[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-957344":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},957344,693,1,"单选题","对于混凝土坝、闸基础与其地基土间的抗剪强度标准值的确定，下列选项中不正确的是( )。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","对于软土地基，力学参数标准值宜采用室内试验、原位测试，结合当地经验确定，抗剪强度指标室内宜采用三轴试验，原位测试宜采用十字板剪切试验",false,{"key":16,"text":17,"correct":14},"B","对于黏性土地基，内摩擦角标准值可采用室内饱和固结快剪试验内摩擦角平均值的90％，凝聚力标准值可采用室内饱和固结快剪试验凝聚力平均值的20％～30％",{"key":19,"text":20,"correct":14},"C","对于砂性土地基，内摩擦角标准值可采用室内饱和固结快剪试验内摩擦角平均值的85％～90％",{"key":22,"text":23,"correct":24},"D","对于碎石土地基，应以其中细粒土的抗剪强度确定其抗剪强度标准值",true,"根据《水利水电工程地质勘察规范》(GB50487—2008)第E.0.2条规定，混凝土坝、闸基础与地基土间的抗剪强度标准值应符合下列规定：①对黏性土地基，内摩擦角标准值可采用室内饱和固结快剪试验内摩擦角平均值的90%，凝聚力标准值可采用室内饱和固结快剪试验凝聚力平均值的20%～30%；②对砂性土地基，内摩擦角标准值可采用室内饱和固结快剪试验内摩擦角平均值的85～90%；③对软土地基，力学参数标准值宜采用室内试验、原位测试，结合当地经验确定。抗剪强度指标宜采用室内三轴压缩试验指标，原位测试宜采用十字板剪切试验。",{"id":6,"name":27,"category":28,"favorite":29},"专业案例（水利水电）","建筑工程",0]