[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-56":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":639},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,56,50,2974,[13,34,46,58,70,82,94,106,118,136,150,164,179,194,209,221,233,245,257,269,281,293,305,317,329,341,349,361,371,383,395,407,419,431,443,455,467,479,488,496,508,520,532,544,556,568,580,595,610,624],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},937447,1,"单选题","现场检查项目中对不合格的设备及其组件、材料进行返修或者更换后，进行复验。复验时，对有抽验比例有要求的，应（ ）抽样检查。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","反复",false,{"key":24,"text":25,"correct":26},"B","加倍",true,{"key":28,"text":29,"correct":22},"C","单独",{"key":31,"text":32,"correct":22},"D","按原计划","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},937448,"消防设施维护管理不包括（ ）工作。",[38,40,42,44],{"key":20,"text":39,"correct":22},"值班",{"key":24,"text":41,"correct":22},"巡查",{"key":28,"text":43,"correct":22},"检测",{"key":31,"text":45,"correct":26},"安装",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},937449,"2013年某消防单位对某一个重要的化工生产单位进行了消防设施现场检查，这次消防设施现场检查不包括()。",[50,52,54,56],{"key":20,"text":51,"correct":22},"产品合法性检查",{"key":24,"text":53,"correct":22},"产品一致性检查",{"key":28,"text":55,"correct":22},"产品质量检查",{"key":31,"text":57,"correct":26},"消防设施技术检测",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},937450,"某大型综合楼二层为室内商业街，由于某商铺用火不慎引发店面火灾，商铺业主及时报警。该综合楼消防控制室值班人员在接到报警后，采取应急程序处置火灾的各项做法中，不正确的是（ ）",[62,64,66,68],{"key":20,"text":63,"correct":26},"接到火灾警报后，值班人员首先赶往火灾现场扑灭火灾",{"key":24,"text":65,"correct":22},"火灾确认后，值班人员立即确认火灾报警联动控制开关处于自动控制状态，同时拨打“119\"报警电话准确报警",{"key":28,"text":67,"correct":22},"报警时说明着火单位地点、起火部位、着火物种类、火势大小、报警人姓名和联系电话等",{"key":31,"text":69,"correct":22},"值班人员立即启动单位应急疏散和初期火灾扑救灭火预案，同时报告单位消防安全负责人",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},937451,"消防部门对新建综合楼进行消防验收检查，发现该楼消防设施的设备、组件以及材料存在产品质量问题和施工安装质量问题，不能满足相关国家工程建设消防技术标准的，下列处理错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"更换相关消防设施的设备、组件及材料的，进行施工返工处理，重新组织产品现场检查、技术检测或者竣工验收",{"key":24,"text":77,"correct":22},"返修处理，能够满足相关标准规定和使用要求的，按照经批准的处理技术方案和协议文件，重新组织现场检查、技术检测或者竣工验收",{"key":28,"text":79,"correct":22},"返修或者更换相关消防设施的设备、组件及材料的，经重新组织现场检查、技术检测、竣工验收，仍然不符合要求的，判定为现场检查、技术检测、竣工验收不合格",{"key":31,"text":81,"correct":26},"未经现场检查合格的消防设施的设备、组件及材料，但具有强制认证证书的可以用于施工安装",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},937452,"下列关于消防产品及施工安装质量问题处理的做法，不正确的是()。",[86,88,90,92],{"key":20,"text":87,"correct":22},"更换相关消防设施的设备、组件以及材料，进行施工返工处理，重新组织产品现场检查、技术检测或者竣工验收",{"key":24,"text":89,"correct":26},"返修处理后，能够满足相关标准规定和使用要求的，可直接判定为竣工验收合格",{"key":28,"text":91,"correct":22},"对于需要更换相关消防设施的设备、组件以及材料的，经重新组织现场检查、技术检测、竣工验收，仍然不符合要求的，判定为现场检查、技术检测、竣工验收不合格",{"key":31,"text":93,"correct":22},"未经现场检查合格的消防设施的设备、组件以及材料，不得用于施工安装",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},937453,"下列不能作为消防设施施工安装依据的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"型式检验报告",{"key":24,"text":101,"correct":22},"经法定机构备案的消防设计文件",{"key":28,"text":103,"correct":22},"国家工程建设消防技术标准",{"key":31,"text":105,"correct":22},"经法定机构批准的消防设计文件",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},937454,"下列关于消防控制室值班要求的说法，错误的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"实行每日24h值班制度，值班人员应通过消防行业特有工种职业技能鉴定，持有初级技能（含）以上等级的职业资格证书",{"key":24,"text":113,"correct":26},"每班工作时间应不大于12h，每班人员应不少于2人",{"key":28,"text":115,"correct":22},"值班期间每2h记录一次消防控制室内消防设备的运行情况，及时记录消防控制室内消防设备的火警或故障情况",{"key":31,"text":117,"correct":22},"正常工作状态下，不应将自动喷水灭火系统、防烟排烟系统和联动控制的防火卷帘等防火分隔设施设置在手动控制状态",{"id":119,"libraryId":5,"type":120,"typeLabel":121,"stem":122,"options":123,"answer":135,"analysis":33},937455,2,"多选题","为确保消防控制室实现接受火灾报警、处置火灾信息、指挥火灾扑救、引导人员安全疏散等消防安全目标，消防控制室配备的监控设备要能够准确、规范的实施消防监控与管理等各项功能。下列关于消防控制室配备的消防设备监控功能描述中，正确的是（ ）。",[124,126,128,130,132],{"key":20,"text":125,"correct":26},"消防控制室设置的消防设备能够监控并显示消防设施运行状态信息，并能够向城市消防远程监控中心传输相应信息",{"key":24,"text":127,"correct":26},"根据建筑（单位）规模及其火灾危险性特点，消防控制室内需要保存必要的文字、电子资料，存储相关的消防安全管理信息，并能够及时向监控中心传输消防安全管理信息",{"key":28,"text":129,"correct":26},"大型建筑群要根据其不同建筑功能需求、火灾危险性特点和消防安全监控需要，设置两个及两个以上的消防控制室，并确定主消防控制室、分消防控制室",{"key":31,"text":131,"correct":26},"主消防控制室的消防设备能够对系统内共用消防设备进行控制，显示其状态信息，并能够显示各个分消防控制室内消防设备的状态信息，具备对分消防控制室内消防设备及其所控制的消防系统、设备的控制功能",{"key":133,"text":134,"correct":22},"E","各个分消防控制室的消防设备之间，可以互相传输、显示状态信息，按照重要性等方面不同可以互相控制消防设备","ABCD",{"id":137,"libraryId":5,"type":120,"typeLabel":121,"stem":138,"options":139,"answer":149,"analysis":33},937456,"消防设施施工安装以经法定机构批准或者备案的（ ）为依据。",[140,142,144,145,147],{"key":20,"text":141,"correct":22},"消防设备联动逻辑说明",{"key":24,"text":143,"correct":26},"消防设计文件",{"key":28,"text":103,"correct":26},{"key":31,"text":146,"correct":22},"产品质量检验文件",{"key":133,"text":148,"correct":22},"系统布线图","BC",{"id":151,"libraryId":5,"type":120,"typeLabel":121,"stem":152,"options":153,"answer":135,"analysis":33},937457,"消防设施竣工验收时，施工单位需要提交的资料有（ ）。",[154,156,158,160,162],{"key":20,"text":155,"correct":26},"竣工验收申请报告",{"key":24,"text":157,"correct":26},"隐蔽工程检查验收记录以及灭火系统阀门、其他组件的强度和严密性试验记录、管道试压和冲洗记录",{"key":28,"text":159,"correct":26},"设备、组件、材料符合市场准入制度的有效证明文件、出厂质量合格证明文件以及现场检查（验）报告",{"key":31,"text":161,"correct":26},"施工现场质量管理检查记录、施工过程质量管理检查记录以及工程质量事故处理报告",{"key":133,"text":163,"correct":22},"施工单位签署的工程质量保修书",{"id":165,"libraryId":5,"type":120,"typeLabel":121,"stem":166,"options":167,"answer":178,"analysis":33},937458,"消防设施档案的保存期限为5年的有（ ）。",[168,170,172,174,176],{"key":20,"text":169,"correct":22},"《消防控制室值班记录表》",{"key":24,"text":171,"correct":26},"《建筑消防设施维护保养计划表》",{"key":28,"text":173,"correct":26},"《建筑消防设施故障维修记录表》",{"key":31,"text":175,"correct":22},"《建筑消防设施巡查记录表》",{"key":133,"text":177,"correct":26},"《建筑消防设施检测记录表》","BCE",{"id":180,"libraryId":5,"type":120,"typeLabel":121,"stem":181,"options":182,"answer":193,"analysis":33},937459,"在消防给水系统中，稳压泵在1h内的启停次数符合设计要求的是（ ）。",[183,185,187,189,191],{"key":20,"text":184,"correct":26},"13次\u002Fh",{"key":24,"text":186,"correct":26},"14次\u002Fh",{"key":28,"text":188,"correct":26},"15次\u002Fh",{"key":31,"text":190,"correct":22},"16次\u002Fh",{"key":133,"text":192,"correct":22},"17次\u002Fh","ABC",{"id":195,"libraryId":5,"type":120,"typeLabel":121,"stem":196,"options":197,"answer":208,"analysis":33},937460,"消防给水系统气压严密性试验的介质宜采用（ ）。",[198,200,202,204,206],{"key":20,"text":199,"correct":22},"氢气",{"key":24,"text":201,"correct":22},"氧气",{"key":28,"text":203,"correct":22},"氯气",{"key":31,"text":205,"correct":26},"空气",{"key":133,"text":207,"correct":26},"氮气","DE",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":24,"analysis":33},937461,"能始终保持水灭火系统所需的工作压力和流量，火灾时无须启动消防水泵直接加压的消防给水系统是（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":22},"低压消防给水系统",{"key":24,"text":216,"correct":26},"高压消防给水系统",{"key":28,"text":218,"correct":22},"稳高压消防给水系统",{"key":31,"text":220,"correct":22},"临时高压消防给水系统",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":24,"analysis":33},937462,"可用作消防水源的有市政给水、消防水池、天然水源、消防水箱和其他几类水源。其中下列市政给水管网作为消防水源的条件不正确的是（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":22},"市政给水管网可以连续供水",{"key":24,"text":228,"correct":26},"市政给水管网一般布置成环状管网，在条件困难时可以布置成放射状",{"key":28,"text":230,"correct":22},"市政给水厂至少有两条输水干管向市政给水管网输水",{"key":31,"text":232,"correct":22},"有不同市政给水干管上不少于两条引入管向消防给水系统供水",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":20,"analysis":33},937463,"消防增（稳）压设施由消防稳压泵和消防稳压罐组成。其中气压罐的出水口公称直径按流量计算确定，应急消防气压给水设备其公称直径不宜小于（ ）mm，出水口处应设有防止消防用水倒流进罐的措施。",[237,239,241,243],{"key":20,"text":238,"correct":26},"100",{"key":24,"text":240,"correct":22},"200",{"key":28,"text":242,"correct":22},"300",{"key":31,"text":244,"correct":22},"400",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":28,"analysis":33},937464,"在施工安装时，消防水池及消防水箱的外壁与建筑本体结构墙面或其他池壁之间的净距，要满足施工、装配和检修的需要。无管道的侧面，净距不宜小于（ ）m；有管道的侧面，净距不宜小于1.0m，且管道外壁与建筑本体墙面之间的通道宽度不宜小于0.6m；设有人孔的池顶，顶板面与上面建筑本体板底的净空不应小于0.8m。",[249,251,253,255],{"key":20,"text":250,"correct":22},"0.5",{"key":24,"text":252,"correct":22},"0.6",{"key":28,"text":254,"correct":26},"0.7",{"key":31,"text":256,"correct":22},"0.8",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":31,"analysis":33},937465,"适合做消防水箱的材料有许多种，最常见的材料有碳素钢、不锈钢、钢筋混凝土、玻璃钢、搪瓷钢板等材料，它们均具有一定的优缺点。其中（ ）水箱受紫外线照射时强度有变化、橡胶垫片易老化、漏水，故在消防水箱中不推荐使用。",[261,263,265,267],{"key":20,"text":262,"correct":22},"碳素钢",{"key":24,"text":264,"correct":22},"不锈钢",{"key":28,"text":266,"correct":22},"钢筋混凝土",{"key":31,"text":268,"correct":26},"玻璃钢",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":20,"analysis":33},937466,"消防水池和消防水箱施工和安装中，要求消防水池和消防水箱出水管或水泵吸水管要满足（ ）的技术要求。",[273,275,277,279],{"key":20,"text":274,"correct":26},"最低有效水位出水不掺气",{"key":24,"text":276,"correct":22},"最低有效水位出水掺气",{"key":28,"text":278,"correct":22},"最高有效水位出水不掺气",{"key":31,"text":280,"correct":22},"最高有效水位出水掺气",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":28,"analysis":33},937467,"水泵安装得好坏，对水泵的运行和寿命有重要影响。水泵安装有整体安装和分体安装两种方式。下列关于水泵安装操作中不正确的是（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":22},"分体水泵安装时，应先安装水泵再安装电动机",{"key":24,"text":288,"correct":22},"整体安装时，首先清除泵座底面上的油腻和污垢，将水泵吊装放置在水泵基础上",{"key":28,"text":290,"correct":26},"泵房主要人行通道宽度不宜小于2.2m，电气控制柜前通道宽度不宜小于2.5m",{"key":31,"text":292,"correct":22},"水泵吸水管水平段偏心大小头应采用管顶平接，避免产生气囊和漏气现象",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":31,"analysis":33},937468,"消防水泵的检测验收要求，在阀门出口用压力表检查消防水泵停泵时，水锤消除设施后的压力不应超过水泵出口设计额定压力的（ ）倍。",[297,299,301,303],{"key":20,"text":298,"correct":22},"1.1",{"key":24,"text":300,"correct":22},"1.2",{"key":28,"text":302,"correct":22},"1.3",{"key":31,"text":304,"correct":26},"1.4",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":24,"analysis":33},937469,"稳压泵验收要求，稳压泵在1h内的启停次数符合设计要求，不大于（ ）次／h。",[309,311,313,315],{"key":20,"text":310,"correct":22},"10",{"key":24,"text":312,"correct":26},"15",{"key":28,"text":314,"correct":22},"20",{"key":31,"text":316,"correct":22},"25",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":24,"analysis":33},937470,"消防管道工程常用的连接方式有螺纹连接、焊接连接、法兰连接、承插连接、沟槽连接等形式。（ ）的主要优点是接口牢固耐久，不易渗漏，接头强度和严密性高，使用后不需要经常管理。",[321,323,325,327],{"key":20,"text":322,"correct":22},"螺纹连接",{"key":24,"text":324,"correct":26},"焊接连接",{"key":28,"text":326,"correct":22},"法兰连接",{"key":31,"text":328,"correct":22},"承插连接",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":28,"analysis":33},937471,"消防给水管穿过墙体或楼板时要加设套管，套管长度不小于墙体厚度，或高出楼面或地面（ ）mm；套管与管道的间隙应采用不燃材料填塞，管道的接口不应位于套管内。",[333,335,337,339],{"key":20,"text":334,"correct":22},"30",{"key":24,"text":336,"correct":22},"40",{"key":28,"text":338,"correct":26},"50",{"key":31,"text":340,"correct":22},"60",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":24,"analysis":33},937472,"给水管网架空管道应设置固定支架或防晃支架。配水干管及配水管，配水支管每（ ）m长度内应至少设1个防晃支架。",[345,346,347,348],{"key":20,"text":310,"correct":22},{"key":24,"text":312,"correct":26},{"key":28,"text":314,"correct":22},{"key":31,"text":316,"correct":22},{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":28,"analysis":33},937473,"消防给水管网施工完成后，要进行试压和冲洗。系统试压前选用试压用的压力表不少于2只，精度不低于1.5级，量程为试验压力值的（ ）倍。",[353,355,357,359],{"key":20,"text":354,"correct":22},"0.5～1.0",{"key":24,"text":356,"correct":22},"1.0～1.5",{"key":28,"text":358,"correct":26},"1.5～2.0",{"key":31,"text":360,"correct":22},"2.0～2.5",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},937474,"消防给水管网进行水压强度试验，当系统设计工作压力等于或小于1.0MPa时，水压强度试验压力应为设计工作压力的（ ）倍，并不应低于1.4MPa。",[365,366,367,369],{"key":20,"text":298,"correct":22},{"key":24,"text":302,"correct":22},{"key":28,"text":368,"correct":26},"1.5",{"key":31,"text":370,"correct":22},"1.7",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":28,"analysis":33},937475,"消防给水系统水压强度试验的测试点应设在系统管网的（ ）。对管网注水时，应将管网内的空气排净，并缓慢升压，达到试验压力后，稳压30min后，管网无泄漏、无变形，且压力降不大于0.05MPa。",[375,377,379,381],{"key":20,"text":376,"correct":22},"最高点",{"key":24,"text":378,"correct":22},"中间点",{"key":28,"text":380,"correct":26},"最低点",{"key":31,"text":382,"correct":22},"末端",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":28,"analysis":33},937476,"消防给水系统管网水压严密性试验在水压强度试验和管网冲洗合格后进行。试验压力为设计工作压力，稳压（ ）h，应无泄漏。",[387,389,391,393],{"key":20,"text":388,"correct":22},"6",{"key":24,"text":390,"correct":22},"12",{"key":28,"text":392,"correct":26},"24",{"key":31,"text":394,"correct":22},"48",{"id":396,"libraryId":5,"type":15,"typeLabel":16,"stem":397,"options":398,"answer":24,"analysis":33},937477,"下列消防工程建设过程的描述中不正确的是（ ）。",[399,401,403,405],{"key":20,"text":400,"correct":22},"为确保消防设施施工安装质量，消防设施安装调试、技术检测应由具有相应等级资质的施工单位、消防技术服务机构承担。",{"key":24,"text":402,"correct":26},"施工单位采购的各类消防设施的设备、组件及材料等到达施工现场后，监理单位组织实施现场检查。",{"key":28,"text":404,"correct":22},"各类消防设施施工结束后，由施工单位或者其委托的具有调试能力的其他单位组织实施消防设施调试，调试工作包括各类消防设施的单机设备、组件调试和系统联动调试等内容。",{"key":31,"text":406,"correct":22},"消防设施施工结束后，由建设单位组织设计、施工、监理等单位进行包括消防设施在内的建设工程竣工验收。",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":31,"analysis":33},937478,"下列不属于消防设计文件的是（ ）。",[411,413,415,417],{"key":20,"text":412,"correct":22},"消防设施设计平面图图样",{"key":24,"text":414,"correct":22},"消防设施设计系统图图样",{"key":28,"text":416,"correct":22},"消防设施施工详图图样",{"key":31,"text":418,"correct":26},"消防设施设计人员名单",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},937479,"水泵的分体安装。水泵在装配前，应首先检查零件主要装配尺寸及影响装配的缺陷，清洗零件后方可进行装配。分体安装水泵时，应（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"先安装电动机再安装水泵",{"key":24,"text":426,"correct":26},"先安装水泵再安装电动机",{"key":28,"text":428,"correct":22},"先安装进出水管再安装水泵",{"key":31,"text":430,"correct":22},"先安装进水管再安装出水管",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":31,"analysis":33},937480,"制作安装的管道支架的具体要求如下，错误的是（ ）。",[435,437,439,441],{"key":20,"text":436,"correct":22},"管道支吊架材料除设计文件另有规定外，一般采用Q235普通碳素钢型制作",{"key":24,"text":438,"correct":22},"管道支吊架上面的孔洞采用电钻加工，不得用氧乙炔割孔",{"key":28,"text":440,"correct":22},"管道支吊架成品后进行防腐处理，防腐涂层完整、厚度均匀",{"key":31,"text":442,"correct":26},"管卡应在现场采用圆钢或扁钢制作，不宜采用镀锌成形件",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":28,"analysis":33},937481,"有振动的场所和埋地管道应采用柔性接头，其他场所宜采用刚性接头，当采用刚性接头时，每隔（ ）个刚性接头处应设置一个挠性接头。",[447,449,451,453],{"key":20,"text":448,"correct":22},"2~3",{"key":24,"text":450,"correct":22},"3~4",{"key":28,"text":452,"correct":26},"4~5",{"key":31,"text":454,"correct":22},"5~6",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":28,"analysis":33},937482,"下列关于消防给水管网维护管理的说法中错误的是（ ）。",[459,461,463,465],{"key":20,"text":460,"correct":22},"每季度对系统所有的末端试水阀和报警阀的放水试验阀进行一次放水试验，并应检查系统启动、报警功能以及出水情况是否正常",{"key":24,"text":462,"correct":22},"每月对电动阀和电磁阀的供电和启闭性能进行检测",{"key":28,"text":464,"correct":26},"在市政供水阀门处于完全开启状态时，每周对倒流防止器的压差进行检测",{"key":31,"text":466,"correct":22},"每天对水源控制阀进行外观检查，并应保证系统处于无故障状态",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":20,"analysis":33},937483,"下列关于管道施工安装的说法中不正确的是（ ）。",[471,473,475,477],{"key":20,"text":472,"correct":26},"公称直径为200mm的管道支架间隔距离为10m",{"key":24,"text":474,"correct":22},"管道应涂红色环圈标志，红色环圈标志宽度不应小于20mm，间隔不宜大于4m",{"key":28,"text":476,"correct":22},"配水管道吊架的承受力应为充满水管重的五倍，并能支撑支撑整个消防给水系统",{"key":31,"text":478,"correct":22},"配水立管长度超过15m的，应每隔15米处至少设置一个防晃支架",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":31,"analysis":33},937484,"下列消防给水系统在火灾时无须启动消防水泵直接加压的是（ ）。",[483,484,486,487],{"key":20,"text":220,"correct":22},{"key":24,"text":485,"correct":22},"干式消防竖管",{"key":28,"text":214,"correct":22},{"key":31,"text":216,"correct":26},{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":33},937485,"在消防给水系统中，平时不能满足水灭火系统所需要的工作压力和流量，火灾发生时需启动消防泵灭火的系统是（ ）。",[492,493,494,495],{"key":20,"text":214,"correct":22},{"key":24,"text":220,"correct":26},{"key":28,"text":218,"correct":22},{"key":31,"text":216,"correct":22},{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":31,"analysis":33},937486,"在消防给水系统中，临时高压消防给水系统是按照（ ）进行分类的。",[500,502,504,506],{"key":20,"text":501,"correct":22},"管网形式",{"key":24,"text":503,"correct":22},"灭火方式",{"key":28,"text":505,"correct":22},"用途",{"key":31,"text":507,"correct":26},"水压",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":20,"analysis":33},937487,"下列关于消防水源的说法，不正确的是（ ）。",[512,514,516,518],{"key":20,"text":513,"correct":26},"市政给水、消防水池、天然水源等可作为消防水源，并宜采用消防水池",{"key":24,"text":515,"correct":22},"雨水清水池、中水清水池、水景和游泳池可作为备用消防水源",{"key":28,"text":517,"correct":22},"消防给水管道内平时所充水的pH值应为6.0~9.0",{"key":31,"text":519,"correct":22},"雨水清水池、中水清水池、水景和游泳池可以作为消防水源",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":20,"analysis":33},937488,"下列关于消防水池和消防水箱的施工安装要求的说法，正确的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":26},"消防水池和消防水箱出水管或水泵吸水管应满足最低有效水位出水不掺气的技术要求",{"key":24,"text":527,"correct":22},"钢板等制作的消防水池和消防水箱的进出水等管道应加设防水套管",{"key":28,"text":529,"correct":22},"钢筋混凝土制作的消防水池和消防水箱的进出水等管道宜采用法兰连接",{"key":31,"text":531,"correct":22},"消防水池、消防水箱的溢流管、泄水管应与生产或生活用水的排水系统直接相连",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":24,"analysis":33},937489,"根据《消防给水及消火栓系统技术规范》GB 50974，下列关于消防给水及消火栓系统试压和冲洗要求的说法，不正确的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":22},"冲洗管道直径大于DN100时，应对其死角和底部进行振动，但不应损伤管道",{"key":24,"text":539,"correct":26},"系统试压过程中，当出现泄漏时，应停止试压，无需放空试验介质消除缺陷后，应重新再试",{"key":28,"text":541,"correct":22},"管网冲洗应按先室外，后室内，先地下，后地上的顺序进行",{"key":31,"text":543,"correct":22},"室内部分管网冲洗应按供水干管、水平管和立管的顺序进行",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":28,"analysis":33},937490,"某民用建筑的消火栓系统施工完毕后，对其进行试压和冲洗，下列关于消火栓系统试压和冲洗的要求，正确的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"水压强度试验对管网注水时，应将管网内的空气排净，并应缓慢升压，达到试验压力后，稳压30min后，管网应无泄漏、无变形，且压力降不应大于0.01MPa",{"key":24,"text":551,"correct":22},"气压严密性试验的介质宜采用空气或氮气，试验压力应为0.28MPa，且稳压24h，压力降不应大于0.05MPa",{"key":28,"text":553,"correct":26},"水压强度试验的测试点应设在系统管网的最低点",{"key":31,"text":555,"correct":22},"水压严密性试验应在水压强度试验和管网冲洗合格后进行，试验压力应为系统工作压力，稳压48h，应无泄漏",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":31,"analysis":33},937491,"下列关于消防给水系统架空管道安装要求的说法，不正确的是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"架空管道不应安装使用钢丝网骨架塑料复合管等非金属管道",{"key":24,"text":563,"correct":22},"消防给水管穿过建筑物承重墙或基础时，应预留洞口，洞口高度应保证管顶上部净空不小于建筑物的沉降量，不宜小于0.1m",{"key":28,"text":565,"correct":22},"架空管道穿过墙体或楼板时应加设套管，套管长度不应小于墙体厚度，或应高出楼面或地面50mm",{"key":31,"text":567,"correct":26},"架空管道应采用热浸镀锌钢管或球墨铸铁管",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":28,"analysis":33},937492,"某建筑高度为40m的商场，屋顶设有水箱间，对该建筑的高位消防水箱进行验收，下列检查结果中，不符合规范要求的是（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"水箱顶部设有人孔，水箱顶板面与上面建筑本体板底的净空为0.9m",{"key":24,"text":575,"correct":22},"有管道的侧面，管道外壁与建筑本体墙面之间的通道宽度为0.7m",{"key":28,"text":577,"correct":26},"消防水箱支墩的高度为500mm",{"key":31,"text":579,"correct":22},"消防水箱无管道的侧面与建筑本体结构墙面之间的净距为0.8m",{"id":581,"libraryId":5,"type":120,"typeLabel":121,"stem":582,"options":583,"answer":594,"analysis":33},937493,"可用作消防水源的有市政给水、消防水池、天然水源、消防水箱和其他几类水源。其中下列消防水池（消防水箱）作为消防水源的条件说法中，正确的是（ ）。",[584,586,588,590,592],{"key":20,"text":585,"correct":26},"消防水池有足够的有效容积",{"key":24,"text":587,"correct":26},"供消防车取水的消防水池应设取水口（井）",{"key":28,"text":589,"correct":26},"在与生活或其他用水合用时，消防水池应有确保消防用水不被挪用的技术措施",{"key":31,"text":591,"correct":22},"消防水池无需采取防冻措施",{"key":133,"text":593,"correct":26},"取水设施有相应保护设施","ABCE",{"id":596,"libraryId":5,"type":120,"typeLabel":121,"stem":597,"options":598,"answer":609,"analysis":33},937494,"消防给水管网施工完成后，要进行试压和冲洗，下列管网试压和冲洗要求正确的是（ ）。",[599,601,603,605,607],{"key":20,"text":600,"correct":26},"系统试压完成后，要及时拆除所有临时盲板及试验用的管道",{"key":24,"text":602,"correct":22},"管网冲洗顺序先室内，后室外；先地上，后地下",{"key":28,"text":604,"correct":26},"管网冲洗的水流方向要与灭火时管网的水流方向一致",{"key":31,"text":606,"correct":26},"管网冲洗应连续进行。当出口处水的颜色、透明度与入口处水的颜色、透明度基本一致时，冲洗方可结束",{"key":133,"text":608,"correct":26},"管网冲洗宜设临时专用排水管道，其排放应畅通和安全。排水管道的截面面积不小于被冲洗管道截面面积的60%","ACDE",{"id":611,"libraryId":5,"type":120,"typeLabel":121,"stem":612,"options":613,"answer":594,"analysis":33},937495,"可用作消防水源的有（ ）。",[614,616,618,620,622],{"key":20,"text":615,"correct":26},"市政给水",{"key":24,"text":617,"correct":26},"消防水池",{"key":28,"text":619,"correct":26},"天然水源",{"key":31,"text":621,"correct":22},"游泳池",{"key":133,"text":623,"correct":26},"消防水箱（高位消防水池）",{"id":625,"libraryId":5,"type":120,"typeLabel":121,"stem":626,"options":627,"answer":638,"analysis":33},937496,"海南某四层商业建筑消防验收中，下列关于泵接合器的检查和安装的说法中正确的是（ ）。",[628,630,632,634,636],{"key":20,"text":629,"correct":26},"组装式水泵接合器组件中，止回阀的安装方向从接口指向控制阀方向",{"key":24,"text":631,"correct":22},"地上式水泵接合器安装在接近机动车道的位置",{"key":28,"text":633,"correct":22},"水泵接合器与室外消火栓的距离为10m",{"key":31,"text":635,"correct":22},"某墙壁水泵接合器安装高度距地面1.1m",{"key":133,"text":637,"correct":26},"某墙壁水泵接合器安装位置距离墙面门窗洞口的净距为2m","AE",[640,643,646,649,652,655],{"id":15,"name":641,"category":7,"favorite":642},"领导干部任职前廉政法规知识测试题",92,{"id":644,"name":645,"category":7,"favorite":15},595,"建筑结构与设备",{"id":647,"name":648,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":650,"name":651,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":653,"name":654,"category":7,"favorite":8},534,"BIM工程师",{"id":656,"name":654,"category":7,"favorite":8},535]