[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-666-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":577},{"id":5,"name":6,"category":7,"favorite":8},666,"建筑电工","建筑工程",0,1,50,1106,[13,30,40,50,60,73,85,95,107,119,129,137,149,161,173,185,197,209,221,233,242,252,263,275,287,299,307,319,331,339,351,363,375,387,397,409,421,433,445,457,466,476,488,500,508,520,532,542,554,565],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":19,"analysis":29},942402,"单选题","使用电气设备时,由于维护不及时,当( )进入时,可导致短路事故。",[18,22,26],{"key":19,"text":20,"correct":21},"A","导电粉尘或纤维",true,{"key":23,"text":24,"correct":25},"B","强光辐射",false,{"key":27,"text":28,"correct":25},"C","热气","",{"id":31,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":33,"answer":19,"analysis":29},942403,"漏电保护器的使用是防止( )。",[34,36,38],{"key":19,"text":35,"correct":21},"触电事故",{"key":23,"text":37,"correct":25},"电压波动",{"key":27,"text":39,"correct":25},"电荷超负荷",{"id":41,"libraryId":5,"type":9,"typeLabel":15,"stem":42,"options":43,"answer":23,"analysis":29},942404,"如果工作场所潮湿,为避免触电,使用手持电动工具的人应( )。",[44,46,48],{"key":19,"text":45,"correct":25},"站在铁板上操作",{"key":23,"text":47,"correct":21},"站在绝缘胶板上操作",{"key":27,"text":49,"correct":25},"穿防静电鞋操作",{"id":51,"libraryId":5,"type":9,"typeLabel":15,"stem":52,"options":53,"answer":27,"analysis":29},942405,"国际规定，电压( )伏以下不必考虑防止电击的危险。",[54,56,58],{"key":19,"text":55,"correct":25},"36伏",{"key":23,"text":57,"correct":25},"65伏",{"key":27,"text":59,"correct":21},"25伏",{"id":61,"libraryId":5,"type":9,"typeLabel":15,"stem":62,"options":63,"answer":27,"analysis":29},942406,"施工现场用电系统中,N线的绝缘色应是( )。",[64,66,68,70],{"key":19,"text":65,"correct":25},"黑色",{"key":23,"text":67,"correct":25},"白色",{"key":27,"text":69,"correct":21},"淡蓝色",{"key":71,"text":72,"correct":25},"D","棕色",{"id":74,"libraryId":5,"type":9,"typeLabel":15,"stem":75,"options":76,"answer":23,"analysis":29},942407,"潮湿场所开关箱中的漏电保护器,其额定漏电动作电流为( )。",[77,79,81,83],{"key":19,"text":78,"correct":25},"15mA",{"key":23,"text":80,"correct":21},"不大于15mA",{"key":27,"text":82,"correct":25},"30mA",{"key":71,"text":84,"correct":25},"不大于30mA",{"id":86,"libraryId":5,"type":9,"typeLabel":15,"stem":87,"options":88,"answer":71,"analysis":29},942408,"一般场所开关箱漏电保护器,其额定漏电动作电流为( )。",[89,91,93,94],{"key":19,"text":90,"correct":25},"10mA",{"key":23,"text":92,"correct":25},"20mA",{"key":27,"text":82,"correct":25},{"key":71,"text":84,"correct":21},{"id":96,"libraryId":5,"type":9,"typeLabel":15,"stem":97,"options":98,"answer":71,"analysis":29},942409,"电气设备的保护零线与工作零线分开设置的系统,即称为( )系统。",[99,101,103,105],{"key":19,"text":100,"correct":25},"TT",{"key":23,"text":102,"correct":25},"TN-C",{"key":27,"text":104,"correct":25},"TN",{"key":71,"text":106,"correct":21},"TN-S",{"id":108,"libraryId":5,"type":9,"typeLabel":15,"stem":109,"options":110,"answer":23,"analysis":29},942410,"相线截面＞35mm²时，PE线截面为( )。",[111,113,115,117],{"key":19,"text":112,"correct":25},"16mm2",{"key":23,"text":114,"correct":21},"相线截面的一半",{"key":27,"text":116,"correct":25},"与相线相同",{"key":71,"text":118,"correct":25},"4mm2",{"id":120,"libraryId":5,"type":9,"typeLabel":15,"stem":121,"options":122,"answer":19,"analysis":29},942411,"16mm²＜相截面≤35mm²时，PE线截面为( )。",[123,125,126,127],{"key":19,"text":124,"correct":21},"16mm²",{"key":23,"text":114,"correct":25},{"key":27,"text":116,"correct":25},{"key":71,"text":128,"correct":25},"4mm²",{"id":130,"libraryId":5,"type":9,"typeLabel":15,"stem":131,"options":132,"answer":27,"analysis":29},942412,"PE线截面选择：当与相线材质相同时，应满足：相线截面≤16mm²时，PE线截面为( )。",[133,134,135,136],{"key":19,"text":112,"correct":25},{"key":23,"text":114,"correct":25},{"key":27,"text":116,"correct":21},{"key":71,"text":118,"correct":25},{"id":138,"libraryId":5,"type":9,"typeLabel":15,"stem":139,"options":140,"answer":27,"analysis":29},942413,"电缆埋设深度和方法要求。直埋时,应开挖深度不小于( )断面为梯形的沟槽,敷设时应在电缆近邻上.下.左.右侧均匀敷设不小于50mm厚的细砂,然后回填原土,并在地表面覆盖砖,混凝土板等硬质保护层。",[141,143,145,147],{"key":19,"text":142,"correct":25},"0.5m",{"key":23,"text":144,"correct":25},"0.6m",{"key":27,"text":146,"correct":21},"0.7m",{"key":71,"text":148,"correct":25},"0.8m",{"id":150,"libraryId":5,"type":9,"typeLabel":15,"stem":151,"options":152,"answer":27,"analysis":29},942414,"电杆的拉线宜采用镀锌钢丝,其截面不得小于3根直径( )钢丝,拉线与电杆的夹角应在30°～45°之间。",[153,155,157,159],{"key":19,"text":154,"correct":25},"2mm",{"key":23,"text":156,"correct":25},"3mm",{"key":27,"text":158,"correct":21},"4mm",{"key":71,"text":160,"correct":25},"5mm",{"id":162,"libraryId":5,"type":9,"typeLabel":15,"stem":163,"options":164,"answer":23,"analysis":29},942415,"PE线所用材质与相线。工作零线（N）相同时，其最小截面应符合规定，例如采用相线截面S为25mm²时，其PE先最小截面为( )。",[165,167,169,171],{"key":19,"text":166,"correct":25},"10",{"key":23,"text":168,"correct":21},"16",{"key":27,"text":170,"correct":25},"25",{"key":71,"text":172,"correct":25},"S\u002F2",{"id":174,"libraryId":5,"type":9,"typeLabel":15,"stem":175,"options":176,"answer":23,"analysis":29},942416,"施工现场临时用电系统重复接地装置设置一般不应少于( )处。",[177,179,181,183],{"key":19,"text":178,"correct":25},"2处",{"key":23,"text":180,"correct":21},"3处",{"key":27,"text":182,"correct":25},"4处",{"key":71,"text":184,"correct":25},"5处",{"id":186,"libraryId":5,"type":9,"typeLabel":15,"stem":187,"options":188,"answer":27,"analysis":29},942417,"漏电保护器在安装前,有条件的最好进行动作特性参数测试,安装投入使用后,在使用过程中应( )检验一次,以保证其始终能可靠运行。",[189,191,193,195],{"key":19,"text":190,"correct":25},"每周",{"key":23,"text":192,"correct":25},"半月",{"key":27,"text":194,"correct":21},"每个月",{"key":71,"text":196,"correct":25},"每季度",{"id":198,"libraryId":5,"type":9,"typeLabel":15,"stem":199,"options":200,"answer":27,"analysis":29},942418,"防直雷击装置的设置，对于施工现场高大建筑机械和高架金属设施来说，接闪器应设置于其最顶端，可采用直径为( )，及以上的圆钢。",[201,203,205,207],{"key":19,"text":202,"correct":25},"10mm",{"key":23,"text":204,"correct":25},"15mm",{"key":27,"text":206,"correct":21},"20mm",{"key":71,"text":208,"correct":25},"25mm",{"id":210,"libraryId":5,"type":9,"typeLabel":15,"stem":211,"options":212,"answer":23,"analysis":29},942419,"当外电线路达到10kV时，在建工程（含脚手架）的周边与外电线路边线的安全操作距离为( )。",[213,215,217,219],{"key":19,"text":214,"correct":25},"4m",{"key":23,"text":216,"correct":21},"6m",{"key":27,"text":218,"correct":25},"7m",{"key":71,"text":220,"correct":25},"9m",{"id":222,"libraryId":5,"type":9,"typeLabel":15,"stem":223,"options":224,"answer":23,"analysis":29},942420,"特别潮湿.导电良好的地面.锅炉或金属容器等触电高度危险场所,照明电源电压不得大于( )。",[225,227,229,231],{"key":19,"text":226,"correct":25},"6V",{"key":23,"text":228,"correct":21},"12V",{"key":27,"text":230,"correct":25},"24V",{"key":71,"text":232,"correct":25},"36V",{"id":234,"libraryId":5,"type":9,"typeLabel":15,"stem":235,"options":236,"answer":27,"analysis":29},942421,"施工的隧道.人防工程.高温.有导电灰尘.比较潮湿或灯具离地面高度低于规定2.5m等较易触电的场所,照明电源电压不应大于( )。",[237,238,239,240],{"key":19,"text":228,"correct":25},{"key":23,"text":230,"correct":25},{"key":27,"text":232,"correct":21},{"key":71,"text":241,"correct":25},"48V",{"id":243,"libraryId":5,"type":9,"typeLabel":15,"stem":244,"options":245,"answer":27,"analysis":29},942422,"架空线应分线敷设,不得集束敷设,横担上相邻导线线间距不得小于0.3m,靠近电杆两侧导线的线间距不得小于( )。",[246,248,250,251],{"key":19,"text":247,"correct":25},"0.3m",{"key":23,"text":249,"correct":25},"0.4m",{"key":27,"text":142,"correct":21},{"key":71,"text":144,"correct":25},{"id":253,"libraryId":5,"type":9,"typeLabel":15,"stem":254,"options":255,"answer":27,"analysis":29},942423,"根据设计要求,施工现场配电室顶棚的高度应当距地面不低于( )。",[256,258,260,262],{"key":19,"text":257,"correct":25},"2m",{"key":23,"text":259,"correct":25},"2.5m",{"key":27,"text":261,"correct":21},"3m",{"key":71,"text":214,"correct":25},{"id":264,"libraryId":5,"type":9,"typeLabel":15,"stem":265,"options":266,"answer":19,"analysis":29},942424,"在建筑施工现场临时用电系统中,工作接地(工频)电阻值不得大于( )。",[267,269,271,273],{"key":19,"text":268,"correct":21},"4Ω",{"key":23,"text":270,"correct":25},"10Ω",{"key":27,"text":272,"correct":25},"20Ω",{"key":71,"text":274,"correct":25},"30Ω",{"id":276,"libraryId":5,"type":9,"typeLabel":15,"stem":277,"options":278,"answer":27,"analysis":29},942425,"接地体和接地线之间的连接必须采用焊接,扁钢与钢管（或角钢）焊接时,搭接长度为扁钢宽度的2倍,且至少( )焊接。",[279,281,283,285],{"key":19,"text":280,"correct":25},"1面",{"key":23,"text":282,"correct":25},"2面",{"key":27,"text":284,"correct":21},"3面",{"key":71,"text":286,"correct":25},"4面",{"id":288,"libraryId":5,"type":9,"typeLabel":15,"stem":289,"options":290,"answer":23,"analysis":29},942426,"做人工接地体，圆钢与钢管（或角钢）焊接时，搭接长度为圆钢直径的6倍，且至少( )长面焊接。",[291,293,295,297],{"key":19,"text":292,"correct":25},"1个",{"key":23,"text":294,"correct":21},"2个",{"key":27,"text":296,"correct":25},"3个",{"key":71,"text":298,"correct":25},"4个",{"id":300,"libraryId":5,"type":9,"typeLabel":15,"stem":301,"options":302,"answer":23,"analysis":29},942427,"施工现场临时用电系统的重复接地电阻不应大于( )。",[303,304,305,306],{"key":19,"text":268,"correct":25},{"key":23,"text":270,"correct":21},{"key":27,"text":272,"correct":25},{"key":71,"text":274,"correct":25},{"id":308,"libraryId":5,"type":9,"typeLabel":15,"stem":309,"options":310,"answer":27,"analysis":29},942428,"检查绝缘电阻,一般的漏电保护器需在进.出线端子间,各接线端子与外壳间,接线端子之间进行绝缘电阻测量,其绝缘电阻值应不低于( )。",[311,313,315,317],{"key":19,"text":312,"correct":25},"0.5MΩ",{"key":23,"text":314,"correct":25},"1MΩ",{"key":27,"text":316,"correct":21},"1.5MΩ",{"key":71,"text":318,"correct":25},"2MΩ",{"id":320,"libraryId":5,"type":9,"typeLabel":15,"stem":321,"options":322,"answer":27,"analysis":29},942429,"施工现场临时用电线路的专用保护零线应采用( )线。",[323,325,327,329],{"key":19,"text":324,"correct":25},"红线",{"key":23,"text":326,"correct":25},"黑线",{"key":27,"text":328,"correct":21},"绿\u002F黄双色",{"key":71,"text":330,"correct":25},"黄色",{"id":332,"libraryId":5,"type":9,"typeLabel":15,"stem":333,"options":334,"answer":71,"analysis":29},942430,"施工现场特别潮湿场所在使用安全电压额定值时应选用( )。",[335,336,337,338],{"key":19,"text":241,"correct":25},{"key":23,"text":232,"correct":25},{"key":27,"text":230,"correct":25},{"key":71,"text":228,"correct":21},{"id":340,"libraryId":5,"type":9,"typeLabel":15,"stem":341,"options":342,"answer":27,"analysis":29},942431,"我国工频交流电频率是( )HZ。",[343,345,347,349],{"key":19,"text":344,"correct":25},"30",{"key":23,"text":346,"correct":25},"40",{"key":27,"text":348,"correct":21},"50",{"key":71,"text":350,"correct":25},"60",{"id":352,"libraryId":5,"type":9,"typeLabel":15,"stem":353,"options":354,"answer":27,"analysis":29},942432,"手持电动工具按其绝缘和防触电性能可分为( )类。",[355,357,359,361],{"key":19,"text":356,"correct":25},"一类",{"key":23,"text":358,"correct":25},"二类",{"key":27,"text":360,"correct":21},"三类",{"key":71,"text":362,"correct":25},"四类",{"id":364,"libraryId":5,"type":9,"typeLabel":15,"stem":365,"options":366,"answer":23,"analysis":29},942433,"施工现场自备电源通常是( )。",[367,369,371,373],{"key":19,"text":368,"correct":25},"南孚电池",{"key":23,"text":370,"correct":21},"发电机",{"key":27,"text":372,"correct":25},"铅蓄电池",{"key":71,"text":374,"correct":25},"直流不间断电源",{"id":376,"libraryId":5,"type":9,"typeLabel":15,"stem":377,"options":378,"answer":19,"analysis":29},942434,"漏电保护器又称漏电开关,是用于在电路或电器绝缘受损发生对地短路时防止人身触电和电气火灾的( )。",[379,381,383,385],{"key":19,"text":380,"correct":21},"保护电器",{"key":23,"text":382,"correct":25},"继电器",{"key":27,"text":384,"correct":25},"主令电器",{"key":71,"text":386,"correct":25},"低压配电器",{"id":388,"libraryId":5,"type":9,"typeLabel":15,"stem":389,"options":390,"answer":27,"analysis":29},942435,"行灯的电源电压不得大于( )。",[391,393,395,396],{"key":19,"text":392,"correct":25},"220V",{"key":23,"text":394,"correct":25},"110V",{"key":27,"text":232,"correct":21},{"key":71,"text":230,"correct":25},{"id":398,"libraryId":5,"type":9,"typeLabel":15,"stem":399,"options":400,"answer":19,"analysis":29},942436,"开关箱中设置刀型开关DK.断路器KK.漏电保护器RCD,则从电源进线端开始其联系次序应依次是( )",[401,403,405,407],{"key":19,"text":402,"correct":21},"DK-KK-RCD",{"key":23,"text":404,"correct":25},"DK-RCD-KK",{"key":27,"text":406,"correct":25},"KK-RCD-DK",{"key":71,"text":408,"correct":25},"RCD-KK-DK",{"id":410,"libraryId":5,"type":9,"typeLabel":15,"stem":411,"options":412,"answer":23,"analysis":29},942437,"开关箱中的刀开关可用于不平繁操作控制电动机的最大容量是( )",[413,415,417,419],{"key":19,"text":414,"correct":25},"2.2KW",{"key":23,"text":416,"correct":21},"3.0KW",{"key":27,"text":418,"correct":25},"4.0KW",{"key":71,"text":420,"correct":25},"5.5KW",{"id":422,"libraryId":5,"type":9,"typeLabel":15,"stem":423,"options":424,"answer":71,"analysis":29},942438,"总配电箱中漏电保护器的额定漏电保护电流和额定漏电动作时间的选择要求是( )",[425,427,429,431],{"key":19,"text":426,"correct":25},"IΔ>30mATΔ=0.1s",{"key":23,"text":428,"correct":25},"IΔ=30mATΔ>0.1s",{"key":27,"text":430,"correct":25},"IΔ>30mATΔ>0.1s",{"key":71,"text":432,"correct":21},"IΔ>30mATΔ>0.1s,IΔ•TΔ不大与30mA•0.1s",{"id":434,"libraryId":5,"type":9,"typeLabel":15,"stem":435,"options":436,"answer":23,"analysis":29},942439,"架空线路的同一横担上，L1（A）、L2（B）、L3(C)、N、PE五条线的排列次序是面向负荷侧从左起依次为( )。",[437,439,441,443],{"key":19,"text":438,"correct":25},"L1、L2、L3、N、PE",{"key":23,"text":440,"correct":21},"L1、N、L2、L3、PE",{"key":27,"text":442,"correct":25},"L1、L2、N、L3、PE",{"key":71,"text":444,"correct":25},"N、PE、L1、L2、L3",{"id":446,"libraryId":5,"type":9,"typeLabel":15,"stem":447,"options":448,"answer":27,"analysis":29},942440,"施工现场用电工程基本供配电系统应按( )",[449,451,453,455],{"key":19,"text":450,"correct":25},"一级",{"key":23,"text":452,"correct":25},"二级",{"key":27,"text":454,"correct":21},"三级",{"key":71,"text":456,"correct":25},"四级",{"id":458,"libraryId":5,"type":9,"typeLabel":15,"stem":459,"options":460,"answer":19,"analysis":29},942441,"施工现场和机动车道与220\u002F380V架空线路交叉时的最小垂直距离应是( )",[461,462,464,465],{"key":19,"text":214,"correct":21},{"key":23,"text":463,"correct":25},"5m",{"key":27,"text":216,"correct":25},{"key":71,"text":218,"correct":25},{"id":467,"libraryId":5,"type":9,"typeLabel":15,"stem":468,"options":469,"answer":23,"analysis":29},942442,"在建工程（含脚手架具）周边与10kV外电架空线路边线之间的最小安全距离是( )。",[470,471,472,474],{"key":19,"text":214,"correct":25},{"key":23,"text":216,"correct":21},{"key":27,"text":473,"correct":25},"8m",{"key":71,"text":475,"correct":25},"10m",{"id":477,"libraryId":5,"type":9,"typeLabel":15,"stem":478,"options":479,"answer":19,"analysis":29},942443,"施工现场用电系统中,连接用电设备外露可导部分的PE线应采用( )",[480,482,484,486],{"key":19,"text":481,"correct":21},"绝缘铜线",{"key":23,"text":483,"correct":25},"绝缘铝线",{"key":27,"text":485,"correct":25},"裸铜线",{"key":71,"text":487,"correct":25},"钢筋",{"id":489,"libraryId":5,"type":9,"typeLabel":15,"stem":490,"options":491,"answer":19,"analysis":29},942444,"施工现场用电过程中,PE线上每处重复接地的接地电阻值不应大于( )",[492,494,496,498],{"key":19,"text":493,"correct":21},"4欧姆",{"key":23,"text":495,"correct":25},"10欧姆",{"key":27,"text":497,"correct":25},"30欧姆",{"key":71,"text":499,"correct":25},"100欧姆",{"id":501,"libraryId":5,"type":9,"typeLabel":15,"stem":502,"options":503,"answer":23,"analysis":29},942445,"施工现场专用的,电源中性点直接接地的220\u002F380V三相四线制用电过程中,必须采用接地保护形式是( )",[504,505,506,507],{"key":19,"text":104,"correct":25},{"key":23,"text":106,"correct":21},{"key":27,"text":102,"correct":25},{"key":71,"text":100,"correct":25},{"id":509,"libraryId":5,"type":9,"typeLabel":15,"stem":510,"options":511,"answer":71,"analysis":29},942446,"绝缘线接头要连接牢固、可靠，架空线在一个档距内，每层导线接头数不得超过该层导线条数的( )，且一条导线只允许有一个接头。",[512,514,516,518],{"key":19,"text":513,"correct":25},"20%",{"key":23,"text":515,"correct":25},"30%",{"key":27,"text":517,"correct":25},"40%",{"key":71,"text":519,"correct":21},"50%",{"id":521,"libraryId":5,"type":9,"typeLabel":15,"stem":522,"options":523,"answer":23,"analysis":29},942447,"链式配线适用于相距较近,且不太重要的小容量负荷场所,但链接独立负荷不宜超过( )个。",[524,526,528,530],{"key":19,"text":525,"correct":25},"2～3",{"key":23,"text":527,"correct":21},"3～4",{"key":27,"text":529,"correct":25},"4～5",{"key":71,"text":531,"correct":25},"5～6",{"id":533,"libraryId":5,"type":9,"typeLabel":15,"stem":534,"options":535,"answer":23,"analysis":29},942448,"配电室内设值班室,该室边缘距配电柜的水平距离大于( )并采用屏障隔离。",[536,537,539,541],{"key":19,"text":142,"correct":25},{"key":23,"text":538,"correct":21},"1m",{"key":27,"text":540,"correct":25},"1.5m",{"key":71,"text":257,"correct":25},{"id":543,"libraryId":5,"type":9,"typeLabel":15,"stem":544,"options":545,"answer":27,"analysis":29},942449,"电动机功率的选择，应根据实际需要的功率来选择电动机，可根据电动机的额定功率等于实际需要功率的( )进行选择。",[546,548,550,552],{"key":19,"text":547,"correct":25},"1倍",{"key":23,"text":549,"correct":25},"1.1倍",{"key":27,"text":551,"correct":21},"1.1—1.2倍",{"key":71,"text":553,"correct":25},"1.2倍",{"id":555,"libraryId":5,"type":9,"typeLabel":15,"stem":556,"options":557,"answer":27,"analysis":29},942450,"刀开关一般用于空载操作,也可用于控制不经常启动的容量小于3KW的异步电动机,当用于启动异步电动机时,其额定电流应不小于电动机额定电流的( )。",[558,559,561,563],{"key":19,"text":547,"correct":25},{"key":23,"text":560,"correct":25},"2倍",{"key":27,"text":562,"correct":21},"3倍",{"key":71,"text":564,"correct":25},"4倍",{"id":566,"libraryId":5,"type":9,"typeLabel":15,"stem":567,"options":568,"answer":27,"analysis":29},942451,"三相负载有功功率的表达式为( )。",[569,571,573,575],{"key":19,"text":570,"correct":25},"P=UIcosφ",{"key":23,"text":572,"correct":25},"P=Scosφ",{"key":27,"text":574,"correct":21},"P= Uicos&phi;",{"key":71,"text":576,"correct":25},"cosφ=P\u002FS",[578,581,584,587,590,593],{"id":9,"name":579,"category":7,"favorite":580},"领导干部任职前廉政法规知识测试题",92,{"id":582,"name":583,"category":7,"favorite":9},595,"建筑结构与设备",{"id":585,"name":586,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":588,"name":589,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":591,"name":592,"category":7,"favorite":8},534,"BIM工程师",{"id":594,"name":592,"category":7,"favorite":8},535]