[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-49":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":707},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,49,50,2974,[13,38,52,66,81,96,111,126,141,156,170,185,200,215,230,244,259,273,287,302,316,331,343,358,373,387,401,415,430,444,459,473,487,501,515,529,544,558,570,582,592,604,612,623,635,647,659,671,683,695],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},937096,2,"多选题","对防火门及防火卷帘的联动控制要求正确的是（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","疏散通道上设置的防火卷帘的应具有两步关闭的功能",true,{"key":24,"text":25,"correct":22},"B","非疏散通道上设置的防火卷帘直接下降到楼板面",{"key":27,"text":28,"correct":29},"C","防火卷帘的升降应由消防联动控制器或防火卷帘控制器控制",false,{"key":31,"text":32,"correct":22},"D","疏散通道上各防火门的开启、关闭及故障状态信号应反馈至防火门监控器",{"key":34,"text":35,"correct":22},"E","疏散通道上各防火门的应由消防联动控制器或防火门监控器联动控制","ABDE","",{"id":39,"libraryId":5,"type":40,"typeLabel":41,"stem":42,"options":43,"answer":31,"analysis":37},937097,1,"单选题","根据《自动喷水灭火系统施工及验收规范》（GB 50261）的要求，下列检查项目中，属于每年应进行的是（ ）。",[44,46,48,50],{"key":20,"text":45,"correct":29},"利用末端试水装置对水流指示器进行试验",{"key":24,"text":47,"correct":29},"电磁阀的启动试验",{"key":27,"text":49,"correct":29},"内燃机驱动的消防水泵启动运转",{"key":31,"text":51,"correct":22},"水源的供水能力",{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":36,"analysis":37},937098,"下列关于消防给水管道采用沟槽连接件（卡箍）连接，正确的安装方法是（ ）。",[56,58,60,62,64],{"key":20,"text":57,"correct":22},"有振动的场所和埋地管道应采用柔性接头，其他场所宜采用刚性接头",{"key":24,"text":59,"correct":22},"沟槽式管件连接时，管道连接沟槽和开孔应用专用滚槽机和开孔机加工，并应做防腐处理",{"key":27,"text":61,"correct":29},"机械三通开孔间距不应小于0.5m，机械四通开孔间距不应小于2m",{"key":31,"text":63,"correct":22},"配水干管（立管）与配水管（水平管）连接，应采用沟槽式管件，不应采用机械三通",{"key":34,"text":65,"correct":22},"埋地的沟槽式管件的螺栓、螺帽应做防腐处理",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":80,"analysis":37},937099,"火灾自动报警系统的使用单位应建立的技术档案包括（ ）。",[70,72,74,76,78],{"key":20,"text":71,"correct":22},"系统竣工图及设备的技术资料",{"key":24,"text":73,"correct":22},"公安消防机构出具的有关法律文书",{"key":27,"text":75,"correct":22},"系统的操作规程及维护保养管理制度",{"key":31,"text":77,"correct":22},"系统操作员名册及相应的工作职责",{"key":34,"text":79,"correct":22},"值班记录和使用图表","ABCDE",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":95,"analysis":37},937100,"下列关于消防给水管道架空安装的说法中，正确的是（ ）。",[85,87,89,91,93],{"key":20,"text":86,"correct":22},"穿过地下室外墙、构筑物墙壁以及屋面等有防水要求处时，应设置防水套管",{"key":24,"text":88,"correct":29},"穿过建筑物承重墙或基础时，预留洞口高度不宜小于0.2m",{"key":27,"text":90,"correct":22},"穿过墙体或楼板时，套管长度≥墙体厚度，或高出楼面或地面50mm",{"key":31,"text":92,"correct":22},"通过及敷设在有腐蚀性气体的房间内时，管外壁应刷防腐漆或缠绕防腐材料",{"key":34,"text":94,"correct":22},"穿过伸缩缝及沉降缝时，应设置波纹管和补偿器","ACDE",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":110,"analysis":37},937101,"下列符合控制器类设备在消防控制室内布置要求的是（ ）。",[100,102,104,106,108],{"key":20,"text":101,"correct":22},"设备面盘后的维修距离不宜小于1m",{"key":24,"text":103,"correct":22},"设备面盘的排列长度大于4m时，其两端应设置宽度不小于1m的通道",{"key":27,"text":105,"correct":29},"在值班人员经常工作的一面，设备面盘至墙的距离不应小于4m",{"key":31,"text":107,"correct":29},"设备面盘前的操作距离，单列布置时不应小于1m，双列布置时不应小于2m",{"key":34,"text":109,"correct":22},"与建筑其他弱电系统合用的消防控制室内，消防设备应集中设置，并应与其他设备间有明显间隔","ABE",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":125,"analysis":37},937102,"下列关于消防给水架空管道刷涂油漆的说法中，正确的是（ ）。",[115,117,119,121,123],{"key":20,"text":116,"correct":22},"架空管道外应刷红色油漆或涂红色环圈标志",{"key":24,"text":118,"correct":22},"架空管道应注明管道名称和水流方向标识",{"key":27,"text":120,"correct":22},"红色环圈标志，宽度不应小于20mm，间隔不宜大于4m",{"key":31,"text":122,"correct":22},"在一个独立的单元内红色环圈标志不宜少于2处",{"key":34,"text":124,"correct":29},"在有特殊装修要求的场所，消防给水架空管道可刷成各种颜色，且不涂红色环圈标志","ABCD",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":140,"analysis":37},937103,"下列检测项目中，属于火灾自动报警系统年度检测特有内容的有（ ）。",[130,132,134,136,138],{"key":20,"text":131,"correct":29},"试验火灾警报装置的声光显示试验",{"key":24,"text":133,"correct":22},"强制切断非消防电源功能试验",{"key":27,"text":135,"correct":29},"消防电梯迫降功能试验",{"key":31,"text":137,"correct":22},"对所安装的全部探测器和手动报警装置进行一次试验",{"key":34,"text":139,"correct":29},"检查火灾报警控制器的功能","BD",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":155,"analysis":37},937104,"下列自动灭火系统中，可以使用火灾自动报警系统联动控制的是（ ）。",[145,147,149,151,153],{"key":20,"text":146,"correct":29},"干式系统",{"key":24,"text":148,"correct":22},"预作用式系统",{"key":27,"text":150,"correct":22},"雨淋系统",{"key":31,"text":152,"correct":22},"水幕系统",{"key":34,"text":154,"correct":22},"水喷雾系统","BCDE",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":155,"analysis":37},937105,"建筑物室外宜采用低压消防给水系统，当采用市政给水管网供水时，应采用两路消防供水，下列建筑可以采用一路消防供水的是（ ）。",[160,162,164,166,168],{"key":20,"text":161,"correct":29},"建筑高度为55米的住宅建筑",{"key":24,"text":163,"correct":22},"建筑高度为49米的住宅建筑",{"key":27,"text":165,"correct":22},"建筑高度为50米的住宅，室外消火栓设计流量20L\u002Fs",{"key":31,"text":167,"correct":22},"建筑高度为45米的住宅，室外消火栓设计流量15L\u002Fs",{"key":34,"text":169,"correct":22},"室外消火栓设计流量10L\u002Fs",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":184,"analysis":37},937106,"下列关于利用有压气体作为系统启动介质的干式系统、预作用系统的叙述中，正确的是（ ）。",[174,176,178,180,182],{"key":20,"text":175,"correct":22},"干式系统配水管道内充入有压气体的目之一是将有压气体作为传递火警信号的介质",{"key":24,"text":177,"correct":22},"干式系统配水管道内充入有压气体的目之一是防止干式报警阀误动作",{"key":27,"text":179,"correct":29},"常规的预作用系统配水管道内充入有压气体的目之一是将有压气体作为传递火警信号的介质",{"key":31,"text":181,"correct":22},"常规的预作用系统配水管道内充入有压气体的目之一是将有压气体作为监测管道严密性的介质",{"key":34,"text":183,"correct":29},"利用有压气体检测管道是否严密的预作用系统，配水管道内的气压值不宜小于0.03MPa，且不宜大于0.10MPa","ABD",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":199,"analysis":37},937107,"某地下车库，设置的自动喷水灭火系统采用直立型喷头，下列关于喷头溅水盘与车库顶板的垂直距离的说法，符合规范规定的有（ ）。",[189,191,193,195,197],{"key":20,"text":190,"correct":29},"喷头无障碍物遮挡时，不应小于25mm，不应大于150mm",{"key":24,"text":192,"correct":29},"喷头有障碍物遮挡时，不应大于850mm",{"key":27,"text":194,"correct":22},"喷头无障碍物遮挡时，不应小于75mm，不应大于150mm",{"key":31,"text":196,"correct":29},"喷头有障碍物遮挡时，不应大于650mm",{"key":34,"text":198,"correct":22},"喷头有障碍物遮挡时，不应大于550mm","CE",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":214,"analysis":37},937108,"屋顶消防水箱进水管径设计为DN40，则下列溢流管直径设计符合规范要求的是（ ）。",[204,206,208,210,212],{"key":20,"text":205,"correct":29},"DN50",{"key":24,"text":207,"correct":29},"DN80",{"key":27,"text":209,"correct":22},"DN100",{"key":31,"text":211,"correct":22},"DN125",{"key":34,"text":213,"correct":22},"DN150","CDE",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":229,"analysis":37},937109,"某建筑高度为25m的办公建筑，地上部分全部为办公，地下2层为汽车库，建筑内部全部设置自动喷水灭火系统，下列关于该自动喷水灭火系统的做法中，正确的有（ ）。",[219,221,223,225,227],{"key":20,"text":220,"correct":22},"办公楼层采用玻璃球色标为红色的喷头",{"key":24,"text":222,"correct":29},"办公室采用边墙型喷头",{"key":27,"text":224,"correct":22},"汽车库内一只喷头的最大保护面积为11.5m2",{"key":31,"text":226,"correct":22},"汽车库采用直立型喷头",{"key":34,"text":228,"correct":29},"办公楼层内一只喷头的最大保护面积为20.0m2","ACD",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":214,"analysis":37},937110,"某建筑采用临时高压给水系统，消防水泵的工作压力为1.0MPa，当出水流量为设计流量的1.5倍时，其出口压力可以为下列（ ）。",[234,236,238,240,242],{"key":20,"text":235,"correct":29},"0.5MPa",{"key":24,"text":237,"correct":29},"0.6MPa",{"key":27,"text":239,"correct":22},"0.7MPa",{"key":31,"text":241,"correct":22},"0.8MPa",{"key":34,"text":243,"correct":22},"0.9MPa",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":258,"analysis":37},937111,"某工程室内消火栓水泵（一用一备）流量为40L\u002Fs，扬程为100m，以下关于消火栓泵组的叙述错误的是（ ）。",[248,250,252,254,256],{"key":20,"text":249,"correct":22},"该泵组应预留测量用流量计",{"key":24,"text":251,"correct":29},"流量检测装置最大量程为94L\u002Fs",{"key":27,"text":253,"correct":29},"压力检测装置的最大量程为230m",{"key":31,"text":255,"correct":29},"每台消防水泵出水管上应设置DN65的试水管，并应采取排水措施",{"key":34,"text":257,"correct":22},"该泵组应预留测量用压力计接口","AE",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":184,"analysis":37},937112,"下列关于水幕喷头布置的叙述中，（ ）是正确的。",[263,265,267,269,271],{"key":20,"text":264,"correct":22},"防火分隔水幕采用水幕喷头时，喷头不应少于3排",{"key":24,"text":266,"correct":22},"防火分隔水幕采用开式洒水喷头时，喷头不应少于2排",{"key":27,"text":268,"correct":29},"防护冷却水幕的喷头宣布置成2排",{"key":31,"text":270,"correct":22},"防火分隔水幕的喷头布置，应保证水幕的宽度不小于6m",{"key":34,"text":272,"correct":29},"防火分隔水幕不宜用于尺寸为16m（宽）x8m（高）的舞台口",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":214,"analysis":37},937113,"某3层图书馆，建筑面积为12000㎡，室内最大净宽高度为4.5m，图书馆内全部设置自动喷水灭火系统等，下列关于该自动喷水灭火系统的做法中，正确的有（ ）。",[277,279,281,283,285],{"key":20,"text":278,"correct":29},"系统的喷水强度为4L\u002Fs（min·㎡）",{"key":24,"text":280,"correct":29},"共设置1套湿式报警阀组",{"key":27,"text":282,"correct":22},"采用流量系数K=80的洒水喷头",{"key":31,"text":284,"correct":22},"系统的作用面积为160㎡",{"key":34,"text":286,"correct":22},"系统最不利点处喷头的工作压力为0.1MPa",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":301,"analysis":37},937114,"下列高层建筑室内临时高压消火栓给水系统的消防主泵房启、停控制方式中，不正确的是（ ）。",[291,293,295,297,299],{"key":20,"text":292,"correct":22},"每个消火栓处应能直接启动消防主泵",{"key":24,"text":294,"correct":29},"消防控制中心应能手动启动消防主泵",{"key":27,"text":296,"correct":29},"消防水泵房应能强制启、停消防主泵",{"key":31,"text":298,"correct":22},"消防水池最低水位应能自动停止消防水泵",{"key":34,"text":300,"correct":29},"消防水泵控制柜应设置机械应急启泵功能","AD",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":36,"analysis":37},937115,"下列关于消防水泵的叙述中，（ ）是正确的。",[306,308,310,312,314],{"key":20,"text":307,"correct":22},"一组消防水泵应设不少于2条的输水干管与消防给水环状给水管网连接，当其中一条输水管检修时，其余输水管应仍能供应全部消防给水设计流量",{"key":24,"text":309,"correct":22},"一组消防水泵，吸水管不应少于2条。当其中一条损坏或检修时，其余吸水管应仍能通过全部设计流量",{"key":27,"text":311,"correct":29},"消防水泵的吸水管上应设置明杆闸阀或暗杆蝶阀，但当设置暗杆阀门时应设有开启刻度和标志；当管径超过DN300时，宜设置电动阀门",{"key":31,"text":313,"correct":22},"消防水泵的出水管上应设置止回阀、明杆闸阀；当采用蝶阀时，应带有自锁装置",{"key":34,"text":315,"correct":22},"消防水泵的吸水管穿越消防水池时，应采用柔性套管；采用刚性防水套管时应在水泵吸水管上设置柔性接头，且管径不应大于DN150",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":330,"analysis":37},937116,"组件（ ）是各类报警阀组（装置）都可以有的。",[320,322,324,326,328],{"key":20,"text":321,"correct":29},"延时器",{"key":24,"text":323,"correct":22},"压力开关",{"key":27,"text":325,"correct":22},"水力警铃",{"key":31,"text":327,"correct":22},"信号阀",{"key":34,"text":329,"correct":29},"电磁阀","BCD",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":95,"analysis":37},937117,"自动喷水灭火系统安装检查中，需要与消防中心控制线路相连接的组件是（ ）。",[335,336,338,340,342],{"key":20,"text":323,"correct":22},{"key":24,"text":337,"correct":29},"末端试水装置",{"key":27,"text":339,"correct":22},"信号蝶阀",{"key":31,"text":341,"correct":22},"水流指示器",{"key":34,"text":329,"correct":22},{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":357,"analysis":37},937118,"某工程消防水泵出水管管径为DN150，该出水管上应设置（ ）。",[347,349,351,353,355],{"key":20,"text":348,"correct":22},"明杆闸阀",{"key":24,"text":350,"correct":22},"止回阀",{"key":27,"text":352,"correct":22},"带自锁装置的蝶阀",{"key":31,"text":354,"correct":29},"电动阀门",{"key":34,"text":356,"correct":29},"倒流防止器","ABC",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":372,"analysis":37},937119,"下列消防给水应采用环状给水管网的是（ ）。",[362,364,366,368,370],{"key":20,"text":363,"correct":22},"向两栋或两座及以上建筑供水时",{"key":24,"text":365,"correct":22},"向两种及以上水灭火系统供水时",{"key":27,"text":367,"correct":22},"采用设有高位消防水箱的临时高压消防给水系统时",{"key":31,"text":369,"correct":29},"室外消防给水采用一路消防供水时",{"key":34,"text":371,"correct":22},"向两个及以上报警阀控制的自动水灭火系统供水时","ABCE",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":125,"analysis":37},937120,"可能导致湿式报警阀组漏水的原因有（ ）。",[377,379,381,383,385],{"key":20,"text":378,"correct":22},"排水阀门未完全关闭",{"key":24,"text":380,"correct":22},"报警管路测试控制阀渗漏",{"key":27,"text":382,"correct":22},"阀瓣密封垫老化或者损坏",{"key":31,"text":384,"correct":22},"系统侧管道接口渗漏",{"key":34,"text":386,"correct":29},"限流装置过滤网被堵塞",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":125,"analysis":37},937121,"下列关于室外消防给水管网布置正确的是（ ）。",[391,393,395,397,399],{"key":20,"text":392,"correct":22},"室外消防给水采用两路消防供水时应采用环状管网，但当采用一路消防供水时可采用枝状管网",{"key":24,"text":394,"correct":22},"管道的直径应根据流量、流速和压力要求经计算确定，但不应小于DN100",{"key":27,"text":396,"correct":22},"消防给水管道应采用阀门分成若干独立段，每段内室外消火栓的数量不宜超过5个",{"key":31,"text":398,"correct":22},"建筑物室外宜采用低压消防给水系统，室外消火栓应由市政给水管网直接供水",{"key":34,"text":400,"correct":29},"室外消火栓设计流量小于等于20L\u002Fs时可采用一路消防供水",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":125,"analysis":37},937122,"报警阀报警管路误报警，可能的原因有（ ）。",[405,407,409,411,413],{"key":20,"text":406,"correct":22},"报警阀安装错误",{"key":24,"text":408,"correct":22},"安装完后未按要求调试",{"key":27,"text":410,"correct":22},"报警阀组渗漏通过报警管路流出",{"key":31,"text":412,"correct":22},"延迟器下部孔板溢出水孔堵塞",{"key":34,"text":414,"correct":29},"限流装置过滤网堵塞",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":429,"analysis":37},937123,"下列关于室内消防给水管网布置正确的是（ ）。",[419,421,423,425,427],{"key":20,"text":420,"correct":29},"室内消火栓系统管网应布置成环状，当室外消火栓设计流量不大于20L\u002Fs，且室内消火栓不超过15个时，可布置成枝状",{"key":24,"text":422,"correct":22},"室内消火栓竖管管径应根据竖管最低流量经计算确定，但不应小于DN100",{"key":27,"text":424,"correct":22},"汽车库、修车库的室内消火栓数量超过10个时，室内消防管道应布置成环状，并应有两条进水管与室外管道相连接",{"key":31,"text":426,"correct":29},"室内消防管道应采用阀门分成若干独立段，每段内消火栓不应超过5个",{"key":34,"text":428,"correct":29},"室内消火栓给水管网宜与自动喷水等其他水灭火系统的管网分开设置；当合用消防泵时，供水管路沿水流方向应在报警阀后分开设置","BC",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":199,"analysis":37},937124,"下列关于减压阀的设置与应用正确的是（ ）。",[434,436,438,440,442],{"key":20,"text":435,"correct":29},"减压阀应设置在报警阀组后，当连接两个及以上报警阀组时，应设置备用减压阀。",{"key":24,"text":437,"correct":29},"减压阀的进口处应设置过滤器，过滤器的孔网直径不宜小于4~5目\u002Fcm2，过流面积不应小于管道截面面积的2倍。",{"key":27,"text":439,"correct":22},"过滤器和减压阀前后应设压力表，压力表的表盘直径不应小于100mm，最大量程宜为设计压力的2倍。",{"key":31,"text":441,"correct":29},"比例式减压阀宜水平安装，可调式减压阀宜垂直安装。",{"key":34,"text":443,"correct":22},"减压阀应设置流量检测测试接口或流量计",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":458,"analysis":37},937125,"下列关于消防排水的设置正确的是（ ）。",[448,450,452,454,456],{"key":20,"text":449,"correct":29},"消防电梯的井底排水泵集水井的有效容量不应小于1.00m3",{"key":24,"text":451,"correct":22},"消防电梯的井底排水泵的排水量不应小于10L\u002Fs",{"key":27,"text":453,"correct":29},"自动喷水灭火系统等自动水灭火系统末端试水装置处的排水立管管径，应根据末端试水装置的泄流量确定，并不宜小于DN25",{"key":31,"text":455,"correct":29},"报警阀处的排水立管宜为DN75",{"key":34,"text":457,"correct":22},"减压阀处的压力试验排水管道直径应根据减压阀流量确定，但不应小于DN100","BE",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":458,"analysis":37},937126,"关于稳压泵的流量和压力的确定，下列说法中错误的是（ ）。",[463,465,467,469,471],{"key":20,"text":464,"correct":29},"消防给水系统稳压泵的设计流量不应小于消防给水系统管网的正常泄露量和系统自动启动流量",{"key":24,"text":466,"correct":22},"稳压泵设计流量宜按消防给水设计流量的的1%～5%，且不宜小于1L\u002Fs",{"key":27,"text":468,"correct":29},"稳压泵的设计压力应满足系统自动启动和管网充满水的要求",{"key":31,"text":470,"correct":29},"稳压泵的设计压力应保持系统最不利点处水灭火设施静水压力应大于0.15MPa",{"key":34,"text":472,"correct":22},"采用气压罐时，其调节容积应根据稳压泵启泵次数不大于10次\u002F11计算确定，有效容积不宜小于150L。",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":125,"analysis":37},937127,"秒表在在建设工程消防施工质量控制、技术检测、维护管理及消防产品现场检查中广泛使用，可以用来测量（ ）。",[477,479,481,483,485],{"key":20,"text":478,"correct":22},"火灾自动报警系统的响应时间",{"key":24,"text":480,"correct":22},"水流指示器的延迟时间",{"key":27,"text":482,"correct":22},"干式、预作用系统充水时间",{"key":31,"text":484,"correct":22},"末端试水装置出水时间检测报警阀组功能",{"key":34,"text":486,"correct":29},"管网水压严密性试验稳压时间",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":125,"analysis":37},937128,"下列场所中应设置消防水泵接合器的是（ ）。",[491,493,495,497,499],{"key":20,"text":492,"correct":22},"高层民用建筑室内消火栓给水系统",{"key":24,"text":494,"correct":22},"高层工业建筑和超过四层的多层工业建筑室内消火栓系统",{"key":27,"text":496,"correct":22},"城市交通隧道室内消火栓系统",{"key":31,"text":498,"correct":22},"自动喷水灭火系统、水喷雾、泡沫灭火系统",{"key":34,"text":500,"correct":29},"建筑面积大于8000m2的地下或半地下建筑（室）",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":258,"analysis":37},937129,"下列关于水泵接合器设置的描述中正确的是（ ）。",[505,507,509,511,513],{"key":20,"text":506,"correct":22},"消防水泵接合器的给水流量宜按每个10L\u002Fs～15L\u002Fs计算",{"key":24,"text":508,"correct":29},"水泵接合器宜设在室外便于消防车使用的地方，距室外消火栓或消防水池距离宜为5-40米",{"key":27,"text":510,"correct":29},"墙壁消防水泵接合器安装高度距地面宜为0.8米",{"key":31,"text":512,"correct":29},"地下消防水泵接合器的安装，应使进水口与井盖底面距离不大于0.5米",{"key":34,"text":514,"correct":22},"水泵接合器处应设永久性标志铭牌",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":330,"analysis":37},937130,"下列关于高层民用建筑水泵接合器的叙述中，（ ）是错误的。",[519,521,523,525,527],{"key":20,"text":520,"correct":29},"每个水泵接合器的流量应按10～15L\u002Fs计算",{"key":24,"text":522,"correct":22},"采用串联给水方式时，各区应分别设水泵接合器",{"key":27,"text":524,"correct":22},"水泵接合器距室外消火栓或消防水池的距离不宜小于15m，并不应大于40m。为消防水泵接合器供水的市政消火栓，距建筑外缘5m~120m的市政消火栓可计入建筑室外消火栓的数量",{"key":31,"text":526,"correct":22},"地下消防水泵接合器的安装，应使进水口与井盖底面的距离不小于0.4m，且不应小于井盖的半径",{"key":34,"text":528,"correct":29},"消防水泵接合器的供水范围，应根据当地消防车的供水流量和压力确定",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":543,"analysis":37},937131,"关于消防水泵接合器设置的说法中正确的是（ ）。",[533,535,537,539,541],{"key":20,"text":534,"correct":22},"湿式自动喷水灭火系统、预作用灭火系统、雨淋灭火系统等水灭火系统，均应设置消防水泵接合器",{"key":24,"text":536,"correct":29},"当同一建筑设置多种自动喷水灭火系统时，水泵接合器可以共用",{"key":27,"text":538,"correct":22},"同一建筑消防给水竖向分区供水时，在消防车供水压力范围内的分区，应分别设置水泵接合器",{"key":31,"text":540,"correct":29},"临时高压消防给水系统向多栋建筑供水时，消防水泵接合器应在消防水泵房附近集中设置",{"key":34,"text":542,"correct":29},"每栋设置的水泵接合器距室外消火栓的距离不宜小于5m，并不宜大于40m","AC",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":95,"analysis":37},937132,"在防烟排烟系统中，需要半年检查的部件有（ ）。",[548,550,552,554,556],{"key":20,"text":549,"correct":22},"防火阀",{"key":24,"text":551,"correct":29},"挡烟垂壁",{"key":27,"text":553,"correct":22},"送风阀",{"key":31,"text":555,"correct":22},"排烟阀",{"key":34,"text":557,"correct":22},"排烟防火阀",{"id":559,"libraryId":5,"type":40,"typeLabel":41,"stem":560,"options":561,"answer":27,"analysis":37},937133,"排烟风机一般可采用离心风机、排烟专用的混流风机或轴流风机，也有采用风机箱或屋顶式风机，排烟风机应保证在280℃的环境条件下能连续工作不少于（ ）min。",[562,564,566,568],{"key":20,"text":563,"correct":29},"10",{"key":24,"text":565,"correct":29},"20",{"key":27,"text":567,"correct":22},"30",{"key":31,"text":569,"correct":29},"40",{"id":571,"libraryId":5,"type":40,"typeLabel":41,"stem":572,"options":573,"answer":27,"analysis":37},937134,"排烟防火阀安装在机械排烟系统的管道上，平时呈开启状态，火灾时当排烟管道内温度达到（ ）℃时关闭，并在一定时间内能满足漏烟量和耐火完整性要求，起隔烟阻火作用的阀门。排烟防火阀一般由阀体、叶片、执行机构和温感器等部分组成。",[574,576,578,580],{"key":20,"text":575,"correct":29},"70",{"key":24,"text":577,"correct":29},"150",{"key":27,"text":579,"correct":22},"280",{"key":31,"text":581,"correct":29},"380",{"id":583,"libraryId":5,"type":40,"typeLabel":41,"stem":584,"options":585,"answer":27,"analysis":37},937135,"（ ）是安装在机械排烟系统的风管（风道）侧壁上作为烟气吸入口，平时呈关闭状态并满足允许漏风量要求，火灾或需要排烟时手动或电动打开，起排烟作用，外加带有装饰口或进行过装饰处理的阀门。",[586,588,589,591],{"key":20,"text":587,"correct":29},"排烟管道",{"key":24,"text":557,"correct":29},{"key":27,"text":590,"correct":22},"排烟口",{"key":31,"text":551,"correct":29},{"id":593,"libraryId":5,"type":40,"typeLabel":41,"stem":594,"options":595,"answer":31,"analysis":37},937136,"挡烟垂壁是用于分隔防烟分区的装置或设施，可分为固定式或活动式。对于固定式可采用不小于（ ）mm的隔墙、楼板下的梁或吊顶下凸出不燃烧体。",[596,598,600,602],{"key":20,"text":597,"correct":29},"200",{"key":24,"text":599,"correct":29},"300",{"key":27,"text":601,"correct":29},"400",{"key":31,"text":603,"correct":22},"500",{"id":605,"libraryId":5,"type":40,"typeLabel":41,"stem":606,"options":607,"answer":31,"analysis":37},937137,"排烟金属风管的隔热层应采用厚度不小于（ ）mm的不燃绝热材料（如矿棉、岩棉、硅酸铝等），绝热材料的施工及风管加固、导流片的设置应按国家标准有关规定执行。",[608,609,610,611],{"key":20,"text":563,"correct":29},{"key":24,"text":565,"correct":29},{"key":27,"text":567,"correct":29},{"key":31,"text":569,"correct":22},{"id":613,"libraryId":5,"type":40,"typeLabel":41,"stem":614,"options":615,"answer":24,"analysis":37},937138,"活动挡烟垂壁与建筑结构（柱或墙）面的缝隙不应大于（ ）mm，由两块或两块以上的挡烟垂帘组成的连续性挡烟垂壁，各块之间不应有缝隙，搭接宽度不应小于100mm。",[616,617,619,621],{"key":20,"text":567,"correct":29},{"key":24,"text":618,"correct":22},"60",{"key":27,"text":620,"correct":29},"90",{"key":31,"text":622,"correct":29},"120",{"id":624,"libraryId":5,"type":40,"typeLabel":41,"stem":625,"options":626,"answer":31,"analysis":37},937139,"下列防烟排烟系统调试单机调试对防火阀、排烟防火阀调试说法中，不符合要求的是（ ）。",[627,629,631,633],{"key":20,"text":628,"correct":29},"进行手动关闭、复位试验，阀门动作应灵敏、可靠，关闭应严密",{"key":24,"text":630,"correct":29},"模拟火灾，相应区域火灾报警后，同一防火区域内阀门应联动关闭",{"key":27,"text":632,"correct":29},"阀门关闭后的状态信号应能反馈到消防控制室",{"key":31,"text":634,"correct":22},"阀门关闭后应能联动相应的风机开启",{"id":636,"libraryId":5,"type":40,"typeLabel":41,"stem":637,"options":638,"answer":27,"analysis":37},937140,"某商场设有机械排烟排烟系统，排烟风机采用离心风机箱，该风机应保证在（ ）℃的环境条件下能连续工作不少于（ ）min。",[639,641,643,645],{"key":20,"text":640,"correct":29},"70,10",{"key":24,"text":642,"correct":29},"150,20",{"key":27,"text":644,"correct":22},"280,30",{"key":31,"text":646,"correct":29},"380,40",{"id":648,"libraryId":5,"type":40,"typeLabel":41,"stem":649,"options":650,"answer":24,"analysis":37},937141,"排烟管道采用不燃材料制作，常用的排烟管道采用镀锌钢板加工制作，厚度按（ ）系统要求，并应采取隔热防火措施或与可燃物保持不小于（ ）mm的距离。",[651,653,655,657],{"key":20,"text":652,"correct":29},"中压，100",{"key":24,"text":654,"correct":22},"高压，150",{"key":27,"text":656,"correct":29},"中压，200",{"key":31,"text":658,"correct":29},"低压，250",{"id":660,"libraryId":5,"type":40,"typeLabel":41,"stem":661,"options":662,"answer":24,"analysis":37},937142,"活动挡烟垂壁的手动操作按钮应固定安装在便于操作、明显可见处，距楼地面（ ）m。",[663,665,667,669],{"key":20,"text":664,"correct":29},"1.1-1.3",{"key":24,"text":666,"correct":22},"1.3-1.5",{"key":27,"text":668,"correct":29},"1.5-1.7",{"key":31,"text":670,"correct":29},"1.7-1.9",{"id":672,"libraryId":5,"type":40,"typeLabel":41,"stem":673,"options":674,"answer":20,"analysis":37},937143,"排烟系统排烟口距可燃物或可燃构件的距离不应小于（ ）m。",[675,677,679,681],{"key":20,"text":676,"correct":22},"1.5",{"key":24,"text":678,"correct":29},"2.5",{"key":27,"text":680,"correct":29},"3.5",{"key":31,"text":682,"correct":29},"4.5",{"id":684,"libraryId":5,"type":40,"typeLabel":41,"stem":685,"options":686,"answer":27,"analysis":37},937144,"防烟排烟系统安装前检查主要对系统组件、材料、设备到场后，对其外观、规格型号、基本性能、严密性等进行检查。下列检查内容和要求不符合规定的是（ ）。",[687,689,691,693],{"key":20,"text":688,"correct":29},"风管的材料品种、规格、厚度等应符合设计要求和国家现行标准的规定",{"key":24,"text":690,"correct":29},"有耐火极限要求的风管的本体、框架与固定材料、密封垫料等必须为不燃材料，材料品种、规格、厚度及耐火极限等应符合设计要求和国家现行标准的规定",{"key":27,"text":692,"correct":22},"防火阀、送风口和排烟阀（口）的驱动装置，动作应可靠，在平均工作压力下工作正常",{"key":31,"text":694,"correct":29},"防烟、排烟系统柔性短管的制作材料必须为不燃材料",{"id":696,"libraryId":5,"type":40,"typeLabel":41,"stem":697,"options":698,"answer":27,"analysis":37},937145,"防排烟系统施工安装前，对风管阀（口）进行现场检验时，下列检查项目中，不属于现场检查项目的是（ ）。",[699,701,703,705],{"key":20,"text":700,"correct":29},"电动防火阀",{"key":24,"text":702,"correct":29},"送风口",{"key":27,"text":704,"correct":22},"正压送风机",{"key":31,"text":706,"correct":29},"柔性短管",[708,711,714,717,720,723],{"id":40,"name":709,"category":7,"favorite":710},"领导干部任职前廉政法规知识测试题",92,{"id":712,"name":713,"category":7,"favorite":40},595,"建筑结构与设备",{"id":715,"name":716,"category":7,"favorite":40},715,"招标采购专业知识与法律法规",{"id":718,"name":719,"category":7,"favorite":40},848,"市政方向-通用基础",{"id":721,"name":722,"category":7,"favorite":8},534,"BIM工程师",{"id":724,"name":722,"category":7,"favorite":8},535]