[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-45":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":639},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,45,50,2974,[13,34,52,64,79,94,106,118,130,142,157,169,181,193,205,220,232,246,258,270,285,297,309,321,333,348,360,372,382,394,406,415,427,435,449,461,472,484,496,508,520,532,544,556,568,580,592,604,616,627],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},936893,1,"单选题","有关系统设备检测数量要求正确的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","实际安装数量在10台以下者，全部检验",false,{"key":24,"text":25,"correct":22},"B","实际安装数量在6—10台者，抽验3台",{"key":27,"text":28,"correct":22},"C","实际安装数量超过10台者，按比例进行抽检，抽验总数不应少于3台",{"key":30,"text":31,"correct":32},"D","实际安装数量超过10台者，按实际安装数量30%~50%的比例抽验， 但抽验总数不应少于5台",true,"",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":51,"analysis":33},936894,2,"多选题","雨淋系统的联动控制设计时，联动控制方式，应由（ ）报警信号，作为雨淋阀组开启的联动触发信号。应由消防联动控制器控制雨淋阀组的开启",[40,42,44,46,48],{"key":20,"text":41,"correct":32},"同一报警区域内两只及以上独立的感温火灾探测器",{"key":24,"text":43,"correct":22},"同一报警区域内两只及以上独立的感烟火灾探测器",{"key":27,"text":45,"correct":22},"一只感烟火灾探测器与一只手动火灾报警按钮",{"key":30,"text":47,"correct":32},"一只感温火灾探测器与一只手动火灾报警按钮",{"key":49,"text":50,"correct":22},"E","同一报警区域内两只及以上独立的手动火灾报警按钮","AD",{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":24,"analysis":33},936895,"预作用系统配水管道内充有压气体的目的（ ）。",[56,58,60,62],{"key":20,"text":57,"correct":22},"将有压气体作为传递火警信号的介质",{"key":24,"text":59,"correct":32},"将有压气体作为检测管道的严密性介质",{"key":27,"text":61,"correct":22},"防止干式报警阀误动作",{"key":30,"text":63,"correct":22},"作为灭火用介质",{"id":65,"libraryId":5,"type":36,"typeLabel":37,"stem":66,"options":67,"answer":78,"analysis":33},936896,"在城市消防远程监控系统的调试中，属于监控中心端的系统调试的是（ ）。",[68,70,72,74,76],{"key":20,"text":69,"correct":22},"用户信息传输装置的调试",{"key":24,"text":71,"correct":32},"通信服务器的调试",{"key":27,"text":73,"correct":32},"信息查询系统的调试",{"key":30,"text":75,"correct":22},"火警信息终端的调试",{"key":49,"text":77,"correct":32},"用户服务系统的调试","BCE",{"id":80,"libraryId":5,"type":36,"typeLabel":37,"stem":81,"options":82,"answer":93,"analysis":33},936897,"在对火灾自动报警及消防联动控制系统进行验收前检测时，下列组件的抽检数量正确的有（ ）。",[83,85,87,89,91],{"key":20,"text":84,"correct":32},"火灾报警控制器共计2台，抽检2台",{"key":24,"text":86,"correct":32},"火灾探测器器共计3800只，抽检每个回路的10%～20%",{"key":27,"text":88,"correct":22},"区域显示器共计65台，抽检5台",{"key":30,"text":90,"correct":32},"电动防火门共计30樘，抽检6樘",{"key":49,"text":92,"correct":22},"自动喷水灭火系统上的水流指示器共计70只，抽检20只","ABD",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},936898,"在对可燃气体探测器进行调试时，对探测器施加达到响应浓度值的可燃气体标准样气，探测器应在（ ）s内响应。撤去可燃气体，探测器应在（ ）s内恢复到正常监视状态。",[98,100,102,104],{"key":20,"text":99,"correct":32},"30，60",{"key":24,"text":101,"correct":22},"60，60",{"key":27,"text":103,"correct":22},"60，30",{"key":30,"text":105,"correct":22},"30，30",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},936899,"在试验可燃气体报警控制器最大负载功能时，使至少（ ）只可燃气体探测器同时处于报警状态。",[110,112,114,116],{"key":20,"text":111,"correct":32},"4",{"key":24,"text":113,"correct":22},"5",{"key":27,"text":115,"correct":22},"10",{"key":30,"text":117,"correct":22},"50",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},936900,"住宅室内消火栓系统干式消防竖管的管径宜选择下列（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"DN100",{"key":24,"text":125,"correct":32},"DN80",{"key":27,"text":127,"correct":22},"DN65",{"key":30,"text":129,"correct":22},"DN50",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},936901,"自动喷水灭火系统喷头验收检查时，各种不同规格的喷头备用数量不少于安装喷头总数的（ ）%，且每种备用喷头不少于（ ）个。",[134,136,138,140],{"key":20,"text":135,"correct":32},"1，10",{"key":24,"text":137,"correct":22},"5，10",{"key":27,"text":139,"correct":22},"1，20",{"key":30,"text":141,"correct":22},"5，20",{"id":143,"libraryId":5,"type":36,"typeLabel":37,"stem":144,"options":145,"answer":156,"analysis":33},936902,"自动喷水灭火系统需要考虑消防排水措施的位置是（ ）。",[146,148,150,152,154],{"key":20,"text":147,"correct":32},"末端试水装置处",{"key":24,"text":149,"correct":22},"水流指示器处",{"key":27,"text":151,"correct":32},"报警阀处",{"key":30,"text":153,"correct":32},"减压阀处",{"key":49,"text":155,"correct":32},"消防水泵房内","ACDE",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":30,"analysis":33},936903,"自喷系统喷头安装时操作错误的是（ ）。",[161,163,165,167],{"key":20,"text":162,"correct":22},"安装在易受机械损伤处的喷头，应加设喷头防护罩",{"key":24,"text":164,"correct":22},"喷头安装应使用专用扳手，严禁利用喷头的框架施拧；喷头的框架、溅水盘产生变形或释放原件损伤时，应采用规格、型号相同的喷头更换",{"key":27,"text":166,"correct":22},"喷头安装时，不得对喷头进行拆装、改动，并严禁给喷头附加任何装饰性涂层",{"key":30,"text":168,"correct":32},"喷头安装后应对自喷系统进行试压和冲洗",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":30,"analysis":33},936904,"消防设施档案是建筑消防设施施工质量、维护管理的历史记录，具有延续性和可追溯性，是消防设施施工调试、操作使用、维护管理等状况的真实记录。下列不属于消防设施档案动态管理情况的是（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"值班记录",{"key":24,"text":176,"correct":22},"维护保养记录",{"key":27,"text":178,"correct":22},"值班人员基本情况档案",{"key":30,"text":180,"correct":32},"系统调试记录",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":27,"analysis":33},936905,"下列不属于消防产品一致性检查的步骤及要求的是（）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"逐一登记到场的各类消防设施的设备及其组件名称，批次,规格型号,数量和生产厂名，地址和产地等，与其设备清单、使用说明书等核对无误",{"key":24,"text":188,"correct":22},"查验各类消防设施的设备及其组件的规格型号及其数量、性能参数、生产厂名，以及地址与产地、标志、外观、材料、产品实物等，与经国家消防产品法定检验机构检验合格的型式检验报告一致",{"key":27,"text":190,"correct":32},"查验所有消防产品、管材管件、电缆电线以及其他设备、材料的出厂检验报告或出厂合格证",{"key":30,"text":192,"correct":22},"查验各类消防设施的设备及其组件规格型号，符合经法定机构批准或者备案的消防设计文件要求",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":24,"analysis":33},936906,"下列有关消防水泵接合器安装的说法，错误的是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"消火栓水泵接合器与消防通道之间不应设有妨碍消防车加压供水的障碍物",{"key":24,"text":200,"correct":32},"墙壁消防水泵接合器与墙面上的门、窗、孔、洞的净距离不应小于4．0m",{"key":27,"text":202,"correct":22},"地下消防水泵接合器的安装，应使进水口与井盖底面的距离不大于0．4m，且不应小于井盖的半径",{"key":30,"text":204,"correct":22},"消防水泵接合器永久性固定标志应能识别其所对应的消防给水系统或水灭火系统",{"id":206,"libraryId":5,"type":36,"typeLabel":37,"stem":207,"options":208,"answer":219,"analysis":33},936907,"根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列关于自动喷水灭火系统试压和冲洗的要求中，正确的是（ ）。",[209,211,213,215,217],{"key":20,"text":210,"correct":22},"管网冲洗应在试压合格后分段进行，冲洗顺序应先地下，后地上，先室内，后室外",{"key":24,"text":212,"correct":32},"强度试验和严密性试验宜用水进行",{"key":27,"text":214,"correct":22},"干式自动喷水灭火系统、预作用喷水灭火系统应做水压试验或气压试验",{"key":30,"text":216,"correct":32},"管网安装完毕后，必须对其进行强度试验、严密性试验和冲洗",{"key":49,"text":218,"correct":22},"管网冲洗应在试压合格后分段进行，室内部分的冲洗应按配水管、配水支管、配水干管的顺序进行","BD",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":27,"analysis":33},936908,"下列关于消防接口抗跌落性能检查的说法中，正确的是（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":22},"消防接口应从距混凝土地面（1．5±0．02）m高处（从接口的最低点算起）自由跌落，反复进行5次",{"key":24,"text":227,"correct":22},"消防接口应从距混凝土地面（2．0±0．02）m高处（从接口的最低点算起）自由跌落，反复进行3次",{"key":27,"text":229,"correct":32},"消防接口应从距混凝土地面（1．5±0．05）m高处（从接口的最低点算起）自由跌落，反复进行5次",{"key":30,"text":231,"correct":22},"消防接口应从距混凝土地面（2．0±0．05）m高处（从接口的最低点算起）自由跌落，反复进行3次",{"id":233,"libraryId":5,"type":36,"typeLabel":37,"stem":234,"options":235,"answer":51,"analysis":33},936909,"某消防工程施工单位对消火栓系统进行施工前的检查，对消火栓固定接口密封性做现场试验时，根据现行国家标准《消防给水及消防栓系统技术规范》GB 50974—2014规定，下列说法正确的是（ ）。",[236,238,240,242,244],{"key":20,"text":237,"correct":32},"试验数量宜从每批中抽查1％，但不应少于5个",{"key":24,"text":239,"correct":22},"当仅有1个不合格时，应再抽查2％，但不应少于5个",{"key":27,"text":241,"correct":22},"应缓慢而均匀地升压2．4MPa，应保压2min",{"key":30,"text":243,"correct":32},"当第2次抽查仍有不合格时，不应使用该批消火栓",{"key":49,"text":245,"correct":22},"需反复进行5次",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},936910,"下列关于自动喷水灭火系统周期性维护的说法中，不正确的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":32},"每天应检查储水设备的房间室温",{"key":24,"text":253,"correct":22},"每天应对水源控制阀、报警阀组进行外观检查，并应保证系统处于无故障状态",{"key":27,"text":255,"correct":22},"每月检查系统上所有的控制阀门均应采用铅封或锁链固定在开启或规定的状态",{"key":30,"text":257,"correct":22},"每月检查消防水池不被他用的技术措施",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":30,"analysis":33},936911,"下列关于报警阀密封性试验的说法，正确的是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"试验压力应为额定工作压力1．5倍的静水压力，保压时间不应小于2min",{"key":24,"text":265,"correct":22},"试验压力应为额定工作压力2倍的静水压力，保压时间不应小于2min",{"key":27,"text":267,"correct":22},"试验压力应为额定工作压力1．5倍的静水压力，保压时间不应小于5min",{"key":30,"text":269,"correct":32},"试验压力应为额定工作压力2倍的静水压力，保压时间不应小于5min",{"id":271,"libraryId":5,"type":36,"typeLabel":37,"stem":272,"options":273,"answer":284,"analysis":33},936912,"对自动喷水灭火系统的组件进行检查，根据现行国家标准《自动喷水灭火系统施工及验收规范》GB 50261—2017，下列关于系统组件的安装要求的说法中，正确的是（ ）。",[274,276,278,280,282],{"key":20,"text":275,"correct":32},"不应在倒流防止器的进口前安装过滤器",{"key":24,"text":277,"correct":32},"倒流防止器两端应分别安装闸阀",{"key":27,"text":279,"correct":32},"排气阀应安装在配水干管顶部、配水管的末端",{"key":30,"text":281,"correct":22},"水力警铃和报警阀的连接应采用热镀锌钢管，当镀锌钢管的公称直径为25mm时，其长度不宜大于20m",{"key":49,"text":283,"correct":22},"水流指示器应使电器元件部位水平安装在水平管道上侧，其动作方向应和水流方向一致","ABC",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":30,"analysis":33},936913,"下列关于细水雾灭火系统喷头安装的说法中，错误的是（ ）。",[289,291,293,295],{"key":20,"text":290,"correct":22},"根据设计文件逐个核对其生产厂标志、型号、规格和喷孔方向，不得对喷头进行拆装、改动",{"key":24,"text":292,"correct":22},"喷头安装应采用专用扳手安装",{"key":27,"text":294,"correct":22},"喷头安装高度、间距，与吊顶、门、窗、洞口、墙或障碍物的距离应符合设计要求",{"key":30,"text":296,"correct":32},"带有外置式过滤网的喷头，其过滤网应伸入支干管内",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":30,"analysis":33},936914,"对细水雾灭火系统进行气压试验时，不符合要求的做法是（ ）。",[301,303,305,307],{"key":20,"text":302,"correct":22},"试验介质为空气",{"key":24,"text":304,"correct":22},"干式系统的试验压力为0．28 MPa，且稳压24 h，压力降不大于0．01 MPa",{"key":27,"text":306,"correct":22},"预作用系统的试验压力为0．28 MPa，且稳压24 h，压力降不大于0．01 MPa",{"key":30,"text":308,"correct":32},"双流体系统气体管道的试验压力为水压强度试验压力的60％",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":24,"analysis":33},936915,"在对高倍数泡沫灭火系统功能验收时，要以手动或自动控制的方式对防护区进行喷泡沫试验，喷射泡沫的时间不小于（ ），实测泡沫混合液的混合比和泡沫供给速度，及自接到火灾模拟信号至开始喷泡沫的时间要符合设计要求。",[313,315,317,319],{"key":20,"text":314,"correct":22},"20s",{"key":24,"text":316,"correct":32},"30s",{"key":27,"text":318,"correct":22},"40s",{"key":30,"text":320,"correct":22},"50s",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":20,"analysis":33},936916,"下列关于干粉灭火系统组件的设置及选型说法错误的是（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":32},"喷放干粉时不能自动关闭的防护区开口其总面积不应大于该防护区总内表面积的10％",{"key":24,"text":328,"correct":22},"喷放后48h内不能恢复到正常工作状态时灭火剂应有备用量",{"key":27,"text":330,"correct":22},"全淹没灭火系统的干粉喷射时间不应大于30s",{"key":30,"text":332,"correct":22},"管道应采用无缝钢管，并在管网留有吹扫口",{"id":334,"libraryId":5,"type":36,"typeLabel":37,"stem":335,"options":336,"answer":347,"analysis":33},936917,"下列关于干粉灭火系统试压的说法中，正确的是（ ）。",[337,339,341,343,345],{"key":20,"text":338,"correct":22},"水压强度试验时，其测试点选择在系统管网的最高点",{"key":24,"text":340,"correct":22},"水压强度试验条件不具备时，可采用气密性试验代替",{"key":27,"text":342,"correct":32},"系统水压强度试验和严密性试验采用清水作为介质",{"key":30,"text":344,"correct":32},"水压强度试验压力为1．5倍系统最大工作压力",{"key":49,"text":346,"correct":32},"气压试验可采用试压装置进行试验，目测观察管网外观和测压用压力表","CDE",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":30,"analysis":33},936918,"在对建筑灭火器进行检查时，应注意检查灭火器箱与地面距离，根据现行国家消防技术标准，嵌墙式灭火器箱的安装高度应满足手提式灭火器顶部离地面距离不大于（ ）m。",[352,354,356,358],{"key":20,"text":353,"correct":22},"0．8",{"key":24,"text":355,"correct":22},"1．0",{"key":27,"text":357,"correct":22},"1．2",{"key":30,"text":359,"correct":32},"1．5",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":20,"analysis":33},936919,"下列灭火器中，需要进行报废处理的是（ ）。",[364,366,368,370],{"key":20,"text":365,"correct":32},"MS／Q9出厂后满6年",{"key":24,"text":367,"correct":22},"MF5出厂后满5年",{"key":27,"text":369,"correct":22},"MT5出厂后满10年",{"key":30,"text":371,"correct":22},"MF／ABC5出厂后满3年",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":27,"analysis":33},936920,"推车式灭火器喷射软管的长度（不包括软管两端的接头和喷射枪）不得小于（ ）m。",[376,378,380,381],{"key":20,"text":377,"correct":22},"2",{"key":24,"text":379,"correct":22},"3",{"key":27,"text":111,"correct":32},{"key":30,"text":113,"correct":22},{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":27,"analysis":33},936921,"对在同一配置单元内设置有两种类型的灭火器的场所进行验收检查时，下列检查结论中正确的是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，而且两种灭火剂的充装量相等，判定灭火器的配置合格",{"key":24,"text":389,"correct":22},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，而且两种灭火剂的类型不相容，判定灭火器的配置合格",{"key":27,"text":391,"correct":32},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，而且两种灭火剂的类型相容，判定灭火器的配置合格",{"key":30,"text":393,"correct":22},"核查灭火器的类型、数量、规格、灭火级别均符合设计要求，但两种灭火剂的充装量不相等，判定灭火器的配置不合格",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":24,"analysis":33},936922,"下列关于建筑内照明灯具防火措施检查的说法中，错误的是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"60W以上的白炽灯等高温照明灯具不应设置在火灾危险性场所",{"key":24,"text":401,"correct":32},"嵌入顶棚内的灯具，灯头引线应采用刚性金属管保护，其保护长度不宜超过1m",{"key":27,"text":403,"correct":22},"灯饰所用材料的燃烧性能等级不应低于B1级",{"key":30,"text":405,"correct":22},"霓虹灯与建筑物、构筑物表面距离不小于20mm",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":24,"analysis":33},936923,"消防应急照明灯具应均匀布置，最好安装在棚顶或距楼地面（ ）m以上的侧面墙上。",[410,412,413,414],{"key":20,"text":411,"correct":22},"1",{"key":24,"text":377,"correct":32},{"key":27,"text":379,"correct":22},{"key":30,"text":111,"correct":22},{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":27,"analysis":33},936924,"下列关于火灾自动报警系统的布线的说法中，不符合现行国家消防技术标准的是（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":22},"火灾自动报警系统的线路应单独布置",{"key":24,"text":422,"correct":22},"导线在管内或线槽内不应有接头或扭结",{"key":27,"text":424,"correct":32},"吊装线槽或管路的吊杆直径不应小于5mm",{"key":30,"text":426,"correct":22},"每个回路导线对地的绝缘电阻值不应小于20MΩ",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":27,"analysis":33},936925,"对应急照明系统控制器进行调试时，断开应急照明控制器的主电源，备用电源至少能保证应急照明控制器正常工作不应小于（ ）h。",[431,432,433,434],{"key":20,"text":411,"correct":22},{"key":24,"text":377,"correct":22},{"key":27,"text":379,"correct":32},{"key":30,"text":111,"correct":22},{"id":436,"libraryId":5,"type":36,"typeLabel":37,"stem":437,"options":438,"answer":284,"analysis":33},936926,"下列组件中，属于火灾探测报警系统组成部分的是（ ）。",[439,441,443,445,447],{"key":20,"text":440,"correct":32},"火灾声警报器",{"key":24,"text":442,"correct":32},"火灾报警按钮",{"key":27,"text":444,"correct":32},"火灾报警控制器",{"key":30,"text":446,"correct":22},"消防联动控制器",{"key":49,"text":448,"correct":22},"消防应急广播",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":27,"analysis":33},936927,"某金属加工厂的卷板车间安装有点型光电感烟火灾探测器，为适应产品结构转型将该车间改造为金属酸洗车间，之后车间内的点型光电感烟火灾探测器频频误报，最有可能的原因是（ ）。",[453,455,457,459],{"key":20,"text":454,"correct":22},"探测器产品质量不合格",{"key":24,"text":456,"correct":22},"探测器元件老化",{"key":27,"text":458,"correct":32},"金属酸洗车间内经常产生烟雾",{"key":30,"text":460,"correct":22},"电磁环境干扰",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":27,"analysis":33},936928,"监控中心与用户信息传输装置之间能够动态设置巡检方式和时间，要求通信巡检周期不大于（ ）min。",[465,466,468,470],{"key":20,"text":115,"correct":22},{"key":24,"text":467,"correct":22},"60",{"key":27,"text":469,"correct":32},"120",{"key":30,"text":471,"correct":22},"200",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":20,"analysis":33},936929,"灭火器使用一定年限后，对符合报废条件、报废年限的灭火器，建筑使用管理单位应及时采购符合要求的灭火器进行等效更换。下列灭火器中，正常情况下出厂时间已满6年可报废的是（ ）。",[476,478,480,482],{"key":20,"text":477,"correct":32},"水基型灭火器",{"key":24,"text":479,"correct":22},"洁净气体灭火器",{"key":27,"text":481,"correct":22},"干粉灭火器",{"key":30,"text":483,"correct":22},"二氧化碳灭火器",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":20,"analysis":33},936930,"下列关于干粉灭火系统管道气压强度试验的说法，不正确的是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":32},"气压强度试验压力取1.5倍系统最大工作压力",{"key":24,"text":491,"correct":22},"气压试验前，应用加压介质进行预试验，预试验压力为0.2MPa",{"key":27,"text":493,"correct":22},"当水压强度试验条件不具备时，可采用气压强度试验代替",{"key":30,"text":495,"correct":22},"试验时，逐步缓慢增加压力，当压力升至试验压力的50%时，如未发现异状或泄漏，继续按试验压力的10%逐级升压，每级稳压3min，直至达到试验压力",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":30,"analysis":33},936931,"下列关于干粉灭火系统维护管理的说法，不正确的是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"每日应检查启动气体储瓶和驱动气体储瓶压力",{"key":24,"text":503,"correct":22},"每月应检查驱动气体储瓶充装量",{"key":27,"text":505,"correct":22},"每年应检查防护区及干粉储存装置间",{"key":30,"text":507,"correct":32},"每季度应检查管网的支架及喷放组件",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":30,"analysis":33},936932,"下列关于气体灭火系统管道强度试验和气密性试验的说法，正确的是（ ）。",[512,514,516,518],{"key":20,"text":513,"correct":22},"管道进行气压强度试验时，当压力升至试验压力的50%时，如未发现异状或泄漏，继续按试验压力的10%逐级升压，每级稳压5min，直至试验压力",{"key":24,"text":515,"correct":22},"灭火剂输送管道气密性试验压力，应取水压强度试验压力的80%",{"key":27,"text":517,"correct":22},"管道进行气密性试验时，应以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力，关断试验气源30min内压力降不超过试验压力的10%为合格",{"key":30,"text":519,"correct":32},"进行水压强度试验时，以不大于0.5MPa\u002Fs的升压速率缓慢升压至试验压力，保压5min，检查管道各处无渗漏，无变形为合格",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":30,"analysis":33},936933,"下列关于气体灭火系统维护管理的说法，不正确的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"每日应对低压二氧化碳储存装置的运行情况进行检查并记录",{"key":24,"text":527,"correct":22},"每月应检查预制灭火系统的设备状态和运行状况",{"key":27,"text":529,"correct":22},"每季度应对可燃物的种类、分布情况，防护区的开口情况进行检查",{"key":30,"text":531,"correct":32},"每季度对每个防护区进行1次模拟启动试验",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},936934,"下列关于气体灭火系统维护管理的说法中，不正确的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":32},"气体灭火系统的储存容器应定期抽样送国家级消防产品检验中心检验",{"key":24,"text":539,"correct":22},"应按《压力容器安全技术监察规程》的规定对低压二氧化碳灭火系统的灭火剂储存容器进行维护管理",{"key":27,"text":541,"correct":22},"每季度应检查储存装置间的设备、灭火剂输送管道和支、吊架的固定，应无松动",{"key":30,"text":543,"correct":22},"高压二氧化碳灭火系统灭火剂储存容器内的压力不得小于设计储存容器的90%",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":30,"analysis":33},936935,"下列关于气体灭火系统组件安装要求的说法，不正确的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"气动驱动装置的竖直管道应在其始端和终端设防晃支架或采用管卡固定",{"key":24,"text":551,"correct":22},"气动驱动装置的水平管道应采用管卡固定，管卡的间距不宜大于0.6m",{"key":27,"text":553,"correct":22},"气动驱动装置的管道安装后应做气压严密性试验，并合格",{"key":30,"text":555,"correct":32},"安装以重力式机械驱动装置时，应保证重物在下落行程中无阻挡，其下落行程应保证驱动所需距离，且不得小于20mm",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":27,"analysis":33},936936,"防火防爆措施是综合性的措施，包括选用合理的电气设备，保持必要的防火间距，电气设备正常运行并有良好的通风，采用耐火设施，有完善的继电保护装置等技术措施。平面布置中，室外变、配电装置距液化石油气罐不应小于（ ）m。",[560,562,564,566],{"key":20,"text":561,"correct":22},"15",{"key":24,"text":563,"correct":22},"25",{"key":27,"text":565,"correct":32},"35",{"key":30,"text":567,"correct":22},"45",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":27,"analysis":33},936937,"防烟排烟系统安装前检查主要对系统组件、材料、设备到场后，对其外观、规格型号、基本性能、严密性等进行检查。下列不符合规定的是（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"有耐火极限要求的风管的本体、框架必须为不燃材料",{"key":24,"text":575,"correct":22},"有耐火极限要求的固定材料、密封垫料等必须为不燃材料",{"key":27,"text":577,"correct":32},"电动防火阀、送风口和排烟阀（口）的驱动装置，动作应可靠，在额定工作压力下工作正常",{"key":30,"text":579,"correct":22},"活动挡烟垂壁应符合有关消防产品标准的规定",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":30,"analysis":33},936940,"开门式灭火器箱的箱门关闭到位后，与四周框面平齐，与箱框之间的间隙均匀平直，不影响箱门开启。经游标卡尺实测检查，其箱门平面度误差不大于（ ），灭火器箱正面的零部件凸出箱门外表面高度不大于（ ），其他各面零部件凸出其外表面高度不大于（ ）；经塞尺实测检查，门与框最大间隙不超过（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":22},"2.5mm，15mm，10mm，2mm",{"key":24,"text":587,"correct":22},"2.5mm，10mm，15mm，2mm",{"key":27,"text":589,"correct":22},"2mm，10mm，15mm，2.5mm",{"key":30,"text":591,"correct":32},"2mm，15mm，10mm，2.5mm",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":30,"analysis":33},936941,"在消防给水系统中，能满足消防车的车载或手抬移动消防泵等取水所需要的工作压力和流量，管网内的压力较低，当火灾发生后，消防队员打开最近的室外消火栓，将消防车与室外消火栓连接，从室外管网内吸水加入消防车内，然后利用消防车直接加压灭火的系统是（ ）。",[596,598,600,602],{"key":20,"text":597,"correct":22},"高压消防给水系统",{"key":24,"text":599,"correct":22},"临时高压消防给水系统",{"key":27,"text":601,"correct":22},"干式消防竖管",{"key":30,"text":603,"correct":32},"低压消防给水系统",{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":24,"analysis":33},936942,"消防设施现场检查结束后，根据各类设施的施工及验收规范确定的工程施工质量缺陷类别（A为严重缺陷项，B为重缺陷项，C为轻缺陷项），按照规范要求对各类消防设施的施工质量作出验收判定结论，下列属于泡沫灭火系统验收标准的是()。",[608,610,612,614],{"key":20,"text":609,"correct":22},"当A=0，且B≤2，且B+C≤6时，竣工验收判定为合格，否则，竣工验收判定为不合格",{"key":24,"text":611,"correct":32},"当其功能验收不合格时，系统验收判定为不合格",{"key":27,"text":613,"correct":22},"当A=0,B≤2，且B+C≤检查项的5%时，竣工验收判定为合格，否则，竣工验收判定为不合格",{"key":30,"text":615,"correct":22},"当其验收项目有一项为不合格时，系统验收判定为不合格",{"id":617,"libraryId":5,"type":15,"typeLabel":16,"stem":618,"options":619,"answer":27,"analysis":33},936943,"水喷雾灭火系统的报警阀组距室内地面高度宜为（ ）m，正面与墙的距离不应小于（ ）m。",[620,622,624,626],{"key":20,"text":621,"correct":22},"1．3，0．5",{"key":24,"text":623,"correct":22},"1．2，1．0",{"key":27,"text":625,"correct":32},"1．2，1．2",{"key":30,"text":621,"correct":22},{"id":628,"libraryId":5,"type":15,"typeLabel":16,"stem":629,"options":630,"answer":24,"analysis":33},936944,"干粉灭火系统按照安装方式分，可分为（ ）。",[631,633,635,637],{"key":20,"text":632,"correct":22},"储气瓶型干粉灭火系统和储压型干粉灭火系统",{"key":24,"text":634,"correct":32},"固定式干粉灭火系统和半固定式干粉灭火系统",{"key":27,"text":636,"correct":22},"全淹没灭火系统和局部应用系统",{"key":30,"text":638,"correct":22},"管网干粉灭火系统、预制干粉灭火系统和干粉炮灭火系统",[640,643,646,649,652,655],{"id":15,"name":641,"category":7,"favorite":642},"领导干部任职前廉政法规知识测试题",92,{"id":644,"name":645,"category":7,"favorite":15},595,"建筑结构与设备",{"id":647,"name":648,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":650,"name":651,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":653,"name":654,"category":7,"favorite":8},534,"BIM工程师",{"id":656,"name":654,"category":7,"favorite":8},535]