[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-50":3},{"library":4,"page":9,"limit":9,"total":10,"questions":11,"related":644},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,50,2974,[12,33,45,57,69,81,93,105,117,129,141,153,165,177,195,210,224,234,249,261,273,288,300,312,326,338,353,365,373,385,395,405,417,429,441,453,465,477,489,501,513,525,537,549,561,573,585,600,615,629],{"id":13,"libraryId":5,"type":14,"typeLabel":15,"stem":16,"options":17,"answer":29,"analysis":32},937146,1,"单选题","某企业按照国家工程消防技术标准的要求，对已经投入使用的防烟排烟系统的组件、零部件等按照规定检查周期进行检查、测试。下列防烟排烟系统各部位的检查周期，说法错误的是（ ）。",[18,22,25,28],{"key":19,"text":20,"correct":21},"A","每季应对防烟、排烟风机进行一次功能检测启动试验",false,{"key":23,"text":24,"correct":21},"B","每半年应对系统阀门进行自动和手动启动试验",{"key":26,"text":27,"correct":21},"C","每年应对防烟、排烟系统进行联动试验",{"key":29,"text":30,"correct":31},"D","每月应对活动挡烟垂壁供电线路进行检查",true,"",{"id":34,"libraryId":5,"type":14,"typeLabel":15,"stem":35,"options":36,"answer":29,"analysis":32},937147,"下列不属于防烟排烟系统竣工验收时施工单位应提供的资料的是（ ）。",[37,39,41,43],{"key":19,"text":38,"correct":21},"竣工验收申请报告",{"key":23,"text":40,"correct":21},"施工图和竣工图",{"key":26,"text":42,"correct":21},"工程质量控制资料检查记录",{"key":29,"text":44,"correct":31},"主要零件说明书",{"id":46,"libraryId":5,"type":14,"typeLabel":15,"stem":47,"options":48,"answer":29,"analysis":32},937148,"在防烟排烟系统部件的安装，不符合规定的是（ ）。",[49,51,53,55],{"key":19,"text":50,"correct":21},"常闭送风口的手动驱动装置安装在距地面1.3m的墙面上",{"key":23,"text":52,"correct":21},"活动挡烟垂壁与建筑结构面的缝隙为50mm",{"key":26,"text":54,"correct":21},"活动挡烟垂壁的手动操作按钮距地面1.4m",{"key":29,"text":56,"correct":31},"屋顶排烟窗的手动开启机构安装在吊顶内",{"id":58,"libraryId":5,"type":14,"typeLabel":15,"stem":59,"options":60,"answer":19,"analysis":32},937149,"风管应按系统类别进行强度和严密性检验，检查数量应按风管系统类别和材质分别抽查，不应少于3件及（ ）㎡。",[61,63,65,67],{"key":19,"text":62,"correct":31},"15",{"key":23,"text":64,"correct":21},"2",{"key":26,"text":66,"correct":21},"1",{"key":29,"text":68,"correct":21},"3",{"id":70,"libraryId":5,"type":14,"typeLabel":15,"stem":71,"options":72,"answer":19,"analysis":32},937150,"下列关于防烟排烟系统组件的安装要求，不正确的是（ ）。",[73,75,77,79],{"key":19,"text":74,"correct":31},"排烟口距可燃物或可燃构件的距离不应小于0.5m",{"key":23,"text":76,"correct":21},"排烟窗的手动开启机构或按钮应固定安装在距楼地面1.3m~1.5m之间，并应便于操作、明显可见",{"key":26,"text":78,"correct":21},"活动挡烟垂壁的手动操作按钮应固定安装在距楼地面1.3m~1.5m之间便于操作、明显可见处",{"key":29,"text":80,"correct":21},"常闭送风口的手动驱动装置应固定安装在明显可见、距楼地面1.3m~1.5m之间便于操作的位置",{"id":82,"libraryId":5,"type":14,"typeLabel":15,"stem":83,"options":84,"answer":26,"analysis":32},937151,"对某建筑内设置的防烟排烟系统风机进行检查，下列检查结果中，不符合规范要求的是（ ）。",[85,87,89,91],{"key":19,"text":86,"correct":21},"送风机外壳至墙壁或其他设备的距离为650mm",{"key":23,"text":88,"correct":21},"手动开启送风机，风机能正常运转2.0h",{"key":26,"text":90,"correct":31},"送风机设在混凝土基础上，并设置有弹簧减振装置",{"key":29,"text":92,"correct":21},"送风机的进风口设置在排烟出口的下方，两者边缘的垂直距离8.0m",{"id":94,"libraryId":5,"type":14,"typeLabel":15,"stem":95,"options":96,"answer":19,"analysis":32},937152,"下列关于机械加压送风系统风速及余压的调试方法及要求，不正确的是（ ）。",[97,99,101,103],{"key":19,"text":98,"correct":31},"应选取送风系统末端所对应的送风最不利的两个连续楼层进行试验",{"key":23,"text":100,"correct":21},"封闭避难层（间）仅需选取本层",{"key":26,"text":102,"correct":21},"对楼梯间和前室的调试应单独分别进行，且互不影响",{"key":29,"text":104,"correct":21},"调试送风系统使对应楼层的楼梯间、前室及封闭避难层（间）的风压值及疏散门的门洞断面风速值与设计值的偏差不大于10%",{"id":106,"libraryId":5,"type":14,"typeLabel":15,"stem":107,"options":108,"answer":19,"analysis":32},937153,"根据《建筑防烟排烟系统技术标准》GB 51251，下列关于防烟分区的说法，不正确的是（ ）。",[109,111,113,115],{"key":19,"text":110,"correct":31},"公共建筑、工业建筑中的走道宽度不大于3m时，其防烟分区的长边长度不应大于60m",{"key":23,"text":112,"correct":21},"当空间净高大于9m时，防烟分区之间可不设置挡烟设施",{"key":26,"text":114,"correct":21},"设置排烟系统的场所或部位应采用挡烟垂壁、结构梁及隔墙等划分防烟分区，防烟分区不应跨越防火分区",{"key":29,"text":116,"correct":21},"当工业建筑采用自然排烟系统时，防烟分区长边长度符合规范要求的同时尚不应大于建筑内空间净高的8倍",{"id":118,"libraryId":5,"type":14,"typeLabel":15,"stem":119,"options":120,"answer":19,"analysis":32},937154,"防排烟系统的维护管理是系统正常完好、有效使用的基本保障，下列关于防烟排烟系统维护管理的说法，不正确的是（ ）。",[121,123,125,127],{"key":19,"text":122,"correct":31},"每周应对排烟风机的供电线路进行检查",{"key":23,"text":124,"correct":21},"每季度应对活动挡烟垂壁进行一次功能检测启动试验",{"key":26,"text":126,"correct":21},"每半年应对全部排烟防火阀进行自动和手动启动试验一次",{"key":29,"text":128,"correct":21},"每年应对全部防烟、排烟系统进行一次联动试验和性能检测",{"id":130,"libraryId":5,"type":14,"typeLabel":15,"stem":131,"options":132,"answer":26,"analysis":32},937155,"下列关于防排烟系统维护管理的说法，正确的是（ ）。",[133,135,137,139],{"key":19,"text":134,"correct":21},"每日检查系统电源的状态、电压",{"key":23,"text":136,"correct":21},"每季度检查室外进风口、排烟口是否通畅",{"key":26,"text":138,"correct":31},"每周检查风道及风口等部件的完好状况，有无异物变形",{"key":29,"text":140,"correct":21},"每日手动启动风机试运转",{"id":142,"libraryId":5,"type":14,"typeLabel":15,"stem":143,"options":144,"answer":26,"analysis":32},937156,"根据《建筑防烟排烟系统技术标准》GB 51251，关于防排烟系统维护管理的说法，正确的是（ ）。",[145,147,149,151],{"key":19,"text":146,"correct":21},"每月手动启动挡烟垂壁",{"key":23,"text":148,"correct":21},"每季度手动启动送风阀",{"key":26,"text":150,"correct":31},"每季度手动启动排烟窗",{"key":29,"text":152,"correct":21},"每月手动启动排烟风机",{"id":154,"libraryId":5,"type":14,"typeLabel":15,"stem":155,"options":156,"answer":29,"analysis":32},937157,"对活动的挡烟垂壁及其电动驱动装置和控制装置进行进场检查，按照规范要求，下列关于检查数量的说法正确的是（ ）。",[157,159,161,163],{"key":19,"text":158,"correct":21},"每批数量的10%，且不少于10件",{"key":23,"text":160,"correct":21},"每批数量的5%，且不少于10件",{"key":26,"text":162,"correct":21},"每批数量的5%，且不少于1件",{"key":29,"text":164,"correct":31},"每批数量的10%，且不少于1件",{"id":166,"libraryId":5,"type":14,"typeLabel":15,"stem":167,"options":168,"answer":19,"analysis":32},937158,"对某办公楼设置的防烟排烟系统进行验收，下列关于该工程是否合格的说法中，正确的是（ ）。",[169,171,173,175],{"key":19,"text":170,"correct":31},"挡烟垂壁不能手动开启属于A类不合格，该工程不合格",{"key":23,"text":172,"correct":21},"挡烟垂壁不能手动开启属于B类不合格，该工程不合格",{"key":26,"text":174,"correct":21},"挡烟垂壁不能手动开启属于C类不合格，该工程不合格",{"key":29,"text":176,"correct":21},"信息不全，无法判断",{"id":178,"libraryId":5,"type":179,"typeLabel":180,"stem":181,"options":182,"answer":194,"analysis":32},937159,2,"多选题","防烟排烟系统的构成包括（ ）。",[183,185,187,189,191],{"key":19,"text":184,"correct":21},"挡烟垂壁",{"key":23,"text":186,"correct":31},"风口",{"key":26,"text":188,"correct":31},"排烟窗",{"key":29,"text":190,"correct":31},"送风机",{"key":192,"text":193,"correct":31},"E","风道","BCDE",{"id":196,"libraryId":5,"type":179,"typeLabel":180,"stem":197,"options":198,"answer":209,"analysis":32},937160,"防烟排烟系统的安装主要包括风管、阀门组件和风机等主要设备的安装检测与调试。下列关于风管的安装与检测中，错误的是（ ）。",[199,201,203,205,207],{"key":19,"text":200,"correct":21},"现场风管的安装，不得缩小接口的有效截面",{"key":23,"text":202,"correct":21},"风管接口的连接应严密、牢固，垫片厚度不应小于3mm，不应凸入管内和法兰外",{"key":26,"text":204,"correct":31},"风管与风机连接若有转弯处，不宜加装导流叶片",{"key":29,"text":206,"correct":21},"风管穿越隔墙或楼板时，风管与隔墙之间的空隙，应采用水泥砂浆等不燃材料严密填塞",{"key":192,"text":208,"correct":31},"吊顶内的排烟管道应采用不燃材料隔热，并应与可燃物保持不小于100mm的距离","CE",{"id":211,"libraryId":5,"type":179,"typeLabel":180,"stem":212,"options":213,"answer":223,"analysis":32},937161,"可用于排烟风机的是（ ）。",[214,216,217,219,221],{"key":19,"text":215,"correct":31},"离心风机",{"key":23,"text":184,"correct":21},{"key":26,"text":218,"correct":31},"轴流风机",{"key":29,"text":220,"correct":31},"风机箱",{"key":192,"text":222,"correct":31},"屋顶式风机","ACDE",{"id":225,"libraryId":5,"type":179,"typeLabel":180,"stem":226,"options":227,"answer":233,"analysis":32},937162,"某工业建筑内设置机械排烟系统，下列关于机械排烟系统控制的说法，正确的有（ ）。 A.当火灾确认后，30s以内挡烟垂壁应开启到位 B.当火灾确认后，火灾自动报警系统应在30s内自动关闭与排烟无关的通风、空调系统C当火灾确认后，火灾自动报警系统应在15s内联动相应防烟分区的全部活动挡烟垂壁 C.当火灾确认后，火灾自动报警系统应在15s内联动开启相应防烟分区的全部排烟阀、排烟口、排烟风机和补风设施 D.自动排烟窗当采用与火灾自动报警系统自动启动时，自动排烟窗应在60s内或小于烟气充满储烟仓时间内开启完毕",[228,229,230,231,232],{"key":19,"text":19,"correct":21},{"key":23,"text":23,"correct":31},{"key":26,"text":26,"correct":31},{"key":29,"text":29,"correct":31},{"key":192,"text":192,"correct":21},"BCD",{"id":235,"libraryId":5,"type":179,"typeLabel":180,"stem":236,"options":237,"answer":248,"analysis":32},937163,"下列有关部件的安装要求正确的是（ ）。",[238,240,242,244,246],{"key":19,"text":239,"correct":31},"排烟口距可燃物或可燃构件的距离不应小于1.5m",{"key":23,"text":241,"correct":31},"常闭送风口、排烟阀（口）的手动驱动装置应固定安装在明显可见、距楼地面1.3-1.5m之间便于操作的位置",{"key":26,"text":243,"correct":31},"活动挡烟垂壁与建筑结构（柱或墙）面的缝隙不应大于60mm",{"key":29,"text":245,"correct":21},"由两块或两块以上的挡烟垂帘组成的连续性挡烟垂壁，各块之间不应有缝隙，搭接宽度不应小于150mm",{"key":192,"text":247,"correct":21},"活动挡烟垂壁的手动操作按钮应固定安装在便于操作、明显可见处距楼地面1.0-1.5m之间","ABC",{"id":250,"libraryId":5,"type":14,"typeLabel":15,"stem":251,"options":252,"answer":26,"analysis":32},937164,"防火分区隔墙两侧的防火阀，距墙端面不应大于（ ）mm。",[253,255,257,259],{"key":19,"text":254,"correct":21},"100",{"key":23,"text":256,"correct":21},"150",{"key":26,"text":258,"correct":31},"200",{"key":29,"text":260,"correct":21},"250",{"id":262,"libraryId":5,"type":14,"typeLabel":15,"stem":263,"options":264,"answer":29,"analysis":32},937165,"排烟风机与加压送风机的不同在于（ ）。",[265,267,269,271],{"key":19,"text":266,"correct":21},"排烟风机应保证在70℃的环境条件下能连续工作不少于60min",{"key":23,"text":268,"correct":21},"排烟风机应保证在70℃的环境条件下能连续工作不少于30min",{"key":26,"text":270,"correct":21},"排烟风机应保证在280℃的环境条件下能连续工作不少于60min",{"key":29,"text":272,"correct":31},"排烟风机应保证在280℃的环境条件下能连续工作不少于30min",{"id":274,"libraryId":5,"type":179,"typeLabel":180,"stem":275,"options":276,"answer":287,"analysis":32},937166,"风管与风机的连接宜采用（ ）连接。",[277,279,281,283,285],{"key":19,"text":278,"correct":21},"焊接",{"key":23,"text":280,"correct":31},"法兰",{"key":26,"text":282,"correct":21},"螺栓",{"key":29,"text":284,"correct":31},"不燃材料的柔性短管",{"key":192,"text":286,"correct":21},"承插","BD",{"id":289,"libraryId":5,"type":14,"typeLabel":15,"stem":290,"options":291,"answer":19,"analysis":32},937167,"防烟排烟系统的调试由（ ）负责进行。",[292,294,296,298],{"key":19,"text":293,"correct":31},"施工单位",{"key":23,"text":295,"correct":21},"建设单位",{"key":26,"text":297,"correct":21},"设计单位",{"key":29,"text":299,"correct":21},"监理单位",{"id":301,"libraryId":5,"type":14,"typeLabel":15,"stem":302,"options":303,"answer":23,"analysis":32},937168,"金属风管直径D≤630时，应采用（ ）螺栓连接。",[304,306,308,310],{"key":19,"text":305,"correct":21},"M4",{"key":23,"text":307,"correct":31},"M6",{"key":26,"text":309,"correct":21},"M8",{"key":29,"text":311,"correct":21},"M10",{"id":313,"libraryId":5,"type":179,"typeLabel":180,"stem":314,"options":315,"answer":223,"analysis":32},937169,"下列关于排烟系统设计的说法，正确的有（ ）。",[316,318,320,322,324],{"key":19,"text":317,"correct":31},"当采用自然排烟方式时，储烟仓的厚度不应小于空间净高的20%，且不应小于500mm",{"key":23,"text":319,"correct":21},"某室内空间净高为4m的办公建筑，一个防烟分区的排烟量应按不小于60?\u002F（h·㎡）计算，且取值不小于13000?\u002Fh",{"key":26,"text":321,"correct":31},"除中庭外，一个防烟分区的排烟量，当建筑空间净高小于等于6.0m时，其排烟量应经计算确定，且取值不小于15000?\u002Fh确定",{"key":29,"text":323,"correct":31},"当采用机械排烟方式时，储烟仓的厚度不应小于空间净高的10%，且不应小于500mm",{"key":192,"text":325,"correct":31},"排烟系统的设计风量不应小于该系统计算风量的1.2倍",{"id":327,"libraryId":5,"type":179,"typeLabel":180,"stem":328,"options":329,"answer":337,"analysis":32},937170,"防烟排烟系统包括（ ）。",[330,331,333,334,336],{"key":19,"text":186,"correct":31},{"key":23,"text":332,"correct":31},"风阀",{"key":26,"text":188,"correct":31},{"key":29,"text":335,"correct":31},"风机",{"key":192,"text":193,"correct":31},"ABCDE",{"id":339,"libraryId":5,"type":179,"typeLabel":180,"stem":340,"options":341,"answer":352,"analysis":32},937171,"活动挡烟垂壁与建筑结构（柱或墙）面的缝隙的大小合理的是（ ）。",[342,344,346,348,350],{"key":19,"text":343,"correct":31},"40mm",{"key":23,"text":345,"correct":31},"45mm",{"key":26,"text":347,"correct":31},"50mm",{"key":29,"text":349,"correct":31},"60mm",{"key":192,"text":351,"correct":21},"65mm","ABCD",{"id":354,"libraryId":5,"type":14,"typeLabel":15,"stem":355,"options":356,"answer":26,"analysis":32},937172,"机械加压送风的防烟设施中，自垂百叶式加压送风口常用于（ ）。",[357,359,361,363],{"key":19,"text":358,"correct":21},"前室",{"key":23,"text":360,"correct":21},"合用前室",{"key":26,"text":362,"correct":31},"防烟楼梯间",{"key":29,"text":364,"correct":21},"地下室",{"id":366,"libraryId":5,"type":14,"typeLabel":15,"stem":367,"options":368,"answer":23,"analysis":32},937173,"常用的排烟管道采用镀锌钢板加工制作，厚度按高压系统要求，并应采取隔热防火措施或与可燃物保持不小于（ ）mm的距离。",[369,370,371,372],{"key":19,"text":254,"correct":21},{"key":23,"text":256,"correct":31},{"key":26,"text":258,"correct":21},{"key":29,"text":260,"correct":21},{"id":374,"libraryId":5,"type":14,"typeLabel":15,"stem":375,"options":376,"answer":29,"analysis":32},937174,"排烟防火阀的组成不包括（ ）。",[377,379,381,383],{"key":19,"text":378,"correct":21},"阀体",{"key":23,"text":380,"correct":21},"叶片",{"key":26,"text":382,"correct":21},"执行机构",{"key":29,"text":384,"correct":31},"热感元件",{"id":386,"libraryId":5,"type":14,"typeLabel":15,"stem":387,"options":388,"answer":29,"analysis":32},937175,"薄钢板法兰风管应采用（ ）连接。",[389,391,393,394],{"key":19,"text":390,"correct":21},"对焊",{"key":23,"text":392,"correct":21},"粘接",{"key":26,"text":286,"correct":21},{"key":29,"text":282,"correct":31},{"id":396,"libraryId":5,"type":14,"typeLabel":15,"stem":397,"options":398,"answer":23,"analysis":32},937176,"防烟排烟系统施工调试完成后，由（ ）组织进行竣工验收。",[399,400,401,403],{"key":19,"text":293,"correct":21},{"key":23,"text":295,"correct":31},{"key":26,"text":402,"correct":21},"消防部门",{"key":29,"text":404,"correct":21},"质量监督站",{"id":406,"libraryId":5,"type":14,"typeLabel":15,"stem":407,"options":408,"answer":26,"analysis":32},937177,"非金属风管的材料品种、规格、性能与厚度等应符合设计和现行国家产品标准的规定，下列非金属风管的制作和连接中不符合要求的是（ ）。",[409,411,413,415],{"key":19,"text":410,"correct":21},"法兰的规格符合规定，其螺栓孔的间距不得大于120mm",{"key":23,"text":412,"correct":21},"矩形风管法兰的四角处，应设有螺孔",{"key":26,"text":414,"correct":31},"采用套管连接时，套管厚度不做要求",{"key":29,"text":416,"correct":21},"无机玻璃钢风管的玻璃布，必须无碱或中碱，风管的表面不得出现泛卤或严重泛霜。",{"id":418,"libraryId":5,"type":14,"typeLabel":15,"stem":419,"options":420,"answer":26,"analysis":32},937178,"下列可以作为排烟金属风管的隔热层的是（ ）。",[421,423,425,427],{"key":19,"text":422,"correct":21},"20mm的矿棉",{"key":23,"text":424,"correct":21},"20mm的岩棉",{"key":26,"text":426,"correct":31},"40mm的硅酸铝",{"key":29,"text":428,"correct":21},"50mm的橡塑",{"id":430,"libraryId":5,"type":14,"typeLabel":15,"stem":431,"options":432,"answer":26,"analysis":32},937179,"风机的安装与检测要求风机外壳至墙壁或其他设备的距离不应小于（ ）mm。",[433,435,437,439],{"key":19,"text":434,"correct":21},"400",{"key":23,"text":436,"correct":21},"500",{"key":26,"text":438,"correct":31},"600",{"key":29,"text":440,"correct":21},"700",{"id":442,"libraryId":5,"type":14,"typeLabel":15,"stem":443,"options":444,"answer":26,"analysis":32},937180,"某大型综合楼有50层，设有机械加压送风系统。相关消防部门对机械防烟系统进行验收，下列验收方法及结果不符合要求的是（ ）。",[445,447,449,451],{"key":19,"text":446,"correct":21},"选取送风最不利的三个连续楼层模拟起火层及其上下层",{"key":23,"text":448,"correct":21},"避难层（间）仅选取本层",{"key":26,"text":450,"correct":31},"防烟楼梯间和前室的测试可同时进行",{"key":29,"text":452,"correct":21},"楼梯间与走道之间的压差为40Pa",{"id":454,"libraryId":5,"type":14,"typeLabel":15,"stem":455,"options":456,"answer":23,"analysis":32},937181,"某消防检测机构对安装有防烟排烟系统的某银行大楼进行联动调试，以下说法中错误的是（ ）。",[457,459,461,463],{"key":19,"text":458,"correct":21},"调试人员打开任何一个常闭排烟阀（口），排烟风机均能联动启动",{"key":23,"text":460,"correct":31},"当火灾报警后，机械排烟系统应当能启动所有联动部位的排烟阀（口），并且状态信号应当反馈到消防控制室内",{"key":26,"text":462,"correct":21},"当火灾报警后，相关部位的排烟风机应当启动，其余部分的排烟风机不启动",{"key":29,"text":464,"correct":21},"有补风要求的机械排烟场所，当火灾报警后补风系统应启动",{"id":466,"libraryId":5,"type":14,"typeLabel":15,"stem":467,"options":468,"answer":29,"analysis":32},937182,"排烟窗的温控释放装置备用件应为（ ）。",[469,471,473,475],{"key":19,"text":470,"correct":21},"5%且不少于10只",{"key":23,"text":472,"correct":21},"5%且不少于5只",{"key":26,"text":474,"correct":21},"10%且不少于5只",{"key":29,"text":476,"correct":31},"10%且不少于10只",{"id":478,"libraryId":5,"type":14,"typeLabel":15,"stem":479,"options":480,"answer":19,"analysis":32},937183,"下列关于防排烟系统的说法，正确的是（ ）。",[481,483,485,487],{"key":19,"text":482,"correct":31},"系统柔性短管的制作材料必须为不燃材料",{"key":23,"text":484,"correct":21},"吊顶内的排烟管道与可燃物应保持不小于100mm的距离",{"key":26,"text":486,"correct":21},"防火分区隔墙两侧的排烟防火阀，距墙端面不应大于100mm",{"key":29,"text":488,"correct":21},"排烟口距可燃构件的距离不应小于1.0m",{"id":490,"libraryId":5,"type":14,"typeLabel":15,"stem":491,"options":492,"answer":29,"analysis":32},937184,"对某民用建筑内设置的防烟排烟系统进行检查，下列检查结果中，不符合规范要求的是（ ）。",[493,495,497,499],{"key":19,"text":494,"correct":21},"金属风管采用法兰连接，其螺栓孔的间距为140mm",{"key":23,"text":496,"correct":21},"排烟风管的隔热层采用厚度为42mm的不燃绝热材料",{"key":26,"text":498,"correct":21},"非金属风管采用法兰连接，其螺栓孔的间距为115mm",{"key":29,"text":500,"correct":31},"金属风管应以板材连接的密封为主，可辅以密封胶嵌缝或其他方法密封，密封面宜设在风管的负压侧",{"id":502,"libraryId":5,"type":14,"typeLabel":15,"stem":503,"options":504,"answer":23,"analysis":32},937185,"下列关于排烟防火阀的安装要求，不正确的是（ ）。",[505,507,509,511],{"key":19,"text":506,"correct":21},"阀门应顺气流方向关闭",{"key":23,"text":508,"correct":31},"防火分区隔墙两侧的排烟防火阀距墙端而不应大于150mm",{"key":26,"text":510,"correct":21},"应设独立的支、吊架",{"key":29,"text":512,"correct":21},"排烟防火阀安装完毕后应按各系统不小于30%的数量检查",{"id":514,"libraryId":5,"type":14,"typeLabel":15,"stem":515,"options":516,"answer":29,"analysis":32},937186,"下列关于防烟排烟系统调试的说法，不正确的是（ ）。",[517,519,521,523],{"key":19,"text":518,"correct":21},"当任何一个常闭送风口开启时，相应的送风机均应能联动启动",{"key":23,"text":520,"correct":21},"排烟防火阀在280℃时应自行关闭，并应连锁关闭排烟风机和补风机",{"key":26,"text":522,"correct":21},"有补风要求的机械排烟场所，当火灾确认后，补风系统应启动",{"key":29,"text":524,"correct":31},"当火灾自动报警探测器发出火警信号后，应在30s内启动与设计要求一致的送风口、送风机",{"id":526,"libraryId":5,"type":14,"typeLabel":15,"stem":527,"options":528,"answer":29,"analysis":32},937187,"排烟窗的温控释放装置、排烟防火阀的易熔片应有（ ）的备用件，且不少于（ ）只。",[529,531,533,535],{"key":19,"text":530,"correct":21},"1%,5",{"key":23,"text":532,"correct":21},"10%,5",{"key":26,"text":534,"correct":21},"1%,10",{"key":29,"text":536,"correct":31},"10%,10",{"id":538,"libraryId":5,"type":14,"typeLabel":15,"stem":539,"options":540,"answer":26,"analysis":32},937188,"下列关于防排烟系统维护管理的说法，不正确的是（ ）。",[541,543,545,547],{"key":19,"text":542,"correct":21},"每年系统应做联动试验",{"key":23,"text":544,"correct":21},"每半年应手动或启动启动排烟口",{"key":26,"text":546,"correct":31},"每月应检查双回路自动切换电源",{"key":29,"text":548,"correct":21},"每半年应手动或自动启动送风口",{"id":550,"libraryId":5,"type":14,"typeLabel":15,"stem":551,"options":552,"answer":23,"analysis":32},937189,"根据《建筑消防设施的维护管理》（GB 25201-2010）的相关规定，下列不属于防烟排烟系统巡查内容的是（ ）。",[553,555,557,559],{"key":19,"text":554,"correct":21},"排烟机房的环境",{"key":23,"text":556,"correct":31},"排烟管道的外观",{"key":26,"text":558,"correct":21},"排烟风机控制柜的工作状态",{"key":29,"text":560,"correct":21},"排烟风机的外观",{"id":562,"libraryId":5,"type":14,"typeLabel":15,"stem":563,"options":564,"answer":19,"analysis":32},937190,"消防设施现场检查结束后，根据各类消防设施的施工及验收规范确定的工程施工质量缺陷类别，按照规范要求对各类消防设施的施工质量作出验收判定结论，下列关于防烟排烟系统验收标准的说法，正确的是（ ）。",[565,567,569,571],{"key":19,"text":566,"correct":31},"当A=0，B≤2，且B+C≤6时，竣工验收判定为合格，否则，竣工验收判定为不合格",{"key":23,"text":568,"correct":21},"当系统验收项有A类不合格时，系统验收判定为不合格",{"key":26,"text":570,"correct":21},"当A=0，B≤2，且B+C≤检查项的5%时，竣工验收判定为合格，否则，竣工验收判定为不合格",{"key":29,"text":572,"correct":21},"当系统验收项有任一项为不合格时，系统验收判定为不合格",{"id":574,"libraryId":5,"type":14,"typeLabel":15,"stem":575,"options":576,"answer":29,"analysis":32},937191,"可开启外窗应方便直接开启，设置在高处不便于直接开启的可开启外窗应在距地面高度为（ ）m的位置设置手动开启装置。",[577,579,581,583],{"key":19,"text":578,"correct":21},"0.9-1.3",{"key":23,"text":580,"correct":21},"1.1-1.2",{"key":26,"text":582,"correct":21},"1.6-1.7",{"key":29,"text":584,"correct":31},"1.3-1.5",{"id":586,"libraryId":5,"type":179,"typeLabel":180,"stem":587,"options":588,"answer":599,"analysis":32},937192,"下列有关金属风管的制作与连接正确的是（ ）。",[589,591,593,595,597],{"key":19,"text":590,"correct":31},"风管连接时，其螺栓孔的间距不得大于150mm",{"key":23,"text":592,"correct":31},"矩形风管法兰四角处应设有螺孔",{"key":26,"text":594,"correct":21},"板材不应采用咬口连接或铆接",{"key":29,"text":596,"correct":21},"镀锌钢板及含有复合保护层的钢板可采用焊接",{"key":192,"text":598,"correct":31},"风管应以板材连接的密封为主，密封面宜设在风管的正压侧","ABE",{"id":601,"libraryId":5,"type":179,"typeLabel":180,"stem":602,"options":603,"answer":614,"analysis":32},937193,"以下关于防排烟系统工程质量验收判定的说法，正确的是（ ）。",[604,606,608,610,612],{"key":19,"text":605,"correct":31},"系统设备，部件的型号、规格与设计不符，定为A类不合格",{"key":23,"text":607,"correct":21},"无出厂质量合格证明文件，定为B类不合格",{"key":26,"text":609,"correct":21},"系统验收性能参数不符合要求，定为B类不合格",{"key":29,"text":611,"correct":31},"竣工验收资料不完整，定为B类不合格",{"key":192,"text":613,"correct":31},"当A=0，B=2，C=4，可判定为合格","ADE",{"id":616,"libraryId":5,"type":179,"typeLabel":180,"stem":617,"options":618,"answer":599,"analysis":32},937194,"自然通风及自然排烟设施验收主要包括（ ）。",[619,621,623,625,627],{"key":19,"text":620,"correct":31},"楼梯间、前室、消防电梯前室可开启外窗的布置方式和面积",{"key":23,"text":622,"correct":31},"避难层（间）可开启外窗的布置方式和面积",{"key":26,"text":624,"correct":21},"挡烟垂壁开启到位的时间",{"key":29,"text":626,"correct":21},"排烟阀的开启",{"key":192,"text":628,"correct":31},"排烟窗的布置方式和面积",{"id":630,"libraryId":5,"type":179,"typeLabel":180,"stem":631,"options":632,"answer":643,"analysis":32},937195,"当使用移动式插座时，下列措施正确的是（ ）。",[633,635,637,639,641],{"key":19,"text":634,"correct":31},"电源线要采用铜芯电缆或护套软线",{"key":23,"text":636,"correct":31},"具有保护接地线（PE线）",{"key":26,"text":638,"correct":31},"禁止放置在可燃物上",{"key":29,"text":640,"correct":21},"在一定范围内，可以串接使用",{"key":192,"text":642,"correct":31},"严禁超容量使用","ABCE",[645,648,651,654,657,660],{"id":14,"name":646,"category":7,"favorite":647},"领导干部任职前廉政法规知识测试题",92,{"id":649,"name":650,"category":7,"favorite":14},595,"建筑结构与设备",{"id":652,"name":653,"category":7,"favorite":14},715,"招标采购专业知识与法律法规",{"id":655,"name":656,"category":7,"favorite":14},848,"市政方向-通用基础",{"id":658,"name":659,"category":7,"favorite":8},534,"BIM工程师",{"id":661,"name":659,"category":7,"favorite":8},535]