[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-957338":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},957338,693,1,"单选题","当采用总应力进行稳定分析来选取地基土抗剪强度的标准值时，下列选项中不正确的是( )。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","对于黏性土地基，应测定或估算孔隙水压力，采用有效应力强度的标准值",true,{"key":16,"text":17,"correct":18},"B","对于排水条件差的黏性土地基，宜采用饱和恻剪强度标准值，或三轴不固结不排水剪切强度的标准值；对于软土地基，可采用原位十字板剪切强度标准值",false,{"key":20,"text":21,"correct":18},"C","对于上下土层透水性较好或采取了排水措施的薄层黏性土地基，宜采用饱和固结快剪强度标准值或三轴压缩试验固结不排水剪切强度标准值",{"key":23,"text":24,"correct":18},"D","对于透水性良好、不易产生孔隙水压力或能自由排水的地基土层，宜采用慢剪强度标准值或三轴压缩试验固结排水剪切强度标准值","根据《水利水电工程地质勘察规范》(GB50487—2008)第E.0.2条规定，当采用总应力进行稳定分析时，地基土抗剪强度的标准值应符合下列规定：①对排水条件差的教性土地基，宜采用饱和快剪强度或三轴压缩试验不固结不排水剪切强度；对软士可采用原位十字板剪切强度。②对上、下土层透水性较好或采取了排水措施的薄层黏性土地基，宜采用饱和固结快剪强度或三轴压缩试验固结不排水剪切强度。③对透水性良好，不易产生孔隙水压力或能自由排水的地基土层，宜采用慢剪强度或三轴压缩试验固结排水剪切强度。",{"id":6,"name":27,"category":28,"favorite":29},"专业案例（水利水电）","建筑工程",0]