[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-48":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":706},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,48,50,2974,[13,34,46,58,70,82,100,112,124,136,148,160,175,190,202,217,229,244,256,268,283,298,313,325,340,354,368,380,395,410,424,436,451,465,480,495,509,523,537,551,565,579,593,607,622,636,650,664,679,691],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},937046,1,"单选题","对火灾报警系统的探测器的设置要求不正确的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","探测区域的每个房间应至少设置一只火灾探测器",false,{"key":24,"text":25,"correct":22},"B","线型光束感烟探测器的设置应保证其接收端避开日光和人工光源直接照射",{"key":27,"text":28,"correct":22},"C","设置线型感温火灾探测器的场所有联动要求时，宜采用两只不同火灾探测器的报警信号组合",{"key":30,"text":31,"correct":32},"D","管路采样式吸气感烟火灾探测器当采样管道采用毛细管布置方式时，毛细管长度不宜超过3m",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},937047,"下列关于自动喷水灭火系统水平配水管上敷设减压孔板的叙述中，正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"在管径DN40mm的配水管上设孔口直径d40mm的不锈钢孔板",{"key":24,"text":41,"correct":22},"在管径DN150mm的配水管上设孔口直径d40mm的不锈钢孔板",{"key":27,"text":43,"correct":32},"在管径DN100mm的配水管上设孔口直径d32mm的不锈钢孔板",{"key":30,"text":45,"correct":22},"在管径DN100mm的配水管上设孔口直径d32mm的碳钢孔板",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},937048,"消防系统中，干式消火栓系统的充水时间不应大于（ ）min，干式自动喷水灭火系统的配水管道充水时间，不宜大于（ ）min；预作用系统与雨淋系统的配水管道充水时间，不宜大于（ ） min。",[50,52,54,56],{"key":20,"text":51,"correct":22},"10，1，2",{"key":24,"text":53,"correct":22},"10，2，1",{"key":27,"text":55,"correct":32},"5，1，2",{"key":30,"text":57,"correct":22},"5，2，1",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},937049,"火灾探测报警系统由火灾报警控制器、触发器件、火灾报警装置、（ ）等组成。",[62,64,66,68],{"key":20,"text":63,"correct":22},"火灾探测器",{"key":24,"text":65,"correct":22},"手动火灾报警按钮",{"key":27,"text":67,"correct":32},"电源",{"key":30,"text":69,"correct":22},"火灾监控器",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":30,"analysis":33},937050,"对报警阀组及附件安装时不正确的有（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"干式报警阀、预作用报警阀安装在温度不低于4℃的室内，防止冰冻",{"key":24,"text":77,"correct":22},"干式报警阀、预作用报警阀充气连接管接口在报警阀气室充注水位以上部位，且充气连接管的直径不应小于15mm；止回阀、截止阀安装在充气连接管上",{"key":27,"text":79,"correct":22},"干式报警阀、预作用报警阀安装完成后，向报警阀气室注入高度为50~100mm的清水以封闭阀瓣",{"key":30,"text":81,"correct":32},"安全排气阀安装报警阀后平时充气管路总干管上",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":99,"analysis":33},937051,2,"多选题","消防技术服务机构对某单位的预作用自动喷水灭火系统进行竣工验收，管网部分验收记录如下，其中检查数量和检查方法错误的有（ ）。",[88,90,92,94,96],{"key":20,"text":89,"correct":22},"对照图纸观察检查系统中的末端试水装置、试水阀、排气阀，符合设计要求",{"key":24,"text":91,"correct":32},"抽查设计数量20%的闸阀，合格率为100%",{"key":27,"text":93,"correct":32},"抽查设计数量20%的柔性接头，合格率为100%",{"key":30,"text":95,"correct":32},"抽查设计数量10%的各类支架、吊架和防晃支架，合格率为100%",{"key":97,"text":98,"correct":22},"E","用秒表测量管道充水时间为1min，合格","BCD",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":27,"analysis":33},937052,"施工完成后对报警阀组调试时错误的有（ ）。",[104,106,108,110],{"key":20,"text":105,"correct":22},"湿式报警阀调试时，在试水装置处放水，压力表测得当湿式报警阀进口水压大于0.14MPa、流量计读数显示放水流量大于1L\u002Fs时，报警阀启动",{"key":24,"text":107,"correct":22},"湿式报警阀组的水力警铃在秒表读数12s时发出报警铃声",{"key":27,"text":109,"correct":32},"干式报警阀调试时，开启系统试验阀，水流到试验装置出口所需时间为5min",{"key":30,"text":111,"correct":22},"雨淋阀调试时，当报警水压为0.05MPa，水力警铃发出报警铃声",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":27,"analysis":33},937053,"消防给水管网施工完成后，需要进行试压和冲洗试验。对于消防给水及消火栓系统，正确的操作顺序是（ ）。",[116,118,120,122],{"key":20,"text":117,"correct":22},"管网冲洗、水压强度试验、严密性试验",{"key":24,"text":119,"correct":22},"水压强度试验、严密性试验、管网冲洗",{"key":27,"text":121,"correct":32},"水压强度试验、管网冲洗、严密性试验",{"key":30,"text":123,"correct":22},"管网冲洗、严密性试验、水压强度试验",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":24,"analysis":33},937054,"点型感烟火灾探测器的保护面积和保护半径受安装场所内多种因素影响，正确掌握这些因素的影响规律有利于感烟火灾探测器的选型和设置。下列关于点型感烟火灾探测器保护面积和保护半径的说法，不正确的是（ ）。",[128,130,132,134],{"key":20,"text":129,"correct":22},"同样条件下，屋脊坡度越大，保护半径也越大",{"key":24,"text":131,"correct":32},"同样条件下，房间高度越高，保护半径也越小",{"key":27,"text":133,"correct":22},"探测器的保护面积和屋脊坡度、房间高度、房间地面面积有关",{"key":30,"text":135,"correct":22},"探测器保护面积和保护半径是确定探测器安装间距的重要依据",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":27,"analysis":33},937055,"下列关于消防给水及消火栓系统的试压和冲洗的说法中，正确的是（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":22},"气压严密性试验中，管网内缓慢充入空气，达到试验压力0.28MPa后，稳压2h，压力降不大于0.01MPa",{"key":24,"text":143,"correct":22},"水压强度测试点应设置在系统管网的最低点，在达到强度试验压力后，稳压2h，管网无泄漏、无变形，且压力降不大于0.05MPa，则管道强度符合要求",{"key":27,"text":145,"correct":32},"管网冲洗顺序应先地下后地上，应按供水干管、水平管和立管的顺序进行",{"key":30,"text":147,"correct":22},"消火栓系统管网强度测试和严密测试后，对管网进行分段冲洗",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":30,"analysis":33},937056,"当系统的工作压力大于2.4MPa时，应采用消防水泵串联或（ ）分区供水形式。",[152,154,156,158],{"key":20,"text":153,"correct":22},"泄水阀",{"key":24,"text":155,"correct":22},"减压阀",{"key":27,"text":157,"correct":22},"报警阀组",{"key":30,"text":159,"correct":32},"减压水箱",{"id":161,"libraryId":5,"type":84,"typeLabel":85,"stem":162,"options":163,"answer":174,"analysis":33},937057,"消火栓系统管道施工完后进行试压和冲洗，下列操作过程的描述中满足要求的是（ ）。",[164,166,168,170,172],{"key":20,"text":165,"correct":32},"管网安装完毕后，应对其进行强度试验、冲洗和严密性试验。强度试验和严密性试验宜用水进行。干式消火栓系统应做水压试验和气压试验",{"key":24,"text":167,"correct":32},"消防给水系统的水源干管、进户管和室内埋地管道应在回填前单独或与系统同时进行水压强度试验和水压严密性试验",{"key":27,"text":169,"correct":22},"管网冲洗应在试压合格后分段进行。冲洗顺序应先室外，后室内；先地上，后地下；室内部分的冲洗应按供水干管、水平管和立管的顺序进行",{"key":30,"text":171,"correct":32},"水压强度试验的测试点应设在系统管网的最低点，水压严密性试验应在水压强度试验和管网冲洗合格后进衍",{"key":97,"text":173,"correct":22},"管网冲洗的水流方向应与灭火时管网的水流方向相反，从小管径到大管径。管网冲洗结束后，应将管网内的水排除干净，干式消火栓系统还宜采用压缩空气吹干","ABD",{"id":176,"libraryId":5,"type":84,"typeLabel":85,"stem":177,"options":178,"answer":189,"analysis":33},937058,"消防给水系统分区给水的形式有（ ）。",[179,181,183,185,187],{"key":20,"text":180,"correct":32},"消防水泵并行或串联分区",{"key":24,"text":182,"correct":22},"消防水泵并联分区",{"key":27,"text":184,"correct":22},"消防水泵直接供水不分区",{"key":30,"text":186,"correct":32},"减压阀减压分区",{"key":97,"text":188,"correct":32},"减压水箱减压分区","ADE",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":27,"analysis":33},937059,"在对火灾报警控制器进行调试时，出现的下列情况不符合消防技术标准的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"按下控制器上的自检键，控制器开始自检，完成自检功能后自行停止",{"key":24,"text":197,"correct":22},"使控制器与探测器之间的连线断路，控制器在90s时发出故障声、光信号",{"key":27,"text":199,"correct":32},"在故障声、光信号存续期间，按下消音键，故障声信号消除，故障光信号依然保持，再次模拟故障信号，控制器未发出故障声信号",{"key":30,"text":201,"correct":22},"使总线隔离器保护范围内的任一点短路，总线隔离器保护范围内的全部32个探测器均显示故障",{"id":203,"libraryId":5,"type":84,"typeLabel":85,"stem":204,"options":205,"answer":216,"analysis":33},937060,"某建筑高度为23.8m的4层商业建筑，对其进行室内消火栓的配置和设计中，正确的有（ ）。",[206,208,210,212,214],{"key":20,"text":207,"correct":32},"选用DN65的室内消火栓",{"key":24,"text":209,"correct":22},"消火栓栓口动压大于0.5MPa",{"key":27,"text":211,"correct":32},"消火栓栓口动压不小于0.25MPa",{"key":30,"text":213,"correct":22},"配置直径65mm长30m的消防水带",{"key":97,"text":215,"correct":32},"水枪充实水柱不小于10m","ACE",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":20,"analysis":33},937061,"在对火灾自动报警控制器进行调试时，在完成主、备电源的自动转换后，应在备电工作状态检查控制器的负载功能。此时，控制器备用电源容量应能保证控制器在监视状态下工作8h后，尚应在负载功能试验期间工作（ ）min。",[221,223,225,227],{"key":20,"text":222,"correct":32},"30",{"key":24,"text":224,"correct":22},"60",{"key":27,"text":226,"correct":22},"90",{"key":30,"text":228,"correct":22},"120",{"id":230,"libraryId":5,"type":84,"typeLabel":85,"stem":231,"options":232,"answer":243,"analysis":33},937062,"下列关于室内消防管网及附件的叙述中，（ ）是错误的。",[233,235,237,239,241],{"key":20,"text":234,"correct":32},"厂房检修停止使用的消火栓不应超过5个",{"key":24,"text":236,"correct":32},"多层民用建筑室内消防给水管道上阀门的布置应保证检修管道时关闭的竖管不超过1根，但设置的竖管超过3根时，可关闭2根",{"key":27,"text":238,"correct":22},"高层住宅应保证检修管道时关闭停用的竖管不超过一根。当竖管超过4根时，可关闭不相邻的两根",{"key":30,"text":240,"correct":22},"高层公共建筑裙房内消防给水管道的阀门布置适用《建筑设计防火规范》",{"key":97,"text":242,"correct":32},"当室内消火栓给水管网与自动喷水合用消防泵时，供水管路沿水流方向应在报警阀后分开设置","ABE",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":27,"analysis":33},937063,"为保证点型感烟火灾探测器正常的使用功能，应定期对探测器进行清洗，若所安装的探测器产品说明书上无明确的清洗周期要求，则应每（ ）年清洗、标定一次。",[248,250,252,254],{"key":20,"text":249,"correct":22},"半年",{"key":24,"text":251,"correct":22},"一年",{"key":27,"text":253,"correct":32},"两年",{"key":30,"text":255,"correct":22},"三年",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":30,"analysis":33},937064,"根据《建筑消防设施的维护管理》GB 25201- 2010，下列不属于火灾报警控制器年度检测时应检测项目的是（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"火灾报警控制器的火警报警功能",{"key":24,"text":263,"correct":22},"火灾报警控制器的故障报警功能",{"key":27,"text":265,"correct":22},"火灾报警控制器的自检、消音功能",{"key":30,"text":267,"correct":32},"火灾报警控制器的最大负载能力",{"id":269,"libraryId":5,"type":84,"typeLabel":85,"stem":270,"options":271,"answer":282,"analysis":33},937065,"下列关于灭火器危险等级的相关的叙述中，错误的是（ ）。",[272,274,276,278,280],{"key":20,"text":273,"correct":22},"工业建筑与民用建筑配置灭火器危险等级类型是一致的",{"key":24,"text":275,"correct":32},"建筑物的灭火等级与其本身的耐火等级关系密切",{"key":27,"text":277,"correct":32},"专用电子计算机房的危险等级为中危险级",{"key":30,"text":279,"correct":22},"液化石油气储罐区的危险等级为严重危险级",{"key":97,"text":281,"correct":22},"中危险级指使用性质较重要，人员较密集，用电用火较多，可燃物较多，起火后蔓延较迅速，扑救较难的场所","BC",{"id":284,"libraryId":5,"type":84,"typeLabel":85,"stem":285,"options":286,"answer":297,"analysis":33},937066,"下列属于室内消火栓箱规定的是（ ）。",[287,289,291,293,295],{"key":20,"text":288,"correct":32},"阀门的设置位置应便于操作使用",{"key":24,"text":290,"correct":32},"不论消火栓箱的安装形式如何（明装、暗装、半暗装），不能影响疏散宽度",{"key":27,"text":292,"correct":32},"室内消火栓箱的安装应平正、牢固",{"key":30,"text":294,"correct":32},"暗装的消火栓箱不能破坏隔墙的耐火等级",{"key":97,"text":296,"correct":22},"当消火栓设置减压装置时，检查减压装置应符合设计要求","ABCD",{"id":299,"libraryId":5,"type":84,"typeLabel":85,"stem":300,"options":301,"answer":312,"analysis":33},937067,"灭火器配置场所的危险等级为严重危险级的是（ ）。",[302,304,306,308,310],{"key":20,"text":303,"correct":32},"某工厂的总控室和分控室",{"key":24,"text":305,"correct":22},"工业用燃油、燃气锅炉房",{"key":27,"text":307,"correct":22},"金属冶炼厂房",{"key":30,"text":309,"correct":32},"电影、电视摄影棚",{"key":97,"text":311,"correct":22},"民用燃油、燃气锅炉房","AD",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":30,"analysis":33},937068,"下列关于剩余电流探测器设置的说法，不正确的是（ ）。",[317,319,321,323],{"key":20,"text":318,"correct":22},"剩余电流式探测器负载侧的N线（即穿过探测器的工作零线）不应与其他回路共用",{"key":24,"text":320,"correct":22},"剩余电流式探测器负载侧的N线（即穿过探测器的工作零线）不能重复接地（即与PE线相连）",{"key":27,"text":322,"correct":22},"剩余电流式探测器不宜设置在IT系统的配电线路和消防配电线路中",{"key":30,"text":324,"correct":32},"剩余电流式探测器应设置在低压配电系统的首端，不应设置在除第一级配电箱外的其它配电箱上",{"id":326,"libraryId":5,"type":84,"typeLabel":85,"stem":327,"options":328,"answer":339,"analysis":33},937069,"灭火器配置场所的危险等级为中危险级的是（ ）。",[329,331,333,335,337],{"key":20,"text":330,"correct":32},"二类高层建筑的写字楼、公寓楼",{"key":24,"text":332,"correct":32},"百货楼、超市",{"key":27,"text":334,"correct":32},"民用燃气锅炉房",{"key":30,"text":336,"correct":22},"汽车加油站、加气站",{"key":97,"text":338,"correct":32},"地下汽车库","ABCE",{"id":341,"libraryId":5,"type":84,"typeLabel":85,"stem":342,"options":343,"answer":297,"analysis":33},937070,"对于灭火器的配置要求正确的是（ ）。",[344,346,348,350,352],{"key":20,"text":345,"correct":32},"一个计算单元内配置的灭火器数量不得少于2具",{"key":24,"text":347,"correct":32},"每个设置点的灭火器数量不宜多于5具",{"key":27,"text":349,"correct":32},"灭火器配置的设计与计算应按计算单元进行",{"key":30,"text":351,"correct":32},"每个灭火器设置点实配灭火器的灭火级别和数量不得小于最小需配灭火级别和数量的计算值",{"key":97,"text":353,"correct":22},"灭火器设置点的位置和数量应根据灭火器的最小保护距离确定，并应保证最不利点至少在1具灭火器的保护范围内",{"id":355,"libraryId":5,"type":84,"typeLabel":85,"stem":356,"options":357,"answer":339,"analysis":33},937071,"对泡沫灭火系统泡沫液的选择和储存说法正确的是（ ）。",[358,360,362,364,366],{"key":20,"text":359,"correct":32},"当采用液上喷射系统时，应选用蛋白、氟蛋白、成膜氟蛋白或水成膜泡沫液",{"key":24,"text":361,"correct":32},"当采用液下喷射系统时，应选用氟蛋白、成膜氟蛋白或水成膜泡沫液",{"key":27,"text":363,"correct":32},"用一套系统同时保护水溶性和非水溶性甲、乙、丙类液体的，必须选用抗溶泡沫液",{"key":30,"text":365,"correct":22},"用于油罐的中倍数泡沫灭火剂应采用专用6%型氟蛋白泡沫液",{"key":97,"text":367,"correct":32},"高倍数泡沫灭火系统利用热烟气发泡时，应采用耐温耐烟型高倍数泡沫液",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":27,"analysis":33},937072,"在进行周期性维护时，每季度应抽取不小于总数（ ）的消防电话和电话插孔在消防控制室进行对讲通话试验。",[372,374,376,378],{"key":20,"text":373,"correct":22},"10%",{"key":24,"text":375,"correct":22},"20%",{"key":27,"text":377,"correct":32},"25%",{"key":30,"text":379,"correct":22},"30%",{"id":381,"libraryId":5,"type":84,"typeLabel":85,"stem":382,"options":383,"answer":394,"analysis":33},937073,"下列关于市政消火栓系统设置，不正确的是（ ）。",[384,386,388,390,392],{"key":20,"text":385,"correct":32},"室外地下式有直径为100mm和65mm的栓口各一个，地下消火栓井的直径不宜小于1.0m",{"key":24,"text":387,"correct":32},"市政消火栓宜在道路的一侧设置，并宜靠近十字路口，每隔120~150米设置一个",{"key":27,"text":389,"correct":22},"市政消火栓应布置在消防车易于接近的人行道和绿地等地点距路边不宜小于0.5m，并不应大于2.0m，距建筑外墙或外墙边缘不宜小于5.0m",{"key":30,"text":391,"correct":32},"市政给水管网设有市政消火栓时，其平时运行工作压力不应小于0.14MPa，火灾时水力最不利市政消火栓的出流量不应小于10L\u002Fs",{"key":97,"text":393,"correct":32},"火灾时消防水鹤的出流量不宜低于30L\u002Fs，供水压力从地面算起不应小于0.15MPa","ABDE",{"id":396,"libraryId":5,"type":84,"typeLabel":85,"stem":397,"options":398,"answer":409,"analysis":33},937074,"下列关于自动喷水一泡沫联用系统设计的叙述中，正确的是（ ）。",[399,401,403,405,407],{"key":20,"text":400,"correct":22},"湿式系统自喷水至喷泡沫的转换时间，按61\u002Fs流量计算，不应大于3min",{"key":24,"text":402,"correct":32},"储罐区泡沫灭火系统扑救一次火灾的泡沫混合液设计用量，应按罐内用量、该罐辅助泡沫枪用量、管道剩余量三者之和最大的储罐确定",{"key":27,"text":404,"correct":32},"当储罐区固定式泡沫灭火系统的泡沫混合液流量大于或等于1001\u002Fs时，系统的泵、比例混合装置及其管道上的控制阀、干管控制阀宜具备远程控制功能",{"key":30,"text":406,"correct":22},"采用固定式泡沫灭火系统的储罐区，宜沿防火堤外均匀布置泡沫消火栓，且泡沫消火栓的间距不应大于65m",{"key":97,"text":408,"correct":32},"固定式泡沫灭火系统的设计应满足在泡沫消防水泵或泡沫混合液泵启动后，将泡沫混合液或泡沫输送到保护对像的时间不大于5min","BCE",{"id":411,"libraryId":5,"type":84,"typeLabel":85,"stem":412,"options":413,"answer":297,"analysis":33},937075,"下列宜增设一氧化碳火灾探测器实现火灾的早期探测的区域的（ ）。",[414,416,418,420,422],{"key":20,"text":415,"correct":32},"贮藏室",{"key":24,"text":417,"correct":32},"燃气供暖设备的机房",{"key":27,"text":419,"correct":32},"地下停车库",{"key":30,"text":421,"correct":32},"商场、超市",{"key":97,"text":423,"correct":22},"会议室",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":30,"analysis":33},937076,"下列关于消防给水系统架空管道支吊架安装要求的说法，不正确的是（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":22},"当管道穿梁安装时，穿梁处宜作为一个吊架",{"key":24,"text":431,"correct":22},"设计的吊架在管道的每一支撑点处应能承受5倍于充满水的管重，且管道系统支撑点应支撑整个消防给水系统",{"key":27,"text":433,"correct":22},"管道支架的支撑点宜设在建筑物的结构上，其结构在管道悬吊点应能承受充满水管道重量另加至少114kg的阀门、法兰和接头等附加荷载",{"key":30,"text":435,"correct":32},"防晃支架的强度，应满足管道、配件及管内水的重量再加30%的水平方向推力时不损坏或不产生永久变形",{"id":437,"libraryId":5,"type":84,"typeLabel":85,"stem":438,"options":439,"answer":450,"analysis":33},937077,"火灾探测器根据其监视范围不同可分为（ ）。",[440,442,444,446,448],{"key":20,"text":441,"correct":32},"点型",{"key":24,"text":443,"correct":32},"线型",{"key":27,"text":445,"correct":22},"面型",{"key":30,"text":447,"correct":22},"复合型",{"key":97,"text":449,"correct":22},"可拆卸型","AB",{"id":452,"libraryId":5,"type":84,"typeLabel":85,"stem":453,"options":454,"answer":297,"analysis":33},937078,"关于火灾探测器的选择，下列说法正确的是（ ）。",[455,457,459,461,463],{"key":20,"text":456,"correct":32},"对火灾初期有阴燃阶段，产生大量的烟和少量的热，很少或没有火焰辐射的场所，应选择感烟探测器",{"key":24,"text":458,"correct":32},"对火灾发展迅速，可产生大量热.烟和火焰辐射的场所，可选择感温探测器、感烟探测器、火焰探测器或其组合",{"key":27,"text":460,"correct":32},"对火灾发展迅速，有强烈的火焰辐射和少量的烟.热的场所，应选择火焰探测器",{"key":30,"text":462,"correct":32},"对火灾形成特征不可预料的场所，可根据模拟试验的结果选择探测器",{"key":97,"text":464,"correct":22},"对使用生产或聚集可燃气体或可燃液体蒸气的场所，宜增设一氧化碳火灾探测器",{"id":466,"libraryId":5,"type":84,"typeLabel":85,"stem":467,"options":468,"answer":479,"analysis":33},937079,"某大型石化储罐区设置外浮顶罐、内浮顶罐、固定顶罐和卧式罐。下列储罐中，储罐的通气管上必须设置阻火器的有（ ）。",[469,471,473,475,477],{"key":20,"text":470,"correct":22},"储存甘油的地上卧式罐",{"key":24,"text":472,"correct":22},"储存润滑油的地上固定顶罐",{"key":27,"text":474,"correct":32},"储存对二甲苯并采用氨气密封保护系统的内浮顶罐",{"key":30,"text":476,"correct":32},"储存重柴油的地上固定顶罐",{"key":97,"text":478,"correct":32},"储存二硫化碳的覆土式卧式罐","CDE",{"id":481,"libraryId":5,"type":84,"typeLabel":85,"stem":482,"options":483,"answer":494,"analysis":33},937080,"保护非水溶性液体的泡沫一水喷淋系统、泡沫枪系统、泡沫炮系统泡沫液的选择，当采用非吸气型喷射装置时，应选用（ ）。",[484,486,488,490,492],{"key":20,"text":485,"correct":22},"蛋白泡沫液",{"key":24,"text":487,"correct":22},"氟蛋白泡沫液",{"key":27,"text":489,"correct":32},"水成膜泡沫液",{"key":30,"text":491,"correct":32},"成膜氟蛋白泡沫液",{"key":97,"text":493,"correct":22},"抗溶性泡沫液","CD",{"id":496,"libraryId":5,"type":84,"typeLabel":85,"stem":497,"options":498,"answer":394,"analysis":33},937081,"下列（ ）场所宜选择点型感烟探测器是（ ）。",[499,501,503,505,507],{"key":20,"text":500,"correct":32},"计算机房",{"key":24,"text":502,"correct":32},"通讯机房",{"key":27,"text":504,"correct":22},"厨房",{"key":30,"text":506,"correct":32},"档案库",{"key":97,"text":508,"correct":32},"电影院",{"id":510,"libraryId":5,"type":84,"typeLabel":85,"stem":511,"options":512,"answer":339,"analysis":33},937082,"根据现行国家标准《火灾1刍动报警系统施工及验收规范》（GB50166），下列火灾自动报警系统的功能中，应每季度进行检查和试验的有（ ）。",[513,515,517,519,521],{"key":20,"text":514,"correct":32},"分期分批试验探测器的动作及确认灯显示功能",{"key":24,"text":516,"correct":32},"试验火灾警报装置的声、光显示功能",{"key":27,"text":518,"correct":32},"试验主、备电源自动切换功能",{"key":30,"text":520,"correct":22},"试验非消防电源强制切断功能",{"key":97,"text":522,"correct":32},"试验相关消防控制设备的控制显示功能",{"id":524,"libraryId":5,"type":84,"typeLabel":85,"stem":525,"options":526,"answer":339,"analysis":33},937083,"下列关于火灾自动报警系统设计的说法中不正确的是（ ）。",[527,529,531,533,535],{"key":20,"text":528,"correct":32},"任一台火灾报警控制器所连接的火灾探测器、手动火灾报警按钮和模块等设备总数和地址总数，均不应超过1600点",{"key":24,"text":530,"correct":32},"任一台消防联动控制器地址总数或火灾报警控制器（联动型）所控制的各类模块总数不应超过3200点",{"key":27,"text":532,"correct":32},"系统总线上应设置总线短路隔离器，每只总线短路隔离器保护的火灾探测器、手动火灾报警按钮和模块等消防设备的总数不应超过50点",{"key":30,"text":534,"correct":22},"水泵控制柜、风机控制柜等消防电气控制装置不应采用变频启动方式",{"key":97,"text":536,"correct":32},"每个报警区域内应均匀设置火灾警报器，其声压级不应小于65dB",{"id":538,"libraryId":5,"type":84,"typeLabel":85,"stem":539,"options":540,"answer":297,"analysis":33},937084,"（ ）等，宜作为备用消防水源使用。但当以上所列的水源必须作为消防水源时，应有保证在任何情况下都能满足消防给水系统所需的水量和水质的技术措施。",[541,543,545,547,549],{"key":20,"text":542,"correct":32},"雨水清水池",{"key":24,"text":544,"correct":32},"中水清水池",{"key":27,"text":546,"correct":32},"水景",{"key":30,"text":548,"correct":32},"游泳池",{"key":97,"text":550,"correct":22},"水井",{"id":552,"libraryId":5,"type":84,"typeLabel":85,"stem":553,"options":554,"answer":99,"analysis":33},937085,"下列关于火灾自动报警系统设备设置的说法中不正确是（ ）。",[555,557,559,561,563],{"key":20,"text":556,"correct":22},"火灾报警控制器和消防联动控制器安装在墙上时，其主显示屏高度宜为1.5m～1.8m",{"key":24,"text":558,"correct":32},"点型探测器至空调送风口边的水平距离不应小于Im，并宜接近回风口安装。探测器至多孔送风顶棚孔口的水平距离不应小于0.5m",{"key":27,"text":560,"correct":32},"手动火灾报警按钮应设置在明显和便于操作的部位。当采用壁挂方式安装时，其底边距地高度宜为1.1m～1.3m，且应有明显的标志",{"key":30,"text":562,"correct":32},"当火灾警报器采用壁挂方式安装时，其底边距地面高度应大于2m",{"key":97,"text":564,"correct":22},"壁挂扬声器的底边距地面高度应大于2.2m",{"id":566,"libraryId":5,"type":84,"typeLabel":85,"stem":567,"options":568,"answer":339,"analysis":33},937086,"下列场所应单独划分探测区域的是（ ）。",[569,571,573,575,577],{"key":20,"text":570,"correct":32},"敞开或封闭楼梯间、防烟楼梯间",{"key":24,"text":572,"correct":32},"防烟楼梯间前室、消防电梯前室、消防电梯与防烟楼梯间合用的前室",{"key":27,"text":574,"correct":32},"走道、坡道",{"key":30,"text":576,"correct":22},"电气管道井、通信管道井、消防电梯井道、电缆隧道",{"key":97,"text":578,"correct":32},"建筑物闷项、夹层",{"id":580,"libraryId":5,"type":84,"typeLabel":85,"stem":581,"options":582,"answer":297,"analysis":33},937087,"湿式系统和干式系统的联动控制设计时，（ ）的动作信号应反馈至消防联动控制器。",[583,585,587,589,591],{"key":20,"text":584,"correct":32},"水流指示器",{"key":24,"text":586,"correct":32},"信号阀",{"key":27,"text":588,"correct":32},"压力开关",{"key":30,"text":590,"correct":32},"喷淋消防泵的启动和停止的动作信号",{"key":97,"text":592,"correct":22},"末端试水装置",{"id":594,"libraryId":5,"type":84,"typeLabel":85,"stem":595,"options":596,"answer":99,"analysis":33},937088,"下列关于消防水源的维护管理的说法中，不正确的是（ ）。",[597,599,601,603,605],{"key":20,"text":598,"correct":22},"每年对水井等地下水消防水源的常水位、最低水位、最高水位和出水量等进行一次测定",{"key":24,"text":600,"correct":32},"每半年监测市政给水管网的压力和供水能力",{"key":27,"text":602,"correct":32},"每季度对消防水池、高位消防水池、高位消防水箱等消防水源设施的水位等进行一次检测",{"key":30,"text":604,"correct":32},"每天对消防储水设施进行室内温度和水温检测",{"key":97,"text":606,"correct":22},"永久性地表水天然水源消防取水口有防止水生生物繁殖的管理技术措施",{"id":608,"libraryId":5,"type":84,"typeLabel":85,"stem":609,"options":610,"answer":621,"analysis":33},937089,"下列场所中宜选择可燃气体探测器的是（ ）。",[611,613,615,617,619],{"key":20,"text":612,"correct":32},"使用可燃气体的场所",{"key":24,"text":614,"correct":32},"燃气站和燃气表房",{"key":27,"text":616,"correct":32},"散发可燃气体和可燃蒸气的场所",{"key":30,"text":618,"correct":22},"住宅厨房",{"key":97,"text":620,"correct":22},"柴油发电机房","ABC",{"id":623,"libraryId":5,"type":84,"typeLabel":85,"stem":624,"options":625,"answer":297,"analysis":33},937090,"下列关于消防控制室内设备布置中不符合相关规定的是（ ）。",[626,628,630,632,634],{"key":20,"text":627,"correct":32},"设备面盘前的操作距离单列布置时不应小于1m;双列布置时不应小于2m",{"key":24,"text":629,"correct":32},"在值班人员经常工作的一面，设备面盘至墙的距离不应小于2m",{"key":27,"text":631,"correct":32},"设备面盘后的维修距离不宜小于1.5m",{"key":30,"text":633,"correct":32},"设备面盘的排列长度大于4m时，其两端应设置宽度不小于1.2m的通道",{"key":97,"text":635,"correct":22},"与建筑其他弱电系统合用的消防控制室内，消防设备应集中设置",{"id":637,"libraryId":5,"type":84,"typeLabel":85,"stem":638,"options":639,"answer":174,"analysis":33},937091,"某单层洁净厂房，设有中央空调系统，用防火墙划分为两个防火分区，有一条输送带贯通两个防火分区，在输送带穿过防火墙的洞口设有专用防火闸门，厂房内设置IG541组合分配灭火系统保护。下列关于该气体灭火系统启动联动控制的说法中，正确的有（ ）。",[640,642,644,646,648],{"key":20,"text":641,"correct":32},"应联动关闭输送带穿过防火墙处的专用防火闸门",{"key":24,"text":643,"correct":32},"应联动关闭中央空调系统",{"key":27,"text":645,"correct":22},"应由一个火灾探测器动作启动系统",{"key":30,"text":647,"correct":32},"应联动打开气体灭火系统的选择阀",{"key":97,"text":649,"correct":22},"应联动打开空调系统穿越防火墙处的防火阀",{"id":651,"libraryId":5,"type":84,"typeLabel":85,"stem":652,"options":653,"answer":99,"analysis":33},937092,"某办公建筑设有自动喷水灭火系统、火灾自动报警系统和防排烟系统。建筑内下列消防系统中，启动联动控制不应受消防联动控制器处于自动或手动状态影响的有（ ）。",[654,656,658,660,662],{"key":20,"text":655,"correct":22},"预作用式自动喷水灭火系统",{"key":24,"text":657,"correct":32},"湿式自动喷水灭火系统",{"key":27,"text":659,"correct":32},"干式自动喷水灭火系统",{"key":30,"text":661,"correct":32},"湿式室内消火栓系统",{"key":97,"text":663,"correct":22},"防排烟系统",{"id":665,"libraryId":5,"type":84,"typeLabel":85,"stem":666,"options":667,"answer":678,"analysis":33},937093,"下列关于供水设施的维护管理规定，每季度应对消防水泵的（ ）进行一次试验。",[668,670,672,674,676],{"key":20,"text":669,"correct":32},"出流量",{"key":24,"text":671,"correct":22},"静压",{"key":27,"text":673,"correct":22},"功率",{"key":30,"text":675,"correct":22},"电压",{"key":97,"text":677,"correct":32},"压力","AE",{"id":680,"libraryId":5,"type":84,"typeLabel":85,"stem":681,"options":682,"answer":450,"analysis":33},937094,"预作用系统的联动控制设计时，手动控制方式，应将（ ），用专用线路直接连接至设置在消防控制室内的消防联动控制器的手动控制盘，直接手动控制喷淋消防泵的启动、停止及预作用阀组和电动阀的开启。",[683,685,687,688,690],{"key":20,"text":684,"correct":32},"喷淋消防泵控制箱（柜）的启动和停止按钮",{"key":24,"text":686,"correct":32},"预作用阀组和快速排气阀入口前的电动阀的启动和停止按钮",{"key":27,"text":586,"correct":22},{"key":30,"text":689,"correct":22},"快速排气阀入口前电动阀的动作信号",{"key":97,"text":588,"correct":22},{"id":692,"libraryId":5,"type":84,"typeLabel":85,"stem":693,"options":694,"answer":705,"analysis":33},937095,"气体灭火系统、泡沫灭火系统应分别由专用的气体灭火控制器、泡沫灭火控制器控制。气体灭火控制器、泡沫灭火控制器直接连接火灾探测器时，气体灭火系统、泡沫灭火系统的自动控制方式中联动控制信号应包括（ ）。",[695,697,699,701,703],{"key":20,"text":696,"correct":22},"启动设置在防护区入口处表示气体喷洒的火灾声光警报器",{"key":24,"text":698,"correct":32},"关闭防护区域的送（排）风机及送（排）风阀门",{"key":27,"text":700,"correct":32},"停止通风和空气调节系统及关闭设置在该防护区域的电动防火阀",{"key":30,"text":702,"correct":32},"联动控制防护区域开口封闭装置的启动，包括关闭防护区域的门、窗",{"key":97,"text":704,"correct":32},"启动气体灭火装置、泡沫灭火装置，气体灭火控制器、泡沫灭火控制器，可设定不大于30s的延迟喷射时间","BCDE",[707,710,713,716,719,722],{"id":15,"name":708,"category":7,"favorite":709},"领导干部任职前廉政法规知识测试题",92,{"id":711,"name":712,"category":7,"favorite":15},595,"建筑结构与设备",{"id":714,"name":715,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":717,"name":718,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":720,"name":721,"category":7,"favorite":8},534,"BIM工程师",{"id":723,"name":721,"category":7,"favorite":8},535]