[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-59":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":653},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,59,50,2974,[13,34,46,58,70,82,94,106,118,136,150,165,180,189,201,216,227,242,253,265,277,289,301,313,325,337,349,361,373,385,397,411,424,438,453,467,482,496,509,522,536,551,565,577,589,601,613,625,634,642],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},937597,1,"单选题","下列关于消防水枪密封性能检查的说法，正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","加压至最大工作压力的1.5倍，保压2min",true,{"key":24,"text":25,"correct":26},"B","加压至最大工作压力的1.5倍，保压3min",false,{"key":28,"text":29,"correct":26},"C","加压至最大工作压力的2倍，保压2min",{"key":31,"text":32,"correct":26},"D","加压至最大工作压力的2倍，保压3min","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},937598,"下列说法中，不属于室内消火栓的维护管理内容的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":26},"检查消火栓和消防卷盘供水闸阀是否渗漏水",{"key":24,"text":41,"correct":22},"检查栓体外表油漆有无脱落，有无锈蚀",{"key":28,"text":43,"correct":26},"检查报警按钮、指示灯及控制线路，应功能正常、无故障",{"key":31,"text":45,"correct":26},"对消防水枪、水带、消防卷盘等进行检查，全部附件应齐全完好，卷盘转动灵活",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},937599,"室外消火栓的分类按其进水口连接形式可分为承插式和法兰式两种，其中法兰式的消火栓公称压力为（ ）MPa。",[50,52,54,56],{"key":20,"text":51,"correct":26},"1.0",{"key":24,"text":53,"correct":26},"1.5",{"key":28,"text":55,"correct":26},"2.4",{"key":31,"text":57,"correct":22},"1.6",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},937600,"下列关于卡式消防接口抗跌落试验的说法正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"将接口的最低点离地面（1.5±0.05）m的高度，自由跌落到混凝土地面上，反复进行五次",{"key":24,"text":65,"correct":26},"将接口的最低点离地面（2±0.02）m的高度，自由跌落到混凝土地面上，反复进行两次",{"key":28,"text":67,"correct":26},"将接口的最高点离地面（1.5+0.05）m的高度，自由跌落到混凝土地面上，反复进行五次",{"key":31,"text":69,"correct":26},"将接口的最高点离地面（2±0.02）m的高度，自由跌到混凝土地面上，反复进行两次",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},937601,"下列消防水枪的分类中，不属于按照喷水方式分类的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"消防撞击式喷雾水枪",{"key":24,"text":77,"correct":26},"消防开关直流水枪",{"key":28,"text":79,"correct":26},"球阀转换式消防多用水枪",{"key":31,"text":81,"correct":22},"高压水枪",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},937602,"消防水枪的抗跌落性能检查，从离地（ ）m高处（从消防水枪的最低点算起）自由跌落到混凝土地面上，消防水枪在每个位置各跌落（ ）次。",[86,88,90,92],{"key":20,"text":87,"correct":26},"2.0±0.05,5",{"key":24,"text":89,"correct":26},"1.5±0.05,2",{"key":28,"text":91,"correct":22},"2.0±0.02,2",{"key":31,"text":93,"correct":26},"1.5±0.05,5",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},937603,"每（ ）应对消火栓进行一次外观检查，发现有不正常的消火栓应及时更换。",[98,100,102,104],{"key":20,"text":99,"correct":26},"天",{"key":24,"text":101,"correct":26},"周",{"key":28,"text":103,"correct":26},"月",{"key":31,"text":105,"correct":22},"季度",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},937604,"下列关于消火栓系统部件的进场检验数量及产品性能要求说法，不正确的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"旋转型消火栓其内部构造应合理，转动部件应为铜或不锈钢",{"key":24,"text":113,"correct":22},"消火栓固定接口性能检查数量从每批中抽查1%，但不应少于10个",{"key":28,"text":115,"correct":26},"外观检查应按安装总数全数检查",{"key":31,"text":117,"correct":26},"消火栓铸铁阀体外部应涂红色油漆，内表面应涂防锈漆，手轮应涂黑色油漆",{"id":119,"libraryId":5,"type":120,"typeLabel":121,"stem":122,"options":123,"answer":135,"analysis":33},937605,2,"多选题","地下消火栓应每季进行一次检查保养，内容主要包括（ ）。",[124,126,128,130,132],{"key":20,"text":125,"correct":22},"用专用扳手转动消火栓启闭杆，观察其灵活性，必要时加注润滑油",{"key":24,"text":127,"correct":26},"检查消火栓和消防卷盘供水闸阀是否漏水，若漏水及时更换密封圈",{"key":28,"text":129,"correct":22},"检查栓体外表油漆有无脱落，有无锈蚀，如有应及时修补",{"key":31,"text":131,"correct":22},"随时消除消火栓井周围及井内积存的杂物",{"key":133,"text":134,"correct":26},"E","检查报警阀按钮，指示灯及控制线路，应功能正常、无故障","ACD",{"id":137,"libraryId":5,"type":120,"typeLabel":121,"stem":138,"options":139,"answer":149,"analysis":33},937606,"室内消火栓箱内应经常保持清洁、干燥，防止锈蚀、碰伤或其他损坏。每半年至少进行一次全面检查维修，主要内容有（ ）。",[140,141,143,145,147],{"key":20,"text":127,"correct":22},{"key":24,"text":142,"correct":22},"对消防水枪、水带、消防卷盘及其它进行检查，全部附件应齐全完好，卷盘转动灵活",{"key":28,"text":144,"correct":26},"入冬前检查消火栓的防冻设施是否完好",{"key":31,"text":146,"correct":22},"消火栓箱及箱内装配的部件外观无破损、涂层无脱落，箱门玻璃完好无缺",{"key":133,"text":148,"correct":22},"对消火栓、供水阀门及消防卷盘等所有转动部位应定期加注润滑油","ABDE",{"id":151,"libraryId":5,"type":120,"typeLabel":121,"stem":152,"options":153,"answer":164,"analysis":33},937607,"下列关于室内外消火栓系统设备和设施的维护管理，需要每个季度检查或保养的是（ ）。",[154,156,158,160,162],{"key":20,"text":155,"correct":22},"室外地下消火栓检查保养",{"key":24,"text":157,"correct":26},"室外地上消火栓出水试验",{"key":28,"text":159,"correct":26},"室内消火栓检查维修",{"key":31,"text":161,"correct":22},"室外消火栓进水管控制阀门检查",{"key":133,"text":163,"correct":26},"铅封和锁链的检查","AD",{"id":166,"libraryId":5,"type":120,"typeLabel":121,"stem":167,"options":168,"answer":179,"analysis":33},937608,"室内消火栓的分类可以按出水口形式、按栓阀数量和按结构形式等。下列属于按结构形式对室内消火栓分类的是（ ）。",[169,171,173,175,177],{"key":20,"text":170,"correct":26},"单出口室内消火栓",{"key":24,"text":172,"correct":26},"双栓阀",{"key":28,"text":174,"correct":22},"直角出口型室内消火栓",{"key":31,"text":176,"correct":22},"旋转型室内消火栓",{"key":133,"text":178,"correct":22},"旋转减压稳压型室内消火栓","CDE",{"id":181,"libraryId":5,"type":120,"typeLabel":121,"stem":182,"options":183,"answer":179,"analysis":33},937609,"室内消火栓有多种分类方式，下列属于按结构形式对室内消火栓进行分类的是（ ）。",[184,185,186,187,188],{"key":20,"text":170,"correct":26},{"key":24,"text":172,"correct":26},{"key":28,"text":174,"correct":22},{"key":31,"text":176,"correct":22},{"key":133,"text":178,"correct":22},{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":28,"analysis":33},937610,"进行消火栓安装前检查时，多处采用小刀轻刮的方法检查相应组件的材质，以下说法中不正确的是（ ）。",[193,195,197,199],{"key":20,"text":194,"correct":26},"检查室外消火栓接口时，用小刀轻刮外螺纹固定接口和吸水管接口，目测其本体材料应由铜或不锈钢材料制造",{"key":24,"text":196,"correct":26},"检查室内消火栓箱时：用小刀轻刮箱体内外表面涂层，查看是否经过防腐处理，使用千分尺进行测量，箱体应使用厚度不小于1.2mm的薄钢板或铝合金材料制造，箱门玻璃厚度不小于4.0mm",{"key":28,"text":198,"correct":22},"检查消防水枪时：使用小刀轻刮水枪铝制件表面，检查是否静电喷塑防腐处理。",{"key":31,"text":200,"correct":26},"检查室内消火栓接口时：使用小刀轻刮接口表面，目测，表面应进行过阳极氧化处理或静电喷塑防腐处理",{"id":202,"libraryId":5,"type":120,"typeLabel":121,"stem":203,"options":204,"answer":215,"analysis":33},937611,"室外消火栓系统主要包括（ ）。",[205,207,209,211,213],{"key":20,"text":206,"correct":22},"消防水池",{"key":24,"text":208,"correct":22},"消防水泵",{"key":28,"text":210,"correct":22},"室外消火栓",{"key":31,"text":212,"correct":26},"报警控制设备",{"key":133,"text":214,"correct":26},"稳压罐","ABC",{"id":217,"libraryId":5,"type":120,"typeLabel":121,"stem":218,"options":219,"answer":226,"analysis":33},937612,"室内消火栓按结构型式可分为（ ）。",[220,221,222,224,225],{"key":20,"text":174,"correct":22},{"key":24,"text":176,"correct":22},{"key":28,"text":223,"correct":26},"单栓阀室内消火栓",{"key":31,"text":170,"correct":26},{"key":133,"text":178,"correct":22},"ABE",{"id":228,"libraryId":5,"type":120,"typeLabel":121,"stem":229,"options":230,"answer":241,"analysis":33},937613,"下列关于消防水带检查的描述中正确的是（ ）。",[231,233,235,237,239],{"key":20,"text":232,"correct":22},"消防水带用卷尺测量（不包括水带接口）小于规定长度1m以上的判断为不合格",{"key":24,"text":234,"correct":26},"截取1.2m长的水带，手动或电动试压泵平稳加压至试验压力试验压力为工作压力的1.2倍",{"key":28,"text":236,"correct":22},"截取1.2m长的水带，手动或电动试压泵平稳加压至试验压力试验压力为工作压力的1.5倍",{"key":31,"text":238,"correct":26},"加压至试验压力后保压2min，检查是否有渗漏现象，有渗漏则判定为不合格",{"key":133,"text":240,"correct":22},"加压至试验压力后保压5min，检查是否有渗漏现象，有渗漏则判定为不合格","ACE",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":20,"analysis":33},937614,"下列不属于室内消火栓组成部分的是（ ）。",[246,248,250,251],{"key":20,"text":247,"correct":22},"市政供水管网",{"key":24,"text":249,"correct":26},"消防给水设施",{"key":28,"text":212,"correct":26},{"key":31,"text":252,"correct":26},"系统附件",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":28,"analysis":33},937615,"适用于气温较高地区的消火栓是（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":26},"承插式消火栓",{"key":24,"text":260,"correct":26},"法兰式消火栓",{"key":28,"text":262,"correct":22},"地上式消火栓",{"key":31,"text":264,"correct":26},"地下式消火栓",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":20,"analysis":33},937616,"下列符合消火栓箱检查验收规定的是（ ）。",[269,271,273,275],{"key":20,"text":270,"correct":22},"栓口出水方向宜向下或与设置消火栓的墙面呈90°角，栓口不应安装在门轴侧",{"key":24,"text":272,"correct":26},"如设计未要求，栓口中心距地面应为1.1m，但每栋建筑物应一致，允许偏差±10mm",{"key":28,"text":274,"correct":26},"阀门的设置位置应便于操作使用，阀门的中心距箱侧面为100mm",{"key":31,"text":276,"correct":26},"消火栓箱体安装的垂直度允许偏差为±5mm",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":33},937617,"下列关于室外消火栓的安装前检查的说法中，不正确的是（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":26},"对照产品的检验报告，合格的室外消火栓应在阀体或阀盖上铸出型号、规格和商标且应与检验报告描述一致",{"key":24,"text":284,"correct":22},"用小刀轻刮外螺纹固定接口和吸水管接口，目测外螺纹固定接口和吸水管接口的本体材料应由铜或铜合金制造",{"key":28,"text":286,"correct":26},"室外消火栓应有自动排放余水装置",{"key":31,"text":288,"correct":26},"栓阀座应用铸造铜合金，阀杆螺母材料性能应不低于黄铜",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":33},937618,"消防水带的安装前检查，检查水带长度时，将整卷水带打开，用卷尺测量其总长度，测量时应不包括水带的接口，将测得的数据与有衬里消防水带的标称长度进行对比，如水带长度小于（ ）的，则可以判为该产品为不合格。",[293,295,297,299],{"key":20,"text":294,"correct":26},"水带长度规格5%以上",{"key":24,"text":296,"correct":26},"水带长度规格10%",{"key":28,"text":298,"correct":22},"水带长度规格1m以上",{"key":31,"text":300,"correct":26},"水带长度规格2m以上",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":20,"analysis":33},937619,"消防水带安装前的压力试验：截取（ ）长的水带，使用手动试压泵或电动试压泵平稳加压至试验压力，保压（ ）。检查是否有渗漏现象，有渗漏则不合格。在试验压力状态下，继续加压，升压至试样爆破，其爆破时压力应不小于水带工作压力的（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"1.2m，5min，3倍",{"key":24,"text":308,"correct":26},"1.0m，3min，1.5倍",{"key":28,"text":310,"correct":26},"1.5m，10min，1.1倍",{"key":31,"text":312,"correct":26},"1.2m，3min，3倍",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":31,"analysis":33},937620,"关于消防设备材质检查要求，不正确的是（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":26},"室外消火栓栓阀座应用铸造铜合金，阀杆螺母材料性能应不低于黄铜",{"key":24,"text":320,"correct":26},"室内消火栓阀座及阀杆螺母材料性能应不低于黄铜材料，阀杆本体材料性能应不低于铅黄铜",{"key":28,"text":322,"correct":26},"室内消火栓箱门材料可采用全钢型、钢框镶玻璃型、铝合金框镶玻璃型",{"key":31,"text":324,"correct":22},"合格的消防水枪铸件表面应无结疤、裂纹及孔眼，表面不进行阳极氧化处理",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":24,"analysis":33},937621,"对某“8\"型消防水带进行检查，下列做法和检查结果不符合规定的是（ ）。",[329,331,333,335],{"key":20,"text":330,"correct":26},"截取1.2m长的水带，使用电动试压泵加压",{"key":24,"text":332,"correct":22},"在试验压力下保压3min，检查无渗漏现象，判定合格",{"key":28,"text":334,"correct":26},"水带的试验压力为1.2MPa",{"key":31,"text":336,"correct":26},"水带的爆破压力为2.4MPa",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":28,"analysis":33},937622,"关于室外消火栓的检查内容，其中不包括（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":26},"消防接口",{"key":24,"text":344,"correct":26},"产品标识",{"key":28,"text":346,"correct":22},"水带",{"key":31,"text":348,"correct":26},"材料",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":31,"analysis":33},937623,"下列消火栓箱的分类型式属于按水带的安置方式划分的是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":26},"明装式",{"key":24,"text":356,"correct":26},"右开门式",{"key":28,"text":358,"correct":26},"半暗装式",{"key":31,"text":360,"correct":22},"卷盘式",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},937624,"室外消火栓按其进水口的公称通径可分为100mm和150mm两种，进水口公称通径为100mm的消火栓，其吸水管出水口应选用规格为（ ）mm的消防接口。",[365,367,369,371],{"key":20,"text":366,"correct":26},"65",{"key":24,"text":368,"correct":26},"80",{"key":28,"text":370,"correct":22},"100",{"key":31,"text":372,"correct":26},"150",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":31,"analysis":33},937625,"对某厂区的室外地下式消火栓进行检查，下列检查结果不符合规范要求的是（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":26},"消火栓顶部出水口正对井口",{"key":24,"text":380,"correct":26},"顶部出水口与消防井盖底面的距离为0.3m",{"key":28,"text":382,"correct":26},"消火栓井的直径为1.6m",{"key":31,"text":384,"correct":22},"消火栓设置了两个直径为65mm的栓口",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":28,"analysis":33},937626,"下列关于消防水带压力试验的说法，不正确的是（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":26},"截取1.2m长的消防水带做试验",{"key":24,"text":392,"correct":26},"加压至试验压力，保压5min",{"key":28,"text":394,"correct":22},"爆破压力应不小于消防水带试验压力的3倍",{"key":31,"text":396,"correct":26},"常用8型消防水带的试验压力为1.2MPa，爆破压力不小于2.4MPa",{"id":398,"libraryId":5,"type":120,"typeLabel":121,"stem":399,"options":400,"answer":215,"analysis":33},937627,"下列关于消火栓的分类和检查的描述中错误的是（ ）。",[401,403,405,407,409],{"key":20,"text":402,"correct":22},"室外消火栓有地上式、地下式和半地下式",{"key":24,"text":404,"correct":22},"室外消火栓根据进口连接形式可以分为承插式和法兰式，其中承插式可承受的压力比法兰式大",{"key":28,"text":406,"correct":22},"室外地上式消火栓必须是一个直径为100mm和两个直径为65mm的栓口",{"key":31,"text":408,"correct":26},"室外地下式消火栓是直径为100mm和65mm的栓口各一个的栓口",{"key":133,"text":410,"correct":26},"室外地下式消火栓井内径不应小于1.5m",{"id":412,"libraryId":5,"type":120,"typeLabel":121,"stem":413,"options":414,"answer":215,"analysis":33},937628,"消防水枪按照喷水方式分为（ ）。",[415,417,419,421,423],{"key":20,"text":416,"correct":22},"直流水枪",{"key":24,"text":418,"correct":22},"喷雾水枪",{"key":28,"text":420,"correct":22},"多用途水枪",{"key":31,"text":422,"correct":26},"低压水枪",{"key":133,"text":81,"correct":26},{"id":425,"libraryId":5,"type":120,"typeLabel":121,"stem":426,"options":427,"answer":215,"analysis":33},937629,"下列有关消火栓水枪的检查，正确的是（ ）。",[428,430,432,434,436],{"key":20,"text":429,"correct":22},"水枪在喷嘴垂直朝上、垂直朝下、一级水枪轴线处于水平三个位置跌落两次，出现断裂或不能正常操作使用的，判为不合格",{"key":24,"text":431,"correct":22},"水枪铸件表面应无结疤、裂纹、孔眼",{"key":28,"text":433,"correct":22},"封闭水枪出水端，排气加压至最大工作压力的1.5倍，保压2min，不应出现裂纹，渐裂或影响正常使用的残余变形",{"key":31,"text":435,"correct":26},"使用小刀轻刮水枪制作表面，看是否为铜制材料",{"key":133,"text":437,"correct":26},"从离地面（1.5±0.05）m高度，进行消防水枪的抗跌落性能检查",{"id":439,"libraryId":5,"type":120,"typeLabel":121,"stem":440,"options":441,"answer":452,"analysis":33},937630,"下列关于消火栓的检查内容，正确的是（ ）。",[442,444,446,448,450],{"key":20,"text":443,"correct":22},"现场检查时可以用小刀轻刮箱体内外表面涂层，箱体应经过防腐处理",{"key":24,"text":445,"correct":26},"栓箱箱门正面应以直观、醒目、匀整的字体标注“消火栓”字样，且字体不得小于：高100mm，宽70mm",{"key":28,"text":447,"correct":22},"设置门锁的栓箱，除箱门安装玻璃者及能被击碎的透明材料外，均应设置箱门紧急开启的手动机构，应保证在没有钥匙的情况下开启灵活、可靠",{"key":31,"text":449,"correct":26},"箱门开启角度不得小于160°，并无卡阻现象",{"key":133,"text":451,"correct":26},"使用千分尺进行测量，箱体应使用厚度不小于1.2mm的薄钢板或铝合金材料制造，箱门玻璃厚度不小于5.0mm","AC",{"id":454,"libraryId":5,"type":120,"typeLabel":121,"stem":455,"options":456,"answer":149,"analysis":33},937631,"下列关于室内外消火栓系统管道安装的描述中不正确的是（ ）。",[457,459,461,463,465],{"key":20,"text":458,"correct":22},"室外消火栓系统管道在焊接后应清除接口处的浮锈、污垢及油脂",{"key":24,"text":460,"correct":22},"室外消火栓安装前，管件内外壁均涂沥青冷底子1遍，外壁需另加热沥青2遍、面漆2遍",{"key":28,"text":462,"correct":26},"室内消火栓管道穿梁及地下室剪力墙、水池等，应在预埋金属管中穿过",{"key":31,"text":464,"correct":22},"水压强度试验的测试点应设在系统管网的最高点",{"key":133,"text":466,"correct":22},"室内消火栓系统管井的消防立管安装采用从上到下的安装方法",{"id":468,"libraryId":5,"type":120,"typeLabel":121,"stem":469,"options":470,"answer":481,"analysis":33},937632,"室外消火栓的检测验收主要包括（ ）。",[471,473,475,477,479],{"key":20,"text":472,"correct":26},"管道安装应根据设计要求使用管材，按压力要求选用管材",{"key":24,"text":474,"correct":22},"室外消火栓的选型、规格、数量、安装位置应符合设计要求",{"key":28,"text":476,"correct":22},"室外消火栓水量及压力应满足要求",{"key":31,"text":478,"correct":22},"室外消火栓应设置明显的永久性固定标志",{"key":133,"text":480,"correct":22},"同一建筑物内设置的室外消火栓应采用统一规格的栓口及配件","BCDE",{"id":483,"libraryId":5,"type":120,"typeLabel":121,"stem":484,"options":485,"answer":149,"analysis":33},937633,"消火栓箱的检查内容主要包括（ ）。",[486,488,490,492,494],{"key":20,"text":487,"correct":22},"箱门",{"key":24,"text":489,"correct":22},"水带安置",{"key":28,"text":491,"correct":26},"排放余水装置",{"key":31,"text":493,"correct":22},"外观质量和标志",{"key":133,"text":495,"correct":22},"器材的配置和性能",{"id":497,"libraryId":5,"type":120,"typeLabel":121,"stem":498,"options":499,"answer":241,"analysis":33},937634,"下列有关消火栓管道安装要求描述正确的是（ ）。",[500,502,504,506,507],{"key":20,"text":501,"correct":22},"管道穿梁及地下室剪力墙、水池等，应装设预埋金属管",{"key":24,"text":503,"correct":26},"安装顺序一般是垂直管、横管、分支管、干管、主干管",{"key":28,"text":505,"correct":22},"管道对口焊缝上不得开口焊接支管，焊口不得安装在支吊架位置上",{"key":31,"text":464,"correct":26},{"key":133,"text":508,"correct":22},"管井的消防立管安装采用从下至上的安装方法",{"id":510,"libraryId":5,"type":120,"typeLabel":121,"stem":511,"options":512,"answer":521,"analysis":33},937635,"室外消火栓按照进水口的公称通径可分为（ ）mm，一定进水口公称通径的消火栓，其吸水管出水口、水带出水口应选用一定规格的消防接口。",[513,515,516,517,519],{"key":20,"text":514,"correct":26},"50",{"key":24,"text":370,"correct":22},{"key":28,"text":372,"correct":22},{"key":31,"text":518,"correct":26},"200",{"key":133,"text":520,"correct":26},"250","BC",{"id":523,"libraryId":5,"type":120,"typeLabel":121,"stem":524,"options":525,"answer":149,"analysis":33},937636,"对某民用建筑的室内消火栓进行检查，下列检查结果中不符合规范要求的有（ ）。",[526,528,530,532,534],{"key":20,"text":527,"correct":22},"室内消火栓均未设置明显的固定标志",{"key":24,"text":529,"correct":22},"室内消火栓的安装高度为0.7m",{"key":28,"text":531,"correct":26},"室内消火栓栓口出水方向与设置消火栓的墙面成90°角",{"key":31,"text":533,"correct":22},"采用DN65室内消火栓，屋顶试验消火栓未设置压力表",{"key":133,"text":535,"correct":22},"室内消火栓栓口安装在门轴侧",{"id":537,"libraryId":5,"type":120,"typeLabel":121,"stem":538,"options":539,"answer":550,"analysis":33},937637,"下列关于室内消火栓产品材料及涂装的说法，不正确的有（ ）。",[540,542,544,546,548],{"key":20,"text":541,"correct":26},"室内消火栓阀座的材料性能应不低于黄铜材料",{"key":24,"text":543,"correct":22},"阀杆螺母材料的材料性能应不低于铅黄铜材料",{"key":28,"text":545,"correct":26},"铸铁阀体外部应涂红色漆",{"key":31,"text":547,"correct":22},"阀杆本体材料性能应不低于黄铜",{"key":133,"text":549,"correct":26},"手轮应涂黑色漆","BD",{"id":552,"libraryId":5,"type":120,"typeLabel":121,"stem":553,"options":554,"answer":164,"analysis":33},937638,"下列关于消火栓系统维护管理的说法，不正确的有（ ）。",[555,557,559,561,563],{"key":20,"text":556,"correct":22},"每年应监测市政给水管网的压力和供水能力",{"key":24,"text":558,"correct":26},"每月应对高位消防水箱的水位等进行一次检测",{"key":28,"text":560,"correct":26},"每日应对柴油机消防水泵的启动电池的电量进行检测",{"key":31,"text":562,"correct":22},"每天应对消防储水设施进行室内温度和水温检测",{"key":133,"text":564,"correct":26},"每季度应对消火栓进行一次漏水检查，发现有不正常的消火栓应及时更换",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":28,"analysis":33},937639,"干式系统，预作用系统均对配水管道的充水时间有限制要求，规定充水时间的目的是（ ）。",[569,571,573,575],{"key":20,"text":570,"correct":26},"迅速充水更有利于排气",{"key":24,"text":572,"correct":26},"充水时间的规定可以防止系统误喷",{"key":28,"text":574,"correct":22},"充水时间的规定主要是要求系统启动后立即喷水",{"key":31,"text":576,"correct":26},"充水越快，水头损失越小",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":28,"analysis":33},937640,"某3层商业建筑，采用湿式自动喷水灭火系统保护，共设计有2800个喷头保护吊顶下方空间。该建筑自动喷水灭火系统报警阀组的设置数量不应少于（ ）个。",[581,583,585,587],{"key":20,"text":582,"correct":26},"2",{"key":24,"text":584,"correct":26},"3",{"key":28,"text":586,"correct":22},"4",{"key":31,"text":588,"correct":26},"5",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":28,"analysis":33},937641,"系统的周期性检查维护中，每季度至少进行一次检查与维护的是（ ）。",[593,595,597,599],{"key":20,"text":594,"correct":26},"喷头完好情况",{"key":24,"text":596,"correct":26},"水源供水能力测试",{"key":28,"text":598,"correct":22},"水流指示器报警试验",{"key":31,"text":600,"correct":26},"系统联动测试",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":31,"analysis":33},937642,"自动喷水灭火系统为控制因建筑高差较大造成的超压，通常采用分区供水或者在系统相应管段上安装（ ），以控制管道静压。",[605,607,609,611],{"key":20,"text":606,"correct":26},"泄水阀",{"key":24,"text":608,"correct":26},"压力开关",{"key":28,"text":610,"correct":26},"报警阀组",{"key":31,"text":612,"correct":22},"减压阀",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":24,"analysis":33},937643,"自动喷水灭火系统组件安装前检查中，对喷头现场检查要求玻璃球喷头玻璃球色标与对应公称动作温度对应正确，玻璃球色标为红色，其对应的公称动作温度为（ ）℃。",[617,619,621,623],{"key":20,"text":618,"correct":26},"57",{"key":24,"text":620,"correct":22},"68",{"key":28,"text":622,"correct":26},"79",{"key":31,"text":624,"correct":26},"93",{"id":626,"libraryId":5,"type":15,"typeLabel":16,"stem":627,"options":628,"answer":28,"analysis":33},937644,"一自动喷水系统，安装300只闭式喷头。组件安装前检查中，闭式喷头要做密封性能试验。密封性试验应抽取的喷头（ ）只。",[629,630,631,632],{"key":20,"text":584,"correct":26},{"key":24,"text":586,"correct":26},{"key":28,"text":588,"correct":22},{"key":31,"text":633,"correct":26},"6",{"id":635,"libraryId":5,"type":15,"typeLabel":16,"stem":636,"options":637,"answer":20,"analysis":33},937645,"自动喷水系统组件安装前检查中要求随机抽取（ ）个喷头（带有运输护帽的摘下护帽）进行质量偏差检查。",[638,639,640,641],{"key":20,"text":584,"correct":22},{"key":24,"text":586,"correct":26},{"key":28,"text":588,"correct":26},{"key":31,"text":633,"correct":26},{"id":643,"libraryId":5,"type":15,"typeLabel":16,"stem":644,"options":645,"answer":20,"analysis":33},937646,"为了保证报警阀组及其附件的安装质量和基本性能要求，报警阀组到场后，重点检查（验）其附件配置、外观标识、外观质量、渗漏试验和报警阀结构等内容。其中报警阀结构检查中，要求阀体上设有放水口，放水口的公称直径不小于（ ）mm。",[646,648,650,652],{"key":20,"text":647,"correct":22},"20",{"key":24,"text":649,"correct":26},"30",{"key":28,"text":651,"correct":26},"40",{"key":31,"text":514,"correct":26},[654,657,660,663,666,669],{"id":15,"name":655,"category":7,"favorite":656},"领导干部任职前廉政法规知识测试题",92,{"id":658,"name":659,"category":7,"favorite":15},595,"建筑结构与设备",{"id":661,"name":662,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":664,"name":665,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":667,"name":668,"category":7,"favorite":8},534,"BIM工程师",{"id":670,"name":668,"category":7,"favorite":8},535]