[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-960008":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},960008,699,1,"单选题","火灾警报装置保养内容错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","检査设备周围是否有遮挡物等影响设备运行的因素",false,{"key":16,"text":17,"correct":18},"B","检査设备接地线路截面积是否满足要求",true,{"key":20,"text":21,"correct":14},"C","启动火灾警报装置，观察声、光指示正常，并且在其正前方3m水平处，使用声级计测量声信号，应满足75~120d",{"key":23,"text":24,"correct":14},"D","定期检査接线端子与接线。接线端子应无松动、无锈蚀现象;接线应无锈蚀","火灾警报装置保养内容为：运行环境检査：检査设备周围是否有遮挡物等影响设备运行的因素（A正确）；设备外观检査：检査设备是否有破损现象；启动功能测试：启动火灾警报装置，观察声、光指示正常，并且在其正前方3m水平处，使用声级计测量声信号，应满足75~120dB（C正确）；接线端子检査：定期检査接线端子与接线。接线端子应无松动、无锈蚀现象;接线应无锈蚀（D正确）；B选项不属于保养内容，故B错误。",{"id":6,"name":27,"category":28,"favorite":29},"初级技能","建筑工程",0]