[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":647},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,7,50,2974,[13,34,52,67,79,91,103,115,127,139,154,169,181,193,205,217,229,244,256,268,280,292,307,319,330,342,354,366,378,390,402,414,426,438,453,467,479,491,503,515,527,539,551,563,575,587,599,611,623,635],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},934975,1,"单选题","(2018年真题) 根据现行国家标准《自动喷水灭火系统设计规范》 (GB 50084)，属于自动喷水灭火系统防护冷却系统组件的是（??）",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","开式洒水喷头",false,{"key":24,"text":25,"correct":26},"B","闭式洒水喷头",true,{"key":28,"text":29,"correct":22},"C","水幕喷头",{"key":31,"text":32,"correct":22},"D","雨淋报警阀组","",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":51,"analysis":33},934976,2,"多选题","(2018年真题) 对某多层旅馆设置的自动喷水灭火系统进行验收前检测，检测结果如下:（1）手动启动消防泵 29s后，水泵投入正常运行；（2）系统使用的喷头均无备用品；（3）直立型标准覆盖面积洒水喷头与端墙的距离为 2.2m；（4）水力警铃卡阻致水力警铃不报警。根据《自动喷水灭火系统施工及验收规范》（GB 50261），对该系统施工质量缺陷判定及系统验收结果判定，结论正确的有（ ）。",[40,42,44,46,48],{"key":20,"text":41,"correct":22},"检测结果中有严重缺陷 1 项",{"key":24,"text":43,"correct":22},"检测结果中有重缺陷 2 项",{"key":28,"text":45,"correct":26},"检查结果中有轻缺陷 1 项",{"key":31,"text":47,"correct":22},"该项目整体质量不合格",{"key":49,"text":50,"correct":26},"E","该项目整体质量合格","CE",{"id":53,"libraryId":5,"type":36,"typeLabel":37,"stem":54,"options":55,"answer":66,"analysis":33},934977,"(2018年真题) 某会展中心工程按照现行国家标准设计了火灾自动报警系统、自动喷水灭火系统、防排烟系统和消火栓系统等消防设施。根据《中华人民共和国消防法》，下列选择使用消防产品的要求正确的有( )。",[56,58,60,62,64],{"key":20,"text":57,"correct":26},"有国家标准的消防产品必须符合国家标准",{"key":24,"text":59,"correct":22},"优先选用专业消防设备生产厂生产的消防产品",{"key":28,"text":61,"correct":26},"没有国家标准的消防产品，必须符合行业标准",{"key":31,"text":63,"correct":22},"优先选用经技术鉴定的消防产品",{"key":49,"text":65,"correct":26},"禁止使用不合格的消防产品以及国家明令淘汰的消防产品","ACE",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":28,"analysis":33},934978,"(2018年真题) 某消防技术服务机构对某单位安装的自动喷水灭火系统进行检测，检测结果如下:(1)开启末端试水装置，以1.1L\u002Fs的流量放水，带延迟功能的水流指示器15s时动作:(2)末端试水装置安装高度为1.5m(3)最不利点末端放水试验时，自放水开始至水泵启动时间为3min(4)报警阀距地面的高度为1.2。 上述检测结果中，符合现行国家标准要求的共有()",[71,73,75,77],{"key":20,"text":72,"correct":22},"1个",{"key":24,"text":74,"correct":22},"2个",{"key":28,"text":76,"correct":26},"4个",{"key":31,"text":78,"correct":22},"3个",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":28,"analysis":33},934979,"(2016年真题) 物业管理公司对自动喷水灭火系统进行维护管理，定期巡视检查测试，根据《自动喷水灭火系统施工及验收规范》GB 50361 的要求，下列检查项目中，属于每月检查项目的是（??）。",[83,85,87,89],{"key":20,"text":84,"correct":22},"消防水源供水能力的测试",{"key":24,"text":86,"correct":22},"室外阀门井中进水管道控制阀的开启状态",{"key":28,"text":88,"correct":26},"控制阀的铅封、锁链",{"key":31,"text":90,"correct":22},"所有报警阀组的试水阀放水测试及其启动性能测试",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":28,"analysis":33},934980,"(2016年真题)对消防设施进行定期检测是消防设施维护管理工作的一项重要内容，确定自动喷水灭火系统末端试水的检测周期所依据的标准是（??）。",[95,97,99,101],{"key":20,"text":96,"correct":22},"《建筑消防设施检测技术规范》GA503",{"key":24,"text":98,"correct":22},"《建筑消防设施维护管理规定》GB25201",{"key":28,"text":100,"correct":26},"《自动喷水灭火系统施工及验收规范》GB50261",{"key":31,"text":102,"correct":22},"《自动喷水灭火系统设计规范》GB50084",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":24,"analysis":33},934981,"(2016年真题) 某工地在自动喷水灭火系统施工安装前进行进场检验，下列关于报警阀组现场检验检查项目要求中，正确的是（??）。",[107,109,111,113],{"key":20,"text":108,"correct":22},"附件配置、外观标识、外观质量、渗漏试验和强度实验等",{"key":24,"text":110,"correct":26},"附件配置、外观标识、外观质量、渗漏试验和报警阀结构等",{"key":28,"text":112,"correct":22},"阀门材质、外观标识、外观质量、渗漏试验和强度试验等",{"key":31,"text":114,"correct":22},"压力等级、外观标识、外观质量、渗漏试验和强度试验等",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":28,"analysis":33},934982,"(2016年真题) 某消防检测机构对一栋二类高层办公楼的消防给水系统进行检测。该建筑室外有两路消防进水，自动喷水灭火系统设计流量为27L\u002Fs，设计扬程为1.0MPa；室内消火栓系统设计流量为20L\u002Fs，设计扬程0.98MPa；高位消防水箱最低有效水位距最高层喷头的有效距离为10m。查验验收报告，系统所有检测合格。检测消防泵性能及其运转情况，下列检测结果中，符合现行国家消防技术标准的是（??）",[119,121,123,125],{"key":20,"text":120,"correct":22},"自动喷水泵零流量时的压力为1.5MPa",{"key":24,"text":122,"correct":22},"消火栓泵出流量25L\u002Fs时电机停止工作",{"key":28,"text":124,"correct":26},"自动喷水灭火系统最不利点末端试水装置打开5s后，流量开关发现信号启动自动喷水泵",{"key":31,"text":126,"correct":22},"室内消火栓系统试验消火栓出流量为3L\u002Fs时，消火栓泵没有启动",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":20,"analysis":33},934983,"(2016年真题) 检测建筑内自动喷水灭火系统报警阀水力警铃声强时，打开报警阀试水阀，放水流量为1.5L\u002FS，水力警铃喷嘴处压力为0.1MPa。在距离水力警铃3m处测试水力警铃声强。根据现行国家消防技术标准，警铃声强至少不应小于（??）dB。",[131,133,135,137],{"key":20,"text":132,"correct":26},"70",{"key":24,"text":134,"correct":22},"60",{"key":28,"text":136,"correct":22},"65",{"key":31,"text":138,"correct":22},"75",{"id":140,"libraryId":5,"type":36,"typeLabel":37,"stem":141,"options":142,"answer":153,"analysis":33},934984,"(2016年真题) 对自动喷水灭火系统喷头的安装情况进行检查，下列说法中，正确的有（??）",[143,145,147,149,151],{"key":20,"text":144,"correct":22},"湿式系统在吊顶下不应该安装下垂型喷头",{"key":24,"text":146,"correct":26},"喷头安装应在系统试压、冲压合格后进行",{"key":28,"text":148,"correct":22},"喷头的型号、规格、使用场所应符合规范规定",{"key":31,"text":150,"correct":26},"同一隔间内不能同时安装3mm和5mm玻璃球洒水喷头",{"key":49,"text":152,"correct":26},"水平边墙型洒水喷头濺水盘与顶板的距离不应小于150mm，且不应大于300mm","BDE",{"id":155,"libraryId":5,"type":36,"typeLabel":37,"stem":156,"options":157,"answer":168,"analysis":33},934985,"(2016年真题)某高层建筑，建筑高度50m，设有3台湿式报警阀。下列关于末端试水装置设置的说法中，正确的有（??）",[158,160,162,164,166],{"key":20,"text":159,"correct":22},"每层最不利点喷头处均应设施末端试水设置",{"key":24,"text":161,"correct":22},"末端试水装置的出流量应由系统流量系数最大的喷头确定",{"key":28,"text":163,"correct":26},"末端试水装置应由试水阀、压力表、试水接头管道",{"key":31,"text":165,"correct":26},"末端试水装置的出水应采取孔口出流的方式排入排水管道",{"key":49,"text":167,"correct":26},"末端试水装置处排水管道的直径不宜小于DN75","CDE",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":24,"analysis":33},934986,"(2017年真题)某消防工程施工单位在调试自动喷水灭火系统时，使用压力表、流量计、秒表、声强计和观察检查的方法对雨淋阀组进行调试，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB50261，关于雨淋阀组调试的说法中，正确的是（）",[173,175,177,179],{"key":20,"text":174,"correct":22},"公称直径大于200mm的雨淋阀组调试时，应在80s内启动",{"key":24,"text":176,"correct":26},"自动和手动方式启动公称直径为80mm的雨淋阀，应在15s之内启动",{"key":28,"text":178,"correct":22},"公称直径大于100mm的雨淋阀组调试时，应在30s内启动",{"key":31,"text":180,"correct":22},"当报警水压为0.15MPa时，雨淋阀的水力警铃应发出报警铃声",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":28,"analysis":33},934987,"(2017年真题)干式自动喷水灭火系统和预作用自动喷水灭火系统的配水管道上应设（ ）",[185,187,189,191],{"key":20,"text":186,"correct":22},"压力开关",{"key":24,"text":188,"correct":22},"报警阀组",{"key":28,"text":190,"correct":26},"快速排气阀",{"key":31,"text":192,"correct":22},"过滤器",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":24,"analysis":33},934988,"(2017年真题)根据现行国家标准《建筑消防设施的维护管理》GB25201，在建筑消防设施维护管理时，应对自动喷水灭火系统进行巡查并填写《建筑消防设施巡查记录表》。下列内容中，不属于自动喷水灭火系统巡查记录内容的是（??）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"报警阀组外观，试验阀门状况、排水设施状况、压力显示值",{"key":24,"text":200,"correct":26},"水流指示器外观及现场环境",{"key":28,"text":202,"correct":22},"充气设备、排气设备及控制装置等的外观及运行状况",{"key":31,"text":204,"correct":22},"系统末端试验装置外观及现场环境",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":31,"analysis":33},934989,"(2017年真题)某消防工程施工单位对自动喷水灭火系统的喷头进行安装前检查，根据现行国家标准《自动喷水灭火系统施工及验收规范》（GB50261-2005），关于喷头现场检查的说法中，错误的是（??）",[209,211,213,215],{"key":20,"text":210,"correct":22},"喷头螺纹密封面应无缺丝、断丝现象",{"key":24,"text":212,"correct":22},"喷头商标、型号等标志应齐全",{"key":28,"text":214,"correct":22},"喷头外观应无加工缺陷和机械损伤",{"key":31,"text":216,"correct":26},"每批应抽查3只喷头进行密封性能试验，且试验合格",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":24,"analysis":33},934990,"(2017年真题)某公共建筑内设置喷头1000只， 根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261-2005)，对喷淋系统进行验收时，应对现场安装的喷头规格、安装间距分别进行抽查，分别抽查的喷头数量应为（）",[221,223,225,227],{"key":20,"text":222,"correct":22},"20个、 10个",{"key":24,"text":224,"correct":26},"100个、 50个",{"key":28,"text":226,"correct":22},"25个、 10个",{"key":31,"text":228,"correct":22},"50个、 25个",{"id":230,"libraryId":5,"type":36,"typeLabel":37,"stem":231,"options":232,"answer":243,"analysis":33},934991,"(2017年真题)在自动喷水灭火系统设备和组件安装完成后应对系统进行测试， 根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261-2005)， 系统调试主控项目应包括的内容有（??）",[233,235,237,239,241],{"key":20,"text":234,"correct":22},"电动阀调试",{"key":24,"text":236,"correct":26},"水源测试",{"key":28,"text":238,"correct":26},"消防水泵调试",{"key":31,"text":240,"correct":22},"排水设施调试",{"key":49,"text":242,"correct":26},"稳压泵调试","BCE",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":24,"analysis":33},934992,"(2018年真题)根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)对自动喷水灭火系统报警阀进行调试，下列调试结果中，不符合现行国家标准要求的是( )。",[248,250,252,254],{"key":20,"text":249,"correct":22},"湿式报警阀进水口水压为0.15MPa、放水流量为1.1L\u002FS时，报警阀组及时启动",{"key":24,"text":251,"correct":26},"雨淋报警阀动作后压力开关在25s时发出动作信号",{"key":28,"text":253,"correct":22},"湿式报警阀启动后，不带延迟器的水力警铃在14s时发岀报警铃声",{"key":31,"text":255,"correct":22},"湿式报警阀启动后，带延迟器的水力警铃在85s时发出报警铃声",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":20,"analysis":33},934993,"(2018年真题)某酒店，建筑高度130m，地上38层，地下3层，消防泵房设置在地下一层，自动喷水灭火系统高区稳压泵设置在屋顶消防水箱间内。对该建筑的湿式自动喷水灭火系统进行检测。检测结果中，符合现行国家标准要求的是( )。",[260,262,264,266],{"key":20,"text":261,"correct":26},"安装在客房内管径为50mm的配水支管采用氯化聚氯乙烯管",{"key":24,"text":263,"correct":22},"高区喷淋系统报警阀组设置在1层，系统配水管道的工作压力为1.35MPa",{"key":28,"text":265,"correct":22},"高区喷淋系统末端试水装置处的压力为0.12MPa",{"key":31,"text":267,"correct":22},"末端试水装置的出水排入排水立管，排水立管管径为65mm",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":24,"analysis":33},934994,"(2018年真题)某商业综合体建筑中庭高度为15m，设置湿式自动喷水灭火系统。根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)，属于该中庭使用的喷头的进场检验内容的是( )。",[272,274,276,278],{"key":20,"text":273,"correct":22},"标准覆盖面积洒水喷头的外观",{"key":24,"text":275,"correct":26},"非仓库型特殊应用喷头的规格型号",{"key":28,"text":277,"correct":22},"扩大覆盖面积洒水喷头的响应时间指数",{"key":31,"text":279,"correct":22},"非仓库型特殊应用喷头的工作压力",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":28,"analysis":33},934995,"(2018年真题)根据现行国家标准《建筑消防设施的维护管理》（GB 25201)，属于自动喷水灭火系统巡查内容的是（??）",[284,286,288,290],{"key":20,"text":285,"correct":22},"水流指示器的外观",{"key":24,"text":287,"correct":22},"报警阀组的强度",{"key":28,"text":289,"correct":26},"喷头外观及距周边障碍物或保护对象的距离",{"key":31,"text":291,"correct":22},"压力开关是否动作",{"id":293,"libraryId":5,"type":36,"typeLabel":37,"stem":294,"options":295,"answer":306,"analysis":33},934996,"(2018年真题)根据现行国家标准《自动喷水灭火系统施工及验收规范》（GB 50261），关于自动喷水灭火系统应每月检查维护项目的说法，正确的有（）。",[296,298,300,302,304],{"key":20,"text":297,"correct":26},"每月利用末端试水装置对水流指示器进行试验",{"key":24,"text":299,"correct":22},"每月对消防水泵的供电电源进行检查",{"key":28,"text":301,"correct":26},"每月对喷头进行一次外观及备用数量检查",{"key":31,"text":303,"correct":26},"每月对消防水池，消防水箱的水位及消防气压给水设备的气体压力进行检查",{"key":49,"text":305,"correct":22},"寒冰季节，每月检查设置储水设备的房间，保持室温不低位于 5℃，任何部位不得结冰","ACD",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":28,"analysis":33},934997,"(2015年真题) 自动喷水灭火系统水流指示器的安装应在管道试压和冲洗合格后进行，在水流指示器前管道上安装的信号阀，与水流指示器之间的距离不宜小于（）mm。",[311,313,315,317],{"key":20,"text":312,"correct":22},"400",{"key":24,"text":314,"correct":22},"500",{"key":28,"text":316,"correct":26},"300",{"key":31,"text":318,"correct":22},"600",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":20,"analysis":33},934998,"(2017年真题) 某消防工程施工单位在调试自动喷水灭火系统时，使用压力表、流量计、秒表、声强计和观察检查的方法对雨淋阀组进行调试，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB50261，关于雨淋阀调试的说法中，正确的是()。",[323,325,327,329],{"key":20,"text":324,"correct":26},"自动和手动方式启动公称直径为80mm的雨淋阀，应在15s内启动",{"key":24,"text":326,"correct":22},"公称直径大于200mm的雨淋阀调试时，应在80s内启动",{"key":28,"text":328,"correct":22},"公称直径大于100mm的雨淋阀调试时，应在30s内启动",{"key":31,"text":180,"correct":22},{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},934999,"(2016年真题) 自动喷水灭火系统定期巡视检查测试时，下列关于湿式报警阀组检测试验的内容及要求的说法中，错误的是（）。",[334,336,338,340],{"key":20,"text":335,"correct":26},"测试过程中系统排出的水应通过排水设施全部排走，湿式报警阀处的排水立管不宜小于DN75",{"key":24,"text":337,"correct":22},"开启末端试水装置，以1.2L\u002FS的流量放水，水流指示器、湿式报警阀、压力开关应动作",{"key":28,"text":339,"correct":22},"消防联动控制器应准确接收并显示水流指示器、压力开关、水泵的反馈信号",{"key":31,"text":341,"correct":22},"压力开关应直接连锁启动消防水泵",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":28,"analysis":33},935000,"(2016年真题)某建筑自动喷水灭火系统采用玻璃球洒水喷头，其中部分喷头玻璃球色标为黄色。该喷头公称动作温度为（??）℃",[346,348,350,352],{"key":20,"text":347,"correct":22},"57",{"key":24,"text":349,"correct":22},"68",{"key":28,"text":351,"correct":26},"79",{"key":31,"text":353,"correct":22},"93",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":28,"analysis":33},935001,"(2016年真题)检查自动喷水灭火系统，湿式报警阀前压力为0.35Mpa，打开湿式报警阀组试水阀，以1.2L\u002FS的流量防火，不带延迟器的水力警铃最迟在（??）S内发出报警铃声。",[358,360,362,364],{"key":20,"text":359,"correct":22},"5",{"key":24,"text":361,"correct":22},"30",{"key":28,"text":363,"correct":26},"15",{"key":31,"text":365,"correct":22},"90",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":31,"analysis":33},935002,"(2016年真题)某工地按现行国家标准《通用阀门压力试验》GB\u002FT13927《自动喷水灭火系统 第6部分：通用阀门》GB5135.6的要求，对消防用碟阀开展进行检验。下列检查项目中，不属于进场检查的项目是（??）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"外观质量检查",{"key":24,"text":373,"correct":22},"规格型号检查",{"key":28,"text":375,"correct":22},"开关指示标志",{"key":31,"text":377,"correct":26},"水头损失检查",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},935003,"(2016年真题) 为了防止建筑物在火灾时发生轰然，有效的方法是采用自动喷水灭火系统保护建筑物，闭式自动喷水灭火系统必须在（??）启动并控制火灾的增长",[382,384,386,388],{"key":20,"text":383,"correct":22},"火灾自动报警系统的感烟探测器探测到火灾之前",{"key":24,"text":385,"correct":22},"火灾自动报警系统的感温探测器探测到火灾之前",{"key":28,"text":387,"correct":22},"火灾自动报警系统接收到手动报警按钮信号之前",{"key":31,"text":389,"correct":26},"起火房间达到轰然阶段之前",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},935004,"(2015年真题) 闭式自动喷水灭火系统施工安装前，需对已进场的闭式喷头进行密封性能试验。下列情况中，符合相关施工验收规范要求的是（）。",[394,396,398,400],{"key":20,"text":395,"correct":26},"施工单位按规范要求抽样并使用专用试验装置进行密封性能试验",{"key":24,"text":397,"correct":22},"密封性能试验压力为3MPa，保压时间1min",{"key":28,"text":399,"correct":22},"施工单位按每批喷头总数量的1%抽样送国家法定检测机构进行密封性能试验",{"key":31,"text":401,"correct":22},"施工单位按每批喷头5只喷头抽样送国家法定检测机构进行密封性能试验",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":31,"analysis":33},935005,"(2015年真题) 下列关于自动喷水灭火系统水力警铃故障原因的说法中，错误的是（）。",[406,408,410,412],{"key":20,"text":407,"correct":22},"未按照水力警铃的图样进行组件的安装",{"key":24,"text":409,"correct":22},"水力警铃产品质量不合格或损坏",{"key":28,"text":411,"correct":22},"水力警铃的喷嘴堵塞或叶轮、铃锤组件卡阻",{"key":31,"text":413,"correct":26},"水力警铃前的延迟器下部孔板的溢出水孔堵塞",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":28,"analysis":33},935006,"(2015年真题) 对自动喷水灭火系统实施检查维护，下列项目中，属于年度检查内容的是（）。",[418,420,422,424],{"key":20,"text":419,"correct":22},"报警阀组启动性能测试",{"key":24,"text":421,"correct":22},"水流指示器动作性能测试",{"key":28,"text":423,"correct":26},"水源供水能力测试",{"key":31,"text":425,"correct":22},"水泵接合器完好性检查",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":24,"analysis":33},935007,"(2015年真题) 对自动灭火系统洒水喷头进行现场检查时，应确认其标志齐全。直立型玻璃球喷头溅水盘或者本体上至少应具有商标、型号、公称动作温度、制造厂（代号）、生产日期及（）等标志。",[430,432,434,436],{"key":20,"text":431,"correct":22},"玻璃球色标",{"key":24,"text":433,"correct":26},"响应时间指数",{"key":28,"text":435,"correct":22},"玻璃球公称直径",{"key":31,"text":437,"correct":22},"水流方向",{"id":439,"libraryId":5,"type":36,"typeLabel":37,"stem":440,"options":441,"answer":452,"analysis":33},935008,"（2020年真题）某消防技术服务机构对某大学综合楼设置的湿式自动喷水灭火系统进行维护保养。根据现行国家标准《自动喷水灭火系统施工及验收规范》（GB50261），下列消防设施维护保养的做法中，符合规范要求的有（ ）。",[442,444,446,448,450],{"key":20,"text":443,"correct":22},"每月用手动、自动方式分别启动一次消防水泵，完成后将水泵控制位设置在手动挡",{"key":24,"text":445,"correct":26},"每天手动切换消防水泵房内双电源互投柜的主、备电源，完成后恢复到主电源供电",{"key":28,"text":447,"correct":26},"每季度打开报警阀组的放水阀，检查系统启动、报警功能，完成后关闭放水阀",{"key":31,"text":449,"correct":26},"每月打开消防水箱玻璃水位计两端的角阀，观察水箱水位情况，完成后关闭角阀",{"key":49,"text":451,"correct":22},"每季度打开末端试水装置的试水法检查水流指示器的动作情况，完成后关闭试水阀","BCD",{"id":454,"libraryId":5,"type":36,"typeLabel":37,"stem":455,"options":456,"answer":153,"analysis":33},935009,"（2020年真题）某医院综合楼地上各层设置湿式自动喷水灭火系统，地下1层设置预作用自动喷水灭火系统。对该自动喷水灭火系统检测的下列结果中，符合现行国家标准《自动喷水灭火系统施工及验收规范》的有（ ）。",[457,459,461,463,465],{"key":20,"text":458,"correct":22},"打开第2层的末端试水装置，在距离水力警铃0.3米远处测得的声强为65dB",{"key":24,"text":460,"correct":26},"打开第4层的末端试水装置后，120秒消防水泵自动启动",{"key":28,"text":462,"correct":22},"使地下1层的一只感烟火灾探测器，发出报警信号预作用报警阀组启动",{"key":31,"text":464,"correct":26},"手动开启预作用阀组后90s，预作用系统处于开启状态的末端试水装置出水",{"key":49,"text":466,"correct":26},"打开消防水泵出水管上的试水阀，手动启泵后切换备用电源，消防水泵在50s时开启",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":31,"analysis":33},935010,"（2020年真题）某消防技术服务机构对某医院设置的自动喷水灭火系统进行了防火检查，检查结果中符合现行国家标准《自动喷水灭火系统施工及验收规范》的是（ ）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"车库中安装的个别直立型喷头，感温元件被喷涂白色涂料",{"key":24,"text":474,"correct":22},"报警阀组前的闸阀处于关闭状态，且锁链完好",{"key":28,"text":476,"correct":22},"对消防水箱的水位属于满水位置，但玻璃液液位计无水位显示",{"key":31,"text":478,"correct":26},"消防水泵控制柜设置在单独的房间内，控制柜处于自动控制状态",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":28,"analysis":33},935011,"（2020年真题）某单位对进场的湿式报瞽阀组进行渗漏检验，下列试验方法及结果中符合现行国家标准《自动喷水灭火系统施工及验收规范》（GB 50261）的是（ ）。",[483,485,487,489],{"key":20,"text":484,"correct":22},"试验压力为报警阀额定工作压力的1.0倍，保压20min，阀瓣处无渗漏",{"key":24,"text":486,"correct":22},"试验压力为报警阀额定工作压力的1.2倍，保压15min，阀瓣处无渗漏",{"key":28,"text":488,"correct":26},"试验压力为报警阀额定工作压力的2.0倍，保压5min，阀瓣处无渗漏",{"key":31,"text":490,"correct":22},"试验压力为报警阀额定工作压力的1.5倍，保压10min，阀瓣处无渗漏",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":24,"analysis":33},935012,"（2020年真题）某剧院舞台葡萄架处设置了由火灾自动报警系统启动的雨淋自动喷水灭火系统，下列系统组件中，属于该雨淋系统的是（ ）.",[495,497,499,501],{"key":20,"text":496,"correct":22},"湿式报警阀组",{"key":24,"text":498,"correct":26},"水流报警装置",{"key":28,"text":500,"correct":22},"快速响应喷头",{"key":31,"text":502,"correct":22},"未端试水装置",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":33},935013,"（2020年真题）对某酒店内的自动喷水灭火系统检测的下列结果，不符合《自动喷水灭火系统施工及验收规》（G8 50261）的是（ ）.",[507,509,511,513],{"key":20,"text":508,"correct":22},"酒店客房内设置的隐蔽式洒水喷头间距为2.2m，距墙1.2m",{"key":24,"text":510,"correct":26},"地下车库中—配水支管上安装了10只直立型洒水喷头",{"key":28,"text":512,"correct":22},"设在酒店顶层的末端试水装置的压力表读数为0.16MPa",{"key":31,"text":514,"correct":22},"开启末端试水装置，以1.1L\u002Fs，的流量放水50s时，消防水泵启动",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":20,"analysis":33},935014,"（2020年真题）对某办公楼的自动喷水灭火系统的水流指示器进行功能检查时，在第五层末端试水装置处以1.5L\u002Fs的流量放水，消防控制室未收到该层水流指示器的动作反馈信号。下列关于未收到动作反馈信号的原因分析中，可以排除的是（ ）。",[519,521,523,525],{"key":20,"text":520,"correct":26},"水流指示器前的信号蝶阀未完全打开",{"key":24,"text":522,"correct":22},"与水流指示器链接的监视模块故障",{"key":28,"text":524,"correct":22},"水流指示器的信号反馈线路接线不实",{"key":31,"text":526,"correct":22},"水流指示器的叶片被异物、杂质等卡阻",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":28,"analysis":33},935015,"（2020年真题）某地下停车场无吊顶。设有预作用自动喷水灭火系统，某消防技术服务机构，对该系统中的喷头安装质量进行检查，下列检查结果中不符合现行国家标准《自动喷水灭火系统施工及验收规范》的是（ ）。",[531,533,535,537],{"key":20,"text":532,"correct":22},"直立型标准覆盖面，洒水喷头溅水盘与顶板的距离为100mm",{"key":24,"text":534,"correct":22},"同—配水支管上安装的洒水喷头的间距为3.0m",{"key":28,"text":536,"correct":26},"通风管道覆面下安装的喷头类型为下垂型标准覆盖面洒水喷头",{"key":31,"text":538,"correct":22},"喷水距梁的水平距离为1.2米，喷头溅水盘距梁底的垂直距离为250mm",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":20,"analysis":33},935016,"（2020年真题）根据现行国家标准《自动喷水灭火系统施工及验收规范》（GB 50261），下列实验内容中不属于湿式自动喷水灭火系统调试内容的是（ ）。",[543,545,547,549],{"key":20,"text":544,"correct":26},"对系统管网进行严密性试验，测试系统管网的密封性能",{"key":24,"text":546,"correct":22},"从湿式报警阀组的试水装置处放水，测试报警阀组的报警功能",{"key":28,"text":548,"correct":22},"以手动和自动方式启动消防水泵，测试消防水泵投入正常运行的时间",{"key":31,"text":550,"correct":22},"通过移动式消防水泵向水泵结合器供水，测试消防水泵结合器的供水能力",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":24,"analysis":33},935017,"（2019年真题）某高层酒店，地下燃油，燃气锅炉房内设置水喷雾灭火系统。分解现行国家标准《水喷雾灭火系统技术规范》(GB50219)，对该系统进行检查验收，下列检测结果中，不符合规范要求的是（）。",[555,557,559,561],{"key":20,"text":556,"correct":22},"水雾喷头布置在锅炉的顶部周围，水雾直接喷向锅炉",{"key":24,"text":558,"correct":26},"雨淋报警阀前的管道过滤网为316L不锈钢，其网孔为0.50mm",{"key":28,"text":560,"correct":22},"雨淋报警阀后的管道采用铜管",{"key":31,"text":562,"correct":22},"主、备供水泵均采用柴油泵",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":31,"analysis":33},935018,"（2019年真题）某髙层建筑内的柴油发电机房设置了水喷雾灭火系统,水雾喷火的有效喷射程为2.5m,雾化角为90°,喷头与被保护对象的距离为1.0m,某消防技术服务机构对该系统进行检测,根据现行国家标的准《水喷雾灭火系统技术规范》(GB50219),下列检测结果中,符合规范要求的是（）",[567,569,571,573],{"key":20,"text":568,"correct":22},"水雾喷头的平面布置方式为矩形,喷头间距为1.5m",{"key":24,"text":570,"correct":22},"顶部喷头的安装坐标偏差值为50mm",{"key":28,"text":572,"correct":22},"侧向喷头与被保护对象的安装距离偏差值为100m",{"key":31,"text":574,"correct":26},"管道支架与水雾喷头之间的距离为0.4m",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":24,"analysis":33},935019,"(2018年真题) 根据现行国家标准《水喷雾灭火系统技术规范》(GB50219)，关于水喷雾灭火系统管道水压试验的说法，正确的是( )。",[579,581,583,585],{"key":20,"text":580,"correct":22},"水压试验时应采取防冻措施的最高环境温度为4℃",{"key":24,"text":582,"correct":26},"不能参与试压的设备，应加以隔离或拆除",{"key":28,"text":584,"correct":22},"试验的测试点宜设在系统管网的最高点",{"key":31,"text":586,"correct":22},"水压试验的试验压力应为设计压力的1.2倍",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":24,"analysis":33},935020,"(2017年真题)某消防工程施工单位分别以自动、手动方式对处于自动控制状态下的水喷雾灭火系统进行联动试验 。 下列试验次数最少且符合现行国家标准要求的是（??）。",[591,593,595,597],{"key":20,"text":592,"correct":22},"自动3次、 手动2次",{"key":24,"text":594,"correct":26},"自动2次、 手动2次",{"key":28,"text":596,"correct":22},"自动2次、 手动3次",{"key":31,"text":598,"correct":22},"自动3次、 手动3次",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":28,"analysis":33},935021,"(2018年真题)酒店设置有水喷雾灭火系统，检查中发现雨淋报警阀组自动滴水阀漏水。下列原因分析中，与该漏水现象无关的是()",[603,605,607,609],{"key":20,"text":604,"correct":22},"系统侧管道中余水未排净",{"key":24,"text":606,"correct":22},"雨淋报警阀密封橡胶件老化",{"key":28,"text":608,"correct":26},"雨淋报警阀组快速复位阀关闭",{"key":31,"text":610,"correct":22},"雨淋报警阀阀瓣密封处有杂物",{"id":612,"libraryId":5,"type":15,"typeLabel":16,"stem":613,"options":614,"answer":24,"analysis":33},935022,"(2018年真题)水喷雾灭火系统投入运行后应进行维护管理，根据现行国家标准 《水喷雾灭火系统技术规范》(GB50219)，维护管理人员应掌握的知识与技能不包括 ( )。",[615,617,619,621],{"key":20,"text":616,"correct":22},"熟悉水喷雾灭火系统的操作维护规程",{"key":24,"text":618,"correct":26},"熟悉水喷雾灭火系统各组件的结构",{"key":28,"text":620,"correct":22},"熟悉水喷雾灭火系统的性能",{"key":31,"text":622,"correct":22},"熟悉水喷雾灭火系统的原理",{"id":624,"libraryId":5,"type":15,"typeLabel":16,"stem":625,"options":626,"answer":28,"analysis":33},935023,"(2016年真题)根据《水喷雾灭火系统技术规范》GB50219,对水喷雾灭火系统应进行联动试验检查，系统响应时间，工作压力和流量应符合设计要求：当系统为手动控制时，应以手动方式进行至少（??）试验，检查系统的动作情况及信号反馈情况。",[627,629,631,633],{"key":20,"text":628,"correct":22},"3次",{"key":24,"text":630,"correct":22},"4次",{"key":28,"text":632,"correct":26},"1次",{"key":31,"text":634,"correct":22},"5次",{"id":636,"libraryId":5,"type":15,"typeLabel":16,"stem":637,"options":638,"answer":24,"analysis":33},935024,"（2020年真题）对某油浸式电力变压器室设置的水喷雾灭火系统检测的下列结果中,不符合现行国家标准《水喷雾灭火系统技术规范》（GB50219）的是（ ）。",[639,641,643,645],{"key":20,"text":640,"correct":22},"管道支架与末端喷头之间的距离为0.4m",{"key":24,"text":642,"correct":26},"系统喷头采用撞击型水雾喷头",{"key":28,"text":644,"correct":22},"压力开关的引出线用金属防水套管锁定",{"key":31,"text":646,"correct":22},"打开雨淋阀手动开启装置后10s,雨淋报警阀启动",[648,651,654,657,660,663],{"id":15,"name":649,"category":7,"favorite":650},"领导干部任职前廉政法规知识测试题",92,{"id":652,"name":653,"category":7,"favorite":15},595,"建筑结构与设备",{"id":655,"name":656,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":658,"name":659,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":661,"name":662,"category":7,"favorite":8},534,"BIM工程师",{"id":664,"name":662,"category":7,"favorite":8},535]