[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":653},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,9,50,2974,[13,34,46,58,70,82,91,103,121,133,145,160,172,184,199,211,223,235,250,262,274,289,301,313,325,337,349,361,375,387,399,411,423,435,450,464,479,491,503,515,530,542,554,566,578,590,602,614,626,638],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},935076,1,"单选题","（2019年真题）某单位设置储压型干粉灭火系统。该系统的组作不包括（）",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","容器阀",false,{"key":24,"text":25,"correct":26},"B","驱动气体储存装置",true,{"key":28,"text":29,"correct":22},"C","安全泄压装置",{"key":31,"text":32,"correct":22},"D","干粉储存容器","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},935077,"(2018年真题) 消防技术服务机构对某单位设置的预制干粉灭火装置进行验收前检测。根据现行国家标准《干粉灭火系统设计规范》(GB50374)，下列检测结果中，不符合规范要求的是( )",[38,40,42,44],{"key":20,"text":39,"correct":26},"1个防护区内设置了5套预制干粉灭火装置",{"key":24,"text":41,"correct":22},"干粉储存容器的存储压力为2.5MPa",{"key":28,"text":43,"correct":22},"预制干粉灭火装置的灭火剂储存量为120kg",{"key":31,"text":45,"correct":22},"预制干粉灭火装置的管道长度为15m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},935078,"(2016年真题) 对干粉灭火系统进行周期性检查维护管理，下列检查项目中，不属于年度功能检测项目的是（??）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"模拟启动检查",{"key":24,"text":53,"correct":26},"气瓶和干粉储罐充装量",{"key":28,"text":55,"correct":22},"模拟备用瓶组成功能试验",{"key":31,"text":57,"correct":22},"模拟紧急启停功能",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},935079,"(2017年真题)对干粉灭火系统进行维护管理时，下列检查项目中，属于每月检查一次的项目是（??）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"驱动气瓶充装量",{"key":24,"text":65,"correct":22},"启动气体储瓶压力",{"key":28,"text":67,"correct":22},"灭火控制器运行情况",{"key":31,"text":69,"correct":22},"管网、支架及喷放组件",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},935080,"(2015年真题) 下列关于干粉灭火系统管理要求的说法，正确的是（）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"储存容器允许的最低环境温度为-30°C",{"key":24,"text":77,"correct":22},"地上防护区有固定窗扇时可不设机械排风装置",{"key":28,"text":79,"correct":26},"驱动气体储瓶管理应执行《气瓶安全监察规程》",{"key":31,"text":81,"correct":22},"自动控制状态下的干粉灭火系统不得延迟喷放",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},935081,"(2016年真题) 对干粉灭火系统进行周期性检查维护管理，下列检查项目中，不属于年度功能检测项目的是（）。",[86,87,88,90],{"key":20,"text":53,"correct":26},{"key":24,"text":51,"correct":22},{"key":28,"text":89,"correct":22},"模拟备用瓶组功能试验",{"key":31,"text":57,"correct":22},{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":24,"analysis":33},935082,"（2020年真题）某消防技术服务机构对某单位安装的干粉灭火系统进行了检查。下列检查结果不符合现行国家标准《干粉灭火系统设计规范》（GB50347）要求的是（ ）。",[95,97,99,101],{"key":20,"text":96,"correct":22},"A预制干粉灭火装置灭火剂的冲装量为120kg",{"key":24,"text":98,"correct":26},"预制干粉灭火装置的管道长度为25m",{"key":28,"text":100,"correct":22},"预制干粉灭火装置的工作压力为2.5MPa",{"key":31,"text":102,"correct":22},"—个防护区内设置了两套预制干粉灭火装置，两套装置同时启动",{"id":104,"libraryId":5,"type":105,"typeLabel":106,"stem":107,"options":108,"answer":120,"analysis":33},935083,2,"多选题","(2015年真题) 灭火器日常检查中，发现灭火器达到维修条件或维修期限时，建筑使用管理单位应及时按照规定程序送修。（）的灭火器应及时送修。",[109,111,113,115,117],{"key":20,"text":110,"correct":22},"未曾使用过但出厂期刚满2年",{"key":24,"text":112,"correct":26},"机械损伤",{"key":28,"text":114,"correct":26},"筒体明显锈蚀",{"key":31,"text":116,"correct":26},"灭火剂泄露",{"key":118,"text":119,"correct":26},"E","再次维修以后刚满2年","BCDE",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":24,"analysis":33},935084,"（2019年真题）某单位工作人员在对本单位配置的灭火器进行检查时，发现其中一具干粉灭火器筒体表面轻微锈蚀，筒体有锡焊的修补痕迹，压力指针在绿区范围。根据现行国家标准《建筑灭火器配置验收及检查规范》(GB50444)，对该具灭火器的处置措施正确的是（）。",[125,127,129,131],{"key":20,"text":126,"correct":22},"筒体锈蚀处涂漆",{"key":24,"text":128,"correct":26},"报废",{"key":28,"text":130,"correct":22},"送修",{"key":31,"text":132,"correct":22},"采取防潮措施",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":24,"analysis":33},935085,"（2019年真题）对某建筑面积为300㎡的网吧配置的灭火器进行竣工验收，根据《建筑灭火器配置验收及检查规范》(GB50444)，下列验收检查结果中，不符合规范要求的是（）。",[137,139,141,143],{"key":20,"text":138,"correct":22},"每个灭火器箱内放置两具灭火器，灭火器箱的布置间距为20m",{"key":24,"text":140,"correct":26},"配置了手提式MF\u002FABC4型灭火器",{"key":28,"text":142,"correct":22},"灭火器箱为翻盖型，翻盖开启角度为105°",{"key":31,"text":144,"correct":22},"灭火器放置在网吧靠墙位置，并设有取用标志",{"id":146,"libraryId":5,"type":105,"typeLabel":106,"stem":147,"options":148,"answer":159,"analysis":33},935086,"（2019年真题）对某樟脑油提炼车间配置的灭火器进行检查，下列检查结果中，不符合现行国家标准要求的有（）",[149,151,153,155,157],{"key":20,"text":150,"correct":22},"用挂钩将灭火器悬挂在墙上，挂钩最大承载力为45kg",{"key":24,"text":152,"correct":22},"灭火器套用防护外罩",{"key":28,"text":154,"correct":26},"灭火器铭牌朝向墙面",{"key":31,"text":156,"correct":26},"灭火器顶部高离地面距离为1.60m",{"key":118,"text":158,"correct":26},"配置的灭火器类型为磷酸铵盐干粉灭火器和炭酸氢钠干粉灭火器","CDE",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":28,"analysis":33},935087,"(2018年真题) 某幼儿园共配置了20具4kg磷酸铵盐干粉灭火器，委托某消防技术服务机构进行检查维护，经检查有8 具灭火器需送修。 该幼儿园无备用灭火器，根据现行国家标准《建筑灭火器配置验收及检查规范》 (GB50444)，幼儿园一次送修的灭火器数量最多为( )。",[164,166,168,170],{"key":20,"text":165,"correct":22},"8 具",{"key":24,"text":167,"correct":22},"6 具",{"key":28,"text":169,"correct":26},"5 具",{"key":31,"text":171,"correct":22},"7 具",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":24,"analysis":33},935088,"(2018年真题) 消防技术服务机构对某建筑设置的机械防烟系统进行维护保养，其中符合现行国家标准《建筑防烟排烟系统技术标准》（GB51251）的是（）",[176,178,180,182],{"key":20,"text":177,"correct":22},"每年对全部送风口进行一次自动启动试验",{"key":24,"text":179,"correct":26},"每年对机械防烟系统进行一次联动试验",{"key":28,"text":181,"correct":22},"每半年对全部正压送风机进行一次功能检测自动试验",{"key":31,"text":183,"correct":22},"每半年对正压送风机的供电线路进行一次检查",{"id":185,"libraryId":5,"type":105,"typeLabel":106,"stem":186,"options":187,"answer":198,"analysis":33},935089,"(2016年真题)建筑灭火器配置缺陷项分为三类，分别为严重 （A）、重 （B）、轻 （C）。下列灭火器装置中，属于严重缺陷项的有（??）",[188,190,192,194,196],{"key":20,"text":189,"correct":22},"堆场上露天设置MFT\u002FABC20灭火器",{"key":24,"text":191,"correct":26},"柴油发电机房设置1具磷酸铵盐灭火器及1具碳酸氢钠灭火器",{"key":28,"text":193,"correct":22},"建筑地下室灭火器被所在灭火器箱中",{"key":31,"text":195,"correct":26},"普通住宅内配置的灭火器未取得3C认证证书",{"key":118,"text":197,"correct":26},"民用机场候机厅配置的灭火器型号为MF\u002FABC4","BDE",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":28,"analysis":33},935090,"(2017年真题)根据现行国家行业标准《灭火器维修》（GA95-2015），下列零部件和灭火剂中，无需在每次维修灭火器时都更换的是（??）。",[203,205,207,209],{"key":20,"text":204,"correct":22},"密封垫",{"key":24,"text":206,"correct":22},"二氧化碳灭火器的超压安全膜片",{"key":28,"text":208,"correct":26},"水基型灭火器的滤网",{"key":31,"text":210,"correct":22},"水基型灭火剂",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":20,"analysis":33},935091,"(2017年真题)下列检查项目中， 不属于推车式干粉灭火器进场检查项目的是（）",[215,217,219,221],{"key":20,"text":216,"correct":26},"间歇喷射机构",{"key":24,"text":218,"correct":22},"筒体",{"key":28,"text":220,"correct":22},"灭火器结构",{"key":31,"text":222,"correct":22},"行驶机构",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":20,"analysis":33},935092,"(2017年真题)某学校宿舍楼长度40m，宽度13m，建筑层数6层 ，建筑高度21m，设有室内消火栓系统 ，宿舍楼每层设置 15 间宿舍，每间宿舍学生人数为4人 ，每层中间沿长度方向设2m宽的走道，该楼每层灭火器布置的做法中， 符合现行国家标准《建筑灭火器配置设计规范》（GB50140-2005）要求的是（??）。",[227,229,231,233],{"key":20,"text":228,"correct":26},"从距走道端部5m处开始每隔10m布置一具MF／ABC5 灭火器",{"key":24,"text":230,"correct":22},"在走道尽端各5m处分别布置2具MF\u002FABC4 灭火器",{"key":28,"text":232,"correct":22},"在走道尽端各5m处分别布置2具MF\u002FABC5 灭火器",{"key":31,"text":234,"correct":22},"从距走道端部5m处开始每隔10m布置一具MS\u002FQ6 灭火器",{"id":236,"libraryId":5,"type":105,"typeLabel":106,"stem":237,"options":238,"answer":249,"analysis":33},935093,"(2017年真题)根据现行国家标准《建筑灭火器配置验收及检查规范》(GB50444-2008)， 下列灭火器中， 应报废的有（??）。",[239,241,243,245,247],{"key":20,"text":240,"correct":26},"筒体表面有凹坑的灭火器",{"key":24,"text":242,"correct":22},"出厂期满2年首次维修后， 4年内又维修2次的干粉灭火器",{"key":28,"text":244,"correct":22},"出厂满10年的二氧化碳灭火器",{"key":31,"text":246,"correct":26},"无间隙喷射机构的手提式灭火器",{"key":118,"text":248,"correct":26},"筒体为平底的灭火器","ADE",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":28,"analysis":33},935094,"(2018年真题)根据现行国家标准《建筑灭火器配置设计规范》(GB50140)，某酒店配置灭火器的做法中，不符合要求的是( )",[254,256,258,260],{"key":20,"text":255,"correct":22},"酒店多功能厅配置了水型灭火器",{"key":24,"text":257,"correct":22},"酒店的厨房间配置了泡沫灭火器",{"key":28,"text":259,"correct":26},"酒店的布草间配置了二氧化碳灭火器",{"key":31,"text":261,"correct":22},"酒店的客房区走道上配置了磷酸铵盐干粉灭火器",{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":24,"analysis":33},935095,"(2018年真题)某消防工程施工单位对进场的一批手提式二氧化碳灭火器进行现场检查，根据现行国家标准《建筑灭火器配置验收及检查规范》（GB50444），（）不属于该批灭火器的进场检查项目。",[266,268,270,272],{"key":20,"text":267,"correct":22},"市场准入证明",{"key":24,"text":269,"correct":26},"压力表指针位置",{"key":28,"text":271,"correct":22},"筒体机械损伤",{"key":31,"text":273,"correct":22},"永久性钢印标识",{"id":275,"libraryId":5,"type":105,"typeLabel":106,"stem":276,"options":277,"answer":288,"analysis":33},935096,"(2018年真题)某消防技术服务机构对某歌舞厅的灭火器进行日常检查维护。该消防技术服务机构的下列检查维护工作中，符合现行国家标准要求的有( )。",[278,280,282,284,286],{"key":20,"text":279,"correct":26},"每半月对灭火器的零部件完整性开展检查并记录",{"key":24,"text":281,"correct":22},"将筒体严重锈蚀的灭火器送至专业维修单位维修",{"key":28,"text":283,"correct":26},"每半月对灭火器的驱动气体压力开展检查并记录",{"key":31,"text":285,"correct":26},"将筒体明显锈蚀的灭火器送至该灭火器的生产企业维修",{"key":118,"text":287,"correct":26},"将灭火剂泄露的灭火器送至该灭火的生产企业维修","ACDE",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":20,"analysis":33},935097,"(2016年真题)某消防技术服务机构的检测人员对一大型商业综合体设置的各类灭火器进行检查，根据现行国家标准《建筑灭火器配置验收及检查规范》GB50444的要求，下列关于灭火器的检查结论中，正确的是（）。",[293,295,297,299],{"key":20,"text":294,"correct":26},"每月对顶层办公区域配置的灭火器进行一次检查，符合要求",{"key":24,"text":296,"correct":22},"每月对商场部分配置的灭火器进行一次检查，符合要求",{"key":28,"text":298,"correct":22},"每月对地下配置的灭火器进行一次检查，符合要求",{"key":31,"text":300,"correct":22},"每月对锅炉房配置的灭火器进行一次检查，符合要求",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":33},935098,"(2016年真题)对建筑灭火器的配置进行检查时，应注意检查灭火器的适用性，宾馆客房区域的走到上不应设置（??）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"水型灭火器",{"key":24,"text":308,"correct":26},"碳酸氢钠灭火器",{"key":28,"text":310,"correct":22},"泡沫灭火器",{"key":31,"text":312,"correct":22},"磷酸铵盐灭火器",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":33},935099,"(2016年真题)在对建筑灭火器进行防火检查时，也应注意检查灭火器箱与地面的距离，根据现行国家消防技术标准，灭火器箱底部距地面的高度不应小于（??）cm",[317,319,321,323],{"key":20,"text":318,"correct":26},"8",{"key":24,"text":320,"correct":22},"5",{"key":28,"text":322,"correct":22},"10",{"key":31,"text":324,"correct":22},"15",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":20,"analysis":33},935100,"(2016年真题)某消防技术服务机构的检测人员对一大型商业综合体设置的各类灭火器进行检查，根据现行国家标准《建造灭火器配置验收及检查规范》GB50444的要求，下列关于灭火器的检查结论，正确的是（ ）",[329,331,333,335],{"key":20,"text":330,"correct":26},"每个月对顶层办公区域配置的灭火器进行一次检查，符合要求",{"key":24,"text":332,"correct":22},"每个月对商场部分配置的灭火器进行一次检查，符合要求",{"key":28,"text":334,"correct":22},"每个月对地下室配置的灭火器进行一次检查，符合要求",{"key":31,"text":336,"correct":22},"每个月对锅炉房配置的灭火器进行一次检查，符合要求",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":20,"analysis":33},935101,"(2015年真题) 灭火器使用一定年限后，对符合报废条件、报废年限的灭火器，建筑使用管理单位应及时采购符合要求的灭火器进行等效更换。下列灭火器中，正常情况下出厂时间已满10年但不满12年可不报废的是（）。",[341,343,345,347],{"key":20,"text":342,"correct":26},"二氧化碳灭火器",{"key":24,"text":344,"correct":22},"水基型灭火器",{"key":28,"text":346,"correct":22},"洁净气体灭火器",{"key":31,"text":348,"correct":22},"干粉灭火器",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":28,"analysis":33},935102,"(2015年真题) 对在同一配置单元内设置有两种类型的灭火器的场所进行验收检查时，下列检查结论中正确的是（）。",[353,355,357,359],{"key":20,"text":354,"correct":22},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，而且两种灭火剂的充装量相等，判定灭火器的配置合格",{"key":24,"text":356,"correct":22},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，而且两种灭火剂的类型不相容，判定灭火器的配置合格",{"key":28,"text":358,"correct":26},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，而且两种灭火剂的类型相容，判定灭火器的配置合格",{"key":31,"text":360,"correct":22},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，但两种灭火剂的充装量不相等，判定灭火器的配置不合格",{"id":362,"libraryId":5,"type":105,"typeLabel":106,"stem":363,"options":364,"answer":288,"analysis":33},935103,"（2020年真题）某消防安全重点单位开展消防设施和器材检查，根据现行国家标准《建筑灭火器配置验收及检查规范》（GB 50444）,下列检查内容中，属于建筑灭火器外观检查内容和要求的有（ ）。",[365,367,369,371,373],{"key":20,"text":366,"correct":26},"灭火器的铅封，销闩等保险装置是香完好有效",{"key":24,"text":368,"correct":22},"灭火器周围是否存在有障碍物，遮挡，栓系等影响取用的现象",{"key":28,"text":370,"correct":26},"灭火器箱是杏上锁，箱内是否干净",{"key":31,"text":372,"correct":26},"灭火器的铭牌是否残缺并清晰明了。",{"key":118,"text":374,"correct":26},"灭火器的零部件是香齐全无松动脱落或损伤",{"id":376,"libraryId":5,"type":15,"typeLabel":16,"stem":377,"options":378,"answer":24,"analysis":33},935104,"（2020年真题）某独立建造的老年人照料设施,建筑高度为27m,地上8层,每层建筑面积1200㎡。对该老年人照料设施开展消防安全评估,下列检查结果中,不属于判定检查项中关键项的是（ ）",[379,381,383,385],{"key":20,"text":380,"correct":22},"位于走道尽端的房间仅设置1个净宽为1.2m的疏散门",{"key":24,"text":382,"correct":26},"建筑内设置了ABC类干粉灭火器",{"key":28,"text":384,"correct":22},"疏散楼梯最小净宽为1.2m",{"key":31,"text":386,"correct":22},"未设置消防车登高操作场",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":28,"analysis":33},935105,"（2019年真题）某地上3层汽车库,每层建筑面积为3600㎡,建筑高度为12m，采用自然排烟,对该车库的下列防火检查结果中,不符合现行国家标准要求的是（）",[391,393,395,397],{"key":20,"text":392,"correct":22},"外墙上排烟口采用上悬窗",{"key":24,"text":394,"correct":22},"屋顶的排烟口采用平推窗",{"key":28,"text":396,"correct":26},"每层自然排烟口的总面积为54㎡",{"key":31,"text":398,"correct":22},"防烟分区内最远点距排烟口的距离为30m",{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":24,"analysis":33},935106,"（2019年真题）某消防救援机构对某商业综合体设置的挡烟垂壁进行监督检查，下列检查结果中，不符合现行国家标准《建筑防烟排烟系统技术标准》(GB51251)要求的是（）",[403,405,407,409],{"key":20,"text":404,"correct":22},"活动挡烟垂壁的手动操作按钮安装在距楼地面1.4m的墙面上",{"key":24,"text":406,"correct":26},"活动挡烟垂壁与墙面、柱面的缝隙为70mm",{"key":28,"text":408,"correct":22},"由两块活动挡烟垂帘组成的连续性挡烟垂壁，挡烟垂帘搭接宽度为200mm",{"key":31,"text":410,"correct":22},"活动挡烟垂壁由无机纤维织物材料制作",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":28,"analysis":33},935107,"（2019年真题）根据现行国家标准,《建筑消防设施的维护管理》GB25201),（）不属于每日应对防排烟系统进行巡查的项目。",[415,417,419,421],{"key":20,"text":416,"correct":22},"挡烟垂壁的外观",{"key":24,"text":418,"correct":22},"送风机房的环境",{"key":28,"text":420,"correct":26},"排烟风机的供电线路",{"key":31,"text":422,"correct":22},"风机控制柜的工作状态",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":20,"analysis":33},935108,"（2019年真题）对某建筑高度为110m的写字楼设置的机械加压送风系统进行检查时，下列系统送风口风压测试的做法，符合现行国家标准《建筑防排烟系统技术标准》(GB51251)要求的是（）。",[427,429,431,433],{"key":20,"text":428,"correct":26},"选择第十五层避难层的机械加压送风系统，测试风口的风压值",{"key":24,"text":430,"correct":22},"选择送风系统首端对应的3个连续楼层的楼梯间及前室，测试风口的风压值",{"key":28,"text":432,"correct":22},"选择送风系统末端对应的1个楼层的楼梯间及前室，测试风口的风压值",{"key":31,"text":434,"correct":22},"选择送风系统中段对应的2个连续楼层的楼梯间及前室，测试风口的风压值",{"id":436,"libraryId":5,"type":105,"typeLabel":106,"stem":437,"options":438,"answer":449,"analysis":33},935109,"（2019年真题）某20层大厦每层为一个防火分区，防烟楼梯间及前室安装了机械加压达风系统。下列对该系统进行联动调试的方法和测试结果中，符合现行国家标准《建筑防烟排烟系统技术标准》(GB51251)要求的有（）。",[439,441,443,445,447],{"key":20,"text":440,"correct":26},"手动开启第六层楼梯间前室内的常闭送风口，相应的加压送风机联动启动",{"key":24,"text":442,"correct":26},"使第九层的两只独立的感深测器报警，相应的送风口和加压送风机联动启动",{"key":28,"text":444,"correct":26},"风机联动启动后，在顶层楼梯间送风口处测得的风速为5m\u002Fs",{"key":31,"text":446,"correct":22},"按下第十层楼梯间前室门口的一只手动报警按钮，相应的加压送风机联动启动",{"key":118,"text":448,"correct":22},"风机联动启动后，测得第三层楼梯间前室上与走道之间的压差值为40Pa","ABC",{"id":451,"libraryId":5,"type":105,"typeLabel":106,"stem":452,"options":453,"answer":449,"analysis":33},935110,"(2018年真题) 防工程施工单位对安装在某大厦地下车库的机械排烟系统进行系统联动调试。下列调试方法和结果中，符合现行国家标准《建筑防烟排烟系统技术标准》(GB51251)的有（ ）。",[454,456,458,460,462],{"key":20,"text":455,"correct":26},"手动开启任一常闭排烟口，相应的排烟风机联动启动",{"key":24,"text":457,"correct":26},"模拟火灾报警后12s相应的排烟口、排烟风机联动启动",{"key":28,"text":459,"correct":26},"补风机启动后，在补风囗处测得的风速为8m\u002Fs",{"key":31,"text":461,"correct":22},"模拟火灾报警后20s相应的补风机联动启动",{"key":118,"text":463,"correct":22},"排烟风机启动后，在排烟口处测得的风速为12m\u002Fs",{"id":465,"libraryId":5,"type":105,"typeLabel":106,"stem":466,"options":467,"answer":478,"analysis":33},935111,"(2016年真题) 某12层公共建筑，防烟楼梯间及其合用前室采用正压送风系统，正压风机设置在屋顶，消防设施检测机构对该建筑物的正压送风系统进行检测，结果;十一层送风量满足设计值，五层正压送风量满足设计值，五层正压送风量为设计风值的80%，二层正风送风量为设计风值的60%，造成这一结果的可能原因是（??）",[468,470,472,474,476],{"key":20,"text":469,"correct":26},"风机风量压力不足",{"key":24,"text":471,"correct":22},"风道尺寸偏小",{"key":28,"text":473,"correct":22},"部件造型不当",{"key":31,"text":475,"correct":26},"风道泄露风口",{"key":118,"text":477,"correct":22},"位置不当","AD",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":20,"analysis":33},935112,"(2017年真题)在防排烟系统中，系统组件在正常工作状态下的启闭状态是不同的，关于防排烟系统组件启闭状态的说法中，正确的是（??）",[483,485,487,489],{"key":20,"text":484,"correct":26},"加压送风口既有常开式，也有常闭式",{"key":24,"text":486,"correct":22},"排烟防火阀及排烟阀平时均呈开启状态",{"key":28,"text":488,"correct":22},"排烟防火阀及排烟阀平时均呈关闭状态",{"key":31,"text":490,"correct":22},"自垂百叶式加压送风口平时呈开启状态",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":20,"analysis":33},935113,"(2017年真题)下列建筑防排烟系统周期性检查维护项目中，不属于每月检查项目的是（??）",[495,497,499,501],{"key":20,"text":496,"correct":26},"风机流量压力性能测试",{"key":24,"text":498,"correct":22},"排烟风机手动启停",{"key":28,"text":500,"correct":22},"挡烟垂壁启动复位",{"key":31,"text":502,"correct":22},"排烟风机自动启动",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":31,"analysis":33},935114,"(2017年真题)对某公共建筑防排烟系统设置情况进行检查。下列检查结果中，不符合现行国家消防技术标准要求的是（??）",[507,509,511,513],{"key":20,"text":508,"correct":22},"地下一层长度为20m的疏散走道未设置排烟设施",{"key":24,"text":510,"correct":22},"地下一层1个50m2的仓库内未设置排烟设施",{"key":28,"text":512,"correct":22},"四层1个50m2的会议室内未设置排烟设施",{"key":31,"text":514,"correct":26},"四层1个50m2游戏室内未设置排烟设施",{"id":516,"libraryId":5,"type":105,"typeLabel":106,"stem":517,"options":518,"answer":529,"analysis":33},935115,"(2017年真题)消防设施检测机构对某建筑的机械排烟系统进行检测时,打开排烟阀,消防控制室接到风机启动的反馈信号,现场测量,排烟口入口处排烟风速过低,可能原因有(??)",[519,521,523,525,527],{"key":20,"text":520,"correct":22},"风机反转",{"key":24,"text":522,"correct":26},"风道阻力过大",{"key":28,"text":524,"correct":22},"风口尺寸偏小",{"key":31,"text":526,"correct":22},"风机位置不当",{"key":118,"text":528,"correct":26},"风道漏风量过大","BE",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":31,"analysis":33},935116,"(2018年真题)对某大厦设置的机械防烟系统的正压送风机进行单机调试，下列调试方法和结果中，符合现行国家标准《建筑防烟排烟系统技术标准》(GB51251)的是()。",[534,536,538,540],{"key":20,"text":535,"correct":22},"模拟火灾报警后，相应防烟分区的正压送风口打开并联动正压送风机启动",{"key":24,"text":537,"correct":22},"经现场测定，正压送风机的风量值、风压值分别为风机铭牌的 97%、105%",{"key":28,"text":539,"correct":22},"在消防控制室远程手动启、停正压送风机，风机启动、停止功能正常",{"key":31,"text":541,"correct":26},"手动开启正压送风机，风机正常运转 1.0h 后，手动停止风机",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":28,"analysis":33},935117,"(2018年真题)对某大型超市设置的机械排烟系统进行验收，其中两个防烟分区的验收测试结果中，符合现行国家标准《建筑防烟排烟系统技术标准》（GB51251）的是（ ）。",[546,548,550,552],{"key":20,"text":547,"correct":22},"开启防烟分区一的全部排烟口，排烟风机启动后测试排烟口处的风速为 13m／s",{"key":24,"text":549,"correct":22},"开启防烟分区一的全部排烟口，补风机启动后测试补风口处的风速为 9m／s",{"key":28,"text":551,"correct":26},"开启防烟分区二的全部排烟口，排烟风机启动后测试排烟口处的风速为 8m／s",{"key":31,"text":553,"correct":22},"开启防烟分区二的全部排烟口，补风机启动后测试补风口处的风速为 7m／s",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":24,"analysis":33},935118,"(2018年真题)某二类高层建筑设有独立的机械排烟系统，该机械排烟系统的组件可不包括（ ）。",[558,560,562,564],{"key":20,"text":559,"correct":22},"在 280℃的环境条件下能够连续工作 30min 的排烟风机",{"key":24,"text":561,"correct":26},"动作温度为 70℃的防火阀",{"key":28,"text":563,"correct":22},"采取了隔热防火措施的镀锌钢板风道",{"key":31,"text":565,"correct":22},"可手动和电动启动的常闭排烟口",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":31,"analysis":33},935119,"(2018年真题)某建筑进行防火检查，防烟分区的活动挡烟垂壁的下列检查结果中，不符合现行国家标准要求是( )",[570,572,574,576],{"key":20,"text":571,"correct":22},"采用厚度为 1.00mm 的金属板材作挡烟垂壁",{"key":24,"text":573,"correct":22},"挡烟垂壁的单节宽度为 2m",{"key":28,"text":575,"correct":22},"挡烟垂壁的实际挡烟高度为 600mm",{"key":31,"text":577,"correct":26},"挡烟垂壁附近的感温火灾探测器的报警信号作为挡烟垂壁的联动触发信号",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":28,"analysis":33},935120,"(2016年真题) 对建筑防排烟系统验收时，验收包含资料验收，外观质量检查、系统功能测试和合格判定等四部分内容，下列文件资料中，不属于资料验收内容的是（?）",[582,584,586,588],{"key":20,"text":583,"correct":22},"施工图等设计文件",{"key":24,"text":585,"correct":22},"联动调试记录表",{"key":28,"text":587,"correct":26},"立项批准文件",{"key":31,"text":589,"correct":22},"风管系统安装及检查记录",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":28,"analysis":33},935121,"(2016年真题) 防排阀系统施工安装前，对风管部件进行现场检验时，下列检查项目中，不属于现场检查项目的是 （?）。",[594,596,598,600],{"key":20,"text":595,"correct":22},"电动防火阀",{"key":24,"text":597,"correct":22},"送风口",{"key":28,"text":599,"correct":26},"正压送风机",{"key":31,"text":601,"correct":22},"柔性短管",{"id":603,"libraryId":5,"type":15,"typeLabel":16,"stem":604,"options":605,"answer":31,"analysis":33},935122,"(2016年真题)建筑防排烟系统运行周期性维护管理中，下列检查项目中不属于每半年检查项目的是（??）",[606,608,610,612],{"key":20,"text":607,"correct":22},"防火阀",{"key":24,"text":609,"correct":22},"排烟口",{"key":28,"text":611,"correct":22},"送风口（阀）",{"key":31,"text":613,"correct":26},"联动功能",{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":24,"analysis":33},935123,"(2016年真题) 某建筑的排烟系统采用活动式挡烟垂壁，按现行国家标准和系统使用功能以及质量要求进行施工。下列工作中，不属于挡烟垂壁安装工作的是（??）。",[618,620,622,624],{"key":20,"text":619,"correct":22},"挡烟垂壁与建筑主体结构安装固定",{"key":24,"text":621,"correct":26},"模拟火灾时挡烟垂壁动作功能",{"key":28,"text":623,"correct":22},"挡烟垂壁之间的缝隙衔接控制",{"key":31,"text":625,"correct":22},"挡烟垂壁与建筑主体之间的缝隙控制",{"id":627,"libraryId":5,"type":15,"typeLabel":16,"stem":628,"options":629,"answer":28,"analysis":33},935124,"(2015年真题) 某商场消防设施维护管理人员对商场设置的防烟排烟系统进行日常巡查。下列内容中，不属于防烟排烟系统日常巡查的是（）。",[630,632,634,636],{"key":20,"text":631,"correct":22},"每天检查送风机、排烟风机及其控制柜的外观及工作状态",{"key":24,"text":633,"correct":22},"每天检查挡烟垂壁及其控制装置外观及工作状态",{"key":28,"text":635,"correct":26},"每天检查送风阀、排烟阀联动启动送风机、排烟风机的功能",{"key":31,"text":637,"correct":22},"每天检查电动排烟窗，自然排烟设施的外观",{"id":639,"libraryId":5,"type":105,"typeLabel":106,"stem":640,"options":641,"answer":652,"analysis":33},935125,"（2020年真题）某消防技术服务机构对某建筑内设置的防烟排烟系统下列检查结果中，符合标准《建筑防烟排烟系统技术标准》（GB51251）的有（ ）。",[642,644,646,648,650],{"key":20,"text":643,"correct":26},"吊顶内的排烟管道采用玻璃棉隔热，与可燃物的最小距离为200mm",{"key":24,"text":645,"correct":22},"房间内排烟口距可燃物的最小距离为1.1m",{"key":28,"text":647,"correct":26},"风管穿越隔墙处，风管与隔墙之间的空隙采用水泥砂浆封堵",{"key":31,"text":649,"correct":26},"排烟风机直接安装在混凝土基础上，未设置减振装置",{"key":118,"text":651,"correct":22},"排烟风机安装在专用房间内，排烟风机外壳与墙壁之间的距离为0.5m","ACD",[654,657,660,663,666,669],{"id":15,"name":655,"category":7,"favorite":656},"领导干部任职前廉政法规知识测试题",92,{"id":658,"name":659,"category":7,"favorite":15},595,"建筑结构与设备",{"id":661,"name":662,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":664,"name":665,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":667,"name":668,"category":7,"favorite":8},534,"BIM工程师",{"id":670,"name":668,"category":7,"favorite":8},535]