[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-960529":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},960529,699,2,"多选题","下列属于每月应对消防水池、高位消防水箱进行保养的是（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","对消防水池、高位消防水箱等消防水源设施的水位进行一次检测",true,{"key":16,"text":17,"correct":18},"B","应检查承重结构、孔口、基础、检修通道或梯子的明显损害或破损",false,{"key":20,"text":21,"correct":18},"C","检查消防水池、消防水箱等蓄水设施的结构材料是否完好",{"key":23,"text":24,"correct":14},"D","检查消防用水不作他用的技术措施，发现故障应及时进行处理",{"key":26,"text":27,"correct":18},"E","检查水池（箱）周围有无可燃物，有无造成腐蚀和污染的物品","AD","每月应对消防水池、高位消防水箱等消防水源设施的水位进行一次检测；消防水池（箱）玻璃水位计两端的角阀在不进行水位观察时应关闭。检查消防用水不作他用的技术措施，发现故障应及时进行处理。当发现电子液位与机械液位（玻璃管液位计）等不一致时，应校核电子液位的准确性和合理性。 每季度外观检查应检查承重结构、孔口、基础、检修通道或梯子的明显损害或破损。承重结构还应检査腐蚀、腐烂、锈蚀、机械损坏、沉积的碎片、沉淀物。每季度检查水池（箱）周围有无可燃物，有无造成腐蚀和污染的物品，水池（箱）内冬季有无结冰。 每年应检查消防水池、消防水箱等蓄水设施的结构材料是否完好，发现问题及时处理。阴极保护每年按设计要求维修检查一次。进出水管上的阀门每年检查一次。伸缩接头每年检查是否漏水或破裂。",{"id":6,"name":31,"category":32,"favorite":33},"初级技能","建筑工程",0]