[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-666-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":659},{"id":5,"name":6,"category":7,"favorite":8},666,"建筑电工","建筑工程",0,9,50,1106,[13,31,44,54,66,78,88,100,112,122,134,144,156,166,174,184,194,206,216,226,236,243,255,269,285,300,315,330,345,359,374,389,403,417,430,444,458,472,486,500,515,529,544,558,572,587,602,616,630,644],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},942803,1,"单选题","发生人身触电事故,在进行救护时,首先应采取什么措施?( )",[19,23,27],{"key":20,"text":21,"correct":22},"A","立即检查触电者是否还有心跳呼吸,如没有立即进行心肺复",false,{"key":24,"text":25,"correct":26},"B","立即断开电源使触电者与带电部分脱离",true,{"key":28,"text":29,"correct":22},"C","立即拨打120呼叫救护车","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},942804,"当PE线与相线材质相同时,相线截面>35mm2时,PE线截面为( )。",[35,37,39,41],{"key":20,"text":36,"correct":22},"16mm2",{"key":24,"text":38,"correct":26},"相线截面的一半",{"key":28,"text":40,"correct":22},"与相线相同",{"key":42,"text":43,"correct":22},"D","4mm2",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":24,"analysis":30},942805,"泡沫灭火剂,是扑救易燃可燃( )火灾的有效灭火剂。",[48,50,52],{"key":20,"text":49,"correct":22},"物体",{"key":24,"text":51,"correct":26},"液体",{"key":28,"text":53,"correct":22},"气体",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":24,"analysis":30},942806,"施工现场用电工程中,PE线上每处重复接地的接地电阻值不应大于( )。",[58,60,62,64],{"key":20,"text":59,"correct":22},"4Ω",{"key":24,"text":61,"correct":26},"10Ω",{"key":28,"text":63,"correct":22},"30Ω",{"key":42,"text":65,"correct":22},"100Ω",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":24,"analysis":30},942807,"照明系统中的每一单相回路上灯具和插座数量不宜超过 ( ) 个。",[70,72,74,76],{"key":20,"text":71,"correct":22},"20",{"key":24,"text":73,"correct":26},"25",{"key":28,"text":75,"correct":22},"30",{"key":42,"text":77,"correct":22},"40",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":20,"analysis":30},942808,"施工现场木工作业区,木器原料,成品堆放区属于( )动火区域。",[82,84,86],{"key":20,"text":83,"correct":26},"一级",{"key":24,"text":85,"correct":22},"二级",{"key":28,"text":87,"correct":22},"三级",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":42,"analysis":30},942809,"一般场所开关箱中漏电保护器,其额定漏电动作电流为( )。",[92,94,96,98],{"key":20,"text":93,"correct":22},"10mA",{"key":24,"text":95,"correct":22},"20mA",{"key":28,"text":97,"correct":22},"30mA",{"key":42,"text":99,"correct":26},"≯30mA",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":24,"analysis":30},942810,"配电箱、开关箱必须按照顺序操作,停电操作顺序为:( ),但出现电气故障的紧急情况可除外。",[104,106,108,110],{"key":20,"text":105,"correct":22},"总配电箱一分配电箱-开关箱",{"key":24,"text":107,"correct":26},"开关箱一分配电箱一总配电箱",{"key":28,"text":109,"correct":22},"分配电箱-开关箱一总配电箱",{"key":42,"text":111,"correct":22},"总配电箱一开关箱-分配电箱",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":24,"analysis":30},942811,"食堂工作人员要持( )证上岗,有良好卫生习惯。",[116,118,120],{"key":20,"text":117,"correct":22},"上岗",{"key":24,"text":119,"correct":26},"健康",{"key":28,"text":121,"correct":22},"饮事员等级",{"id":123,"libraryId":5,"type":15,"typeLabel":16,"stem":124,"options":125,"answer":42,"analysis":30},942812,"聚光灯、碘钨灯等高热灯具与易燃物距离不宜小于( ),且不得直接照射易燃物:达不到规定安全距离时,应采取隔热措施。",[126,128,130,132],{"key":20,"text":127,"correct":22},"200mm",{"key":24,"text":129,"correct":22},"300mm",{"key":28,"text":131,"correct":22},"400mm",{"key":42,"text":133,"correct":26},"500mm",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":28,"analysis":30},942813,"施工现场停止作业( )以上时,应将开关箱断电上锁。",[138,140,142],{"key":20,"text":139,"correct":22},"3小时",{"key":24,"text":141,"correct":22},"2小时",{"key":28,"text":143,"correct":26},"1小时",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":24,"analysis":30},942814,"电焊机一次侧电源线的长度不应大于( )。",[148,150,152,154],{"key":20,"text":149,"correct":22},"3m",{"key":24,"text":151,"correct":26},"5m",{"key":28,"text":153,"correct":22},"10m",{"key":42,"text":155,"correct":22},"15m",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":24,"analysis":30},942815,"冬季使用金属火炉取暖,应与可燃易燃材料的距离不小于( )。",[160,162,164],{"key":20,"text":161,"correct":22},"50cm",{"key":24,"text":163,"correct":26},"100cm",{"key":28,"text":165,"correct":22},"150cm",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":42,"analysis":30},942816,"PE线采用单芯绝缘导线时,按机械强度要求,其截面不应小于:有机械保护时2.5mm2,无机械保护时为( )。",[170,171,172,173],{"key":20,"text":36,"correct":22},{"key":24,"text":38,"correct":22},{"key":28,"text":40,"correct":22},{"key":42,"text":43,"correct":26},{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":28,"analysis":30},942817,"用齿轮传动代替皮带传动可以防止静电危害,其作用是什么?( )",[178,180,182],{"key":20,"text":179,"correct":22},"减少静电荷的积聚",{"key":24,"text":181,"correct":22},"中和静电荷",{"key":28,"text":183,"correct":26},"消除产生静电荷的根源",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":28,"analysis":30},942818,"下列哪种措施属电击防护措施中的直接接触防护?( )",[188,190,192],{"key":20,"text":189,"correct":22},"保护接地",{"key":24,"text":191,"correct":22},"漏电保护",{"key":28,"text":193,"correct":26},"绝缘",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":24,"analysis":30},942819,"架空线在跨越铁路、公路、河流、电力线路档距内,架空线( )接头。",[198,200,202,204],{"key":20,"text":199,"correct":22},"可以有",{"key":24,"text":201,"correct":26},"不得有",{"key":28,"text":203,"correct":22},"可以有一个",{"key":42,"text":205,"correct":22},"可以有两个",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":28,"analysis":30},942820,"进入建筑施工现场的人员都必须佩戴 ( )。",[210,212,214],{"key":20,"text":211,"correct":22},"手套",{"key":24,"text":213,"correct":22},"安全带",{"key":28,"text":215,"correct":26},"安全帽",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":24,"analysis":30},942821,"在金属球罐使用II类手持电动工具时,其电源线路上应装设什么保护装置?( )",[220,222,224],{"key":20,"text":221,"correct":22},"热继电器",{"key":24,"text":223,"correct":26},"漏电保护器",{"key":28,"text":225,"correct":22},"失压脱扣器",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":30},942822,"( )赋予作业人员有权拒绝违章指挥和强令昌险作业的权利。",[230,232,234],{"key":20,"text":231,"correct":26},"法律",{"key":24,"text":233,"correct":22},"国家",{"key":28,"text":235,"correct":22},"政府",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":28,"analysis":30},942823,"施工现场临时用电必须采用( )级配电系统。",[240,241,242],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":22},{"key":28,"text":87,"correct":26},{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":24,"analysis":30},942824,"高压指交流额定电压 ( ) 以上的电压。",[247,249,251,253],{"key":20,"text":248,"correct":22},"380V",{"key":24,"text":250,"correct":26},"1000V",{"key":28,"text":252,"correct":22},"2000V",{"key":42,"text":254,"correct":22},"10000V",{"id":256,"libraryId":5,"type":257,"typeLabel":258,"stem":259,"options":260,"answer":268,"analysis":30},942825,2,"多选题","一般场所必须使用额定漏电动作电流不大于( ),额定漏电动作时间应不大于( )的漏电保护器。",[261,262,264,266],{"key":20,"text":97,"correct":26},{"key":24,"text":263,"correct":22},"50mA",{"key":28,"text":265,"correct":26},"0.1S",{"key":42,"text":267,"correct":22},"0.2S","AC",{"id":270,"libraryId":5,"type":257,"typeLabel":258,"stem":271,"options":272,"answer":284,"analysis":30},942826,"熔断器选择的主要内容是( )。",[273,275,277,279,281],{"key":20,"text":274,"correct":26},"熔断器的型式",{"key":24,"text":276,"correct":26},"熔体的额定电流",{"key":28,"text":278,"correct":26},"熔体动作选择性的配合",{"key":42,"text":280,"correct":26},"熔断器额定电压",{"key":282,"text":283,"correct":26},"E","熔断器额定电流","ABCDE",{"id":286,"libraryId":5,"type":257,"typeLabel":258,"stem":287,"options":288,"answer":299,"analysis":30},942827,"刀开关在电路中的作用是( )。",[289,291,293,295,297],{"key":20,"text":290,"correct":26},"隔离电源",{"key":24,"text":292,"correct":26},"分段负载",{"key":28,"text":294,"correct":22},"控制负载",{"key":42,"text":296,"correct":22},"保护电源",{"key":282,"text":298,"correct":22},"保护设备","AB",{"id":301,"libraryId":5,"type":257,"typeLabel":258,"stem":302,"options":303,"answer":314,"analysis":30},942828,"熔断器的主要型式有( )。",[304,306,308,310,312],{"key":20,"text":305,"correct":26},"RT型熔断器",{"key":24,"text":307,"correct":26},"RM熔断器型",{"key":28,"text":309,"correct":26},"RL型熔断器",{"key":42,"text":311,"correct":26},"RC型熔断器",{"key":282,"text":313,"correct":22},"RD型熔断器","ABCD",{"id":316,"libraryId":5,"type":257,"typeLabel":258,"stem":317,"options":318,"answer":329,"analysis":30},942829,"低压空气断路器又称自动空气开关，是用于当电路中发 生( )等故障时，能自动分断电路的电器。",[319,321,323,325,327],{"key":20,"text":320,"correct":26},"短路",{"key":24,"text":322,"correct":26},"过载",{"key":28,"text":324,"correct":26},"欠电压",{"key":42,"text":326,"correct":22},"限位",{"key":282,"text":328,"correct":22},"触电","ABC",{"id":331,"libraryId":5,"type":257,"typeLabel":258,"stem":332,"options":333,"answer":344,"analysis":30},942830,"互感器分为( )两大类。",[334,336,338,340,342],{"key":20,"text":335,"correct":22},"测速互感器",{"key":24,"text":337,"correct":22},"功率互感器",{"key":28,"text":339,"correct":22},"温度互感器",{"key":42,"text":341,"correct":26},"电压互感器",{"key":282,"text":343,"correct":26},"电流互感器","DE",{"id":346,"libraryId":5,"type":257,"typeLabel":258,"stem":347,"options":348,"answer":329,"analysis":30},942831,"电力系统的中性点是指发电机或变压器的中性点，通常 采用( )。",[349,351,353,355,357],{"key":20,"text":350,"correct":26},"中性点不接地系统",{"key":24,"text":352,"correct":26},"中性点经消弧线圈接地",{"key":28,"text":354,"correct":26},"中性点直接接地",{"key":42,"text":356,"correct":22},"中性点三角形接地",{"key":282,"text":358,"correct":22},"中性点星形接地",{"id":360,"libraryId":5,"type":257,"typeLabel":258,"stem":361,"options":362,"answer":373,"analysis":30},942832,"PE 线所用材质与相线、工作零线相同，其最小截面应符 合( )。",[363,365,367,369,371],{"key":20,"text":364,"correct":22},"相线芯线截面S≤10mm² PE线最小截面为Smm²",{"key":24,"text":366,"correct":26},"相线芯线截面S≤160mm² PE线最小截面为Smm²",{"key":28,"text":368,"correct":26},"相线芯线截面16mm2\u003CS≤35mm² PE线最小截面为S=16mm²",{"key":42,"text":370,"correct":26},"相线芯线截面S>35mm² PE线最小截面为S\u002F2",{"key":282,"text":372,"correct":22},"相线芯线截面S>70mm² PE线最小截面为S\u002F3","BCD",{"id":375,"libraryId":5,"type":257,"typeLabel":258,"stem":376,"options":377,"answer":388,"analysis":30},942833,"在供电系统中相线、N 线、PE 线的颜色标记必须符合以下规定( )任何情况下上述颜色标记严禁混用和互相代用。",[378,380,382,384,386],{"key":20,"text":379,"correct":26},"相线Ll(A)、L2(B)、L3(C)相序的绝缘颜色依次为黄、绿、红色",{"key":24,"text":381,"correct":22},"相线Ll(A)、L2(B)、L3(C)相序的绝缘颜色依次为红、绿、黄色",{"key":28,"text":383,"correct":26},"N线的绝缘颜色为淡蓝色",{"key":42,"text":385,"correct":22},"N线的绝缘颜色为黑色",{"key":282,"text":387,"correct":26},"PE线的绝缘颜色为绿\u002F黄双色","ACE",{"id":390,"libraryId":5,"type":257,"typeLabel":258,"stem":391,"options":392,"answer":329,"analysis":30},942834,"施工现场供电系统保护(PE 线)设置重复接地的部位是( )以及塔式起重机、施工升降机、物料提升机、混凝土搅拌站等大型施工机械设备开关箱处。",[393,395,397,399,401],{"key":20,"text":394,"correct":26},"总配电箱(配电柜)处",{"key":24,"text":396,"correct":26},"各分路分配电箱处",{"key":28,"text":398,"correct":26},"各分路最远端用电设备开关箱",{"key":42,"text":400,"correct":22},"用电设备处",{"key":282,"text":402,"correct":22},"用电设备金属物",{"id":404,"libraryId":5,"type":257,"typeLabel":258,"stem":405,"options":406,"answer":388,"analysis":30},942835,"在不同的电力系统中，对各种接地电阻的数值有不同的 要求。在建筑施工现场临时用电系统中，各种接地电阻的 数值的要求是( )。",[407,409,411,413,415],{"key":20,"text":408,"correct":26},"工作接地电阻阻值不得大于4Ω",{"key":24,"text":410,"correct":22},"工作接地电阻阻值不得大于10Ω",{"key":28,"text":412,"correct":26},"重复接地电阻阻值不得大于10Ω",{"key":42,"text":414,"correct":22},"防雷或冲击接地电阻阻值不得大于5Ω",{"key":282,"text":416,"correct":26},"防雷或冲击接地电阻阻值不得大于30Ω",{"id":418,"libraryId":5,"type":257,"typeLabel":258,"stem":419,"options":420,"answer":314,"analysis":30},942836,"建筑施工现场的接地主要有四种类别，即( )。",[421,423,424,426,428],{"key":20,"text":422,"correct":26},"工作接地",{"key":24,"text":189,"correct":26},{"key":28,"text":425,"correct":26},"重复接地",{"key":42,"text":427,"correct":26},"防雷接地",{"key":282,"text":429,"correct":22},"防触电接地",{"id":431,"libraryId":5,"type":257,"typeLabel":258,"stem":432,"options":433,"answer":329,"analysis":30},942837,"用作人工接地体的金属材料通常可以采用( )及其焊接件。",[434,436,438,440,442],{"key":20,"text":435,"correct":26},"圆钢",{"key":24,"text":437,"correct":26},"钢管",{"key":28,"text":439,"correct":26},"角钢",{"key":42,"text":441,"correct":22},"螺纹钢",{"key":282,"text":443,"correct":22},"铝材",{"id":445,"libraryId":5,"type":257,"typeLabel":258,"stem":446,"options":447,"answer":388,"analysis":30},942838,"供电系统电能质量的优劣可以由( )和供电的可靠性等指标来衡量。",[448,450,452,454,456],{"key":20,"text":449,"correct":26},"电压",{"key":24,"text":451,"correct":22},"电流",{"key":28,"text":453,"correct":26},"频率",{"key":42,"text":455,"correct":22},"功率",{"key":282,"text":457,"correct":26},"波形",{"id":459,"libraryId":5,"type":257,"typeLabel":258,"stem":460,"options":461,"answer":329,"analysis":30},942839,"重复接地的作用是( )。",[462,464,466,468,470],{"key":20,"text":463,"correct":26},"降低故障点对地的电压",{"key":24,"text":465,"correct":26},"减轻保护零线断线的危险性",{"key":28,"text":467,"correct":26},"缩短故障持续时间",{"key":42,"text":469,"correct":22},"保证正常电压",{"key":282,"text":471,"correct":22},"减少触电机率",{"id":473,"libraryId":5,"type":257,"typeLabel":258,"stem":474,"options":475,"answer":299,"analysis":30},942840,"配电室的照明应包括( )两个彼此独立的照明系统。",[476,478,480,482,484],{"key":20,"text":477,"correct":26},"正常照明",{"key":24,"text":479,"correct":26},"事故照明",{"key":28,"text":481,"correct":22},"局部照明",{"key":42,"text":483,"correct":22},"值班照明",{"key":282,"text":485,"correct":22},"混合照明",{"id":487,"libraryId":5,"type":257,"typeLabel":258,"stem":488,"options":489,"answer":373,"analysis":30},942841,"配电室内的配电柜布置的位置要求是( )。",[490,492,494,496,498],{"key":20,"text":491,"correct":22},"配电柜正面的操作单列布置道通宽度时不小于1米",{"key":24,"text":493,"correct":26},"配电柜正面的操作单列布置道通宽度时不小于1.5米",{"key":28,"text":495,"correct":26},"配电柜正面的操作面对面双通道布置时宽度不小于2米",{"key":42,"text":497,"correct":26},"配电柜后面的单列布置维护道通宽度时不小于0.8米",{"key":282,"text":499,"correct":22},"配电柜后面的单列布置维护道通宽度时不小于1米",{"id":501,"libraryId":5,"type":257,"typeLabel":258,"stem":502,"options":503,"answer":514,"analysis":30},942842,"配电线路的形式可分为( )。",[504,506,508,510,512],{"key":20,"text":505,"correct":26},"放射式配线",{"key":24,"text":507,"correct":26},"树干式配线",{"key":28,"text":509,"correct":26},"链式配线",{"key":42,"text":511,"correct":22},"分支式配线",{"key":282,"text":513,"correct":26},"环形配线","ABCE",{"id":516,"libraryId":5,"type":257,"typeLabel":258,"stem":517,"options":518,"answer":268,"analysis":30},942843,"架空线路中的电杆可采用( )。",[519,521,523,525,527],{"key":20,"text":520,"correct":26},"木杆",{"key":24,"text":522,"correct":22},"树木",{"key":28,"text":524,"correct":26},"钢筋混凝土杆",{"key":42,"text":526,"correct":22},"铁架",{"key":282,"text":528,"correct":22},"脚手架作电杆",{"id":530,"libraryId":5,"type":257,"typeLabel":258,"stem":531,"options":532,"answer":543,"analysis":30},942844,"建筑工地临时用电缆在采用直埋时应注意的是( )。",[533,535,537,539,541],{"key":20,"text":534,"correct":26},"电缆直埋时，应开挖深度为不小于0.7米的断面为梯形的沟槽。",{"key":24,"text":536,"correct":22},"电缆直埋时，应开挖深度为不小于1米的断面为梯形的沟槽。",{"key":28,"text":538,"correct":26},"在电缆紧邻上、下、左、右侧均匀附设不小于50mm厚的细砂",{"key":42,"text":540,"correct":26},"在地表面覆盖砖或混凝土板",{"key":282,"text":542,"correct":22},"在地表面敷设保护管","ACD",{"id":545,"libraryId":5,"type":257,"typeLabel":258,"stem":546,"options":547,"answer":543,"analysis":30},942845,"室内",[548,550,552,554,556],{"key":20,"text":549,"correct":26},"暗敷设线路部分不得有接头",{"key":24,"text":551,"correct":22},"暗敷设线路部分在可以维护场所允许有接头，但在两根导线的接头要错开",{"key":28,"text":553,"correct":26},"暗敷设金属穿管应做等电位连接，并与PE线相连接",{"key":42,"text":555,"correct":26},"潮湿场所或埋地非电缆(绝缘导线)配线必须穿管敷设",{"key":282,"text":557,"correct":22},"在混凝土内暗敷设导线，允许不穿管直接敷设",{"id":559,"libraryId":5,"type":257,"typeLabel":258,"stem":560,"options":561,"answer":388,"analysis":30},942846,"导线与电气设备的电接触和机械性能，除( )能直接与电器设备连接外，大于上述规格的多股或单股芯，通常都应在线头上焊接或压接接线端子。",[562,564,566,568,570],{"key":20,"text":563,"correct":26},"10mm²以下的单股铜芯线",{"key":24,"text":565,"correct":22},"4mm²以下的单股铜芯线",{"key":28,"text":567,"correct":26},"2.5mm²及以下的多股铜芯线",{"key":42,"text":569,"correct":22},"10mm²及以下的多股铜芯线",{"key":282,"text":571,"correct":26},"2.5mm²及以下的单股铝芯线",{"id":573,"libraryId":5,"type":257,"typeLabel":258,"stem":574,"options":575,"answer":586,"analysis":30},942847,"手动开关电器只许用于直接控制( )电路。",[576,578,580,582,584],{"key":20,"text":577,"correct":22},"小容量动力电路(5.5kW以下)",{"key":24,"text":579,"correct":26},"3kW动力电路(以下)",{"key":28,"text":581,"correct":22},"小容量动力电路(1kW以下)",{"key":42,"text":583,"correct":22},"单一电动机",{"key":282,"text":585,"correct":26},"照明电路","BE",{"id":588,"libraryId":5,"type":257,"typeLabel":258,"stem":589,"options":590,"answer":601,"analysis":30},942848,"配电室的位置应靠近电源；靠近负荷中心外；周围环境 灰尘少、潮气少、震动少，无腐蚀介质、无易燃易爆物、 无积水；还应( )。",[591,593,595,597,599],{"key":20,"text":592,"correct":26},"进出线方便",{"key":24,"text":594,"correct":26},"周边道路畅通",{"key":28,"text":596,"correct":22},"避开污染源的上风侧",{"key":42,"text":598,"correct":22},"避开易积水场所的正上方",{"key":282,"text":600,"correct":26},"避开污染源的下风侧和易积水场所的正下方","ABE",{"id":603,"libraryId":5,"type":257,"typeLabel":258,"stem":604,"options":605,"answer":514,"analysis":30},942849,"导线截面的选择有( )。",[606,608,610,612,614],{"key":20,"text":607,"correct":26},"按允许温升初选导线截面",{"key":24,"text":609,"correct":26},"按电压偏移校验导线截面",{"key":28,"text":611,"correct":26},"按机械强度校验导线截面",{"key":42,"text":613,"correct":22},"绝缘强度",{"key":282,"text":615,"correct":26},"按线路工作制核准导线截面",{"id":617,"libraryId":5,"type":257,"typeLabel":258,"stem":618,"options":619,"answer":284,"analysis":30},942850,"总配电箱的电器应具备( )。",[620,622,624,626,628],{"key":20,"text":621,"correct":26},"电源隔离",{"key":24,"text":623,"correct":26},"正常接通与分断电路",{"key":28,"text":625,"correct":26},"短路保护功能",{"key":42,"text":627,"correct":26},"过载保护功能",{"key":282,"text":629,"correct":26},"漏电保护功能",{"id":631,"libraryId":5,"type":257,"typeLabel":258,"stem":632,"options":633,"answer":314,"analysis":30},942851,"轨道式塔式起重机的防雷接地可以籍助于机轮和轨道 的连接，但应附加以下措施( )。",[634,636,638,640,642],{"key":20,"text":635,"correct":26},"轨道两端各设一组接地装置",{"key":24,"text":637,"correct":26},"较长轨道每隔30m加一组接地装置",{"key":28,"text":639,"correct":26},"轨道的接头处作电气连接",{"key":42,"text":641,"correct":26},"两轨道端部作环形电气连接",{"key":282,"text":643,"correct":22},"轨道式塔式起重机与零线连接",{"id":645,"libraryId":5,"type":257,"typeLabel":258,"stem":646,"options":647,"answer":658,"analysis":30},942852,"手持式电动工具绝缘电阻限值要求是( )。",[648,650,652,654,656],{"key":20,"text":649,"correct":22},"Ⅰ类绝缘电阻大于等于0.5MΩ",{"key":24,"text":651,"correct":26},"Ⅰ类绝缘电阻大于等于2MΩ",{"key":28,"text":653,"correct":22},"Ⅱ类绝缘电阻大于等于1MΩ",{"key":42,"text":655,"correct":26},"Ⅱ类绝缘电阻大于等于7MΩ",{"key":282,"text":657,"correct":26},"Ⅲ类绝缘电阻大于等于1MΩ","BDE",[660,663,666,669,672,675],{"id":15,"name":661,"category":7,"favorite":662},"领导干部任职前廉政法规知识测试题",92,{"id":664,"name":665,"category":7,"favorite":15},595,"建筑结构与设备",{"id":667,"name":668,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":670,"name":671,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":673,"name":674,"category":7,"favorite":8},534,"BIM工程师",{"id":676,"name":674,"category":7,"favorite":8},535]