[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":730},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,13,50,1301,[13,34,46,58,70,82,100,115,130,145,159,171,186,200,215,230,245,260,275,290,304,319,333,347,361,375,389,403,417,432,446,460,475,490,501,515,529,544,558,572,586,600,615,630,645,659,673,688,702,716],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},960438,1,"单选题","下面哪种颜色不符合标志灯标志的颜色（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","绿色",false,{"key":24,"text":25,"correct":22},"B","红色",{"key":27,"text":28,"correct":22},"C","白色与绿色相结合",{"key":30,"text":31,"correct":32},"D","白色",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},960439,"支撑臂色标为蓝色表示该易熔元件洒水喷头的公称动作温度范围为（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"57~77℃",{"key":24,"text":41,"correct":22},"80~107℃",{"key":27,"text":43,"correct":32},"121~149℃",{"key":30,"text":45,"correct":22},"163~191℃",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},960440,"室内消火栓按栓阀数量可分为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"地上式和地下式",{"key":24,"text":53,"correct":22},"承插式和法兰式",{"key":27,"text":55,"correct":22},"单出口式和双出口式",{"key":30,"text":57,"correct":32},"单栓阀和双栓阀",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},960441,"推车式二氧化碳灭火器的规格不包括（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"10kg",{"key":24,"text":65,"correct":22},"20kg",{"key":27,"text":67,"correct":22},"30kg",{"key":30,"text":69,"correct":32},"40kg",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},960442,"防火阀或排烟防火阀宜具备手动关闭方式；手动操作应方便、灵活、可靠。手动关闭或开启操作力不应大于（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"50N",{"key":24,"text":77,"correct":32},"70N",{"key":27,"text":79,"correct":22},"90N",{"key":30,"text":81,"correct":22},"120N",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":99,"analysis":33},960443,2,"多选题","下列关于火灾报警信号的发出，说法正确的是（ ）。",[88,90,92,94,96],{"key":20,"text":89,"correct":32},"当有火灾探测器火灾报警信号输入时，区域型火灾报警控制器在10s内发出火灾报警声、光信号",{"key":24,"text":91,"correct":22},"当有火灾探测器火灾报警信号输入时，区域型火灾报警控制器在3s内发出火灾报警声、光信号",{"key":27,"text":93,"correct":22},"火灾报警控制器对来自火灾探测器的火灾报警信号可设置报警延时，其最大延时不超过30s，延时期间有延时光指示信号",{"key":30,"text":95,"correct":32},"火灾报警控制器对来自火灾探测器的火灾报警信号可设置报警延时，其最大延时不超过60s，延时期间有延时光指示信号",{"key":97,"text":98,"correct":32},"E","当有手动火灾报警按钮报警信号输入时，火灾报警控制器在10s内发出火灾报警声、光信号，并明确指示该报警是手动火灾报警按钮报警","ADE",{"id":101,"libraryId":5,"type":84,"typeLabel":85,"stem":102,"options":103,"answer":114,"analysis":33},960444,"在接收来自同一探测器（区）两个或两个以上火灾报警信号才确定发出火灾报警信号时，火灾报警控制器是否进入火灾报警状态的判断方法，下列说法正确的是（ ）。",[104,106,108,110,112],{"key":20,"text":105,"correct":32},"当火灾报警控制器接收到第一个火灾报警信号时，发岀火灾报警声信号或故障声信号，并指示相应部位，但不会进入火灾报警状态",{"key":24,"text":107,"correct":22},"如果在接收到第一个火灾报警信号后的30s内，火灾报警控制器接收到符合要求的后续火灾报警信号，则火灾报警控制器发出火灾报警声、光信号，并进入火灾报警状态",{"key":27,"text":109,"correct":32},"如果在接收到第一个火灾报警信号后的60s内，火灾报警控制器接收到符合要求的后续火灾报警信号，则火灾报警控制器发出火灾报警声、光信号，并进入火灾报警状态",{"key":30,"text":111,"correct":22},"如果在接收到第一个火灾报警信号后的60min内，火灾报警控制器一直未接收到符合要求的后续火灾报警信号，则第一个火灾报警信号将自动复位",{"key":97,"text":113,"correct":32},"如果在接收到第一个火灾报警信号后的30min内，火灾报警控制器一直未接收到符合要求的后续火灾报警信号，则第一个火灾报警信号将自动复位","ACE",{"id":116,"libraryId":5,"type":84,"typeLabel":85,"stem":117,"options":118,"answer":129,"analysis":33},960445,"下列属于点型感烟火灾探测器误报原因的是（ ）。",[119,121,123,125,127],{"key":20,"text":120,"correct":32},"烹饪油烟、吸烟、杀虫剂等人为原因造成",{"key":24,"text":122,"correct":32},"水蒸气、扬尘、潮湿等环境因素所致",{"key":27,"text":124,"correct":32},"探测器长期灰尘累积",{"key":30,"text":126,"correct":22},"探测器使用环境存在快速温升",{"key":97,"text":128,"correct":22},"现场环境空气洁净度不够","ABC",{"id":131,"libraryId":5,"type":84,"typeLabel":85,"stem":132,"options":133,"answer":144,"analysis":33},960446,"下列属于火灾探测器类故障原因的是（ ）。",[134,136,138,140,142],{"key":20,"text":135,"correct":32},"探测器与底座脱落，接触不良",{"key":24,"text":137,"correct":22},"重新拧紧探测器",{"key":27,"text":139,"correct":22},"主电熔断器熔断",{"key":30,"text":141,"correct":32},"总线与底座接触不良",{"key":97,"text":143,"correct":22},"电源线接触不良","AD",{"id":146,"libraryId":5,"type":84,"typeLabel":85,"stem":147,"options":148,"answer":158,"analysis":33},960447,"下列属于火灾探测器类故障处理方法的是（ ）。",[149,151,152,154,156],{"key":20,"text":150,"correct":32},"重新压接总线，与底座良好接触",{"key":24,"text":137,"correct":32},{"key":27,"text":153,"correct":32},"更换探测器。",{"key":30,"text":155,"correct":32},"清洁探测器",{"key":97,"text":157,"correct":22},"移除遮挡物","ABCD",{"id":160,"libraryId":5,"type":84,"typeLabel":85,"stem":161,"options":162,"answer":99,"analysis":33},960448,"下列属于控制器主电故障原因的是（ ）。",[163,165,167,169,170],{"key":20,"text":164,"correct":32},"市电停电",{"key":24,"text":166,"correct":22},"总线与端子接触不良",{"key":27,"text":168,"correct":22},"备用电源电压不足",{"key":30,"text":143,"correct":32},{"key":97,"text":139,"correct":32},{"id":172,"libraryId":5,"type":84,"typeLabel":85,"stem":173,"options":174,"answer":185,"analysis":33},960449,"下述设备或部位进行单独屏蔽、解除屏蔽的操作功能，火灾报警控制器应手动进行的是（ ）。",[175,177,179,181,183],{"key":20,"text":176,"correct":32},"每个部位",{"key":24,"text":178,"correct":32},"消防联动控制设备",{"key":27,"text":180,"correct":32},"故障警告设备",{"key":30,"text":182,"correct":32},"火灾报警传输设备",{"key":97,"text":184,"correct":32},"每个回路","ABCDE",{"id":187,"libraryId":5,"type":84,"typeLabel":85,"stem":188,"options":189,"answer":158,"analysis":33},960450,"下列属于报警信息报告的内容是（ ）。",[190,192,194,196,198],{"key":20,"text":191,"correct":32},"在拨通“119”火警电话后，首先确认对方是否为“119”火警受理平台，以免拨错",{"key":24,"text":193,"correct":32},"在确认对方是“119”火警调度指挥平台后，准确地报告发生火灾的建筑物所在地地址信息，包括着火单位的名称、所在区县、街道、门牌号码等详细信息",{"key":27,"text":195,"correct":32},"简述火灾发生情况。要说明起火原因、火灾范围、火势的大小、燃烧的物质、着火部位、有无受困的人员、火灾发生地点的存放物等信息",{"key":30,"text":197,"correct":32},"等待接警人员的提问，并简要、准确地回答问题",{"key":97,"text":199,"correct":22},"报警人要讲清所在单位，等待救援人员到来",{"id":201,"libraryId":5,"type":84,"typeLabel":85,"stem":202,"options":203,"answer":214,"analysis":33},960451,"火灾报警控制器电源故障状态分为（ ）。",[204,206,208,210,212],{"key":20,"text":205,"correct":32},"主电故障",{"key":24,"text":207,"correct":22},"主电欠压故障",{"key":27,"text":209,"correct":32},"备电故障",{"key":30,"text":211,"correct":32},"备电欠压故障",{"key":97,"text":213,"correct":22},"系统故障","ACD",{"id":216,"libraryId":5,"type":84,"typeLabel":85,"stem":217,"options":218,"answer":229,"analysis":33},960452,"下列属于火灾报警控制器音响器的判断方法的是（ ）。",[219,221,223,225,227],{"key":20,"text":220,"correct":32},"对于音响类器件，自检时扬声器应能依次发岀火警、监管、故障等声音，监管和故障声音应与火警声音明显区分",{"key":24,"text":222,"correct":22},"对于数码管类显示器件，应点亮所有码段，不能缺划",{"key":27,"text":224,"correct":32},"对于蜂鸣器类，应能通过频率不同来区分各种音调",{"key":30,"text":226,"correct":22},"检査打印机输出是否正常，是否存在乱码、缺纸、墨干等",{"key":97,"text":228,"correct":22},"自检时面板所有指示灯均能被点亮及熄灭，自检后指示灯恢复原状态","AC",{"id":231,"libraryId":5,"type":84,"typeLabel":85,"stem":232,"options":233,"answer":244,"analysis":33},960453,"下列信息特征中，不能判断火灾报警控制器进入监管报警状态的是（ ）。",[234,236,238,240,242],{"key":20,"text":235,"correct":22},"专用监管报警状态总指示灯点亮",{"key":24,"text":237,"correct":22},"音响器件发出警车警报声",{"key":27,"text":239,"correct":22},"显示器显示监管报警时间及部位信息",{"key":30,"text":241,"correct":32},"故障总指示灯点亮",{"key":97,"text":243,"correct":32},"显示器显示故障类型或部位信息","DE",{"id":246,"libraryId":5,"type":84,"typeLabel":85,"stem":247,"options":248,"answer":259,"analysis":33},960454,"在拨通“119”火警电话后，操作正确的是（ ）。",[249,251,253,255,257],{"key":20,"text":250,"correct":32},"首先确认对方是否为“119”火警受理平台",{"key":24,"text":252,"correct":32},"准确地报告地址信息",{"key":27,"text":254,"correct":22},"详细描述建筑平面布局",{"key":30,"text":256,"correct":32},"等待接警人员的提问",{"key":97,"text":258,"correct":32},"报警人要留下姓名电话","ABDE",{"id":261,"libraryId":5,"type":84,"typeLabel":85,"stem":262,"options":263,"answer":274,"analysis":33},960455,"某单位对火灾报警控制器历史记录查询，下列是火警历史记录信息内容的是（ ）。",[264,266,268,270,272],{"key":20,"text":265,"correct":32},"信息类型",{"key":24,"text":267,"correct":32},"发生时间",{"key":27,"text":269,"correct":32},"设备编码",{"key":30,"text":271,"correct":22},"发出的命令",{"key":97,"text":273,"correct":32},"设备类型","ABCE",{"id":276,"libraryId":5,"type":84,"typeLabel":85,"stem":277,"options":278,"answer":289,"analysis":33},960456,"下列哪些信息需要向“119”火警受理平台说明情况（ ）。",[279,281,283,285,287],{"key":20,"text":280,"correct":22},"灭火应急预案",{"key":24,"text":282,"correct":32},"起火原因",{"key":27,"text":284,"correct":32},"火灾范围",{"key":30,"text":286,"correct":32},"有无受困人员",{"key":97,"text":288,"correct":32},"燃烧的物质","BCDE",{"id":291,"libraryId":5,"type":84,"typeLabel":85,"stem":292,"options":293,"answer":289,"analysis":33},960457,"火灾报警控制器处于正常监视状态时，无（ ）等发生。",[294,296,298,300,302],{"key":20,"text":295,"correct":22},"电源接通，主电指示灯点亮",{"key":24,"text":297,"correct":32},"火灾报警",{"key":27,"text":299,"correct":32},"监管报警",{"key":30,"text":301,"correct":32},"故障报警",{"key":97,"text":303,"correct":32},"屏蔽和自检",{"id":305,"libraryId":5,"type":84,"typeLabel":85,"stem":306,"options":307,"answer":318,"analysis":33},960458,"根据《火灾自动报警系统设计规范》要求，下列动作信号可以使非疏散通道防火卷帘直接降到楼地面的是（ ）。",[308,310,312,314,316],{"key":20,"text":309,"correct":22},"防火分区内一个独立的感烟探测器和一个手动报警按钮的报警信号",{"key":24,"text":311,"correct":32},"防火分区内两个独立的感烟探测器的报警信号",{"key":27,"text":313,"correct":32},"防火分区内两个独立的感温探测器的报警信号",{"key":30,"text":315,"correct":22},"防火分区内一个独立的感温探测器和一个手动报警按钮的报警信号",{"key":97,"text":317,"correct":22},"一个专用于联动防火卷帘的感温火灾探测器报警信号","BC",{"id":320,"libraryId":5,"type":84,"typeLabel":85,"stem":321,"options":322,"answer":274,"analysis":33},960459,"下列关于灭火器外部可视零部件的功能说法正确的是（ ）。",[323,325,327,329,331],{"key":20,"text":324,"correct":32},"压力指示器是显示灭火器筒体内压力的元件",{"key":24,"text":326,"correct":32},"保险装置是防止误操作的部件",{"key":27,"text":328,"correct":32},"封记是用于识别灭火器是否被启用过的部件",{"key":30,"text":330,"correct":22},"喷嘴（或喇叭筒）是用于为灭火剂喷射流导向和改变射流状态的部件",{"key":97,"text":332,"correct":32},"当瓶体内气体压力超过设计规定时，超压安全保护装置用于释放瓶体内部气体",{"id":334,"libraryId":5,"type":84,"typeLabel":85,"stem":335,"options":336,"answer":185,"analysis":33},960461,"下列关于灭火器的配置安装说法正确的有（ ）。",[337,339,341,343,345],{"key":20,"text":338,"correct":32},"设有夹持带的挂钩、托架，夹持带的打开方式应从正面可以看到，且打开时灭火器不应掉落",{"key":24,"text":340,"correct":32},"推车式灭火器宜设置在平坦的场地上，在无外力作用下不得自行滑动",{"key":27,"text":342,"correct":32},"灭火器设置点的环境温度不得超出灭火器的使用温度范围",{"key":30,"text":344,"correct":32},"设置在室外的灭火器应釆用防湿、防寒、防晒等保护措施",{"key":97,"text":346,"correct":32},"设置在潮湿性或腐蚀性场所的灭火器应采取防湿或防锈蚀措施",{"id":348,"libraryId":5,"type":84,"typeLabel":85,"stem":349,"options":350,"answer":259,"analysis":33},960462,"下列关于手提贮压式灭火器外观检查共性内容的说法正确的是（ ）。",[351,353,355,357,359],{"key":20,"text":352,"correct":32},"灭火器标识是否完好，标识的信息是否清晰",{"key":24,"text":354,"correct":32},"提把和压把是否无变形",{"key":27,"text":356,"correct":22},"超压保护装置是否无明显损伤",{"key":30,"text":358,"correct":32},"瓶体外表是否无明显的损伤",{"key":97,"text":360,"correct":32},"喷嘴是否无堵塞、脱落、连接松动和损伤等现象",{"id":362,"libraryId":5,"type":84,"typeLabel":85,"stem":363,"options":364,"answer":114,"analysis":33},960463,"下列关于化学氧消防自救呼吸器相关技术性能要求的说法正确的有（ ）。",[365,367,369,371,373],{"key":20,"text":366,"correct":32},"化学氧消防自救呼吸器的所有金属零部件应经过耐腐蚀处理，其表面应无龟裂、皱折、毛刺等缺陷",{"key":24,"text":368,"correct":22},"呼吸器的佩戴质量应不大于1000g",{"key":27,"text":370,"correct":32},"呼吸器对于规定的机械负荷、环境温度和湿度变化应具有足够的稳定性，不应有裂纹、爆开、破碎等导致失效的损坏",{"key":30,"text":372,"correct":22},"防护头罩眼区的漏气系数应不大于5%，面罩的漏气系数应不大于20%",{"key":97,"text":374,"correct":32},"防护头罩的总视野应不小于70%，双目视野应不小于55%，下方视野应不小于35%",{"id":376,"libraryId":5,"type":84,"typeLabel":85,"stem":377,"options":378,"answer":185,"analysis":33},960464,"监控人员应采取以防火门监控器、火灾报警控制器监控为主，配合防火门所在部位的巡查方法，判断防火门是否处于正常工作状态，下列关于防火门巡查和监控要求说法正确的是（ ）。",[379,381,383,385,387],{"key":20,"text":380,"correct":32},"火灾报警控制器应能显示防火门的工作状态和故障状态等动态信息",{"key":24,"text":382,"correct":32},"防火门监控器应能显示与其连接的防火门的地址、工作状态和故障状态等动态信息，以及人员密集场所中因管理需要平时常闭的疏散门的工作状态",{"key":27,"text":384,"correct":32},"操作人员应能通过防火门监控器关闭常开防火门，并显示防火门的动作反馈信号",{"key":30,"text":386,"correct":32},"防火门现场复位后，防火门监控器上的反馈信号可自动清除或手动复位清除，火灾报警控制器复位至正常监视状态",{"key":97,"text":388,"correct":32},"防火门所在部位的巡查主要包括：门前是否堆放物品；门扇、门框及五金配件是否完好；常闭门关闭是否严密；闭门器是否灵活；手动操作释放器查看常开门关闭是否严密；双扇防火门是否按顺序关闭等",{"id":390,"libraryId":5,"type":84,"typeLabel":85,"stem":391,"options":392,"answer":274,"analysis":33},960465,"防火卷帘控制器是控制防火卷帘升降的重要电控设备，下列关于其功能特点说法正确的是（ ）。",[393,395,397,399,401],{"key":20,"text":394,"correct":32},"防火卷帘控制器可通过配接的手动按钮手动控制防火卷帘的升降",{"key":24,"text":396,"correct":32},"防火卷帘控制器也可通过接收火灾探测器组发出的火灾报警信号控制防火卷帘的下降",{"key":27,"text":398,"correct":32},"防火卷帘控制器还可通过接收消防控制中心的火灾报警控制器或消防联动控制设备发出的联动触发信号控制防火卷帘的下降，实现联动控制",{"key":30,"text":400,"correct":22},"当火灾发生时，若卷帘处在中位下，手动操作控制器上任意一个按钮，防火卷帘应能自动开启至中位，延时5～90s后继续关至全闭",{"key":97,"text":402,"correct":32},"防火卷帘控制器设有电源相序保护装置，当电源缺相或相序有误时，能保护卷帘不发生反转",{"id":404,"libraryId":5,"type":84,"typeLabel":85,"stem":405,"options":406,"answer":129,"analysis":33},960466,"闸阀在消防给水系统中主要用于室外埋地和室内外架空敷设的消防管道。下列关于闸阀的选用说法正确的是（ ）。",[407,409,411,413,415],{"key":20,"text":408,"correct":32},"当安装在室外埋地敷设的管道时，宜采用带启闭刻度的暗杆闸阀",{"key":24,"text":410,"correct":32},"当设置在阀门井内时，应采用耐腐蚀的明杆闸阀",{"key":27,"text":412,"correct":32},"当安装在室外架空敷设的管道时，应采用耐腐蚀明杆闸阀和带启闭刻度的暗杆闸阀",{"key":30,"text":414,"correct":22},"消防水泵吸水管宜采用明杆闸阀",{"key":97,"text":416,"correct":22},"消防水泵的出水管应采用明杆闸阀或带启闭刻度和标志的暗杆闸阀",{"id":418,"libraryId":5,"type":84,"typeLabel":85,"stem":419,"options":420,"answer":431,"analysis":33},960467,"下列关于闸阀的基本性能说法正确的是（ ）。",[421,423,425,427,429],{"key":20,"text":422,"correct":32},"密封性能：闸阀阀板处于关闭状态位置时，进水口应能承受2倍于额定工作压力的静水压，保持5min，阀门各密封处应无渗漏",{"key":24,"text":424,"correct":32},"阀体强度：闸阀应能承受4倍于额定工作压力的静水压，保持5min，试验时闸板应全开，试验后阀体应无渗漏、变形和损坏",{"key":27,"text":426,"correct":22},"手轮应采用锁紧螺母固定在阀杆上，其外缘直径不大于规定值",{"key":30,"text":428,"correct":32},"大操作扭矩：开启或关闭的输入扭矩不超过规定值",{"key":97,"text":430,"correct":22},"釆用电动、气动或液压等方式驱动，其驱动装置应保证阀门在进、出口最大压差不小于其额定工作压力下能正常动作","ABD",{"id":433,"libraryId":5,"type":84,"typeLabel":85,"stem":434,"options":435,"answer":99,"analysis":33},960468,"下列关于减压阀的基本性能说法正确的是（ ）。",[436,438,440,442,444],{"key":20,"text":437,"correct":32},"在给定的调压范围内，出口压力能在最大值与最小值之间连续调整，不得有卡阻和异常振动",{"key":24,"text":439,"correct":22},"流量特性：对直接作用式减压阀不大于出口压力的10%，对先导式减压阀不大于出口压力的50%",{"key":27,"text":441,"correct":22},"压力特性：对直接作用式减压阀不大于岀口压力的20%，对先导式减压阀不大于出口压力的10%",{"key":30,"text":443,"correct":32},"密封性能：当DN≤50mm，最大渗漏量不大于5滴（气泡）\u002Fmin",{"key":97,"text":445,"correct":32},"密封性能：当DN≥150mm，最大渗漏量不大于20滴（气泡）\u002Fmin。对于金属密封结构，允许渗漏量不大于最大流量的0.5%",{"id":447,"libraryId":5,"type":84,"typeLabel":85,"stem":448,"options":449,"answer":459,"analysis":33},960469,"下列关于过滤式消防自救呼吸器相关技术性能要求的说法正确的有（ ）。",[450,452,453,455,457],{"key":20,"text":451,"correct":22},"呼吸器佩戴质量不应大于1800g",{"key":24,"text":370,"correct":32},{"key":27,"text":454,"correct":32},"在额定防护时间内，任何单个5min内，一氧化碳透过浓度的时间加权平均值应不大于200mL\u002Fm3，吸气温度应不高于65℃，吸气阻力应不大于800Pa，呼气阻力应不大于300Pa",{"key":30,"text":456,"correct":32},"过滤装置与防护头罩间的连接能承受的轴向拉力应不小于50N",{"key":97,"text":458,"correct":22},"若呼吸器中不设半面罩，则防护头罩的漏气系数应不大于20%","BCD",{"id":461,"libraryId":5,"type":84,"typeLabel":85,"stem":462,"options":463,"answer":474,"analysis":33},960470,"下列关于自动排气阀的基本性能说法正确的是（ ）。",[464,466,468,470,472],{"key":20,"text":465,"correct":22},"阀体强度：静水压强度试验时应能承受1.1倍公称压力，持压时间不少于3min，无渗漏、冒汗及可见性变形",{"key":24,"text":467,"correct":22},"浮球强度：用等于1.6MPa的浮球应能承受大于或等于3.2MPa的静水压，持压24h，无可见性变形，无向内渗漏增重现象",{"key":27,"text":469,"correct":32},"小排气孔尺寸应大于等于φ1.6mm",{"key":30,"text":471,"correct":32},"空气关闭压力：进排气阀大量排气，浮球被吹起而闭阀时，阀的进、出瞬时排气压差△p应大于或等于0.1MPa",{"key":97,"text":473,"correct":22},"当管道内出现负压时，进排气阀应快速向管道进气。进气量按排气量的85%选取","CD",{"id":476,"libraryId":5,"type":84,"typeLabel":85,"stem":477,"options":478,"answer":489,"analysis":33},960471,"下列关于蝶阀的基本性能说法正确的是（ ）。",[479,481,483,485,487],{"key":20,"text":480,"correct":22},"机械强度：在阀门手轮和手柄上施加990N的力，应无损坏",{"key":24,"text":482,"correct":22},"水力摩阻：阀门在通流流速4.5m\u002Fs的条件下，因水力摩阻产生的压力损失不应超过0.01MPa",{"key":27,"text":484,"correct":32},"工作循环：阀门进、出口压差在额定工作压力下，经5000次正常工作循环应开启灵活、无损坏",{"key":30,"text":486,"correct":32},"强度要求：阀门应能承受4倍于额定工作压力的静水压，保持5min，试验时蝶阀应全开，试验中蝶阀应无渗漏、变形和损坏",{"key":97,"text":488,"correct":32},"密封性能：蝶阀应能承受2倍于额定工作压力的静水压，保持5min，试验时应关闭，试验中阀门各密封处应无渗漏","CDE",{"id":491,"libraryId":5,"type":84,"typeLabel":85,"stem":492,"options":493,"answer":214,"analysis":33},960472,"下列关于推车贮压式灭火器外观检查共性内容的说法正确的是（ ）。",[494,495,496,498,499],{"key":20,"text":352,"correct":32},{"key":24,"text":354,"correct":22},{"key":27,"text":497,"correct":32},"阀门操作机构是否无损坏",{"key":30,"text":358,"correct":32},{"key":97,"text":500,"correct":22},"压力指示器是否指示在绿区范围内",{"id":502,"libraryId":5,"type":84,"typeLabel":85,"stem":503,"options":504,"answer":185,"analysis":33},960473,"下列关于灭火器的安装检查内容的说法正确的是（ ）。",[505,507,509,511,513],{"key":20,"text":506,"correct":32},"灭火器是否被放置在指定的位置",{"key":24,"text":508,"correct":32},"灭火器周围是否不存在有障碍物、遮挡、拴系等影响取用的现象",{"key":27,"text":510,"correct":32},"灭火器箱的箱门是否开启灵活，无零部件损坏，箱内干燥、清洁，取拿灭火器方便",{"key":30,"text":512,"correct":32},"灭火器放置场所是否有防雨、防晒等保护措施，是否符合灭火器的使用温度",{"key":97,"text":514,"correct":32},"灭火器类型、灭火级别和数量是否符合配置要求",{"id":516,"libraryId":5,"type":84,"typeLabel":85,"stem":517,"options":518,"answer":99,"analysis":33},960474,"下列关于过滤式消防自救呼吸器的说法正确的有（ ）。",[519,521,523,525,527],{"key":20,"text":520,"correct":32},"“TZL30”表示额定防护时间为30min的存放型过滤式消防自救呼吸器",{"key":24,"text":522,"correct":22},"过滤式消防自救呼吸类逃生避难器材适用于人员密集的公共建筑的地上楼层和地下公共建筑",{"key":27,"text":524,"correct":22},"地上建筑可配备过滤式消防自救呼吸器或化学氧自救呼吸器，高于50m的楼层内应配备防护时间不少于20min的自救呼吸器",{"key":30,"text":526,"correct":32},"地下建筑应配备化学氧消防自救呼吸器",{"key":97,"text":528,"correct":32},"按照1具\u002F人要求配备",{"id":530,"libraryId":5,"type":84,"typeLabel":85,"stem":531,"options":532,"answer":543,"analysis":33},960475,"根据《消防给水及消火栓系统技术规范》（GB50974-2014）规定，下列关于高位消防水箱的设置位置应高于其所服务的水灭火设施，且最低有效水位应满足水灭火设施最不利点处的静水压力，说法不符合规范规定的是（ ）。",[533,535,537,539,541],{"key":20,"text":534,"correct":22},"建筑高度为30m的医院门诊楼，最低有效水位应满足水灭火设施最不利点处的静水压力不应低于0.10MPa",{"key":24,"text":536,"correct":32},"建筑高度为168m的住宅楼，最低有效水位应满足水灭火设施最不利点处的静水压力不应低于0.15MPa",{"key":27,"text":538,"correct":32},"建筑高度为30m的办公楼，最低有效水位应满足水灭火设施最不利点处的静水压力不应低于0.10MPa",{"key":30,"text":540,"correct":22},"建筑高度为27m的住宅建筑，最低有效水位应满足水灭火设施最不利点处的静水压力不宜低于0.07MPa",{"key":97,"text":542,"correct":32},"某工业建筑体积为20000m3，最低有效水位应满足水灭火设施最不利点处的静水压力不应低于0.07MPa","BCE",{"id":545,"libraryId":5,"type":84,"typeLabel":85,"stem":546,"options":547,"answer":259,"analysis":33},960476,"下列关于消防水池设置要求说法正确的是（ ）。",[548,550,552,554,556],{"key":20,"text":549,"correct":32},"对于消防用水与其他用水共用的水池，应采取确保消防用水量不作他用的技术措施",{"key":24,"text":551,"correct":32},"消防水池的出水管应保证消防水池的有效容积能被全部利用",{"key":27,"text":553,"correct":22},"消防水池应设置就地水位显示装置，并应在消防控制中心或值班室等地点设置显示消防水池水位的装置，同时应有正常、最高和最低报警水位",{"key":30,"text":555,"correct":32},"消防水池应设置溢流水管和排水设施，并应采用间接排水",{"key":97,"text":557,"correct":32},"消防水池通气管、呼吸管和溢流水管等应采取防止虫鼠等进入消防水池的技术措施",{"id":559,"libraryId":5,"type":84,"typeLabel":85,"stem":560,"options":561,"answer":489,"analysis":33},960477,"下列关于防火门的设置说法错误的是（ ）。",[562,564,566,568,570],{"key":20,"text":563,"correct":22},"防火门通常用在防火墙、防火隔墙和管井竖壁上，除允许设置常开防火门的位置外，其他位置的防火门均应采用常闭防火门",{"key":24,"text":565,"correct":22},"疏散通道上的防火门应向疏散方向开启，并在关闭后应能从任意侧手动开启",{"key":27,"text":567,"correct":32},"建筑内防烟楼梯间和通向前室的门应采用甲级防火门",{"key":30,"text":569,"correct":32},"为防止烟火通过变形缝蔓延，设在变形缝附近的防火门应安装在楼层较多的一侧，门扇开启后可跨越变形缝",{"key":97,"text":571,"correct":32},"建筑内管道井、电缆井等竖向井道的检查门应采用乙级防火门",{"id":573,"libraryId":5,"type":84,"typeLabel":85,"stem":574,"options":575,"answer":259,"analysis":33},960478,"下列关于防火门的控制与操作说法正确的是（ ）。",[576,578,580,582,584],{"key":20,"text":577,"correct":32},"手动控制操作可直接在火灾报警控制器、防火门监控器上通过总线手动控制防火门的关闭，控制器应显示防火门动作反馈信号",{"key":24,"text":579,"correct":32},"手动控制操作可在常开防火门所在部位手动操作释放器关闭防火门",{"key":27,"text":581,"correct":22},"分别触发常开防火门所在防烟分区内两个独立的火灾探测器，火灾报警控制器或防火门监控器发出自动关闭防火门的触发信号，并将防火门关闭的动作信号反馈至监控设备上",{"key":30,"text":583,"correct":32},"分别触发常开防火门所在防烟分区内一个火灾探测器与一个手动火灾报警按钮，火灾报警控制器或防火门监控器发出自动关闭防火门的触发信号，并将防火门关闭的动作信号反馈至监控设备上",{"key":97,"text":585,"correct":32},"需现场人工拉动防火门进行复位，复位后防火门状态信息也将同时反馈至火灾报警控制器或防火门监控器",{"id":587,"libraryId":5,"type":84,"typeLabel":85,"stem":588,"options":589,"answer":431,"analysis":33},960479,"下列关于消防给水阀门的安装要求说法正确的是（ ）。",[590,592,594,596,598],{"key":20,"text":591,"correct":32},"阀门的设置应便于安装、维修和操作，且安装空间应能满足阀门完全启闭的要求，并应做出标志",{"key":24,"text":593,"correct":32},"消防给水系统干管与水灭火系统连接处应设置独立阀门，并应保证各系统独立使用",{"key":27,"text":595,"correct":22},"减压阀安装应在供水管网试压、冲洗前进行",{"key":30,"text":597,"correct":32},"减压阀前有过滤器或自带过滤器",{"key":97,"text":599,"correct":22},"减压阀前应安装压力表或自带压力表",{"id":601,"libraryId":5,"type":84,"typeLabel":85,"stem":602,"options":603,"answer":614,"analysis":33},960480,"下列关于消防给水阀门的维护管理说法错误的是（ ）。",[604,606,608,610,612],{"key":20,"text":605,"correct":22},"每月应对铅封、锁链进行一次检查",{"key":24,"text":607,"correct":32},"每月应对室外阀门井中进水管上的控制阀门进行一次检查",{"key":27,"text":609,"correct":22},"每天对水源控制阀进行外观检查",{"key":30,"text":611,"correct":32},"每季度对减压阀组进行一次放水试验",{"key":97,"text":613,"correct":22},"每年应对减压阀的流量和压力进行一次试验","BD",{"id":616,"libraryId":5,"type":84,"typeLabel":85,"stem":617,"options":618,"answer":629,"analysis":33},960481,"下列场所不宜选用感烟探测器的是（ ）。",[619,621,623,625,627],{"key":20,"text":620,"correct":32},"有大量水汽滞留的场所",{"key":24,"text":622,"correct":32},"可能产生腐蚀性气体的场所",{"key":27,"text":624,"correct":22},"气流速度为3m\u002Fs的场所",{"key":30,"text":626,"correct":22},"相对湿度经常为85%的场所",{"key":97,"text":628,"correct":32},"在正常情况下有烟滞留的场所","ABE",{"id":631,"libraryId":5,"type":84,"typeLabel":85,"stem":632,"options":633,"answer":644,"analysis":33},960482,"下列属于室内消防给水系统按照系统服务范围分类的是（ ）。",[634,636,638,640,642],{"key":20,"text":635,"correct":32},"独立的高压（临时高压）消防给水系统",{"key":24,"text":637,"correct":32},"区域集中的高压（临时高压）消防给水系统",{"key":27,"text":639,"correct":22},"生产、生活、消防合用给水系统",{"key":30,"text":641,"correct":22},"生产、消防合用给水系统",{"key":97,"text":643,"correct":22},"独立的消防给水系统","AB",{"id":646,"libraryId":5,"type":84,"typeLabel":85,"stem":647,"options":648,"answer":474,"analysis":33},960483,"下列不属于按消火栓箱安装方式不同分类的是（ ）。",[649,651,653,655,657],{"key":20,"text":650,"correct":22},"明装式消火栓箱",{"key":24,"text":652,"correct":22},"暗装式消火栓箱",{"key":27,"text":654,"correct":32},"挂置式消火栓箱",{"key":30,"text":656,"correct":32},"卷盘式消火栓箱",{"key":97,"text":658,"correct":22},"半暗装式消火栓箱",{"id":660,"libraryId":5,"type":84,"typeLabel":85,"stem":661,"options":662,"answer":289,"analysis":33},960484,"下列属于消防水枪按喷射的灭火水流形式分类的是（ ）。",[663,665,667,669,671],{"key":20,"text":664,"correct":22},"开花水枪",{"key":24,"text":666,"correct":32},"直流开花水枪",{"key":27,"text":668,"correct":32},"喷雾水枪",{"key":30,"text":670,"correct":32},"直流喷雾水枪",{"key":97,"text":672,"correct":32},"多功能水枪",{"id":674,"libraryId":5,"type":84,"typeLabel":85,"stem":675,"options":676,"answer":687,"analysis":33},960485,"下列按消防水枪的供水压力分类的是（ ）。",[677,679,681,683,685],{"key":20,"text":678,"correct":22},"低压水枪（1.6MPa≥p＞0.1MPa）",{"key":24,"text":680,"correct":32},"中压水枪（2.5MPa≥p＞1.6MPa）",{"key":27,"text":682,"correct":22},"中压水枪（3.0MPa≥p＞1.6MPa）",{"key":30,"text":684,"correct":22},"高压水枪（4.0MPa≥p＞3.0MPa）",{"key":97,"text":686,"correct":32},"超高压水枪（p＞4.0MPa）","BE",{"id":689,"libraryId":5,"type":84,"typeLabel":85,"stem":690,"options":691,"answer":474,"analysis":33},960487,"下列关于轻便消防水龙的基本性能说法正确的是（ ）。",[692,694,696,698,700],{"key":20,"text":693,"correct":22},"轻便消防水龙在大于设计压力的1.5倍工作压力下喷射，其流量、射程满足要求",{"key":24,"text":695,"correct":22},"轻便消防水龙灌满水排净空气后关闭喷枪，缓慢升至设计工作压力，保压5min，检查水龙各密封部位，应无渗漏、变形和脱落现象",{"key":27,"text":697,"correct":32},"在1.5倍设计工作压力下，轻便消防水龙应无渗漏现象；在3倍设计工作压力下，不应爆破和泄漏",{"key":30,"text":699,"correct":32},"轻便消防水龙的水带单位长度质量应不超过180g\u002Fm",{"key":97,"text":701,"correct":22},"设计工作压力下轻便消防水龙的轴向延伸率和直径的膨胀率应不大于3%",{"id":703,"libraryId":5,"type":84,"typeLabel":85,"stem":704,"options":705,"answer":244,"analysis":33},960488,"下列关于物质的分类说法不正确的是（ ）。",[706,708,710,712,714],{"key":20,"text":707,"correct":22},"A类火灾：涉及可燃固体物质的火灾",{"key":24,"text":709,"correct":22},"B类火灾：涉及易燃或可燃液体或可融化的固体物质的火灾",{"key":27,"text":711,"correct":22},"C类火灾：涉及可燃气体的火灾",{"key":30,"text":713,"correct":32},"D类火灾（带电火灾）：物质带电燃烧的火灾",{"key":97,"text":715,"correct":32},"F类火灾：涉及可燃金属的火灾",{"id":717,"libraryId":5,"type":84,"typeLabel":85,"stem":718,"options":719,"answer":158,"analysis":33},960489,"下列属于二氧化碳灭火器操作注意事项的是（ ）。",[720,722,724,726,728],{"key":20,"text":721,"correct":32},"不宜在室外有大风或室内有强烈空气对流处使用",{"key":24,"text":723,"correct":32},"在狭小的密闭空间使用后，使用者应迅速撤离",{"key":27,"text":725,"correct":32},"使用时应注意，不能用裸手直接握住喇叭筒",{"key":30,"text":727,"correct":32},"二氧化碳灭火剂喷射时会产生干冰，使用时应考虑其会产生的冷凝效应",{"key":97,"text":729,"correct":22},"二氧化碳灭火器的抗复燃性好",[731,734,737,740,743,746],{"id":15,"name":732,"category":7,"favorite":733},"领导干部任职前廉政法规知识测试题",92,{"id":735,"name":736,"category":7,"favorite":15},595,"建筑结构与设备",{"id":738,"name":739,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":741,"name":742,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":744,"name":745,"category":7,"favorite":8},534,"BIM工程师",{"id":747,"name":745,"category":7,"favorite":8},535]