[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":635},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,6,50,2974,[13,34,46,64,76,88,100,112,124,136,148,156,168,180,192,202,214,226,238,250,262,277,289,301,313,325,337,345,357,369,381,393,408,420,432,444,456,471,485,497,509,521,533,545,557,569,584,599,611,623],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},934925,1,"单选题","(2016年真题) 对建筑进行火灾风险评估之后，需要采取一定的风险控制措施，下列措施中，不属于风险控制措施的是（??）",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","风险消除",false,{"key":24,"text":25,"correct":22},"B","风险减少",{"key":27,"text":28,"correct":29},"C","风险分析",true,{"key":31,"text":32,"correct":22},"D","风险转移","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},934926,"(2016年真题) 某住宅小区采用临时高压消防给水系统，电动消防水泵供水，高位消防水箱稳压，运行维护管理时，根据现行国家消防技术标准，正确的做法是（??）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"每季度检查供电情况",{"key":24,"text":41,"correct":22},"每年测试泵的流量和压力",{"key":27,"text":43,"correct":22},"每周对稳压泵的停泵启泵压力进行检查",{"key":31,"text":45,"correct":29},"每月手动启动消防泵运行，并检查供电情况",{"id":47,"libraryId":5,"type":48,"typeLabel":49,"stem":50,"options":51,"answer":63,"analysis":33},934927,2,"多选题","(2016年真题) 下列关于消防水泵接合器的安装要求的说法中，正确的有（??）",[52,54,56,58,60],{"key":20,"text":53,"correct":29},"应安装在便于消防车接近使用的地点",{"key":24,"text":55,"correct":29},"墙壁式消防水泵接合器不应安装在玻璃墙下方",{"key":27,"text":57,"correct":29},"墙壁式消防水泵接合器与门窗洞口的净距不应小于2.0m",{"key":31,"text":59,"correct":22},"距室外消火栓或消防水池的距离以为5m-40m",{"key":61,"text":62,"correct":22},"E","地下消防水泵接合器进水口与井盖底部的距离不应小于井盖的直径","ABC",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":31,"analysis":33},934928,"(2017年真题)某在建工程，单体体积为35000m3，设计建筑高度为23.5m，临时用房建筑面积为1200㎡，设置了临时室内、外消防给水系统。该建筑工程施工现场临时消防设施设置的做法中，不符合现行国家消防技术标准要求的是(??)",[68,70,72,74],{"key":20,"text":69,"correct":22},"临时室外消防给水干管的管径采用DN100",{"key":24,"text":71,"correct":22},"设置了两根室内临时消防竖管",{"key":27,"text":73,"correct":22},"每个室内消火栓处只设置接口，未设置消防水带和消防水枪",{"key":31,"text":75,"correct":29},"在建工程临时室外消防用水量按火灾延续时间1.00h确定",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":24,"analysis":33},934929,"(2017年真题)下列设备和设施中，属于临时高压消防给水系统构成必需的设备设施是（??）",[80,82,84,86],{"key":20,"text":81,"correct":22},"消防稳压泵",{"key":24,"text":83,"correct":29},"消防水泵",{"key":27,"text":85,"correct":22},"消防水池",{"key":31,"text":87,"correct":22},"市政管网",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":27,"analysis":33},934930,"(2017年真题)按照施工过程质量控制要求，消防给水系统安装前应对采用的主要设备、系统组件、管材管件及其他设备、材料进行现场检验。根据现行国家标准《消防给水及消火栓系统技术规范》GB50974，下列说法中，正确的是（??）",[92,94,96,98],{"key":20,"text":93,"correct":22},"流量开关应经相应国家产品质量监督检验中心检验合格",{"key":24,"text":95,"correct":22},"消防水箱应经国家消防产品质量监督检验中心检验合格",{"key":27,"text":97,"correct":29},"压力开关应经国家消防产品质量监督检验中心检验合格",{"key":31,"text":99,"correct":22},"安全阀应经国家消防产品质量监督检验中心检验合格",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":31,"analysis":33},934931,"(2018年真题)某旅馆，地下 1 层，地上 4 层，每层高 4m，设置常高压消防给水系统，高位消防水池设于 100m 外的山坡上，与建筑屋面高差60m，根据现行国家标准《消防给水及消火栓系统技术规范》(GB50974)，该旅馆消防给水系统的调试方案可不包含的内容是（??）",[104,106,108,110],{"key":20,"text":105,"correct":22},"水源测试",{"key":24,"text":107,"correct":22},"消火栓调试",{"key":27,"text":109,"correct":22},"给水设施调试",{"key":31,"text":111,"correct":29},"消防水泵调试",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":24,"analysis":33},934932,"(2018年真题)某消防工程施工单位对已安装的消防水泵进行调试，水泵的额定流量为 30L\u002Fs，扬程为 100m，系统设计工作压力为 1.0MPa。下列调试结果中，符合现行国家标准《消防给水及消火栓系统技术规范》(GB 50974)的是（ ）",[116,118,120,122],{"key":20,"text":117,"correct":22},"自动直接启动消防水泵时，消防水泵在 60s 时投入正常运行",{"key":24,"text":119,"correct":29},"消防水泵零流量时，水泵出水口压力表的显示压力为 1.30MPa",{"key":27,"text":121,"correct":22},"以备用电源的切换方式启动消防水泵时，消防水泵在 2min 时投入正常运行",{"key":31,"text":123,"correct":22},"消防水泵出口流量为 45L\u002Fs 时，出口处压力表显示未为0.55MPa",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":20,"analysis":33},934933,"(2015年真题) 下列有关消防水泵接合器安装说法中，错误的是（）。",[128,130,132,134],{"key":20,"text":129,"correct":29},"墙壁水泵接合器安装高度距地面宜为1.1m",{"key":24,"text":131,"correct":22},"组装式消防水泵接合器的安装，应按接口、本体、连接管、止回阀、安全阀、放空管、控制阀的顺序进行",{"key":27,"text":133,"correct":22},"止回阀的安装方向应使消防用水能从消防水泵接合器进入系统",{"key":31,"text":135,"correct":22},"消防水泵接合器接口距离室外消火栓或消防水池的距离宜为15~40m",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":20,"analysis":33},934934,"(2016年真题) 某工地按现行国家标准《通用阀门压力试验》GB\u002FT13927和《自动喷水灭火系统第6部分：通用阀门》GB5135.6的要求，对消防用蝶阀进场检验，下列检查项目中，不属于进厂检验项目的是（）。",[140,142,144,146],{"key":20,"text":141,"correct":29},"水头损失检查",{"key":24,"text":143,"correct":22},"外观质量检查",{"key":27,"text":145,"correct":22},"规格型号检查",{"key":31,"text":147,"correct":22},"开关指示标志",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":20,"analysis":33},934935,"(2016年真题) .某住宅小区采用临时高压消防给水系统，电动消防水泵供水，高位消防水箱稳压，运行维护管理时，根据现行国家消防技术标准，正确的做法是（）。",[152,153,154,155],{"key":20,"text":45,"correct":29},{"key":24,"text":39,"correct":22},{"key":27,"text":41,"correct":22},{"key":31,"text":43,"correct":22},{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":24,"analysis":33},934936,"(2016年真题)对高位消防水箱进行维护保养，应定期检查水箱水位，检查水位的周期至少应为每（??）检查一次。",[160,162,164,166],{"key":20,"text":161,"correct":22},"日",{"key":24,"text":163,"correct":29},"月",{"key":27,"text":165,"correct":22},"季",{"key":31,"text":167,"correct":22},"年",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":24,"analysis":33},934937,"(2016年真题)消防给水系统维护管理人员，应掌握和熟悉消防给水系统的（??）、性能和操作规程。",[172,174,176,178],{"key":20,"text":173,"correct":22},"灭火机理",{"key":24,"text":175,"correct":29},"工作原理",{"key":27,"text":177,"correct":22},"运行规律",{"key":31,"text":179,"correct":22},"设计原理",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":24,"analysis":33},934938,"(2015年真题) 根据《消防给水及消火栓系统技术规范》（GB50974-2014）的规定，室内消火栓系统管网安装完成后，对其进行水压试验和冲洗的正确顺序是（）。",[184,186,188,190],{"key":20,"text":185,"correct":22},"强度试验--严密性试验--冲洗",{"key":24,"text":187,"correct":29},"强度试验--冲洗--严密性试验",{"key":27,"text":189,"correct":22},"冲洗--强度试验--严密性试验",{"key":31,"text":191,"correct":22},"冲洗--严密性试验--强度试验",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":20,"analysis":33},934939,"(2015年真题) 根据《消防给水及消火栓系统技术规范》（GB50974-2014）的规定，对消防给水系统供水设施进行维护管理，每（）应手动启动消防水泵运转一次，并应检查供电电源的情况。",[196,197,198,200],{"key":20,"text":163,"correct":29},{"key":24,"text":167,"correct":22},{"key":27,"text":199,"correct":22},"半年",{"key":31,"text":201,"correct":22},"季度",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":31,"analysis":33},934940,"（2020年真题）某消防技术服务机构对某高层建筑的室内消火栓系统进行了检测,消防后,屋顶试验用消火栓出水压力低于设计值。下列原因分析中,可以排除的是（ ）",[206,208,210,212],{"key":20,"text":207,"correct":22},"消防水泵出水管道阀门未完全开启",{"key":24,"text":209,"correct":22},"安装在消防水泵出口的超压泄水装置的动作压力设定值过低",{"key":27,"text":211,"correct":22},"管网内存在参与气体",{"key":31,"text":213,"correct":29},"消防水泵吸水管存在气囊",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},934941,"（2020年真题）对室内消防给水系统管网进行试压、冲洗的下列试验和操作方法,不符合现行国家标标准《消防给水及消火栓系统技术规范》（GB50971）的是（ ）",[218,220,222,224],{"key":20,"text":219,"correct":29},"严密性试验合格之后进行管网冲洗性试验",{"key":24,"text":221,"correct":22},"强度试验的介质采用清水",{"key":27,"text":223,"correct":22},"水压强度实验的测试点设在系统管网的最低处",{"key":31,"text":225,"correct":22},"管网采用分段方式进行冲洗",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},934942,"（2020年真题）给水系统给管材进场检验项目的是（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"核对管材的材质、型号、规格",{"key":24,"text":233,"correct":22},"检查管材的外观",{"key":27,"text":235,"correct":22},"检查管材的几何尺寸",{"key":31,"text":237,"correct":29},"对管材进行水压",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":24,"analysis":33},934943,"（2020年真题）对某高层办公建筑的消防给水系统进行维护保养的下列做法，不符合现行国家标准《消防给水及消火栓系统技术规范》（GB 50974）的是（ ）。",[242,244,246,248],{"key":20,"text":243,"correct":22},"每日检查一次消防水池、高位消防水箱的水位",{"key":24,"text":245,"correct":29},"每季度模拟自动控制条件自动启动消防水泵运转—次",{"key":27,"text":247,"correct":22},"每月手动启动消防水泵运转一次",{"key":31,"text":249,"correct":22},"每月检测一次气压水罐的压力和有效容积",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":31,"analysis":33},934944,"(2018年真题) 某消防工程施工单位对室内消火栓进行进场检验，根据现行国家标准《消防给水及消火栓系统技术规范》(GB50974)，下列关于消火栓固定接口密封性能试验抽样数量的说法，正确的是()",[254,256,258,260],{"key":20,"text":255,"correct":22},"宜从每批中抽查0.5%，但不应少于5个，当仅有1个不合格时，应再抽查1%但不应少于10个",{"key":24,"text":257,"correct":22},"宜从每批中抽查1%，但不应少于3个，当仅有1个不合格时，应再抽查2%但不应少于5个",{"key":27,"text":259,"correct":22},"宜从每批中抽查0.5%，但不应少于3个，当仅有1个不合格时，应再抽查1%但不应少于5个",{"key":31,"text":261,"correct":29},"宜从每批中抽查1%，但不应少于5个，当仅有1个不合格时，应再抽查2%但不应少于10个",{"id":263,"libraryId":5,"type":48,"typeLabel":49,"stem":264,"options":265,"answer":276,"analysis":33},934945,"(2016年真题)某住宅小区，有18栋20层住宅，建筑高度为57m，20层楼板标高为54.2m，高位消防水箱底标高为62.6m，室内消防采用联合供水的临时高压消防给水系统，设计流量57L\u002Fs．室外埋地供水干管采用DN200mm球墨铸铁管，长2000m，漏水率为1.40L／min.km，室内管网总的漏水量为0.25L\u002Fs，下列关于该系统稳压设施的设置和参数的设计的做法中，符合安全可靠、经济合理要求的有（??）",[266,268,270,272,274],{"key":20,"text":267,"correct":22},"临时高压消防给水系统采用高位消防水箱加稳压泵稳压的方式",{"key":24,"text":269,"correct":29},"高位消防水箱出水管的流量开关启动流量设计值为1.2L\u002Fs",{"key":27,"text":271,"correct":22},"高位消防水箱出水管的流量开关启动流量设计值为0.25L\u002Fs",{"key":31,"text":273,"correct":22},"高位消防水箱出水管的流量开关启动流量设计值为0.30L／s",{"key":61,"text":275,"correct":29},"临时高压消防绐水系统采用高位消防水箱稳压的方式","BE",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":33},934946,"(2017年真题)根据现行国家标准《消防给水及消火栓系统技术规范》GB50974，干式消火栓系统允许的最大充水时间是（ ）min",[281,283,285,287],{"key":20,"text":282,"correct":22},"10",{"key":24,"text":284,"correct":29},"5",{"key":27,"text":286,"correct":22},"2",{"key":31,"text":288,"correct":22},"3",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":24,"analysis":33},934947,"(2017年真题)某消防工程施工单位对消火栓系统进行施工前的进场检验，根据现行国家标准《消防给水及消火栓系统技术规范》GB50974，关于消火栓固定接口密封性能现场试验的说法中，正确的是（??）",[293,295,297,299],{"key":20,"text":294,"correct":22},"试验数量宜从每批中抽查1%，但不应少于3个",{"key":24,"text":296,"correct":29},"当仅有1个不合格时，应再抽查2%，但不应少于10个",{"key":27,"text":298,"correct":22},"应缓慢而均匀地升压至1.6MPa，并应保压1min",{"key":31,"text":300,"correct":22},"当第2次抽查仍有不合格时，应继续进行批量抽查，抽查数量按前次递增",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":31,"analysis":33},934948,"(2017年真题)某消防工程施工单位在消火栓系统安装结束后对系统进行调试。根据《消防给水及消火栓系统技术规范》(GB 50974)，关于消火栓调试和测试的说法中，正确的是（）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"只需测试一层消火栓的出流量、压力",{"key":24,"text":308,"correct":22},"应根据试验消火栓的流量，检测减压阀的减压能力",{"key":27,"text":310,"correct":22},"应在消防水泵启动后，检测消防水泵自动停泵的时间",{"key":31,"text":312,"correct":29},"应检查旋转型消火栓的性能",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":20,"analysis":33},934949,"(2018年真题)根据现行国家标准《消防给水及消火栓系统技术规范》(GB 50974)，室内消火栓系统上所有的控制阀门均应采用铅封锁链固定在开启或规定的状态，且应( )对铅封、锁链进行一次检查，当有破坏或损坏时应及时修理更换。",[317,319,321,323],{"key":20,"text":318,"correct":29},"每月",{"key":24,"text":320,"correct":22},"每季度",{"key":27,"text":322,"correct":22},"每半年",{"key":31,"text":324,"correct":22},"每年",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":27,"analysis":33},934950,"(2018年真题)某消防工程施工单位对系统设计工作压力为 0.8MPa 的消火栓系统进行严密性试验，下列做法中，正确的是（??）",[329,331,333,335],{"key":20,"text":330,"correct":22},"试验压力 0.96MPa，稳压 12h",{"key":24,"text":332,"correct":22},"试验压力 1.0MPa，稳压 10h",{"key":27,"text":334,"correct":29},"试验压力 0.8MPa，稳压 24h",{"key":31,"text":336,"correct":22},"试验压力 1.2MPa，稳压 8h",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":20,"analysis":33},934951,"(2017年真题) 根据国家标准《消防给水及消火栓系统技术规范》GB50974，对室内消火栓应()进行一次外观和漏水检查，发现存在问题的消火栓应及时修复或更换。",[341,342,343,344],{"key":20,"text":320,"correct":29},{"key":24,"text":318,"correct":22},{"key":27,"text":322,"correct":22},{"key":31,"text":324,"correct":22},{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":27,"analysis":33},934952,"(2016年真题)室内灭火栓的性能和质量应符合现行国家标准《室内消火栓》GB3445的要求。对室内消火栓进行施工现场检验时，下列检验项目中，不属于进场检验项目的是（??）",[349,351,353,355],{"key":20,"text":350,"correct":22},"油漆等外观质量检查",{"key":24,"text":352,"correct":22},"机械损伤检查",{"key":27,"text":354,"correct":29},"水压强度试验",{"key":31,"text":356,"correct":22},"密封性能试验",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":27,"analysis":33},934953,"(2016年真题)某超高层建筑，室内消火栓系统采用临时高压消防给水系统，并采用减压阀减压分区供水，减压阀设置在该区域最高部位。减压阀至最不利消火栓的水头损失为0.04Mpa，其阀后静，动压设计压力值分别为0.50Mpa，0.40Mpa。下列系统调试检测结果中，不符合现行国家消防技术标准的是（?）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"减压阀后静压为0.495Mpa，出水达到设计流量时，阀后动压为0.395Mpa",{"key":24,"text":364,"correct":22},"试验消火栓出水时，阀后动压为0.45Mpa",{"key":27,"text":366,"correct":29},"出水量为设计流量的150%时，阀后动压为0.23Mpa",{"key":31,"text":368,"correct":22},"在试验消火栓出水，设计流量出水和150%设计流量出水时，减压阀的噪音没有明显异常",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":24,"analysis":33},934954,"(2015年真题) 下列关于消防水枪抗跌落性能检查的说法中，正确的是（）。",[373,375,377,379],{"key":20,"text":374,"correct":22},"水枪应从距地（1.5±0.02）m高处自由跌落",{"key":24,"text":376,"correct":29},"水枪应从距地（2.0±0.02）m高处自由跌落",{"key":27,"text":378,"correct":22},"水枪应从距地（1.8±0.02）m高处自由跌落",{"key":31,"text":380,"correct":22},"水枪应从距地（2.2±0.02）m高处自由跌落",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":24,"analysis":33},934955,"(2015年真题) 根据《消防给水及消火栓系统技术规范》（GB50974-2014）的规定，下列关于室内消火栓系统日常维护管理的说法中，正确的是（）。",[385,387,389,391],{"key":20,"text":386,"correct":22},"每季度应该对消火栓进行一次严密性试验检查，发现有不正常的消火栓应及时更换",{"key":24,"text":388,"correct":29},"每季度应该对消火栓进行一次外观和漏水检查，发现有不正常的消火栓应及时更换",{"key":27,"text":390,"correct":22},"每季度应该对消火栓进行一次出水试验检查，发现有不正常的消火栓应及时更换",{"key":31,"text":392,"correct":22},"每季度应该对消火栓进行一次水压强度试验检查，发现有不正常的消火栓应及时更换",{"id":394,"libraryId":5,"type":48,"typeLabel":49,"stem":395,"options":396,"answer":407,"analysis":33},934956,"（2020年真题）某高层建筑，建筑高度为36米，总建筑面积为15000平方米，设置临时高压消防积水系统，对该消防积水系统检查的下列结果中，符合现行国家标准消防集水及消火栓系统技术规范的有（ ）。",[397,399,401,403,405],{"key":20,"text":398,"correct":29},"消防水泵控制柜设有机械应急启动装置，机械应急启动消防水泵，时间为30s",{"key":24,"text":400,"correct":22},"消防控制室设有消防水池水位显示装置，并具有高低水位报警功能，消防水池未设置现场就地水位显示装置",{"key":27,"text":402,"correct":29},"打开系统试水管道阀门后，68s消防水泵自动启动",{"key":31,"text":404,"correct":22},"两台消防水泵共用一条吸水管道，该条吸水管可通过两倍的系统设置流量",{"key":61,"text":406,"correct":29},"测试屋顶消火栓，出水压力栓口动压为0.35MPa","ACE",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":410,"options":411,"answer":20,"analysis":33},934957,"（2020年真题）某办公楼，建筑高度为50m，室外消火栓管道为环状管网，消防水池仅储存室内消防用水。对该建筑的消防水源及供水设施的下列检查结果中，不符合现行国家标准要求的是（ ）。",[412,414,416,418],{"key":20,"text":413,"correct":29},"室外消火栓管道只有1路与市政供水管道连接",{"key":24,"text":415,"correct":22},"高位水箱有效消防储水量为40m3",{"key":27,"text":417,"correct":22},"室内消火栓系统与自动喷水灭火系统合用消防水泵",{"key":31,"text":419,"correct":22},"消防水泵接合器与最近室外消火栓的距离为18m",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":24,"analysis":33},934958,"（2020年真题）根据现行国家标准《消防给水及消火栓系统技术规范》（GB50974）,对消火栓系统采用的組件、设备进行现场检验时，需要进行密封性能检查的部件是（ ）",[424,426,428,430],{"key":20,"text":425,"correct":22},"减压消火栓的减压装置",{"key":24,"text":427,"correct":29},"消火栓固定接口",{"key":27,"text":429,"correct":22},"消防水带",{"key":31,"text":431,"correct":22},"消火栓箱",{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":20,"analysis":33},934959,"（2020年真题）某消防技术服务机构对某高层建筑的消防水泵进行了检测。根据现行国家标准《消防给水及消火栓系统技术规范》（GB50974）,下列检测结果中,不符合规范要求的是（ ）",[436,438,440,442],{"key":20,"text":437,"correct":29},"以备用电源切换方式启动消防水泵,消防水泵投入正常运行用时65s",{"key":24,"text":439,"correct":22},"手动直接启动消防水泵,消防水泵投入正常运行用时20s",{"key":27,"text":441,"correct":22},"自动直接启动消防水泵,消防水泵投入正常运行用时25s",{"key":31,"text":443,"correct":22},"以备用泵切换方式启动消防水泵,消防水泵投入正常运行用时55s",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":27,"analysis":33},934960,"（2020年真题）某大型商业综合体地下-层，各餐饮场所的建筑面积均小于150m2。每家可容纳人数均少于70人，下列检查结果中不符合消防安全管理规则的是（ ）。",[448,450,452,454],{"key":20,"text":449,"correct":22},"消防电梯前室设置了消火栓",{"key":24,"text":451,"correct":22},"室内消火栓的布置间距最大为28m",{"key":27,"text":453,"correct":29},"消火栓箱内的消火栓栓口安装在门轴侧",{"key":31,"text":455,"correct":22},"消火栓箱门门的开启角度为155度",{"id":457,"libraryId":5,"type":48,"typeLabel":49,"stem":458,"options":459,"answer":470,"analysis":33},934961,"(2017年真题) 根据国家现行消防技术标准，对接入使用的自动喷水灭火系统需要每月进行检查维护的内容有（）。",[460,462,464,466,468],{"key":20,"text":461,"correct":29},"对控制阀门的铅封、锁链进行检查",{"key":24,"text":463,"correct":29},"消防水泵启动运转",{"key":27,"text":465,"correct":22},"对水源控制阀进行外观检查",{"key":31,"text":467,"correct":29},"利用末端试水装置对水流指示器试验",{"key":61,"text":469,"correct":29},"检查电磁阀并做启动试验","ABDE",{"id":472,"libraryId":5,"type":48,"typeLabel":49,"stem":473,"options":474,"answer":63,"analysis":33},934962,"(2016年真题) 对自动喷水灭火系统喷头的安装情况进行检查，下列说法中，正确的有（）",[475,477,479,481,483],{"key":20,"text":476,"correct":29},"喷头安装应在系统试压、冲洗合格后进行",{"key":24,"text":478,"correct":29},"同一隔间内不能同时安装3mm和5mm玻璃球洒水喷头",{"key":27,"text":480,"correct":29},"水平边墙型洒水喷头溅水盘与顶板的距离不应小于150mm，且不应大于300mm",{"key":31,"text":482,"correct":22},"湿式系统在吊顶下不应安装下垂型喷头",{"key":61,"text":484,"correct":22},"喷头的型号、规格，使用场所应符合规范规定",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":31,"analysis":33},934963,"（2019年真题）某高层酒店，设有自动喷水灭火系统，根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)，该酒店对自动喷水灭火系统维护保养的下列做法中，不符合规范要求的是（）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"每个季度检查一次室外阀门井中进水管上的控制阀门",{"key":24,"text":492,"correct":22},"对消防水池，高位消防水箱进行结构材料检查，安排在每年6月份进行",{"key":27,"text":494,"correct":22},"利用末端试水装置对水流指示器试验，安排在每月15日进行",{"key":31,"text":496,"correct":29},"每月手动启动消防水泵运转一次，每季度模拟自动控制的条件启动运转一次",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":24,"analysis":33},934964,"（2019年真题）某消防施工单位对某建筑的自动喷水系统组件进行进场检验。根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)，不属于喷头现场检验内容的是（）。",[501,503,505,507],{"key":20,"text":502,"correct":22},"喷头的型号、规格",{"key":24,"text":504,"correct":29},"喷头的工作压力",{"key":27,"text":506,"correct":22},"喷头的公称动作温度",{"key":31,"text":508,"correct":22},"喷头的响应时间指数(RTI)",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":31,"analysis":33},934965,"（2019年真题）某商场安装了自动喷水灭火系统,该商场管理人员在巡查中发现湿式报警阀组漏水故障无关的是（）",[513,515,517,519],{"key":20,"text":514,"correct":22},"阀瓣密闭垫老化或者损坏",{"key":24,"text":516,"correct":22},"报警阀组排水阀未完全关闭",{"key":27,"text":518,"correct":22},"阀瓣组件与阀座组件处有杂物",{"key":31,"text":520,"correct":29},"湿式报警阀组前供水控制阀未完全关闭",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":20,"analysis":33},934966,"（2019年真题）某消防工程施工单位对某建筑安装的自动喷水灭火系统进行调试，根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)。属于系统调试的是（）。",[525,527,529,531],{"key":20,"text":526,"correct":29},"排水设施调试",{"key":24,"text":528,"correct":22},"管道试压",{"key":27,"text":530,"correct":22},"管网冲洗",{"key":31,"text":532,"correct":22},"支吊架间距测量",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":20,"analysis":33},934967,"（2019年真题）某多层旅馆安装了自动喷水灭火系统，某消防技术服务机构对该系统进行检测。下列检测结果中，符合现行国家标准要求的是（）",[537,539,541,543],{"key":20,"text":538,"correct":29},"有水平吊顶的3.8m×3.8m的客房中间，设置一只下垂型标准覆盖面积洒水喷头",{"key":24,"text":540,"correct":22},"顶板为水平面的3.8m×3.8m的客房内，设置一只边墙型标准覆盖面积洒水喷头",{"key":27,"text":542,"correct":22},"客房内直立式边墙型标准覆盖面积洒水喷头溅水盘与顶板的距离为75mm",{"key":31,"text":544,"correct":22},"客房内直立式边墙型标准覆盖面积洒水喷头溅水盘与背墙的距离为150mm",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":24,"analysis":33},934968,"（2019年真题）根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)，对寒冷地区某汽车库的预作用自动喷水灭火系统进行检查。下列检查结果中，不符合规范要求的是（）。",[549,551,553,555],{"key":20,"text":550,"correct":22},"设置场所冬季室内温度长期低于0℃",{"key":24,"text":552,"correct":29},"配水管道未增设快速排气阀，排气阀入口前的控制阀为手动阀门",{"key":27,"text":554,"correct":22},"喷头选用直立型易熔合金喷头",{"key":31,"text":556,"correct":22},"气压表显示配水管道内的气压值为0.035MPa",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":31,"analysis":33},934969,"（2019年真题）某商场就建筑面积为20000㎡，地上营业厅设有吊顶，安装湿式自动喷水灭火系统，地下场所安装预作用自动喷水灭火系统，根据现行国家标准《自动喷水灭火系统设计规范》(GB5084)，关于该商场自动喷水灭火系统构成的说法，错误的是（）",[561,563,565,567],{"key":20,"text":562,"correct":22},"地上自动喷水灭火系统有湿式报警阀组、水流指示器、下垂型洒水喷头等组成",{"key":24,"text":564,"correct":22},"有吊顶部位预作用自动喷水灭火系统由预作用报警阀组、水流指示器、干式下垂型洒水喷头等组成",{"key":27,"text":566,"correct":22},"无吊顶部位预作用自动喷水灭火系统由预作用报警阀组、充气装置、水流指示器、直立型洒水喷头等组成",{"key":31,"text":568,"correct":29},"地上自动喷水灭火系统有湿式报警阀组、水流指示器、隐蔽式洒水喷头等组成",{"id":570,"libraryId":5,"type":48,"typeLabel":49,"stem":571,"options":572,"answer":583,"analysis":33},934970,"（2019年真题）根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)，关于自动喷水灭火系统洒水喷头的选型，正确的有（）。",[573,575,577,579,581],{"key":20,"text":574,"correct":22},"图书馆书库采用边墙型洒水喷头",{"key":24,"text":576,"correct":22},"总建筑面积为5000㎡的商场营业厅采用隐蔽式喷头",{"key":27,"text":578,"correct":29},"办公室吊顶下安装下垂型喷头",{"key":31,"text":580,"correct":29},"无吊顶的汽车库选用直立型快速响应喷头",{"key":61,"text":582,"correct":29},"印刷厂纸质品仓库采用早期抑制快速响应喷头","CDE",{"id":585,"libraryId":5,"type":48,"typeLabel":49,"stem":586,"options":587,"answer":598,"analysis":33},934971,"（2019年真题）根据现行国家标准《自动喷水灭火系统施工及验收规范》(GB50261)，自动喷水灭火系统调试前的必备条件有（）",[588,590,592,594,596],{"key":20,"text":589,"correct":29},"消防水池、消防水箱储存了设计要求的水量",{"key":24,"text":591,"correct":29},"系统供电正常",{"key":27,"text":593,"correct":22},"湿式系统官网已经放空",{"key":31,"text":595,"correct":22},"与系统联动的火灾自动报警系统处于调试阶段",{"key":61,"text":597,"correct":29},"消防气压给水设备的水位、气压符合设计要求","ABE",{"id":600,"libraryId":5,"type":48,"typeLabel":49,"stem":601,"options":602,"answer":610,"analysis":33},934972,"(2017年真题) 在自动喷水灭火系统设备和组件安装完成后应对系统进行测试，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB50261，系统调试主控项目应包括的内容有（）",[603,605,606,607,608],{"key":20,"text":604,"correct":22},"电动阀调试",{"key":24,"text":105,"correct":29},{"key":27,"text":111,"correct":29},{"key":31,"text":526,"correct":29},{"key":61,"text":609,"correct":29},"稳压泵调试","BCDE",{"id":612,"libraryId":5,"type":15,"typeLabel":16,"stem":613,"options":614,"answer":31,"analysis":33},934973,"(2017年真题) 某消防设施检测机构的人员在对一商场的自动喷水灭火系统进行检测时,打开系统末端试水装置,在达到规定流量时水流指示器不动作,下列故障原因中,可以排除的是(??)",[615,617,619,621],{"key":20,"text":616,"correct":22},"浆片被管腔内杂物卡阻",{"key":24,"text":618,"correct":22},"调整螺母与触头未调试到位",{"key":27,"text":620,"correct":22},"连接水流指示器的电路脱落",{"key":31,"text":622,"correct":29},"报警阀前端的水源控制阀未完全打开",{"id":624,"libraryId":5,"type":15,"typeLabel":16,"stem":625,"options":626,"answer":27,"analysis":33},934974,"(2017年真题) 某消防工程施工单位对自动喷水灭火系统闭式喷头进行密封性能试验，下列试验压力和保压时间的做法中， 正确的是（??）。",[627,629,631,633],{"key":20,"text":628,"correct":22},"试验压力2.0MPa，保压时间5min",{"key":24,"text":630,"correct":22},"试验压力3.0MPa，保压时间1min",{"key":27,"text":632,"correct":29},"试验压力3.0MPa，保压时间3min",{"key":31,"text":634,"correct":22},"试验压力2.0MPa，保压时间2min",[636,639,642,645,648,651],{"id":15,"name":637,"category":7,"favorite":638},"领导干部任职前廉政法规知识测试题",92,{"id":640,"name":641,"category":7,"favorite":15},595,"建筑结构与设备",{"id":643,"name":644,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":646,"name":647,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":649,"name":650,"category":7,"favorite":8},534,"BIM工程师",{"id":652,"name":650,"category":7,"favorite":8},535]