[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-57":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":639},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,57,50,2974,[13,38,53,68,83,97,111,125,137,149,161,173,185,197,209,221,235,250,259,271,279,291,303,315,330,345,358,372,386,401,414,426,438,450,462,474,486,498,510,522,534,545,556,564,573,583,592,604,616,627],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},937497,2,"多选题","供水设施的维护管理规定包括（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","每季度应手动启动消防水泵运转一次，并检查供电电源的情况",false,{"key":24,"text":25,"correct":26},"B","每周应模拟消防水泵自动控制的条件自动启动消防水泵运转一次，且自动记录自动巡检情况，每月应检测记录",true,{"key":28,"text":29,"correct":26},"C","每日对稳压泵的停泵启泵压力和启泵次数等进行检查和记录运行情况",{"key":31,"text":32,"correct":26},"D","每日对柴油机消防水泵的启动电池的电量进行检测，每周检查储油箱的储油量，每月应手动启动柴油机消防水泵运行一次",{"key":34,"text":35,"correct":22},"E","每月应对消防水泵的出流量和压力进行一次试验","BCD","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},937498,"下列属于给水管网的试压和冲洗要求的是（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"冲洗前，对管道防晃支架、支吊架等进行检查，必要时应采取加固措施",{"key":24,"text":45,"correct":22},"管网排水坡度及辅助排水设施，符合设计要求",{"key":28,"text":47,"correct":26},"管网安装完毕后，要对其进行强度试验、冲洗和严密性试验",{"key":31,"text":49,"correct":26},"管网冲冼宜用水进行",{"key":34,"text":51,"correct":26},"强度试验和严密性试验宜用水进行","ACDE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},937499,"下列属于消防水池、消防水箱的检测验收要求的是（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"消防水池、消防水箱的施工和安装，应符合相关规定",{"key":24,"text":60,"correct":26},"观察检查水箱溢流管和泄放管应设置在排水地点附近但不得与排水管直接连接",{"key":28,"text":62,"correct":26},"对照图样，用测量工具检查水池容量是否符合要求",{"key":31,"text":64,"correct":26},"察看溢流管、泄水管的安装位置是否正确",{"key":34,"text":66,"correct":26},"测量取水口的高度和位置是否符合技术要求","BCDE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},937500,"消防水泵接合器的检查方法和技术要求包括（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"查看水泵接合器的外观是否有瑕疵，油漆是否完整，形状尺寸和安装尺寸与提供的安装图样是否相符",{"key":24,"text":75,"correct":26},"对照设计文件查看选择的水泵接合器的型号、名称是否准确、一致",{"key":28,"text":77,"correct":26},"水泵接合器的设置条件是否具备，其设置位置是否在室外便于消防车接近和使用的地点",{"key":31,"text":79,"correct":22},"检查水泵接合器的外形与室内消火栓是否雷同，以免混淆而延误灭火",{"key":34,"text":81,"correct":26},"检查水泵接合器组件（包括单向阀、安全阀、控制阀等）是否齐全","ABCE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":67,"analysis":37},937501,"在消防给水系统中，按照阀门在系统中的用途，可将阀门分为（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":22},"单向阀",{"key":24,"text":90,"correct":26},"截断阀",{"key":28,"text":92,"correct":26},"安全阀",{"key":31,"text":94,"correct":26},"减压阀",{"key":34,"text":96,"correct":26},"止回阀",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":82,"analysis":37},937502,"消防给水及消火栓系统管网施工时，应设防晃支架的有（ ）。",[101,103,105,107,109],{"key":20,"text":102,"correct":26},"管道管径为DN70的四通位置处",{"key":24,"text":104,"correct":26},"管径为DN100的管道拐弯处",{"key":28,"text":106,"correct":26},"管径为DN80的管道三通位置处",{"key":31,"text":108,"correct":22},"管径为DN40的配水管中点处",{"key":34,"text":110,"correct":26},"管径为DN80的配水管中点处",{"id":112,"libraryId":5,"type":113,"typeLabel":114,"stem":115,"options":116,"answer":28,"analysis":37},937503,1,"单选题","在阀门出口用压力表检查消防水泵停泵时，水锤消除后的压力不应超过水泵出口设计额定压力的（ ）倍。",[117,119,121,123],{"key":20,"text":118,"correct":22},"1",{"key":24,"text":120,"correct":22},"1.2",{"key":28,"text":122,"correct":26},"1.4",{"key":31,"text":124,"correct":22},"2",{"id":126,"libraryId":5,"type":113,"typeLabel":114,"stem":127,"options":128,"answer":28,"analysis":37},937504,"气压水罐安装时其四周要设检修通道，其宽度不宜小于（ ）m，消防气压给水设备顶部至楼板或梁底的距离不宜小于（ ）m。",[129,131,133,135],{"key":20,"text":130,"correct":22},"0.6.0.7",{"key":24,"text":132,"correct":22},"0.6,0.8",{"key":28,"text":134,"correct":26},"0.7,0.6",{"key":31,"text":136,"correct":22},"0.7,0.8",{"id":138,"libraryId":5,"type":113,"typeLabel":114,"stem":139,"options":140,"answer":28,"analysis":37},937505,"消防给水管网的冲洗顺序是（ ）。",[141,143,145,147],{"key":20,"text":142,"correct":22},"先室内，后室外",{"key":24,"text":144,"correct":22},"先地上，后地下",{"key":28,"text":146,"correct":26},"室内部分的冲洗应按配水干管、配水管、配水支管的顺序进行",{"key":31,"text":148,"correct":22},"室外部分的冲洗应按配水支管、配水管、配水干管的顺序进行",{"id":150,"libraryId":5,"type":113,"typeLabel":114,"stem":151,"options":152,"answer":20,"analysis":37},937506,"制作安装的管道支吊架的具体要求有（ ）。",[153,155,157,159],{"key":20,"text":154,"correct":26},"管道支、吊架材料除设计文件另有规定外，一般采用Q235普通碳素钢型材制作",{"key":24,"text":156,"correct":22},"管道支、吊架上面的孔洞采用电钻加工，也可用氧乙炔割孔",{"key":28,"text":158,"correct":22},"管道支、吊架成品后作保温处理，保温层完整、厚度均匀",{"key":31,"text":160,"correct":22},"管卡宜用镀银成型件",{"id":162,"libraryId":5,"type":113,"typeLabel":114,"stem":163,"options":164,"answer":20,"analysis":37},937507,"下列有关水泵机组的安装要求正确的是（ ）。",[165,167,169,171],{"key":20,"text":166,"correct":26},"水泵机组基础的平面尺寸，无隔振安装应较水泵机组底座四周各宽出：100~150mm",{"key":24,"text":168,"correct":22},"水泵机组基础的顶面标高，无隔振安装时应高出泵房地面不小于0.05m",{"key":28,"text":170,"correct":22},"泵房内管道管外底距地面的距离，当管径DN≤150mm时，不应小于0.25m",{"key":31,"text":172,"correct":22},"水泵吸水管水平段偏心大小头应采用管顶斜接",{"id":174,"libraryId":5,"type":113,"typeLabel":114,"stem":175,"options":176,"answer":20,"analysis":37},937508,"下列符合管网及阀门维护管理规定的是（ ）。",[177,179,181,183],{"key":20,"text":178,"correct":26},"每月对电动阀和电磁阀的供电和启闭性能进行检测",{"key":24,"text":180,"correct":22},"每周对水源控制阀进行外观检查，并应保证系统处于无故障状态",{"key":28,"text":182,"correct":22},"每年对系统所有的末端试水阀和报警阀的放水试验阀进行一次放水试验",{"key":31,"text":184,"correct":22},"每年对室外阀门井中进水管上的控制阀进行一次检查，并应核实其处于全开启状态",{"id":186,"libraryId":5,"type":113,"typeLabel":114,"stem":187,"options":188,"answer":20,"analysis":37},937509,"具有不破坏钢管镀锌层、施工快捷、密封性好、便于拆卸等优点的管道连接方式是（ ）。",[189,191,193,195],{"key":20,"text":190,"correct":26},"沟槽连接",{"key":24,"text":192,"correct":22},"承插连接",{"key":28,"text":194,"correct":22},"焊接连接",{"key":31,"text":196,"correct":22},"法兰连接",{"id":198,"libraryId":5,"type":113,"typeLabel":114,"stem":199,"options":200,"answer":24,"analysis":37},937510,"应急消防气压给水设备的稳压罐的公称直径不宜小于（ ）mm，出水口处应设有防止消防用水倒流进罐的措施。",[201,203,205,207],{"key":20,"text":202,"correct":22},"50",{"key":24,"text":204,"correct":26},"100",{"key":28,"text":206,"correct":22},"150",{"key":31,"text":208,"correct":22},"200",{"id":210,"libraryId":5,"type":113,"typeLabel":114,"stem":211,"options":212,"answer":24,"analysis":37},937511,"消防水池及消防水箱在施工安装时，其无管道侧面的净距不宜小于（ ）m。",[213,215,217,219],{"key":20,"text":214,"correct":22},"0.6",{"key":24,"text":216,"correct":26},"0.7",{"key":28,"text":218,"correct":22},"0.8",{"key":31,"text":220,"correct":22},"1.0",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":67,"analysis":37},937512,"水泵接合器的安装要求正确的是（ ）。",[225,227,229,231,233],{"key":20,"text":226,"correct":22},"水泵接合器接口距室外消火栓或消防水池的距离宜为10~40m",{"key":24,"text":228,"correct":26},"设计无要求时,墙壁水泵接合器安装高度距地面宜为0.7m",{"key":28,"text":230,"correct":26},"墙壁水泵接合器与墙面上的门、窗、孔、洞的净距离不应小于2.0m，且不应安装在玻璃幕墙下方",{"key":31,"text":232,"correct":26},"地下水泵接合器的安装，应使进水口与井盖底面的距离不大于0.4m，且不应小于井盖的半径",{"key":34,"text":234,"correct":26},"水泵接合器与给水系统之间不应设置除检修阀门以外其他的阀门",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":249,"analysis":37},937513,"使用沟槽连接件（卡箍）连接时其有关要求正确的是（ ）。",[239,241,243,245,247],{"key":20,"text":240,"correct":26},"有振动的场所应采用柔性接头",{"key":24,"text":242,"correct":22},"埋地管道宜采用刚性接头",{"key":28,"text":244,"correct":26},"埋地连接时螺栓和螺母应采用不锈钢件",{"key":31,"text":246,"correct":22},"机械四通开孔间距不应小于1m",{"key":34,"text":248,"correct":26},"配水干管（立管）与配水管（水平管）连接，应采用沟槽式管件，不应采用机械三通","ACE",{"id":251,"libraryId":5,"type":113,"typeLabel":114,"stem":252,"options":253,"answer":24,"analysis":37},937514,"消防水泵机组的额定功率小于或等于20kW时，其外轮廓面与墙面之间的最小间距为（ ）。",[254,256,257,258],{"key":20,"text":255,"correct":22},"0.4",{"key":24,"text":214,"correct":26},{"key":28,"text":220,"correct":22},{"key":31,"text":120,"correct":22},{"id":260,"libraryId":5,"type":113,"typeLabel":114,"stem":261,"options":262,"answer":28,"analysis":37},937515,"公称直径为50mm的管道支架，其设置的最大间距为（ ）m。",[263,265,267,269],{"key":20,"text":264,"correct":22},"4.0",{"key":24,"text":266,"correct":22},"4.5",{"key":28,"text":268,"correct":26},"5.0",{"key":31,"text":270,"correct":22},"6.0",{"id":272,"libraryId":5,"type":113,"typeLabel":114,"stem":273,"options":274,"answer":20,"analysis":37},937516,"水压试验时环境温度不宜低于（ ）℃，当低于（ ）℃时，水压试验应采取防冻措施。 A.5 B.10 C.15",[275,276,277,278],{"key":20,"text":20,"correct":26},{"key":24,"text":24,"correct":22},{"key":28,"text":28,"correct":22},{"key":31,"text":31,"correct":22},{"id":280,"libraryId":5,"type":113,"typeLabel":114,"stem":281,"options":282,"answer":20,"analysis":37},937517,"消防水源的维护管理，（ ）应检查消防水池、消防水箱等蓄水设施的结构材料是否完好，发现问题时及时处理。",[283,285,287,289],{"key":20,"text":284,"correct":26},"每年",{"key":24,"text":286,"correct":22},"每两年",{"key":28,"text":288,"correct":22},"每季度",{"key":31,"text":290,"correct":22},"每月",{"id":292,"libraryId":5,"type":113,"typeLabel":114,"stem":293,"options":294,"answer":20,"analysis":37},937518,"下列关于供水设施的维护管理规定，（ ）应模拟消防水泵自动控制的条件自动启动消防水泵运转一次，且自动记录自动巡检情况，（ ）应检测记录。",[295,297,299,301],{"key":20,"text":296,"correct":26},"每周，每月",{"key":24,"text":298,"correct":22},"每周，每周",{"key":28,"text":300,"correct":22},"每日，每周",{"key":31,"text":302,"correct":22},"每月，每季度",{"id":304,"libraryId":5,"type":113,"typeLabel":114,"stem":305,"options":306,"answer":20,"analysis":37},937519,"下列关于供水设施的维护管理规定，（ ）对柴油机消防水泵的启动电池的电量进行检测，（ ）检查储油箱的储油量，（ ）应手动启动柴油机消防水泵运行一次。",[307,309,311,313],{"key":20,"text":308,"correct":26},"每日，每周，每月",{"key":24,"text":310,"correct":22},"每周，每周，每月",{"key":28,"text":312,"correct":22},"每日，每月，每月",{"key":31,"text":314,"correct":22},"每日，每月，每季度",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":329,"analysis":37},937520,"消防水泵在安装前进行检查时，主要检查内容有（ ）。",[319,321,323,325,327],{"key":20,"text":320,"correct":26},"外观质量要求：是否有缺陷、涂层质量、形状尺寸和安装尺寸是否与安装图样相符、型号、名称、特性是否与设计说明一致",{"key":24,"text":322,"correct":26},"材料要求：外壳为球墨铸铁、叶轮为青铜或不锈钢",{"key":28,"text":324,"correct":26},"结构要求：易于现场维修和更换零件、不松动、有旋转方向的箭头、有放水旋塞",{"key":31,"text":326,"correct":26},"机械性能要求：型号与设计一致、流量、扬程、功率符合要求、轴封密封良好",{"key":34,"text":328,"correct":22},"水泵控制柜的要求：能否直接启动消防泵","ABCD",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":344,"analysis":37},937521,"下列关于消防水泵的检测验收要求中，正确的是（ ）。",[334,336,338,340,342],{"key":20,"text":335,"correct":26},"消防水泵运转应平稳，应无不良噪声的振动",{"key":24,"text":337,"correct":26},"对照图样，检查工作泵、备用泵、吸水管、出水管及出水管上泄压阀、水捶消除设施、止回阀、信号阀等的规格、型号、数量，应符合设计要求",{"key":28,"text":339,"correct":22},"吸水管、出水管上的控制阀应锁定在常闭位置，并有明显标记",{"key":31,"text":341,"correct":26},"分别开启系统中的每一个末端试水装置、试水阀和试验消火栓，水流指示器、压力开关、低压压力开关、高位消防水箱流量开关等信号的功能，均符合设计要求",{"key":34,"text":343,"correct":22},"在阀门出口用压力表检查消防水泵停泵时，水锤消除设施后的压力不应超过水泵出口设计额定压力的1.2倍","ABD",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":67,"analysis":37},937522,"消防水泵检测验收时，应启动消防泵进行测试，下列说法中正确的是（ ）。",[349,351,353,355,357],{"key":20,"text":350,"correct":22},"消防水泵启动控制按钮应置于手动启动挡",{"key":24,"text":352,"correct":26},"打开消防水泵出水管上试水阀，当采用主电源启动消防水泵时，消防水泵应启动正常",{"key":28,"text":354,"correct":26},"打开消防水泵出水管上试水阀，关掉主电源，主、备电源应能正常切换",{"key":31,"text":356,"correct":26},"消防水泵就地和远程启\u002F停功能应正常，并向消防控制室反馈状态信号",{"key":34,"text":335,"correct":26},{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":329,"analysis":37},937523,"给水管网包括室外管网和室内管网，包括（ ）等。",[362,364,366,368,370],{"key":20,"text":363,"correct":26},"室外消火栓给水管道",{"key":24,"text":365,"correct":26},"自动喷水灭火系统管道",{"key":28,"text":367,"correct":26},"室内消火栓给水管道",{"key":31,"text":369,"correct":26},"水喷雾灭火系统管道",{"key":34,"text":371,"correct":22},"消防设施的排水管道",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":344,"analysis":37},937524,"下列关于水泵接合器的维护管理规定，正确的是（ ）。",[376,378,380,382,384],{"key":20,"text":377,"correct":26},"查看水泵接合器周围有无放置构成操作障碍的物品",{"key":24,"text":379,"correct":26},"查看水泵接合器有无破损、变形、锈蚀及操作障碍，确保接口完好、无渗漏、闷盖齐全",{"key":28,"text":381,"correct":22},"查看闸阀是否处于关闭状态",{"key":31,"text":383,"correct":26},"查看水泵接合器的标志是否还明显",{"key":34,"text":385,"correct":22},"水泵接合器的安全阀及止回阀安装位置和方向应正确，阀门启闭应灵活",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":400,"analysis":37},937525,"管网支吊架按照支吊架的功能和型式可分为（ ）。",[390,392,394,396,398],{"key":20,"text":391,"correct":26},"固定支架",{"key":24,"text":393,"correct":26},"滑动支架",{"key":28,"text":395,"correct":26},"导向支架",{"key":31,"text":397,"correct":26},"弹簧支吊架",{"key":34,"text":399,"correct":26},"吊架","ABCDE",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":82,"analysis":37},937526,"消防增（稳）压设施由消防稳压泵和消防稳压罐组成。气压水罐上应设有（ ）。",[405,407,408,410,412],{"key":20,"text":406,"correct":26},"水位指示器",{"key":24,"text":92,"correct":26},{"key":28,"text":409,"correct":26},"压力开关或压力变送器",{"key":31,"text":411,"correct":22},"真空表",{"key":34,"text":413,"correct":26},"泄水管",{"id":415,"libraryId":5,"type":113,"typeLabel":114,"stem":416,"options":417,"answer":20,"analysis":37},937527,"下列关于消防水泵接合器安装要求的说法，正确的是（ ）。",[418,420,422,424],{"key":20,"text":419,"correct":26},"不应安装在玻璃幕墙下方",{"key":24,"text":421,"correct":22},"墙壁消防水泵接合器的安装应符合设计要求，设计无要求时，其安装高度距地面宜为1.1m",{"key":28,"text":423,"correct":22},"安装在墙壁上的水泵接合器与墙面上的门、窗、孔、洞的净距离不应大于2.0m",{"key":31,"text":425,"correct":22},"地下消防水泵接合器的安装，应使进水口与井盖底面的距离不大于0.4m，且不应小于井盖的直径",{"id":427,"libraryId":5,"type":113,"typeLabel":114,"stem":428,"options":429,"answer":24,"analysis":37},937528,"消防给水系统按范围分类，划分为（ ）。",[430,432,434,436],{"key":20,"text":431,"correct":22},"环状管网消防给水系统和枝状管网消防给水系统",{"key":24,"text":433,"correct":26},"独立消防给水系统和区域（集中）消防给水系统",{"key":28,"text":435,"correct":22},"室外消防给水系统和室内消防给水系统",{"key":31,"text":437,"correct":22},"消火栓灭火系统和自动喷水灭火系统",{"id":439,"libraryId":5,"type":113,"typeLabel":114,"stem":440,"options":441,"answer":28,"analysis":37},937529,"下列符合临时高压消防给水系统特点的是（ ）。",[442,444,446,448],{"key":20,"text":443,"correct":22},"能满足车载或手台移动消防水泵等取水所需的工作压力和流量",{"key":24,"text":445,"correct":22},"能始终保持水灭火系统所需的工作压力和流量",{"key":28,"text":447,"correct":26},"火灾时自动启动消防水泵，以满足水灭火系统所需的工作压力和流量",{"key":31,"text":449,"correct":22},"火灾时无须启动消防水泵直接加压，以满足水灭火系统所需的工作压力和流量",{"id":451,"libraryId":5,"type":113,"typeLabel":114,"stem":452,"options":453,"answer":31,"analysis":37},937530,"消防水泵控制柜的安装要求正确的是（ ）。",[454,456,458,460],{"key":20,"text":455,"correct":22},"控制柜的基座水平度误差不大于±1mm",{"key":24,"text":457,"correct":22},"控制柜的基座处应做防锈处理及防水措施",{"key":28,"text":459,"correct":22},"控制柜与基座采用不小于φ10mm的螺栓固定，每个控制柜不应少于4只螺栓",{"key":31,"text":461,"correct":26},"做控制柜的上下进出线口时，不应破坏控制柜的防护等级",{"id":463,"libraryId":5,"type":113,"typeLabel":114,"stem":464,"options":465,"answer":24,"analysis":37},937531,"应设置固定支架或防晃支架的地方有（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":22},"管径小于DN50的配水管中点",{"key":24,"text":469,"correct":26},"配水干管及配水管，配水支管的长度超过15m，每15m长度内，管径不大于DN40mm的除外",{"key":28,"text":471,"correct":22},"管径大于DN40的管道拐弯、三通及四通位置处",{"key":31,"text":473,"correct":22},"立管的中间部位",{"id":475,"libraryId":5,"type":113,"typeLabel":114,"stem":476,"options":477,"answer":28,"analysis":37},937532,"下列符合供水设施维护管理规定的是（ ）。",[478,480,482,484],{"key":20,"text":479,"correct":22},"每月应手动启动消防水泵运转两次，并检查供电电源的情况",{"key":24,"text":481,"correct":22},"每周对稳压泵的停泵启泵压力和启泵次数等进行检查和记录运行情况",{"key":28,"text":483,"correct":26},"每季度应对消防水泵的出流量和压力进行一次试验",{"key":31,"text":485,"correct":22},"每日对气压水罐的压力和有效容积等进行一次检测",{"id":487,"libraryId":5,"type":113,"typeLabel":114,"stem":488,"options":489,"answer":31,"analysis":37},937533,"消防供水设施（设备）主要包括消防水泵、消防增（稳）压设施、水泵接合器等，下列对于消防水泵外观质量、材料、结构和机械性能等说法中不正确的是（ ）。",[490,492,494,496],{"key":20,"text":491,"correct":22},"所有铸件外表面不应有明显的结疤、气泡、砂眼等缺陷",{"key":24,"text":493,"correct":22},"水泵外壳宜为球墨铸铁；水泵叶轮宜为青铜或不锈钢",{"key":28,"text":495,"correct":22},"消防泵体上应铸出表示旋转方向的箭头",{"key":31,"text":497,"correct":26},"泵应设置放水旋塞，放水旋塞应处于泵的最高位置以便排尽泵内余水",{"id":499,"libraryId":5,"type":113,"typeLabel":114,"stem":500,"options":501,"answer":28,"analysis":37},937534,"管网支吊架是各种不同形式的支架和吊架的总称。按照支吊架的功能和形式可分为：固定支架、滑动支架、导向支架、弹簧支吊架、吊架等。下列有关管网支吊架说法中，不正确的是（ ）。",[502,504,506,508],{"key":20,"text":503,"correct":22},"管道支、吊架材料一般采用Q235普通碳素钢型材制作",{"key":24,"text":505,"correct":22},"管道支、吊架的切边均匀无毛刺，焊缝均匀完整、外观成形良好、没有欠焊、漏焊、裂纹和绞内等缺陷",{"key":28,"text":507,"correct":26},"管道支、吊架上面的孔洞采用氧乙炔割孔",{"key":31,"text":509,"correct":22},"管道支、吊架上管卡、吊杆等部件的螺纹光洁整齐，无断丝和毛刺等缺陷",{"id":511,"libraryId":5,"type":113,"typeLabel":114,"stem":512,"options":513,"answer":28,"analysis":37},937535,"消防水箱采用钢筋混凝土时，在消防水箱的内部应贴白瓷砖或喷涂瓷釉涂料。采用其他材料时，消防水箱宜设置支墩，支墩的高度不宜小于()mm，以便于管道、附件的安装和检修。",[514,516,518,520],{"key":20,"text":515,"correct":22},"400",{"key":24,"text":517,"correct":22},"500",{"key":28,"text":519,"correct":26},"600",{"key":31,"text":521,"correct":22},"700",{"id":523,"libraryId":5,"type":113,"typeLabel":114,"stem":524,"options":525,"answer":20,"analysis":37},937536,"消防水箱的检测验收中，对于敞口水箱装满水静置24h后观察，若不渗不漏，则敞口水箱的满水试验合格；而封闭水箱在试验压力下保持（ ）min，压力不降、不渗不漏则封闭水箱的水压试验合格。",[526,528,530,532],{"key":20,"text":527,"correct":26},"10",{"key":24,"text":529,"correct":22},"20",{"key":28,"text":531,"correct":22},"30",{"key":31,"text":533,"correct":22},"40",{"id":535,"libraryId":5,"type":113,"typeLabel":114,"stem":536,"options":537,"answer":28,"analysis":37},937537,"水泵接合器是供消防车向消防给水管网输送消防用水的预留接口。在火灾情况下，当建筑物内消防水泵发生故障或室内消防用水不足时，消防车从室外取水通过水泵接合器将水送到室内消防给水管网，供灭火使用。水泵接合器的检测验收中不符合验收要求的是（ ）。",[538,540,541,543],{"key":20,"text":539,"correct":22},"消火栓水泵接合器与消防通道之间不应设有妨碍消防车加压供水的障碍物",{"key":24,"text":385,"correct":22},{"key":28,"text":542,"correct":26},"水泵接合器无须设置明显的耐久性指示标志",{"key":31,"text":544,"correct":22},"消防水泵接合器应采用消防车车载消防水泵进行充水试验，且供水最不利点的压力、流量应符合设计要求",{"id":546,"libraryId":5,"type":113,"typeLabel":114,"stem":547,"options":548,"answer":20,"analysis":37},937538,"消防给水管穿过建筑物承重墙或基础时，应预留洞口，洞口高度应保证管顶上部净空不小于建筑物的沉降量，不宜小于（ ）m，并应填充不透水的弹性材料。",[549,551,553,555],{"key":20,"text":550,"correct":26},"0.1",{"key":24,"text":552,"correct":22},"0.2",{"key":28,"text":554,"correct":22},"0.3",{"key":31,"text":255,"correct":22},{"id":557,"libraryId":5,"type":113,"typeLabel":114,"stem":558,"options":559,"answer":24,"analysis":37},937539,"消防给水架空管道外刷红色油漆或涂红色环圈标志，并注明管道名称和水流方向标识。红色环圈标志，宽度不应小于（ ）mm，间隔不宜大于4m，在一个独立的单元内环圈不宜少于2处。",[560,561,562,563],{"key":20,"text":527,"correct":22},{"key":24,"text":529,"correct":26},{"key":28,"text":531,"correct":22},{"key":31,"text":533,"correct":22},{"id":565,"libraryId":5,"type":113,"typeLabel":114,"stem":566,"options":567,"answer":28,"analysis":37},937540,"消防给水管网冲洗管道直径大于DN（ ）mm时，应对其死角和底部进行敲打，但不得损伤管道。",[568,569,571,572],{"key":20,"text":202,"correct":22},{"key":24,"text":570,"correct":22},"75",{"key":28,"text":204,"correct":26},{"key":31,"text":206,"correct":22},{"id":574,"libraryId":5,"type":113,"typeLabel":114,"stem":575,"options":576,"answer":28,"analysis":37},937541,"一消防给水系统设计工作压力1.2MPa，该系统管网进行水压强度试验压力为（ ）MPa。",[577,578,579,581],{"key":20,"text":120,"correct":22},{"key":24,"text":122,"correct":22},{"key":28,"text":580,"correct":26},"1.6",{"key":31,"text":582,"correct":22},"1.8",{"id":584,"libraryId":5,"type":113,"typeLabel":114,"stem":585,"options":586,"answer":24,"analysis":37},937542,"消防给水系统的维护管理是确保系统正常完好、有效使用的基本保障。维护管理人员经过消防专业培训后应熟悉消防给水系统的相关原理、性能和操作维护方法。其中对供水设施的维护管理规定，（ ）应对消防水泵的出流量和压力进行一次试验。",[587,588,589,591],{"key":20,"text":290,"correct":22},{"key":24,"text":288,"correct":26},{"key":28,"text":590,"correct":22},"每半年",{"key":31,"text":284,"correct":22},{"id":593,"libraryId":5,"type":113,"typeLabel":114,"stem":594,"options":595,"answer":24,"analysis":37},937543,"封闭消防水箱的水压试验时，水箱在试验压力下保持（ ），压力不降、不渗漏则封闭水箱的水压试验合格。",[596,598,600,602],{"key":20,"text":597,"correct":22},"5min",{"key":24,"text":599,"correct":26},"10min",{"key":28,"text":601,"correct":22},"20min",{"key":31,"text":603,"correct":22},"30min",{"id":605,"libraryId":5,"type":113,"typeLabel":114,"stem":606,"options":607,"answer":31,"analysis":37},937544,"在检测验收时，对照设计资料检查江、河、湖、海、水库和水塘等天然水源的水量、水质是否符合设计要求，应验证其（ ）的流量符合设计要求；地下水井的常水位、出水量等应符合设计要求。",[608,610,612,614],{"key":20,"text":609,"correct":22},"水位",{"key":24,"text":611,"correct":22},"常水位",{"key":28,"text":613,"correct":22},"枯水位和洪水位",{"key":31,"text":615,"correct":26},"枯水位、洪水位和常水位",{"id":617,"libraryId":5,"type":113,"typeLabel":114,"stem":618,"options":619,"answer":24,"analysis":37},937545,"消防水泵的外观质量要求说法错误的是（ ）。",[620,621,623,625],{"key":20,"text":491,"correct":22},{"key":24,"text":622,"correct":26},"泵体以及各种外露的罩壳、箱体均不应喷涂油漆",{"key":28,"text":624,"correct":22},"消防水泵的形状尺寸和安装尺寸与提供的安装图纸应相符",{"key":31,"text":626,"correct":22},"查看铭牌上标注的泵的型号、名称、特性应与设计说明一致",{"id":628,"libraryId":5,"type":113,"typeLabel":114,"stem":629,"options":630,"answer":28,"analysis":37},937546,"下列关于管网支吊架的安装，正确的是（ ）。",[631,633,635,637],{"key":20,"text":632,"correct":22},"设计的吊架在管道的每一支撑点处应能承受十倍于充满水的管重，且管道系统支撑点应支撑整个消防给水系统",{"key":24,"text":634,"correct":22},"管道支架的支撑点宜设在建筑物的结构上，其结构在管道悬吊点应能承受充满水管道质量另加至少100kg的阀门、法兰和接头等附加荷载",{"key":28,"text":636,"correct":26},"大口径的阀门和部件不应该由管道来承重，应该设置支吊架承重",{"key":31,"text":638,"correct":22},"当管道穿梁安装时，穿梁处管道作用于梁上，可作为一个吊架，不需要单独设置吊架",[640,643,646,649,652,655],{"id":113,"name":641,"category":7,"favorite":642},"领导干部任职前廉政法规知识测试题",92,{"id":644,"name":645,"category":7,"favorite":113},595,"建筑结构与设备",{"id":647,"name":648,"category":7,"favorite":113},715,"招标采购专业知识与法律法规",{"id":650,"name":651,"category":7,"favorite":113},848,"市政方向-通用基础",{"id":653,"name":654,"category":7,"favorite":8},534,"BIM工程师",{"id":656,"name":654,"category":7,"favorite":8},535]