[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-959832":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},959832,699,1,"单选题","下列关于火灾报警控制器现场部件的检查内容说法错误的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","火灾报警控制器自检总指示灯（器）：当系统中存在处于自检状态的设备时，此灯熄灭；所有设备退岀自检状态后，此灯熄灭点亮",true,{"key":16,"text":17,"correct":18},"B","现场部件指示灯：下发自检命令后，检查现场部件的报警、动作、反馈、故障等指示灯是否能被点亮",false,{"key":20,"text":21,"correct":18},"C","现场部件显示功能：下发自检命令后，观察具有液晶或数码管显示的设备显示是否正常",{"key":23,"text":24,"correct":18},"D","现场部件报警功能：下发自检命令后，检查现场部件是否能够报警并正确上传","现场部件（仅限有此功能的火灾报警控制器）：火灾报警控制器自检总指示灯（器）：当系统中存在处于自检状态的设备时，此灯点亮；所有设备退岀自检状态后，此灯熄灭；现场部件指示灯：下发自检命令后，检查现场部件的报警、动作、反馈、故障等指示灯是否能被点亮；现场部件显示功能：下发自检命令后，观察具有液晶或数码管显示的设备显示是否正常；现场部件报警功能：下发自检命令后，检查现场部件是否能够报警并正确上传。",{"id":6,"name":27,"category":28,"favorite":29},"初级技能","建筑工程",0]