[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-58":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":678},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,58,50,2974,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,220,235,250,265,278,293,307,321,336,351,365,380,394,408,423,438,453,467,482,496,510,522,534,546,558,573,585,597,609,618,630,642,654,666],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},937547,1,"单选题","组装式水泵接合器的安装，应按（ ）的顺序进行，止回阀的安装方向应使消防用水能从水泵接合器进入系统，整体式水泵接合器的安装按其使用安装说明书进行。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","接口、本体、连接管、止回阀、安全阀、放空管、控制阀",true,{"key":24,"text":25,"correct":26},"B","接口、本体、连接管、安全阀、放空管、控制阀、止回阀",false,{"key":28,"text":29,"correct":26},"C","本体、接口、连接管、止回阀、安全阀、放空管、控制阀",{"key":31,"text":32,"correct":26},"D","接口、本体、连接管、安全阀、止回阀、放空管、控制阀","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},937548,"对于消防给水及消火栓系统的工程施工质量缺陷，当严重缺陷项A=0，重缺陷项B≤2，且（ ）时，竣工验收判定为合格。（C为轻缺陷项）",[38,40,42,44],{"key":20,"text":39,"correct":26},"B+C=6",{"key":24,"text":41,"correct":22},"B+C≤6",{"key":28,"text":43,"correct":26},"B+C≤20%",{"key":31,"text":45,"correct":26},"B+C=20%",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},937549,"某麻纺厂粗加工厂房设置临时高压消防给水系统，王某负责给水系统的日常检查、维护与管理。下列符合消防给水管网阀门维护管理规定的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"每月对电动阀和电磁阀的供电和启闭性能进行检测",{"key":24,"text":53,"correct":26},"每周对水源控制阀进行外观检查，并应保证系统处于无故障状态",{"key":28,"text":55,"correct":26},"每年对系统所有的末端试水阀和报警阀的放水试验阀进行一次放水试验",{"key":31,"text":57,"correct":26},"每年对室外阀门井中进水管上的控制阀进行一次检查，并应核实其处于全开启状态",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},937550,"下列给水管网支吊架的安装不符合规范规定的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"架空管道支架、吊架、防晃（固定）支架的安装固定牢固",{"key":24,"text":65,"correct":22},"配水支管每15m长度内设一个防晃支架，当管径不大于DN50mm时不设",{"key":28,"text":67,"correct":26},"设计的吊架在管道的每一支撑点处能承受5倍于充满水的管重",{"key":31,"text":69,"correct":26},"当管道穿梁安装时，穿梁处做一个吊架",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},937551,"下列关于水泵接合器安装的说法中，错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"组装式水泵接合器的安装，应按接口、本体、连接管、止回阀、安全阀、放空管、控制阀的顺序进行",{"key":24,"text":77,"correct":26},"水泵接合器接口的位置安装在距离室外消火栓20m处",{"key":28,"text":79,"correct":22},"为便于人员观察，墙壁水泵接合器可安装在玻璃幕墙下方",{"key":31,"text":81,"correct":26},"地下消防水泵接合器的安装，应使进水口与井盖底面的距离不大于0.4m，且不应小于井盖的半径",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":31,"analysis":33},937552,"南方某民用建筑的室内消防给水系统采用消防水池作为消防水源，并采用两路供水，消防水池储存室内消防用水（不供消防车取水），下列关于该消防水池的说法，正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"该消防水池应设取水口（井）",{"key":24,"text":89,"correct":26},"该消防水池不可与生活用水或其他用水合用",{"key":28,"text":91,"correct":26},"该消防水池应采取相应的防冻措施",{"key":31,"text":93,"correct":22},"该消防水池可减去持续灭火时间内的补水容积",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},937553,"某工业建筑的消防给水系统采用井水作为消防水源，下列不属于井水作为两路消防供水条件的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"水井不应少于两眼",{"key":24,"text":101,"correct":26},"每眼井的深井泵必须采用一级供电负荷",{"key":28,"text":103,"correct":22},"每眼井的深井泵均应设置备用泵",{"key":31,"text":105,"correct":26},"其最不利水位应满足水泵吸水要求",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},937554,"消防水泵安装前应检查产品合格证，以及其规格、型号和性能与设计要求是否一致，检查比例应不少于（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"30%",{"key":24,"text":113,"correct":26},"50%",{"key":28,"text":115,"correct":26},"80%",{"key":31,"text":117,"correct":22},"100%",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},937555,"对某在建工程的消防水泵进行检查，下列检查结果不符合规范要求的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"水泵外壳的材质为球墨铸铁，水泵叶轮材质为青铜",{"key":24,"text":125,"correct":22},"水泵最高处设置放水旋塞",{"key":28,"text":127,"correct":26},"泵体及外露的罩壳、箱体均喷涂大红漆",{"key":31,"text":129,"correct":26},"泵体上铸出了表示旋转方向的箭头",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},937556,"根据《消防给水及消火栓系统技术规范》（GB 50974）的规定，（ ）应对柴油机消防水泵的启动电池的电量进行检测，（ ）应检查储油箱的储油量，（ ）应手动启动柴油机消防水泵运行一次。",[134,136,138,140],{"key":20,"text":135,"correct":26},"每日，每日，每月",{"key":24,"text":137,"correct":26},"每周，每周，每月",{"key":28,"text":139,"correct":22},"每日，每周，每月",{"key":31,"text":141,"correct":26},"每日，每月，每季度",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},937557,"根据《消防给水及消火栓系统技术规范》（GB 50974）的规定，对消防给水系统供水设施进行维护管理，每（ ）应对消防水泵的出流量和压力进行一次试验。",[146,148,150,152],{"key":20,"text":147,"correct":26},"月",{"key":24,"text":149,"correct":22},"季度",{"key":28,"text":151,"correct":26},"半年",{"key":31,"text":153,"correct":26},"年",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},937558,"下列关于架空管道施工安装要求的说法，不正确的是（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":26},"架空管道外应刷红色油漆或涂红色环圈标志，并应注明管道名称和水流方向标识",{"key":24,"text":161,"correct":22},"架空管道外涂红色环圈标志时，红色环圈标志的宽度不应小于50mm",{"key":28,"text":163,"correct":26},"架空管道外涂红色环圈标志时，红色环圈标志的间隔不宜大于4m",{"key":31,"text":165,"correct":26},"架空管道外应刷红色油漆或涂红色环圈标志，若采用红色环圈标志，则一个独立的单元内环圈不宜少于2处",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":28,"analysis":33},937559,"某建筑高度为32m的综合楼，地上8层，地下1层，层高均为4m，每层建筑面积为1200㎡，建筑室内采用高位消防水箱稳压的临时高压消防给水系统，消防水泵房设置在地下一层，泵房内设有消防水泵、报警阀组及水泵控制柜，下列关于该建筑室内消防给水系统的说法，错误的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":26},"该建筑的自动喷水灭火系统室内和消火栓系统可以合用消防水泵",{"key":24,"text":173,"correct":26},"该建筑的水泵控制柜防护等级不应低于IP55",{"key":28,"text":175,"correct":22},"最不利点消火栓的静水压力不应低于0.07MPa",{"key":31,"text":177,"correct":26},"控制柜与基座应采用不小于?12mm的螺栓固定，每只柜不应少于4只螺栓",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":33},937560,"下列材质在实际工程中不适合做消防水箱的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":26},"不锈钢",{"key":24,"text":185,"correct":22},"玻璃钢",{"key":28,"text":187,"correct":26},"搪瓷钢板",{"key":31,"text":189,"correct":26},"钢筋混凝土",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},937561,"下列关于消防水箱检测验收的说法，正确的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"封闭水箱在试验压力下保持10min，压力不降、不渗不漏则封闭水箱的水压试验合格",{"key":24,"text":197,"correct":26},"敞口水箱装满水静置12h后观察，若不渗不漏，则敞口水箱的满水试验合格",{"key":28,"text":199,"correct":26},"封闭水箱在1.5倍的工作压力下保持30min，压力不降、不渗不漏则封闭水箱的水压试验合格",{"key":31,"text":201,"correct":26},"敞口水箱装满水静置48h后观察，若不渗不漏，则敞口水箱的满水试验合格",{"id":203,"libraryId":5,"type":204,"typeLabel":205,"stem":206,"options":207,"answer":219,"analysis":33},937562,2,"多选题","消防设施档案的保存期限不少于5年的有（ ）。",[208,210,212,214,216],{"key":20,"text":209,"correct":26},"《消防控制室值班记录表》",{"key":24,"text":211,"correct":22},"《建筑消防设施维护保养计划表》",{"key":28,"text":213,"correct":22},"《建筑消防设施故障维修记录表》",{"key":31,"text":215,"correct":26},"《建筑消防设施巡查记录表》",{"key":217,"text":218,"correct":22},"E","《建筑消防设施检测记录表》","BCE",{"id":221,"libraryId":5,"type":204,"typeLabel":205,"stem":222,"options":223,"answer":234,"analysis":33},937563,"消防水源的维护管理，每年对天然河、湖等地表水消防水源的（ ）等进行一次检测。",[224,226,228,230,232],{"key":20,"text":225,"correct":22},"常水位",{"key":24,"text":227,"correct":22},"枯水位",{"key":28,"text":229,"correct":22},"洪水位",{"key":31,"text":231,"correct":22},"枯水位流量或蓄水量",{"key":217,"text":233,"correct":26},"出水量","ABCD",{"id":236,"libraryId":5,"type":204,"typeLabel":205,"stem":237,"options":238,"answer":249,"analysis":33},937564,"消防水源的维护管理，每月对（ ）等消防水源设施的水位等进行一次检测；消防水池（箱）玻璃水位计两端的角阀在不进行水位观察时应关闭。",[239,241,243,245,247],{"key":20,"text":240,"correct":22},"消防水池",{"key":24,"text":242,"correct":22},"高位消防水池",{"key":28,"text":244,"correct":22},"高位消防水箱",{"key":31,"text":246,"correct":26},"天然河、湖",{"key":217,"text":248,"correct":26},"水井","ABC",{"id":251,"libraryId":5,"type":204,"typeLabel":205,"stem":252,"options":253,"answer":264,"analysis":33},937565,"下列关于供水设施的维护管理规定，每月应（ ）。",[254,256,258,260,262],{"key":20,"text":255,"correct":22},"手动启动消防水泵运转一次，并检查供电电源的情况",{"key":24,"text":257,"correct":22},"手动启动柴油机消防水泵运行一次",{"key":28,"text":259,"correct":22},"对气压水罐的压力和有效容积等进行一次检测",{"key":31,"text":261,"correct":26},"对稳压泵的停泵启泵压力和启泵次数等进行检查和记录运行情况",{"key":217,"text":263,"correct":22},"检测消防水泵自动巡检情况的记录","ABCE",{"id":266,"libraryId":5,"type":204,"typeLabel":205,"stem":267,"options":268,"answer":249,"analysis":33},937566,"下列关于消防水箱安装调试的说法中错误的是（ ）。",[269,271,272,274,276],{"key":20,"text":270,"correct":22},"消防水箱宜设置支墩，支墩的高度不宜小于800mm，以便于管道、附件的安装和检修",{"key":24,"text":201,"correct":22},{"key":28,"text":273,"correct":22},"封闭水箱在试验压力下保持30min，压力不降、不渗不漏则封闭水箱的水压试验合格",{"key":31,"text":275,"correct":26},"消防水箱的管道外壁与建筑本体结构墙面之间的净距为1米",{"key":217,"text":277,"correct":26},"消防水箱溢流管和泄放管应设置在排水地点附近，不得与排水管直接连接",{"id":279,"libraryId":5,"type":204,"typeLabel":205,"stem":280,"options":281,"answer":292,"analysis":33},937567,"下列关于供水设施设备维护管理的说法中正确的是（ ）。",[282,284,286,288,290],{"key":20,"text":283,"correct":22},"每季度进行流量压力试验：对消防水泵的出流量和压力进行一次试验",{"key":24,"text":285,"correct":26},"每月模拟消防水泵自动控制的条件自动启动消防水泵运转一次，并检查供电电源的情况",{"key":28,"text":287,"correct":26},"每周应手动启动消防水泵运转一次，并检查供电电源的情况",{"key":31,"text":289,"correct":22},"每日对稳压泵的停泵启泵压力和启泵次数等进行检查和记录运行情况",{"key":217,"text":291,"correct":26},"查看水泵接合器闸阀是否处于关闭状态；查看水泵接合器的标志是否还明显","AD",{"id":294,"libraryId":5,"type":204,"typeLabel":205,"stem":295,"options":296,"answer":234,"analysis":33},937568,"给水管网的主要作用是传输消防用水。管道系统由（ ）及相关设备共同组成，它们通过一定的方式连接起来，形成一套封闭的流体传输系统。",[297,299,301,303,305],{"key":20,"text":298,"correct":22},"管子",{"key":24,"text":300,"correct":22},"管件",{"key":28,"text":302,"correct":22},"配件",{"key":31,"text":304,"correct":22},"阀门",{"key":217,"text":306,"correct":26},"末端试水装置",{"id":308,"libraryId":5,"type":204,"typeLabel":205,"stem":309,"options":310,"answer":234,"analysis":33},937569,"目前消防给水管一般有（ ）等材料产品，管网的选择需要按照规范要求及实际情况来选取合适的材料。",[311,313,315,317,319],{"key":20,"text":312,"correct":22},"球墨铸铁管",{"key":24,"text":314,"correct":22},"钢丝骨架塑料复合管",{"key":28,"text":316,"correct":22},"热浸镀锌钢管（普通型、加厚型、无缝型）",{"key":31,"text":318,"correct":22},"加强防腐的钢管",{"key":217,"text":320,"correct":26},"冷镀锌钢管",{"id":322,"libraryId":5,"type":204,"typeLabel":205,"stem":323,"options":324,"answer":335,"analysis":33},937570,"给水管网的维护管理，每月应（ ）。",[325,327,329,331,333],{"key":20,"text":326,"correct":22},"对铅封、锁链进行一次检查，当有破坏或损坏时应及时修理更换",{"key":24,"text":328,"correct":22},"对电动阀和电磁阀的供电和启闭性能进行检测",{"key":28,"text":330,"correct":26},"对室外阀门井中进水管上的控制阀门进行一次检查，并应核实其处于全开启状态",{"key":31,"text":332,"correct":26},"对水源控制阀进行外观检查，并应保证系统处于无故障状态",{"key":217,"text":334,"correct":22},"对倒流防止器的压差进行检测","ABE",{"id":337,"libraryId":5,"type":204,"typeLabel":205,"stem":338,"options":339,"answer":350,"analysis":33},937571,"下列关于管网支吊架安装的说法中正确的是（ ）。",[340,342,344,346,348],{"key":20,"text":341,"correct":22},"当管道穿梁安装时，穿梁处宜作一个吊架",{"key":24,"text":343,"correct":26},"配水干管及配水管，配水支管的长度超过15m，每15m长度内应至少设1个防晃支架，当管径不大于DN50可不设",{"key":28,"text":345,"correct":22},"管径大于DN50管道拐弯、三通及四通位置处应设1个防晃支架",{"key":31,"text":347,"correct":26},"架空管道每段管道设置的防晃支架不少于2个；当管道改变方向时，增设防晃支架；立管在其始端和终端设防晃支架或采用管卡固定",{"key":217,"text":349,"correct":22},"配水管宜在中点设一个防晃支架，当管径小于DN50时可不设","ACE",{"id":352,"libraryId":5,"type":204,"typeLabel":205,"stem":353,"options":354,"answer":335,"analysis":33},937572,"稳压设备的检测验收要求为（ ）。",[355,357,359,361,363],{"key":20,"text":356,"correct":22},"稳压泵的型号性能等符合设计要求",{"key":24,"text":358,"correct":22},"稳压泵的控制符合设计要求，并有防止稳压泵频繁启动的技术措施",{"key":28,"text":360,"correct":26},"稳压泵在1h内的启停次数符合设计要求，不大于6次／h",{"key":31,"text":362,"correct":26},"火灾时稳压泵不需要工作，无需设置备用电源",{"key":217,"text":364,"correct":22},"稳压泵吸水管应设置明杆闸阀，稳压泵出水管应设置消声止回阀和明杆闸阀",{"id":366,"libraryId":5,"type":204,"typeLabel":205,"stem":367,"options":368,"answer":379,"analysis":33},937573,"对系统阀门的强度和严密性进行检查时，需要达到的要求有（ ）。",[369,371,373,375,377],{"key":20,"text":370,"correct":22},"强度和严密性试验要采用清水进行",{"key":24,"text":372,"correct":26},"严密性试验压力为公称压力的1.5倍",{"key":28,"text":374,"correct":26},"强度试验压力为公称压力的1.1倍",{"key":31,"text":376,"correct":22},"试验合格的阀门，要排尽内部积水，并吹干",{"key":217,"text":378,"correct":22},"试验压力在试验持续时间内要保持不变，且壳体填料和阀瓣密封面不能有渗漏","ADE",{"id":381,"libraryId":5,"type":204,"typeLabel":205,"stem":382,"options":383,"answer":234,"analysis":33},937574,"给水管网中，阀门的选用应根据（ ）来选择。",[384,386,388,390,392],{"key":20,"text":385,"correct":22},"介质的性质",{"key":24,"text":387,"correct":22},"最大工作压力",{"key":28,"text":389,"correct":22},"最高工作温度",{"key":31,"text":391,"correct":22},"介质的流量",{"key":217,"text":393,"correct":26},"介质的流动方向",{"id":395,"libraryId":5,"type":204,"typeLabel":205,"stem":396,"options":397,"answer":407,"analysis":33},937575,"下列关于消防给水系统架空管道支吊架安装要求的说法，不正确的有（ ）。",[398,399,401,403,405],{"key":20,"text":349,"correct":26},{"key":24,"text":400,"correct":22},"配水干管及配水管，配水支管的长度超过15m，每15m至少设1个防晃支架，当管径不大于DN50可不设",{"key":28,"text":402,"correct":26},"管径大于DN50的管道拐弯、三通及四通位置处应设1个防晃支架",{"key":31,"text":404,"correct":22},"架空管道每段管道设置的防晃支架不少于2个",{"key":217,"text":406,"correct":26},"当管道改变方向时应增设1个防晃支架","BD",{"id":409,"libraryId":5,"type":204,"typeLabel":205,"stem":410,"options":411,"answer":422,"analysis":33},937576,"某民用建筑的室内消防给水系统的管道采用镀锌钢管，消防水泵扬程为100m，水泵零流量时的压力为1.32MPa，下列关于该系统管网试压和冲洗的说法中，正确的有（ ）。",[412,414,416,418,420],{"key":20,"text":413,"correct":26},"当试压过程中出现渗漏时，应停止试压，放空介质后重新再试",{"key":24,"text":415,"correct":22},"水压强度试验的测试点应设在管网最低处",{"key":28,"text":417,"correct":22},"管网冲洗应在水压强度试验合格后分段进行",{"key":31,"text":419,"correct":22},"水压严密性试验应在水压强度试验和管网冲洗合格后进行",{"key":217,"text":421,"correct":26},"气压严密性试验的介质宜采用空气或氮气，试验压力应为0.28MPa，且稳压24h，压力降不应大于0.05MPa","BCD",{"id":424,"libraryId":5,"type":204,"typeLabel":205,"stem":425,"options":426,"answer":437,"analysis":33},937577,"下列关于供水设施维护管理的说法，不正确的有（ ）。",[427,429,431,433,435],{"key":20,"text":428,"correct":22},"每季度应对消防水泵、稳压泵的出流量和压力进行一次试验",{"key":24,"text":430,"correct":26},"每月应手动启动消防水泵运转一次，并检查供电电源的情况",{"key":28,"text":432,"correct":22},"每周模拟消防水泵自动控制的条件自动启动消防水泵运转一次，且应自动记录自动巡检情况，并应检测记录",{"key":31,"text":434,"correct":26},"每日对稳压泵的停泵启泵压力和启泵次数等进行检查并记录运行情况",{"key":217,"text":436,"correct":26},"每月应对气压水罐的压力和有效容积等进行一次检测","AC",{"id":439,"libraryId":5,"type":204,"typeLabel":205,"stem":440,"options":441,"answer":452,"analysis":33},937578,"下列关于消防给水系统减压阀安装要求的说法，正确的有（ ）。",[442,444,446,448,450],{"key":20,"text":443,"correct":22},"减压阀前后应安装压力表",{"key":24,"text":445,"correct":22},"减压阀水流方向应与供水管网水流方向一致",{"key":28,"text":447,"correct":26},"减压阀安装应在供水管网试压后、冲洗前进行",{"key":31,"text":449,"correct":22},"减压阀前应有过滤器",{"key":217,"text":451,"correct":22},"减压阀处应有压力试验用排水设施","ABDE",{"id":454,"libraryId":5,"type":204,"typeLabel":205,"stem":455,"options":456,"answer":249,"analysis":33},937579,"下列关于消防给水系统试压调试的做法，错误的有（ ）。",[457,459,461,463,465],{"key":20,"text":458,"correct":22},"在环境温度为4℃的情况下进行水压试验",{"key":24,"text":460,"correct":22},"水压严密性试验在水压强度试验和管网冲洗合格前进行",{"key":28,"text":462,"correct":22},"水压强度试验的测试点应设在系统管网的最高点",{"key":31,"text":464,"correct":26},"气压严密性试验的介质采用空气",{"key":217,"text":466,"correct":26},"消防给水系统的水源干管、进户管和室内埋地管道在回填前与系统同时进行水压强度试验和水压严密性试验",{"id":468,"libraryId":5,"type":204,"typeLabel":205,"stem":469,"options":470,"answer":481,"analysis":33},937580,"在消火栓系统中，消火栓箱按水带的安置方式可分为（ ）。",[471,473,475,477,479],{"key":20,"text":472,"correct":22},"卷盘式",{"key":24,"text":474,"correct":26},"明装式",{"key":28,"text":476,"correct":22},"挂置式",{"key":31,"text":478,"correct":22},"托架式",{"key":217,"text":480,"correct":22},"卷置式","ACDE",{"id":483,"libraryId":5,"type":204,"typeLabel":205,"stem":484,"options":485,"answer":437,"analysis":33},937581,"室外消火栓系统的消火栓井一般用（ ）砌筑。",[486,488,490,492,494],{"key":20,"text":487,"correct":22},"MU7.5红砖",{"key":24,"text":489,"correct":26},"MU8.5红砖",{"key":28,"text":491,"correct":22},"M7.5水泥砂浆",{"key":31,"text":493,"correct":26},"M8.5水泥砂浆",{"key":217,"text":495,"correct":26},"M6.5水泥砂浆",{"id":497,"libraryId":5,"type":204,"typeLabel":205,"stem":498,"options":499,"answer":292,"analysis":33},937582,"消火栓按公称压力可分为（ ）。",[500,502,504,506,508],{"key":20,"text":501,"correct":22},"1.0MPa承插式消火栓",{"key":24,"text":503,"correct":26},"1.6MPa承插式消火栓",{"key":28,"text":505,"correct":26},"1.0MPa法兰式消火栓",{"key":31,"text":507,"correct":22},"1.6MPa法兰式消火栓",{"key":217,"text":509,"correct":26},"2.0MPa承插式消火栓",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},937583,"进水口公称通径为150mm的消火栓，其吸水管出水口应选用规格为（ ）mm消防接口，水带出水口应选用规格为（ ）mm的消防接口。",[514,516,518,520],{"key":20,"text":515,"correct":26},"150,150",{"key":24,"text":517,"correct":22},"150,80",{"key":28,"text":519,"correct":26},"150,65",{"key":31,"text":521,"correct":26},"80,65",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":24,"analysis":33},937584,"水带长度小于水带长度规格（ ）m以上的，则可以判为该产品为不合格。",[526,528,530,532],{"key":20,"text":527,"correct":26},"0.5",{"key":24,"text":529,"correct":22},"1.0",{"key":28,"text":531,"correct":26},"1.5",{"key":31,"text":533,"correct":26},"2.0",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":31,"analysis":33},937585,"管道支、吊架的安装间距，材料选择，必须严格按照规定要求和施工图样的规定，接口缝距支吊连接缘不应小于（ ）mm，焊缝不得放在墙内。",[538,540,542,544],{"key":20,"text":539,"correct":26},"10",{"key":24,"text":541,"correct":26},"30",{"key":28,"text":543,"correct":26},"40",{"key":31,"text":545,"correct":22},"50",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":31,"analysis":33},937586,"常用8型水带的工作压力为0.8MPa，试验压力为1.2MPa，爆破压力不小于（ ）MPa。",[550,552,554,556],{"key":20,"text":551,"correct":26},"0.8",{"key":24,"text":553,"correct":26},"1.2",{"key":28,"text":555,"correct":26},"1.6",{"key":31,"text":557,"correct":22},"2.4",{"id":559,"libraryId":5,"type":204,"typeLabel":205,"stem":560,"options":561,"answer":572,"analysis":33},937587,"室内消火栓按出水口形式可分为（ ）。",[562,564,566,568,570],{"key":20,"text":563,"correct":26},"三口室内消火栓",{"key":24,"text":565,"correct":22},"双出口室内消火栓",{"key":28,"text":567,"correct":22},"单出口室内消火栓",{"key":31,"text":569,"correct":26},"单栓阀室内消火栓",{"key":217,"text":571,"correct":26},"45°出口型室内消火栓","BC",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":28,"analysis":33},937588,"消火栓系统是扑救、控制建筑物初期火灾的最为有效的灭火设施，是应用最为广泛、用量最大的消防灭火系统。该系统是以（ ）为介质，用于灭火、控火和冷却防护等功能的消防系统。",[577,579,581,583],{"key":20,"text":578,"correct":26},"干粉",{"key":24,"text":580,"correct":26},"二氧化碳",{"key":28,"text":582,"correct":22},"水",{"key":31,"text":584,"correct":26},"七氟丙烷",{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":24,"analysis":33},937589,"室外消火栓的检查主要包括产品标识、消防接口、排放余水装置和材料等。其中消防接口检查中，用小刀轻刮外螺纹固定接口和吸水管接口，目测外螺纹固定接口和吸水管接口的本体材料应由（ ）材料制造。",[589,591,593,595],{"key":20,"text":590,"correct":26},"铁质",{"key":24,"text":592,"correct":22},"铜质",{"key":28,"text":594,"correct":26},"铝质",{"key":31,"text":596,"correct":26},"钢质",{"id":598,"libraryId":5,"type":15,"typeLabel":16,"stem":599,"options":600,"answer":31,"analysis":33},937590,"消防水带的检查主要包括产品标识、织物层外观质量、水带长度和压力试验等，下列关于消防水带压力试验的说法中，不正确的是（ ）。",[601,603,605,607],{"key":20,"text":602,"correct":26},"截取1.2m长的水带，使用手动试压泵或电动试压泵平稳加压至试验压力",{"key":24,"text":604,"correct":26},"保压5min，检查是否有渗漏现象，有渗漏则不合格",{"key":28,"text":606,"correct":26},"在试验压力状态下，继续加压，升压至试样爆破",{"key":31,"text":608,"correct":22},"其爆破时压力不应小于水带工作压力的5倍",{"id":610,"libraryId":5,"type":15,"typeLabel":16,"stem":611,"options":612,"answer":28,"analysis":33},937591,"消防水带压力试验，要求截取1.2m长的水带，使用手动试压泵或电动试压泵平稳加压至试验压力，保压5min，检查是否有渗漏现象，有渗漏则不合格。常用8型水带的试验压力为1.2MPa，爆破压力不小于（ ）MPa。",[613,614,615,616],{"key":20,"text":551,"correct":26},{"key":24,"text":555,"correct":26},{"key":28,"text":557,"correct":22},{"key":31,"text":617,"correct":26},"3.2",{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":24,"analysis":33},937592,"消防水枪抗跌落性能检查中，要求将水枪以喷嘴垂直朝上，喷嘴垂直朝下（旋转开关处于关闭位置），以及水枪轴线处于水平（若有开关时，开关处于水枪轴线之下处并处于关闭位置）三个位置。从离地（2.0±0.02）m高处（从水枪的最低点算起）自由跌落到混凝土地面上。水枪在每个位置各跌落（ ）次，然后再检查水枪。如消防接口跌落后出现断裂或不能正常操纵使用的，则判该产品不合格。",[622,624,626,628],{"key":20,"text":623,"correct":26},"1",{"key":24,"text":625,"correct":22},"2",{"key":28,"text":627,"correct":26},"3",{"key":31,"text":629,"correct":26},"4",{"id":631,"libraryId":5,"type":15,"typeLabel":16,"stem":632,"options":633,"answer":20,"analysis":33},937593,"消防接口抗跌落性能要求，内扣式接口以扣爪垂直朝下的位置，将接口的最低点离地面（1.5±0.05）m高度，然后自由跌落到混凝土地面上。反复进行（ ）次后，检查接口是否断裂现象，并与相同口径的消防接口是否能正常操作。如消防接口跌落后出现断裂或不能正常操纵使用的，则判该产品为不合格。",[634,636,638,640],{"key":20,"text":635,"correct":22},"5",{"key":24,"text":637,"correct":26},"6",{"key":28,"text":639,"correct":26},"7",{"key":31,"text":641,"correct":26},"8",{"id":643,"libraryId":5,"type":15,"typeLabel":16,"stem":644,"options":645,"answer":24,"analysis":33},937594,"室内消火栓阀座及阀杆螺母材料性能应不低于（ ），阀杆本体材料性能应不低于（ ）。",[646,648,650,652],{"key":20,"text":647,"correct":26},"铜或不锈钢材料，铸造铜合金",{"key":24,"text":649,"correct":22},"黄铜，铅黄铜",{"key":28,"text":651,"correct":26},"黄铜，青铜",{"key":31,"text":653,"correct":26},"青铜，青铜或不锈钢",{"id":655,"libraryId":5,"type":15,"typeLabel":16,"stem":656,"options":657,"answer":24,"analysis":33},937595,"下列关于消防设备分类的说法中不正确的是（ ）",[658,660,662,664],{"key":20,"text":659,"correct":26},"室外消火栓按公称压力可分为1.0MPa（承插式）和1.6MPa（法兰式）两种",{"key":24,"text":661,"correct":22},"室内消火栓按阀数量可分为单出口室内消火栓和双出口室内消火栓",{"key":28,"text":663,"correct":26},"消防水枪按按其喷水方式可分为直流水枪，喷雾水枪和多用途水枪",{"key":31,"text":665,"correct":26},"消防水带按承受工作压力可分为0.8MPa、1.0MPa、1.3MPa、1.6MPa、2.0MPa、2.5MPa工作压力的消防水带",{"id":667,"libraryId":5,"type":15,"typeLabel":16,"stem":668,"options":669,"answer":20,"analysis":33},937596,"下列符合室内消火栓箱检查验收规定的是（ ）。",[670,672,674,676],{"key":20,"text":671,"correct":22},"栓口出水方向宜向下或与设置消火栓的墙面呈90°角，栓口不应安装在门轴侧",{"key":24,"text":673,"correct":26},"如设计未要求，栓口中心距地面应为1.1m，但每栋建筑物应一致，允许偏差±10mm",{"key":28,"text":675,"correct":26},"阀门的设置位置应便于操作使用，阀门的中心距箱侧面为100mm",{"key":31,"text":677,"correct":26},"消火栓箱体安装的垂直度允许偏差为±5mm",[679,682,685,688,691,694],{"id":15,"name":680,"category":7,"favorite":681},"领导干部任职前廉政法规知识测试题",92,{"id":683,"name":684,"category":7,"favorite":15},595,"建筑结构与设备",{"id":686,"name":687,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":689,"name":690,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":692,"name":693,"category":7,"favorite":8},534,"BIM工程师",{"id":695,"name":693,"category":7,"favorite":8},535]