[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-666-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":548},{"id":5,"name":6,"category":7,"favorite":8},666,"建筑电工","建筑工程",0,2,50,1106,[13,34,46,58,70,81,93,103,113,123,133,143,153,163,173,183,193,203,213,223,233,243,251,261,271,281,291,301,311,321,333,344,352,364,376,388,400,409,421,432,444,456,465,477,489,501,509,517,526,536],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},942452,1,"单选题","漏电保护器按防溅要求,外壳防护等级必须符合规定,也就是说必须能通过10min的淋雨试验,淋雨试验后还要能承受( )耐压试验,各项动作特性仍能符合要求。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","500V",false,{"key":24,"text":25,"correct":22},"B","800V",{"key":27,"text":28,"correct":29},"C","1000V",true,{"key":31,"text":32,"correct":22},"D","1500V","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},942453,"高大建筑机械设备上的接闪器长度应为( )。",[38,40,42,44],{"key":20,"text":39,"correct":22},"1—1.5m",{"key":24,"text":41,"correct":29},"1—2m",{"key":27,"text":43,"correct":22},"1.5—2m",{"key":31,"text":45,"correct":22},"3m以上",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},942454,"电杆埋深宜为杆长( )且应将回填土分层夯实。",[50,52,54,56],{"key":20,"text":51,"correct":22},"1\u002F5加0.2m",{"key":24,"text":53,"correct":22},"1\u002F8加0.4m",{"key":27,"text":55,"correct":29},"1\u002F10加0.6m",{"key":31,"text":57,"correct":22},"1\u002F12加0.8m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},942455,"配电室内的裸母线与地面通道的垂直距离不小于( )。",[62,64,66,68],{"key":20,"text":63,"correct":22},"2m",{"key":24,"text":65,"correct":29},"2.5m",{"key":27,"text":67,"correct":22},"3m",{"key":31,"text":69,"correct":22},"3.5m",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},942456,"根据配电室的布署要求,配电柜侧面的维护通道宽度不小于( )。",[74,76,78,80],{"key":20,"text":75,"correct":22},"0.5m",{"key":24,"text":77,"correct":29},"1m",{"key":27,"text":79,"correct":22},"1.5m",{"key":31,"text":63,"correct":22},{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":31,"analysis":33},942457,"按照《施工现场临时用电安全技术规范》JGJ46—2005的规定,施工现场临时用电设备在( )台及以上,或设备容量在50KW及以上者,应编制组织设计。临时用电组织设计变更时,必须履行“编制.审核.批准”程序,由电气工程技术人员组织编制,经相关部门审核及具有法人资格企业的技术负责人批准后实施。",[85,87,89,91],{"key":20,"text":86,"correct":22},"1",{"key":24,"text":88,"correct":22},"2",{"key":27,"text":90,"correct":22},"3",{"key":31,"text":92,"correct":29},"5",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":20,"analysis":33},942458,"在进行电子底板贴焊、剪脚等工序时应( )。",[97,99,101],{"key":20,"text":98,"correct":29},"戴上防护眼镜",{"key":24,"text":100,"correct":22},"戴上护耳器",{"key":27,"text":102,"correct":22},"戴上安全帽",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":24,"analysis":33},942459,"使用的电气设备按有关安全规程,其外壳应有什么防护措施?( )。",[107,109,111],{"key":20,"text":108,"correct":22},"无",{"key":24,"text":110,"correct":29},"保护性接零或接地",{"key":27,"text":112,"correct":22},"防锈漆",{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":115,"options":116,"answer":27,"analysis":33},942460,"任何电气设备在未验明无电之前,一律怎样( )认为。",[117,119,121],{"key":20,"text":118,"correct":22},"无电",{"key":24,"text":120,"correct":22},"也许有电",{"key":27,"text":122,"correct":29},"有电",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":27,"analysis":33},942461,"扑救电气设备火灾时,不能用什么灭火器?( )。",[127,129,131],{"key":20,"text":128,"correct":22},"四氯化碳灭火器",{"key":24,"text":130,"correct":22},"二氧化碳灭火器",{"key":27,"text":132,"correct":29},"泡沫灭火器",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":20,"analysis":33},942462,"车间内的明、暗插座距地面的高度一般不低于( )多少米?",[137,139,141],{"key":20,"text":138,"correct":29},"0.3米",{"key":24,"text":140,"correct":22},"0.2米",{"key":27,"text":142,"correct":22},"0.1米",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":24,"analysis":33},942463,"雷电放电具有( )的特点。",[147,149,151],{"key":20,"text":148,"correct":22},"电流大、电压高",{"key":24,"text":150,"correct":29},"电流小、电压高",{"key":27,"text":152,"correct":22},"电流大、电压低",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":27,"analysis":33},942464,"人体在电磁场作用下,由于( )将使人体受到不同程度的伤害",[157,159,161],{"key":20,"text":158,"correct":22},"电流",{"key":24,"text":160,"correct":22},"电压",{"key":27,"text":162,"correct":29},"电磁波辐射",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":20,"analysis":33},942465,"下列有关使用漏电保护器的说法，哪种正确？",[167,169,171],{"key":20,"text":168,"correct":29},"漏电保护器既可用来保护人身安全,还可用来对低压系统或设备的对地绝缘状况起到监督作用。",{"key":24,"text":170,"correct":22},"漏电保护器安装点以后的线路不可对地绝缘。",{"key":27,"text":172,"correct":22},"漏电保护器在日常使用中不可在通电状态下按动实验按钮来检验其是否灵敏可靠。",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":27,"analysis":33},942466,"检修高压电动机时。下列哪种行为错误？",[177,179,181],{"key":20,"text":178,"correct":22},"先实施停电安全措施,再在高压电动机及其附属装置的回路上进行检修工作。",{"key":24,"text":180,"correct":22},"检修工作终结,需通电实验高压电动机及其启动装置时,先让全部工作人员撤离现场,再送电试运转。",{"key":27,"text":182,"correct":29},"在运行的高压电动机的接地线上进行检修工作。",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":27,"analysis":33},942467,"民用照明电路电压是以下哪种？",[187,189,191],{"key":20,"text":188,"correct":22},"直流电压220伏",{"key":24,"text":190,"correct":22},"交流电压280伏",{"key":27,"text":192,"correct":29},"交流电压220伏",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":27,"analysis":33},942468,"工厂内各固定电线插座损坏时,将会引起( )",[197,199,201],{"key":20,"text":198,"correct":22},"引起工作不方便",{"key":24,"text":200,"correct":22},"不美观",{"key":27,"text":202,"correct":29},"触电伤害",{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":27,"analysis":33},942469,"发生触电事故的危险电压一般是从( )伏开始。",[207,209,211],{"key":20,"text":208,"correct":22},"24",{"key":24,"text":210,"correct":22},"26",{"key":27,"text":212,"correct":29},"65",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":24,"analysis":33},942470,"使用手持电动工具时,下列注意事项哪个正确？",[217,219,221],{"key":20,"text":218,"correct":22},"使用万能插座",{"key":24,"text":220,"correct":29},"使用漏电保护器",{"key":27,"text":222,"correct":22},"身体或衣服潮湿",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":24,"analysis":33},942471,"在遇到高压电线断落地面时,导线断落点米内,禁止人员进入( )。",[227,229,231],{"key":20,"text":228,"correct":22},"10",{"key":24,"text":230,"correct":29},"20",{"key":27,"text":232,"correct":22},"30",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":20,"analysis":33},942472,"金属梯子不适于以下什么工作场所?( )。",[237,239,241],{"key":20,"text":238,"correct":29},"有触电机会的工作场所",{"key":24,"text":240,"correct":22},"坑穴或密闭场所",{"key":27,"text":242,"correct":22},"高空作业",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":20,"analysis":33},942473,"下列( )灭火器适于扑灭电气火灾。",[247,248,250],{"key":20,"text":130,"correct":29},{"key":24,"text":249,"correct":22},"干粉灭火器",{"key":27,"text":132,"correct":22},{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":27,"analysis":33},942474,"长期在高频电磁场作用下,操作者会有( )不良反应。",[255,257,259],{"key":20,"text":256,"correct":22},"呼吸困难",{"key":24,"text":258,"correct":22},"神经失常",{"key":27,"text":260,"correct":29},"疲劳无力",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},942475,"静电电压最高可达( ),可现场放电,产生静电火花,引起火灾。",[265,267,269],{"key":20,"text":266,"correct":22},"50伏",{"key":24,"text":268,"correct":29},"数万伏",{"key":27,"text":270,"correct":22},"220伏",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":27,"analysis":33},942476,"电器着火时下列不能用的灭火方法是哪种?( )。",[275,277,279],{"key":20,"text":276,"correct":22},"用四氯化碳或1211灭火器进行灭火",{"key":24,"text":278,"correct":22},"用沙土灭火",{"key":27,"text":280,"correct":29},"用水灭火",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":33},942477,"触电事故中,绝大部分是( )导致人身伤亡的。",[285,287,289],{"key":20,"text":286,"correct":29},"人体接受电流遭到电击",{"key":24,"text":288,"correct":22},"烧伤",{"key":27,"text":290,"correct":22},"电休克",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":27,"analysis":33},942478,"停电检修时,在一经合闸即可送电到工作地点的开关或刀闸的操作把手上,应悬挂如下哪种标示牌？",[295,297,299],{"key":20,"text":296,"correct":22},"在此工作",{"key":24,"text":298,"correct":22},"“止步,高压危险”",{"key":27,"text":300,"correct":29},"“禁止合闸,有人工作”",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":33},942479,"三线电缆中的红线代表( )。",[305,307,309],{"key":20,"text":306,"correct":22},"零线",{"key":24,"text":308,"correct":29},"火线",{"key":27,"text":310,"correct":22},"地线",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":24,"analysis":33},942480,"在工作环境中见到以下标志,表示( )。",[315,317,319],{"key":20,"text":316,"correct":22},"注意安全",{"key":24,"text":318,"correct":29},"当心触电",{"key":27,"text":320,"correct":22},"当心感染",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":20,"analysis":33},942481,"热继电器是一种( )保护电气元件。",[325,327,329,331],{"key":20,"text":326,"correct":29},"过载",{"key":24,"text":328,"correct":22},"短路",{"key":27,"text":330,"correct":22},"触电",{"key":31,"text":332,"correct":22},"欠压",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":20,"analysis":33},942482,"可能受到雨水影响的露天、潮湿或充满蒸汽的场所，必 须使用防溅型额定漏电动作电流不大于( )mA，额定漏电动 作时间不大于 0.1s 的漏电保护器。",[337,339,341,342],{"key":20,"text":338,"correct":29},"15",{"key":24,"text":340,"correct":22},"25",{"key":27,"text":232,"correct":22},{"key":31,"text":343,"correct":22},"50",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":27,"analysis":33},942483,"一般场所，即室内的干燥场所必须使用额定漏电动作电 流不大于( )mA，额定漏电动作时间应不大于 0.1s 的漏电 保护器。",[348,349,350,351],{"key":20,"text":338,"correct":22},{"key":24,"text":340,"correct":22},{"key":27,"text":232,"correct":29},{"key":31,"text":343,"correct":22},{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":27,"analysis":33},942484,"漏电保护器投入使用后，在使用过程中须( )检验一次， 以保证其能安全可靠地运行。",[356,358,360,362],{"key":20,"text":357,"correct":22},"每天",{"key":24,"text":359,"correct":22},"每星期",{"key":27,"text":361,"correct":29},"每月",{"key":31,"text":363,"correct":22},"每年",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":20,"analysis":33},942485,"确定电动机是否受潮，可用兆欧表测量各相之间和各相 与外壳之间的绝缘电阻，一般不应低于( )。",[368,370,372,374],{"key":20,"text":369,"correct":29},"0.5MΩ",{"key":24,"text":371,"correct":22},"1MΩ",{"key":27,"text":373,"correct":22},"2MΩ",{"key":31,"text":375,"correct":22},"7MΩ",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":27,"analysis":33},942486,"施工现场供配电系统保护零线(PE 线)的重复接地数量 不少于( )。",[380,382,384,386],{"key":20,"text":381,"correct":22},"一处",{"key":24,"text":383,"correct":22},"二处",{"key":27,"text":385,"correct":29},"三处",{"key":31,"text":387,"correct":22},"四处",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":31,"analysis":33},942487,"在建筑施工现场临时用电系统中，重复接地(工频)电阻值一般不得大于( )。",[392,394,396,398],{"key":20,"text":393,"correct":22},"1Ω",{"key":24,"text":395,"correct":22},"4Ω",{"key":27,"text":397,"correct":22},"5Ω",{"key":31,"text":399,"correct":29},"10Ω",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":31,"analysis":33},942488,"在建筑施工现场临时用电系统中，即防雷接地或冲击接地电阻值不得大于( )。",[404,405,406,407],{"key":20,"text":393,"correct":22},{"key":24,"text":395,"correct":22},{"key":27,"text":399,"correct":22},{"key":31,"text":408,"correct":29},"30Ω",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":27,"analysis":33},942489,"在中性点直接接地的电力系统中，为了保证接地的作用 和效果，除在中性点处直接接地外，还须在保护零线上的 一处或多处再作接地，称为( )。",[413,415,417,419],{"key":20,"text":414,"correct":22},"工作接地",{"key":24,"text":416,"correct":22},"保护接地",{"key":27,"text":418,"correct":29},"重复接地",{"key":31,"text":420,"correct":22},"防雷接地",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},942490,"变压器中性点直接接地，与变压器直接接地的中性点连 接的导线，称为( )。",[425,426,428,430],{"key":20,"text":306,"correct":29},{"key":24,"text":427,"correct":22},"中性线",{"key":27,"text":429,"correct":22},"保护线",{"key":31,"text":431,"correct":22},"接地线",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":20,"analysis":33},942491,"在供电系统中相线、N 线、PE 线的颜色标记必须符合以 下规定：相线 Ll(A)、L2(B)、L3(C)相序的绝缘颜色依次 为( )；任何情况下上述颜色标记严禁混用和互相代用。",[436,438,440,442],{"key":20,"text":437,"correct":29},"黄、绿、红色",{"key":24,"text":439,"correct":22},"红、绿、黄色",{"key":27,"text":441,"correct":22},"红、黄、绿色",{"key":31,"text":443,"correct":22},"红、绿、蓝色",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":24,"analysis":33},942492,"接地线连接处应采用搭接焊。其中扁钢的搭接长度应为 其宽度的( )倍；圆钢的搭接长应为其直径的6倍。",[448,450,452,454],{"key":20,"text":449,"correct":22},"1倍",{"key":24,"text":451,"correct":29},"2倍",{"key":27,"text":453,"correct":22},"4倍",{"key":31,"text":455,"correct":22},"5倍",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":31,"analysis":33},942493,"接地线连接处应采用搭接焊。其中扁钢的搭接长度应为 其宽度的 2 倍；圆钢的搭接长应为其直径的( )。",[460,461,462,463],{"key":20,"text":449,"correct":22},{"key":24,"text":451,"correct":22},{"key":27,"text":455,"correct":22},{"key":31,"text":464,"correct":29},"6倍",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":20,"analysis":33},942494,"接地体各部分接地极间及接地体与接地线的连接均应 采用( )。",[469,471,473,475],{"key":20,"text":470,"correct":29},"焊接",{"key":24,"text":472,"correct":22},"压接",{"key":27,"text":474,"correct":22},"螺栓连接",{"key":31,"text":476,"correct":22},"插接",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":27,"analysis":33},942495,"每一组接地装置的接地线应采用两根及以上导体。且两接地体相互间距不宜小于( )。",[481,483,485,487],{"key":20,"text":482,"correct":22},"1.5米",{"key":24,"text":484,"correct":22},"2.5米",{"key":27,"text":486,"correct":29},"5米",{"key":31,"text":488,"correct":22},"8米",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":20,"analysis":33},942496,"在供电系统中规定：相线 Ll(A)相序绝缘颜色为( )。",[493,495,497,499],{"key":20,"text":494,"correct":29},"黄色",{"key":24,"text":496,"correct":22},"绿色",{"key":27,"text":498,"correct":22},"红色",{"key":31,"text":500,"correct":22},"蓝色",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":24,"analysis":33},942497,"在供电系统中规定：相线 L2(B)相序绝缘颜色为( )。",[505,506,507,508],{"key":20,"text":494,"correct":22},{"key":24,"text":496,"correct":29},{"key":27,"text":498,"correct":22},{"key":31,"text":500,"correct":22},{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":27,"analysis":33},942498,"在供电系统中规定：相线 L3(C)相序绝缘颜色为( )。",[513,514,515,516],{"key":20,"text":494,"correct":22},{"key":24,"text":496,"correct":22},{"key":27,"text":498,"correct":29},{"key":31,"text":500,"correct":22},{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":31,"analysis":33},942499,"在供电系统中规定：零线 N 绝缘颜色为( )。",[521,522,523,524],{"key":20,"text":494,"correct":22},{"key":24,"text":496,"correct":22},{"key":27,"text":498,"correct":22},{"key":31,"text":525,"correct":29},"淡蓝色",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":31,"analysis":33},942500,"在供电系统中规定：PE 线(保护线)绝缘颜色为( )。",[530,531,532,534],{"key":20,"text":494,"correct":22},{"key":24,"text":496,"correct":22},{"key":27,"text":533,"correct":22},"红\u002F黄双色",{"key":31,"text":535,"correct":29},"绿\u002F黄双色",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":31,"analysis":33},942501,"建筑施工现场临时用电工程专用的电源中性点直接接 地的 220\u002F380V 三相四线制低压电力系统，必须采用( )系统。",[540,542,544,546],{"key":20,"text":541,"correct":22},"IT系统",{"key":24,"text":543,"correct":22},"TT系统",{"key":27,"text":545,"correct":22},"TN系统",{"key":31,"text":547,"correct":29},"TN-S系统",[549,552,555,558,561,564],{"id":15,"name":550,"category":7,"favorite":551},"领导干部任职前廉政法规知识测试题",92,{"id":553,"name":554,"category":7,"favorite":15},595,"建筑结构与设备",{"id":556,"name":557,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":559,"name":560,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":562,"name":563,"category":7,"favorite":8},534,"BIM工程师",{"id":565,"name":563,"category":7,"favorite":8},535]