[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-44":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":668},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,44,50,2974,[13,34,46,58,70,82,94,106,124,139,154,169,183,198,210,222,234,246,258,270,282,294,309,321,333,345,360,372,386,400,412,427,439,451,465,477,491,503,512,526,538,550,562,574,586,601,613,627,642,656],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},936843,1,"单选题","下列关于水喷雾灭火系统水雾喷头选型和设置要求的说法中，错误的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","扑灭电器火灾所选用离心雾化型水雾喷头",false,{"key":24,"text":25,"correct":22},"B","室内散发粉尘的场所设置的水雾喷头配带防尘帽",{"key":27,"text":28,"correct":22},"C","保护可燃气体储罐时，水雾喷头距离保护储罐外壁不应大于0.7m",{"key":30,"text":31,"correct":32},"D","保护油浸式变压器时，水雾喷头之间的水平距离与垂直距离不应大于1.2m",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},936844,"下列关于水喷雾系统的描述中，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"当自动水喷雾灭火系统误动作会对保护对象造成不利影响时，应采用两个独立火灾探测器的报警信号进行联锁控制",{"key":24,"text":41,"correct":22},"雨淋报警阀前的管道应设置可冲洗的过滤器",{"key":27,"text":43,"correct":32},"当响应时间大于120s时，水喷雾系统应具有自动控制、手动控制和应急机械启动三种控制方式",{"key":30,"text":45,"correct":22},"水雾喷头的工作压力，当用于灭火时不应小于0.35MPa",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},936845,"下列关于屋顶消防水箱的安装要求中，错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"无管道的侧面，净距不宜小于0.7m",{"key":24,"text":53,"correct":22},"安装有管道的侧面，净距不宜小于1.0m",{"key":27,"text":55,"correct":22},"管道外壁与建筑本体墙面之间的通道宽度不宜小于0.6m",{"key":30,"text":57,"correct":32},"水箱顶与其上面的建筑物本体板底的净空不应小于1.0m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},936846,"下列关于屋顶消防水箱的设置要求中，错误的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"安装无管道的侧面，净距0.8m",{"key":24,"text":65,"correct":22},"设有人孔的水箱顶面与建筑物本体板底的净空高度为0.8m",{"key":27,"text":67,"correct":22},"管道外壁与建筑本体墙面之间的通道宽度为0.8m",{"key":30,"text":69,"correct":32},"进水管充满水箱有效体积的时间为12h",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":30,"analysis":33},936847,"下列关于细水喷雾灭火系统联动控制的做法中，错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"开式系统在接收到两个不同类型的火灾报警信号后自动启动",{"key":24,"text":77,"correct":22},"开式系统在接收到两个独立回路中相同类型的两个火灾报警信号后自动启动",{"key":27,"text":79,"correct":22},"闭式系统在喷头动作后，由压力开关直接联锁自动启动",{"key":30,"text":81,"correct":32},"闭式系统在喷头动作后，由分区控制阀启闭信号自动启动",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},936848,"下列关于消防给水系统的叙述中，（ ）是错误的。",[86,88,90,92],{"key":20,"text":87,"correct":32},"建筑室外宜采用低压消防给水系统，室外消火栓应由市政给水管网直接供水",{"key":24,"text":89,"correct":22},"消防给水一起火灾灭火用水量应按需要同时作用的室内外消防给水用水量之和计算",{"key":27,"text":91,"correct":22},"一个建筑或构筑物的室外用水同时与室内用水开启使用，室内一个防护对象或防护区的消防用水量为消火栓用水、自动灭火用水、水幕或冷却分隔作用用水之和",{"key":30,"text":93,"correct":22},"人员密集的公共建筑应设置消防软管卷盘或轻便消防水龙，其设计流量可不计入消防给水设计流量",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":27,"analysis":33},936849,"下列关于消防联动控制设计相关要求的说法中错误的（ ）",[98,100,102,104],{"key":20,"text":99,"correct":22},"消防联动控制器应能按设定的控制逻辑向各相关的受控设备发出联动控制信号，并接受相关设备的联动反馈信号",{"key":24,"text":101,"correct":22},"各受控设备接口的特性详见数应与消防联动控制器发出的联动控制信号相匹配",{"key":27,"text":103,"correct":32},"消防水泵、防烟和排烟风机的控制设备，可以采用联动控制或在消防控制室设置手动直接控制装置",{"key":30,"text":105,"correct":22},"需要火灾自动报警系统联动控制的消防设备，其联动触发信号应采用两个独立的报警触发装置报警信号的“与”逻辑组合",{"id":107,"libraryId":5,"type":108,"typeLabel":109,"stem":110,"options":111,"answer":123,"analysis":33},936850,2,"多选题","下列关于消防配电电线电缆的选择及线路敷设的要求描述中，正确的是（ ）。",[112,114,116,118,120],{"key":20,"text":113,"correct":32},"火灾报警与消防联动控制系统的布线要选择铜芯绝缘电线或铜芯电缆",{"key":24,"text":115,"correct":32},"消防配电线路当采用矿物绝缘类不燃性电缆时，可直接明敷",{"key":27,"text":117,"correct":32},"消防配电消防配电干线宜按防火分区划分，消防配电支线不宜穿越防火分区，当跨越防火分区时应采取防止火灾延燃的措施",{"key":30,"text":119,"correct":22},"消防配电线路采用矿物绝缘类不燃性电缆时，不能与其他配电线路敷设在同一电缆井、沟内",{"key":121,"text":122,"correct":22},"E","配电电线电缆暗敷时，应穿管并应敷设在不燃性结构内且保护层厚度不应小于50mm","ABC",{"id":125,"libraryId":5,"type":108,"typeLabel":109,"stem":126,"options":127,"answer":138,"analysis":33},936851,"下列关于消防水泵设置及要求的说法中不正确的是（ ）。",[128,130,132,134,136],{"key":20,"text":129,"correct":32},"设置消防水泵时，必须设置备用泵",{"key":24,"text":131,"correct":32},"消防水泵的吸水口处必须设置旋流防止器",{"key":27,"text":133,"correct":22},"消防水泵应采取自灌式吸水",{"key":30,"text":135,"correct":32},"消防水泵从市政管网直接抽水时，应在消防水泵吸水管上设置有空气隔断的倒流防止器",{"key":121,"text":137,"correct":32},"当采用电动机驱动的消防水泵时，应选择电动机湿式安装的消防水泵","ABDE",{"id":140,"libraryId":5,"type":108,"typeLabel":109,"stem":141,"options":142,"answer":153,"analysis":33},936852,"下列关于消防水泵选用的说法中，正确的有（ ）。",[143,145,147,149,151],{"key":20,"text":144,"correct":22},"柴油机消防水泵应采用火花塞点火型柴油机",{"key":24,"text":146,"correct":32},"消防水泵流量一扬程性能曲线应光滑，无拐点，无驼峰",{"key":27,"text":148,"correct":22},"消防给水同一泵组的消防水泵型号应一致，且工作泵不宜超过5台",{"key":30,"text":150,"correct":32},"消防水泵泵轴的密封方式和材料应满足消防水泵在最低流量时运转的要求",{"key":121,"text":152,"correct":32},"电动机驱动的消防水泵时，应选择电动机干式安装的消防水泵","BDE",{"id":155,"libraryId":5,"type":108,"typeLabel":109,"stem":156,"options":157,"answer":168,"analysis":33},936853,"下列关于消防水池设计的叙述中，（ ）是正确的。",[158,160,162,164,166],{"key":20,"text":159,"correct":32},"储存室外消防用水的消防水池取水口的吸水高度不应大于6.0m",{"key":24,"text":161,"correct":22},"消防水池的补水时间不宜大于48h",{"key":27,"text":163,"correct":32},"消防用水与其它用水共用的水池，应采取确保消防用水量不作他用的技术措施",{"key":30,"text":165,"correct":22},"消防水池应设置呼吸管，呼吸管应采取防止虫鼠等进入消防水池的技术措施",{"key":121,"text":167,"correct":32},"消防水池进水管管径应经计算确定，且不应小于DN100","ACE",{"id":170,"libraryId":5,"type":108,"typeLabel":109,"stem":171,"options":172,"answer":138,"analysis":33},936854,"下列关于消防水池设置要求的说法中错误的是（ ）。",[173,175,177,179,181],{"key":20,"text":174,"correct":32},"消防水池进水管应根据其有效容积和补水时间确定，补水时间不宜超过24h",{"key":24,"text":176,"correct":32},"消防水池的总蓄水有效容积大于500m3时，宜设两座能独立使用的消防水池",{"key":27,"text":178,"correct":22},"消防水池应设置就地水位显示装置，并应在消防控制中心或值班室等地点设置显示消防水池水位的装置",{"key":30,"text":180,"correct":32},"消防水池应设置溢流水管和排水设施，并应采用直接排水",{"key":121,"text":182,"correct":32},"高位消防水池设置在建筑物内时，应采用耐火极限不低于2.50h的隔墙和1.50h的楼板与其他部位隔开",{"id":184,"libraryId":5,"type":108,"typeLabel":109,"stem":185,"options":186,"answer":197,"analysis":33},936855,"下列关于消防水箱的描述中错误的是（ ）。",[187,189,191,193,195],{"key":20,"text":188,"correct":32},"高层民用建筑、总建筑面积大于10000m2的公共建筑和其它重要建筑必须设置高位消防水箱",{"key":24,"text":190,"correct":22},"其它建筑设置消防水箱有困难，且采用安全可靠的消防给水形式时，可不设消防水箱，但应设稳压泵",{"key":27,"text":192,"correct":22},"设置高压给水系统的汽车库、修车库，当能保证最不利点消火栓和自动喷水灭火系统等的水量和水压时，可不设置消防水箱",{"key":30,"text":194,"correct":32},"设置临时高压消防给水系统的汽车库、修车库，应设置屋顶消防水箱，其容量不应小于6m3",{"key":121,"text":196,"correct":32},"高位消防水箱出水管管径应满足消防给水设计流量的出水要求且不应小于DN150","ADE",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":24,"analysis":33},936856,"下列关于消火栓系统联动控制设计的说法中错误的（ ）",[202,204,206,208],{"key":20,"text":203,"correct":22},"联动控制方式，可以由消火栓系统出水干管上设置的低压压力开关信号作为触发信号，直接控制启动消火栓泵",{"key":24,"text":205,"correct":32},"联动控制应受消防联动控制器处于自动或手动状态影响",{"key":27,"text":207,"correct":22},"消火栓按钮的动作信号应作为报警信号及启动消火栓泵的联动触发信号",{"key":30,"text":209,"correct":22},"手动控制方式，应将消火栓泵控制箱（柜）的启动、停止按钮用专用线路直接连接至设置在消防控制室内的消防联动控制器的手动控制盘，并应直接手动控制消火栓泵的启动、停止",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},936857,"下列关于自动喷水灭火系统的喷头选择叙述中，（ ）不正确。",[214,216,218,220],{"key":20,"text":215,"correct":22},"不做吊顶的场所可采用直立型喷头",{"key":24,"text":217,"correct":32},"设有自动喷水系统的房间，其吊顶内必须设喷头",{"key":27,"text":219,"correct":22},"宾馆客房、办公室可采用边墙型喷头",{"key":30,"text":221,"correct":22},"干式系统、预作用系统应采用直立型喷头或干式下垂型喷头",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":33},936858,"下列关于自动喷水灭火系统的说法中，错误的是（ ）。",[226,228,230,232],{"key":20,"text":227,"correct":32},"雨淋系统与预作用系统均采用开式洒水喷头",{"key":24,"text":229,"correct":22},"干式系统和预作用系统的配水管道应设置快速排气阀",{"key":27,"text":231,"correct":22},"雨淋系统应能由配套的火灾自动报警系统或传动管控制并启动雨淋报警阀",{"key":30,"text":233,"correct":22},"预作用系统应由火灾自动报警系统自动开启雨淋报警阀，并转换为湿式系统",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":27,"analysis":33},936859,"下列关于自动喷水湿式系统和干式系统的叙述中，（ ）是错误的。",[238,240,242,244],{"key":20,"text":239,"correct":22},"湿式系统一个报警阀组允许控制的喷头数比干式系统多",{"key":24,"text":241,"correct":22},"无论是湿式系统还是干式系统，当配水支管同时安装保护吊顶下方和上方空间的喷头时，应只将数量较多一侧的喷头计入报警阀组控制的喷头总数",{"key":27,"text":243,"correct":32},"湿式系统是准工作状态时配水管道内不充水，由火灾自动报警系统自动开启雨淋报警阀。",{"key":30,"text":245,"correct":22},"干式系统是准工作状态时管道内充满用于启动系统的有压气体的闭式系统",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":24,"analysis":33},936860,"下列关于自喷系统的叙述中，（ ）是错误的。",[250,252,254,256],{"key":20,"text":251,"correct":22},"作用面积指一次火灾中系统按喷水强度保护的最大面积",{"key":24,"text":253,"correct":32},"一只喷头的保护面积指其喷洒范围的水平投影面积，一般为圆形",{"key":27,"text":255,"correct":22},"净空高度8~12m的自选商场喷头最大间距为3m",{"key":30,"text":257,"correct":22},"民用建筑自喷系统最不利点处喷头的工作压力不应低于0.05MPa",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":20,"analysis":33},936861,"下列火灾中，不适合采用水喷雾进行灭火的是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":32},"樟脑油火灾",{"key":24,"text":265,"correct":22},"人造板火灾",{"key":27,"text":267,"correct":22},"电缆火灾",{"key":30,"text":269,"correct":22},"豆油火灾",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":24,"analysis":33},936862,"下列火灾中，可以采用IG541混合气体灭火剂扑救的是（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"硝化纤维、硝酸钠火灾",{"key":24,"text":277,"correct":32},"精密仪器火灾",{"key":27,"text":279,"correct":22},"钾、钠、镁火灾",{"key":30,"text":281,"correct":22},"联胺火灾",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":27,"analysis":33},936863,"下列建筑及设施中消防用电负荷应按二级负荷供电的是（ ）。：",[286,288,290,292],{"key":20,"text":287,"correct":22},"座位数1600个的体育馆",{"key":24,"text":289,"correct":22},"建筑高度24米的县级电信大楼",{"key":27,"text":291,"correct":32},"首层建筑面积4000m2的四层商业楼",{"key":30,"text":293,"correct":22},"24m的市公安厅办公楼",{"id":295,"libraryId":5,"type":108,"typeLabel":109,"stem":296,"options":297,"answer":308,"analysis":33},936864,"下列建筑物的消防用电设备应按二级负荷供电的是（ ）。",[298,300,302,304,306],{"key":20,"text":299,"correct":22},"高度超过50m的丙类厂房。",{"key":24,"text":301,"correct":32},"室外消防用水量超过25L\u002FS的多层办公楼",{"key":27,"text":303,"correct":32},"每层建筑面积为4000m2的多层百货楼",{"key":30,"text":305,"correct":32},"1600座的影剧院",{"key":121,"text":307,"correct":22},"建筑高度为60m的民用建筑","BCD",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":30,"analysis":33},936865,"下列建筑中，室内采用临时高压消防给水系统时，必须设置高位消防水箱的建筑是（ ）。",[313,315,317,319],{"key":20,"text":314,"correct":22},"建筑面积为5000m2的单层丙类厂房",{"key":24,"text":316,"correct":22},"建筑面积为40000m2的4层丁类厂房",{"key":27,"text":318,"correct":22},"建筑面积为5000m2的2层办公楼",{"key":30,"text":320,"correct":32},"建筑面积为30000㎡的3层商业中心",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":27,"analysis":33},936866,"下列建筑中的消防应急照明备用电源的连续供电时间按1.0h设置，其中不符合规范要求的是（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":22},"医疗建筑、老年人建筑",{"key":24,"text":328,"correct":22},"总建筑面积大于1OOOOOm2的商店建筑",{"key":27,"text":330,"correct":32},"建筑高度大于1OOm的住宅建筑",{"key":30,"text":332,"correct":22},"总建筑面积大于20000m2的地下汽车库",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":30,"analysis":33},936867,"下列建筑中消防用电负荷应按一级负荷供电的是（ ）。",[337,339,341,343],{"key":20,"text":338,"correct":22},"建筑面积4000m2的甲类厂房",{"key":24,"text":340,"correct":22},"建筑面积500m2甲类仓库",{"key":27,"text":342,"correct":22},"建筑高度为54米的住宅",{"key":30,"text":344,"correct":32},"建筑高度为32米门诊楼",{"id":346,"libraryId":5,"type":108,"typeLabel":109,"stem":347,"options":348,"answer":359,"analysis":33},936868,"下列某二类高层建筑写字楼按A类火灾场所设置灭火器的选择中，正确的是（ ）。",[349,351,353,355,357],{"key":20,"text":350,"correct":32},"设灭火级别为2A的手提式磷酸铵盐干粉灭火器，保护距离为20m",{"key":24,"text":352,"correct":22},"设灭火级别为IA的手提式磷酸铵盐干粉灭火器，保护距离为15m",{"key":27,"text":354,"correct":22},"设灭火级别为2A的手提式磷酸铵盐干粉灭火器，保护距离为40m",{"key":30,"text":356,"correct":32},"设灭火级别为2A的手提式磷酸铵盐干粉灭火器，保护距离为15m",{"key":121,"text":358,"correct":22},"设灭火级别为IA的手提式磷酸铵盐干粉灭火器，保护距离为12m","AD",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":27,"analysis":33},936869,"下列哪个场所可以不设置火灾自动报警系统（ ）",[364,366,368,370],{"key":20,"text":365,"correct":22},"总建筑面积为3200m2的玩具生产厂房",{"key":24,"text":367,"correct":22},"总建筑面积为1OOOm2的地下商店",{"key":27,"text":369,"correct":32},"座位数为1500的会堂",{"key":30,"text":371,"correct":22},"建筑高度为120米的住宅",{"id":373,"libraryId":5,"type":108,"typeLabel":109,"stem":374,"options":375,"answer":197,"analysis":33},936870,"下列汽车库、修车库、停车场中，可不设置自动喷水灭火系统的有（ ）。",[376,378,380,382,384],{"key":20,"text":377,"correct":32},"Ⅳ类地上汽车库",{"key":24,"text":379,"correct":22},"机械式汽车库",{"key":27,"text":381,"correct":22},"Ⅰ类汽车库",{"key":30,"text":383,"correct":32},"屋面停车场",{"key":121,"text":385,"correct":32},"停车数量为10辆的地下停车库",{"id":387,"libraryId":5,"type":108,"typeLabel":109,"stem":388,"options":389,"answer":308,"analysis":33},936871,"下列细水雾系统的设计持续喷雾时间符合规定的是（ ）。",[390,392,394,396,398],{"key":20,"text":391,"correct":22},"用于保护柴油发电机房时，系统的设计持续喷雾时间不应小于30min",{"key":24,"text":393,"correct":32},"用于保护配电室等电子、电气设备间时，系统的设计持续喷雾时间不应小于30min",{"key":27,"text":395,"correct":32},"用于扑救厨房内烹饪设备及其排烟罩和排烟管道部位的火灾时，系统的设计持续喷雾时间不应小于15s，设计冷却时间不应小于15min",{"key":30,"text":397,"correct":32},"对于瓶组系统，系统的设计持续喷雾时间最小不宜小于10min",{"key":121,"text":399,"correct":22},"用于保护燃油锅炉房时，系统的设计持续喷雾时间不应小于30min",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":24,"analysis":33},936872,"下列消防用水水源的叙述中，正确的是（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":22},"消防用水只能由城市给水管网、消防水池供给",{"key":24,"text":407,"correct":32},"消防用水可由保证率≥97%，且设有可靠取水设施的天然水源供给",{"key":27,"text":409,"correct":22},"当井水作为消防水源时，可以不设置探测水井水位的水位测试装置",{"key":30,"text":411,"correct":22},"消防用水不能由天然水源供给",{"id":413,"libraryId":5,"type":108,"typeLabel":109,"stem":414,"options":415,"answer":426,"analysis":33},936873,"下列选项中应分区供水的是（ ）。",[416,418,420,422,424],{"key":20,"text":417,"correct":32},"系统工作压力大于2.40MPa",{"key":24,"text":419,"correct":32},"消火栓栓口处静压大于1.0MPa",{"key":27,"text":421,"correct":32},"自动水灭火系统报警阀处的工作压力大于1.60MPa",{"key":30,"text":423,"correct":22},"消火栓栓口动压大于0.70MPa",{"key":121,"text":425,"correct":32},"喷头处的工作压力大于1.20MPa","ABCE",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":24,"analysis":33},936874,"下列有关火灾自动报警系统布线的做法，不正确的是（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":22},"从接线盒引到探测器底座盒的线路，加金属软管保护",{"key":24,"text":434,"correct":32},"在建筑抹灰及地面工程结束前完成了管内布线",{"key":27,"text":436,"correct":22},"导线的接头，在接线盒内焊接",{"key":30,"text":438,"correct":22},"金属管子进入接线盒时，线盒外侧套锁母，内侧装护口",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":27,"analysis":33},936875,"下列自动喷水灭火系统关于控制方式中说法错误的是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"湿式系统、干式系统的喷头动作后，应由压力开关直接连锁自动启动供水泵",{"key":24,"text":446,"correct":22},"预作用系统、雨淋系统及自动控制的水幕系统，应在火灾报警系统报警后，立即自动向配水管道供水",{"key":27,"text":448,"correct":32},"干式、预作用系统中，有压充气管道快速排气阀入口前的电动阀，应在启动供水泵之前开启排气，以便于供水泵启动后能快速充水",{"key":30,"text":450,"correct":22},"湿式系统、干式系统应在开放一只喷头后自动启动",{"id":452,"libraryId":5,"type":108,"typeLabel":109,"stem":453,"options":454,"answer":123,"analysis":33},936876,"下列自动喷水灭火系统组件与设施的连接管中，管径不应小于DN25的是（ ）。",[455,457,459,461,463],{"key":20,"text":456,"correct":32},"与DN15直立型喷头连接的短立管",{"key":24,"text":458,"correct":32},"与DN15下垂型喷头连接的短立管",{"key":27,"text":460,"correct":32},"末端试水装置的连接管",{"key":30,"text":462,"correct":22},"水力警铃与报警阀间的连接管",{"key":121,"text":464,"correct":22},"干式系统、预作用系统的供气管道",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":24,"analysis":33},936877,"消防技术服务机构对某单位疏散走道上设置的常开防火门进行联动调试，下列说法不正确的是（ ）。",[469,471,473,475],{"key":20,"text":470,"correct":22},"触发防火门所在防火分区内的两只独立的火灾探测器，消防联动控制器应能发出防火门关闭的控制信号",{"key":24,"text":472,"correct":32},"电动闭门器接收到关闭信号后，应在25s内执行启动信号，点亮启动总指示灯",{"key":27,"text":474,"correct":22},"使防火门处于半开闭状态时，防火门监控器故障指示灯应点亮并发出声光报警信号，声信号的声压级（正前方1m处），应在65dB~85dB之间",{"key":30,"text":476,"correct":22},"断开防火门监控器的主电源，应能自动转换至备用电源供电，转换过程中应不使监控器发生误动作",{"id":478,"libraryId":5,"type":108,"typeLabel":109,"stem":479,"options":480,"answer":359,"analysis":33},936878,"消防水泵驱动器宜采用（ ）驱动方式。",[481,483,485,487,489],{"key":20,"text":482,"correct":32},"采用电动机直接传动",{"key":24,"text":484,"correct":22},"采用基于柴油机组成的双动力驱动",{"key":27,"text":486,"correct":22},"采用双电动机组成的双动力驱动",{"key":30,"text":488,"correct":32},"采用柴油机直接传动",{"key":121,"text":490,"correct":22},"采用柴油机间接传动",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":24,"analysis":33},936879,"消防应急标志灯具低位安装在疏散走道及其转角处时，应安装在距地面（ ）m以下的墙上，标志表面应与墙面平行，凸出墙面的部分不应有尖锐角及伸出的固定件。",[495,497,499,501],{"key":20,"text":496,"correct":22},"0.5",{"key":24,"text":498,"correct":32},"1.0",{"key":27,"text":500,"correct":22},"1.5",{"key":30,"text":502,"correct":22},"2.0",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":33},936880,"消防应急电源调试中，切断应急电源应急输出时直接启动设备的连线，接通应急电源的主电源。将应急电源接上等效于满负载的模拟负载，使其处于应急工作状态，应急工作时间应大于设计应急工作时间的（ ）倍，且不小于产品标称的应急工作时间。",[507,508,509,510],{"key":20,"text":498,"correct":22},{"key":24,"text":500,"correct":32},{"key":27,"text":502,"correct":22},{"key":30,"text":511,"correct":22},"2.5",{"id":513,"libraryId":5,"type":108,"typeLabel":109,"stem":514,"options":515,"answer":123,"analysis":33},936881,"消火栓系统的联动控制设计时，联动控制方式，应由（ ）等信号作为触发信号，直接控制启动消火栓泵，联动控制不应受消防联动控制器处于自动或手动状态影响。",[516,518,520,522,524],{"key":20,"text":517,"correct":32},"消火栓系统出水干管上设置的压力开关",{"key":24,"text":519,"correct":32},"高位消防水箱出水管上设置的流量开关",{"key":27,"text":521,"correct":32},"或报警阀压力开关",{"key":30,"text":523,"correct":22},"一只感温火灾探测器与一只手动火灾报警按钮",{"key":121,"text":525,"correct":22},"同一报警区域内两只及以上独立的水枪",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":27,"analysis":33},936882,"消火栓系统在进场检验、施工及调试验收过程中对消防组件的性能详见数要求，下列说法中错误的是（ ）",[530,532,534,536],{"key":20,"text":531,"correct":22},"进场检验时流量开关应能在管道流速为0.1m\u002Fs~10m\u002Fs时可靠启动",{"key":24,"text":533,"correct":22},"消防水泵出水管上压力表量程在没有设计要求时，应为系统工作压力的2倍~2.5倍",{"key":27,"text":535,"correct":32},"系统试压时试压用的压力表不应少于2只；精度不应低于1.5级，量程应为试验压力值的2倍~2.5倍",{"key":30,"text":537,"correct":22},"消防水泵零流量时的压力不应超过设计工作压力的140%;当出流量为设计工作流量的150%时，其出口压力不应低于设计工作压力的65%",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":20,"analysis":33},936883,"新建一个内浮顶原油储罐，容量为6000m3，采用中倍数泡沫灭火系统时，宜选用（ ）泡沫灭火系统。",[542,544,546,548],{"key":20,"text":543,"correct":32},"固定",{"key":24,"text":545,"correct":22},"移动",{"key":27,"text":547,"correct":22},"半固定",{"key":30,"text":549,"correct":22},"半移动",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":20,"analysis":33},936884,"液下喷射式泡沫灭火系统适用于（ ）。",[554,556,558,560],{"key":20,"text":555,"correct":32},"烃类液体固定顶储罐",{"key":24,"text":557,"correct":22},"外浮项储罐",{"key":27,"text":559,"correct":22},"内浮顶储罐",{"key":30,"text":561,"correct":22},"水溶性甲乙丙类液体储罐",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":27,"analysis":33},936885,"一栋20层的建筑，底部四层为商业裙房，每层建筑面积3000㎡，5层及以上为住宅，设置临时高压消防给水系统，则高位水箱有效容积不应小于（ ）。",[566,568,570,572],{"key":20,"text":567,"correct":22},"12m3",{"key":24,"text":569,"correct":22},"18m3",{"key":27,"text":571,"correct":32},"36m3",{"key":30,"text":573,"correct":22},"50m3",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":27,"analysis":33},936886,"一座单层摄影棚，净空高度为7.8m，建筑面积10400m2，其中自动喷水灭火湿式系统保护面积为2600m2，布置闭式洒水喷头300个；雨淋系统保护面积为7800m2，布置开式洒水喷头890个，则按规定应设置（ ）组雨淋阀。",[578,580,582,584],{"key":20,"text":579,"correct":22},"2组",{"key":24,"text":581,"correct":22},"3组",{"key":27,"text":583,"correct":32},"30组",{"key":30,"text":585,"correct":22},"40组",{"id":587,"libraryId":5,"type":108,"typeLabel":109,"stem":588,"options":589,"answer":600,"analysis":33},936887,"以下（ ）建筑内设置的高位消防水箱最低水位应维持最不利点处的静水压力不低于0.10MPa。",[590,592,594,596,598],{"key":20,"text":591,"correct":32},"市级建筑高度58m的政府机关办公楼",{"key":24,"text":593,"correct":22},"建筑高度为150m的住宅建筑",{"key":27,"text":595,"correct":32},"建筑体积为25000m3的厂房",{"key":30,"text":597,"correct":22},"建筑高度为120m的公寓",{"key":121,"text":599,"correct":22},"建筑体积为15000m3的仓库","AC",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":30,"analysis":33},936888,"以下关于报警阀及末端试水装置的说法（ ）错误。",[605,607,609,611],{"key":20,"text":606,"correct":22},"报警阀组控制的喷头只保护不超过防火分区面积的同层场所，可不设水流指示器",{"key":24,"text":608,"correct":22},"末端试水装置测试的内容，包括水流指示器、报警阀、压力开关、水力警铃",{"key":27,"text":610,"correct":22},"安装试水阀是为了在必要时连接末端试水装置",{"key":30,"text":612,"correct":32},"并联设置雨淋阀组的雨淋系统，其雨淋阀控制腔的入口应设置倒流防止器",{"id":614,"libraryId":5,"type":108,"typeLabel":109,"stem":615,"options":616,"answer":123,"analysis":33},936889,"以下关于屋顶消防水箱设置的叙述中，错误的有（ ）。",[617,619,621,623,625],{"key":20,"text":618,"correct":32},"高层建筑必须设置屋顶消防水箱",{"key":24,"text":620,"correct":32},"对仅设置室内消火栓系统的高层工业厂房，当必须设置屋顶消防水箱时，消防水箱设置在该厂房的最高部位",{"key":27,"text":622,"correct":32},"屋顶消防水箱的设置高度应满足室内最不利点处消火栓灭火时的计算压力",{"key":30,"text":624,"correct":22},"屋顶消防水箱的主要作用是提供初期火灾时的消防用水水量",{"key":121,"text":626,"correct":22},"总建筑面积大于10000㎡且层数超过2层的公共建筑必须设置高位消防水箱",{"id":628,"libraryId":5,"type":108,"typeLabel":109,"stem":629,"options":630,"answer":641,"analysis":33},936890,"以下关于消防泵的选择和应用的说法中不正确的是（ ）。",[631,633,635,637,639],{"key":20,"text":632,"correct":32},"驱动器的功率应满足所选水泵流量扬程性能曲线上实际运行高效段所需功率的要求",{"key":24,"text":634,"correct":22},"零流量时的压力不应大于设计工作压力的140%，且宜大于设计工作压力的120%",{"key":27,"text":636,"correct":32},"当出流量为设计流量的150%时，其出口压力不应低于设计工作压力的85%",{"key":30,"text":638,"correct":32},"泵轴的密封方式和材料应满足消防水泵在高流量时运转的要求",{"key":121,"text":640,"correct":32},"防给水同一泵组的消防水泵型号宜一致，且工作泵不宜超过5台","ACDE",{"id":643,"libraryId":5,"type":108,"typeLabel":109,"stem":644,"options":645,"answer":426,"analysis":33},936891,"用于消防电梯火灾时，消防备用电源持续运行时间应大于消防水泵、水幕泵火灾时的持续运行时间；下列（ ）需要消防备用电源持续时间大于60min。",[646,648,650,652,654],{"key":20,"text":647,"correct":32},"建筑高度大于100米的民用建筑加压风机",{"key":24,"text":649,"correct":32},"医疗建筑",{"key":27,"text":651,"correct":32},"老年人建筑",{"key":30,"text":653,"correct":22},"幼儿园",{"key":121,"text":655,"correct":32},"总建筑面积大于100000m2的公共建筑",{"id":657,"libraryId":5,"type":15,"typeLabel":16,"stem":658,"options":659,"answer":20,"analysis":33},936892,"由单独的泡沫液泵按设定的压差向压力水流中注入泡沫液，并通过文丘里管（或孔板和文丘里管的结合），能在一定的水流压力或流量范围内自动控制混合比的比例混合装置是（ ）。",[660,662,664,666],{"key":20,"text":661,"correct":32},"平衡式比例混合器",{"key":24,"text":663,"correct":22},"压力式比例混合器",{"key":27,"text":665,"correct":22},"环泵式比例混合器",{"key":30,"text":667,"correct":22},"管线式比例混合器",[669,672,675,678,681,684],{"id":15,"name":670,"category":7,"favorite":671},"领导干部任职前廉政法规知识测试题",92,{"id":673,"name":674,"category":7,"favorite":15},595,"建筑结构与设备",{"id":676,"name":677,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":679,"name":680,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":682,"name":683,"category":7,"favorite":8},534,"BIM工程师",{"id":685,"name":683,"category":7,"favorite":8},535]