[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-52":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":654},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,52,50,2974,[13,34,45,57,69,81,93,105,117,129,141,153,171,186,200,215,229,244,258,272,287,301,315,326,338,350,362,374,386,398,406,418,430,444,459,473,488,500,512,524,536,548,560,572,584,596,608,620,632,644],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},937246,1,"单选题","影剧院、礼堂用的面光灯、耳光灯与可燃物之间的距离不应小于（ ）m。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","0.3",false,{"key":24,"text":25,"correct":26},"B","0.5",true,{"key":28,"text":29,"correct":22},"C","0.7",{"key":31,"text":32,"correct":22},"D","1.2","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},937247,"储存可燃物的仓库及类似场所照明光源应采用冷光源，其垂直下方与堆放可燃物品水平间距不应小于（ ）m，不应设置移动式照明灯具；应采用有防护罩的灯具和墙壁开关，不得使用无防护罩的灯具和拉线开关。",[38,39,41,43],{"key":20,"text":25,"correct":26},{"key":24,"text":40,"correct":22},"1.0",{"key":28,"text":42,"correct":22},"1.5",{"key":31,"text":44,"correct":22},"2.0",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":31,"analysis":33},937248,"下列关于空调器具电气防火要求及技术措施，错误的是（ ）。",[49,51,53,55],{"key":20,"text":50,"correct":22},"空调器具应单独供电，电源线应设置短路、过载保护",{"key":24,"text":52,"correct":22},"空调不要靠近窗帘、门帘等悬挂物，以免卷入电机而使电机发热起火",{"key":28,"text":54,"correct":22},"由于空调不具备防雷功能，雷雨天气时，最好不要使用空调",{"key":31,"text":56,"correct":26},"空调电源插头的容量应大于插座的容量且匹配",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":28,"analysis":33},937249,"下列关于电气防火检查的平面布置要求描述中，不正确的是（ ）。",[61,63,65,67],{"key":20,"text":62,"correct":22},"室外变、配电装置距堆场、可燃液体储罐和甲、乙类厂房库房应不小于25m",{"key":24,"text":64,"correct":22},"室外变、配电装置距其他建筑物应不小于1Om",{"key":28,"text":66,"correct":26},"室外变、配电装置距液化石油气罐应不小于30m",{"key":31,"text":68,"correct":22},"石油化工装置的变、配电室还应布置在装置的一侧，并位于爆炸危险区范围以外",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":24,"analysis":33},937250,"预防电气线路短路的措施不包括（ ）。",[73,75,77,79],{"key":20,"text":74,"correct":22},"在线路上应按规定安装断路器或熔断器",{"key":24,"text":76,"correct":26},"铜、铝线相接，宜采用铜铝过渡接头，也可采用在铜线接头处烫锡",{"key":28,"text":78,"correct":22},"安装线路时，电线之间、电线与建筑构件或树木之间要保持一定距离",{"key":31,"text":80,"correct":22},"在距地面2m高以内的电线，应用钢管或硬质塑料管保护，以防绝缘遭受损坏",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},937251,"下列消防配电电缆在明敷设时可不穿金属导管或采用封闭式金属槽盒保护的是（ ）。",[85,87,89,91],{"key":20,"text":86,"correct":22},"低烟低卤阻燃电缆",{"key":24,"text":88,"correct":26},"矿物绝缘不燃性电缆",{"key":28,"text":90,"correct":22},"有机耐火电缆",{"key":31,"text":92,"correct":22},"普通阻燃电缆",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":28,"analysis":33},937252,"下列关于消防用电设备供配电系统的说法，不正确的是（ ）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"建筑物内设变电所时，消防电源应从变电所内低压侧封闭母线处或进线柜处分出",{"key":24,"text":100,"correct":22},"一级耐火等级民用建筑内用作应急电源的自备发电机组当采用自动启动方式时，应保证在30s内供电",{"key":28,"text":102,"correct":26},"水泵控制柜等消防电气控制装置不应采用降压启动方式",{"key":31,"text":104,"correct":22},"为消防电梯供电的末端配电箱要设置双电源自动切换装置",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":28,"analysis":33},937253,"下列关于电缆竖井在防火封堵时的说法，不正确的是（ ）。",[109,111,113,115],{"key":20,"text":110,"correct":22},"电缆竖井应采用矿棉板加膨胀型防火堵料组合成的膨胀型防火封堵系统",{"key":24,"text":112,"correct":22},"封堵处应采用角钢或槽钢托架进行加固，应能承载检修人员的荷载",{"key":28,"text":114,"correct":26},"封堵垂直段竖井时，在封堵处上方，应使用容重为150kg\u002F?以上的矿棉板",{"key":31,"text":116,"correct":22},"封堵系统与电缆的其他空间之间应采用膨胀型防火密封胶封堵，密封胶厚度突出防火封堵系统面不应小于13mm",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":33},937254,"室外变、配电站距甲类厂房的防火间距不应小于（ ）m。",[121,123,125,127],{"key":20,"text":122,"correct":22},"15",{"key":24,"text":124,"correct":26},"25",{"key":28,"text":126,"correct":22},"30",{"key":31,"text":128,"correct":22},"50",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":28,"analysis":33},937255,"户内电压为10kV以上、总油量为800kg的充油设备应安装在（ ）。",[133,135,137,139],{"key":20,"text":134,"correct":22},"两侧有隔板的间隔内",{"key":24,"text":136,"correct":22},"有防爆隔墙的间隔内",{"key":28,"text":138,"correct":26},"单独的防爆间隔内",{"key":31,"text":140,"correct":22},"单独的防爆建筑内",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":31,"analysis":33},937256,"某单位对其内部的低压配电和控制电器防火措施进行了检查，发现如下情况，其中不符合相关规范要求的是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"接线端子接线采用有电镀金属层防锈的螺栓和螺钉连接",{"key":24,"text":148,"correct":22},"调阅资料发现控制柜内的接触器每月检查维修一次",{"key":28,"text":150,"correct":22},"配电柜金属外壳、框架的接地（P体采用镀锌扁钢",{"key":31,"text":152,"correct":26},"低压配电柜一个端子上连接2根导线，且2根导线线径不同",{"id":154,"libraryId":5,"type":155,"typeLabel":156,"stem":157,"options":158,"answer":170,"analysis":33},937257,2,"多选题","下列关于低压配电和控制电器装置中启动器的叙述正确的是（ ）。",[159,161,163,165,167],{"key":20,"text":160,"correct":26},"要定期检查触头表面状况",{"key":24,"text":162,"correct":22},"若发现触头表面粗糙，要以细锉修整或者以砂纸打磨",{"key":28,"text":164,"correct":26},"对于充油式产品的触头，应在油箱外修整，以免油被污染，使其绝缘强度降低",{"key":31,"text":166,"correct":26},"对于手动式减压启动器，当电动机运行过程中因失电压而停转时，应及时将手柄扳回停止位置，以防电压恢复后电动机自行全压起动，必要时另装一个失电压脱扣器",{"key":168,"text":169,"correct":26},"E","手动式启动器的操作机械应保持灵活，并定期添加润滑剂","ACDE",{"id":172,"libraryId":5,"type":155,"typeLabel":156,"stem":173,"options":174,"answer":185,"analysis":33},937258,"（ ）等消防电气控制装置不应采用变频启动方式。",[175,177,179,181,183],{"key":20,"text":176,"correct":26},"水泵控制柜",{"key":24,"text":178,"correct":26},"风机控制柜",{"key":28,"text":180,"correct":22},"消防应急照明供电控制柜",{"key":31,"text":182,"correct":22},"疏散指示系统供电控制柜",{"key":168,"text":184,"correct":22},"消防控制室供电控制柜","AB",{"id":187,"libraryId":5,"type":155,"typeLabel":156,"stem":188,"options":189,"answer":199,"analysis":33},937259,"电气线路防火措施包括预防电气线路短路的措施、预防电气线路过载的措施和预防电气线路接触电阻过大的措施。下列属于预防电气线路过载的措施有（ ）。",[190,191,193,195,197],{"key":20,"text":74,"correct":22},{"key":24,"text":192,"correct":26},"严禁滥用铜丝、铁丝代替熔断器的熔丝",{"key":28,"text":194,"correct":26},"严禁随意增加用电设备，尤其是大功率用电设备",{"key":31,"text":196,"correct":22},"导线与导线、导线与电气设备的连接必须牢固可靠",{"key":168,"text":198,"correct":22},"铜线、铝线相接，宜采用铜铝过渡接头，也可采用在铜线接头处搪锡","BC",{"id":201,"libraryId":5,"type":155,"typeLabel":156,"stem":202,"options":203,"answer":214,"analysis":33},937260,"下列关于照明灯具在特殊场所的安装，正确的是（ ）。",[204,206,208,210,212],{"key":20,"text":205,"correct":26},"卤素灯、60W以上的白炽灯等高温照明灯具不应设置在火灾危险性场所",{"key":24,"text":207,"correct":22},"产生腐蚀性气体的蓄电池室等场所应采用敞开型灯具",{"key":28,"text":209,"correct":22},"在有尘埃的场所，可以采用任何类型的灯具",{"key":31,"text":211,"correct":26},"重要场所的大型灯具，应安装防止玻璃罩破裂后向下飞溉的保护设施",{"key":168,"text":213,"correct":26},"库房照明宜采用投光灯采光","ADE",{"id":216,"libraryId":5,"type":155,"typeLabel":156,"stem":217,"options":218,"answer":170,"analysis":33},937261,"建筑物内常用的电气设备和装置包括变、配电装置以及安装在装置中的低压配电和控制电器。下列属于变、配电装置的防火措施有（ ）。",[219,221,223,225,227],{"key":20,"text":220,"correct":26},"变压器保护",{"key":24,"text":222,"correct":22},"隔热保护",{"key":28,"text":224,"correct":26},"过电流、短路保护措施",{"key":31,"text":226,"correct":26},"接地措施",{"key":168,"text":228,"correct":26},"剩余电流保护装置",{"id":230,"libraryId":5,"type":155,"typeLabel":156,"stem":231,"options":232,"answer":243,"analysis":33},937262,"下列选项中属于功率为600W的灯具与可燃物之间的安全距离的是（ ）。",[233,235,237,239,241],{"key":20,"text":234,"correct":22},"0.5m",{"key":24,"text":236,"correct":22},"0.6m",{"key":28,"text":238,"correct":26},"0.7m",{"key":31,"text":240,"correct":26},"0.8m",{"key":168,"text":242,"correct":26},"0.9m","CDE",{"id":245,"libraryId":5,"type":155,"typeLabel":156,"stem":246,"options":247,"answer":257,"analysis":33},937263,"变、配电站（室）的设置正确的是（ ）。",[248,250,252,254,255],{"key":20,"text":249,"correct":22},"距甲、乙类厂房库房不应小于20m",{"key":24,"text":251,"correct":26},"距其他建筑物不应小于10m",{"key":28,"text":253,"correct":22},"距液化石油气罐不应小于25m",{"key":31,"text":68,"correct":26},{"key":168,"text":256,"correct":26},"距堆场、可燃液体储罐不应小于25m","BDE",{"id":259,"libraryId":5,"type":155,"typeLabel":156,"stem":260,"options":261,"answer":214,"analysis":33},937264,"防护电器的设置参数应满足（ ）。",[262,264,266,268,270],{"key":20,"text":263,"correct":26},"额定电流不应小于回路的计算负载电流",{"key":24,"text":265,"correct":22},"整定电流不应大于回路的计算负载电流",{"key":28,"text":267,"correct":22},"额定电流不应小于回路的允许持续载流量",{"key":31,"text":269,"correct":26},"整定电流不应大于回路的允许持续载流量",{"key":168,"text":271,"correct":26},"保证防护电器有效动作的电流不应大于回路载流量的1.45倍",{"id":273,"libraryId":5,"type":155,"typeLabel":156,"stem":274,"options":275,"answer":286,"analysis":33},937265,"室外变、配电装置距液化石油气罐的距离符合规定的是（ ）。",[276,278,280,282,284],{"key":20,"text":277,"correct":22},"20m",{"key":24,"text":279,"correct":22},"25m",{"key":28,"text":281,"correct":22},"30m",{"key":31,"text":283,"correct":26},"35m",{"key":168,"text":285,"correct":26},"40m","DE",{"id":288,"libraryId":5,"type":155,"typeLabel":156,"stem":289,"options":290,"answer":300,"analysis":33},937266,"在电气防火措施中，防护电器的设置参数应满足的要求是（ ）。",[291,293,295,297,299],{"key":20,"text":292,"correct":26},"防护电器的额定电流或整定电流不应小于回路的计算负载电流",{"key":24,"text":294,"correct":22},"防护电器的额定电流或整定电流不应大于回路的计算负载电流",{"key":28,"text":296,"correct":26},"防护电器的额定电流或整定电流不应大于回路的允许持续载流量",{"key":31,"text":298,"correct":22},"防护电器的额定电流或整定电流不应小于回路的允许持续载流量",{"key":168,"text":271,"correct":26},"ACE",{"id":302,"libraryId":5,"type":155,"typeLabel":156,"stem":303,"options":304,"answer":170,"analysis":33},937267,"为防止火灾通过消防用电设备供电线路传输，应对消防用电设备供电线路采取防火封堵措施，下列部位需要采取防火封堵措施是（ ）。",[305,307,309,311,313],{"key":20,"text":306,"correct":26},"电缆桥架沿竖井垂直敷设穿越楼板处",{"key":24,"text":308,"correct":22},"电缆隧道每隔30m处",{"key":28,"text":310,"correct":26},"电缆引至配电柜、控制柜的开孔部位",{"key":31,"text":312,"correct":26},"电缆穿越电缆沟的隔墙处",{"key":168,"text":314,"correct":26},"管线进出竖井处",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":20,"analysis":33},937268,"高危险场所灯具光源应急点亮的响应时间不应大于（ ）s",[319,321,323,324],{"key":20,"text":320,"correct":26},"0.25",{"key":24,"text":322,"correct":22},"5",{"key":28,"text":122,"correct":22},{"key":31,"text":325,"correct":22},"20",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":28,"analysis":33},937269,"消防应急照明系统和疏散指示系统的组件安装需要满足相关规范的规定和要求，下列关于系统主要组件安装的说法中不正确的是（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"消防应急照明灯具上边与顶棚距离宜大于200mm",{"key":24,"text":333,"correct":22},"标志灯具表面应与地面平行，与地面高度差不宜大于3mm",{"key":28,"text":335,"correct":26},"楼层标志灯应安装在楼梯间内朝向楼梯的侧面墙上",{"key":31,"text":337,"correct":22},"特大型，大型，中型标志灯底边距地面高度不宜小于3米，且不宜大于6米",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":28,"analysis":33},937270,"下列关于消防应急灯具的说法中不正确的是（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"消防应急灯具包括消防应急标志灯具和消防应急照明灯具",{"key":24,"text":345,"correct":22},"室内高度不大于3.5米的场所，标志灯底边离门框距离不应大于200mm",{"key":28,"text":347,"correct":26},"标志灯边缘与地面垂直距离高度不应大于3mm",{"key":31,"text":349,"correct":22},"当条件限制时，照明灯可安装在走道侧面墙上，但安装高度不应在距地面1~2米之间",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":28,"analysis":33},937271,"应急照明控制器的控制线路要单独穿管，引入应急照明控制器的电缆或导线，配线应整齐，避免交叉，并应固定牢靠；电缆芯和导线应留有不小于（ ）的余量",[354,356,358,360],{"key":20,"text":355,"correct":22},"100mm",{"key":24,"text":357,"correct":22},"150mm",{"key":28,"text":359,"correct":26},"200mm",{"key":31,"text":361,"correct":22},"250mm",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":28,"analysis":33},937272,"下列关于消防应急标志灯具安装的说法，不正确的是（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":22},"消防应急标志灯具吊装时，应采用金属吊杆或吊链固定在建筑构件上",{"key":24,"text":369,"correct":22},"方向标志灯安装在疏散走道的墙面上时，底边距地面的高度应小于1m",{"key":28,"text":371,"correct":26},"疏散通道上的方向标志灯只能在顶棚附近吊装或在墙面、柱面上安装",{"key":31,"text":373,"correct":22},"安装的方向标志灯的箭头指示方向应与疏散指示方案一致",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":28,"analysis":33},937273,"下列关于消防应急照明系统的组件安装的说法，不正确的是（ ）。",[378,380,382,384],{"key":20,"text":379,"correct":22},"应急照明配电箱落地安装时，底边宜高出（楼）地面100mm~200mm",{"key":24,"text":381,"correct":22},"应急照明集中电源落地安装时，底边宜高出（楼）地面100mm~200mm",{"key":28,"text":383,"correct":26},"应急照明控制器落地安装时，底边宜高出（楼）地面50mm以上",{"key":31,"text":385,"correct":22},"消防应急照明灯具安装在距地面不大于1m的侧面墙上时，凸出墙面最大水平距离不应超过20mm",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":20,"analysis":33},937274,"方向标志灯安装在疏散走道地面上时，标志灯表面应与地面平行，高于地面距离不应大于（ ）mm，标志灯边缘与地面垂直距离高度不应大于（ ）mm。",[390,392,394,396],{"key":20,"text":391,"correct":26},"3,1",{"key":24,"text":393,"correct":22},"2,1",{"key":28,"text":395,"correct":22},"1.5,1",{"key":31,"text":397,"correct":22},"5,2",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":28,"analysis":33},937275,"系统导线敷设结束后，应用500V兆欧表测量每个回路导线对地的绝缘电阻，且绝缘电阻值不应小于（ ）MQ。",[402,403,404,405],{"key":20,"text":322,"correct":22},{"key":24,"text":122,"correct":22},{"key":28,"text":325,"correct":26},{"key":31,"text":124,"correct":22},{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":28,"analysis":33},937276,"消防技术服务机构对某建筑的自带电源集中控制型消防应急照明及疏散指示系统进行检测，发现如下情况，其中不符合国家现行消防技术标准的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"应急照明控制器落地安装，底边高出地面150mm",{"key":24,"text":413,"correct":22},"首层防烟楼梯间前室的安全出口标志灯安装在内侧上方居中部位",{"key":28,"text":415,"correct":26},"灯具的通信线路和配电线路共管敷设",{"key":31,"text":417,"correct":22},"明敷的配电线路在接线盒处的吊点距接线盒0.2m",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},937277,"某办公楼设置有火灾自动报警系统和集中电源非集中控制型消防应急照明和疏散指示系统，对该系统进行调试，使火灾报警控制器发出火灾报警输出信号，下列结果不正确的是（ ）。",[422,424,426,428],{"key":20,"text":423,"correct":26},"所配接的持续型照明灯的光源保持正常状态",{"key":24,"text":425,"correct":22},"集中电源转入蓄电池输出",{"key":28,"text":427,"correct":22},"所配接的非持型续照明灯的光源应急点亮",{"key":31,"text":429,"correct":22},"灯具应急点亮的响应时间为3s",{"id":431,"libraryId":5,"type":155,"typeLabel":156,"stem":432,"options":433,"answer":214,"analysis":33},937278,"系统主要组件安装应符合（ ）。",[434,436,438,440,442],{"key":20,"text":435,"correct":26},"消防应急照明控制器应安装牢固，不得倾斜",{"key":24,"text":437,"correct":22},"应急照明控制器落地安装时，其底边宜高出地坪1.3~1.5m",{"key":28,"text":439,"correct":22},"应急照明设备在电气竖井内安装时，应采用上出口进线方式",{"key":31,"text":441,"correct":26},"集中电源安装时，其底边宜高出地（楼）面100~200mm",{"key":168,"text":443,"correct":26},"设备接地应牢固，并应设置明显标识",{"id":445,"libraryId":5,"type":155,"typeLabel":156,"stem":446,"options":447,"answer":458,"analysis":33},937279,"消防应急标志灯具安装在地面上时，下列设置正确的是（ ）。",[448,450,452,454,456],{"key":20,"text":449,"correct":26},"灯具的所有金属构件应采用耐腐蚀构件或做防腐处理",{"key":24,"text":451,"correct":26},"电源连接和控制线连接应采用密封胶密封",{"key":28,"text":453,"correct":26},"标志灯应安装在疏散走道、通道的中心位置",{"key":31,"text":455,"correct":22},"标志灯具表面与地面高度差不宜大于5mm",{"key":168,"text":457,"correct":26},"标志灯表面应与地面平行","ABCE",{"id":460,"libraryId":5,"type":155,"typeLabel":156,"stem":461,"options":462,"answer":286,"analysis":33},937280,"对建筑的消防应急照明和疏散指示系统进行检测验收时应包含系统功能的相关内容，下列系统功能检测验收项目中，不属于设置区域火灾自动报警系统场所非集中控制型系统应包含的有（ ）。",[463,465,467,469,471],{"key":20,"text":464,"correct":22},"系统自动应急启动功能",{"key":24,"text":466,"correct":22},"系统手动应急启动功能",{"key":28,"text":468,"correct":22},"系统正常工作模式",{"key":31,"text":470,"correct":26},"系统主电源断电控制功能",{"key":168,"text":472,"correct":26},"系统正常照明电源断电控制功能",{"id":474,"libraryId":5,"type":155,"typeLabel":156,"stem":475,"options":476,"answer":487,"analysis":33},937281,"某地对多栋建筑的消防应急照明和疏散指示系统进行验收，经过分析整理，得出下列判定结果，其中应给出验收通过结论的有（ ）。",[477,479,481,483,485],{"key":20,"text":478,"correct":22},"A=0，B=3，B+C=检查项目数量的5%",{"key":24,"text":480,"correct":22},"A=1，B=0，B+C=检查项目数量的5%",{"key":28,"text":482,"correct":26},"A=0，B=2，B+C=检查项目数量的3%",{"key":31,"text":484,"correct":22},"A=1，B=1，B+C=检查项目数量的5%",{"key":168,"text":486,"correct":26},"A=0，B=1，B+C=检查项目数量的3%","CE",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":33},937282,"消防应急标志灯具安装在疏散走道、通道转角处的上方或两侧时，标志灯与转角处边墙的距离不应大于（ ）m",[492,494,496,498],{"key":20,"text":493,"correct":22},"2",{"key":24,"text":495,"correct":26},"1",{"key":28,"text":497,"correct":22},"2.2",{"key":31,"text":499,"correct":22},"2.5",{"id":501,"libraryId":5,"type":15,"typeLabel":16,"stem":502,"options":503,"answer":28,"analysis":33},937283,"下列不符合消防应急标志灯具的安装要求的是（ ）。",[504,506,508,510],{"key":20,"text":505,"correct":22},"低位安装在疏散走道及其转角处时，应安装在距地面（楼面）1m以下的墙上",{"key":24,"text":507,"correct":22},"安装在地面上时，灯具的所有金属构件应采用耐腐蚀构件或做防腐处理",{"key":28,"text":509,"correct":26},"标志灯具表面应与地面平行，与地面高度差不宜大于3mm，与地面接触边缘不宜大于2mm",{"key":31,"text":511,"correct":22},"标志灯的疏散面应与疏散方向垂直，箭头应指向安全出口或疏散门",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":28,"analysis":33},937284,"应急照明控制器落地安装时宜高出地面（ ）mm",[516,518,520,522],{"key":20,"text":517,"correct":22},"10~30mm",{"key":24,"text":519,"correct":22},"30~50mm",{"key":28,"text":521,"correct":26},"100~200mm",{"key":31,"text":523,"correct":22},"200~300mm",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":28,"analysis":33},937285,"根据现行国家消防技术标准，关于建筑内消防应急照明和疏散指示标志的检查结果中，不符合标准要求的是（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"出口标志灯安装在安全出口或疏散门内侧上方居中的位置",{"key":24,"text":531,"correct":22},"多信息复合标志灯，安装在疏散走道的顶部",{"key":28,"text":533,"correct":26},"灯光疏散指示标志均设置在疏散走道的顶棚上",{"key":31,"text":535,"correct":22},"应急照明配电箱落地安装时，底边高出地（楼）面100~200mm",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":24,"analysis":33},937286,"下列部件中，自带电源集中控制型系统内不包含的是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":22},"自带电源型消防应急灯具",{"key":24,"text":543,"correct":26},"应急照明集中电源",{"key":28,"text":545,"correct":22},"应急照明控制器",{"key":31,"text":547,"correct":22},"应急照明配电箱",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":24,"analysis":33},937287,"某单位内的消防应急照明及疏散指示系统采用自带电源非集中控制型系统，消防机构对消防应急照明灯具进行检查时发现如下情况，其中符合国家现行消防技术标准的是（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":22},"消防应急照明灯具与供电线路之间使用插头连接，插头可以用手轻易拔下",{"key":24,"text":555,"correct":26},"消防应急照明灯具在侧面墙上顶部安装，其底部距地面距离2.5m",{"key":28,"text":557,"correct":22},"手动操作应急照明配电箱的应急启动控制按钮，其所配接的灯具未转入应急状态",{"key":31,"text":559,"correct":22},"随机抽查两个灯具，按动灯具上的试验按钮，无法转入应急状态",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":28,"analysis":33},937288,"下列关于消防应急照明控制器安装的说法，正确的是（ ）。",[564,566,568,570],{"key":20,"text":565,"correct":22},"应急照明控制器端子板的每个接线端，接线不得超过3根",{"key":24,"text":567,"correct":22},"应急照明控制器的主电源应设置明显的永久性标识，并应直接与消防电源连接，外接备用电源可采用电源插头连接",{"key":28,"text":569,"correct":26},"端子板连接的电缆芯和导线，应留有不小于200mm的余量",{"key":31,"text":571,"correct":22},"应急照明控制器在电气竖井内安装时，应采用上出口进线方式",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":31,"analysis":33},937289,"对某建筑的消防应急照明和疏散指示系统进行验收，发现的下列情况，属于B类不合格项的是（ ）。",[576,578,580,582],{"key":20,"text":577,"correct":22},"应急照明配电箱的选型与设计文件不符",{"key":24,"text":579,"correct":22},"部分应急照明灯具未取得国家消防产品市场准入文件",{"key":28,"text":581,"correct":22},"个别应急照明配电箱在系统应急启动时无法切断主电源输出",{"key":31,"text":583,"correct":26},"系统在自带蓄电池供电状态下，持续应急工作时间不符合规定",{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":24,"analysis":33},937290,"下列关于火灾探测器的选择说法中，错误的是（ ）。",[588,590,592,594],{"key":20,"text":589,"correct":22},"对于火灾初期有阴燃阶段，且需要早期探测的场所，宜增设一氧化碳火灾探测器",{"key":24,"text":591,"correct":26},"对火灾发展迅速，可产生大量热、烟和火焰辐射的场所，可选择可燃气体探测器",{"key":28,"text":593,"correct":22},"对于火灾初期有阴燃阶段，产生大量的烟和少量的热，很少或没有火焰辐射的场所，应该选择感烟火灾探测器",{"key":31,"text":595,"correct":22},"对使生产可燃气体或可燃蒸汽的场所，宜选择可燃气体探测器",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":28,"analysis":33},937291,"在火灾发展过程中的温度详见数和火焰详见数通常被用于表示火灾发展的程度，就是说火灾发生后，探测空间温度的感温火灾探测器动作表明火灾已经发展到应该启功自动灭火设施的程度了，所以（ ）火灾探测器经常用于确认火灾并联动自动灭火系统。",[600,602,604,606],{"key":20,"text":601,"correct":22},"点型感烟",{"key":24,"text":603,"correct":22},"点型光电感烟",{"key":28,"text":605,"correct":26},"点型感温",{"key":31,"text":607,"correct":22},"点型火焰探测器",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":28,"analysis":33},937292,"对火灾发展迅速，有强烈的火焰辐射和少量的烟热的场所，应选择（ ）探测器。",[612,614,616,618],{"key":20,"text":613,"correct":22},"感烟",{"key":24,"text":615,"correct":22},"感温",{"key":28,"text":617,"correct":26},"火焰",{"key":31,"text":619,"correct":22},"可燃气体",{"id":621,"libraryId":5,"type":15,"typeLabel":16,"stem":622,"options":623,"answer":31,"analysis":33},937293,"为了迅速而准确地探测出被保护区内发生火灾的部位，需将被保护区按顺序划分成若干探测区域。下列关于火灾探测区域的划分错误的说法是（ ）。",[624,626,628,630],{"key":20,"text":625,"correct":22},"探测区域应按独立房（套）间划分",{"key":24,"text":627,"correct":22},"一个探测区域的面积不宜超过500m2",{"key":28,"text":629,"correct":22},"从主要出入口能看清其内部，且面积不超过1000㎡的房间，也可划为一个探测区域",{"key":31,"text":631,"correct":26},"红外光束感烟火灾探测器和缆式线间感温火灾探测器的探测区域的长度，宜为20m～100m",{"id":633,"libraryId":5,"type":15,"typeLabel":16,"stem":634,"options":635,"answer":24,"analysis":33},937294,"报警区域的划分主要是为了迅速确定报警及火灾发生部位，并解决消防系统的联动设计问题。发生火灾时，涉及发生火灾的防火分区及相邻防火分区的消防设备的联动启动，这些设备需要协调工作，因此需要划分报警区域。下列关于火灾探测区域的划分错误的说法是（ ）。",[636,638,640,642],{"key":20,"text":637,"correct":22},"报警区域应根据防火分区或楼层划分",{"key":24,"text":639,"correct":26},"可将一个防火分区或一个楼层划分为一个报警区域，但报警区域不跨防火分区",{"key":28,"text":641,"correct":22},"电缆隧道的一个报警区域宜由一个封闭长度区间组成，一个报警区域不应超过相连的3个封闭长度区间",{"key":31,"text":643,"correct":22},"甲、乙、丙类液体储罐区的报警区域应由一个储罐区组成，每个50000m3及以上的外浮项储罐应单独划分为一个报警区域",{"id":645,"libraryId":5,"type":15,"typeLabel":16,"stem":646,"options":647,"answer":31,"analysis":33},937295,"某藏书60万册的图书馆，其条形疏散走道宽度为2.1m，长度为51m，该走到顶棚上至少应设置（ ）只点型感烟火灾探测器。",[648,649,651,652],{"key":20,"text":493,"correct":22},{"key":24,"text":650,"correct":22},"3",{"key":28,"text":322,"correct":22},{"key":31,"text":653,"correct":26},"4",[655,658,661,664,667,670],{"id":15,"name":656,"category":7,"favorite":657},"领导干部任职前廉政法规知识测试题",92,{"id":659,"name":660,"category":7,"favorite":15},595,"建筑结构与设备",{"id":662,"name":663,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":665,"name":666,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":668,"name":669,"category":7,"favorite":8},534,"BIM工程师",{"id":671,"name":669,"category":7,"favorite":8},535]