[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-666-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":631},{"id":5,"name":6,"category":7,"favorite":8},666,"建筑电工","建筑工程",0,12,50,1106,[13,32,43,53,67,83,94,107,117,129,142,154,169,183,197,209,221,233,248,262,272,281,291,301,313,328,338,348,358,373,386,396,408,419,431,443,457,467,480,494,508,520,533,547,559,569,581,595,609,621],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":31},942953,2,"多选题","关于配电箱和开关箱的位置,下列说法哪种正确( )",[19,23,26],{"key":20,"text":21,"correct":22},"A","总配电箱应设在靠近电源的地方",true,{"key":24,"text":25,"correct":22},"B","分配电箱应设在用电设备集中的地方",{"key":27,"text":28,"correct":29},"C","分配电箱与开关箱的距离不得超过20m",false,"AB","",{"id":33,"libraryId":5,"type":15,"typeLabel":16,"stem":34,"options":35,"answer":42,"analysis":31},942955,"关于焊接机械的安全用电事项,下列说法不正确的是( )",[36,38,40],{"key":20,"text":37,"correct":29},"交流电焊机的二次线长度不应大于30米",{"key":24,"text":39,"correct":22},"交流焊接机械不必配装防二次侧触电保护器",{"key":27,"text":41,"correct":22},"交流弧焊机的二次线不必采用防水橡皮护套铜芯软电缆","BC",{"id":44,"libraryId":5,"type":15,"typeLabel":16,"stem":45,"options":46,"answer":30,"analysis":31},942956,"关于物料提升机的安全用电事项,哪种说法不正确( )",[47,49,51],{"key":20,"text":48,"correct":22},"物料提升机是只运送物料,有时可载人的垂直运输机械",{"key":24,"text":50,"correct":22},"物料提升机本身自带控制器,不必设置专用开关箱",{"key":27,"text":52,"correct":29},"物料提升机电动机正反转应籍助于接触器用按钮控制",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":66,"analysis":31},942957,"用电技术交底的文字资料必须明确记录交底的( )。",[57,59,61,63],{"key":20,"text":58,"correct":22},"日期、时间",{"key":24,"text":60,"correct":22},"交底地点",{"key":27,"text":62,"correct":22},"交底人签字",{"key":64,"text":65,"correct":22},"D","被交底人签字","ABCD",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":82,"analysis":31},942958,"配电系统中漏电保护器的设置位置应是( )。",[71,73,75,77,79],{"key":20,"text":72,"correct":29},"总配电箱总路、分配电箱总路",{"key":24,"text":74,"correct":29},"分配电箱总路、开关箱",{"key":27,"text":76,"correct":22},"总配电箱总路、开关箱",{"key":64,"text":78,"correct":22},"总配电箱各分路、开关箱",{"key":80,"text":81,"correct":29},"E","分配电箱各分路、开关箱","CD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":93,"analysis":31},942959,"关于外用电梯和物料提升机的安全用电事项,哪种说法正确( )",[87,89,91],{"key":20,"text":88,"correct":22},"每日工作前必须对行程开关、紧急停止开关、驱动机和制动器进行空载检查",{"key":24,"text":90,"correct":29},"外用电梯笼内应安装紧急停止开关,梯笼外不得安装紧急停止开关",{"key":27,"text":92,"correct":22},"上、下极限位置应设置限位开关","AC",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":106,"analysis":31},942960,"配电室位置应符合下列要求( )",[98,100,102,104],{"key":20,"text":99,"correct":29},"配电室应远离电源",{"key":24,"text":101,"correct":22},"配电室应靠近负荷中心",{"key":27,"text":103,"correct":22},"配电室应进、出线方便",{"key":64,"text":105,"correct":22},"配电室应避开污染源的下风侧和易积水场所的正下方","BCD",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":109,"options":110,"answer":93,"analysis":31},942961,"单人对心跳呼吸均停止的触电者采用心肺复苏法抢救时,挤压和吹气的比例不应是多少?( )",[111,113,115],{"key":20,"text":112,"correct":22},"每挤压5次吹气1次",{"key":24,"text":114,"correct":29},"每挤压15次吹气2次",{"key":27,"text":116,"correct":22},"每挤压10次吹气2次",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":66,"analysis":31},942962,"施工现场临时用电工程中,接地主要包括( )。",[121,123,125,127],{"key":20,"text":122,"correct":22},"工作接地",{"key":24,"text":124,"correct":22},"保护接地",{"key":27,"text":126,"correct":22},"重复接地",{"key":64,"text":128,"correct":22},"防雷接地",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":141,"analysis":31},942963,"按照《施工现场临时用电安全技术规范》JGJ46-2005的规定,临时用电组织设计变更时,必须履行( )程序。",[133,135,137,139],{"key":20,"text":134,"correct":22},"编制",{"key":24,"text":136,"correct":22},"审核",{"key":27,"text":138,"correct":22},"批准",{"key":64,"text":140,"correct":29},"签字","ABC",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":141,"analysis":31},942964,"兆欧表又称绝缘摇表,主要用以测量( )绝缘电阻。",[146,148,150,152],{"key":20,"text":147,"correct":22},"电机",{"key":24,"text":149,"correct":22},"电器",{"key":27,"text":151,"correct":22},"配电线路",{"key":64,"text":153,"correct":29},"机械",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":168,"analysis":31},942965,"自然接地体可利用的地下设施有(ABCE)。",[158,160,162,164,166],{"key":20,"text":159,"correct":22},"结构钢筋体",{"key":24,"text":161,"correct":22},"金属井管",{"key":27,"text":163,"correct":22},"金属水管",{"key":64,"text":165,"correct":29},"金属燃气管",{"key":80,"text":167,"correct":22},"铠装电缆的钢铠","ABCE",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":141,"analysis":31},942966,"配电箱中的刀型开关在正常情况下可用于( )。",[173,175,177,179,181],{"key":20,"text":174,"correct":22},"接通空载电路",{"key":24,"text":176,"correct":22},"分断空载电路",{"key":27,"text":178,"correct":22},"电源隔离",{"key":64,"text":180,"correct":29},"接通负载电路",{"key":80,"text":182,"correct":29},"分断负载电路",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":66,"analysis":31},942967,"保护零线必须在( )做重复接地。",[187,189,191,193,195],{"key":20,"text":188,"correct":22},"超长的配电线路的中间",{"key":24,"text":190,"correct":22},"超长的配电线路的末端处",{"key":27,"text":192,"correct":22},"总配电箱",{"key":64,"text":194,"correct":22},"配电室",{"key":80,"text":196,"correct":29},"所有设备的金属外壳",{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":66,"analysis":31},942968,"直击雷防护的主要措施( )。",[201,203,205,207],{"key":20,"text":202,"correct":22},"装设避雷针",{"key":24,"text":204,"correct":22},"装设避雷线",{"key":27,"text":206,"correct":22},"装设避雷网",{"key":64,"text":208,"correct":22},"装设避雷带",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":141,"analysis":31},942969,"供电系统分为( )。",[213,215,217,219],{"key":20,"text":214,"correct":22},"二次变压供电系统",{"key":24,"text":216,"correct":22},"一次变压供电系统",{"key":27,"text":218,"correct":22},"低压供电系统",{"key":64,"text":220,"correct":29},"高压供电系统",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":141,"analysis":31},942970,"重复接地的作用分别是( )。",[225,227,229,231],{"key":20,"text":226,"correct":22},"降低故障点对地的电压",{"key":24,"text":228,"correct":22},"减轻保护零线断线的危险性",{"key":27,"text":230,"correct":22},"缩短事故持续时间",{"key":64,"text":232,"correct":29},"加大对电器的保护",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":247,"analysis":31},942971,"行灯的电源电压可以是( )。",[237,239,241,243,245],{"key":20,"text":238,"correct":29},"220V",{"key":24,"text":240,"correct":29},"110V",{"key":27,"text":242,"correct":22},"36V",{"key":64,"text":244,"correct":22},"24V",{"key":80,"text":246,"correct":22},"12V","CDE",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":66,"analysis":31},942972,"施工现场必须设置配电室,每一个电气回路中应该合理配置( )功能。",[252,254,256,258,260],{"key":20,"text":253,"correct":22},"电气隔离",{"key":24,"text":255,"correct":22},"短路",{"key":27,"text":257,"correct":22},"过载",{"key":64,"text":259,"correct":22},"漏电保护",{"key":80,"text":261,"correct":29},"断路",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":30,"analysis":31},942973,"关于焊接机械的安全用电事项,下列说法正确的是( )",[266,268,270],{"key":20,"text":267,"correct":22},"电焊机应放置在防雨、干燥和通风良好的地方",{"key":24,"text":269,"correct":22},"交流弧焊机变压器的一次侧电源线长度不应大于500厘米",{"key":27,"text":271,"correct":29},"电焊机可采用金属构件或间接结构钢筋代替二次线的地线",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":30,"analysis":31},942974,"关于外用电梯和物料提升机的安全用电事项,哪种说法不正确( )",[276,278,279],{"key":20,"text":277,"correct":22},"每日工作前必须对行程开关、紧急停止开关、驱动机和制动器进行空载检查,每月检查一次防坠落措施",{"key":24,"text":90,"correct":22},{"key":27,"text":280,"correct":29},"梯轨上、下极限位置应设置限位开关",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":42,"analysis":31},942975,"150瓦以上的灯泡不应安装在哪两种灯头上?( )",[285,287,289],{"key":20,"text":286,"correct":29},"A、瓷灯头",{"key":24,"text":288,"correct":22},"B、胶木灯头",{"key":27,"text":290,"correct":22},"C、防水灯头",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":93,"analysis":31},942976,"使用潜水泵时,下列哪些行为属禁止?( )",[295,297,299],{"key":20,"text":296,"correct":22},"拉着电缆或出水管将泵放入水中",{"key":24,"text":298,"correct":29},"将泵放在牢固的竹箩内再放入水中",{"key":27,"text":300,"correct":22},"不切断电源把泵放入水中",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":30,"analysis":31},942977,"在电气工程中,接零主要有( )两种。",[305,307,309,311],{"key":20,"text":306,"correct":22},"工作接零",{"key":24,"text":308,"correct":22},"保护接零",{"key":27,"text":310,"correct":29},"设备接零",{"key":64,"text":312,"correct":29},"机械接零",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":327,"analysis":31},942978,"我省施工现场临时用电总体目标应当做到:在施工现场专用的中性点直接接地的电力线路中必须采用TN-S接零保护系统、( )等。",[317,319,321,323,325],{"key":20,"text":318,"correct":22},"配电箱和开关箱合格率应达到100%",{"key":24,"text":320,"correct":22},"用电设备配备应设置专用的开关箱,实行“一机一闸一漏一箱”制",{"key":27,"text":322,"correct":22},"施工现场临时用电必须编制专项施工方案",{"key":64,"text":324,"correct":22},"安装、维修或拆除临时用电工程必须由专业电工完成",{"key":80,"text":326,"correct":22},"建立安全技术档案","ABCDE",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":30,"analysis":31},942979,"关于手持式电动工具的安全使用,下列哪种说法正确( )",[332,334,336],{"key":20,"text":333,"correct":22},"手持式电动工具使用前应严格检查",{"key":24,"text":335,"correct":22},"手持式电动工具使用中出现异常现象应停止使用,并断电脱离电源后在进行检查和维修",{"key":27,"text":337,"correct":29},"携带手持电动工具时应手握手柄或手提电源线",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":141,"analysis":31},942980,"人体触电时,是危险的,请按顺序排列?( )",[342,344,346],{"key":20,"text":343,"correct":22},"胸部至左手",{"key":24,"text":345,"correct":22},"左脚至右脚",{"key":27,"text":347,"correct":22},"右手至左手",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":30,"analysis":31},942981,"以下哪种电气线路故障可能会引发火灾?( )",[352,354,356],{"key":20,"text":353,"correct":22},"绝缘损坏造成短路",{"key":24,"text":355,"correct":22},"接触不良",{"key":27,"text":357,"correct":29},"断电",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":372,"analysis":31},942982,"施工现场一般选用额定电压为220v的照明器,对( ),必须使用相应等级的安全电压照明器、照明灯具。",[362,364,366,368,370],{"key":20,"text":363,"correct":22},"隧道工程",{"key":24,"text":365,"correct":22},"人防工程",{"key":27,"text":367,"correct":29},"孔桩工程",{"key":64,"text":369,"correct":22},"易触及带电体场所",{"key":80,"text":371,"correct":22},"潮湿场所","ABDE",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":385,"analysis":31},942983,"关于手持式电动工具的漏电保护器,下列说法哪一种是正确的( )。",[377,379,381,383],{"key":20,"text":378,"correct":22},"应遵守“一机一漏”制",{"key":24,"text":380,"correct":22},"参数选择应符合使用于潮湿或有腐蚀介质场所的要求",{"key":27,"text":382,"correct":29},"额定漏电动作电流应大于30mA",{"key":64,"text":384,"correct":22},"额定漏电动作时间不应大于0","ABD",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":30,"analysis":31},942984,"关于配电箱、开关箱的安全使用,下列哪种说法正确( )",[390,392,394],{"key":20,"text":391,"correct":22},"配电箱、开关箱内不得随意挂接其他电器设备",{"key":24,"text":393,"correct":22},"配电箱、开关箱的进线和出线严禁承受外力",{"key":27,"text":395,"correct":29},"配电箱、开关箱内漏电保护器每天使用前应启动实验按钮试跳一次,不正常时也可使用",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":66,"analysis":31},942985,"常用低压手动电器包括( )。",[400,402,404,406],{"key":20,"text":401,"correct":22},"按钮",{"key":24,"text":403,"correct":22},"刀开关",{"key":27,"text":405,"correct":22},"组合开关",{"key":64,"text":407,"correct":22},"倒顺开关",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":141,"analysis":31},942986,"配电系统的三级配电设备主要是指( )。",[412,413,415,417],{"key":20,"text":192,"correct":22},{"key":24,"text":414,"correct":22},"分配电箱",{"key":27,"text":416,"correct":22},"开关箱",{"key":64,"text":418,"correct":29},"控制按钮",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":66,"analysis":31},942987,"临时用电验收表中明确规定,用电档案中的施工组织设计内容必须包括 ( )。",[423,425,427,429],{"key":20,"text":424,"correct":22},"临电计算书",{"key":24,"text":426,"correct":22},"平面图",{"key":27,"text":428,"correct":22},"立面图",{"key":64,"text":430,"correct":22},"系统接线图",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":66,"analysis":31},942988,"电工仪表按测量方式不同可分为( )",[435,437,439,441],{"key":20,"text":436,"correct":22},"直读指示仪表",{"key":24,"text":438,"correct":22},"比较仪表",{"key":27,"text":440,"correct":22},"图示仪表",{"key":64,"text":442,"correct":22},"数字仪表",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":141,"analysis":31},942989,"关于临时用电三项基本技术原则的内容,下列说法哪一种不正确( )",[447,449,451,453,455],{"key":20,"text":448,"correct":22},"二级配电系统、TN-S接零保护系统、二级漏电保护系统",{"key":24,"text":450,"correct":22},"三级配电系统、TN-S接零保护系统、三级漏电保护系统",{"key":27,"text":452,"correct":22},"三级配电系统、TN-C接零保护系统、二级漏电保护系统",{"key":64,"text":454,"correct":29},"三级配电系统、TN-S接零保护系统、二级漏电保护系统",{"key":80,"text":456,"correct":29},"三级配电系统、TN-C-S接零保护系统、二级漏电保护系统",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":30,"analysis":31},942990,"关于配电箱和开关箱,下列说法哪种正确( )",[461,463,465],{"key":20,"text":462,"correct":22},"配电箱内应设置电器安装版",{"key":24,"text":464,"correct":22},"电器安装版可采用金属或非木质阻燃材料",{"key":27,"text":466,"correct":29},"分配电箱与开关箱可不设置电器安装版",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":479,"analysis":31},942991,"漏电保护器按其动作速度又分为( )。",[471,473,475,477],{"key":20,"text":472,"correct":22},"高速型",{"key":24,"text":474,"correct":29},"低速型",{"key":27,"text":476,"correct":22},"延时型",{"key":64,"text":478,"correct":22},"反时限型","ACD",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":30,"analysis":31},942992,"搭设外电防护设施的主要材料是( )。",[484,486,488,490,492],{"key":20,"text":485,"correct":22},"木材",{"key":24,"text":487,"correct":22},"竹材",{"key":27,"text":489,"correct":29},"钢管",{"key":64,"text":491,"correct":29},"钢筋",{"key":80,"text":493,"correct":29},"安全网",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":372,"analysis":31},942993,"下列产品哪些( )应当具备中国强制认证标志(即“CCC”认证),禁止不合格产品在施工现场使用。",[498,500,502,504,506],{"key":20,"text":499,"correct":22},"各类配电箱、开关箱及其配电材料",{"key":24,"text":501,"correct":22},"电器元件",{"key":27,"text":503,"correct":29},"架空电线",{"key":64,"text":505,"correct":22},"绝缘电缆",{"key":80,"text":507,"correct":22},"照明器等低压电器产品",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":141,"analysis":31},942994,"总配电柜应装设电源隔离开关及( )",[512,514,516,518],{"key":20,"text":513,"correct":22},"短路保护电器",{"key":24,"text":515,"correct":22},"过载保护电器",{"key":27,"text":517,"correct":22},"漏电保护电器",{"key":64,"text":519,"correct":29},"电流敏感器",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":372,"analysis":31},942995,"配电箱中的断路器在正常情况下可用于( )",[524,526,528,529,531],{"key":20,"text":525,"correct":22},"接通与分断空载电路",{"key":24,"text":527,"correct":22},"接通与分断负载电路",{"key":27,"text":178,"correct":29},{"key":64,"text":530,"correct":22},"电路的过载保护",{"key":80,"text":532,"correct":22},"电路的短路保护",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":327,"analysis":31},942996,"施工现场禁止使用木制配电箱,淘汰( )或不符合标准的移动卷线开关盘,必须使用由专业厂家生产并符合用电规范的各种系列配电箱、开关箱。",[537,539,541,543,545],{"key":20,"text":538,"correct":22},"因铁板锈蚀的老旧铁壳开关箱",{"key":24,"text":540,"correct":22},"电气元件布设不合理的老旧铁壳开关箱",{"key":27,"text":542,"correct":22},"进出线口不在箱体底部",{"key":64,"text":544,"correct":22},"无零线端子板的老旧铁壳开关箱",{"key":80,"text":546,"correct":22},"自制配电箱",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":106,"analysis":31},942997,"关于开关箱的安全使用,下列说法哪一种是正确的( )。",[551,553,555,557],{"key":20,"text":552,"correct":29},"“一机一箱”是指每台用电设备都应使用开关箱供电,开关箱可以混用。",{"key":24,"text":554,"correct":22},"“一机一闸”是指开关箱内的电源开关只能控制一台电气设备。",{"key":27,"text":556,"correct":22},"“一机一漏”是指开关箱内应安装漏电保护器。",{"key":64,"text":558,"correct":22},"“一箱一锁”是指每个开关箱都要配锁。",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":141,"analysis":31},942998,"采用伪劣产品导线可能会导致什么现象发生?( )",[563,565,567],{"key":20,"text":564,"correct":22},"线路电压损失增大",{"key":24,"text":566,"correct":22},"电压不稳定",{"key":27,"text":568,"correct":22},"火灾",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":66,"analysis":31},942999,"施工现场与电气安全有关的危险环境因素主要有( )等。",[573,575,577,579],{"key":20,"text":574,"correct":22},"外电线路",{"key":24,"text":576,"correct":22},"易燃易爆物",{"key":27,"text":578,"correct":22},"腐蚀介质",{"key":64,"text":580,"correct":22},"机械损伤",{"id":582,"libraryId":5,"type":15,"typeLabel":16,"stem":583,"options":584,"answer":66,"analysis":31},943000,"总配电箱中漏电保护器的额定漏电动作电流IΔ和额定漏电动作时间TΔ,可分别选择为( )。",[585,587,589,591,593],{"key":20,"text":586,"correct":22},"IΔ=50mA TΔ=0",{"key":24,"text":588,"correct":22},"IΔ=75mA TΔ=0",{"key":27,"text":590,"correct":22},"IΔ=100mA TΔ=0",{"key":64,"text":592,"correct":22},"IΔ=200mA TΔ=0",{"key":80,"text":594,"correct":29},"IΔ=500mA TΔ=0",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":93,"analysis":31},943001,"施工现场需要编制用电组织设计的基准条件是( )",[599,601,603,605,607],{"key":20,"text":600,"correct":22},"用电设备5台及以上",{"key":24,"text":602,"correct":29},"用电设备10台及以上",{"key":27,"text":604,"correct":22},"用电设备总容量50kW及以上",{"key":64,"text":606,"correct":29},"用电设备总容量100kW及以上",{"key":80,"text":608,"correct":29},"用电设备5台及以上,且用电设备总容量100kW及以上",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":141,"analysis":31},943002,"关于隔离开关,下列说法哪一种是正确的( )。",[613,615,617,619],{"key":20,"text":614,"correct":22},"应设置于电源的进线端",{"key":24,"text":616,"correct":22},"应具有明显可见分断点",{"key":27,"text":618,"correct":22},"能同时断开电源所有电极",{"key":64,"text":620,"correct":29},"采用具有可见分断点的断路器,同时仍须设置隔离开关",{"id":622,"libraryId":5,"type":15,"typeLabel":16,"stem":623,"options":624,"answer":93,"analysis":31},943003,"关于分配电箱、下列说法哪种正确( )",[625,627,629],{"key":20,"text":626,"correct":22},"隔离开关设置于电源进线端",{"key":24,"text":628,"correct":29},"每一分路上还应设置分路漏电保护器",{"key":27,"text":630,"correct":22},"每一分路上还应装设分路隔离开关、分路断路器、或分路熔断器",[632,636,639,642,645,648],{"id":633,"name":634,"category":7,"favorite":635},1,"领导干部任职前廉政法规知识测试题",92,{"id":637,"name":638,"category":7,"favorite":633},595,"建筑结构与设备",{"id":640,"name":641,"category":7,"favorite":633},715,"招标采购专业知识与法律法规",{"id":643,"name":644,"category":7,"favorite":633},848,"市政方向-通用基础",{"id":646,"name":647,"category":7,"favorite":8},534,"BIM工程师",{"id":649,"name":647,"category":7,"favorite":8},535]