[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-60":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":309},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,60,50,2974,[13,34,46,58,70,82,94,105,117,129,141,153,165,177,189,201,213,225,237,249,261,273,285,297],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},937647,1,"单选题","自动喷水灭火系统试压、冲洗合格后，要进行喷头安装；安装前，查阅消防设计文件，确定不同使用场所的喷头型号、规格。其中梁、通风管道、排管、桥架宽度大于（ ）m时，在其腹面以下部位增设喷头。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1.1",false,{"key":24,"text":25,"correct":26},"B","1.2",true,{"key":28,"text":29,"correct":22},"C","1.3",{"key":31,"text":32,"correct":22},"D","1.4","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},937648,"自动喷水灭火系统试压、冲洗合格后，要进行喷头安装；安装前，查阅消防设计文件，确定不同使用场所的喷头型号、规格。下列对喷头的安装不符合要求的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"采用专用安装喷头，严禁利用喷头的框架施拧",{"key":24,"text":41,"correct":22},"喷头的框架、溅水盘产生变形、释放原件损伤的，采用规格、型号相同的喷头进行更换",{"key":28,"text":43,"correct":26},"喷头安装时，为美观要求可以对喷头进行拆装、改动",{"key":31,"text":45,"correct":22},"当喷头的公称直径小于10mm时，在系统配水干管、配水管上安装过滤器",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},937649,"自动喷水灭火系统报警阀组垂直安装在配水干管上，水源控制阀、报警阀组水流标识与系统水流方向一致。报警阀组的安装顺序为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"水源控制阀→报警阀→报警阀辅助管道",{"key":24,"text":53,"correct":22},"水源控制阀→报警阀辅助管道→报警阀",{"key":28,"text":55,"correct":22},"报警阀→水源控制阀→报警阀辅助管道",{"key":31,"text":57,"correct":22},"报警阀→报警阀辅助管道→水源控制阀",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},937650,"干式报警阀组安装及质量检测要求中充气连接管路的接口安装在报警阀气室充注水位以上部位，充气连接管道的直径不得小于（ ）mm；止回阀、截止阀安装在充气连接管路上。",[62,64,66,68],{"key":20,"text":63,"correct":26},"15",{"key":24,"text":65,"correct":22},"25",{"key":28,"text":67,"correct":22},"35",{"key":31,"text":69,"correct":22},"45",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},937651,"使用信号阀和水流指示器控制的自动喷水灭火系统，信号阀安装在水流指示器前的管道上，与水流指示器间的距离不小于（ ）mm。",[74,76,78,80],{"key":20,"text":75,"correct":22},"100",{"key":24,"text":77,"correct":22},"200",{"key":28,"text":79,"correct":26},"300",{"key":31,"text":81,"correct":22},"400",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},937652,"自动喷水灭火系统管网气压严密性试验压力为0.28MPa，且稳压24h，压力降不大于（ ）MPa。",[86,88,90,92],{"key":20,"text":87,"correct":26},"0.01",{"key":24,"text":89,"correct":22},"0.02",{"key":28,"text":91,"correct":22},"0.03",{"key":31,"text":93,"correct":22},"0.04",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},937653,"雨淋报警阀组调试采用检测、试验管道进行供水。自动和手动方式启动的雨淋报警阀，在联动信号发出或者手动控制操作后15s内启动；公称直径大于200mm的雨淋报警阀，在60s之内启动。雨淋报警阀调试时，当报警水压为（ ）MPa，水力警铃发出报警铃声。",[98,99,101,103],{"key":20,"text":91,"correct":22},{"key":24,"text":100,"correct":26},"0.05",{"key":28,"text":102,"correct":22},"0.07",{"key":31,"text":104,"correct":22},"0.09",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},937654,"自动喷水灭火系统联动调试及检测中，湿式系统、干式系统和预作用系统等系统控制装置设置为（ ）控制方式，启用喷头或模拟火灾自动报警系统输入火灾探测信号等进行联动调试。",[109,111,113,115],{"key":20,"text":110,"correct":22},"手动",{"key":24,"text":112,"correct":26},"自动",{"key":28,"text":114,"correct":22},"紧急启动／停止",{"key":31,"text":116,"correct":22},"机械应急启动",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":20,"analysis":33},937655,"自动喷水灭火系统验收检查中需查验喷头备用量，国家工程消防技术标准规定各种不同规格的喷头的备用品数量不少于安装喷头总数的1%，且每种备用喷头不少于（ ）个。",[121,123,125,127],{"key":20,"text":122,"correct":26},"10",{"key":24,"text":124,"correct":22},"20",{"key":28,"text":126,"correct":22},"30",{"key":31,"text":128,"correct":22},"40",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":28,"analysis":33},937656,"报警阀组验收检查的合格判定标准中，要求水力警铃3m远处警铃声声强符合设计文件要求，且不小于（ ）dB。",[133,135,137,139],{"key":20,"text":134,"correct":22},"50",{"key":24,"text":136,"correct":22},"60",{"key":28,"text":138,"correct":26},"70",{"key":31,"text":140,"correct":22},"80",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":31,"analysis":33},937657,"下列关于喷头安装前的检查内容，说法不正确的是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"喷头装配性能检查要求：旋拧喷头顶丝，不得轻易旋开，转动溅水盘，无松动、变形等现象，以确保喷头不被轻易调整、拆卸和重装",{"key":24,"text":148,"correct":22},"边墙型喷头上有水流方向标识，隐蔽式喷头的盖板上有“不可涂覆”等文字标识",{"key":28,"text":150,"correct":22},"所有标识均为永久性标识，标识正确、清晰",{"key":31,"text":152,"correct":26},"使用天平测量每只喷头的质量，偏差不得超过10%",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":24,"analysis":33},937658,"下列关于闭式喷头密封性能试验的说法中，不正确的是（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"密封性能试验的试验压力为3.0MPa，保压时间不少于3min",{"key":24,"text":160,"correct":26},"随机从每批到场喷头中抽取1%，且不少于10只作为试验喷头",{"key":28,"text":162,"correct":22},"当一只喷头试验不合格时，再抽取2%，且不少于10只的到场喷头进行重复试验",{"key":31,"text":164,"correct":22},"试验以喷头无渗漏、无损伤判定为合格。累计两只以及两只及以上喷头试验不合格的，不得使用该批喷头",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":31,"analysis":33},937659,"下列关于干式报警阀组的安装及质量检测要求，说法正确的是（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":22},"安装完成后，向报警阀气室注入高度为100~150mm的清水",{"key":24,"text":172,"correct":22},"充气连接管道的直径不得小于20mm，并应安装止回阀、截止阀",{"key":28,"text":174,"correct":22},"安全排气阀安装在空压机上，超压时及时排气，保证系统安全",{"key":31,"text":176,"correct":26},"加速器安装在靠近报警阀的位置，加速器能加速开启报警阀，排气充水灭火",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":20,"analysis":33},937660,"对报警阀组进行年度检测时各类报警阀组（装置）要求中不正确的是。",[181,183,185,187],{"key":20,"text":182,"correct":26},"湿式报警阀组检查时，开启末端试水装置必须在3min内，消防水泵自动启动",{"key":24,"text":184,"correct":22},"干式报警阀组检查时，开启末端试水装置出水1min后，出水压力≥0.05MPa",{"key":28,"text":186,"correct":22},"预作用报警装置检查时，开启末端试水装置，火灾报警控制器确认火灾2min后，其出水压力≥0.05MPa",{"key":31,"text":188,"correct":22},"检查消防控制设备准确显示电磁阀、电动阀、水流指示器以及消防水泵动作信号，反馈信号准确",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":20,"analysis":33},937661,"水流指示器的现场功能检查：检查水流指示器灵敏度，试验压力为0.14~1.2MPa，流量在（ ）任一数值上报警，且到达（ ）一定报警。",[193,195,197,199],{"key":20,"text":194,"correct":26},"15.0~37.5L\u002Fmin，37.5L\u002Fmin",{"key":24,"text":196,"correct":22},"15.0~35L\u002Fmin，1L\u002Fs",{"key":28,"text":198,"correct":22},"5.0~37.5L\u002Fmin，1L\u002Fs",{"key":31,"text":200,"correct":22},"15.0~35L\u002Fmin，37.5L\u002Fmin",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":24,"analysis":33},937662,"对水流指示器进行周期性检查、测试：利用（ ）对水流指示器进场动作、报警检查试验时，首先检查（ ）的完好性，符合试验条件的，开启（ ），发现水流指示器在规定时间内不报警的，首先检查（ ），存在断路、接线不实等情况的，重新接线至正常。之后，检查水流指示器，发现有异物、杂质等卡阻桨片的，及时清除异物、杂质；发现调整螺母与触头未到位的，重新调试到位。Ⅰ、末端试水装置、楼层试水阀；Ⅱ、消防联动控制设备和末端试水装置、楼层试水阀；Ⅲ、末端试水装置或者试水阀；Ⅳ、水流指示器的控制线路；Ⅴ、水流指示器与管道的连接；",[205,207,209,211],{"key":20,"text":206,"correct":22},"Ⅰ、Ⅰ、Ⅲ、Ⅳ",{"key":24,"text":208,"correct":26},"Ⅰ、Ⅱ、Ⅲ、Ⅳ",{"key":28,"text":210,"correct":22},"Ⅰ、Ⅰ、Ⅲ、Ⅴ",{"key":31,"text":212,"correct":22},"Ⅰ、Ⅱ、Ⅲ、Ⅴ",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":28,"analysis":33},937663,"自动喷水灭火系统年度检测，关于末端试水装置检测操作步骤说法错误的是（ ）。",[217,219,221,223],{"key":20,"text":218,"correct":22},"现场查看末端试水装置的阀门、压力表、试水接头及排水管等外观",{"key":24,"text":220,"correct":22},"关闭末端试水装置，读取并记录其压力表数值；开启末端试水装置的控制阀，待压力表指针晃动平稳后，读取并记录压力表数值",{"key":28,"text":222,"correct":26},"水泵自动启动3min后，读取并记录压力表数值，观察其变化情况",{"key":31,"text":224,"correct":22},"关闭末端试水装置，系统复位，恢复到工作状态",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},937664,"某焦化企业磨煤车间按相关要求设有自动喷水灭火系统，一级消防工程师王某定期检查维护时发现湿式报警阀组漏水。下列不属于湿式报警阀组漏水的原因的是（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":26},"限流装置过滤网被堵塞",{"key":24,"text":232,"correct":22},"阀瓣密封垫老化或者损坏",{"key":28,"text":234,"correct":22},"排水阀门未完全关闭",{"key":31,"text":236,"correct":22},"报警管路测试控制阀渗漏",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":24,"analysis":33},937665,"某市政府办公室设有自动喷水灭火系统，消防员上次周期性检查维护时间为2015年12月，则2016年3月（季度检查）应检查维护的项目是（ ）。",[241,243,245,247],{"key":20,"text":242,"correct":22},"喷头完好情况",{"key":24,"text":244,"correct":26},"报警阀组的试水阀放水及其启动性能测试",{"key":28,"text":246,"correct":22},"电磁阀启动测试",{"key":31,"text":248,"correct":22},"水泵接合器通水加压测试",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":31,"analysis":33},937666,"下列关于自动喷水灭火系统湿式和干式二种报警阀功能的叙述中，错误的是（ ）。",[253,255,257,259],{"key":20,"text":254,"correct":22},"均具有喷头动作后报警水流驱动水力警铃和压力开关报警的功能",{"key":24,"text":256,"correct":22},"均具有防止系统水流倒流至水源的止回功能",{"key":28,"text":258,"correct":22},"均具有接通或关断报警水流的功能",{"key":31,"text":260,"correct":26},"均具有延迟误报警的功能",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":31,"analysis":33},937667,"雨淋报警阀启动装置中电动系统的组成不包括（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":22},"火灾探测器",{"key":24,"text":268,"correct":22},"电磁阀",{"key":28,"text":270,"correct":22},"联动控制系统",{"key":31,"text":272,"correct":26},"闭式喷头",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":24,"analysis":33},937668,"下列关于自动喷水灭火系统喷头现场检验的说法，不正确的是（ ）。",[277,279,281,283],{"key":20,"text":278,"correct":22},"喷头螺纹封面应无缺丝、断丝现象",{"key":24,"text":280,"correct":26},"闭式喷头应进行密封性能试验，当不合格喷头数不大于2只时，该批喷头可以使用",{"key":28,"text":282,"correct":22},"喷头的商标、型号、公称动作温度、响应时间指数、制造厂及生产日期等标志应齐全",{"key":31,"text":284,"correct":22},"闭式喷头应进行密封性能试验，当仅有一只不合格时，应再抽查2%，并不得少于10只",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":31,"analysis":33},937669,"某民用建筑内的自动喷水灭火系统采用型号为“ZSTG”的喷头，则该喷头为（ ）。",[289,291,293,295],{"key":20,"text":290,"correct":22},"直立型喷头",{"key":24,"text":292,"correct":22},"下垂型喷头",{"key":28,"text":294,"correct":22},"齐平式喷头",{"key":31,"text":296,"correct":26},"干式喷头",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":24,"analysis":33},937670,"对自动喷水灭火系统的喷头进行检查时，应对其质量偏差进行检查，下列关于喷头质量偏差检查的说法，不正确的是（ ）。",[301,303,305,307],{"key":20,"text":302,"correct":22},"随机抽取1%且不少于5只的喷头进行检查（带有运输护帽的摘下护帽）",{"key":24,"text":304,"correct":26},"随机抽取3只喷头进行检查（带有运输护帽的摘下护帽）",{"key":28,"text":306,"correct":22},"随机抽取1%且不少于10只的喷头进行检查（带有运输护帽的摘下护帽）",{"key":31,"text":308,"correct":22},"随机抽取5只喷头进行检查（带有运输护帽的摘下护帽）",[310,313,316,319,322,325],{"id":15,"name":311,"category":7,"favorite":312},"领导干部任职前廉政法规知识测试题",92,{"id":314,"name":315,"category":7,"favorite":15},595,"建筑结构与设备",{"id":317,"name":318,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":320,"name":321,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":323,"name":324,"category":7,"favorite":8},534,"BIM工程师",{"id":326,"name":324,"category":7,"favorite":8},535]