[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":635},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,8,50,2974,[13,34,46,58,70,82,94,106,124,136,148,163,175,190,205,217,232,244,256,268,280,292,300,312,320,332,344,356,368,380,395,407,419,431,443,455,467,479,491,503,515,527,539,551,563,575,587,599,611,623],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},935025,1,"单选题","（2020年真题）某企业柴油发电机房设有水喷雾灭火系统，根据现行国家标准《水喷雾灭火系统技术规范》（GB 50219），对该水喷露灭火系统的雨淋报警阀组进行调试时，不需要使用到的检测工具是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","微压计",true,{"key":24,"text":25,"correct":26},"B","流量计",false,{"key":28,"text":29,"correct":26},"C","秒表",{"key":31,"text":32,"correct":26},"D","声强计","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},935026,"（2019年真题）某电信大楼安装细水雾灭火系统，系统的设计工作压力为10.0MPa。根据现行国家标准《细水雾灭火系统技术规范》(GB50898)，该系统调试的下列做法和结果中，不符合规范要求的是（）",[38,40,42,44],{"key":20,"text":39,"correct":22},"柴油泵作为备用泵，柴油泵的启动时间为10s",{"key":24,"text":41,"correct":26},"制定系统调试方案，根据批准的方案按程序进行系统调试",{"key":28,"text":43,"correct":26},"对泵组、稳压泵、分区控制阀进行调试和联动试验",{"key":31,"text":45,"correct":26},"对控制柜进行空载和加载控制调试",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},935027,"(2017年真题) 某消防工程施工单位的人员在细水雾灭火系统调试过程中，对系统的泵组进行调试。根据现行国家标准《细水雾灭火系统技术规范》GB50898，下列泵组调试结果中，不符合要求的是()。",[50,52,54,56],{"key":20,"text":51,"correct":26},"以自动方式启动泵组时，泵组立即投入运行",{"key":24,"text":53,"correct":22},"以备用电源切换方式切换启动泵组时，泵组10s投入运行",{"key":28,"text":55,"correct":26},"采用柴油泵作为备用泵时，柴油泵的启动时间为5s",{"key":31,"text":57,"correct":26},"控制柜进行空载和加载控制调试时，控制柜正常动作和显示",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},935028,"(2016年真题) 在对建筑外保温系统进行防火检查时，发现的下列做法中，符合现行国家消防技术标准要求的是（??）",[62,64,66,68],{"key":20,"text":63,"correct":26},"建筑高度为20m的医院病房楼，基层墙体与装饰层之间有空腔，外墙外保温系统采用燃烧性能为B2级的保温材料",{"key":24,"text":65,"correct":22},"建筑高度27m的住宅楼，基层墙体与装饰层之间无空腔，外墙外保温系统采用燃烧性能为B2级的保温材料",{"key":28,"text":67,"correct":26},"建筑高度15m的员工集体宿舍基层墙体与装饰层之间无空腔，外墙外保温系统采用燃烧性能为B1级的保温村料",{"key":31,"text":69,"correct":26},"建筑高度为18m的办公楼，基层墙体与装饰层之间有空腔，外墙外保温系统采用燃烧性能为B2级的保温材料",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},935029,"(2018年真题)对某电信大楼安装的细水雾灭火系统进行系统验收，根据现行国家标准《细水雾灭火系统技术规范》(GB 50898)，下列检测结果中，属于工程质量缺陷项目一般缺陷项的是( )",[74,76,78,80],{"key":20,"text":75,"correct":26},"资料中缺少系统及其主要组件的安装使用和维护说明书",{"key":24,"text":77,"correct":26},"水质不符合设计规定的标准",{"key":28,"text":79,"correct":22},"水泵的流量为设计流量的 90%",{"key":31,"text":81,"correct":26},"安装的管道支架间距为设计要求的 120%",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},935030,"(2016年真题) 细水雾灭火系统喷头的安装，应在管道安装完毕，试压、吹扫合格后进行。 喷头与管道连接处的 密封材料宜采用（??）",[86,88,90,92],{"key":20,"text":87,"correct":26},"聚四氟乙烯",{"key":24,"text":89,"correct":26},"麻丝",{"key":28,"text":91,"correct":26},"粘结剂",{"key":31,"text":93,"correct":22},"O型密封圈",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},935031,"（2020年真题）某消防技术服务机构对某机房内设置的1套全淹没开式细水雾灭火系统进行了防火检查。下列检查结果中，不符合现行国家标准《细水雾灭火系统技术规范》（GB 50898）的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"分区控制阀为常闭信号阀，安装在防护区内",{"key":24,"text":101,"correct":26},"该系统保护的防护区数量为2个",{"key":28,"text":103,"correct":26},"系统管道之间采用氩弧焊工艺对口焊接",{"key":31,"text":105,"correct":26},"泵组吸水管上的变径处采用偏心大小头",{"id":107,"libraryId":5,"type":108,"typeLabel":109,"stem":110,"options":111,"answer":123,"analysis":33},935032,2,"多选题","(2015年真题) 消防技术服务机构对某电视发射塔安装的IG541混合气体灭火系统进行验收前检测。在模拟启动试验环节，正确的检测方法有（）。",[112,114,116,118,120],{"key":20,"text":113,"correct":22},"手动模拟启动试验时，按下手动启动按钮，观察相关声光报警系统及启动输出端负载的动作信号、联动设备动作是否正常。",{"key":24,"text":115,"correct":22},"手动模拟启动试验时，使压力信号反馈装置动作，观察相关防护区门外的气体喷放指示灯动作是否正常",{"key":28,"text":117,"correct":22},"自动模拟启动试验时，用人工模拟火警使防护区内的任一火灾探测器动作，观察火警信号输出后，相关报警设备动作是否正常；再用人工模拟火警使防护区内的另一火灾探测器动作，观察相关声光报警及启动输出端负载的动作信号、联动设备动作是否正常",{"key":31,"text":119,"correct":22},"可用一个与灭火系统驱动装置启动电压、电流相同的负载代替灭火系统驱动装置进行模拟启动试验",{"key":121,"text":122,"correct":26},"E","手动模拟启动试验与自动模拟启动试验任选一项即可","ABCD",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":20,"analysis":33},935033,"（2019年真题）常用检验仪器包括:(1)称重器;(2)压力表;(3)液位仪;(4)流量计。上述4种检验仪器中，可适用于低压二氧化碳灭火系统灭火剂泄漏检查的仪器共有（）",[128,130,132,134],{"key":20,"text":129,"correct":22},"1种",{"key":24,"text":131,"correct":26},"3种",{"key":28,"text":133,"correct":26},"2种",{"key":31,"text":135,"correct":26},"4种",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":28,"analysis":33},935034,"（2019年真题）根据现行国家规定《气体灭火系统施工及验收规范》(GB50263)，关于低压二氧化碳灭火系统管道强度试验及气密性试验的说法，正确的是（）。",[140,142,144,146],{"key":20,"text":141,"correct":26},"管道气压强度试验压力应为设计压力的1.5倍",{"key":24,"text":143,"correct":26},"气密性试验前应进行吹扫，吹扫时管道末端的气体流速不应小于10m\u002Fs",{"key":28,"text":145,"correct":22},"经气压强度试验合格且在试验后未拆卸过的管道可不进行气密性试验",{"key":31,"text":147,"correct":26},"采用气压强度试验代替水压强度试验时，试验压力应为60%水压强度试验",{"id":149,"libraryId":5,"type":108,"typeLabel":109,"stem":150,"options":151,"answer":162,"analysis":33},935035,"（2019年真题）某地下档案库房，设置了全淹没二氧化碳灭火系统，对该气体灭火系统的防护区进行防火检查，下列检查结果中，不符合现行国家标准要求的有（）",[152,154,156,158,160],{"key":20,"text":153,"correct":26},"防护区入口附近未设置气体灭火控制盘",{"key":24,"text":155,"correct":22},"防护区的入口处明显位置未配置专用的空气呼吸器或氧气呼吸器",{"key":28,"text":157,"correct":22},"防护区内未设置机械排风装置",{"key":31,"text":159,"correct":26},"系统管道未设置防静电接地",{"key":121,"text":161,"correct":22},"防护区出入口未设手动、自动转换装置","BCE",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":31,"analysis":33},935036,"(2017年真题) 某气体灭火系统储罐瓶间内设有6只150L七氟丙烷灭火剂储存容器，根据现行国家标准《气体灭火系统施工及验收规范》GB50263，各储存容器的高度差最大不宜超过（??）mm",[167,169,171,173],{"key":20,"text":168,"correct":26},"10",{"key":24,"text":170,"correct":26},"30",{"key":28,"text":172,"correct":26},"50",{"key":31,"text":174,"correct":22},"20",{"id":176,"libraryId":5,"type":108,"typeLabel":109,"stem":177,"options":178,"answer":189,"analysis":33},935037,"(2017年真题) 某单位的图书馆书库采用无管网七氟丙炕气体灭火装置进行防护， 委托消防检查机构对该气体灭火系统进行检测。 下列检测结果中， 符合现行国家消防技术标准要求的有（??）。",[179,181,183,185,187],{"key":20,"text":180,"correct":22},"系统仅设置自动控制、 手动控制两种启动方式",{"key":24,"text":182,"correct":22},"防护区内设置10台预制灭火装置",{"key":28,"text":184,"correct":26},"防护区门口未设手动与自动控制的转换装置",{"key":31,"text":186,"correct":26},"储存容器的充装压力为4.2MPa",{"key":121,"text":188,"correct":26},"气体灭火系统采用自动控制方式","AB",{"id":191,"libraryId":5,"type":108,"typeLabel":109,"stem":192,"options":193,"answer":204,"analysis":33},935038,"(2018年真题) 某单位计算机房位于地下一层，净空高度为4.5m，采用单元独立式IG541气体灭火系统进行防护，灭火剂设计储存压力为20MPa。消防技术服务机构对该气体灭火系统进行检测。下列检测结果中，符合现行国家标准要求的有( )。",[194,196,198,200,202],{"key":20,"text":195,"correct":22},"灭火剂储存容器上安全泄压装置的动作压力为28MPa",{"key":24,"text":197,"correct":26},"低泄高封阀安装在驱动气体管道的末端",{"key":28,"text":199,"correct":26},"防护区内设置机械排风装置，其通风换气次数为每小时3次",{"key":31,"text":201,"correct":26},"80L灭火剂储存容器内的灭火剂储存量为19.5kg",{"key":121,"text":203,"correct":22},"泄压口距地面高度为2.9m","AE",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":24,"analysis":33},935039,"(2018年真题) 某计算机房设置组合分配式七氟丙烷气体灭火系统，最大防护区的灭火剂存储容器数量为 6 个，规格为 120L。 对该防护区进行系统模拟喷气试验。关于该防护区模拟试验的说法，正确的是（??）",[209,211,213,215],{"key":20,"text":210,"correct":26},"试验时，应采用其充装的灭火剂进行模拟喷气试验",{"key":24,"text":212,"correct":22},"试验时，模拟喷气用灭火剂存储容器的数量最少为 2 个",{"key":28,"text":214,"correct":26},"试验时，可选用规格为 150L 的灭火剂存储容器进行模拟喷气试验",{"key":31,"text":216,"correct":26},"试验时，喷气试验宜采用手动启动方式",{"id":218,"libraryId":5,"type":108,"typeLabel":109,"stem":219,"options":220,"answer":231,"analysis":33},935040,"(2016年真题)某电信大楼设备机房设置气体灭火系统，有3个相同的防护区，采用IG541气体灭火系统进行防护，防护区吊顶为活动吊顶下方空间分别设置一套组合分配系统，下列检查结论中，正确的有（?）",[221,223,225,227,229],{"key":20,"text":222,"correct":22},"防护区吊顶上方空间与吊顶下方空间的设计浓度相同，符合规范要求",{"key":24,"text":224,"correct":22},"防护区吊顶上方空间与吊顶下方空间的喷头时间相同，符合规范要求",{"key":28,"text":226,"correct":26},"防护区泄压口的安装高度低于防护区净高的2\u002F3,不符合规范要求",{"key":31,"text":228,"correct":26},"两套系统分别设置启动装置，同一防护去吊顶上方空间与吊顶下方空间的启动装置同时启动，符合规范要求",{"key":121,"text":230,"correct":22},"两个集流管上的储存容器规格及充装压力分布为90L，15MPa和70L.15MPa,符合规范要求","ABE",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":28,"analysis":33},935041,"(2017年真题)某七氟丙烷气体灭火系统防护区的灭火剂储存容器，在20℃时容器内压力为2.5MPa,50℃时的容器内压力为4.2Mpa，对该防护区灭火剂输送管道采用气压强度试验代替水压强度试验时，最小试验压力应为（??）MPa",[236,238,240,242],{"key":20,"text":237,"correct":26},"3.75",{"key":24,"text":239,"correct":26},"4.62",{"key":28,"text":241,"correct":22},"4.83",{"key":31,"text":243,"correct":26},"6.3",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":28,"analysis":33},935042,"(2017年真题)关于气体灭火系统维护管理周期检查项目的说法，错误的是（??）。",[248,250,252,254],{"key":20,"text":249,"correct":26},"每日应检查低压二氧化碳储存装置的运行情况和储存装置间的设备状态",{"key":24,"text":251,"correct":26},"每月应检查预制灭火系统的设备状态和运行状况",{"key":28,"text":253,"correct":22},"每年应对选定的防护区进行1次模拟启动试验",{"key":31,"text":255,"correct":26},"每月应检查低压二氧化碳灭火系统储存装置的液位计",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":28,"analysis":33},935043,"(2018年真题)单位管理人员对低压二氧化碳灭火系统进行巡查，根据现行国家标准《建筑消防设施的维护管理》（GB25201），不属于该系统巡查内容的是（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":26},"气体灭火控制器的工作状态",{"key":24,"text":263,"correct":26},"低压二氧化碳系统安全阀的外观",{"key":28,"text":265,"correct":22},"低压二氧化碳储存装置内灭火剂的液位",{"key":31,"text":267,"correct":26},"低压二氧化碳系统制冷装置的运行状况",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":31,"analysis":33},935044,"(2018年真题)某高低压配电间设置组合分配式七氟丙烷气体灭火系统，防护区数量为2个，1个防护区的灭火剂用量是另一个防护区的两倍，系统驱动装置由驱动气体瓶组及电磁阀等组成，为实现该气体灭火系统的启动控制功能，驱动气体管道上设置的气流单向阀最少应为（ ）",[272,274,276,278],{"key":20,"text":273,"correct":26},"0个",{"key":24,"text":275,"correct":26},"1个",{"key":28,"text":277,"correct":26},"3个",{"key":31,"text":279,"correct":22},"2个",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":33},935045,"(2016年真题) 根据《气体灭火系统施工及验收规范》GB50263，安装气体灭火系统气动驱动装置的管道时，水平管道采用管卡固定，管卡的间距不宜大于（）m，转弯处，应增设1个管卡。",[284,286,288,290],{"key":20,"text":285,"correct":22},"0.6",{"key":24,"text":287,"correct":26},"0.5",{"key":28,"text":289,"correct":26},"0.7",{"key":31,"text":291,"correct":26},"0.8",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":20,"analysis":33},935046,"(2017年真题) 某七氟丙烷气体灭火系统防护区的灭火剂储存容器，在20℃时容器内压力为2.5MPa，50℃是的容器内压力为4.2MPa。对该防护区灭火剂输送管道采用气压强度试验代替水压强度试验时，最小试验压力应为()MPa。",[296,297,298,299],{"key":20,"text":241,"correct":22},{"key":24,"text":237,"correct":26},{"key":28,"text":239,"correct":26},{"key":31,"text":243,"correct":26},{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":24,"analysis":33},935047,"(2016年真题)某建筑的电子计算机房采用气体灭火系统保护，在一个防护区内安装了3台预制灭火装置，根据《气体灭火系统设计规范》GB50370，3台预制灭火装置动作响应时差最大不得大于（??）s",[304,306,308,310],{"key":20,"text":305,"correct":26},"1",{"key":24,"text":307,"correct":22},"2",{"key":28,"text":309,"correct":26},"3",{"key":31,"text":311,"correct":26},"4",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":24,"analysis":33},935048,"(2016年真题)根据?《气体灭火系统施工及验收规范》GB50263，安装气体灭火系统气动驱动装置的管道时，水平管道应采用管卡固定，管卡的间距不宜大于（??）m，转弯处应增设1个管卡",[316,317,318,319],{"key":20,"text":287,"correct":26},{"key":24,"text":285,"correct":22},{"key":28,"text":289,"correct":26},{"key":31,"text":291,"correct":26},{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":322,"options":323,"answer":28,"analysis":33},935049,"(2016年真题)对气体灭火系统进行维护保养，应定期对系统功能进行测试。下列关于模拟喷气试验的说法中，错误的是（??）",[324,326,328,330],{"key":20,"text":325,"correct":26},"每年应对防护区进行一次模拟喷气试验",{"key":24,"text":327,"correct":26},"10%混合气体灭火系统应采用其充装的灭火剂进行模拟喷气试验",{"key":28,"text":329,"correct":22},"七氟丙烷系统模拟喷气实验时，试验瓶的数量不应小于灭火剂储存容器数的10%，且不少于1个",{"key":31,"text":331,"correct":26},"高压二氧化碳灭火系统应采用其充装的灭火剂进行模拟喷气试验",{"id":333,"libraryId":5,"type":15,"typeLabel":16,"stem":334,"options":335,"answer":24,"analysis":33},935050,"(2016年真题)消防检测机构对某单位安装的干粉预制灭火装置进行检测，下列检测结果中，不符合现行国家消防技术标准规定的是（??）",[336,338,340,342],{"key":20,"text":337,"correct":26},"管道长度为18m",{"key":24,"text":339,"correct":22},"灭火剂储存量为160KG",{"key":28,"text":341,"correct":26},"工作压力2.3MPa",{"key":31,"text":343,"correct":26},"一个防护区使用3套预制灭火装置",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":20,"analysis":33},935051,"(2015年真题) 下列关于气体灭火系统灭火剂输送管道强度试验与气密性试验的说法中，正确的是（）",[348,350,352,354],{"key":20,"text":349,"correct":22},"经气体强度试验合格且在试验后未拆卸过的管道可不进行气密性试验",{"key":24,"text":351,"correct":26},"IG541混合气体灭火剂输送管道的气密性试验压力与气压强度试验压力相差无几，故可只做气密性试验",{"key":28,"text":353,"correct":26},"气压强度试验或气密性试验的加压介质可采用空气、二氧化碳或氮气",{"key":31,"text":355,"correct":26},"同时具备水压强度试验与气压强度试验条件时，可选择任一方式进行试验",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":24,"analysis":33},935052,"(2015年真题) 下列关于气体灭火系统维护管理的说法中，正确的是（）。",[360,362,364,366],{"key":20,"text":361,"correct":26},"气体灭火系统的储存器应定期抽样送国家级消防产品检验中心检验",{"key":24,"text":363,"correct":22},"应按《气瓶安全监察规程》的规定对气体灭火系统使用的钢瓶进行维护保养",{"key":28,"text":365,"correct":26},"每两个季度应对高压二氧化碳储存容器逐个进行称重检查",{"key":31,"text":367,"correct":26},"发现七氟丙烷灭火系统储存容器内的压力低于额定工作压力时，应立即使用氮气增压",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":28,"analysis":33},935053,"(2015年真题) 下列关于气体灭火系统功能验收的说法中，错误的是（）。",[372,374,376,378],{"key":20,"text":373,"correct":26},"设有灭火剂备用量的系统，必须进行模拟切换操作试验且合格",{"key":24,"text":375,"correct":26},"柜式气体灭火装置进行模拟喷气试验时，宜采用自动启动方式且合格",{"key":28,"text":377,"correct":22},"使用高压氮气启动选择阀的二氧化碳灭火系统，选择阀必须在容器阀动作之后或同时打开",{"key":31,"text":379,"correct":26},"气体灭火系统功能验收时，应按规范要求进行主、备电源切换试验并合格",{"id":381,"libraryId":5,"type":108,"typeLabel":109,"stem":382,"options":383,"answer":394,"analysis":33},935054,"（2020年真题）某高层建筑内的高低压配电室采用七氟丙烷气体灭火系统进行防护，最大防护区灭火剂设计用量为705kg，储瓶间内设置6个150L灭火剂瓶，灭火剂充装密度为800kg\u002Fm3。根据现行国家标准《气体灭火系统施工及验收规范》（GB50263，对该气体灭火系统进行系统功能验收时，应做的试验项目有（ ）",[384,386,388,390,392],{"key":20,"text":385,"correct":22},"模拟启动实验",{"key":24,"text":387,"correct":22},"模拟喷气实验",{"key":28,"text":389,"correct":22},"主用备用电源切换试验",{"key":31,"text":391,"correct":26},"主用备用灭火器触屏模拟切换操作试验",{"key":121,"text":393,"correct":26},"手动应急启动装置动作试验","ABC",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":24,"analysis":33},935055,"（2020年真题）根据现行国家标准《气体灭火系统施工及验收规范》（GB50263），关于气体灭火系统维护管理检查周期的说法，正确的是（ ）。",[399,401,403,405],{"key":20,"text":400,"correct":26},"每周应检查低压二氧化碳灭火系统储存装置的运行情况",{"key":24,"text":402,"correct":22},"每月应检查七氟丙烷管网灭火系统灭火剂储存容器内的压力",{"key":28,"text":404,"correct":26},"每半年应检查IG541气体灭火系统全部系统组件的碰撞变形及机械性损伤情况",{"key":31,"text":406,"correct":26},"每半年应对高压二氧化碳灭火系统储存容器逐个进行称重检查",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":28,"analysis":33},935056,"（2020年真题）某计算机房采用IG541气体灭火系统进行防护，灭火剂设计充装压力为15MPa，驱动气体为氮气，设计储存压力为6.0MPa。系统设备安装前进行进场检验，检验时的环境温度为10°℃，根据现行国家标准《气体灭火系统施工及验收规范》（GB50263），下列检测结果中，不符合规范要求的是（ ）。",[411,413,415,417],{"key":20,"text":412,"correct":26},"灭火剂储瓶内的压力值为14.3MPa",{"key":24,"text":414,"correct":26},"灭火剂储瓶的高度差最大为15mm",{"key":28,"text":416,"correct":22},"驱动气体储瓶内的压力值为5.5MPa",{"key":31,"text":418,"correct":26},"驱动气体储瓶的高度差最大为10mm",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":28,"analysis":33},935057,"（2020年真题）下列对高压二氧化碳灭火系统管道气密性试验的方法和结果判定中，不符合现行国家标准《气体灭火系统施工及验收规范》（GB 50263）的是（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":26},"进行气密性试验时，压力升至规范要求的试验压力值用时119s",{"key":24,"text":426,"correct":26},"达到规范要求的试验压力后，关断试验气源，3min内压力下降不超过试验压力的10%",{"key":28,"text":428,"correct":22},"灭火剂输送管道的气密性试验介质为空气，试验压力为8.8MPa",{"key":31,"text":430,"correct":26},"气动管道的气密性试验压力为驱动气体储存压力的1倍",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":31,"analysis":33},935058,"（2019年真题）某单位石油泡沫灭火系统，某单位设有泡沫灭火系统，系统设置及系统各项性能参数均符合现行国家标准要求。该泡沫灭火系统发泡倍数的测量参数为;量桶空桶重量为2κg，量桶装满清水重量为32kg，量桶装满泡沫重量为12kg。该泡沫灭火系统的形式最有可能的是（）。",[435,437,439,441],{"key":20,"text":436,"correct":26},"低倍数液上喷射泡沫灭火系统",{"key":24,"text":438,"correct":26},"中倍数泡沬灭火系统",{"key":28,"text":440,"correct":26},"高倍数泡沫灭火系统",{"key":31,"text":442,"correct":22},"低倍数液下喷射泡沫灭火系统",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":31,"analysis":33},935059,"（2019年真题）某消防工程施工单位对某石化企业原油储罐区安装的低倍数泡沫自动灭火系统进行系统调试，下列喷水试验的测试方法中，符合现行国家标准《泡沫灭火系统施工及验收规范》(GB50281)要求的是（）",[447,449,451,453],{"key":20,"text":448,"correct":26},"选择最近和最大的两个储罐以手动控制方式分别进行2次喷水试验",{"key":24,"text":450,"correct":26},"选择最远和最大的两个储罐以自动控制方式分别进行2次喷水试验",{"key":28,"text":452,"correct":26},"选择最近和最大的两个储罐以手动和自动控制方式分别进行1次喷水试验",{"key":31,"text":454,"correct":22},"选择最远和最大的两个储罐以手动和自动控制方式分别进行1次喷水试验",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":24,"analysis":33},935060,"（2019年真题）某企业厂区内1个容积为2000㎡的可燃液体储罐,按现行囯家标准《建筑设施防火规范》(G50016)的要求设置了泡沫灭火系统,（）不是该泡沫灭火系统的构成组件。",[459,461,463,465],{"key":20,"text":460,"correct":26},"泡沫产生器",{"key":24,"text":462,"correct":22},"消防水带",{"key":28,"text":464,"correct":26},"泡沫比例混合器",{"key":31,"text":466,"correct":26},"泡沫泵",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":20,"analysis":33},935061,"（2019年真题）下列低倍数泡沫灭火系统维护保养的做法，符合现行国家标准《泡沫灭火系统施工及验收规范》(GB50281)要求的是（）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"每年对泡沫灭火系统进行一次喷泡沫试验",{"key":24,"text":474,"correct":26},"每月以手动控制方式对消防泵进行一次启动试验",{"key":28,"text":476,"correct":26},"每半年对泡沫产生器和泡沫比例混合器进行一次外观检查",{"key":31,"text":478,"correct":26},"每年对泡沫灭火系统的全部管道进行一次冲洗，清除锈渣",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":31,"analysis":33},935062,"(2017年真题) 某化工企业的立式甲醇储罐采用液上喷射低倍数泡沫灭火系统，某消防设施检测机构对该系统进行检测，下列检测结果中，不符合现行国家消防技术标准要求的是（??）",[483,485,487,489],{"key":20,"text":484,"correct":26},"泡沫泵启动后3.1min泡沫产生器喷出泡沫",{"key":24,"text":486,"correct":26},"自动喷泡沫试验，喷射泡沫时间为1min",{"key":28,"text":488,"correct":26},"泡沫混合液的发泡倍数为10倍",{"key":31,"text":490,"correct":22},"泡沫液选用水成膜泡沫液",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":20,"analysis":33},935063,"(2017年真题) 某油库采用低倍数泡沫灭火系统。根据现行国家标准《泡沫灭火系统及验收规范》（GB50281-2006），下列检查项目中，不属于每月检查一次的项目是（??）",[495,497,499,501],{"key":20,"text":496,"correct":22},"系统管道清洗",{"key":24,"text":498,"correct":26},"对储罐上的泡沫混合液立管清除锈渣",{"key":28,"text":500,"correct":26},"泡沫喷头外观检查",{"key":31,"text":502,"correct":26},"水源及水位指示装置检查",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":31,"analysis":33},935064,"(2016年真题) 某中型石油库航空煤油的立式固定顶储罐设置了低倍数泡沫灭火系统，采用水成膜泡沫液，运行几年后，消防设施检测机构对该系统进行检测与评估，下列检测结果中，不符合现行国家消防技术标准以前的有（??）",[507,509,511,513],{"key":20,"text":508,"correct":26},"泡沫混合液的连续供给时间为45min",{"key":24,"text":510,"correct":26},"泡沫混合液的发泡倍数为10",{"key":28,"text":512,"correct":26},"系统最不利点泡沫发生装置出泡沫的时间为4.6min",{"key":31,"text":514,"correct":22},"泡沫混合液的供给强度为4.7L\u002Fmin?m3",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":31,"analysis":33},935065,"(2017年真题)泡沫灭火系统的组件进入工地后，应对其进行现场检查，下列检查项目中，不属于泡沫产生器现场检查项目的是（??）",[519,521,523,525],{"key":20,"text":520,"correct":26},"表面保护涂层",{"key":24,"text":522,"correct":26},"机械性损伤",{"key":28,"text":524,"correct":26},"产品性能参数",{"key":31,"text":526,"correct":22},"严密性试验",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":24,"analysis":33},935066,"(2017年真题)对某建筑的高倍数泡沫灭火系统进行检查后得出下列结论，其中不符合现行国家消防技术标准要求的是（??）。",[531,533,535,537],{"key":20,"text":532,"correct":26},"高倍数泡沫产生器的高度应在泡沫淹没深度以上",{"key":24,"text":534,"correct":22},"高倍数泡沫产生器的出口设置导泡筒时，导泡筒的横截面面积为泡沫产生器出口横截面面积的1.2倍",{"key":28,"text":536,"correct":26},"固定安装的高倍数泡沫产生器前设置了管道过滤器、压力表和手动阀门",{"key":31,"text":538,"correct":26},"高倍数泡沫灭火系统干式水平管道最低点设置了排液阀，且坡向排液阀的管道坡度为3%",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":20,"analysis":33},935067,"(2018年真题)对某石化企业的原油储罐区安装的低倍数泡沫自动灭火系统进行喷泡沫试验。下列喷泡沫试验的方法和结果中，符合现行国家标准《泡沫灭火系统施工及验收规范》（GB 50281）的是（ ）。",[543,545,547,549],{"key":20,"text":544,"correct":22},"以自动控制方式进行 1 次喷泡沫试验，喷射泡沫的时间为 2min",{"key":24,"text":546,"correct":26},"以手动控制方式进行 1 次喷泡沫试验，喷射泡沫的时间为 1min",{"key":28,"text":548,"correct":26},"以手动控制方式进行 1 次喷泡沫试验，喷射泡沫的时间为 30s",{"key":31,"text":550,"correct":26},"以自动控制方式进行 2 次喷泡沫试验，喷射泡沫的时间为 30s",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":28,"analysis":33},935068,"(2018年真题)消防技术服务机构对某石化企业安装的低倍数泡沫灭火系统进行日常检查与维护。维保人员开展的下列检查与维护工作中，不符合现行国家标准《泡沬灭火系统施工及验收规范》(GB50281)的是( )",[555,557,559,561],{"key":20,"text":556,"correct":26},"每周以手动或自动控制方式对消防泵和备用泵进行一次启动试验",{"key":24,"text":558,"correct":26},"每月对低倍数泡沫产生器、泡沫比例混合装置、泡沫喷头等外观是否完好无损进行检查",{"key":28,"text":560,"correct":22},"每年对除储罐上泡沫混合液立管外的全部管道进行冲洗，清除锈渣",{"key":31,"text":562,"correct":26},"每两年对系统进行喷泡沫试验",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":31,"analysis":33},935069,"(2018年真题)某消防技术服务机构对某石油化工企业安装的低倍数泡沫灭火系统进行了技术检测。下列检测结果中，不符合现行国家标准《泡沫灭火系统施工及验收规范》(GB50281)的是( )。",[567,569,571,573],{"key":20,"text":568,"correct":26},"整体平衡式比例混合装置竖直安装在压水力的水平管道上",{"key":24,"text":570,"correct":26},"安装在防火堤内的水平管道坡向防火堤，坡度为 3‰",{"key":28,"text":572,"correct":26},"液下喷射的高背压泡沫产生器水平安装在防火堤外的泡沫混合液管道上",{"key":31,"text":574,"correct":22},"在防火堤外连接泡沫产生装置的泡沫混合液管道上水平安装了压力表接口",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":20,"analysis":33},935070,"(2016年真题)泡沫产生装置进场检验时，下列检查项目中，不属于外观检查项目的是（??）。",[579,581,583,585],{"key":20,"text":580,"correct":22},"材料材质",{"key":24,"text":582,"correct":26},"名牌标记",{"key":28,"text":584,"correct":26},"机械损伤",{"key":31,"text":586,"correct":26},"表面涂层",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":24,"analysis":33},935072,"(2015年真题) 泡沫灭火系统使用的常压钢制泡沫液储罐通常采用现场制作的方式，下列关于现场制作要求的说法中，正确的是（）。",[591,593,595,597],{"key":20,"text":592,"correct":26},"泡沫液管道吸液口应紧贴常压钢制泡沫液储罐底面",{"key":24,"text":594,"correct":22},"现场制作的常压钢制泡沫液储罐应进行严密性试验，试验时间应在30min以上，目测不能有泄露",{"key":28,"text":596,"correct":26},"现场制作的常压钢制泡沫液储罐，仅需对内表面进行防腐处理",{"key":31,"text":598,"correct":26},"现场制作的常压钢制泡沫液储罐的防腐处理应在严密性试验前进行",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":28,"analysis":33},935073,"(2015年真题) 在对泡沫灭火系统进行功能验收时，可用手持折射仪测量混合比的是（）。",[603,605,607,609],{"key":20,"text":604,"correct":26},"水成膜泡沫液",{"key":24,"text":606,"correct":26},"折射仪指数较小的泡沫液",{"key":28,"text":608,"correct":22},"氟蛋白泡沫液",{"key":31,"text":610,"correct":26},"抗溶水成膜泡沫液",{"id":612,"libraryId":5,"type":15,"typeLabel":16,"stem":613,"options":614,"answer":31,"analysis":33},935074,"（2020年真题）对某石化企业设置的低倍数泡沬灭火系统检测的下列结果，不符合现行国家《泡沫灭火系统施工及验收规范》（GB50281）的是（ ）.",[615,617,619,621],{"key":20,"text":616,"correct":26},"泡沫液罐操作面—侧通道的宽度为1.6m，周围检修通道的宽度为1.0m",{"key":24,"text":618,"correct":26},"泡沫比例混合器的标注方向与系统管网液流方向—致",{"key":28,"text":620,"correct":26},"穿过防火堤处的泡沫混合液管道安装了与防火堤等宽的套管，并采用防火材料对管道与套管之间的空隙进行了封堵",{"key":31,"text":622,"correct":22},"液下喷射的高背压泡沫产生器垂直安装在防火堤外的泡沫混合液管道上",{"id":624,"libraryId":5,"type":15,"typeLabel":16,"stem":625,"options":626,"answer":31,"analysis":33},935075,"（2020年真题）某高倍数泡沬灭火系统的维护保养方案中包括∶（1）灭火剂储存3年后，每年进行灭火性能检验，以确定产品是否有效;（2）每两年在防护区内进行一次喷泡沫试验;（3）每月对高倍数泡沫产生器进行一次外观检查;（4）每周对泡沫泵进行一次启动试验。上述4项维护保养要求，符合现行国家标准的有（ ）。",[627,629,631,633],{"key":20,"text":628,"correct":26},"1项",{"key":24,"text":630,"correct":26},"2项",{"key":28,"text":632,"correct":26},"3项",{"key":31,"text":634,"correct":22},"4项",[636,639,642,645,648,651],{"id":15,"name":637,"category":7,"favorite":638},"领导干部任职前廉政法规知识测试题",92,{"id":640,"name":641,"category":7,"favorite":15},595,"建筑结构与设备",{"id":643,"name":644,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":646,"name":647,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":649,"name":650,"category":7,"favorite":8},534,"BIM工程师",{"id":652,"name":650,"category":7,"favorite":8},535]