[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":582},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,10,50,1301,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,223,231,243,255,267,276,288,300,312,324,332,344,356,368,380,392,403,414,426,438,450,462,471,481,489,497,507,519,527,536,546,558,570],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},960245,1,"单选题","消防控制室内，控制盘前操作距离，双列布置时不应小于（ ）m。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1",false,{"key":24,"text":25,"correct":26},"B","2",true,{"key":28,"text":29,"correct":22},"C","3",{"key":31,"text":32,"correct":22},"D","5","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},960246,"当火灾报警控制器检测到外接受控消防设备的（ ）信号时，反馈灯点亮，反馈信号消失或控制器进行复位操作后，此灯熄灭。",[38,40,42,44],{"key":20,"text":39,"correct":26},"反馈",{"key":24,"text":41,"correct":22},"启动",{"key":28,"text":43,"correct":22},"火警",{"key":31,"text":45,"correct":22},"故障",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},960248,"《消防控制室值班记录表》是消防控制室（ ）用于日常值班时记录火灾报警控制器运行情况及日检查情况的。",[50,52,54,56],{"key":20,"text":51,"correct":22},"消防安全管理人",{"key":24,"text":53,"correct":26},"消防值班人员",{"key":28,"text":55,"correct":22},"保安员",{"key":31,"text":57,"correct":22},"消防巡查人员",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},960251,"火灾自动报警系统中用于发出声光警报信号，疏散火灾现场人员的设备是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"感烟探测器",{"key":24,"text":65,"correct":22},"手动报警按钮",{"key":28,"text":67,"correct":26},"声光警报器",{"key":31,"text":69,"correct":22},"消火栓按钮",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},960253,"误报排除后应经单位消防安全管理人检查确认，维修情况应记入（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"《建筑消防设施故障维修记录表》",{"key":24,"text":77,"correct":22},"《消防值班记录表》",{"key":28,"text":79,"correct":22},"《消防巡查记录表》",{"key":31,"text":81,"correct":22},"《消防月度检查记录表》",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},960255,"消防控制室根据建筑物的实际情况，可独立设置，也可以与消防值班室、保安监控室、综合控制室等合用，并保证专人（ ）值班。",[86,88,90,92],{"key":20,"text":87,"correct":22},"8h",{"key":24,"text":89,"correct":22},"12h",{"key":28,"text":91,"correct":22},"18h",{"key":31,"text":93,"correct":26},"24h",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},960256,"消防电话系统是一种（ ）专用的通讯系统，通过这个系统可迅速实现对火灾的人工确认。",[98,100,102,104],{"key":20,"text":99,"correct":22},"工业",{"key":24,"text":101,"correct":22},"商场",{"key":28,"text":103,"correct":22},"安防",{"key":31,"text":105,"correct":26},"消防",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},960257,"设有火灾自动报警系统和自动灭火系统或设有火灾自动报警系统和机械防（排）烟设施的建筑，应设置（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"公安消防队",{"key":24,"text":113,"correct":22},"消防值班室",{"key":28,"text":115,"correct":22},"消防巡逻室",{"key":31,"text":117,"correct":26},"消防控制室",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},960258,"多线制消防电话系统由设置在消防控制中心的（ ）、火灾报警控制器和现场的消防电话插孔及消防电话分机构成。",[122,124,126,128],{"key":20,"text":123,"correct":22},"总线制消防电活总机",{"key":24,"text":125,"correct":26},"多线制消防电话总机",{"key":28,"text":127,"correct":22},"消防联动控制器",{"key":31,"text":129,"correct":22},"模块",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},960259,"在平时，消防控制室全天候地监控各种（ ）的工作状态，保持系统的正常运行。",[134,136,138,140],{"key":20,"text":135,"correct":22},"安防设备",{"key":24,"text":137,"correct":22},"通信设备",{"key":28,"text":139,"correct":26},"消防设备",{"key":31,"text":141,"correct":22},"检测设备",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},960260,"火灾报警控制器按应用方式分类下列叙述不正确的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":26},"船用型",{"key":24,"text":149,"correct":22},"区域型",{"key":28,"text":151,"correct":22},"集中型",{"key":31,"text":153,"correct":22},"集中区域兼容型",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":31,"analysis":33},960261,"信息显示与查询功能控制器信息显示按（ ）及其他状态顺序由高至低排列信息显示等级。",[158,160,162,164],{"key":20,"text":159,"correct":22},"故障报警、屏蔽",{"key":24,"text":161,"correct":22},"故障报警、监管报警",{"key":28,"text":163,"correct":22},"报警、控制、启动",{"key":31,"text":165,"correct":26},"火灾报警、监管报警",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},960262,"下列不属于控制器内部故障的现象有（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"主电故障",{"key":24,"text":173,"correct":26},"模块故障",{"key":28,"text":175,"correct":22},"总线故障",{"key":31,"text":177,"correct":22},"备电故障",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":31,"analysis":33},960263,"现场设备故障应及时维修，若因特殊原因不能及时排除的故障，也可先将其（ ），待故障排除后再将其恢复。",[182,184,186,188],{"key":20,"text":183,"correct":22},"复位",{"key":24,"text":185,"correct":22},"消音",{"key":28,"text":187,"correct":22},"摘除",{"key":31,"text":189,"correct":26},"屏蔽",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":24,"analysis":33},960264,"当报备电故障时，应检查备用电池的连接器及接线；当备用电池连续工作时间超过8小时后，也可能因（ ）而报备电故障。",[194,196,198,200],{"key":20,"text":195,"correct":22},"电压过高",{"key":24,"text":197,"correct":26},"电压过低",{"key":28,"text":199,"correct":22},"电流过高",{"key":31,"text":201,"correct":22},"电流过低",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},960265,"消防控制室应设有一部用于火灾报警的（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":26},"外线电话",{"key":24,"text":209,"correct":22},"内线电话",{"key":28,"text":211,"correct":22},"投币电话",{"key":31,"text":213,"correct":22},"手机",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},960266,"火灾自动报警系统中用于探测火灾的设备是（ ）。",[218,220,221,222],{"key":20,"text":219,"correct":26},"火灾探测器",{"key":24,"text":65,"correct":22},{"key":28,"text":67,"correct":22},{"key":31,"text":69,"correct":22},{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":28,"analysis":33},960267,"消防控制室内，在值班人员经常工作的一面，控制盘至墙的距离不应小于（ ）m。",[227,228,229,230],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":26},{"key":31,"text":32,"correct":22},{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":31,"analysis":33},960268,"在使用过备电供电后，需要尽快恢复主电供电并给电池充电（ ）h，以防蓄电池损坏。",[235,237,239,241],{"key":20,"text":236,"correct":22},"24",{"key":24,"text":238,"correct":22},"32",{"key":28,"text":240,"correct":22},"40",{"key":31,"text":242,"correct":26},"48",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":31,"analysis":33},960269,"消防控制室值班人员接到报警信号后，应迅速到达报警点确认。如未发生火情，应查明（ ），采取相应措施，并认真做好记录。",[247,249,251,253],{"key":20,"text":248,"correct":22},"故障原因",{"key":24,"text":250,"correct":22},"周围情况",{"key":28,"text":252,"correct":22},"报警人员",{"key":31,"text":254,"correct":26},"报警原因",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":28,"analysis":33},960270,"下列不属于造成探测器误报警的因素是（ ）。",[259,261,263,265],{"key":20,"text":260,"correct":22},"油烟",{"key":24,"text":262,"correct":22},"灰尘",{"key":28,"text":264,"correct":26},"噪声",{"key":31,"text":266,"correct":22},"潮湿",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":28,"analysis":33},960271,"具有接收各区域型控制器传递信息的火灾报警控制器是（ ）火灾报警控制器。",[271,273,274,275],{"key":20,"text":272,"correct":22},"独立型",{"key":24,"text":149,"correct":22},{"key":28,"text":151,"correct":26},{"key":31,"text":153,"correct":22},{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":20,"analysis":33},960272,"火灾自动报警系统的主电源应采用（ ）。",[280,282,284,286],{"key":20,"text":281,"correct":26},"消防电源",{"key":24,"text":283,"correct":22},"动力电源",{"key":28,"text":285,"correct":22},"照明电源",{"key":31,"text":287,"correct":22},"直流电源",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":20,"analysis":33},960273,"处置误报火警的方法，下列叙述不正确的是（ ）。",[292,294,296,298],{"key":20,"text":293,"correct":26},"拨打119",{"key":24,"text":295,"correct":22},"通知中控室",{"key":28,"text":297,"correct":22},"恢复系统正常",{"key":31,"text":299,"correct":22},"记录误报的时间、部位、原因",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":31,"analysis":33},960275,"关于交接班注意事项叙述不正确的是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":22},"交接记录有无遗漏",{"key":24,"text":307,"correct":22},"仔细核查各系统的工作状态是否正常，有无不正常发生",{"key":28,"text":309,"correct":22},"仔细核查各系统的关键部位有无故障和失效情况",{"key":31,"text":311,"correct":26},"若存在不确定的情况，不可交接",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":24,"analysis":33},960276,"消防控制室的送、回风管在其穿墙处应设（ ）。",[316,318,320,322],{"key":20,"text":317,"correct":22},"排烟阀",{"key":24,"text":319,"correct":26},"防火阀",{"key":28,"text":321,"correct":22},"百叶窗",{"key":31,"text":323,"correct":22},"挡烟垂壁",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":31,"analysis":33},960280,"火灾自动报警系统中用于通知消防控制中心现场需要消火栓灭火的设备是（ ）。",[328,329,330,331],{"key":20,"text":63,"correct":22},{"key":24,"text":65,"correct":22},{"key":28,"text":67,"correct":22},{"key":31,"text":69,"correct":26},{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":20,"analysis":33},960284,"火灾报警控制器发出或接收到反映火灾信息的声、光、电信号时所处的状态是（ ）。",[336,338,340,342],{"key":20,"text":337,"correct":26},"火灾报警状态",{"key":24,"text":339,"correct":22},"自检状态",{"key":28,"text":341,"correct":22},"屏蔽状态",{"key":31,"text":343,"correct":22},"故障报警状态",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},960285,"当火灾报警控制器“备电工作”指示灯点，故障声光指示启动，在显示屏上应显示（ ）故障。",[348,350,352,354],{"key":20,"text":349,"correct":22},"备电",{"key":24,"text":351,"correct":26},"主电",{"key":28,"text":353,"correct":22},"报警",{"key":31,"text":355,"correct":22},"现场设备故障",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":28,"analysis":33},960286,"集中火灾报警控制器或火灾报警控制器安装在墙上时，其靠近门轴的侧面距墙不应小于（ ）m。",[360,362,364,366],{"key":20,"text":361,"correct":22},"0.3",{"key":24,"text":363,"correct":22},"0.4",{"key":28,"text":365,"correct":26},"0.5",{"key":31,"text":367,"correct":22},"0.6",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":24,"analysis":33},960287,"消防控制室值班人员接到报警信号后，应派一名值班人员立即携带（ ），迅速到达报警点确认。",[372,374,376,378],{"key":20,"text":373,"correct":22},"工具箱",{"key":24,"text":375,"correct":26},"对讲机",{"key":28,"text":377,"correct":22},"手电筒",{"key":31,"text":379,"correct":22},"急救包",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":20,"analysis":33},960288,"图1所示的各图标中是扬声器的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":26},"④",{"key":24,"text":387,"correct":22},"⑥",{"key":28,"text":389,"correct":22},"⑨",{"key":31,"text":391,"correct":22},"⑩",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":24,"analysis":33},960289,"消防控制室是设有火灾自动报警设备和消防设施控制设备，用于接收、显示、处理火灾报警信号，控制相关（ ）的专门处所。",[396,398,400,401],{"key":20,"text":397,"correct":22},"电脑设备",{"key":24,"text":399,"correct":26},"消防设施",{"key":28,"text":137,"correct":22},{"key":31,"text":402,"correct":22},"防盗设备",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":28,"analysis":33},960290,"发生火警时，火灾报警控制器所连接的声光警报器将发出报警声，提示现场人员有火警存在，如果值班人员发现不是真实火警时，可以首先对其进行（ ）操作。",[407,409,411,413],{"key":20,"text":408,"correct":22},"联动",{"key":24,"text":410,"correct":22},"自检",{"key":28,"text":412,"correct":26},"警报器消音",{"key":31,"text":183,"correct":22},{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":31,"analysis":33},960291,"消防控制室是设有火灾自动报警设备和消防设施控制设备，用于接收、显示、处理（ ），控制相关消防设施的专门处所。",[418,420,422,424],{"key":20,"text":419,"correct":22},"安全信息",{"key":24,"text":421,"correct":22},"设备信息",{"key":28,"text":423,"correct":22},"通讯信号",{"key":31,"text":425,"correct":26},"火灾报警信号",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":24,"analysis":33},960292,"火灾报警控制器操作面板上具有（ ）键，按下此键能检查本机火灾报警功能，可对火灾报警控制器的音响器件、面板上所有指示灯（器）、显示器进行检查。",[430,432,434,436],{"key":20,"text":431,"correct":22},"“联动”",{"key":24,"text":433,"correct":26},"“自检”",{"key":28,"text":435,"correct":22},"“消音”",{"key":31,"text":437,"correct":22},"“复位”",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":31,"analysis":33},960293,"火灾自动报警设备的“自检键”的功能（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"检查建筑物内的各种探头是否处于正常工作状态",{"key":24,"text":445,"correct":22},"检查建筑物内的各种消防设备是否处于正常工作状态",{"key":28,"text":447,"correct":22},"检查建筑物内的消防管线是否处于正常工作状态",{"key":31,"text":449,"correct":26},"检查火灾报警控制器本身性能是否处于正常工作状态",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":33},960294,"在火灾报警控制器的工作原理中，通过（ ），负责提供控制器连接的探测器等现场设备供电，与探测器等现场设备进行通讯，完成对探测器等现场设备状态的状态监视和控制。",[454,456,458,460],{"key":20,"text":455,"correct":26},"总线驱动单元",{"key":24,"text":457,"correct":22},"显示键盘操作单元",{"key":28,"text":459,"correct":22},"通信接口单元",{"key":31,"text":461,"correct":22},"输入输出接口单元",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":24,"analysis":33},960295,"消防控制室值班期间，每班不应少于（ ）人。",[466,467,468,469],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"key":28,"text":29,"correct":22},{"key":31,"text":470,"correct":22},"4",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":24,"analysis":33},960296,"下列属于火灾报警系统中“感觉器官”的是（ ）。",[475,477,478,479],{"key":20,"text":476,"correct":22},"火灾报警控制器",{"key":24,"text":219,"correct":26},{"key":28,"text":67,"correct":22},{"key":31,"text":480,"correct":22},"火灾显示盘",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":20,"analysis":33},960297,"下列属于火灾报警系统中“大脑”的是（ ）。",[485,486,487,488],{"key":20,"text":476,"correct":26},{"key":24,"text":219,"correct":22},{"key":28,"text":67,"correct":22},{"key":31,"text":480,"correct":22},{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":31,"analysis":33},960298,"为使火灾自动报警系统或系统内各组成部分恢复到正常监视状态进行的操作是（ ）。",[493,494,495,496],{"key":20,"text":408,"correct":22},{"key":24,"text":410,"correct":22},{"key":28,"text":185,"correct":22},{"key":31,"text":183,"correct":26},{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":31,"analysis":33},960299,"火灾报警控制器备用电源部分发生故障并发出声、光报警所处的状态是（ ）。",[501,503,504,505],{"key":20,"text":502,"correct":22},"正常监视状态",{"key":24,"text":339,"correct":22},{"key":28,"text":341,"correct":22},{"key":31,"text":506,"correct":26},"备电故障报警状态",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":20,"analysis":33},960300,"消防控制室值班人员做交接班工作时，要认真填写（ ）及系统运行登记表和控制器日检登记表。",[511,513,515,517],{"key":20,"text":512,"correct":26},"值班记录",{"key":24,"text":514,"correct":22},"检查记录",{"key":28,"text":516,"correct":22},"故障记录",{"key":31,"text":518,"correct":22},"人员登记表",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":31,"analysis":33},960301,"火灾报警控制器火警信息的光指示信号不能自动清除，只能通过手动（ ）操作进行清除。",[523,524,525,526],{"key":20,"text":410,"correct":22},{"key":24,"text":189,"correct":22},{"key":28,"text":185,"correct":22},{"key":31,"text":183,"correct":26},{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":31,"analysis":33},960302,"火灾报警控制器主电电源部分发生故障并发出声、光报警所处的状态是（ ）。",[531,532,533,534],{"key":20,"text":502,"correct":22},{"key":24,"text":339,"correct":22},{"key":28,"text":341,"correct":22},{"key":31,"text":535,"correct":26},"主电故障报警状态",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":31,"analysis":33},960303,"（ ）是建筑消防设施日常管理和火警应急处理的专用场所。",[540,541,543,545],{"key":20,"text":113,"correct":22},{"key":24,"text":542,"correct":22},"安防保安室",{"key":28,"text":544,"correct":22},"门卫传达室",{"key":31,"text":117,"correct":26},{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":24,"analysis":33},960304,"一旦出现火情，消防控制室将成为紧急信息汇集、显示、处理的中心，（ ）控制各种相关设备，达到疏导和保护人员、控制和扑灭火灾的目的。",[550,552,554,556],{"key":20,"text":551,"correct":22},"最方便地",{"key":24,"text":553,"correct":26},"正确、迅速地",{"key":28,"text":555,"correct":22},"人工手动",{"key":31,"text":557,"correct":22},"有条件地",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":28,"analysis":33},960305,"集中火灾报警控制器或火灾报警控制器安装在墙上时，其底边距地面高度宜为（ ）m。",[562,564,566,568],{"key":20,"text":563,"correct":22},"1.1~1.3",{"key":24,"text":565,"correct":22},"1.2~1.4",{"key":28,"text":567,"correct":26},"1.3~1.5",{"key":31,"text":569,"correct":22},"1.4~1.6",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":31,"analysis":33},960306,"控制器处于“手动允许”的状态下时，下列叙述不正确的是（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"屏幕下方的状态栏显示手动允许状态",{"key":24,"text":577,"correct":22},"通过主控键盘可发出手动启动命令",{"key":28,"text":579,"correct":22},"手动消防启动盘可发出手动启动命令",{"key":31,"text":581,"correct":26},"多线制控制盘不能发出手动启动命令",[583,586,589,592,595,598],{"id":15,"name":584,"category":7,"favorite":585},"领导干部任职前廉政法规知识测试题",92,{"id":587,"name":588,"category":7,"favorite":15},595,"建筑结构与设备",{"id":590,"name":591,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":593,"name":594,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":596,"name":597,"category":7,"favorite":8},534,"BIM工程师",{"id":599,"name":597,"category":7,"favorite":8},535]