[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-43":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":672},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,43,50,2974,[13,34,46,58,70,82,100,115,130,142,154,166,178,193,205,219,231,246,258,270,282,294,309,324,336,348,362,374,389,404,418,432,447,459,471,483,495,510,522,536,548,562,574,586,601,613,625,637,648,660],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},936793,1,"单选题","下列（ ）建筑物不必设置室内消火栓给水系统。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","占地面积为2000m2的高层戊类厂房",false,{"key":24,"text":25,"correct":26},"B","建筑体积为9600m3且层高为3m的5层办公楼",true,{"key":28,"text":29,"correct":22},"C","建筑面积360m2的单层油浸变压器室",{"key":31,"text":32,"correct":22},"D","首层为商业网点的6层普通公寓","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},936794,"下列（ ）可以不设置疏散照明系统。",[38,40,42,44],{"key":20,"text":39,"correct":22},"消防电梯间前室",{"key":24,"text":41,"correct":22},"展览厅",{"key":28,"text":43,"correct":26},"层高4m的6层住宅楼",{"key":31,"text":45,"correct":22},"商场疏散走道",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},936795,"下列不可以作为消防水源的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"市政给水管网",{"key":24,"text":53,"correct":22},"地下消防水池",{"key":28,"text":55,"correct":22},"河流、池塘",{"key":31,"text":57,"correct":26},"高位消防水箱",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},936796,"下列不属于自带电源集中控制型系统的组成构件的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"应急照明控制器",{"key":24,"text":65,"correct":22},"应急照明配电箱",{"key":28,"text":67,"correct":22},"消防应急灯具",{"key":31,"text":69,"correct":26},"应急照明分配电装置",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},936797,"下列厂房或仓库中，按规范应设置排烟设施的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"每层建筑面积为1200m2的2层丙类仓库",{"key":24,"text":77,"correct":22},"丙类厂房内建筑面积为120m2的生产监控室",{"key":28,"text":79,"correct":22},"建筑面积为3000m2的丁类生产车间",{"key":31,"text":81,"correct":22},"单层丙类厂房内长度为35m的疏散走道",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":99,"analysis":33},936798,2,"多选题","下列场所的备用照明，应能保证正常照度的是（ ）。",[88,90,92,94,96],{"key":20,"text":89,"correct":26},"首层消防控制室",{"key":24,"text":91,"correct":22},"生活水泵房",{"key":28,"text":93,"correct":26},"通信机房",{"key":31,"text":95,"correct":26},"地下室发电机房",{"key":97,"text":98,"correct":26},"E","防排烟机房","ACDE",{"id":101,"libraryId":5,"type":84,"typeLabel":85,"stem":102,"options":103,"answer":114,"analysis":33},936799,"下列场所的消防用电应按二级负荷供电的有（ ）。",[104,106,108,110,112],{"key":20,"text":105,"correct":22},"建筑高度大于50m的乙、丙类生产厂房和丙类物品库房",{"key":24,"text":107,"correct":26},"座位数超过1500个的电影院、剧场",{"key":28,"text":109,"correct":22},"一类高层民用建筑",{"key":31,"text":111,"correct":26},"任一层建筑面积大于3000㎡的商店和展览建筑",{"key":97,"text":113,"correct":26},"省级广播电视大楼","BDE",{"id":116,"libraryId":5,"type":84,"typeLabel":85,"stem":117,"options":118,"answer":129,"analysis":33},936800,"下列场所宜选择点型感烟火灾探测器的是（ ）。",[119,121,123,125,127],{"key":20,"text":120,"correct":22},"厨房、锅炉房、发电机房、烘干车间",{"key":24,"text":122,"correct":26},"饭店、旅馆、教学楼、办公楼的厅堂、卧室、办公室、商场、列车载客车厢",{"key":28,"text":124,"correct":26},"楼梯、走道、电梯机房、车库",{"key":31,"text":126,"correct":26},"计算机房、通信机房、电影或电视放映室",{"key":97,"text":128,"correct":26},"书库、档案库","BCDE",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},936801,"下列场所中，消防用电应按一级负荷供电的是（ ）。、",[134,136,138,140],{"key":20,"text":135,"correct":22},"座位数超过3000个的体育馆",{"key":24,"text":137,"correct":22},"建筑高度为40m的丙类仓库",{"key":28,"text":139,"correct":22},"建筑高度为30m的乙类生产厂房",{"key":31,"text":141,"correct":26},"建筑高度为55m的住宅建筑",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},936802,"下列场所中，应在疏散走道和主要疏散路径的地面上增设能保持视觉连续的疏散指示标志的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"总建筑面积为6000m2的展览厅",{"key":24,"text":149,"correct":22},"座位数为1200个的剧场",{"key":28,"text":151,"correct":26},"总建筑面积为500m2的电子游艺厅",{"key":31,"text":153,"correct":22},"总建筑面积为500m2的地下超市",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":24,"analysis":33},936803,"下列对泵组式细水雾系统描述正确的（ ）。",[158,160,162,164],{"key":20,"text":159,"correct":22},"开式系统的泵组系统应设置稳压泵",{"key":24,"text":161,"correct":26},"系统管道宜采用专用接头或法兰接头，也可采用氩弧焊焊接",{"key":28,"text":163,"correct":22},"水泵采用柴油机泵时，应保证其能持续运行30min",{"key":31,"text":165,"correct":22},"在储水箱进水管口处应设置过滤器，出水口和控制阀后应设置过滤器",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":31,"analysis":33},936804,"下列对供水设施的维护管理中，说法正确的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":22},"每日应手动启动消防水泵运转一次，并应检查供电电源的情况",{"key":24,"text":173,"correct":22},"每年对气压水罐的压力和有效容积进行检测一次",{"key":28,"text":175,"correct":22},"每周应模拟消防水泵自动控制的条件自动启动消防水泵运转一次，且应自动记录自动巡检情况，每周应检测记录",{"key":31,"text":177,"correct":26},"每季度应对消防水泵的出流量和压力进行一次试验",{"id":179,"libraryId":5,"type":84,"typeLabel":85,"stem":180,"options":181,"answer":192,"analysis":33},936805,"下列对泡沫灭火系统泡沫液的选择和储存说法，正确的是（ ）。",[182,184,186,188,190],{"key":20,"text":183,"correct":26},"当采用液上喷射系统时，应选用蛋白、氟蛋白、成膜氟蛋白或水成膜泡沫液",{"key":24,"text":185,"correct":26},"当采用液下喷射系统时，应选用氟蛋白、成膜氟蛋白或水成膜泡沫液",{"key":28,"text":187,"correct":26},"用一套系统同时保护水溶性和非水溶性甲、乙、丙类液体的，必须选用抗溶泡沫液",{"key":31,"text":189,"correct":22},"用于油罐的中倍数泡沫灭火剂应采用专用6%型氟蛋白泡沫液",{"key":97,"text":191,"correct":26},"高倍数泡沫灭火系统利用热烟气发泡时，应采用耐温耐烟型高倍数泡沫液","ABCE",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":24,"analysis":33},936806,"下列对泡沫灭火系统中泡沫混合液的表述正确的是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"可按适宜的混合比与水混合形成泡沫溶液的浓缩液体",{"key":24,"text":200,"correct":26},"泡沫液与水按特定混合比配制成的泡沫溶液",{"key":28,"text":202,"correct":22},"泡沫液与水按特定混合比预先配制成的储存待用的泡沫溶液",{"key":31,"text":204,"correct":22},"泡沫灭火系统中泡沫液泵为系统所提供的溶液",{"id":206,"libraryId":5,"type":84,"typeLabel":85,"stem":207,"options":208,"answer":192,"analysis":33},936807,"下列对细水雾系统分区控制阀的描述正确的（ ）。",[209,211,213,215,217],{"key":20,"text":210,"correct":26},"开式系统应按防护区设置分区控制阀，每个分区控制阀上或阀后邻近位置宜设置泄放试验阀",{"key":24,"text":212,"correct":26},"闭式系统应按楼层或者防火分区设置分区控制阀，分区控制阀应为带开关锁定或开关指示的阀组",{"key":28,"text":214,"correct":26},"分区控制阀上宜设置系统动作信号反馈装置，当分区控制阀上无系统动作反馈装置时，应在分区控制阀后的配水干管上设置系统动作信号反馈装置",{"key":31,"text":216,"correct":22},"开式和闭式系统的每个分区控制阀后的管网应设置试水阀",{"key":97,"text":218,"correct":26},"开式系统分区控制阀应能在接到动作指令后立即启动并发出动作信号。闭式系统当分区控制阀采用信号阀时，应能反馈阀门的启闭状态和故障信号",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":31,"analysis":33},936808,"下列对细水雾系统设置及控制描述正确的（ ）。",[223,225,227,229],{"key":20,"text":224,"correct":22},"瓶组式系统应具有自动、手动两种控制方式",{"key":24,"text":226,"correct":22},"瓶组式系统，系统的设计持续喷雾时间可按其实体火灾模拟试验灭火时间的2倍确定，且不宜小于20min",{"key":28,"text":228,"correct":22},"系统宜选用泵组系统，闭式系统不宜采用瓶组系统",{"key":31,"text":230,"correct":26},"瓶组式系统的供水装置的储水容器及储气容器均应设置安全阀",{"id":232,"libraryId":5,"type":84,"typeLabel":85,"stem":233,"options":234,"answer":245,"analysis":33},936809,"下列符合火灾自动报警系统控制器类设备在消防控制室内布置要求的有（ ）。",[235,237,239,241,243],{"key":20,"text":236,"correct":26},"设备面盘后的维修距离不宜小于1m",{"key":24,"text":238,"correct":26},"设备面盘的排列长度大于4m时，其两端应设置宽度不小于1m的通道",{"key":28,"text":240,"correct":22},"在值班人员经常工作的一面，设备面盘至墙的距离不应小于4m",{"key":31,"text":242,"correct":22},"设备面盘前的操作距离，单列布置时不应小于1m，双列布置时不应小于2m",{"key":97,"text":244,"correct":26},"与建筑内其他弱电系统合用的消防控制室内，消防设备应集中设置，并应与其他设备间有明显间隔","ABE",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":28,"analysis":33},936810,"下列关于“用作两路消防供水的市政给水管网”的要求叙述不正确的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"水厂应连续的向市政给水管网输水",{"key":24,"text":253,"correct":22},"市政给水管网应为环状管网",{"key":28,"text":255,"correct":26},"应不同主干道路上接不少于两条引入管向消防给水系统供水",{"key":31,"text":257,"correct":22},"应从环状管网的不同主干管上接不少于两条引入管向消防给水系统供水",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":24,"analysis":33},936811,"下列关于柴油机消防泵的说法中不正确的是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"柴油机消防水泵应采用压缩式点火型柴油机",{"key":24,"text":265,"correct":26},"柴油机消防水泵应具备连续工作的性能，试验运行时间不应小于12h",{"key":28,"text":267,"correct":22},"柴油机消防水泵的蓄电池应保证消防水泵随时自动启泵的要求",{"key":31,"text":269,"correct":22},"柴油机消防水泵油箱内储存的燃料不应小于50%的储量",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":31,"analysis":33},936812,"下列关于储罐区和工艺装置区室外消火栓的说法中，错误的是（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"可燃液体储罐区的室外消火栓，应设置在防火堤外，距离罐壁15m范围内的消火栓不应计入该罐可使用的消火栓数量",{"key":24,"text":277,"correct":22},"采用临时高压消防给水系统的工艺装置区，室外消火栓的间距不应大于60m",{"key":28,"text":279,"correct":22},"采用高压消防给水系统且宽带大于120m的工艺装置区，宜在该工艺装置区内的路边设置室外消火栓",{"key":31,"text":281,"correct":26},"液化烃储罐区的室外消火栓，应设置在防护墙外，距离罐壁15m范围内的消火栓可计入该罐可使用的消火栓数量",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":28,"analysis":33},936813,"下列关于干式自动喷水灭火系统的说法中，错误的是（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"在准工作状态下，由稳压系统维持干式报警阀入口前管道内的充水压力",{"key":24,"text":289,"correct":22},"在准工作状态下，干式报警阀出口后的配水管道内应充满有压气体",{"key":28,"text":291,"correct":26},"当发生火灾后，干式报警阀开启，压力开关动作后管网开始排气充水",{"key":31,"text":293,"correct":22},"当发生火灾后，配水管道排气充水后，开启的喷头开始喷水",{"id":295,"libraryId":5,"type":84,"typeLabel":85,"stem":296,"options":297,"answer":308,"analysis":33},936814,"下列关于火灾报警类产品维修保养的叙述，不正确的是（ ）。",[298,300,302,304,306],{"key":20,"text":299,"correct":26},"不同类型的探测器应有10%且不少于20只的备品",{"key":24,"text":301,"correct":26},"一般火灾探测器的使用寿命为10年，每3年要求全面清洗一次",{"key":28,"text":303,"correct":26},"可燃气体探测器的气敏元件使用满2年后应及时更换",{"key":31,"text":305,"correct":22},"具有报脏功能的探测器，应在报脏时及时清洗保养",{"key":97,"text":307,"correct":22},"没有报脏功能的探测器，当说明书没有明确要求的，应每2年清洗或标定一次","ABC",{"id":310,"libraryId":5,"type":84,"typeLabel":85,"stem":311,"options":312,"answer":323,"analysis":33},936815,"下列关于火灾声光警报器的做法中，正确的有（ ）。",[313,315,317,319,321],{"key":20,"text":314,"correct":26},"火灾自动报警系统能同时启动和停止所有火灾声光警报器工作",{"key":24,"text":316,"correct":22},"火灾声光警报器必须只能采用火灾报警控制器控制",{"key":28,"text":318,"correct":22},"火灾声警报与消防应急广播同步播放",{"key":31,"text":320,"correct":26},"学校阅览室，礼堂等公共场所采用具有同一种火灾变调声的火灾声警报器",{"key":97,"text":322,"correct":22},"教学楼使用警铃作为火灾声警报器","AD",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":24,"analysis":33},936816,"下列关于火灾自动报警系统的检测操作的说法中不正确的是（ ）。",[328,330,332,334],{"key":20,"text":329,"correct":22},"各类消防用电设备主用、备用电源的电动转换装置，应进行3次转换试验",{"key":24,"text":331,"correct":26},"火灾报警控制器及消防联动控制系统中所有组件应全部进行功能检验",{"key":28,"text":333,"correct":22},"室内消火栓、自喷系统应在消防控制室内操作启、停泵1-3次",{"key":31,"text":335,"correct":22},"气体、泡沫、干粉等灭火系统应自动、手动启动和紧急切断试验1-3次",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":24,"analysis":33},936817,"下列关于火灾自动报警系统组件设置的做法中，错误的是（ ）。",[340,342,344,346],{"key":20,"text":341,"correct":22},"壁挂手动火灾报警按钮的底边距离楼地面1.4m",{"key":24,"text":343,"correct":26},"壁挂紧急广播扬声器的底边距离楼地面2.0m",{"key":28,"text":345,"correct":22},"壁挂消防联动控制器的主显示屏的底边距离楼地面1.5m",{"key":31,"text":347,"correct":22},"墙上安装的消防专用电话插孔的底边距离楼地面1.3m",{"id":349,"libraryId":5,"type":84,"typeLabel":85,"stem":350,"options":351,"answer":114,"analysis":33},936818,"下列关于机械加压送风系统的说法正确的是（ ）。",[352,354,356,358,360],{"key":20,"text":353,"correct":22},"防烟楼梯间宜每隔4-5层设置一个加压送风口",{"key":24,"text":355,"correct":26},"前室或合用前室只能选用常闭式加压送风口",{"key":28,"text":357,"correct":22},"闭式加压送风口设手动或电动可开启装置，且手动开启装置的高度距地面1.3-1.5m",{"key":31,"text":359,"correct":26},"机械加压送风机与排烟风机设置在同一平面时，其水平距离不应小于1Om",{"key":97,"text":361,"correct":26},"封闭的避难层应设独立的机械加压送风系统",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":28,"analysis":33},936819,"下列关于建筑防烟系统联动控制要求的做法中，错误的是（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":22},"常闭加压送风口开启由其所在防火分区内两只独立火灾探测器的报警信号作为联动触发信号",{"key":24,"text":369,"correct":22},"加压送风机启动由其所在防火分区内的一只火灾探测器与一只手动火灾报警按钮的报警信号作为联动触发信号",{"key":28,"text":371,"correct":26},"楼梯间的前室或合用前室的加压送风系统中任一常闭加压送风口开启时，联动启动该楼梯间各楼层的前室及合用前室内的常闭加压送风口",{"key":31,"text":373,"correct":22},"对于防火分区跨越多个楼层的建筑，楼梯间的前室或合用前室内任一常闭加压送风口开启时联动启动该防火分区内全部楼层的楼梯间前室及合用前室内的常闭加压送风口",{"id":375,"libraryId":5,"type":84,"typeLabel":85,"stem":376,"options":377,"answer":388,"analysis":33},936820,"下列关于建筑室外消火栓的设置要求的说法中错误的是（ ）。",[378,380,382,384,386],{"key":20,"text":379,"correct":26},"建筑室外消火栓的数量应根据室外消火栓设计流量和保护半径经计算确定，保护半径不应大于120m，每个室外消火栓的出流量宜按10L\u002FS~15L\u002FS计算",{"key":24,"text":381,"correct":22},"室外消火栓宜沿建筑周围均匀布置，且不宜集中布置在建筑一侧，建筑消防扑救面一侧的室外消火栓数量不宜少于2个",{"key":28,"text":383,"correct":22},"人防工程、地下工程等建筑应在出入口附近设置室外消火栓，且距出入口的距离不宜小于5m，并不宜大于40m",{"key":31,"text":385,"correct":26},"停车场的室外消火栓宜沿停车场周围设置，且与最近一排汽车的距离不宜小于8m，距加油站或油库不宜小于15m",{"key":97,"text":387,"correct":26},"甲乙丙类液体储罐区和液化烃罐区等构筑物的室外消火栓，经设在防火堤或防护墙外，数量应根据每个罐的设计流量经计算确定，但距罐壁15m范围内的消火栓，应计算在该罐可使用的数量内。","ADE",{"id":390,"libraryId":5,"type":84,"typeLabel":85,"stem":391,"options":392,"answer":403,"analysis":33},936821,"下列关于建筑需要设置排烟系统的说法正确的是（ ）。",[393,395,397,399,401],{"key":20,"text":394,"correct":26},"设置在一、二、三层且房间建筑面积大于1OOm2的歌舞娱乐放映游艺场所，设置在四层及以上楼层、地下或半地下室的歌舞娱乐放映游艺场所",{"key":24,"text":396,"correct":26},"中庭",{"key":28,"text":398,"correct":26},"人员、可燃物较多的丙类生产场所",{"key":31,"text":400,"correct":26},"丙类厂房中建筑面积大于300m2且经常有人停留或可燃物较多的地上房间",{"key":97,"text":402,"correct":22},"建筑面积大于300m2的丁类生产车间","ABCD",{"id":405,"libraryId":5,"type":84,"typeLabel":85,"stem":406,"options":407,"answer":308,"analysis":33},936822,"下列关于埋地消防给水管道防腐的说法中，正确的是（ ）。",[408,410,412,414,416],{"key":20,"text":409,"correct":26},"埋地钢管应做防腐处理",{"key":24,"text":411,"correct":26},"室外埋地球墨铸铁给水管要求外壁应刷沥青漆防腐",{"key":28,"text":413,"correct":26},"埋地管道连接用的螺栓、螺母以及垫片等附件应采用防腐蚀材料，或涂覆沥青涂层等防腐涂层",{"key":31,"text":415,"correct":22},"埋地钢丝网骨架塑料复合管应做防腐处理",{"key":97,"text":417,"correct":22},"埋地钢管的防腐应按现行国家标准《消防给水及消火栓系统设计规范》的有关规定施工",{"id":419,"libraryId":5,"type":84,"typeLabel":85,"stem":420,"options":421,"answer":192,"analysis":33},936823,"下列关于灭火器的配置要求描述中正确的是（ ）。",[422,424,426,428,430],{"key":20,"text":423,"correct":26},"当一个楼层或一个水平防火分区内各场所的危险等级和火灾种类相同时，可将其作为一个计算单元",{"key":24,"text":425,"correct":26},"当一个楼层或一个水平防火分区内各场所的危险等级和火灾种类不相同时，应将其分别作为不同的计算单元",{"key":28,"text":427,"correct":26},"同一计算单元不得跨越防火分区和楼层",{"key":31,"text":429,"correct":22},"建筑物应按其建筑使用面积确定计算单元保护面积",{"key":97,"text":431,"correct":26},"可燃物露天堆场，甲、乙、丙类液体储罐区，可燃气体储罐区应按堆垛、储罐的占地面积确定计算单元保护面积",{"id":433,"libraryId":5,"type":84,"typeLabel":85,"stem":434,"options":435,"answer":446,"analysis":33},936824,"下列关于民用建筑需要设置排烟系统的说法正确的是那几项（ ）。",[436,438,440,442,444],{"key":20,"text":437,"correct":22},"公共建筑内建筑面积大于1OOm2且可燃物较多的地上房间",{"key":24,"text":439,"correct":26},"设置在四层且房间建筑面积为1OOm2的歌舞娱乐放映游艺场所",{"key":28,"text":441,"correct":26},"建筑内长度大于20m的疏散走道",{"key":31,"text":443,"correct":22},"总建筑面积为200m2地上建筑内的无窗房间，且经常有人停留",{"key":97,"text":445,"correct":26},"设置在地下室的歌舞娱乐放映游艺场所","BCE",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":31,"analysis":33},936825,"下列关于喷头布置的叙述中，（ ）是错误的。",[451,453,455,457],{"key":20,"text":452,"correct":22},"净空高度为900mm的闷顶和技术夹层内有可燃物，应设置喷头",{"key":24,"text":454,"correct":22},"净空高度为900mm的技术夹层内部无可燃物且吊顶及项板为不燃材料制作，可不设置喷头",{"key":28,"text":456,"correct":22},"装设通透性吊顶的场所，喷头应布置在顶板下",{"key":31,"text":458,"correct":26},"装设通透性吊顶的场所，采用吊顶喷头时喷头可布置在吊顶下",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":31,"analysis":33},936826,"下列关于喷头动作流程的叙述中，（ ）是错误的。",[463,465,467,469],{"key":20,"text":464,"correct":22},"湿式系统：喷头动作一湿式报警阀动作",{"key":24,"text":466,"correct":22},"干式系统：喷头动作_加速排气_干式报警阀动作",{"key":28,"text":468,"correct":22},"预作用系统：探测器动作_雨淋阀动作",{"key":31,"text":470,"correct":26},"水幕系统：水幕喷头动作一雨淋阀动作",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":31,"analysis":33},936827,"下列关于喷头选型的叙述中，（ ）是错误的。",[475,477,479,481],{"key":20,"text":476,"correct":22},"吊顶型喷头分为平齐型、半隐蔽型和隐蔽型三种型式",{"key":24,"text":478,"correct":22},"干式系统可采用特殊的下垂型喷头",{"key":28,"text":480,"correct":22},"水幕喷头可采用开式洒水喷头",{"key":31,"text":482,"correct":26},"建筑高度为50m的5星级酒店的房间宜采用快速响应喷头",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":24,"analysis":33},936828,"下列关于气体灭火的叙述中，（ ）是错误的。",[487,489,491,493],{"key":20,"text":488,"correct":22},"对一些大防护区、大设计用量的系统来说，采用两套或三套管网设计是有优势的",{"key":24,"text":490,"correct":26},"同一防护区，当设计两套管网时，集流管、启动瓶可分别设置",{"key":28,"text":492,"correct":22},"管网上不应采用四通管件进行分流",{"key":31,"text":494,"correct":22},"管网可以采用三通管件进行分流",{"id":496,"libraryId":5,"type":84,"typeLabel":85,"stem":497,"options":498,"answer":509,"analysis":33},936829,"下列关于气体灭火的叙述中，错误的有（ ）。",[499,501,503,505,507],{"key":20,"text":500,"correct":22},"采用自动控制启动方式时，根据人员安全撤离防护区的需要，应有不大于30s的可控延迟喷射",{"key":24,"text":502,"correct":26},"对于平时无人工作的防护区，应有不大于1Os的可控延迟喷射",{"key":28,"text":504,"correct":22},"自动控制装置应在接到两个独立的火灾信号后才能启动",{"key":31,"text":506,"correct":26},"手动控制装置和手动与自动转换装置应设在防护区疏散出口的门外便于操作的地方，安装高度为中心点距地面1.2m",{"key":97,"text":508,"correct":22},"机械应急操作装置应设在储瓶间内或防护区疏散出口门外便于操作的地方","BD",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":28,"analysis":33},936830,"下列关于气体灭火设计喷放时间和灭火浸渍时间，下列叙述中错误的是。",[514,516,518,520],{"key":20,"text":515,"correct":22},"七氟丙烷设计喷放时间要求比IG541短",{"key":24,"text":517,"correct":22},"IG541的设计喷放时间不是越快越好",{"key":28,"text":519,"correct":26},"浸渍时间主要针对深位火灾",{"key":31,"text":521,"correct":22},"IG541用于通讯机房的电气设备火灾时，渍时间宜采用10min",{"id":523,"libraryId":5,"type":84,"typeLabel":85,"stem":524,"options":525,"answer":114,"analysis":33},936831,"下列关于气体灭火系统操作和控制的说法中，正确的有（ ）。",[526,528,530,532,534],{"key":20,"text":527,"correct":22},"组合分配系统启动时，选择阀应在容器阀开启后打开",{"key":24,"text":529,"correct":26},"采用气体灭火系统防护区应选用灵敏度级别高的火灾探测器",{"key":28,"text":531,"correct":22},"自动控制装置应在接到任一火灾信号后联动启动",{"key":31,"text":533,"correct":26},"预制灭火系统应设置自动控制和手动控制两种启动方式",{"key":97,"text":535,"correct":26},"气体灭火系统的操作和控制应包括对防火阀、通风机械、开口封闭装置的联动操作与控制",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":24,"analysis":33},936832,"下列关于气体灭火系统联动控制设计的说法中错误的（ ）",[540,542,544,546],{"key":20,"text":541,"correct":22},"气体灭火系统应由专用的气体灭火控制器控制",{"key":24,"text":543,"correct":26},"相邻防护区域内两只独立的火灾探测器的报警信号可以作为系统的联动触发信号",{"key":28,"text":545,"correct":22},"防护区疏散出口的门外应设置气体灭火装置的手动启动和停止按钮",{"key":31,"text":547,"correct":22},"气体灭火装置启动及喷放各阶段的联动控制及系统的反馈信号，应反馈至消防联动控制器",{"id":549,"libraryId":5,"type":84,"typeLabel":85,"stem":550,"options":551,"answer":99,"analysis":33},936833,"下列关于气体灭火系统设计的叙述中，正确的是（ ）。",[552,554,556,558,560],{"key":20,"text":553,"correct":26},"同一集流管上的储存容器，其规格、冲压压力和充装量应相同",{"key":24,"text":555,"correct":22},"储存装置的储存容器与其它组件的公称工作压力，不应大于在最高环境温度下所承受的工作压力",{"key":28,"text":557,"correct":26},"在储存容器或容器阀上，应设安全泄压装置和压力表",{"key":31,"text":559,"correct":26},"组合分配系统的集流管，应设安全泄压装置",{"key":97,"text":561,"correct":26},"安全泄压装置的动作压力，应符合相应气体灭火系统的设计规定",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":20,"analysis":33},936834,"下列关于室内消防水箱及增压设施的叙述中，（ ）是正确的。",[566,568,570,572],{"key":20,"text":567,"correct":26},"设置常高压给水系统的超高层民用建筑，高位水池一般不能满足上部楼层灭火所需的流量和压力，需要设置高位消防水箱及消防泵给上部楼层供水灭火",{"key":24,"text":569,"correct":22},"民用建筑应设置高位消防水箱，但当设置高位消防水箱确有困难，且采用安全可靠的消防给水形式时，可不设高位消防水箱，也不设稳压泵",{"key":28,"text":571,"correct":22},"建筑高度大于100m的住宅建筑，总建筑面积大于30000m2的商店，高位消防水箱的有效容积不应小于50m3",{"key":31,"text":573,"correct":22},"高位消防水箱可分区设置，减压水箱可作为高位消防水箱",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":31,"analysis":33},936835,"下列关于室内消火栓给水系统的叙述中，（ ）是错误的。",[578,580,582,584],{"key":20,"text":579,"correct":22},"室内消火栓给水应与自动喷水灭火系统分开设置，特殊情况下可合用消防泵",{"key":24,"text":581,"correct":22},"高层民用建筑的室内消防给水系统，应与生活给水系统分开独立设置",{"key":28,"text":583,"correct":22},"室内消防给水管道、消防水池与室外生活给水管或生活一消防合用管道连接时，应采取防止回流污染的技术措施",{"key":31,"text":585,"correct":26},"高层厂房室内消防给水系统在满足条件时可与生产给水系统合用",{"id":587,"libraryId":5,"type":84,"typeLabel":85,"stem":588,"options":589,"answer":600,"analysis":33},936836,"下列关于室外临时高压给水系统的叙述中，（ ）是错误的。",[590,592,594,596,598],{"key":20,"text":591,"correct":22},"工艺装置区、储罐区等场所应采用高压或临时高压消防给水系统",{"key":24,"text":593,"correct":22},"当室外采用高压或临时高压消防给水系统时，宜与室内消防给水系统合用",{"key":28,"text":595,"correct":26},"独立的室外临时高压消防给水系统应与市政管网连接，保证平时室外消火栓的水压",{"key":31,"text":597,"correct":26},"严寒、寒冷地区的市政消火栓和建筑室外消火栓系统宜采用干式消火栓系统",{"key":97,"text":599,"correct":22},"独立的室外临时高压消防给水系统宜采用稳压泵维持系统的充水和压力","CD",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":24,"analysis":33},936837,"下列关于室外消火栓布置的叙述中正确的是哪一个（ ）。",[605,607,609,611],{"key":20,"text":606,"correct":22},"向生活小区环状管网输水的进水管不应少于2条，当其中一条发生故障，其余的进水管应能保证70%的消防用水量",{"key":24,"text":608,"correct":26},"室外消防给水管道的直径不应小于DN100",{"key":28,"text":610,"correct":22},"当道路宽度大于50m时，应在道路两边设置消火栓，并宜靠近十字路口",{"key":31,"text":612,"correct":22},"与保护对象的距离在160m范围内的市政消火栓，可计入室外消火栓的数量内",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":31,"analysis":33},936838,"下列关于室外消火栓设置场所的叙述中，（ ）是错误的。",[617,619,621,623],{"key":20,"text":618,"correct":22},"城镇（包括居住区、商业区、开发区、工业区等）应沿可通行消防车的街道设置市政消火栓系统",{"key":24,"text":620,"correct":22},"民用建筑、厂房、仓库、储罐（区）和堆场周围应设置室外消火栓系统",{"key":28,"text":622,"correct":22},"用于消防救援和消防车停靠的屋面上，应设置室外消火栓系统",{"key":31,"text":624,"correct":26},"居住人数不超过5000人且建筑层数不超过10层的住宅建筑，可不设置室外消火栓系统",{"id":626,"libraryId":5,"type":15,"typeLabel":16,"stem":627,"options":628,"answer":20,"analysis":33},936839,"下列关于室外消火栓设置的说法中，错误的是（ ）。",[629,631,633,635],{"key":20,"text":630,"correct":26},"室外消火栓应集中布置在建筑消防扑救面一侧，且不宜小于2个",{"key":24,"text":632,"correct":22},"室外消火栓的保护半径不应大于150m",{"key":28,"text":634,"correct":22},"地下民用建筑应在出入口附近设置室外消火栓，且距离出入口不宜小于5m、不宜大于40m",{"key":31,"text":636,"correct":22},"停车场的室外消火栓与最近一排汽车的距离不宜小于7m",{"id":638,"libraryId":5,"type":84,"typeLabel":85,"stem":639,"options":640,"answer":403,"analysis":33},936840,"下列关于室外消火栓系统设置正确的是（ ）。",[641,643,644,645,646],{"key":20,"text":642,"correct":26},"市政消火栓和建筑室外消火栓应采用湿式消火栓系统",{"key":24,"text":618,"correct":26},{"key":28,"text":620,"correct":26},{"key":31,"text":622,"correct":26},{"key":97,"text":647,"correct":22},"汽车库、修车库、停车场应设置室外消火栓系统",{"id":649,"libraryId":5,"type":15,"typeLabel":16,"stem":650,"options":651,"answer":24,"analysis":33},936841,"下列关于水流指示器描述中不正确的是（ ）。",[652,654,656,658],{"key":20,"text":653,"correct":22},"水流指示器的作用是将水流信号转换成电信号，及时报告发生火灾的部位",{"key":24,"text":655,"correct":26},"每个防火分区和每个楼层均应设水流指示器",{"key":28,"text":657,"correct":22},"仓库内顶板下喷头与货架内喷头应分别设置",{"key":31,"text":659,"correct":22},"当水流指示器入口前设置控制阀时，应采用信号阀",{"id":661,"libraryId":5,"type":15,"typeLabel":16,"stem":662,"options":663,"answer":20,"analysis":33},936842,"下列关于水喷雾灭火系统的叙述中，错误的是（ ）。",[664,666,668,670],{"key":20,"text":665,"correct":26},"《水喷雾灭火系统技术规范》适用于运输工具水喷雾灭火系统的设计",{"key":24,"text":667,"correct":22},"水喷雾灭火系统可用于扑救固体火灾，闪点高于60℃的液体火灾和电气火灾",{"key":28,"text":669,"correct":22},"水喷雾灭火系统不得用于扑救遇水发生化学反应造成燃烧、爆炸的火灾",{"key":31,"text":671,"correct":22},"可燃油油浸电力变压器宜设水喷雾灭火系统",[673,676,679,682,685,688],{"id":15,"name":674,"category":7,"favorite":675},"领导干部任职前廉政法规知识测试题",92,{"id":677,"name":678,"category":7,"favorite":15},595,"建筑结构与设备",{"id":680,"name":681,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":683,"name":684,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":686,"name":687,"category":7,"favorite":8},534,"BIM工程师",{"id":689,"name":687,"category":7,"favorite":8},535]