[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":646},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,5,50,2974,[13,34,52,64,76,91,103,115,127,142,154,166,180,195,207,219,231,246,258,270,282,294,306,318,330,342,354,366,378,390,404,416,428,440,452,464,472,484,496,508,523,531,543,558,573,585,600,610,622,634],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},934875,1,"单选题","(2017年真题) 对某高层宾馆建筑的室内装修工程进行现场检查,下列结果中,不符合现行国家消防技术标准的是(??)",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","客房吊顶采用轻钢龙骨石膏板(A级)",false,{"key":24,"text":25,"correct":22},"B","窗帘采用普通布艺材料制作(B2级)",{"key":27,"text":28,"correct":22},"C","疏散走道两侧的墙面采用大理石(A级)",{"key":30,"text":31,"correct":32},"D","防火门的表面贴了彩色阻燃人造板,门框和门的规格尺寸未减小(B1级)",true,"",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":51,"analysis":33},934876,2,"多选题","(2017年真题) 某施工单位对学校报告厅进行内部装饰， 其中吊顶采用轻钢龙骨纸面石膏板， 地面铺设地毯， 墙面采用不同装修材料进行分层装修。 关于该报告厅内部装饰的说法， 正确的有（）",[40,42,44,46,48],{"key":20,"text":41,"correct":32},"纸面石膏板安装在钢龙骨上时， 可做为A级材料使用",{"key":24,"text":43,"correct":32},"复合型装修材料应交专业检测机构进行整体测试确定燃烧性能等级",{"key":27,"text":45,"correct":22},"墙面分层装修材料除表面层的燃烧性能等级应符合规范要求外，其余各层的燃烧性能等级可不限",{"key":30,"text":47,"correct":32},"地毯应使用阻燃制品， 并应加贴阻燃标识",{"key":49,"text":50,"correct":32},"E","进入施工现场的装修材料应按要求填写进场验收记录","ABDE",{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":30,"analysis":33},934877,"(2018年真题) 对某建筑高度为78m的住宅建筑的外墙保温与装饰工程进行防火检查，该工程的下列做法中，不符合现行国家标准要求的是()",[56,58,60,62],{"key":20,"text":57,"correct":22},"外墙外保温系统与装饰层之间的空腔采用防火封堵材料在每层楼板处封堵",{"key":24,"text":59,"correct":22},"外墙外保温系统与基层墙体之间的空腔采用防火封堵材料在每层楼板处封堵",{"key":27,"text":61,"correct":22},"外墙外保温系统采用玻璃棉作保温材料",{"key":30,"text":63,"correct":32},"外墙的装饰材料选用燃烧性能为B1级的轻质复合墙板",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":20,"analysis":33},934878,"(2016年真题) 对建筑内部装修防火工程进行验收时，应对电气设备及灯具的设置进行检查。在对某建筑的内装修工程检查时，下列检查结果中，不符合现行国家消防技术标准规定的是（??）",[68,70,72,74],{"key":20,"text":69,"correct":32},"插座安装在木质装修材料上",{"key":24,"text":71,"correct":22},"配电箱的壳体和底板采用金属材料制作，安装在轻钢龙骨纸面石膏板墙上",{"key":27,"text":73,"correct":22},"吊顶内的电线采用金属管保护",{"key":30,"text":75,"correct":22},"开关安装在水泥板隔墙上",{"id":77,"libraryId":5,"type":36,"typeLabel":37,"stem":78,"options":79,"answer":90,"analysis":33},934879,"(2016年真题) 对建筑内部精修工程进行防火检查时，应注意检查装修施工单位有关规定的情况。根据现行国家消防技术标准，下列规定中，应由施工单位遵守的有（??）",[80,82,84,86,88],{"key":20,"text":81,"correct":22},"施工现场应具备相应的工程质量检测制度",{"key":24,"text":83,"correct":32},"防火装修材料进入施工现场后应对材料进行见证取样检验",{"key":27,"text":85,"correct":32},"材料进场时应检查精装修材料的燃烧性能，并填写进场检查记录",{"key":30,"text":87,"correct":32},"装修施工过程中，应分阶段对所选用防火装修材料进行抽样检验",{"key":49,"text":89,"correct":32},"内部装修不应影响消防设施的使用功能","BCDE",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":30,"analysis":33},934880,"(2017年真题)对某多层住宅建筑外墙保温及装饰工程施工现场进行检查发现该建筑外保温材料按设计采用了燃烧性能为B1级的保温材料。下列外保温系统施工做法中,错误的是（ ）",[95,97,99,101],{"key":20,"text":96,"correct":22},"外保温系统表面防护层使用不燃材料",{"key":24,"text":98,"correct":22},"在外保温系统中毎层沿楼板位置设置不燃材料制作的水平防火隔离带",{"key":27,"text":100,"correct":22},"外保温系统防护层将保温材料完全包覆的防护层厚度为15mm",{"key":30,"text":102,"correct":32},"外保温系统中设置的水平防火隔离带的高度为200mm",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":20,"analysis":33},934881,"(2017年真题)关于基层墙体与装饰层之间无空间的建筑外墙体外保温系统的做法中，不符合现行国家消防技术标准的是（??）",[107,109,111,113],{"key":20,"text":108,"correct":32},"建筑高度为18m的大学教学楼， 保温系统采用燃烧性能为B1l级的保温材料",{"key":24,"text":110,"correct":22},"建筑高度为54m的底层设置商业网点的住宅， 保温系统采用燃烧性能为B1级的保温材料",{"key":27,"text":112,"correct":22},"建筑高度50m的办公楼， 保温系统采用燃烧性能为B1级的保温材料",{"key":30,"text":114,"correct":22},"建筑高度24m的办公楼， 保温系统采用燃烧性能为B2级的保温材料",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":27,"analysis":33},934882,"(2018年真题)某建筑高度为26m的办公楼，设有集中空气调节系统和自动喷水灭火系统，其室内装修的下列做法中，不符合现行国家标准要求的是( )",[119,121,123,125],{"key":20,"text":120,"correct":22},"会客厅采用经阻燃处理的布艺做灯饰",{"key":24,"text":122,"correct":22},"将开关和接线盒安装在难燃胶合板上",{"key":27,"text":124,"correct":32},"会议室顶棚采用岩棉装饰板吊顶",{"key":30,"text":126,"correct":22},"走道顶棚采用金属龙骨纸面石膏板吊顶",{"id":128,"libraryId":5,"type":36,"typeLabel":37,"stem":129,"options":130,"answer":141,"analysis":33},934883,"(2018年真题)某建筑高度为98m的多功能建筑，在进行室内装修工程施工时，不符合现行国家标准要求的做法有( )。",[131,133,135,137,139],{"key":20,"text":132,"correct":32},"对现场阻燃处理后的木质材料，每种取2m2检验燃烧性能",{"key":24,"text":134,"correct":32},"对木质材料表面进行防火涂料处理时，均匀涂刷一次防火涂料",{"key":27,"text":136,"correct":22},"对B1级木质材料进场进行见证取样检验",{"key":30,"text":138,"correct":22},"对木质材料进行阻燃处理时，将木质材料的含水率控制在10%以下",{"key":49,"text":140,"correct":32},"对木质材料表面涂刷防火涂料的用量为450g\u002F㎡","ABE",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},934884,"(2018年真题)外保温系统与基层墙体、装饰层之间无空腔时，建筑外墙外保温系统的下列做法中，不符合现行国家标准要求的是( )",[146,148,150,152],{"key":20,"text":147,"correct":22},"建筑高度为48m的办公建筑采用B1级外保温材料",{"key":24,"text":149,"correct":22},"建筑高度为23.9m的办公建筑采用B2级外保温材料",{"key":27,"text":151,"correct":32},"建筑层数为3层的老年人照料设施采用B级外保温材料",{"key":30,"text":153,"correct":22},"建筑高度为26m的住宅建筑采用B2级外保温材料",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":30,"analysis":33},934885,"(2016年真题)在对建筑外墙装饰材料进行防火检查时，发现的下列做法中，不符合现行国家消防技术标准规定的是（??）",[158,160,162,164],{"key":20,"text":159,"correct":22},"3层综合建筑，外墙的装饰层采用防火塑料装饰板",{"key":24,"text":161,"correct":22},"25层住宅楼，外墙的装修层采用大理石",{"key":27,"text":163,"correct":22},"建筑高度48M的医院，外墙的装饰层采用多彩涂料",{"key":30,"text":165,"correct":32},"建筑高度55M的教学楼，外墙的装饰层采用铝塑板",{"id":167,"libraryId":5,"type":36,"typeLabel":37,"stem":168,"options":169,"answer":141,"analysis":33},934886,"（2020年真题）某高层酒店设有火灾自动报警系统和火自动喷水灭火系统的，该建筑室内装修的下列做法中，不符合现行国家标准要求的有（ ）。",[170,172,174,176,178],{"key":20,"text":171,"correct":32},"消防控制室墙面采用防火塑料装饰板装修",{"key":24,"text":173,"correct":32},"厨房顶棚采用铝箔玻璃钢复合材料装修",{"key":27,"text":175,"correct":22},"地下一层的家具库房地面采用硬PVC塑料地板装修",{"key":30,"text":177,"correct":22},"空调机房吊顶采用硅酸钙板装修",{"key":49,"text":179,"correct":32},"配电室墙面采用矿棉板装修",{"id":181,"libraryId":5,"type":36,"typeLabel":37,"stem":182,"options":183,"answer":194,"analysis":33},934887,"（2020年真题）某建筑高度为36m、耐火等级为二级的商场，设有自动喷水灭火系统和火灾自动报警系统，该商场建筑外墙外保温和外墙装饰的下列做法中，不符合现行国家标准的有（ ）。",[184,186,188,190,192],{"key":20,"text":185,"correct":32},"选用燃烧性能为B1级的燃材料作为外墙外保温材料",{"key":24,"text":187,"correct":32},"电气线路穿金属管保护后直接敷设在燃烧性能为B1级的外保温材料中",{"key":27,"text":189,"correct":22},"选用燃烧性能为B1级的材料作为外墙装饰材料",{"key":30,"text":191,"correct":22},"选用燃烧性能为B1级的材料作为屋面外墙保温材料。",{"key":49,"text":193,"correct":22},"二层外墙外保温系统不燃材料防护层厚度为10mm","AB",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":20,"analysis":33},934888,"（2019年真题）根据现行国家技术标准《建筑消防设施的维护管理》(GB25201)，消防控制室设专人值班时，关于消防设施设置状态的说法，符合标准要求的是（）",[199,201,203,205],{"key":20,"text":200,"correct":32},"正常工作状态下，应将自动喷水灭火系统，防烟排烟系统和联动控制的用于防火分隔的防火卷帘设置在自动控制状态",{"key":24,"text":202,"correct":22},"正常工作状态下，可将防烟排烟系统设置在手动控制状态，发生火灾时立即将手动控制状态转换为自动控制状态",{"key":27,"text":204,"correct":22},"正常工作状态下，可将联动控制的用于防火分隔的防火卷帘设置在手动控制状态，发生火灾时立即将手动控制状态转换为自动控制状态",{"key":30,"text":206,"correct":22},"正常工作状态下，可将联动控制的用于防火分隔的防火门设置在手动控制状态，发生火灾时立即将手动控制状态转换为自动控制状态",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":30,"analysis":33},934889,"(2016年真题) 某五星级酒店设有消防控制中心，配备8名值班人员轮值，下列消防安全职责中，不属于消防控制中心值班人员职责的是（ ）",[211,213,215,217],{"key":20,"text":212,"correct":22},"填写消防控制室值班记录表",{"key":24,"text":214,"correct":22},"记录消防控制室室内消防设备的火警或故障情况",{"key":27,"text":216,"correct":22},"对火灾报警控制器进行日常检查",{"key":30,"text":218,"correct":32},"实施日常防火检查和巡查",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":20,"analysis":33},934890,"(2016年真题) 消防工程施工工地的进场检验含合法性检查，一致性检查及产品质量检查，某工地对消火栓进行检查，下列检查项目中，属于合法性检查的项目是（??）",[223,225,227,229],{"key":20,"text":224,"correct":32},"型式检验报告",{"key":24,"text":226,"correct":22},"抽样试验",{"key":27,"text":228,"correct":22},"型号规格",{"key":30,"text":230,"correct":22},"设计参数",{"id":232,"libraryId":5,"type":36,"typeLabel":37,"stem":233,"options":234,"answer":245,"analysis":33},934891,"(2016年真题) 某高层宾馆按照指定的消防应急预案，组织进行灭火和应急疏散演练。下列程序中，正确的有（??）",[235,237,239,241,243],{"key":20,"text":236,"correct":22},"确认火灾后，消防控制室值班人员先报告值班领导",{"key":24,"text":238,"correct":22},"接到火警后，立即通知保安人员进行确认",{"key":27,"text":240,"correct":32},"确认火灾后，消防控制室值班人员立即将火灾报警联动控制开关转入自动状态，同时打“119”报警",{"key":30,"text":242,"correct":32},"确认火灾后，通知宾馆内各层客人疏散",{"key":49,"text":244,"correct":32},"确认火灾后，组织宾馆专业消防对进行初级灭火","CDE",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},934892,"(2017年真题)消防控制室应保存建筑竣工图纸和与消防有关的纸质台账及电子资料，下列资料中，消防控制室可不予保存的是（??）。",[250,252,254,256],{"key":20,"text":251,"correct":32},"消防设施施工调试记录",{"key":24,"text":253,"correct":22},"消防组织机构图",{"key":27,"text":255,"correct":22},"消防重点部位位置图",{"key":30,"text":257,"correct":22},"消防安全培训记录",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":30,"analysis":33},934893,"(2018年真题)根据现行行业标准《建筑消防设施检测技术规程》（GA503），不属于消防设施检测项目的是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"电动排烟窗",{"key":24,"text":265,"correct":22},"电动防火阀",{"key":27,"text":267,"correct":22},"灭火器",{"key":30,"text":269,"correct":32},"消防救援窗口",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":33},934894,"(2018年真题)某大型城市综合体设有三个消防控制室，对消防控制室的下列检查结果中不符合现行国家标准《消防控制室通用技术要求》(GB25506)的是( )",[274,276,278,280],{"key":20,"text":275,"correct":22},"确定了主消防控制室和分消防控制室",{"key":24,"text":277,"correct":32},"分消防控制室之间的消防设备可以互相控制并传输、显示状态信息",{"key":27,"text":279,"correct":22},"主消防控制室可对系统内共用的消防设施进行控制，并显示其状态信息",{"key":30,"text":281,"correct":22},"主消防控制室可对分消防控制室内的消防设备及其控制的消防系统和设备进行控制",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":27,"analysis":33},934895,"(2017年真题) 下列设施中，不属于消防车取水用的设施是（）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"市政消火栓",{"key":24,"text":289,"correct":22},"消防水池取水口",{"key":27,"text":291,"correct":32},"水泵接合器",{"key":30,"text":293,"correct":22},"消防水鹤",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":20,"analysis":33},934896,"(2017年真题) 关于大型商业综合体消防设施施工前需要具备的基本条件的说法中，错误的是()。",[298,300,302,304],{"key":20,"text":299,"correct":32},"消防工程设计文件经建设单位批准",{"key":24,"text":301,"correct":22},"消防设施设备及材料有符合市场准入制度的有效证明及产品出厂合格证书",{"key":27,"text":303,"correct":22},"施工现场的水、电能够满足连续施工的要求",{"key":30,"text":305,"correct":22},"与消防设施相关的基础、预埋件和预置孔洞等符合设计要求",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":27,"analysis":33},934897,"(2015年真题) 消防设施档案应真实记录建筑消防设施的质量状况，从延续性要求及可追溯性要求出发，完整的档案内容应包括（）。",[310,312,314,316],{"key":20,"text":311,"correct":22},"消防设施平面布局、系统验收报告，维护保养记录",{"key":24,"text":313,"correct":22},"消防设施值班、巡查、检测、维护及记录",{"key":27,"text":315,"correct":32},"消防设施基本情况的各类文件资料，消防设施及相关人员动态管理的记录、资料",{"key":30,"text":317,"correct":22},"消防设施巡查记录以及消防控制室值班记录",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},934898,"(2017年真题) 下列设备和设施中，属于临时高压消防给水系统构成必需的设备设施是()。",[322,324,326,328],{"key":20,"text":323,"correct":22},"消防稳压泵",{"key":24,"text":325,"correct":32},"消防水泵",{"key":27,"text":327,"correct":22},"消防水池",{"key":30,"text":329,"correct":22},"市政管网",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":27,"analysis":33},934899,"(2016年真题)某单位在县城新建一个商场，依法取得了当地市公安支队出具的消防设计审核合格意见书。建设单位在施工过程中拟对原设计进行修改。该商场建设单位的下列做法中，正确的是（??）",[334,336,338,340],{"key":20,"text":335,"correct":22},"向当地县公安消防大队重新申请消防设计审核",{"key":24,"text":337,"correct":22},"将设计变更告知当地县公安消防大队",{"key":27,"text":339,"correct":32},"向当地市公安消防支队重新申请消防设计审核",{"key":30,"text":341,"correct":22},"将设计变更告知当地市公安消防支队",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":27,"analysis":33},934900,"(2016年真题) 某商场消防控制室先后接到地下室仓库内的2个感烟探测器，自动喷水灭火系统的水流指示器和报警阀压力开关等的动作信号，下列值班人员的工作程序中正确的是（??）",[346,348,350,352],{"key":20,"text":347,"correct":22},"组织扑救火灾",{"key":24,"text":349,"correct":22},"电话落实火情",{"key":27,"text":351,"correct":32},"打119电话报警",{"key":30,"text":353,"correct":22},"现场查看火情",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":24,"analysis":33},934901,"(2015年真题) 下列关于消防控制室内设置的消防控制室图形显示装置与火灾报警控制器、电气火灾监控设备、火灾报警传输设备等之间关系描述中，错误的是（）。",[358,360,362,364],{"key":20,"text":359,"correct":22},"火灾报警控制器可将所有信息传输至图形显示装置",{"key":24,"text":361,"correct":32},"通过操作图形显示装置，可控制消防水泵控制器的工作状态",{"key":27,"text":363,"correct":22},"电气火灾监控系统是由另一生产企业提供的产品，不能与火灾报警控制器连接的图形显示装置直接通信，所以连接了该企业提供的图形显示装置",{"key":30,"text":365,"correct":22},"火灾报警传输设备可直接连接图形显示装置",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":33},934902,"（2020年真题）某消防技术服务机构对某煤粉生产车间进行了防火检查。下列供暖系统防火防爆的检查结果中，不符合现行国家标准要求的是（ ）",[370,372,374,376],{"key":20,"text":371,"correct":32},"供暖管道用岩棉进行隔热",{"key":24,"text":373,"correct":22},"散热器表面的平均温度控制在85°℃",{"key":27,"text":375,"correct":22},"供暖管道表面温度为90°℃，与可燃物的间距为50mm",{"key":30,"text":377,"correct":22},"供暖设备的绝热材料为硅酸铝棉",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":20,"analysis":33},934903,"（2020年真题）某消防技术服务机构对某商场的消防设施进行了验收检测，各消防系统的不合格项目数量汇总如下： 根据现行国家标准，应判定为不合格的系统是()",[382,384,386,388],{"key":20,"text":383,"correct":32},"火灾自动报警系统",{"key":24,"text":385,"correct":22},"室内消火栓系统",{"key":27,"text":387,"correct":22},"自动喷水灭火系统",{"key":30,"text":389,"correct":22},"防烟排烟系统",{"id":391,"libraryId":5,"type":36,"typeLabel":37,"stem":392,"options":393,"answer":141,"analysis":33},934904,"(2015年真题) 管径大于DN50mm的消防管道水平架空安装时，应按规定设置防晃支架，下列相关要求中，正确的有（）。",[394,396,398,400,402],{"key":20,"text":395,"correct":32},"应在管道拐弯位置处设置一个防晃支架",{"key":24,"text":397,"correct":32},"应在管道三通位置处设置一个防晃支架",{"key":27,"text":399,"correct":22},"应在管道的始端设置一个防晃支架",{"key":30,"text":401,"correct":22},"应在管道的终端设置一个防晃支架",{"key":49,"text":403,"correct":32},"应在管道四通位置处设置一个防晃支架",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":20,"analysis":33},934905,"（2019年真题）某北方寒冷地区多层车库，设置的干式消火栓系统采用电动阀作为启闭装置，消防工程施工单位对该系统进行检查调试，下列检查调试结果中，不符合现行国家标准要求的是（）。",[408,410,412,414],{"key":20,"text":409,"correct":32},"干式消火栓系统电动阀的开启时间为45s",{"key":24,"text":411,"correct":22},"启闭装置后的管网为空管",{"key":27,"text":413,"correct":22},"系统管道的最高处设置了快速排气阀",{"key":30,"text":415,"correct":22},"消火栓系统电动阀启动后，最不利点消火栓4min后出水",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":30,"analysis":33},934906,"（2019年真题）某在建高层公共建筑，拟安装室内消火栓150套，消防工程施工单位对该建筑的消火栓进行现场检查。根据《消防给水及消火栓系统技术规范》(GB50974)。下列检查的做法和结果中，不符合标准要求的是（）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"旋转型消火栓的转动部件为铜质",{"key":24,"text":423,"correct":22},"消防软管卷盘的消防软管内径为19mm，长度30m",{"key":27,"text":425,"correct":22},"消防水枪的当量喷嘴直径为16mm",{"key":30,"text":427,"correct":32},"消火栓外观检查，抽检数为50套",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},934907,"（2019年真题）消防水泵安装的步骤包括:(1)复核消防水泵之间，以及消防水泵与墙或其他设备之间的间距，应满足安装运行和维护管理的要求:(2)将消防水泵固定于基础上，(3)安装消防水泵吸水管上的控制阀，根据现行国家标准《消防给水及消火栓系统技术规范》(GB50974)，安装顺序正确的是（）",[432,434,436,438],{"key":20,"text":433,"correct":32},"(1)(2)(3)",{"key":24,"text":435,"correct":22},"(2)(1)(3)",{"key":27,"text":437,"correct":22},"(1)(3)(2)",{"key":30,"text":439,"correct":22},"(2)(3)(1)",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":30,"analysis":33},934908,"（2019年真题）某高层建筑的消防给水系统维护保养项目包括，(1)对减压阀的流量和压力进行一次实验;(2)对消防水泵接合器的栓口及附件进行一次检查;(3)对柴油机消防水泵的将启动电池的电量进行检测，(4)对室外阀门井中，进水管上的控制阀门进行一次检查。根据现行国家标准《消防给水及消火栓系统技术规范》(GB50974)，上述4项维护保养项目中，属于季度保养项目的共有（）",[444,446,448,450],{"key":20,"text":445,"correct":22},"1项",{"key":24,"text":447,"correct":22},"3项",{"key":27,"text":449,"correct":22},"4项",{"key":30,"text":451,"correct":32},"2项",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":27,"analysis":33},934909,"（2019年真题）根据现行国家标准《消防给水及消火栓系统技术规范》(GB50974)，消防设施维护管理人员对消防水泵和稳压泵维护管理的下列做法中，符合规范要求的是（）",[456,458,460,462],{"key":20,"text":457,"correct":22},"每周对稳压泵的停泵启泵压力和启泵次数进行一次检查",{"key":24,"text":459,"correct":22},"每月模拟消防水泵自动控制的条件，自动启动消防水泵运转一次",{"key":27,"text":461,"correct":32},"每季度对消防水泵的出流量和压力进行一次实验",{"key":30,"text":463,"correct":22},"每季度对气压水罐的压力和有效容积进行一次检测",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":27,"analysis":33},934910,"（2019年真题）某消防工程视同单位在消防给水系统施工前制定了设备进场前的检验方案，其中稳压泵进场检验要求包括：（1）稳压泵的流量应满足设计要求，且不宜小于1L\u002Fs；（2）稳压泵的电机功率应满足水泵全性能曲线运行的要求；（3）泵及电机的外观表面不应有碰损；（4）泵与电机轴心的偏心不应大于2mm，根据现行国家标准《消防给水及消防栓系统技术规范》（GB50974），上述4项检验要求中，符合规范要求的共有（）",[468,469,470,471],{"key":20,"text":445,"correct":22},{"key":24,"text":451,"correct":22},{"key":27,"text":447,"correct":32},{"key":30,"text":449,"correct":22},{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":24,"analysis":33},934911,"（2019年真题） 某工业建筑的室外消火栓供水管网，管材采用钢丝网骨架塑料管，系统工作压力为0.4MPa。对该消火栓系统管道进行水压强度试验，试验压力最小不应小于（）。",[476,478,480,482],{"key":20,"text":477,"correct":22},"0.48MPa",{"key":24,"text":479,"correct":32},"0.8MPa",{"key":27,"text":481,"correct":22},"0.6MPa",{"key":30,"text":483,"correct":22},"0.9MPa",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":20,"analysis":33},934912,"（2019年真题）某超高层建筑高度为230m，塔楼功能为酒店、办公，裙房为商业。对该建筑消防设施进行验收检测，下列检测结果中，不符合现行国家标准要求的是（）。",[488,490,492,494],{"key":20,"text":489,"correct":32},"采用消防水泵转输水箱串联供水，转输水箱有效储水容积为50m3",{"key":24,"text":491,"correct":22},"比例式减压阀垂直安装，水流方向向下",{"key":27,"text":493,"correct":22},"塔楼酒店客房洒水喷头采用快速响应喷头",{"key":30,"text":495,"correct":22},"第三十层酒店大堂采用隐蔽型喷头",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":24,"analysis":33},934913,"（2019年真题）某高层公共建筑消防给水系统的系统工作压力为1.25MPa，选用的立式消防水泵参数为流量40L\u002Fs，扬程100m，对该系统进行验收前检测，下列检测结果中，不符合现行国家标准要求的是（）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"停泵时，压力表显示水锤消除设施后的压力为1.3MPa",{"key":24,"text":503,"correct":32},"流量计显示出水流量为60L\u002Fs时，压力表显示为0.6MPa",{"key":27,"text":505,"correct":22},"手动直接启泵，消防水泵在36s时投入正常运行",{"key":30,"text":507,"correct":22},"吸水管上的控制阀锁定在常开位置，并有明显标记",{"id":509,"libraryId":5,"type":36,"typeLabel":37,"stem":510,"options":511,"answer":522,"analysis":33},934914,"（2019年真题）某商业综合体建筑高度为31.6m，总建筑面积为35000㎡，设置临时高压消防给水系统。根据现行国家标准《消防给水及消火栓系统技术规范》(GB50974)，对消火栓系统进行验收下列验收检测结果中，不符合规范要求的有（）",[512,514,516,518,520],{"key":20,"text":513,"correct":22},"消防主泵切换到备用泵的时间为60秒",{"key":24,"text":515,"correct":22},"联动控制器属于手动状态时，高位消防水箱的消火栓出水干管的流量开关动作，消防水泵启动",{"key":27,"text":517,"correct":22},"消防水泵启动后不能自动停止运行",{"key":30,"text":519,"correct":32},"消防水泵吸水管上的控制阀采用暗杆闸阀，无开启刻度和标志",{"key":49,"text":521,"correct":32},"高位消防水箱有效容积为36m3，设置有水位报警装置","DE",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":27,"analysis":33},934915,"(2017年真题) 下列设施中不属于消防车取水用的设施是(??)",[527,528,529,530],{"key":20,"text":287,"correct":22},{"key":24,"text":289,"correct":22},{"key":27,"text":291,"correct":32},{"key":30,"text":293,"correct":22},{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":27,"analysis":33},934916,"(2017年真题) 根据现行国家标准《消防给水及消火栓系统技术规范》GB50974，对室内消火栓应（??）进行一次外观和漏水检查，发现存在问题的消火栓应及时修复或更换。",[535,537,539,541],{"key":20,"text":536,"correct":22},"每月",{"key":24,"text":538,"correct":22},"每半年",{"key":27,"text":540,"correct":32},"每季度",{"key":30,"text":542,"correct":22},"每年",{"id":544,"libraryId":5,"type":36,"typeLabel":37,"stem":545,"options":546,"answer":557,"analysis":33},934917,"(2017年真题) 对某民用建筑设置的消防水泵进行验收检查， 根据现行国家标准《消防给水及消火栓系统技术规范》GB50974， 关于消防水泵验收要求的做法， 正确的有（??）。",[547,549,551,553,555],{"key":20,"text":548,"correct":32},"消防水泵应采用自灌式引水方式， 并应保证全部有效储水被有效利用",{"key":24,"text":550,"correct":32},"消防水泵就地和远程启停功能应正常",{"key":27,"text":552,"correct":32},"打开消防水泵出水管上试水阀，当采用主电源启动消防水泵时，消防水泵应启动正常",{"key":30,"text":554,"correct":32},"消防水泵启动控制应置于自动启动档",{"key":49,"text":556,"correct":22},"消防水泵停泵时， 水锤消除设施后的压力不应超过水泵出口设计工作压力的1.6倍","ABCD",{"id":559,"libraryId":5,"type":36,"typeLabel":37,"stem":560,"options":561,"answer":572,"analysis":33},934918,"(2017年真题) 某服装加工厂，室内消防采用临时高压消防给水系统联合供水，稳压泵稳压，系统设计流量57L\u002Fs，室外供水干管采用DN200球磨铸铁管，埋地敷设，长度为2000m。消防检测机构现场检测结果为：室外管网漏水率为2.40L\u002F(min?km），室内管网部分漏水量为0.2L\u002Fs,该系统管网总泄漏量计算和稳压泵设计流量正确的有（??）。",[562,564,566,568,570],{"key":20,"text":563,"correct":32},"管网泄漏量0.28L\u002Fs，稳压泵设计流量1.0L\u002Fs",{"key":24,"text":565,"correct":22},"管网泄漏量0.20L\u002Fs，稳压泵设计流量0.28L\u002Fs",{"key":27,"text":567,"correct":32},"管网泄漏量0.28L\u002Fs，稳压泵设计流量1.28L\u002Fs",{"key":30,"text":569,"correct":22},"管网泄漏量0.20L\u002Fs，稳压泵设计流量1.0L\u002Fs",{"key":49,"text":571,"correct":22},"管网泄漏量0.28L\u002Fs，稳压泵设计流量0.5L\u002Fs","AC",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":20,"analysis":33},934919,"(2018年真题) 对某高层公共建筑消防给水系统进行维护检测，消防水泵测试阀开启，水泵出水干管上的压力开关动作后，消防水泵未启动。下列故障原因分析中，可排除的是（??）",[577,579,581,583],{"key":20,"text":578,"correct":32},"消防联动控制器处于手动状态",{"key":24,"text":580,"correct":22},"压力开关与水泵之间线路故障",{"key":27,"text":582,"correct":22},"消防水泵控制柜处于手动启泵状态",{"key":30,"text":584,"correct":22},"消防水泵控制柜内继电器损坏",{"id":586,"libraryId":5,"type":36,"typeLabel":37,"stem":587,"options":588,"answer":599,"analysis":33},934920,"(2018年真题) 根据现行国家标准《消防给水及消火栓系统技术规范》(GB50974)，对消防给水及消火栓系统进行验收前的检测。下列检测结果中，属于工程质量缺陷项目重缺陷项的有( )。",[589,591,593,595,597],{"key":20,"text":590,"correct":22},"消防水泵出水管上的控制阀关闭",{"key":24,"text":592,"correct":32},"消防水泵主、备泵相互切换不正常",{"key":27,"text":594,"correct":22},"消防水池吸水管喇叭口位置与设计位置存在误差",{"key":30,"text":596,"correct":32},"消防水泵运转中噪声及振动较大",{"key":49,"text":598,"correct":22},"高位消防水箱未设水位报警装置","BD",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":30,"analysis":33},934921,"(2018年真题) 某厂区室外消防给水管网管材采用钢丝网骨架塑料管，系统设计工作压力 0.5MPa，管道水压强度试验的试验压力最小应为（ ）。",[604,605,607,609],{"key":20,"text":481,"correct":22},{"key":24,"text":606,"correct":22},"0.75MPa",{"key":27,"text":608,"correct":22},"1.0MPa",{"key":30,"text":479,"correct":32},{"id":611,"libraryId":5,"type":15,"typeLabel":16,"stem":612,"options":613,"answer":27,"analysis":33},934922,"(2018年真题) 某消防工程施工单位在室内消防给水系统施工前，对采用的消防软管卷盘进行进场检验，下列检查要求和结果符合现行国家标准《消防给水及消火栓系统技术规范》(GB 50974)的是（ ）。",[614,616,618,620],{"key":20,"text":615,"correct":22},"消防软管公称内径为 16mm，长度为 30m",{"key":24,"text":617,"correct":22},"应对消防软管卷盘的密封性能进行测试，每批次抽查 2 个，以 50 个为 1 批次",{"key":27,"text":619,"correct":32},"应对消防软管卷盘外观进行全数检查",{"key":30,"text":621,"correct":22},"应对消防软管卷盘进行一般检查，检查数量从每批次中抽查 50%",{"id":623,"libraryId":5,"type":15,"typeLabel":16,"stem":624,"options":625,"answer":27,"analysis":33},934923,"(2018年真题) 在消防给水系统减压阀的维护管理中，应定期对减压阀进行检测 。其中对减压阀组进行放水试验，并检测和记录减压阀前后的压力，应（ ）。",[626,628,630,632],{"key":20,"text":627,"correct":22},"每季度一次",{"key":24,"text":629,"correct":22},"每半年一次",{"key":27,"text":631,"correct":32},"每月一次",{"key":30,"text":633,"correct":22},"每年一次",{"id":635,"libraryId":5,"type":15,"typeLabel":16,"stem":636,"options":637,"answer":24,"analysis":33},934924,"(2016年真题)某消防检测机构，检查物业公司的临时高压消防给水系统维护管理记录，发现有一条维护管理记录如下：自动和手动启动消防水泵时，水泵无法实现运转，按下控制柜的机械应急启动操纵杆时，水泵能正常运转。下来关于系统故障的原因中，正确的是（??）。",[638,640,642,644],{"key":20,"text":639,"correct":22},"自动巡检变频器故障",{"key":24,"text":641,"correct":32},"控制电器元件故障",{"key":27,"text":643,"correct":22},"电机供电回路故障",{"key":30,"text":645,"correct":22},"供电电压不足",[647,650,653,656,659,662],{"id":15,"name":648,"category":7,"favorite":649},"领导干部任职前廉政法规知识测试题",92,{"id":651,"name":652,"category":7,"favorite":15},595,"建筑结构与设备",{"id":654,"name":655,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":657,"name":658,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":660,"name":661,"category":7,"favorite":8},534,"BIM工程师",{"id":663,"name":661,"category":7,"favorite":8},535]