key":31,"text":249,"correct":26},"闸阀阀板处于关闭状态位置时，进水口应能承受2倍于额定工作压力的静水压，保持3min，阀门各密封处应无渗漏",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":24,"analysis":33},959796,"火灾报警控制器自检时间超过（ ）或其不能自动停止自检功能时，火灾报警控制器的自检功能应不影响非自检部位、探测区和火灾报警控制器本身的火灾报警功能。",[254,256,258,260],{"key":20,"text":255,"correct":26},"30s",{"key":24,"text":257,"correct":22},"60s",{"key":28,"text":259,"correct":26},"90s",{"key":31,"text":261,"correct":26},"120s",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":31,"analysis":33},959797,"按充装灭火剂种类，下列不属于灭火器分类的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":26},"水基型灭火器",{"key":24,"text":269,"correct":26},"干粉型灭火器",{"key":28,"text":271,"correct":26},"二氧化碳灭火器",{"key":31,"text":273,"correct":22},"酸碱型灭火器",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":24,"analysis":33},959799,"地上建筑可配备过滤式消防自救呼吸器或化学氧自救呼吸器，高于30m的楼层内应配备防护时间不少于（ ）的自救呼吸器。",[278,280,282,284],{"key":20,"text":279,"correct":26},"15min",{"key":24,"text":281,"correct":22},"20min",{"key":28,"text":283,"correct":26},"25min",{"key":31,"text":285,"correct":26},"30min",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":20,"analysis":33},959800,"过滤装置与防护头罩间的连接能承受的轴向拉力应不小于（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":22},"50N",{"key":24,"text":293,"correct":26},"60N",{"key":28,"text":295,"correct":26},"70N",{"key":31,"text":297,"correct":26},"80N",{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":31,"analysis":33},959801,"下列不属于化学氧消防自救呼吸器按呼吸器额定防护时间分类规格的是（ ）。",[302,303,304,305],{"key":20,"text":279,"correct":26},{"key":24,"text":281,"correct":26},{"key":28,"text":285,"correct":26},{"key":31,"text":306,"correct":22},"45min",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":24,"analysis":33},959802,"下列关于化学氧消防自救呼吸器防护头罩性能要求的说法错误的是（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":26},"呼吸器在防护性能试验开始2min内贮气袋中氧体积分数应不小于17%，其余防护时间内氧体积分数应不小于21%",{"key":24,"text":314,"correct":22},"在防护时间内，贮气袋中二氧化碳体积分数应不大于1.5%，最大应不大于5.0%",{"key":28,"text":316,"correct":26},"在防护时间内，吸气温度应不高于60℃",{"key":31,"text":318,"correct":26},"在防护时间内，吸气阻力与呼气阻力之和应不大于1600Pa，且吸气或呼气的单个阻力最大应不大于1000Pa",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":20,"analysis":33},959803,"下列关于化学氧消防自救呼吸器防护头罩漏气系数说法正确的是（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"防护头罩眼区的漏气系数应不大于20%，面罩的漏气系数应不大于5%",{"key":24,"text":326,"correct":26},"防护头罩眼区的漏气系数应不大于20%，面罩的漏气系数应不大于10%",{"key":28,"text":328,"correct":26},"防护头罩眼区的漏气系数应不大于10%，面罩的漏气系数应不大于5%",{"key":31,"text":330,"correct":26},"防护头罩眼区的漏气系数应不大于10%，面罩的漏气系数应不大于10%",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":28,"analysis":33},959804,"下列关于消防水池的设置说法错误的是（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":26},"消防用水与其他用水共用的水池，应采取确保消防用水量不作他用的技术措施",{"key":24,"text":338,"correct":26},"消防水池的出水管应保证消防水池的有效容积能被全部利用",{"key":28,"text":340,"correct":22},"消防水池应设置就地水位显示装置，并应在消防控制中心或值班室等地点设置显示消防水池水位的装置，同时应有最高、正常和最低报警水位",{"key":31,"text":342,"correct":26},"消防水池应设置溢流水管和排水设施，并应采用间接排水",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":28,"analysis":33},959805,"下列关于消防水池有效容积及相关要求说法错误的是（ ）。",[347,349,351,353],{"key":20,"text":348,"correct":26},"市政给水管网能保证室外消防给水设计流量时，消防水池的有效容积应满足在火灾延续时间内室内消防用水量的要求",{"key":24,"text":350,"correct":26},"当市政给水管网不能保证室外消防给水设计流量时，消防水池的有效容积应满足火灾延续时间内室内消防用水量和室外消防用水量不足部分之和的要求",{"key":28,"text":352,"correct":22},"当消防水池采用两路消防供水且在火灾情况下连续补水能满足消防要求时，消防水池的有效容积应根据计算确定，仅设有消火栓系统时应不小于100m3",{"key":31,"text":354,"correct":26},"消防水池的总蓄水有效容积大于500m3时，宜设两格能独立使用的消防水池",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":24,"analysis":33},959806,"某建筑高度为100m的住宅建筑，设置的高位消防水箱的有效容积不应小于（ ）。",[359,361,363,365],{"key":20,"text":360,"correct":26},"36m3",{"key":24,"text":362,"correct":22},"18m3",{"key":28,"text":364,"correct":26},"50m3",{"key":31,"text":366,"correct":26},"12m3",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":31,"analysis":33},959808,"某建筑内防火分区的分隔采用防火卷帘进行分隔，分隔部位宽度为66m，下列关于防火卷帘的设置宽度说法错误的是（ ）。",[371,372,374,376],{"key":20,"text":141,"correct":26},{"key":24,"text":373,"correct":26},"18m",{"key":28,"text":375,"correct":26},"20m",{"key":31,"text":377,"correct":22},"22m",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},959809,"监控人员应釆取以防火卷帘控制器巡查为主，配合防火卷帘所在部位巡查的方法，判断防火卷帘是否处于正常工作状态，下列关于巡查和监控要求说法错误的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":26},"火灾报警控制器应能显示防火卷帘的工作状态和故障状态等动态信息",{"key":24,"text":385,"correct":26},"应能通过防火卷帘控制器关闭防火卷帘，并显示其动作反馈信号",{"key":28,"text":387,"correct":26},"关闭的防火卷帘现场手动提升复位后，防火卷帘控制器的相应反馈信号自动清除或手动复位清除",{"key":31,"text":389,"correct":22},"通过防火卷帘所在部位的巡查，确认防火卷帘下是否堆放物品，防火卷帘控制器、手动控制按钮、手动拉链等配件是否完好，通过自动操作防火卷帘等方法确认防火卷帘是否处于正常工作状态",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},959810,"下列关于疏散通道上设置的防火卷帘联动控制的说法正确的是（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":22},"所在防火分区内任意两个独立的感烟火灾探测器，由防火卷帘控制器联动控制防火卷帘下降至距地（楼）面1.8m处停止",{"key":24,"text":397,"correct":26},"所在防火分区内一个专用于联动防火卷帘的感温火灾探测器的报警信号触发联动模块，由防火卷帘控制器联动控制防火卷帘下降至距地（楼）面1.8m处停止",{"key":28,"text":399,"correct":26},"所在防烟分区内任意两个独立的感烟火灾探测器，由防火卷帘控制器联动控制防火卷帘下降至距地（楼）面1.8m处停止",{"key":31,"text":401,"correct":26},"所在防烟分区内一个专用于联动防火卷帘的感烟火灾探测器的报警信号触发联动模块，由防火卷帘控制器联动控制防火卷帘下降至距地（楼）面1.8m处停止",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":20,"analysis":33},959811,"闸阀在消防给水系统中主要用于室外埋地和室内外架空敷设的消防管道，下列关于闸阀的选用说法正确的是（ ）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"当安装室外埋地敷设的管道时，宜采用带启闭刻度的暗杆闸阀",{"key":24,"text":409,"correct":26},"设置在阀门井内时，应采用明杆闸阀",{"key":28,"text":411,"correct":26},"当安装在室外架空敷设的管道时，应采用明杆闸阀和带启闭刻度的暗杆闸阀",{"key":31,"text":413,"correct":26},"当安装在室内架空敷设的管道时，应采用耐腐蚀明杆闸阀和带启闭刻度的暗杆闸阀",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":24,"analysis":33},959812,"下列关于闸阀的密封性能试验说法正确的是（ ）。",[418,420,421,423],{"key":20,"text":419,"correct":26},"闸阀阀板处于关闭状态位置时，进水口应能承受4倍于额定工作压力的静水压，保持5min，阀门各密封处应无渗漏",{"key":24,"text":247,"correct":22},{"key":28,"text":422,"correct":26},"闸阀阀板处于关闭状态位置时，进水口应能承受2倍于额定工作压力的静水压，保持2min，阀门各密封处应无渗漏",{"key":31,"text":424,"correct":26},"闸阀阀板处于关闭状态位置时，进水口应能承受4倍于额定工作压力的静水压，保持2min，阀门各密封处应无渗漏",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":31,"analysis":33},959813,"下列关于闸阀的阀体强度试验说法正确的是（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":26},"闸阀应能承受2倍于额定工作压力的静水压，保持2min，试验时闸板应全开，试验后阀体应无渗漏、变形和损坏",{"key":24,"text":432,"correct":26},"闸阀应能承受4倍于额定工作压力的静水压，保持2min，试验时闸板应全开，试验后阀体应无渗漏、变形和损坏",{"key":28,"text":434,"correct":26},"闸阀应能承受2倍于额定工作压力的静水压，保持5min，试验时闸板应全开，试验后阀体应无渗漏、变形和损坏",{"key":31,"text":243,"correct":22},{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":24,"analysis":33},959814,"下列关于自动排气阀阀体强度试验的说法正确的是（ ）。",[440,442,444,446],{"key":20,"text":441,"correct":26},"静水压强度试验时应能承受2倍公称压力，持压时间不少于3min，无渗漏、冒汗及可见性变形",{"key":24,"text":443,"correct":22},"静水压强度试验时应能承受1.5倍公称压力，持压时间不少于3min，无渗漏、冒汗及可见性变形",{"key":28,"text":445,"correct":26},"静水压强度试验时应能承受1.5倍公称压力，持压时间不少于5min，无渗漏、冒汗及可见性变形",{"key":31,"text":447,"correct":26},"静水压强度试验时应能承受2倍公称压力，持压时间不少于5min，无渗漏、冒汗及可见性变形",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":24,"analysis":33},959815,"下列关于蝶阀密封性能试验的说法正确的是（ ）。",[452,454,456,458],{"key":20,"text":453,"correct":26},"应能承受2倍于额定工作压力的静水压，保持5min",{"key":24,"text":455,"correct":22},"应能承受4倍于额定工作压力的静水压，保持5min",{"key":28,"text":457,"correct":26},"应能承受2倍于额定工作压力的静水压，保持3min",{"key":31,"text":459,"correct":26},"应能承受4倍于额定工作压力的静水压，保持3min",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":31,"analysis":33},959816,"下列关于止回阀型号H4-1-X-100-16-Q的表示正确的是（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":26},"表示公称直径为100mm，额定工作压力不低于1.6MPa的旋启式止回阀，材质为球墨铸铁，连接方式为法兰连接，密封材料为橡胶",{"key":24,"text":467,"correct":26},"表示公称直径为100mm，额定工作压力不低于1.6MPa的升降式止回阀，材质为球墨铸铁，连接方式为卡箍连接，密封材料为橡胶",{"key":28,"text":469,"correct":26},"表示公称直径为100mm，额定工作压力不低于1.6MPa的蝶形止回阀，材质为球墨铸铁，连接方式为法兰连接，密封材料为橡胶",{"key":31,"text":471,"correct":22},"表示公称直径为100mm，额定工作压力不低于1.6MPa的升降式止回阀，材质为球墨铸铁，连接方式为法兰连接，密封材料为橡胶",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":28,"analysis":33},959817,"下列关于止回阀阀体强度试验的说法正确的是（ ）。",[476,478,480,482],{"key":20,"text":477,"correct":26},"阀体应能承受1.5倍公称压力的静水压试验，持压时间不少于5min，无渗漏、冒汗及可见性变形",{"key":24,"text":479,"correct":26},"阀体应能承受2倍公称压力的静水压试验，持压时间不少于5min，无渗漏、冒汗及可见性变形",{"key":28,"text":481,"correct":22},"阀体应能承受1.5倍公称压力的静水压试验，持压时间不少于10min，无渗漏、冒汗及可见性变形",{"key":31,"text":483,"correct":26},"阀体应能承受2倍公称压力的静水压试验，持压时间不少于10min，无渗漏、冒汗及可见性变形",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":24,"analysis":33},959818,"下列关于减压阀流量特性的说法正确的是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":26},"对直接作用式减压阀不大于出口压力的10%，对先导式减压阀不大于出口压力的5%",{"key":24,"text":491,"correct":22},"对直接作用式减压阀不大于出口压力的20%，对先导式减压阀不大于出口压力的10%",{"key":28,"text":493,"correct":26},"对直接作用式减压阀不大于出口压力的10%，对先导式减压阀不大于出口压力的20%",{"key":31,"text":495,"correct":26},"对直接作用式减压阀不大于出口压力的5%，对先导式减压阀不大于出口压力的10%",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":20,"analysis":33},959819,"下列关于减压阀压力特性的说法正确的是（ ）。",[500,501,502,503],{"key":20,"text":489,"correct":22},{"key":24,"text":491,"correct":26},{"key":28,"text":493,"correct":26},{"key":31,"text":495,"correct":26},{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":20,"analysis":33},959820,"建筑高度为32m的医疗建筑，设置的高位消防水箱的有效容积和最低有效水位应满足水灭火设施最不利点处的静水压力分别不应小于（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":22},"36m3；0.1MPa",{"key":24,"text":511,"correct":26},"18m3；0.1MPa",{"key":28,"text":513,"correct":26},"36m3；0.15MPa",{"key":31,"text":515,"correct":26},"18m3；0.07MPa",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":28,"analysis":33},959821,"某工业建筑建筑体积为20000m3，高位消防水箱的设置位置高于其所服务的水灭火设施，且最低有效水位应满足水灭火设施最不利点处的静水压力不应低于（ ）。",[520,522,524,526],{"key":20,"text":521,"correct":26},"0.05MPa",{"key":24,"text":523,"correct":26},"0.07MPa",{"key":28,"text":525,"correct":22},"0.10MPa",{"key":31,"text":527,"correct":26},"0.15MPa",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":24,"analysis":33},959822,"某建筑高度为100m的住宅建筑，高位消防水箱的设置高于其所服务的水灭火设施，且最低有效水位应满足水灭火设施最不利点处的静水压力不应低于（ ）。",[532,533,534,535],{"key":20,"text":521,"correct":26},{"key":24,"text":523,"correct":22},{"key":28,"text":525,"correct":26},{"key":31,"text":527,"correct":26},{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":24,"analysis":33},959823,"减压阀在消防给水系统中主要用于消防给水系统分区供水减压。下列条件下需要采用分区供水的是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":26},"系统工作压力为2.4MPa",{"key":24,"text":543,"correct":22},"消火栓栓口处静压为1.2MPa",{"key":28,"text":545,"correct":26},"自动水灭火系统报警阀处的工作压力为1.60MPa",{"key":31,"text":547,"correct":26},"喷头处的工作压力为1.00MPa",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":24,"analysis":33},959824,"下列不属于区域报警系统组成的是（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":26},"火灾探测器",{"key":24,"text":555,"correct":22},"消防应急广播",{"key":28,"text":557,"correct":26},"手动火灾报警按钮",{"key":31,"text":559,"correct":26},"火灾声光警报器",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":31,"analysis":33},959825,"按照国家标准《火灾报警控制器》（GB4717-2005）要求，下列关于火灾报警控制器整机一般具有的功能说法错误的是（ ）。",[564,566,568,570],{"key":20,"text":565,"correct":26},"火灾报警功能：火灾报警控制器应能直接接收来自火灾探测器及其他火灾报警触发器件的火灾报警信号，发出火灾报警声、光信号，指示火灾发生部位，记录火灾报警时间，并予以保持，直至手动复位",{"key":24,"text":567,"correct":26},"火灾报警控制功能：火灾确认后，火灾报警控制器应具有火灾声和\u002F或光报警器控制输出功能。火灾报警控制器应设置手动\u002F自动控制状态转换、手动\u002F自动控制状态指示功能",{"key":28,"text":569,"correct":26},"故障报警功能：火灾报警控制器应设故障总指示灯（器）。无论火灾报警控制器处于何种状态，只要有故障信号输入，该故障总指示灯（器）均应点亮",{"key":31,"text":571,"correct":22},"自检功能：火灾报警控制器应能自动检查其面板所有指示灯（器）、显示器的功能和所有声器件的功能",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":24,"analysis":33},959826,"下列关于区域火灾报警控制器的俄特征说法错误的是（ ）。",[576,578,580,582],{"key":20,"text":577,"correct":26},"在区域报警系统中，区域型火灾报警控制器一般设置在平时有专人值班的房间或场所",{"key":24,"text":579,"correct":22},"在集中报警系统中，消防控制室设置一台起集中控制功能的火灾报警控制器，并且可设置若干台区域型火灾报警控制器，区域型火灾报警控制器直接手动控制消防设备",{"key":28,"text":581,"correct":26},"区域型火灾报警控制器只能将信息传送给集中型火灾报警控制器及接收、处理集中型火灾报警控制器的相关指令，不能向集中型火灾报警控制器发出控制指令",{"key":31,"text":583,"correct":26},"当集中型火灾报警控制器与其相连接的区域型火灾报警控制器间连接线路发生断路、短路和影响功能的接地时，应进入故障状态并显示区域型火灾报警控制器的部位",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":28,"analysis":33},959827,"由于火灾报警控制器的备用电源（电池）存在微小的自放电电流，如果长时间不使用火灾报警控制器，需要每个月开机，对备用电源（电池）充电至少（ ）h来进行定期维护，以免损坏备用电源（电池）。",[588,590,592,594],{"key":20,"text":589,"correct":26},"12",{"key":24,"text":591,"correct":26},"24",{"key":28,"text":593,"correct":22},"48",{"key":31,"text":595,"correct":26},"96",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":24,"analysis":33},959828,"当控制器容量不超过10个报警部位时，所有报警部位均处于报警状态；火灾报警控制器的主电源容量应保证其连续正常工作（ ）h。",[600,601,602,604],{"key":20,"text":195,"correct":26},{"key":24,"text":201,"correct":22},{"key":28,"text":603,"correct":26},"5",{"key":31,"text":605,"correct":26},"8",[607,610,613,616,619,622],{"id":15,"name":608,"category":7,"favorite":609},"领导干部任职前廉政法规知识测试题",92,{"id":611,"name":612,"category":7,"favorite":15},595,"建筑结构与设备",{"id":614,"name":615,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":617,"name":618,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":620,"name":621,"category":7,"favorite":8},534,"BIM工程师",{"id":623,"name":621,"category":7,"favorite":8},535]