[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-51":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":629},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,51,50,2974,[13,38,53,66,78,86,98,110,122,134,143,155,164,176,188,200,212,224,236,244,254,266,274,287,299,314,329,344,357,370,385,398,413,428,440,453,465,476,486,498,510,524,536,546,559,571,582,596,605,617],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},937196,2,"多选题","在低压配电和控制电器装置中，继电器的场所要做到（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","少震",true,{"key":24,"text":25,"correct":22},"B","少尘",{"key":27,"text":28,"correct":29},"C","通风",false,{"key":31,"text":32,"correct":22},"D","干燥",{"key":34,"text":35,"correct":22},"E","严禁有易燃、易爆物品","ABDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},937197,"当消防用电设备供电线路暗敷设时，要对所穿金属导管或难燃性刚性塑料导管进行保护，并要敷设在不燃烧结构内，保护层厚度可以设置为（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":29},"20mm",{"key":24,"text":45,"correct":29},"25mm",{"key":27,"text":47,"correct":22},"30mm",{"key":31,"text":49,"correct":22},"35mm",{"key":34,"text":51,"correct":22},"40mm","CDE",{"id":54,"libraryId":5,"type":55,"typeLabel":56,"stem":57,"options":58,"answer":20,"analysis":37},937198,1,"单选题","使用燃烧等级为非（ ）级电缆的竖井，每层均应封堵。",[59,60,62,64],{"key":20,"text":20,"correct":22},{"key":24,"text":61,"correct":29},"B1",{"key":27,"text":63,"correct":29},"B2",{"key":31,"text":65,"correct":29},"B3",{"id":67,"libraryId":5,"type":55,"typeLabel":56,"stem":68,"options":69,"answer":27,"analysis":37},937199,"消防用电设备供配电系统启动装置要求，当消防用电负荷为一级时，应设置自动启动装置，并在主电源断电后（ ）s内供电；当消防负荷为二级且采用自动启动方式有困难时，可采用手动启动装置。",[70,72,74,76],{"key":20,"text":71,"correct":29},"10",{"key":24,"text":73,"correct":29},"20",{"key":27,"text":75,"correct":22},"30",{"key":31,"text":77,"correct":29},"40",{"id":79,"libraryId":5,"type":55,"typeLabel":56,"stem":80,"options":81,"answer":27,"analysis":37},937200,"消防用电设备供电线路当线路暗敷设时，要对所穿金属导管或难燃性刚性塑料导管进行保护，并要敷设在不燃烧结构内，保护层厚度不要小于（ ）mm。",[82,83,84,85],{"key":20,"text":71,"correct":29},{"key":24,"text":73,"correct":29},{"key":27,"text":75,"correct":22},{"key":31,"text":77,"correct":29},{"id":87,"libraryId":5,"type":55,"typeLabel":56,"stem":88,"options":89,"answer":31,"analysis":37},937201,"消防电源在火灾时要持续为消防设备供电，为防止火灾通过消防用电设备供电线路传输，应对消防用电设备供电线路采取防火封堵措施。下列情况不属于应采取防火封堵措施的是（ ）。",[90,92,94,96],{"key":20,"text":91,"correct":29},"穿越不同的防火分区",{"key":24,"text":93,"correct":29},"沿竖井垂直敷设穿越楼板处",{"key":27,"text":95,"correct":29},"管线进出竖井处",{"key":31,"text":97,"correct":22},"消防泵房",{"id":99,"libraryId":5,"type":55,"typeLabel":56,"stem":100,"options":101,"answer":24,"analysis":37},937202,"防火防爆措施是综合性的措施，包括选用合理的电气设备，保持必要的防火间距，电气设备正常运行并有良好的通风，采用耐火设施，有完善的继电保护装置等技术措施。平面布置中，室外变、配电装置距堆场、可燃液体储罐和甲、乙类厂房库房不应小于（ ）m。",[102,104,106,108],{"key":20,"text":103,"correct":29},"15",{"key":24,"text":105,"correct":22},"25",{"key":27,"text":107,"correct":29},"35",{"key":31,"text":109,"correct":29},"45",{"id":111,"libraryId":5,"type":55,"typeLabel":56,"stem":112,"options":113,"answer":27,"analysis":37},937203,"消防用电设备平面布置的防火检查中，总油量为600kg以上充油设备，应安装在（ ）。",[114,116,118,120],{"key":20,"text":115,"correct":29},"两侧有隔板的间隔内",{"key":24,"text":117,"correct":29},"防爆隔墙的间隔内",{"key":27,"text":119,"correct":22},"单独的防爆间隔内",{"key":31,"text":121,"correct":29},"-侧有隔板的间隔内",{"id":123,"libraryId":5,"type":55,"typeLabel":56,"stem":124,"options":125,"answer":27,"analysis":37},937204,"变、配电装置过电流保护防火措施中，保证防护电器有效动作的电流不应大于回路载流量的（ ）倍。",[126,128,130,132],{"key":20,"text":127,"correct":29},"1.35",{"key":24,"text":129,"correct":29},"1.40",{"key":27,"text":131,"correct":22},"1.45",{"key":31,"text":133,"correct":29},"1.50",{"id":135,"libraryId":5,"type":55,"typeLabel":56,"stem":136,"options":137,"answer":20,"analysis":37},937205,"建筑物内常用的电气设备和装置包括变、配电装置以及安装在装置中的低压配电和控制电器。其中低压配电和控制电器相间绝缘电阻不应小于（ ）MΩ。",[138,140,141,142],{"key":20,"text":139,"correct":22},"5",{"key":24,"text":71,"correct":29},{"key":27,"text":103,"correct":29},{"key":31,"text":73,"correct":29},{"id":144,"libraryId":5,"type":55,"typeLabel":56,"stem":145,"options":146,"answer":20,"analysis":37},937206,"电气防火要求及技术措施中规定节日彩灯连接线路应采用绝缘铜导线，导线截面积应满足载流量要求，且不应小于（ ）mm2，灯头线不应小于1.0mm2。",[147,149,151,153],{"key":20,"text":148,"correct":22},"2.5",{"key":24,"text":150,"correct":29},"2.0",{"key":27,"text":152,"correct":29},"1.5",{"key":31,"text":154,"correct":29},"1.0",{"id":156,"libraryId":5,"type":55,"typeLabel":56,"stem":157,"options":158,"answer":24,"analysis":37},937207,"电动机应安装在牢固的机座上，机座周围应有适当的通道，与其他低压带电体、可燃物之间的距离不应小于（ ）m，并应保持干燥清洁。",[159,161,162,163],{"key":20,"text":160,"correct":29},"0.5",{"key":24,"text":154,"correct":22},{"key":27,"text":152,"correct":29},{"key":31,"text":150,"correct":29},{"id":165,"libraryId":5,"type":55,"typeLabel":56,"stem":166,"options":167,"answer":27,"analysis":37},937208,"低于3kW以下可移动式电热器应放在不燃材料制作的工作台上，与周围可燃物应保持（ ）m以上的距离；电热器应采用专用插座，引出线应采用石棉、瓷管等耐高温绝缘套管保护。",[168,170,172,174],{"key":20,"text":169,"correct":29},"0.1",{"key":24,"text":171,"correct":29},"0.2",{"key":27,"text":173,"correct":22},"0.3",{"key":31,"text":175,"correct":29},"0.4",{"id":177,"libraryId":5,"type":55,"typeLabel":56,"stem":178,"options":179,"answer":24,"analysis":37},937209,"下列有关安全使用家用电器的说法中，错误的是（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":29},"电冰箱及电视机等电器不要短时间内连续切断、接通电源",{"key":24,"text":183,"correct":22},"为节约空间，可以在电冰箱后面塞放可燃物",{"key":27,"text":185,"correct":29},"室外天线或共用天线的避雷器要有良好的接地，雷雨天气时尽量不要使用室外天线",{"key":31,"text":187,"correct":29},"电热毯第一次使用或长期搁置后再使用，应在有人监视的情况下先通电一段时间",{"id":189,"libraryId":5,"type":55,"typeLabel":56,"stem":190,"options":191,"answer":31,"analysis":37},937210,"消防控制室、消防水泵房、防烟和排烟风机房的消防用电设备及（ ）等的供电设备，应在其配电线路的最末一级配电箱处设置自动切换装置。",[192,194,196,198],{"key":20,"text":193,"correct":29},"消防应急照明",{"key":24,"text":195,"correct":29},"疏散指示系统",{"key":27,"text":197,"correct":29},"消防备用照明",{"key":31,"text":199,"correct":22},"消防电梯",{"id":201,"libraryId":5,"type":55,"typeLabel":56,"stem":202,"options":203,"answer":31,"analysis":37},937211,"下列关于变、配电装置防火措施的检查的描述中，不正确的是（ ）。",[204,206,208,210],{"key":20,"text":205,"correct":29},"变压器应设置短路保护装置，发生事故时能及时切断电源",{"key":24,"text":207,"correct":29},"回路内应装设断路器、熔断器之类的过电流防护电器来防范电气过载引起的灾害",{"key":27,"text":209,"correct":29},"回路内应设置短路防护电器",{"key":31,"text":211,"correct":22},"剩余电流保护装置的漏电、过载和短路保护特性均由制造厂调整好，用户可自行调节",{"id":213,"libraryId":5,"type":55,"typeLabel":56,"stem":214,"options":215,"answer":20,"analysis":37},937212,"下列有关低压配电和控制电器防火措施的检查，正确的是（ ）。",[216,218,220,222],{"key":20,"text":217,"correct":22},"同一端子上导线连接不应多于2根，且2根导线线径相同，防松垫圈等部件齐全",{"key":24,"text":219,"correct":29},"刀开关应采用电阻率和抗压强度高的材料制造触头",{"key":27,"text":221,"correct":29},"定期检查启动器触头表面状况，若发现触头表面粗糙，应以砂纸打磨",{"key":31,"text":223,"correct":29},"由于控制继电器的动作十分频繁，因此必须做到每月至少检修三次",{"id":225,"libraryId":5,"type":55,"typeLabel":56,"stem":226,"options":227,"answer":31,"analysis":37},937213,"下列有关说法不正确的是（ ）。",[228,230,232,234],{"key":20,"text":229,"correct":29},"电动机应安装在牢固的机座上，与其他低压带电体、可燃物之间的距离不应小于1.0m",{"key":24,"text":231,"correct":29},"超过3kW的固定式电热器具应采用单独回路供电",{"key":27,"text":233,"correct":29},"空调器具不应安装在可燃结构上，其设备与周围可燃物的距离不应小于0.3m",{"key":31,"text":235,"correct":22},"电热器具周围1m以内不应放置可燃物",{"id":237,"libraryId":5,"type":55,"typeLabel":56,"stem":238,"options":239,"answer":24,"analysis":37},937214,"消防配电线路在暗敷时，应穿管并应敷设在不燃性结构内且保护层厚度不应小于（ ）mm。",[240,241,242,243],{"key":20,"text":105,"correct":29},{"key":24,"text":75,"correct":22},{"key":27,"text":107,"correct":29},{"key":31,"text":77,"correct":29},{"id":245,"libraryId":5,"type":55,"typeLabel":56,"stem":246,"options":247,"answer":31,"analysis":37},937215,"使用燃烧等级为非A级电缆的隧道（沟），在封堵完成后，孔洞两侧电缆涂刷防火涂料长度不应小于（ ）m，干涂层厚度不小于1mm。",[248,249,250,252],{"key":20,"text":173,"correct":29},{"key":24,"text":160,"correct":29},{"key":27,"text":251,"correct":29},"0.8",{"key":31,"text":253,"correct":22},"1",{"id":255,"libraryId":5,"type":55,"typeLabel":56,"stem":256,"options":257,"answer":20,"analysis":37},937216,"电气线路中设置的过电流防护电器的有效动作电流不应（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"大于回路载流量的1.45倍",{"key":24,"text":261,"correct":29},"小于回路载流量的1.45倍",{"key":27,"text":263,"correct":29},"大于回路的计算负载电流",{"key":31,"text":265,"correct":29},"小于回路的允许持续载流量的1.5倍",{"id":267,"libraryId":5,"type":55,"typeLabel":56,"stem":268,"options":269,"answer":20,"analysis":37},937217,"电器相间绝缘电阻不应小于（ ）MΩ。",[270,271,272,273],{"key":20,"text":139,"correct":22},{"key":24,"text":71,"correct":29},{"key":27,"text":73,"correct":29},{"key":31,"text":75,"correct":29},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":286,"analysis":37},937218,"（ ）的消防用电设备及消防电梯等的供电设备，应在其配电线路的最末一级配电箱处设置自动切换装置。",[278,280,282,284,285],{"key":20,"text":279,"correct":22},"消防控制室",{"key":24,"text":281,"correct":22},"消防水泵房",{"key":27,"text":283,"correct":22},"防烟和排烟风机房",{"key":31,"text":193,"correct":29},{"key":34,"text":195,"correct":29},"ABC",{"id":288,"libraryId":5,"type":55,"typeLabel":56,"stem":289,"options":290,"answer":31,"analysis":37},937219,"消防用电设备的供电线路采用不同的电线电缆时，供电线路的敷设应满足相应的要求。当采用难燃性电缆或有机绝缘耐火电缆时，下列敷设方式不正确的是（ ）。",[291,293,295,297],{"key":20,"text":292,"correct":29},"在电气竖井内或电缆沟内敷设可不穿导管保护，但应采取与非消防用电缆隔离的措施",{"key":24,"text":294,"correct":29},"采用明敷设、吊顶内敷设或架空地板内敷设时，要穿金属导管或封闭式金属线槽保护，所穿金属导管或封闭式金属线槽要采用涂防火涂料等防火保护措施",{"key":27,"text":296,"correct":29},"当线路暗敷设时，要对所穿金属导管或难燃性刚性塑料导管进行保护，并要敷设在不燃烧结构内，保护层厚度应不小于30mm",{"key":31,"text":298,"correct":22},"可直接采用明敷设或在吊顶内敷设",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":313,"analysis":37},937220,"变、配电站（室）是工业企业的动力枢纽，电气设备较多，而且有些设备工作时会产生火花和高温，下列关于变、配电站（室）的平面布置，不正确的是（ ）。",[303,305,307,309,311],{"key":20,"text":304,"correct":29},"户内电压为1OkV以上、总油量为60kg以下的充油设备，可安装在两侧有隔板的间隔内",{"key":24,"text":306,"correct":29},"总油量为60-600kg者，应安装在有防爆隔墙的间隔内",{"key":27,"text":308,"correct":29},"总油量为600kg以上者，应安装在单独的防爆间隔内",{"key":31,"text":310,"correct":22},"10kV及以下的变、配电室不应设在爆炸危险环境的正上方、正下方或相邻房间内",{"key":34,"text":312,"correct":22},"变电室与各级爆炸危险环境毗连，最多只能有一面相连的墙与危险环境共用","DE",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":328,"analysis":37},937221,"电气线路防火措施包括预防电气线路短路、过负荷、接触电阻过大和屋内布线等措施。下列属于预防电气线路过负荷的措施的是（ ）。",[318,320,322,324,326],{"key":20,"text":319,"correct":22},"根据负载情况，选择合适的电线",{"key":24,"text":321,"correct":29},"铜、铝线相接，宜采用铜铝过渡接头，也可采用在铜线接头处搪锡",{"key":27,"text":323,"correct":22},"严禁滥用铜丝、铁丝代替熔断器的熔丝",{"key":31,"text":325,"correct":22},"不准乱拉电线和接入过多或功率过大的电气设备",{"key":34,"text":327,"correct":22},"严禁随意增加用电设备，尤其是大功率用电设备","ACDE",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":343,"analysis":37},937222,"节日彩灯的检查应符合（ ）的规定。",[333,335,337,339,341],{"key":20,"text":334,"correct":22},"建筑物顶部彩灯采用有防雨性能的专用灯具，灯罩要拧紧",{"key":24,"text":336,"correct":29},"彩灯连接线路应采用绝缘铜导线，导线截面面积应满足载流量要求，且不应小于5mm2",{"key":27,"text":338,"correct":22},"悬挂式彩灯应采用防水吊线灯头，灯头线与干线的连接应牢固并绝缘包扎紧密",{"key":31,"text":340,"correct":29},"彩灯供电线路应采用橡胶多股铜芯软导线，截面面积不应小于5.0mm2，垂直敷设时，对地面的距离不小于4.0m",{"key":34,"text":342,"correct":22},"彩灯的电源除统一控制外，每个支路应有单独控制开关和熔断器保护，导线的支持物应安装牢固","ACE",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":36,"analysis":37},937223,"下列关于电气防火措施的检查的说法，正确的是（ ）。",[348,350,351,353,355],{"key":20,"text":349,"correct":22},"电视机应保证良好的通风，若长期不用，尤其在雨季，要每隔一段时间使用几小时，用电视机自身发出的热量来驱散机内的潮气",{"key":24,"text":185,"correct":22},{"key":27,"text":352,"correct":29},"电热毯第一次使用或长期搁置后再使用，应在有人看管的情况下先通电半小时左右，检查是否安全",{"key":31,"text":354,"correct":22},"不要在沙发上、席梦思上和钢丝床上使用直线型电热线电热毯，这种电热毯只宜在木板床上使用",{"key":34,"text":356,"correct":22},"避免电热毯与人体接触，不能在电热毯上只铺一层床单，以防人体的揉搓使电热毯堆积打褶，导致局部过热或电线损坏，发生事故",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":286,"analysis":37},937224,"消防用电设备的供电线路采用不同的电线电缆时，供电线路的敷设应满足（ ）。",[361,363,365,366,368],{"key":20,"text":362,"correct":22},"当采用矿物绝缘电缆时，可直接采用明敷设或在吊顶内敷设",{"key":24,"text":364,"correct":22},"当采用难燃性电缆或有机绝缘耐火电缆时，在电气竖井内或电缆沟内敷设可不穿导管保护，但应采取与非消防用电缆隔离的措施",{"key":27,"text":294,"correct":22},{"key":31,"text":367,"correct":29},"当线路暗敷设时，要穿金属导管或难燃性刚性塑料导管保护，并要敷设在不燃结构内，保护层厚度不应小于50mm",{"key":34,"text":369,"correct":29},"当采用矿物绝缘电缆时，应穿金属管敷设",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":384,"analysis":37},937225,"下列关于各类配电保护装置的说法，正确的有（ ）。",[374,376,378,380,382],{"key":20,"text":375,"correct":22},"过电流防护电器的额定电流或整定电流不应小于回路的计算负载电流",{"key":24,"text":377,"correct":22},"过电流防护电器的额定电流或整定电流不应大于回路的允许持续载流量",{"key":27,"text":379,"correct":22},"短路防护电器的遮断容量不应小于其安装位置处的预期短路电流",{"key":31,"text":381,"correct":22},"被保护回路内任一点发生短路时，短路防护电器都应在被保护回路的导体温度上升到允许限值前切断电源",{"key":34,"text":383,"correct":29},"漏电保护器的过载和短路保护特性允许用户在允许范围内自行调节","ABCD",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":397,"analysis":37},937226,"下列属于预防电气线路接触电阻过大的措施是（ ）。",[389,390,392,394,395],{"key":20,"text":323,"correct":29},{"key":24,"text":391,"correct":22},"铜、铝线相接，采用铜铝过渡接头",{"key":27,"text":393,"correct":29},"在线路上安装断路器或熔断器",{"key":31,"text":319,"correct":29},{"key":34,"text":396,"correct":22},"通过较大电流的接头，采用油质或氧焊接头","BE",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":412,"analysis":37},937227,"下列关于插座的说法，正确的有（ ）。",[402,404,406,408,410],{"key":20,"text":403,"correct":22},"单相两孔插座，面对插座的右孔或上孔与相线连接，左孔或下孔与零线连接",{"key":24,"text":405,"correct":22},"三孔插座，面对插座的右孔与相线连接，左孔与零线连接",{"key":27,"text":407,"correct":22},"在潮湿场所中，插座应采用密封型并带保护地线触头的保护型插座，安装高度不低于1.5m",{"key":31,"text":409,"correct":29},"临时用电使用移动式插座，电源线要采用铜芯电缆或护套软线，串接不得超过两个",{"key":34,"text":411,"correct":22},"同一建筑物、构筑物的照明开关应采用同一系列的产品，开关的通断位置一致","ABCE",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":427,"analysis":37},937228,"对照明灯具的防火检查是电气防火的关键，下列关于照明灯具防火措施的说法，正确的有（ ）。",[417,419,421,423,425],{"key":20,"text":418,"correct":22},"卤素灯、60W以上的白炽灯等高温照明灯具不应设置在火灾危险性场所",{"key":24,"text":420,"correct":22},"超过60W的白炽灯、卤素灯、荧光高压汞灯等照明灯具（包括镇流器）不应安装在可燃材料和可燃构件上",{"key":27,"text":422,"correct":29},"嵌入顶棚内的灯具，灯头引线应采用柔性金属管保护，其保护长度不宜超过1.5m",{"key":31,"text":424,"correct":22},"霓虹灯与建筑物、构筑物表面距离不小于20mm",{"key":34,"text":426,"correct":29},"照明灯具上所装的灯泡，不应超过灯具的额定功率的1.15倍","ABD",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":439,"analysis":37},937229,"消防用电设备供电线路在电缆隧道时，须采取防火封堵措施的情况有（ ）。",[432,433,435,437,438],{"key":20,"text":91,"correct":22},{"key":24,"text":434,"correct":22},"穿越建筑物的外墙处",{"key":27,"text":436,"correct":22},"电缆隧道的隔墙处",{"key":31,"text":95,"correct":22},{"key":34,"text":93,"correct":22},"ABCDE",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":286,"analysis":37},937230,"在低压配电和控制电器装置中，预防电气线路短路的措施有（ ）。",[444,446,448,450,452],{"key":20,"text":445,"correct":22},"严格执行电气装置安装规程和技术管理规程",{"key":24,"text":447,"correct":22},"坚决禁止非电工人员安装、修理",{"key":27,"text":449,"correct":22},"在距地面2m高以内的电线，应用钢管或硬质塑料加以保护，以防绝缘遭受损坏",{"key":31,"text":451,"correct":29},"通过较大电流的接头，应采用油质或氧焊接头，在连接时加弹力片后拧紧",{"key":34,"text":321,"correct":29},{"id":454,"libraryId":5,"type":55,"typeLabel":56,"stem":455,"options":456,"answer":31,"analysis":37},937231,"防火封堵的检查要求正确的是（ ）。",[457,459,461,463],{"key":20,"text":458,"correct":29},"有人通过的电缆隧道，应在预留孔洞的下部采用膨胀型防火钢板进行加固",{"key":24,"text":460,"correct":29},"电缆竖井应采用膨胀型防火堵料",{"key":27,"text":462,"correct":29},"电气柜孔应采用矿棉板的防火封堵",{"key":31,"text":464,"correct":22},"防火封堵系统两侧电缆应采用电缆涂料",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":52,"analysis":37},937232,"在低压配电和控制电器装置中，预防电气线路过负荷的措施有（ ）。",[469,471,473,474,475],{"key":20,"text":470,"correct":29},"导线与导线、导线与电气设备的连接必须牢固可靠",{"key":24,"text":472,"correct":29},"要定期检查和检测接头，防止接触电阻增大，对重要的连接接头要加强监视",{"key":27,"text":323,"correct":22},{"key":31,"text":327,"correct":22},{"key":34,"text":325,"correct":22},{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":36,"analysis":37},937233,"消防用电设备供电线路在电缆隧道、电缆竖井、封闭式母线、线槽安装等处时，在下列情况应采取防火封堵措施（ ）。",[480,481,482,484,485],{"key":20,"text":91,"correct":22},{"key":24,"text":93,"correct":22},{"key":27,"text":483,"correct":29},"建筑内的所有孔洞",{"key":31,"text":434,"correct":22},{"key":34,"text":95,"correct":22},{"id":487,"libraryId":5,"type":55,"typeLabel":56,"stem":488,"options":489,"answer":24,"analysis":37},937234,"应安装在有防爆隔墙的间隔内的变、配电站（室）是（ ）。",[490,492,494,496],{"key":20,"text":491,"correct":29},"户内电压为10kV以上、总油量为60kg以下的充油设备",{"key":24,"text":493,"correct":22},"总油量为60-600kg者",{"key":27,"text":495,"correct":29},"总油量为600kg以上者",{"key":31,"text":497,"correct":29},"10kV及其以下者",{"id":499,"libraryId":5,"type":55,"typeLabel":56,"stem":500,"options":501,"answer":24,"analysis":37},937235,"库房照明宜采用（ ）采光。",[502,504,506,508],{"key":20,"text":503,"correct":29},"卤素灯",{"key":24,"text":505,"correct":22},"投光灯",{"key":27,"text":507,"correct":29},"荧光高压汞灯",{"key":31,"text":509,"correct":29},"回光灯",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":523,"analysis":37},937236,"预防电气线路过负荷的措施包括（ ）。",[514,516,518,520,521],{"key":20,"text":515,"correct":29},"宜用铜丝、铁丝代替熔断器的熔丝",{"key":24,"text":517,"correct":22},"严禁随意增加用电设备尤其是大功率用电设备",{"key":27,"text":519,"correct":22},"应根据线路负荷的变化及时更换适宜容量的导线",{"key":31,"text":451,"correct":29},{"key":34,"text":522,"correct":22},"可根据生产程序和需要，采取排列先后控制使用的方法，把用电时间调开","BCE",{"id":525,"libraryId":5,"type":55,"typeLabel":56,"stem":526,"options":527,"answer":31,"analysis":37},937237,"下列有关插座的安装方式不正确的是（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":29},"及实验室的插座安装高度距地面不小于0.3m",{"key":24,"text":531,"correct":29},"特殊场所暗装的插座安装高度距地面不小于0.15m",{"key":27,"text":533,"correct":29},"同一室内插座安装高度一致",{"key":31,"text":535,"correct":22},"非临时用电，可使用移动式插座",{"id":537,"libraryId":5,"type":55,"typeLabel":56,"stem":538,"options":539,"answer":27,"analysis":37},937238,"建筑物内景观照明灯具的导电部分对地电阻应大于（ ）MQ，",[540,541,542,544],{"key":20,"text":253,"correct":29},{"key":24,"text":152,"correct":29},{"key":27,"text":543,"correct":22},"2",{"key":31,"text":545,"correct":29},"3",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":558,"analysis":37},937239,"不应安装在可燃基座上的灯具有（ ）。",[550,552,554,555,557],{"key":20,"text":551,"correct":29},"荧光灯",{"key":24,"text":553,"correct":29},"白炽灯",{"key":27,"text":509,"correct":22},{"key":31,"text":556,"correct":22},"聚光灯",{"key":34,"text":505,"correct":29},"CD",{"id":560,"libraryId":5,"type":55,"typeLabel":56,"stem":561,"options":562,"answer":27,"analysis":37},937240,"当采用自备发电设备作为备用电源时，自备发电设备应设置（ ）启动装置。当采用自动启动方式时，应能保证在（ ）内供电。",[563,565,567,569],{"key":20,"text":564,"correct":29},"自动，3s",{"key":24,"text":566,"correct":29},"手动，10s",{"key":27,"text":568,"correct":22},"自动和手动，30s",{"key":31,"text":570,"correct":29},"自动或手动，60s",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":412,"analysis":37},937241,"下列部位应采取封堵措施的有（ ）。",[575,576,577,578,580],{"key":20,"text":91,"correct":22},{"key":24,"text":93,"correct":22},{"key":27,"text":95,"correct":22},{"key":31,"text":579,"correct":29},"穿越建筑物的隔墙处",{"key":34,"text":581,"correct":22},"电缆引至配电箱、柜或控制屏、台的开孔部位",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":286,"analysis":37},937242,"下列部位应使用防火灰泥加膨胀型防火堵料组合的阻火墙的是（ ）。",[586,588,590,592,594],{"key":20,"text":587,"correct":22},"电缆穿阻火墙",{"key":24,"text":589,"correct":22},"长距离电缆沟每隔50m处",{"key":27,"text":591,"correct":22},"电缆沟、电缆隧道由室外进入室内处",{"key":31,"text":593,"correct":29},"有人通过的电缆隧道",{"key":34,"text":595,"correct":29},"电气柜孔",{"id":597,"libraryId":5,"type":55,"typeLabel":56,"stem":598,"options":599,"answer":27,"analysis":37},937243,"当线路暗敷设时，要穿金属导管或难燃性刚性塑料导管保护，并要敷设在不燃烧结构内，保护层厚度不要小于（ ）mm。",[600,601,602,603],{"key":20,"text":71,"correct":29},{"key":24,"text":73,"correct":29},{"key":27,"text":75,"correct":22},{"key":31,"text":604,"correct":29},"50",{"id":606,"libraryId":5,"type":55,"typeLabel":56,"stem":607,"options":608,"answer":27,"analysis":37},937244,"采用无机堵料（防火灰泥或耐火砖）堆砌，其厚度不应小于（ ）mm。",[609,611,613,615],{"key":20,"text":610,"correct":29},"100",{"key":24,"text":612,"correct":29},"150",{"key":27,"text":614,"correct":22},"200",{"key":31,"text":616,"correct":29},"250",{"id":618,"libraryId":5,"type":55,"typeLabel":56,"stem":619,"options":620,"answer":20,"analysis":37},937245,"在（ ）中，应该采用保护接零方式。",[621,623,625,627],{"key":20,"text":622,"correct":22},"中性点有良好接地的低压配电系统",{"key":24,"text":624,"correct":29},"中性点不接地的低压配电网络",{"key":27,"text":626,"correct":29},"农村配电网络",{"key":31,"text":628,"correct":29},"高压电气设备",[630,633,636,639,642,645],{"id":55,"name":631,"category":7,"favorite":632},"领导干部任职前廉政法规知识测试题",92,{"id":634,"name":635,"category":7,"favorite":55},595,"建筑结构与设备",{"id":637,"name":638,"category":7,"favorite":55},715,"招标采购专业知识与法律法规",{"id":640,"name":641,"category":7,"favorite":55},848,"市政方向-通用基础",{"id":643,"name":644,"category":7,"favorite":8},534,"BIM工程师",{"id":646,"name":644,"category":7,"favorite":8},535]