[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,15,50,1301,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},960542,3,"判断题","当有火灾、监管或故障等报警信号传送到火灾报警控制器时，火灾报警控制器发出相应报警信号。在准确区分火灾报警控制器的报警信号后，立即查询报警信息，确定报警部位，并尽快核实报警信息，尤其是火警信息应以最快方式进行确认。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},960543,"若确认有火灾发生，应立即拨打“119”火警电话报警，通知单位负责人，启动应急预案，开展初期火灾处置。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},960544,"如果火灾报警控制器面板操作界面上的系统故障指示灯点亮，说明该故障为系统故障，则安排专业设备检测维修人员到现场进行故障信息核实和处置，进行故障修复工作。",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},960545,"当现场部件出现误报火警时，如果有现场声光警报启动，首先应停止现场声光警报，通知现场人员及相关人员取消火警紧急状态。",[44,45],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},960546,"钮在无火情的情况下被人为按下属于手动报警按钮误报的原因。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},960547,"当发生故障报警时，首先应按火灾报警控制器的“消音”键，终止控制器故障报警声。",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},960548,"存在故障报警当场有条件维修解决的应当场维修解决；当场没有条件维修解决的，应尽可能在24h内维修解决。",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},960549,"存在故障报警需要由供应商或厂家提供零配件或协助维修解决的，若不影响系统主要功能的，应在7个工作日内解决。",[68,69],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":25,"analysis":27},960550,"光束通道被遮挡是火灾探测器故障原因。处理方法：移除遮挡物",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},960551,"当发生火灾时，向“119”火警调度指挥平台报告火警的方式有很多，应首选通过拨打火警电话“119”的方式向“119”火警调度指挥平台报告火警信息。",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},960552,"向“119”火警调度指挥平台报告火警信息后，消防值班人员应立即向所在单位的消防安全管理人报告火警信息，同时立即启动单位内部的灭火和应急疏散预案。",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":21,"analysis":27},960553,"火灾报警控制器一般设置在消防控制室或保护区域现场有人值守的场所，直接连接火灾探测器、手动火灾报警按钮和火灾声光警报器等设备。",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},960554,"当火灾报警控制器接收到第一个火灾报警信号时，发岀火灾报警声信号或故障声信号，并指示相应部位，应进入火灾报警状态；",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},960555,"如果在接收到第一个火灾报警信号后的30s内，火灾报警控制器接收到符合要求的后续火灾报警信号，则火灾报警控制器发出火灾报警声、光信号，并进入火灾报警状态；",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},960556,"无论火灾报警控制器处于何种状态，只要有屏蔽存在，该屏蔽总指示灯（器）均点亮。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},960557,"火灾报警控制器的报警信息包括火灾报警、监管报警、故障报警以及屏蔽状态等信息。",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},960558,"火灾报警控制器仅在同一个探测区内所有部位均被屏蔽的情况下，才能显示该探测区被屏蔽，否则只能显示被屏蔽部位。",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},960559,"对于当前较低等级状态的报警信号，以及复位或恢复后不再存在的报警信号，可通过火灾报警控制器运行数据存储单元的历史数据记录功能进行查询。",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":25,"analysis":27},960560,"按《火灾报警控制器》（GB4717-2005）的有关规定，火灾报警控制器断电后，其运行数据存储单元虽然自动进入保护状态，但断电前存储的数据一般仅能保存10天。",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},960561,"测器使用环境存在快速温升属于定温探测器误报的原因。",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},960562,"在对应敏感光谱波段内的干扰光源属于火焰探测器误报原因。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},960563,"当发生监管报警时，首先应按火灾报警控制器的“消音”键，终止控制器监管警报声。",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},960564,"市电停电是控制器主电故障的原因之一，处理方法是主电断电情况下，备电可以连续供电8h，应在8h内恢复供电。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},960565,"火灾是指在时间或空间上失去控制的燃烧所造成的灾害。火灾会对人身安全、社会经济和稳定、文明成果、生态环境等方面造成巨大的危害。",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},960566,"消防值班人员在接到现场火灾确认信息后，必须立即启动警报装置，同时拨打“119”火警电话向“119”火警调度指挥平台报告火警。",[170,171],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},960567,"火灾报警控制器处于正常监视状态时，其应处于备电工作，且显示器在非待机情况下应显示“系统运行正常”等类似提示信息。",[176,177],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},960568,"在听到火警声后，及时按下火灾报警控制器面板操作界面上的“消音”键，同时结合当前火灾报警控制器火警总指示灯（器）的状态和显示屏的显示信息，做出报警信号类别的正确判断。",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},960569,"火灾报警控制器是火灾自动报警系统的控制中心设备，具有接收并发出火灾报警信号并进行控制的功能，但是不能接收和发出故障信号。",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},960570,"当多于一个监管信息时，应按报警时间顺序显示所有监管信息。",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":25,"analysis":27},960571,"不论是探测器报警信号还是手动火灾报警按钮报警信号，显示器只显示火灾报警时间、部位及注释信息。",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":25,"analysis":27},960572,"在进行判断火灾报警控制器工作状态的技能操作时，只需要填写《消防设施故障维修记录表》，不需要填写《消防控制室值班记录表》。",[206,207],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":25,"analysis":27},960573,"如需操作火灾报警控制器的声和\u002F或光警报器的自检功能，可以直接到火灾报警控制器前进行操作自检。",[212,213],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},960574,"呼吸器按备用状态分为存放型和携带型两种类型。携带型省略表示，存放型用字母D表示。",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},960575,"二氧化碳灭火器瓶采用焊接气瓶，其余灭火器筒体一般采用无缝气瓶。",[224,225],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":27},960576,"推车贮压式干粉灭火器不需要压力指示器。",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},960577,"打开消防水泵出水管上试水阀，消防水泵正常启动，若能顺利出水，表示消防水泵吸水管、出水管管路通顺，各阀门均处于工作状态。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},960579,"火灾报警控制器的开机工作状态是指火灾报警控制器主电开关处于接通电源后所处的工作状态。",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},960580,"当发生主电故障时，火灾报警控制器由备电电源供电工作",[248,249],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":27},960581,"对于现场部件的检查，必须采用现场加烟等方法，检查现场部件的报警功能。",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":25,"analysis":27},960582,"火灾报警控制器应能自动检查面板所有指示灯（器）、显示器的功能。",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},960583,"检查判断火灾报警控制器电源的工作状态时，发现电源故障应及时记录并报修。",[266,267],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":25,"analysis":27},960584,"干粉型灭火器压力指示器上红色区域为工作区。",[272,273],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},960585,"闸阀采用手轮或手柄操作时其与阀轴的连接应牢固可靠，按逆时针方向转动碟板应能关闭",[278,279],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},960586,"当常闭防火门处于打开状态时，属于防火门正常状态。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},960587,"当火灾报警控制器处于某一高等级状态信息显示时，应能通过手动操作查询其他低等级状态信息，并且各状态信息不应交替显示",[290,291],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},960588,"地下建筑可配备化学氧消防自救呼吸器，地上建筑应配备化学氧消防自救呼吸器。",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":25,"analysis":27},960589,"当前高等级状态显示为火警时，应以最快方式确认，核实后立即报告消防管理人。",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},960590,"电源功能：火灾报警控制器的电源部分应具有主电源和备用电源转换装置。主电源容量和备用电源容量应能保证火灾报警控制器在不同规定条件下连续正常工作相应的时间。",[308,309],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":25,"analysis":27},960591,"区域型火灾报警控制器可以向集中型火灾报警控制器发出控制指令。",[314,315],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":25,"analysis":27},960592,"火灾报警控制器的备电开关、主电开关均处于关闭或断电状态，这时火灾报警控制器处于开机状态。",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,333,336,339],{"id":324,"name":325,"category":7,"favorite":326},1,"领导干部任职前廉政法规知识测试题",92,{"id":328,"name":329,"category":7,"favorite":324},595,"建筑结构与设备",{"id":331,"name":332,"category":7,"favorite":324},715,"招标采购专业知识与法律法规",{"id":334,"name":335,"category":7,"favorite":324},848,"市政方向-通用基础",{"id":337,"name":338,"category":7,"favorite":8},534,"BIM工程师",{"id":340,"name":338,"category":7,"favorite":8},535]