[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-46":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":622},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,46,50,2974,[13,34,46,58,70,82,94,106,118,130,140,152,164,172,184,196,208,219,231,243,255,267,276,288,306,316,328,343,358,367,379,391,403,415,427,439,451,466,478,490,502,512,523,535,547,559,571,583,595,607],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},936945,1,"单选题","下列关于泡沫比例混合器安装要求的说法，正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","泡沫比例混合器（装置）的标注方向应与液流方向一致",true,{"key":24,"text":25,"correct":26},"B","备用的环泵式比例混合器应串联安装在系统上，并应有明显的标志",false,{"key":28,"text":29,"correct":26},"C","管线式比例混合器应安装在压力水的水平管道上并应远离储罐或防护区",{"key":31,"text":32,"correct":26},"D","压力式比例混合装置应分体安装，并应与基础牢固固定","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},936946,"用户信息传输装置在墙上安装时，正面操作距离不应小于（ ）m。",[38,40,42,44],{"key":20,"text":39,"correct":26},"0．5",{"key":24,"text":41,"correct":26},"1．0",{"key":28,"text":43,"correct":22},"1．2",{"key":31,"text":45,"correct":26},"1．5",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},936947,"城市消防远程监控系统竣工后，由（ ）负责组织相关单位进行工程检测。",[50,52,54,56],{"key":20,"text":51,"correct":26},"施工单位",{"key":24,"text":53,"correct":22},"建设单位",{"key":28,"text":55,"correct":26},"消防部门",{"key":31,"text":57,"correct":26},"质量监督站",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},936948,"对干粉灭火系统控制与操作不正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"干粉灭火系统应设有自动控制、手动控制和机械应急操作三种启动方式。当局部应用灭火系统用于经常有人的保护场所时可不设手动控制启动方式",{"key":24,"text":65,"correct":26},"设有火灾自动报警系统时，灭火系统的自动控制应在收到两个独立火灾探测信号后才能启动，并应延迟喷放",{"key":28,"text":67,"correct":26},"手动紧急停止装置应确保灭火系统能在启动后和喷放灭火剂前的延迟阶段中止。在使用手动紧急停止装置后，应保证手动启动装置可以再次启动",{"key":31,"text":69,"correct":26},"当采用气动动力源时，应保证系统操作与控制所需要的气体压力和用气量",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},936949,"线槽敷设时，应在（ ）部位设置吊点或支点。",[74,76,78,80],{"key":20,"text":75,"correct":26},"线槽中间及接头处",{"key":24,"text":77,"correct":26},"距接线盒1\u002F3m处",{"key":28,"text":79,"correct":22},"线槽转角或分支处",{"key":31,"text":81,"correct":26},"直线段不大于4m处",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},936950,"排烟管道设置在吊顶内时应采用不燃材料隔热，并应与可燃物保持不小于（ ）mm的距离。",[86,88,90,92],{"key":20,"text":87,"correct":26},"100",{"key":24,"text":89,"correct":22},"150",{"key":28,"text":91,"correct":26},"220",{"key":31,"text":93,"correct":26},"300",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},936951,"点型感温探测器宜水平安装，当确实需倾斜安装时，倾斜角不应大于（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"30°",{"key":24,"text":101,"correct":22},"45°",{"key":28,"text":103,"correct":26},"60°",{"key":31,"text":105,"correct":26},"90°",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},936952,"点型感烟、感温火灾探测器至墙壁、梁边的水平距离，不应小于（ ）m。",[110,112,114,116],{"key":20,"text":111,"correct":22},"0.5",{"key":24,"text":113,"correct":26},"1.5",{"key":28,"text":115,"correct":26},"0.2",{"key":31,"text":117,"correct":26},"3",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},936953,"下列关于气体灭火系统阀驱动装置安装的说法中，错误的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"安装以拉索式机械驱动装置时，应保证重物在下落行程中无阻挡，其下落行程应保证驱动所需距离，且不得小于25mm",{"key":24,"text":125,"correct":26},"电磁驱动装置驱动器的电气连接线应沿固定灭火剂储存容器的支、框架或墙面固定",{"key":28,"text":127,"correct":26},"气动驱动装置的管道安装后应做气压严密性试验，并合格",{"key":31,"text":129,"correct":26},"拉索式机械驱动装置的安装时拉索末端拉手应设在专用的保护盒内",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":28,"analysis":33},936954,"插座在潮湿场所安装时，应采用密封型并带保护地线触头的保护型插座，安装高度不低于（ ）m。",[134,136,137,138],{"key":20,"text":135,"correct":26},"1.0",{"key":24,"text":43,"correct":26},{"key":28,"text":45,"correct":22},{"key":31,"text":139,"correct":26},"1．8",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":33},936955,"某高度为120m的高层办公楼，其消防应急照明备用电源的连续供电时间不应低于（ ）mm。",[144,146,148,150],{"key":20,"text":145,"correct":22},"90",{"key":24,"text":147,"correct":26},"20",{"key":28,"text":149,"correct":26},"30",{"key":31,"text":151,"correct":26},"60",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":31,"analysis":33},936956,"消防电气控制装置在消防控制室内墙上安装时，其主显示屏高度宜为（ ）m。",[156,158,160,162],{"key":20,"text":157,"correct":26},"1.3～1.5",{"key":24,"text":159,"correct":26},"0.1～0.2",{"key":28,"text":161,"correct":26},"1～1.5",{"key":31,"text":163,"correct":22},"1.5~1.8",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":31,"analysis":33},936957,"某公共建筑和总建筑面积大于20000m2的地下、半地下建筑，其消防应急照明备用电源的连续供电时间不应低于（ ）min。",[168,169,170,171],{"key":20,"text":145,"correct":26},{"key":24,"text":147,"correct":26},{"key":28,"text":149,"correct":26},{"key":31,"text":151,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":20,"analysis":33},936958,"下列有关消防水泵调试的说法，错误的是（ ）。",[176,178,180,182],{"key":20,"text":177,"correct":22},"自动直接启动消防水泵时，消防水泵应在2min内投入正常运行，且应无不良噪声和振动",{"key":24,"text":179,"correct":26},"消防水泵的性能应与生产商提供的数据相符，并应满足设计流量和压力的要求",{"key":28,"text":181,"correct":26},"当出流量为设计工作流量的1．5倍时，其出口压力不应低于设计工作压力的0．65倍",{"key":31,"text":183,"correct":26},"消防水泵零流量时的压力不应超过设计工作压力的140％",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":31,"analysis":33},936959,"下列关于气体灭火系统控制组件安装的说法中，错误的是（ ）。",[188,190,192,194],{"key":20,"text":189,"correct":26},"防护区内火灾探测器的安装应符合国家标准《火灾自动报警系统施工及验收规范》GB 50166的规定",{"key":24,"text":191,"correct":26},"设置在防护区处的手动、自动转换开关应安装在防护区入口便于操作的部位，安装高度为中心点距地面1．5m",{"key":28,"text":193,"correct":26},"手动启动、停止按钮应安装在防护区入口便于操作的部位，安装高度为中心点距地面1．5m",{"key":31,"text":195,"correct":22},"气体喷放指示灯宜安装在防护区出口的正上方",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":31,"analysis":33},936960,"下列哪个建筑或场所（ ）。应在疏散走道和主要疏散路径的地面上增设能保持视觉连续的灯光疏散指示标志或蓄光疏散指示标志。",[200,202,204,206],{"key":20,"text":201,"correct":26},"总建筑面积为2000m2的机场候车厅",{"key":24,"text":203,"correct":26},"总建筑面积为5000m2的地上商店",{"key":28,"text":205,"correct":26},"总建筑面积为500m2的地下商店",{"key":31,"text":207,"correct":22},"总建筑面积为500m2的歌舞娱乐放映游艺场所",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},936961,"一栋综合楼，高60m，设有集中空调系统，地下一层为设备层，地下二层为汽车库，地上一至三层为商场，地上四层及以上是写字间。在计算室内消火栓系统消防用水量时，该建筑的火灾延续时间应按（ ）小时计算。",[212,214,216,217],{"key":20,"text":213,"correct":26},"1",{"key":24,"text":215,"correct":26},"2",{"key":28,"text":117,"correct":22},{"key":31,"text":218,"correct":26},"4",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":31,"analysis":33},936962,"基于细水雾灭火系统的灭火原理，下列场所中，细水雾灭火系统不适用于扑救的是（ ）。",[223,225,227,229],{"key":20,"text":224,"correct":26},"电缆夹层",{"key":24,"text":226,"correct":26},"柴油发电机房",{"key":28,"text":228,"correct":26},"锅炉房",{"key":31,"text":230,"correct":22},"电石仓库",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":24,"analysis":33},936963,"下列关于干粉灭火系统组成及其设置要求的说法中，不正确的是。",[235,237,239,241],{"key":20,"text":236,"correct":26},"储存装置的驱动气体应选用惰性气体，宜选用氮气",{"key":24,"text":238,"correct":22},"储存装置可设在耐火等级为三级的房间内",{"key":28,"text":240,"correct":26},"干粉储存容积设计压力可取1.6MPa或2.5MPa压力级",{"key":31,"text":242,"correct":26},"驱动压力不得大于干粉储存容器的最高工作压力。",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":28,"analysis":33},936964,"下列关于自然排烟的说法，错误的是（ ）。",[247,249,251,253],{"key":20,"text":248,"correct":26},"建筑面积为800m2的地下车库可采用自然排烟方式",{"key":24,"text":250,"correct":26},"防烟楼梯间及其前室应该设置防烟设施",{"key":28,"text":252,"correct":22},"防烟楼梯间及其前室不应采用自然排烟方式",{"key":31,"text":254,"correct":26},"建筑高度小于50m的公共建筑，宜优先考虑采用自然排烟方式",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":24,"analysis":33},936965,"用于灭火控火目的时，水雾喷头的工作压力不应小于（ ）。",[259,261,263,265],{"key":20,"text":260,"correct":26},"0.25MPa",{"key":24,"text":262,"correct":22},"0.35MPa",{"key":28,"text":264,"correct":26},"0.45MPa",{"key":31,"text":266,"correct":26},"0.55MPa",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":20,"analysis":33},936966,"在火灾突发的情况下，消防应急照明和疏散指示系统需要在极短的时间内实现应急转换，对于高危场所，应急转换时间不应超过（ ）s。",[271,273,274,275],{"key":20,"text":272,"correct":22},"0.25",{"key":24,"text":111,"correct":26},{"key":28,"text":213,"correct":26},{"key":31,"text":113,"correct":26},{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":24,"analysis":33},936967,"火灾自动报警系统对火灾声光警报器进行调试，逐一将火灾声光警报器与火灾报警控制器相连，接通电源。操作火灾报警控制器使火灾声光警报器启动，采用仪表测量其声压级，非住宅内使用室内型和室外型火灾声警报器的声信号至少在一个方向上3m处的声压级（A计权）应不小于（ ）d B，且在任意方向上3m处的声压级（A计权）应不大于120dB。",[280,282,284,286],{"key":20,"text":281,"correct":26},"65",{"key":24,"text":283,"correct":22},"75",{"key":28,"text":285,"correct":26},"85",{"key":31,"text":287,"correct":26},"95",{"id":289,"libraryId":5,"type":290,"typeLabel":291,"stem":292,"options":293,"answer":305,"analysis":33},936968,2,"多选题","下列关于水喷雾灭火系统喷头外观检查的说法，正确的是（）。",[294,296,298,300,302],{"key":20,"text":295,"correct":22},"商标、型号、制造厂及生产日期等标志齐全",{"key":24,"text":297,"correct":22},"喷头的型号、规格等符合设计要求",{"key":28,"text":299,"correct":22},"喷头外观无加工缺陷和机械损伤",{"key":31,"text":301,"correct":22},"喷头螺纹密封面应无伤痕、飞边、缺丝或断丝现象",{"key":303,"text":304,"correct":26},"E","应有水流方向的永久性标志","ABCD",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":20,"analysis":33},936969,"灭火器结构检查中，要求推车式灭火器的行驶机构完好，有足够的通过性能，推行时无卡阻，灭火器整体（轮子除外）最低位置与地面之间的间距不小于（ ）mm。",[310,311,313,314],{"key":20,"text":87,"correct":22},{"key":24,"text":312,"correct":26},"200",{"key":28,"text":93,"correct":26},{"key":31,"text":315,"correct":26},"400",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":20,"analysis":33},936970,"油浸变压器室、涡轮机房、柴油发电机房、润滑油站和燃油锅炉房、厨房内烹饪设备及其排烟罩和排烟管道部位可采用局部应用的细水雾开式系统。细水雾喷头的最低设计工作压力不应小于（ ）MPa。",[320,322,324,326],{"key":20,"text":321,"correct":22},"1.20",{"key":24,"text":323,"correct":26},"3.45",{"key":28,"text":325,"correct":26},"3.50",{"key":31,"text":327,"correct":26},"0.35",{"id":329,"libraryId":5,"type":290,"typeLabel":291,"stem":330,"options":331,"answer":342,"analysis":33},936971,"细水雾灭火系统工程质量缺陷可划分为严重缺陷项 （A）、一般缺陷项 （B）和轻度缺陷项 （C），按照规范规定下列选项可判定系统验收合格的是（ ）。",[332,334,336,338,340],{"key":20,"text":333,"correct":26},"A=1．且B=1，且C=1",{"key":24,"text":335,"correct":22},"A=0，且B=1，且C=3",{"key":28,"text":337,"correct":26},"A=0，且B=3，且C=2",{"key":31,"text":339,"correct":26},"A=1，且B=2，且C=0",{"key":303,"text":341,"correct":22},"A=0，且B=2，且C=2","BE",{"id":344,"libraryId":5,"type":290,"typeLabel":291,"stem":345,"options":346,"answer":357,"analysis":33},936972,"变、配电站（室）的设置正确的是（）。",[347,349,351,353,355],{"key":20,"text":348,"correct":26},"距甲、乙类厂房库房不应小于20m",{"key":24,"text":350,"correct":22},"距其他建筑物不应小于10m",{"key":28,"text":352,"correct":26},"距液化石油气罐不应小于25m",{"key":31,"text":354,"correct":22},"石油化工装置的变、配电室还应布置在装置的一侧，并位于爆炸危险区范围以外",{"key":303,"text":356,"correct":22},"距堆场、可燃液体储罐不应小于25m","BDE",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":33},936973,"点型感烟火灾探测器投入运行2年后，应每（ ）年至少全部清洗一遍。",[362,363,364,365],{"key":20,"text":215,"correct":22},{"key":24,"text":117,"correct":26},{"key":28,"text":218,"correct":26},{"key":31,"text":366,"correct":26},"5",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":20,"analysis":33},936974,"细水雾闭式系统喷头的感温组件与顶棚或梁底的距离（ ）。当场所内设置吊顶时，喷头可贴临吊顶布置。",[371,373,375,377],{"key":20,"text":372,"correct":22},"不宜小于75mm，并不宜大于150mm",{"key":24,"text":374,"correct":26},"不宜大于75mm",{"key":28,"text":376,"correct":26},"不宜小于150mm",{"key":31,"text":378,"correct":26},"宜等于150mm",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":381,"options":382,"answer":20,"analysis":33},936975,"某建筑高度为50m的宾馆，采用一路市政电源供电，柴油发电设备作为备用电源，建筑内的排烟风机采用主备电源自动切换装置。下列关于主备电源自动切换装置的设置中，不合理的是（ ）。",[383,385,387,389],{"key":20,"text":384,"correct":22},"自动切换装置设置在变电站内",{"key":24,"text":386,"correct":26},"自动切换装置设置在排烟风机房的风机控制配电箱内",{"key":28,"text":388,"correct":26},"主备电源自动切换时间为20s",{"key":31,"text":390,"correct":26},"主备电源自动切换时间为25s",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":24,"analysis":33},936976,"水雾喷头安装时，顶部设置的喷头应安装在被保护物的上部，室外安装坐标偏差不应大于（ ）mm，室内安装坐标偏差不应大于（ ）mm；标高的允许偏差，室外安装为±（ ）mm，室内安装为±（ ）mm。",[395,397,399,401],{"key":20,"text":396,"correct":26},"20，10，10，20",{"key":24,"text":398,"correct":22},"20，10，20，10",{"key":28,"text":400,"correct":26},"10，20，10，20",{"key":31,"text":402,"correct":26},"10，20，20，10",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":28,"analysis":33},936977,"细水雾灭火系统泵组供水装置，水泵控制柜（盘）应布置在干燥、通风的部位，便于操作和检修，其防护等级不应低于（ ）。",[407,409,411,413],{"key":20,"text":408,"correct":26},"IP65",{"key":24,"text":410,"correct":26},"IP68",{"key":28,"text":412,"correct":22},"IP54",{"key":31,"text":414,"correct":26},"IP55",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":28,"analysis":33},936978,"干粉灭火系统检查项目中，每日检查内容不包括（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":26},"干粉储存装置外观",{"key":24,"text":422,"correct":26},"灭火控制器运行情况",{"key":28,"text":424,"correct":22},"干粉储存装置部件",{"key":31,"text":426,"correct":26},"启动气体储瓶和驱动气体储瓶压力",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":31,"analysis":33},936979,"对水喷雾系统维保管理过程中，不正确的是（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":26},"每日应对阀门启闭状态进行检查",{"key":24,"text":434,"correct":26},"每周对消防水泵和备用动力进行一次启动试验",{"key":28,"text":436,"correct":26},"每季度应对系统进行一次放水试验",{"key":31,"text":438,"correct":22},"每年检查系统启动、报警功能以及出水情况是否正常",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":24,"analysis":33},936980,"某设置110个停车位的室内无车道且无人员停留的机械式地下汽车库，下列自动灭火系统中不适用于该车库的是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":26},"湿式自动喷水灭火系统",{"key":24,"text":446,"correct":22},"二氧化碳灭火系统",{"key":28,"text":448,"correct":26},"泡沫-水喷淋灭火系统",{"key":31,"text":450,"correct":26},"倍数泡沫灭火系统",{"id":452,"libraryId":5,"type":290,"typeLabel":291,"stem":453,"options":454,"answer":465,"analysis":33},936981,"下列（ ）建筑或场所（ ）。应在疏散走道和主要疏散路径的地面上增设能保持视觉连续的灯光疏散指示标志或蓄光疏散指示标志。",[455,457,459,461,463],{"key":20,"text":456,"correct":22},"总建筑面积为10000m2的展览建筑",{"key":24,"text":458,"correct":26},"总建筑面积为2000m2的地上超市",{"key":28,"text":460,"correct":22},"歌舞娱乐放映游艺场所",{"key":31,"text":462,"correct":26},"座位数超过1200个的电影院",{"key":303,"text":464,"correct":22},"建筑面积为5000m2的候车、候船厅","ACE",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":31,"analysis":33},936982,"下列概念的描述中，错误的是（ ）。",[470,472,474,476],{"key":20,"text":471,"correct":26},"泡沫液指可按适宜的混合比与水混合形成泡沫溶液的浓缩液体",{"key":24,"text":473,"correct":26},"泡沫混合液指泡沫液与水按特定混合比配制成的泡沫溶液",{"key":28,"text":475,"correct":26},"泡沫预混液指泡沫液与水按特定混合比预先配制成的储存待用的泡沫溶液",{"key":31,"text":477,"correct":22},"混合比指泡沫体积与形成该泡沫的泡沫混合液体积的比值",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},936983,"下列关于建筑室内消火栓设置的说法，错误的是（ ）。",[482,484,486,488],{"key":20,"text":483,"correct":26},"消防电梯前室应设置室内消火栓，并应计入消火栓使用数量",{"key":24,"text":485,"correct":22},"设置室内消火栓的建筑，层高超过2.2m的设备层宜设置室内消火栓",{"key":28,"text":487,"correct":26},"冷库的室内消火栓应设置在常温穿堂或楼梯间内",{"key":31,"text":489,"correct":26},"屋顶设置直升机停机坪的建筑，应在停机坪出入口设置消火栓",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":20,"analysis":33},936984,"下列关于湿式自动喷水灭火系统的描述中，正确的是（ ）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"准工作状态时管道内充满用于启动系统的有压水的闭式系统",{"key":24,"text":497,"correct":26},"准工作状态时管道内充满用于启动系统的有压气体的闭式系统",{"key":28,"text":499,"correct":26},"准工作状态时配水管道内不充水，由火灾报警系统自动开启预作用阀后，转换为湿式系统",{"key":31,"text":501,"correct":26},"采用开式喷头，由雨淋阀控制喷水范围，由配套的火灾自动报警系统或传动管系统启动雨淋阀",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":20,"analysis":33},936985,"某气体灭火系统储瓶间内设有4只同一规格的驱动气体储存容器，根据现行国家标准《气体灭火系统施工及验收规范》GB 50263—2007，该储存容器的高度差最大不宜超过（ ）mm。",[506,508,509,511],{"key":20,"text":507,"correct":22},"10",{"key":24,"text":149,"correct":26},{"key":28,"text":510,"correct":26},"50",{"key":31,"text":147,"correct":26},{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":24,"analysis":33},936986,"灭火器存在一定情形将予以报废，灭火器报废后，建筑使用管理单位按照等效替代的原则对灭火器进行更换。干粉灭火器、洁净气体灭火器出厂期满（ ）年予以报废。",[516,518,519,521],{"key":20,"text":517,"correct":26},"9",{"key":24,"text":507,"correct":22},{"key":28,"text":520,"correct":26},"11",{"key":31,"text":522,"correct":26},"12",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":28,"analysis":33},936987,"消防管道工程常用的连接方式有螺纹连接、焊接连接、法兰连接、承插连接、沟槽连接等形式。（ ）是将垫片放入一对固定在两个管口上的法兰的中间，用螺栓拉紧使其紧密结合起来的一种可拆卸的接头。",[527,529,531,533],{"key":20,"text":528,"correct":26},"螺纹连接",{"key":24,"text":530,"correct":26},"焊接连接",{"key":28,"text":532,"correct":22},"法兰连接",{"key":31,"text":534,"correct":26},"承插连接",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":20,"analysis":33},936988,"按照《泡沫灭火剂》（GB 15308—2006）和《泡沫灭火系统设计规范》（GB 50151—2010）的要求，下列泡沫灭火系统泡沫液需要送检的是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"6％型低倍数泡沫液设计用量大于或等于7．0t",{"key":24,"text":542,"correct":26},"3％型低倍数泡沫液设计用量小于3．5t",{"key":28,"text":544,"correct":26},"6％蛋白型中倍数泡沫液最小储备量小于2．5t",{"key":31,"text":546,"correct":26},"6％合成型中倍数泡沫液最小储备量小于2．0t",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":31,"analysis":33},936989,"排烟风机应保证在（ ）的环境条件下能连续工作不少于30min。",[551,553,555,557],{"key":20,"text":552,"correct":26},"100℃",{"key":24,"text":554,"correct":26},"200℃",{"key":28,"text":556,"correct":26},"250℃",{"key":31,"text":558,"correct":22},"280℃",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":20,"analysis":33},936990,"建筑高度不大于（ ）的住宅建筑，当有困难时，可采用干式消防竖管。",[563,565,567,569],{"key":20,"text":564,"correct":22},"27m",{"key":24,"text":566,"correct":26},"21m",{"key":28,"text":568,"correct":26},"54m",{"key":31,"text":570,"correct":26},"33m",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":28,"analysis":33},936991,"某一类高层办公楼的自备柴油发电机房，设置电动启动雨淋阀组的水喷雾灭火系统保护，当该系统的火灾探测装置动作后，打开雨淋报警阀组，压力开关动作，联锁启动消防水泵，水雾喷头灭火。该系统采用的火灾探测装置应是（ ）。",[575,577,579,581],{"key":20,"text":576,"correct":26},"气动传动管探测装置",{"key":24,"text":578,"correct":26},"液动传动管探测装置",{"key":28,"text":580,"correct":22},"感烟感温火灾探测装置",{"key":31,"text":582,"correct":26},"闭式喷头驱动传动管探测装置",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":31,"analysis":33},936992,"在低倍数泡沫灭火系统中，泡沫从储罐底部注入，并通过软管浮升到燃烧液体表面进行喷放的灭火系统是（ ）。",[587,589,591,593],{"key":20,"text":588,"correct":26},"固定式系统",{"key":24,"text":590,"correct":26},"半固定式系统",{"key":28,"text":592,"correct":26},"液下喷射系统",{"key":31,"text":594,"correct":22},"半液下喷射系统",{"id":596,"libraryId":5,"type":15,"typeLabel":16,"stem":597,"options":598,"answer":24,"analysis":33},936993,"下列关于架空管道支吊架安装要求的说法，不正确的是（ ）。",[599,601,603,605],{"key":20,"text":600,"correct":26},"管道支架的支撑点宜设在建筑物的结构上",{"key":24,"text":602,"correct":22},"配水管宜在中点设一个防晃支架，但当管径小于DN40时可不设",{"key":28,"text":604,"correct":26},"当管道穿梁安装时，穿梁处宜作为一个吊架",{"key":31,"text":606,"correct":26},"管径大于DN50的管道在拐弯处应设1个防晃支架",{"id":608,"libraryId":5,"type":290,"typeLabel":291,"stem":609,"options":610,"answer":621,"analysis":33},936994,"某商场共5层，每层划分为一个防火分区和三个防烟分区，商场内防烟排烟系统调试完成后进行验收，下列验收结果符合相关规范要求的有（ ）。",[611,613,615,617,619],{"key":20,"text":612,"correct":22},"活动挡烟垂壁下降到设计高度后能将状态信号反馈到消防控制室",{"key":24,"text":614,"correct":26},"开启某防烟分区内的全部排烟口，测试排烟口的风速为15m／s",{"key":28,"text":616,"correct":26},"测试系统的机械补风口的风速为10m／s",{"key":31,"text":618,"correct":22},"模拟三层发生火灾，该商场内全部的加压送机在规定的时间内动作",{"key":303,"text":620,"correct":22},"模拟某防烟分区内发生火灾，该防烟分区内的排烟口在规定的时间内全部被打开","ADE",[623,626,629,632,635,638],{"id":15,"name":624,"category":7,"favorite":625},"领导干部任职前廉政法规知识测试题",92,{"id":627,"name":628,"category":7,"favorite":15},595,"建筑结构与设备",{"id":630,"name":631,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":633,"name":634,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":636,"name":637,"category":7,"favorite":8},534,"BIM工程师",{"id":639,"name":637,"category":7,"favorite":8},535]