[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-699-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":594},{"id":5,"name":6,"category":7,"favorite":8},699,"初级技能","建筑工程",0,1,50,1301,[13,33,45,57,68,79,88,100,112,124,133,141,153,162,171,183,195,207,219,228,239,247,259,270,282,294,306,318,330,342,354,366,378,390,402,414,426,438,450,462,474,486,498,510,522,534,546,558,570,582],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":29,"analysis":32},959725,"单选题","当火灾报警控制器内部、火灾报警控制器与其连接的部件间发生故障时，火灾报警控制器在（ ）内发出与火灾报警信号有明显区别的故障声、光信号。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","10s",false,{"key":23,"text":24,"correct":21},"B","30s",{"key":26,"text":27,"correct":21},"C","60s",{"key":29,"text":30,"correct":31},"D","100s",true,"",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":35,"options":36,"answer":26,"analysis":32},959726,"根据《火灾报警控制器》（GB4717-2005）的有关规定，火灾报警控制器断电后，其运行数据存储单元虽然自动进入保护状态，但断电前存储的数据一般仅能保存（ ）天。",[37,39,41,43],{"key":19,"text":38,"correct":21},"7",{"key":23,"text":40,"correct":21},"10",{"key":26,"text":42,"correct":31},"14",{"key":29,"text":44,"correct":21},"30",{"id":46,"libraryId":5,"type":9,"typeLabel":15,"stem":47,"options":48,"answer":19,"analysis":32},959727,"下列属于手动报警按钮误报的原因的是（ ）。",[49,51,53,55],{"key":19,"text":50,"correct":31},"按钮在无火情的情况下被人为按下",{"key":23,"text":52,"correct":21},"现场环境空气洁净度不够或探测灵敏度等级设置不合理",{"key":26,"text":54,"correct":21},"水蒸气、扬尘、潮湿等环境因素所致",{"key":29,"text":56,"correct":21},"长期灰尘累积",{"id":58,"libraryId":5,"type":9,"typeLabel":15,"stem":59,"options":60,"answer":29,"analysis":32},959728,"下列不属于点型感烟火灾探测器误报原因的是（ ）。",[61,63,64,66],{"key":19,"text":62,"correct":21},"烹饪油烟、吸烟、杀虫剂等人为原因造成",{"key":23,"text":54,"correct":21},{"key":26,"text":65,"correct":21},"探测器长期灰尘累积",{"key":29,"text":67,"correct":31},"探测器使用环境存在快速温升",{"id":69,"libraryId":5,"type":9,"typeLabel":15,"stem":70,"options":71,"answer":29,"analysis":32},959729,"下列不属于吸气式感烟火灾探测器误报原因的是（ ）。",[72,74,76,78],{"key":19,"text":73,"correct":21},"现场环境空气洁净度不够",{"key":23,"text":75,"correct":21},"探测灵敏度等级设置不合理",{"key":26,"text":77,"correct":21},"过滤器污染",{"key":29,"text":67,"correct":31},{"id":80,"libraryId":5,"type":9,"typeLabel":15,"stem":81,"options":82,"answer":26,"analysis":32},959730,"下列属于火焰探测器误报原因的是（ ）。",[83,84,85,87],{"key":19,"text":73,"correct":21},{"key":23,"text":75,"correct":21},{"key":26,"text":86,"correct":31},"存在对应敏感光谱波段内的干扰光源",{"key":29,"text":67,"correct":21},{"id":89,"libraryId":5,"type":9,"typeLabel":15,"stem":90,"options":91,"answer":19,"analysis":32},959731,"当发生监管报警时，下列关于监管报警的处理方法错误的是（ ）。",[92,94,96,98],{"key":19,"text":93,"correct":31},"首先应按火灾报警控制器的“复位”键，恢复控制器监管警报",{"key":23,"text":95,"correct":21},"然后根据火灾报警控制器的报警信息检查发生监管报警的部位，确认是否有监管报警发生",{"key":26,"text":97,"correct":21},"若确认有监管报警发生，应根据监管的外部设备类型采取相应措施",{"key":29,"text":99,"correct":21},"若为误报警，应检查是否由于监管模块误动作，或者由于人为或其他因素造成误报警",{"id":101,"libraryId":5,"type":9,"typeLabel":15,"stem":102,"options":103,"answer":29,"analysis":32},959732,"下列不属于控制器主电故障原因的是（ ）。",[104,106,108,110],{"key":19,"text":105,"correct":21},"市电停电",{"key":23,"text":107,"correct":21},"电源线接触不良",{"key":26,"text":109,"correct":21},"主电熔断器熔断",{"key":29,"text":111,"correct":31},"控制器损坏",{"id":113,"libraryId":5,"type":9,"typeLabel":15,"stem":114,"options":115,"answer":23,"analysis":32},959733,"火灾报警控制器发出并显示火警信号后的操作错误的是（ ）。",[116,118,120,122],{"key":19,"text":117,"correct":21},"消防值班人员应首先按下“消音”键消音，再根据火灾报警控制器显示的火警信息确定报警点的具体位置",{"key":23,"text":119,"correct":31},"随后消防值班人员到现场进行火灾确认",{"key":26,"text":121,"correct":21},"当确有火灾发生时，现场人员需要立即使用对讲机或附近的消防电话分机向消防控制室反馈火灾确认信息，并需根据火灾燃烧规模情况决定利用现场附近灭火器材进行现场扑救或立即疏散转移人员",{"key":29,"text":123,"correct":21},"值班人员在接到现场火灾确认信息后，必须立即启动警报装置，同时拨打“119”火警电话向“119”火警调度指挥平台报告火警",{"id":125,"libraryId":5,"type":9,"typeLabel":15,"stem":126,"options":127,"answer":29,"analysis":32},959734,"火灾报警控制器对来自火灾探测器的火灾报警信号可设置报警延时，其最大延时不超过（ ），延时期间有延时光指示信号。",[128,130,131,132],{"key":19,"text":129,"correct":21},"3s",{"key":23,"text":20,"correct":21},{"key":26,"text":24,"correct":21},{"key":29,"text":27,"correct":31},{"id":134,"libraryId":5,"type":9,"typeLabel":15,"stem":135,"options":136,"answer":29,"analysis":32},959735,"如果在接收到第一个火灾报警信号后的（ ）内，火灾报警控制器接收到符合要求的后续火灾报警信号，则火灾报警控制器发出火灾报警声、光信号，并进入火灾报警状态。",[137,138,139,140],{"key":19,"text":129,"correct":21},{"key":23,"text":20,"correct":21},{"key":26,"text":24,"correct":21},{"key":29,"text":27,"correct":31},{"id":142,"libraryId":5,"type":9,"typeLabel":15,"stem":143,"options":144,"answer":26,"analysis":32},959736,"如果在接收到第一个火灾报警信号后的（ ）内，火灾报警控制器一直未接收到符合要求的后续火灾报警信号，则第一个火灾报警信号将自动复位。",[145,147,149,151],{"key":19,"text":146,"correct":21},"1min",{"key":23,"text":148,"correct":21},"10min",{"key":26,"text":150,"correct":31},"30min",{"key":29,"text":152,"correct":21},"60min",{"id":154,"libraryId":5,"type":9,"typeLabel":15,"stem":155,"options":156,"answer":23,"analysis":32},959737,"如果在接收到第一个火灾报警信号后的规定时间内不少于（ ），火灾报警控制器一直未接收到符合要求的后续火灾报警信号，可对第一个火灾报警信号自动复位。",[157,158,160,161],{"key":19,"text":146,"correct":21},{"key":23,"text":159,"correct":31},"5min",{"key":26,"text":148,"correct":21},{"key":29,"text":150,"correct":21},{"id":163,"libraryId":5,"type":9,"typeLabel":15,"stem":164,"options":165,"answer":23,"analysis":32},959738,"火灾报警控制器设有手动复位按钮（键）。手动复位后，火灾报警控制器将保持仍然存在的状态及相关信息或在（ ）内重新建立。",[166,167,169,170],{"key":19,"text":20,"correct":21},{"key":23,"text":168,"correct":31},"20s",{"key":26,"text":24,"correct":21},{"key":29,"text":27,"correct":21},{"id":172,"libraryId":5,"type":9,"typeLabel":15,"stem":173,"options":174,"answer":23,"analysis":32},959739,"下列不属于火灾报警控制器报警信息的是（ ）。",[175,177,179,181],{"key":19,"text":176,"correct":21},"火灾报警信息",{"key":23,"text":178,"correct":31},"信息类别",{"key":26,"text":180,"correct":21},"监管报警信息",{"key":29,"text":182,"correct":21},"故障报警信息",{"id":184,"libraryId":5,"type":9,"typeLabel":15,"stem":185,"options":186,"answer":26,"analysis":32},959740,"火灾报警控制器运行数据存储单元能记录消防设备运行状态信息，下列关于其记录信息说法错误的是（ ）。",[187,189,191,193],{"key":19,"text":188,"correct":21},"与火灾报警控制器连接的全部火灾报警触发器件的火灾报警信息、屏蔽状态信息、故障报警信息、监管报警信息、手动\u002F自动状态信息等消防设备运行状态信息",{"key":23,"text":190,"correct":21},"联动控制启动按钮（键）的动作信息",{"key":26,"text":192,"correct":31},"与火灾报警控制器连接的全部火灾报警触发器件的启动信息、反馈信息、屏蔽状态信息、报警故障信息、手动\u002F自动状态信息等消防设备运行状态信息",{"key":29,"text":194,"correct":21},"火灾报警控制器的开机、关机和复位、检查、时钟调整等操作信息",{"id":196,"libraryId":5,"type":9,"typeLabel":15,"stem":197,"options":198,"answer":26,"analysis":32},959741,"下列关于火灾报警的核实说法错误的是（ ）。",[199,201,203,205],{"key":19,"text":200,"correct":21},"首先查看火灾报警控制器的火灾报警信息，确定触发火灾报警的触发器件类型和报警部位",{"key":23,"text":202,"correct":21},"若该触发器件所在区域有视频监控，应第一时间利用视频监控确认火警",{"key":26,"text":204,"correct":31},"该触发器件所在区域没有视频监控，或者视频监控无法准确确认，则应立即前往现场，确认是否有火灾发生",{"key":29,"text":206,"correct":21},"若确认有火灾发生，应立即拨打“119”火警电话报警，通知单位负责人，启动应急预案，开展初期火灾处置",{"id":208,"libraryId":5,"type":9,"typeLabel":15,"stem":209,"options":210,"answer":23,"analysis":32},959742,"火灾报警控制器的监管报警信号是非火警状态下重要消防设施、设备的状态信号，同样需要尽快核实处置。下列关于监管报警信息的核实说法错误的是（ ）。",[211,213,215,217],{"key":19,"text":212,"correct":21},"首先查看控制器中监管报警信息，确认触发监管报警的触发器件类型和其所在部位，做好监管报警记录",{"key":23,"text":214,"correct":31},"再根据触发器件及其状态信息的具体情况，由控制室值班人员到现场核实监管报警信息",{"key":26,"text":216,"correct":21},"若确认是由火灾引起的设备联动情况，应立即查找火源，确认火情，并进行火灾上报和处置",{"key":29,"text":218,"correct":21},"若仔细检査现场没有发生火灾情况，可认为是设备误动作或者设备故障，应按误报进行处置",{"id":220,"libraryId":5,"type":9,"typeLabel":15,"stem":221,"options":222,"answer":29,"analysis":32},959743,"下列属于线型红外光束感烟火灾探测器误报原因的是（ ）。",[223,224,225,226],{"key":19,"text":62,"correct":21},{"key":23,"text":54,"correct":21},{"key":26,"text":65,"correct":21},{"key":29,"text":227,"correct":31},"光束通道存在部分被遮挡",{"id":229,"libraryId":5,"type":9,"typeLabel":15,"stem":230,"options":231,"answer":26,"analysis":32},959744,"下列不属于火灾探测器类故障的原因是（ ）。",[232,234,236,237],{"key":19,"text":233,"correct":21},"探测器与底座脱落，接触不良",{"key":23,"text":235,"correct":21},"总线与底座接触不良",{"key":26,"text":107,"correct":31},{"key":29,"text":238,"correct":21},"探测器损坏",{"id":240,"libraryId":5,"type":9,"typeLabel":15,"stem":241,"options":242,"answer":19,"analysis":32},959745,"下列属于手动火灾报警按钮故障的原因是（ ）。",[243,244,245,246],{"key":19,"text":233,"correct":31},{"key":23,"text":235,"correct":21},{"key":26,"text":107,"correct":21},{"key":29,"text":238,"correct":21},{"id":248,"libraryId":5,"type":9,"typeLabel":15,"stem":249,"options":250,"answer":19,"analysis":32},959747,"（ ）是用于控制灭火剂间歇喷射和为灭火剂喷射流导向的部件。",[251,253,255,257],{"key":19,"text":252,"correct":31},"喷射控制枪",{"key":23,"text":254,"correct":21},"喷嘴",{"key":26,"text":256,"correct":21},"喷射软管组件",{"key":29,"text":258,"correct":21},"喷射管组件",{"id":260,"libraryId":5,"type":9,"typeLabel":15,"stem":261,"options":262,"answer":19,"analysis":32},959748,"下列不属于点型感烟火灾探测器误报警原因的是（ ）。",[263,264,266,268],{"key":19,"text":50,"correct":31},{"key":23,"text":265,"correct":21},"烹饪油烟所致",{"key":26,"text":267,"correct":21},"扬尘环境因素所致",{"key":29,"text":269,"correct":21},"禁止吸烟场所吸烟",{"id":271,"libraryId":5,"type":9,"typeLabel":15,"stem":272,"options":273,"answer":26,"analysis":32},959749,"当市政给水管网不能完全保证室外消防给水设计流量时，消防水池的有效容积说法符合要求的是（ ）。",[274,276,278,280],{"key":19,"text":275,"correct":21},"消防水池应按室外消防用水量设计",{"key":23,"text":277,"correct":21},"消防水池应按室外和室内的消防用水量设计",{"key":26,"text":279,"correct":31},"消防水池应按室内消防用水量和室外消防用水量不足部分之和设计",{"key":29,"text":281,"correct":21},"消防水池应按室内消防用水量设计",{"id":283,"libraryId":5,"type":9,"typeLabel":15,"stem":284,"options":285,"answer":23,"analysis":32},959750,"触发常开防火门所在区域的火灾探测器，下列动作不正确的是（ ）。",[286,288,290,292],{"key":19,"text":287,"correct":21},"火灾报警控制器处于自动状态时，防火门应自动关闭",{"key":23,"text":289,"correct":31},"火灾报警控制器处于手动状态时，防火门应自动关闭",{"key":26,"text":291,"correct":21},"监控器主面板的启动指示灯点亮，屏幕显示启动信息",{"key":29,"text":293,"correct":21},"防火门关闭信号反馈至消防控制室",{"id":295,"libraryId":5,"type":9,"typeLabel":15,"stem":296,"options":297,"answer":29,"analysis":32},959751,"下列对火灾报警控制器的监管报警信息核实不正确的是（ ）。",[298,300,302,304],{"key":19,"text":299,"correct":21},"监管报警信号需要尽快核实处置",{"key":23,"text":301,"correct":21},"确认触发监管报警的触发器件类型和其所在部位",{"key":26,"text":303,"correct":21},"报警区域的值班人员到现场核实监管报警信息",{"key":29,"text":305,"correct":31},"通知单位负责人，启动应急预案",{"id":307,"libraryId":5,"type":9,"typeLabel":15,"stem":308,"options":309,"answer":29,"analysis":32},959752,"下列不属于火灾自动报警系统分类的是（ ）。",[310,312,314,316],{"key":19,"text":311,"correct":21},"区域报警系统",{"key":23,"text":313,"correct":21},"集中报警系统",{"key":26,"text":315,"correct":21},"控制中心报警系统",{"key":29,"text":317,"correct":31},"局部报警系统",{"id":319,"libraryId":5,"type":9,"typeLabel":15,"stem":320,"options":321,"answer":29,"analysis":32},959753,"自检过程中，下列状态不属于故障状态的是（ ）。",[322,324,326,328],{"key":19,"text":323,"correct":21},"液晶屏像素点不完整或数码管显示缺划，",{"key":23,"text":325,"correct":21},"打印机打印不正确",{"key":26,"text":327,"correct":21},"火灾报警控制器无火警、监管、故障三种声音发出",{"key":29,"text":329,"correct":31},"总线手动控制单元和直接手动控制单元所有指示灯点亮",{"id":331,"libraryId":5,"type":9,"typeLabel":15,"stem":332,"options":333,"answer":26,"analysis":32},959754,"自动排气阀密封性能要求，低压水密封应保持（ ）无可见渗漏。",[334,336,338,340],{"key":19,"text":335,"correct":21},"公称压力的1.1倍，持压1min",{"key":23,"text":337,"correct":21},"公称压力的1.1倍，持压3min",{"key":26,"text":339,"correct":31},"公称压力为0.02MPa，持压1min",{"key":29,"text":341,"correct":21},"公称压力为0.02MPa，持压3min",{"id":343,"libraryId":5,"type":9,"typeLabel":15,"stem":344,"options":345,"answer":26,"analysis":32},959756,"当有火灾探测器火灾报警信号输入时，区域型火灾报警控制器在（ ）内发出火灾报警声、光信号。",[346,348,350,352],{"key":19,"text":347,"correct":21},"3S",{"key":23,"text":349,"correct":21},"5S",{"key":26,"text":351,"correct":31},"10S",{"key":29,"text":353,"correct":21},"20S",{"id":355,"libraryId":5,"type":9,"typeLabel":15,"stem":356,"options":357,"answer":19,"analysis":32},959757,"关于设置高位消防水箱的目的，下列说法中错误的是（ ）。",[358,360,362,364],{"key":19,"text":359,"correct":31},"储存火灾延续时间内各种消防设施的全部消防用水量",{"key":23,"text":361,"correct":21},"提供水灭火系统启动初期的消防用水量",{"key":26,"text":363,"correct":21},"提供水灭火系统启动初期的消防用水压",{"key":29,"text":365,"correct":21},"利用高位差为系统提供准工作状态下所需的水压",{"id":367,"libraryId":5,"type":9,"typeLabel":15,"stem":368,"options":369,"answer":19,"analysis":32},959758,"下列功能不属于火灾报警控制器的报警功能的是（ ）。",[370,372,374,376],{"key":19,"text":371,"correct":31},"录像功能",{"key":23,"text":373,"correct":21},"监管功能",{"key":26,"text":375,"correct":21},"故障报警功能",{"key":29,"text":377,"correct":21},"屏蔽功能",{"id":379,"libraryId":5,"type":9,"typeLabel":15,"stem":380,"options":381,"answer":23,"analysis":32},959759,"下列灭火剂代号中，（ ）代表的是水基型灭火器。",[382,384,386,388],{"key":19,"text":383,"correct":21},"F",{"key":23,"text":385,"correct":31},"S",{"key":26,"text":387,"correct":21},"T",{"key":29,"text":389,"correct":21},"J",{"id":391,"libraryId":5,"type":9,"typeLabel":15,"stem":392,"options":393,"answer":23,"analysis":32},959760,"下列自动排气阀按进出口连接方式分类的是（ ）。",[394,396,398,400],{"key":19,"text":395,"correct":21},"分体式",{"key":23,"text":397,"correct":31},"法兰式",{"key":26,"text":399,"correct":21},"卡箍式",{"key":29,"text":401,"correct":21},"卡套式",{"id":403,"libraryId":5,"type":9,"typeLabel":15,"stem":404,"options":405,"answer":23,"analysis":32},959761,"下列信息特征中，（ ）不能判断火灾报警控制器进入火灾报警状态。",[406,408,410,412],{"key":19,"text":407,"correct":21},"专用火警总指示灯点亮",{"key":23,"text":409,"correct":31},"专用监管报警状态总指示灯点亮",{"key":26,"text":411,"correct":21},"音响器件发出消防车警报声",{"key":29,"text":413,"correct":21},"显示器显示火灾报警时间、部位及注释信息",{"id":415,"libraryId":5,"type":9,"typeLabel":15,"stem":416,"options":417,"answer":19,"analysis":32},959762,"下列属于微型消防站类别的是（ ）。",[418,420,422,424],{"key":19,"text":419,"correct":31},"社区微型消防站",{"key":23,"text":421,"correct":21},"普通单位微型消防站",{"key":26,"text":423,"correct":21},"消防支队",{"key":29,"text":425,"correct":21},"消防检测机构",{"id":427,"libraryId":5,"type":9,"typeLabel":15,"stem":428,"options":429,"answer":29,"analysis":32},959763,"消防水源是指开展消防工作时所需要的水源，下列不属于消防水源的是（ ）。",[430,432,434,436],{"key":19,"text":431,"correct":21},"天然水源",{"key":23,"text":433,"correct":21},"消防水池",{"key":26,"text":435,"correct":21},"市政供水管网",{"key":29,"text":437,"correct":31},"水泵接合器",{"id":439,"libraryId":5,"type":9,"typeLabel":15,"stem":440,"options":441,"answer":29,"analysis":32},959764,"下列组件中不属于防火卷帘组件的是（ ）。",[442,444,446,448],{"key":19,"text":443,"correct":21},"卷轴",{"key":23,"text":445,"correct":21},"导轨",{"key":26,"text":447,"correct":21},"帘面",{"key":29,"text":449,"correct":31},"防护冷却系统",{"id":451,"libraryId":5,"type":9,"typeLabel":15,"stem":452,"options":453,"answer":26,"analysis":32},959765,"下列组件属于阀门启闭件是（ ）。",[454,456,458,460],{"key":19,"text":455,"correct":21},"阀杆",{"key":23,"text":457,"correct":21},"垫片",{"key":26,"text":459,"correct":31},"闸板",{"key":29,"text":461,"correct":21},"驱动装置",{"id":463,"libraryId":5,"type":9,"typeLabel":15,"stem":464,"options":465,"answer":26,"analysis":32},959766,"利用出口压力变化直接控制阀瓣运动的减压阀属于哪种分类的减压阀（ ）。",[466,468,470,472],{"key":19,"text":467,"correct":21},"先导式可调减压阀",{"key":23,"text":469,"correct":21},"薄膜式减压阀",{"key":26,"text":471,"correct":31},"直接作用式减压阀",{"key":29,"text":473,"correct":21},"活塞式减压阀",{"id":475,"libraryId":5,"type":9,"typeLabel":15,"stem":476,"options":477,"answer":19,"analysis":32},959767,"具有监管报警功能的火灾自动报警控制器在接到常闭防火门打开的信号后，在（ ）内发出监管报警声、光信号。",[478,480,482,484],{"key":19,"text":479,"correct":31},"100S",{"key":23,"text":481,"correct":21},"120S",{"key":26,"text":483,"correct":21},"60S",{"key":29,"text":485,"correct":21},"30S",{"id":487,"libraryId":5,"type":9,"typeLabel":15,"stem":488,"options":489,"answer":23,"analysis":32},959768,"建筑高度150米的住宅，高位消防水箱满足要求的最小有效容积和最不利点静压的是（ ）。",[490,492,494,496],{"key":19,"text":491,"correct":21},"18m3和0.07MP",{"key":23,"text":493,"correct":31},"36m3和0.07MP",{"key":26,"text":495,"correct":21},"50m3和0.1MP",{"key":29,"text":497,"correct":21},"100m3和0.1MPa",{"id":499,"libraryId":5,"type":9,"typeLabel":15,"stem":500,"options":501,"answer":26,"analysis":32},959769,"当火灾报警探测器出现故障时，下列不能确认探测器故障位置的是（ ）。",[502,504,506,508],{"key":19,"text":503,"correct":21},"火灾探测报警系统图",{"key":23,"text":505,"correct":21},"火灾探测器系统部件现场布置图",{"key":26,"text":507,"correct":31},"火灾报警控制器显示的火警信息",{"key":29,"text":509,"correct":21},"地址编码表",{"id":511,"libraryId":5,"type":9,"typeLabel":15,"stem":512,"options":513,"answer":23,"analysis":32},959770,"不属于闸阀的常用驱动方式的是（ ）。",[514,516,518,520],{"key":19,"text":515,"correct":21},"手动",{"key":23,"text":517,"correct":31},"易熔原件",{"key":26,"text":519,"correct":21},"液压",{"key":29,"text":521,"correct":21},"气动",{"id":523,"libraryId":5,"type":9,"typeLabel":15,"stem":524,"options":525,"answer":19,"analysis":32},959771,"阀门井内的闸阀应采用（ ）。",[526,528,530,532],{"key":19,"text":527,"correct":31},"耐腐蚀的明杆闸阀",{"key":23,"text":529,"correct":21},"耐腐蚀的暗杆闸阀",{"key":26,"text":531,"correct":21},"明杆闸阀",{"key":29,"text":533,"correct":21},"带启闭刻度的暗杆闸阀",{"id":535,"libraryId":5,"type":9,"typeLabel":15,"stem":536,"options":537,"answer":26,"analysis":32},959772,"对于手动火灾报警按钮误报处理方法正确的是（ ）。",[538,540,542,544],{"key":19,"text":539,"correct":21},"厂家或维保人员协助解决",{"key":23,"text":541,"correct":21},"重新设置报警灵敏度等级",{"key":26,"text":543,"correct":31},"使用专用工具复位",{"key":29,"text":545,"correct":21},"对相关人员进行培训，以杜绝人为因素",{"id":547,"libraryId":5,"type":9,"typeLabel":15,"stem":548,"options":549,"answer":26,"analysis":32},959773,"防火门是建筑中可活动的防火分隔设施之一，下列对防火门描述不正确的是（ ）。",[550,552,554,556],{"key":19,"text":551,"correct":21},"阻止火势蔓延",{"key":23,"text":553,"correct":21},"阻止烟气扩散",{"key":26,"text":555,"correct":31},"丙级防火门耐火极限不低于1.0h",{"key":29,"text":557,"correct":21},"甲级防火门耐火极限不低于1.5h",{"id":559,"libraryId":5,"type":9,"typeLabel":15,"stem":560,"options":561,"answer":19,"analysis":32},959774,"防火门监控器的屏幕显示描述正确的是（ ）。",[562,564,566,568],{"key":19,"text":563,"correct":31},"显示屏幕划分为上下两个部分",{"key":23,"text":565,"correct":21},"下部两行行用来显示被监控的防火门状态",{"key":26,"text":567,"correct":21},"上部四行用来显示火警、启动、反馈等事件信息",{"key":29,"text":569,"correct":21},"故障报警时，屏幕上的故障灯点亮",{"id":571,"libraryId":5,"type":9,"typeLabel":15,"stem":572,"options":573,"answer":26,"analysis":32},959775,"防火门的复位操作正确的是（ ）。",[574,576,578,580],{"key":19,"text":575,"correct":21},"自动复位",{"key":23,"text":577,"correct":21},"远程手动复位",{"key":26,"text":579,"correct":31},"现场手动复位",{"key":29,"text":581,"correct":21},"联动复位",{"id":583,"libraryId":5,"type":9,"typeLabel":15,"stem":584,"options":585,"answer":29,"analysis":32},959776,"下列关于灭火器外部可视零部件的功能，描述正确的是（ ）。",[586,588,590,592],{"key":19,"text":587,"correct":21},"压力显示器是防止误操作的部件",{"key":23,"text":589,"correct":21},"封记是用于识别灭火器筒体内压力的元件",{"key":26,"text":591,"correct":21},"保险装置是用于识别灭火器是否被启用过的部件",{"key":29,"text":593,"correct":31},"当瓶体内气体压力超过设计规定时，超压安全保护装置用于释放瓶体内部气体",[595,598,601,604,607,610],{"id":9,"name":596,"category":7,"favorite":597},"领导干部任职前廉政法规知识测试题",92,{"id":599,"name":600,"category":7,"favorite":9},595,"建筑结构与设备",{"id":602,"name":603,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":605,"name":606,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":608,"name":609,"category":7,"favorite":8},534,"BIM工程师",{"id":611,"name":609,"category":7,"favorite":8},535]