[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-605-42":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":622},{"id":5,"name":6,"category":7,"favorite":8},605,"消防技术综合能力(一级、二级)","建筑工程",0,42,50,2974,[13,34,46,58,70,78,90,102,114,126,137,149,161,173,182,194,206,218,230,240,252,264,282,297,306,315,327,336,348,360,372,384,396,405,416,428,443,458,469,481,493,507,522,530,545,557,572,583,595,610],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},936743,1,"单选题","某博物馆珍宝库长×宽×高=30mx25mx6m，拟设置七氟丙烷气体灭火系统，下列系统设置中，（ ）正确合理。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","采用管网灭火系统，设一个防护区",false,{"key":24,"text":25,"correct":26},"B","采用管网灭火系统，设两个防护区",true,{"key":28,"text":29,"correct":22},"C","采用预制灭火系统，设两个防护区，每区设一台预制气体灭火系统装置",{"key":31,"text":32,"correct":22},"D","采用预制灭火系统，设两个防护区，每区设两台预制气体灭火系统装置","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},936744,"某储罐区有4个固定项轻柴油储罐，单罐容积为2000m3，设置了低倍数泡沫灭火系统，该泡沫灭火系统的设计保护面积应按（ ）确定。",[38,40,42,44],{"key":20,"text":39,"correct":22},"储罐罐壁与泡沫堰板间的环形面积",{"key":24,"text":41,"correct":22},"储罐表面积",{"key":28,"text":43,"correct":26},"储罐横截面面积",{"key":31,"text":45,"correct":22},"防火堤内的地面面积",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},936745,"某纺织厂人造棉仓库由于纤维织物堆积时有阴燃发生，该场所应选用的火灾探测器是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"感温火灾探测器",{"key":24,"text":53,"correct":26},"感烟火灾探测器",{"key":28,"text":55,"correct":22},"火焰探测器",{"key":31,"text":57,"correct":22},"气体火灾探测器",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},936746,"某高层宾馆，下列关于消防设备配电装置的做法中，不能满足消防设备供电要求的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"引至消防泵的两路电源在泵房内末端自动切换",{"key":24,"text":65,"correct":22},"消防负荷的配电线路设置短路动作保护装置",{"key":28,"text":67,"correct":26},"消防负荷的配电线路设置过负荷和过、欠电压保护装置",{"key":31,"text":69,"correct":22},"消防负荷的配电线路未设置剩余电流保护装置",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},936747,"某工厂储罐区有单罐容积为5000m3凝析油内浮顶储罐，储罐均采用铝合金制作浮盘的内浮顶储罐，则该泡沫灭火系统的设计保护面积应按（ ）确定。",[74,75,76,77],{"key":20,"text":39,"correct":22},{"key":24,"text":41,"correct":22},{"key":28,"text":43,"correct":26},{"key":31,"text":45,"correct":22},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":28,"analysis":33},936748,"某工业厂区采用厂区用地界线内一河流作为消防水源，则对消防水源检查中下列说法错误的是（ ）。",[82,84,86,88],{"key":20,"text":83,"correct":22},"取水口设置格栅或过滤等措施来保证取水的可靠性",{"key":24,"text":85,"correct":22},"消防车在取水时，最大吸水高度不应超过6.0m",{"key":28,"text":87,"correct":26},"当井水作为消防水源时，可以不设置探测河水水位的水位测试装置",{"key":31,"text":89,"correct":22},"应设置消防车到这取水口的消防车道和消防车回车场或回车道",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":24,"analysis":33},936749,"某火力发电厂输煤栈桥输送皮带总长405m，采用水喷雾灭火系统保护时，该输煤栈桥最多可划分为（ ）段分段进行保护。",[94,96,98,100],{"key":20,"text":95,"correct":22},"5",{"key":24,"text":97,"correct":26},"4",{"key":28,"text":99,"correct":22},"6",{"key":31,"text":101,"correct":22},"7",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":31,"analysis":33},936750,"某建筑采用临时高压给水系统，消防水泵的工作压力为1.0MPa，选择消防泵时，消防泵零流量时的压力为（ ）。",[106,108,110,112],{"key":20,"text":107,"correct":22},"0.9～1.2MPa",{"key":24,"text":109,"correct":22},"1.1～1.3MPa",{"key":28,"text":111,"correct":22},"0.9～1.3MPa",{"key":31,"text":113,"correct":26},"1.2～1.4MPa",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":20,"analysis":33},936751,"某建筑高度为105米的民用建筑，其消防应急照明备用电源的连续供电时间不应低于（ ）min。",[118,120,122,124],{"key":20,"text":119,"correct":26},"90",{"key":24,"text":121,"correct":22},"60",{"key":28,"text":123,"correct":22},"30",{"key":31,"text":125,"correct":22},"15",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":31,"analysis":33},936752,"某建筑内的火灾自动报警系统中安装有相同型号的感烟火灾探测器1460只，按照相关规范的要求，该建筑的消防维护管理单位应至少储备（ ）只相同型号的感烟火灾探测器。",[130,131,133,135],{"key":20,"text":125,"correct":22},{"key":24,"text":132,"correct":22},"50",{"key":28,"text":134,"correct":22},"73",{"key":31,"text":136,"correct":26},"146",{"id":138,"libraryId":5,"type":15,"typeLabel":16,"stem":139,"options":140,"answer":20,"analysis":33},936753,"某建筑内走道宽度2.0米，在内走道顶棚上居中安装安装探测器时，点型感温探测器的安装间距不应超过（ ）米，点型感烟探测器的安装间距不应超过（ ）米。探测器距墙的距离不应大于安装距离的一半。",[141,143,145,147],{"key":20,"text":142,"correct":26},"10，15",{"key":24,"text":144,"correct":22},"15，10",{"key":28,"text":146,"correct":22},"15，20",{"key":31,"text":148,"correct":22},"20，15",{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":31,"analysis":33},936754,"某建筑设置的七氟丙烷管网灭火系统，其储存容器的增压压力为4.2MPa，下列关于该系统的设计，（ ）不正确。",[153,155,157,159],{"key":20,"text":154,"correct":22},"储存容器采用焊接容器",{"key":24,"text":156,"correct":22},"该系统的设计喷放时间为8s",{"key":28,"text":158,"correct":22},"该系统共设置8个选择阀防护9个房间",{"key":31,"text":160,"correct":26},"管网计算结果：喷头处的工作压力为0.6MPa（绝对压力）",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":33},936755,"某净空高度为8m的自选商场，设有集中采暖空调系统，选择（ ）自动喷水灭火系统类型为正确合理。",[165,167,169,171],{"key":20,"text":166,"correct":22},"预作用系统",{"key":24,"text":168,"correct":26},"湿式系统",{"key":28,"text":170,"correct":22},"雨淋系统",{"key":31,"text":172,"correct":22},"干式系统",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":24,"analysis":33},936756,"某可燃物堆场，室外消火栓的设计流量为55L\u002Fs，室外消火栓选用DN150，其出水流量为15L\u002Fs。根据室外消火栓设计流量，该堆场的室外消火栓数量不应少于（ ）个。",[177,178,179,180],{"key":20,"text":99,"correct":22},{"key":24,"text":97,"correct":26},{"key":28,"text":95,"correct":22},{"key":31,"text":181,"correct":22},"3",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":24,"analysis":33},936757,"某库房设有室内消火栓给水系统，则其消火栓水枪的充实水柱长度不应小于（ ）。",[186,188,190,192],{"key":20,"text":187,"correct":22},"7m",{"key":24,"text":189,"correct":26},"13m",{"key":28,"text":191,"correct":22},"10m",{"key":31,"text":193,"correct":22},"8m",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":24,"analysis":33},936758,"某商业中庭设置防火卷帘分隔，其上设置防护冷却水幕系统，喷水点高度为12米，则水幕系统喷水强度应为下列（ ）。",[198,200,202,204],{"key":20,"text":199,"correct":22},"0.5L\u002Fs·m",{"key":24,"text":201,"correct":26},"1L\u002Fs·m",{"key":28,"text":203,"correct":22},"1.3L\u002Fs·m",{"key":31,"text":205,"correct":22},"2L\u002Fs·m",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":31,"analysis":33},936759,"某省一座大型图书馆内设有贵重图书珍藏库，该库设置下列哪种消防系统。",[210,212,214,216],{"key":20,"text":211,"correct":22},"自动喷水灭火系统",{"key":24,"text":213,"correct":22},"水喷雾灭火系统",{"key":28,"text":215,"correct":22},"泡沫灭火系统",{"key":31,"text":217,"correct":26},"气体灭火系统",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":24,"analysis":33},936760,"某数据处理控制中心设有七氟丙烷气体灭火系统，系统启动灭火时，防护区实际使用浓度不应大于下列（ ）。",[222,224,226,228],{"key":20,"text":223,"correct":22},"灭火设计浓度",{"key":24,"text":225,"correct":26},"有毒性反应浓度",{"key":28,"text":227,"correct":22},"惰化设计浓度",{"key":31,"text":229,"correct":22},"无毒性反应浓度",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":24,"analysis":33},936761,"某通信机房设置七氟丙烷预制灭火系统，该系统应有（ ）种启动方式。",[234,236,238,239],{"key":20,"text":235,"correct":22},"1",{"key":24,"text":237,"correct":26},"2",{"key":28,"text":181,"correct":22},{"key":31,"text":97,"correct":22},{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":28,"analysis":33},936762,"某通信楼，设置IG541管网灭火系统，该系统的机械应急操作装置设在（ ）。",[244,246,248,250],{"key":20,"text":245,"correct":22},"防护区内",{"key":24,"text":247,"correct":22},"消防控制室内",{"key":28,"text":249,"correct":26},"贮瓶间内或防护区外便于操作的地方",{"key":31,"text":251,"correct":22},"防护区泄压口处",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":28,"analysis":33},936763,"某县城市政给水管网为枝状，现有一栋15层办公楼，每层建筑面积3000平方米，层高4m，在距离建筑150m范围内有2个市政消火栓，则该办公楼最少应设置（ ）室外消火栓。",[256,258,260,262],{"key":20,"text":257,"correct":22},"0个",{"key":24,"text":259,"correct":22},"1个",{"key":28,"text":261,"correct":26},"2个",{"key":31,"text":263,"correct":22},"3个",{"id":265,"libraryId":5,"type":266,"typeLabel":267,"stem":268,"options":269,"answer":281,"analysis":33},936764,2,"多选题","某项目室内消防给水系统采用镀锌钢管，水泵扬程为1.0MPa，系统工作压力为1.32MPa，下列关于管网试压和冲洗的说法中，正确的是（ ）。",[270,272,274,276,278],{"key":20,"text":271,"correct":26},"水压强度试验压力为1.72MPa",{"key":24,"text":273,"correct":22},"水压强度试验的测试点设在最不利消火栓处，管网注水排气时，缓慢升压达到0.35MPa压力后稳压30min，管网无泄漏、无变形，且压力降≤0.05MPa",{"key":28,"text":275,"correct":26},"管网冲洗在水压强度试验后，按供水干管、水平管和立管的顺序进行",{"key":31,"text":277,"correct":26},"水压严密性试验应在水压强度试验和管网冲洗合格后进行。试验压力应为系统工作压力，稳压24h，应无泄漏",{"key":279,"text":280,"correct":26},"E","气压严密性试验的介质宜采用空气或氮气，试验压力应为0.28MPa，且稳压24h，压力降不应大于0.01MPa","ACDE",{"id":283,"libraryId":5,"type":266,"typeLabel":267,"stem":284,"options":285,"answer":296,"analysis":33},936765,"某消防技术服务机构对已完工的防烟排烟系统进行检测。下列做法中，错误的是（ ）。",[286,288,290,292,294],{"key":20,"text":287,"correct":22},"采用发烟器分别对消防电梯前室及附近的两只感烟探测器进行模拟火灾试验，待相应的正压送风机启动后，使用风速仪对消防电梯前室设置的送风口处的风速进行测量，获得测量结果并观察消防联动控制器是否接收到相应正压送风的动作信号",{"key":24,"text":289,"correct":26},"对二层商场电动排烟垂壁附近的一只感烟探测器进行发烟试验。观察电动排烟垂壁的自动降落情况",{"key":28,"text":291,"correct":22},"手动打开设在地下车库的排烟阀，待相应的排烟风机启动后，使用风速仪对排烟口处的风速进行测量，获得测量结果并观察消防联动控制器是否接收到相应排烟阀、排烟风机的动作信号",{"key":31,"text":293,"correct":26},"启动地下车库的排烟系统，手动关闭排烟风机入口处总管上设置的排烟防火阀，观察排烟风机的运行状态及消防联动控制器接收到相应排烟阀、排烟风机动作信号的有关情况",{"key":279,"text":295,"correct":26},"某商场的一防火分区设机械排烟系统，共10个防烟分区，其中有一个防烟分区设置了两个排烟口，当进行模拟火灾试验时，发现该防烟分区只有一个排烟口动作","BDE",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":28,"analysis":33},936766,"某消防控制室内的设备采用双面布置，在值班人员经常工作的一面，设备面盘至墙的距离不应小于（ ）m。",[301,303,304,305],{"key":20,"text":302,"correct":22},"1.5",{"key":24,"text":237,"correct":22},{"key":28,"text":181,"correct":26},{"key":31,"text":235,"correct":22},{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},936767,"某重要设备间，要求自动喷水系统处于准工作状态时，严禁管道漏水，严禁系统误喷。可以选择（ ）。",[310,311,312,313],{"key":20,"text":168,"correct":22},{"key":24,"text":166,"correct":26},{"key":28,"text":170,"correct":22},{"key":31,"text":314,"correct":22},"水幕系统",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":20,"analysis":33},936768,"某总建筑面积为7000m2，建筑高度为80m的办公建筑，下列供电电源中，不能满足该建筑消防用电设备供电要求的是（ ）。",[319,321,323,325],{"key":20,"text":320,"correct":26},"有城市一个区域变电站引来2路电源。并且每根电缆均能承受100%的负荷",{"key":24,"text":322,"correct":22},"由城市不同的两个区域变电站引来两路电源",{"key":28,"text":324,"correct":22},"由城市两个不同的发电厂引来两路电源",{"key":31,"text":326,"correct":22},"由城市一个区域变电站引来一路电源，同时设置一台自备发电机组",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":31,"analysis":33},936769,"某座位数为2000个的影剧院的舞台口设置水幕系统，喷水点高度为10米，则水幕系统喷水强度应为下列（ ）。",[331,332,334,335],{"key":20,"text":199,"correct":22},{"key":24,"text":333,"correct":22},"0.9L\u002Fs·m",{"key":28,"text":201,"correct":22},{"key":31,"text":205,"correct":26},{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":31,"analysis":33},936770,"判断油浸电力变压器设置水喷雾灭火系统时，下述各项设计技术要求中错误的是（ ）。",[340,342,344,346],{"key":20,"text":341,"correct":22},"系统应采用离心雾化型，其工作压力应不小于0.35MPa",{"key":24,"text":343,"correct":22},"水雾喷头应布置在变压器的周围，保护面积应扣除底面面积",{"key":28,"text":345,"correct":22},"系统应设置自动控制、手动控制和应急操作三种控制方式",{"key":31,"text":347,"correct":26},"系统的计算流量按保护对象的保护面积和设计供给强度的乘积确定",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":24,"analysis":33},936771,"泡沫灭火系统按系统结构可分为固定泡沫灭火系统、半固定泡沫灭火系统、移动泡沫灭火系统。半固定灭火系统是指（ ）。",[352,354,356,358],{"key":20,"text":353,"correct":22},"采用泡沫枪、固定泡沫设置和固定消防水泵供应泡沫混合液的灭火系统",{"key":24,"text":355,"correct":26},"泡沫产生器和部分连接管道固定，采用泡沫消防车或机动消防泵，用水带供应泡沫混合液的灭火系统",{"key":28,"text":357,"correct":22},"泡沫产生器与部分连接管道连接，固定消防水泵供应泡沫混合液的灭火系统",{"key":31,"text":359,"correct":22},"采用泡沫枪，泡沫液由消防车供应，水由固定消防水泵供应的灭火系统",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":362,"options":363,"answer":28,"analysis":33},936772,"泡沫一水喷淋系统与泡沫喷雾系统是泡沫系统常见的应用形式，下列关于泡沫一水喷淋与泡沫喷雾系统的描述中正确的是（ ）。",[364,366,368,370],{"key":20,"text":365,"correct":22},"泡沫—水喷琳系统泡沫混合液连续供给时间不应小于5min",{"key":24,"text":367,"correct":22},"泡沫—水喷琳系统泡沫混合液与水的连续供给时间之和不应小于30min",{"key":28,"text":369,"correct":26},"泡沫一水预作用系统与泡沫一水干式系统的管道充水时间不宜大于1min",{"key":31,"text":371,"correct":22},"泡沫一喷雾系统当保护油浸电力变压器时，泡沫混合液或泡沫预混液连续供给时间不应小于10min",{"id":373,"libraryId":5,"type":15,"typeLabel":16,"stem":374,"options":375,"answer":31,"analysis":33},936773,"泡沫一水喷琳系统中，泡沫混合液连续供给时间不应小于（ ）min，泡沫混合液与水的连续供给时间之和不应小于（ ）min。",[376,378,380,382],{"key":20,"text":377,"correct":22},"5,30",{"key":24,"text":379,"correct":22},"5,60",{"key":28,"text":381,"correct":22},"10,30",{"key":31,"text":383,"correct":26},"10,60",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":24,"analysis":33},936774,"配电线路敷设在有可燃物的闷顶时，应当采取穿（ ）等防火保护措施。",[388,390,392,394],{"key":20,"text":389,"correct":22},"PVC管",{"key":24,"text":391,"correct":26},"金属管",{"key":28,"text":393,"correct":22},"阻燃管",{"key":31,"text":395,"correct":22},"难燃材料管",{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":33},936775,"设置气体灭火系统的防护区应设有疏散通道和安全出口，使该区人员能在（ ）min内撤离防护区。",[400,402,403,404],{"key":20,"text":401,"correct":26},"0.5",{"key":24,"text":235,"correct":22},{"key":28,"text":237,"correct":22},{"key":31,"text":181,"correct":22},{"id":406,"libraryId":5,"type":15,"typeLabel":16,"stem":407,"options":408,"answer":31,"analysis":33},936776,"设置消防水泵时应设置备用泵，但当建筑高度为50米的住宅的室外消防用水量小于或者等于（ ）L\u002Fs时，可不设置备用泵。",[409,411,412,414],{"key":20,"text":410,"correct":22},"10",{"key":24,"text":125,"correct":22},{"key":28,"text":413,"correct":22},"20",{"key":31,"text":415,"correct":26},"25",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":28,"analysis":33},936777,"室内消火栓的安装位置，栓口距离地面或楼板的高度宜为（ ）m，其出水方向应（ ）或与设置消火栓的墙面相（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"1.3，向下，平行",{"key":24,"text":423,"correct":22},"1.1，向上，垂直",{"key":28,"text":425,"correct":26},"1.1，向下，垂直",{"key":31,"text":427,"correct":22},"1.3，向上，平行",{"id":429,"libraryId":5,"type":266,"typeLabel":267,"stem":430,"options":431,"answer":442,"analysis":33},936778,"室内消火栓检测验收时应符合（ ）。",[432,434,436,438,440],{"key":20,"text":433,"correct":26},"室内消火栓的选型、规格应符合设计要求",{"key":24,"text":435,"correct":22},"同一建筑物内设置的消火栓应采用统一规格的消火栓箱",{"key":28,"text":437,"correct":26},"试验用消火栓栓口处应设置压力表",{"key":31,"text":439,"correct":22},"室内消火栓处应设置直接启动消防水泵的按钮",{"key":279,"text":441,"correct":26},"室内消火栓应设置明显的永久性固定标志","ACE",{"id":444,"libraryId":5,"type":266,"typeLabel":267,"stem":445,"options":446,"answer":457,"analysis":33},936779,"水流指示器一般用于下列（ ）系统中。",[447,449,451,453,455],{"key":20,"text":448,"correct":26},"湿式及干式自动喷水灭火系统",{"key":24,"text":450,"correct":26},"预作用自动喷水灭火系统",{"key":28,"text":452,"correct":26},"循环启闭式自动喷水灭火系统",{"key":31,"text":454,"correct":26},"自动喷水-泡沫联用系统",{"key":279,"text":456,"correct":22},"雨淋灭火系统","ABCD",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":28,"analysis":33},936780,"水喷雾灭火系统的基本设计详见数根据其防护目的和保护对象确定。水喷雾灭火系统用于液化石油气罐瓶间防护冷却目的时，系统的响应时间不应大于（ ）s。",[462,464,466,467],{"key":20,"text":463,"correct":22},"45",{"key":24,"text":465,"correct":22},"120",{"key":28,"text":121,"correct":26},{"key":31,"text":468,"correct":22},"300",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":24,"analysis":33},936781,"水喷雾灭火系统水力警铃测试时，警铃喷嘴处压力不应小于（ ）MPa，且距水力警铃3m处声强不应小于（ ）dB。",[473,475,477,479],{"key":20,"text":474,"correct":22},"0.05，90",{"key":24,"text":476,"correct":26},"0.05，70",{"key":28,"text":478,"correct":22},"0.1，70",{"key":31,"text":480,"correct":22},"0.1，50",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":33},936782,"水喷雾系统给水管道工作压力不应大于（ ）。",[485,487,489,491],{"key":20,"text":486,"correct":22},"2.0MPa",{"key":24,"text":488,"correct":26},"1.6MPa",{"key":28,"text":490,"correct":22},"1.2MPa",{"key":31,"text":492,"correct":22},"1.0MPa",{"id":494,"libraryId":5,"type":266,"typeLabel":267,"stem":495,"options":496,"answer":457,"analysis":33},936783,"水喷雾系统每月应检查的项目为（ ）。",[497,499,501,503,505],{"key":20,"text":498,"correct":26},"应检查电磁阀并进行启动试验",{"key":24,"text":500,"correct":26},"应检查手动控制阀门的铅封、锁链",{"key":28,"text":502,"correct":26},"应检查消防水池（罐）、消防水箱及消防气压给水设备",{"key":31,"text":504,"correct":26},"应检查消防水泵接合器的接口及附件",{"key":279,"text":506,"correct":22},"应检查室外阀门井中进水管上的控制阀门，核实其处于全开启状态",{"id":508,"libraryId":5,"type":266,"typeLabel":267,"stem":509,"options":510,"answer":521,"analysis":33},936784,"水喷雾系统系统调试时应包括（ ）。",[511,513,515,517,519],{"key":20,"text":512,"correct":22},"水源控制阀测试",{"key":24,"text":514,"correct":26},"动力源和备用动力源切换试验",{"key":28,"text":516,"correct":26},"消防水泵和稳压泵调试",{"key":31,"text":518,"correct":26},"雨淋报警阀、电动控制阀、气动控制阀的调试",{"key":279,"text":520,"correct":26},"排水设施调试和联动试验","BCDE",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":20,"analysis":33},936785,"通过采样管采样的吸气式感烟火灾探测器根据使用环境的不同，需要对采样管道进行定期吹洗，最长的时间间隔不应超过（ ）年。",[526,527,528,529],{"key":20,"text":235,"correct":26},{"key":24,"text":181,"correct":22},{"key":28,"text":95,"correct":22},{"key":31,"text":101,"correct":22},{"id":531,"libraryId":5,"type":266,"typeLabel":267,"stem":532,"options":533,"answer":544,"analysis":33},936786,"为确定系统设计详见数的实体火灾模拟试验应由国家授权的机构实施。在工程应用中采用实体模拟实验结果时，应符合下列（ ）规定。",[534,536,538,540,542],{"key":20,"text":535,"correct":26},"系统设计喷雾强度不应小于试验所用喷雾强度",{"key":24,"text":537,"correct":26},"喷头最低工作压力不应小于试验测得最不利点喷头的工作压力",{"key":28,"text":539,"correct":22},"系统设计流量不应小于试验所用设计流量",{"key":31,"text":541,"correct":26},"喷头布置间距和安装高度分别不应大于试验时的喷头间距和安装高度",{"key":279,"text":543,"correct":26},"喷头的安装角度应与试验安装角度一致","ABDE",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":20,"analysis":33},936787,"系统检测时，施工单位应提供的资料不包括（ ）。",[549,551,553,555],{"key":20,"text":550,"correct":26},"安全和功能检验资料的核查记录",{"key":24,"text":552,"correct":22},"工程质量事故处理报告",{"key":28,"text":554,"correct":22},"施工现场质量管理检查记录",{"key":31,"text":556,"correct":22},"竣工检测申请报告、设计变更通知书、竣工图",{"id":558,"libraryId":5,"type":266,"typeLabel":267,"stem":559,"options":560,"answer":571,"analysis":33},936788,"细水雾灭火系统喷头的选择及布置正确的是（ ）。",[561,563,565,567,569],{"key":20,"text":562,"correct":26},"对于环境条件易使喷头喷孔堵塞的场所，应选用具有相应防护措施",{"key":24,"text":564,"correct":22},"对于电子信息系统机房的地板夹层，宜选择适用于狭长空间的喷头",{"key":28,"text":566,"correct":26},"对于闭式系统，同一防护区内应采用相同热敏性能的喷头",{"key":31,"text":568,"correct":26},"对于电缆隧道等狭长防护区域，可以采用线形方式布置喷头",{"key":279,"text":570,"correct":22},"对于保护室内油浸变压器时，喷头宜分层布置","ACD",{"id":573,"libraryId":5,"type":15,"typeLabel":16,"stem":574,"options":575,"answer":24,"analysis":33},936789,"细水雾灭火系统瓶组供水装置，容器组的布置应便于检查、测试、重新灌装和维护，其操作面距墙或操作面之间的距离不宜小于（ ）m。",[576,577,579,581],{"key":20,"text":401,"correct":22},{"key":24,"text":578,"correct":26},"0.8",{"key":28,"text":580,"correct":22},"1.0",{"key":31,"text":582,"correct":22},"1.2",{"id":584,"libraryId":5,"type":15,"typeLabel":16,"stem":585,"options":586,"answer":28,"analysis":33},936790,"细水雾灭火系统中最大的过滤器过滤等级或目数应保证不大于喷头最小过流尺寸的（ ）。",[587,589,591,593],{"key":20,"text":588,"correct":22},"60%",{"key":24,"text":590,"correct":22},"70%",{"key":28,"text":592,"correct":26},"80%",{"key":31,"text":594,"correct":22},"90%",{"id":596,"libraryId":5,"type":266,"typeLabel":267,"stem":597,"options":598,"answer":609,"analysis":33},936791,"细水雾是指在最小设计工作压力下，经喷头喷出并在喷头轴线下方1.0m处的平面上形成的雾滴粒径（ ）的水雾滴。",[599,601,603,605,607],{"key":20,"text":600,"correct":26},"Dv0.50小于200μm",{"key":24,"text":602,"correct":26},"Dv0.99小于400μm",{"key":28,"text":604,"correct":22},"Dv0.50小于100μm",{"key":31,"text":606,"correct":22},"Dv0.99小于1000μm",{"key":279,"text":608,"correct":22},"Dv0.99小于500μm","AB",{"id":611,"libraryId":5,"type":15,"typeLabel":16,"stem":612,"options":613,"answer":31,"analysis":33},936792,"下列（ ）场所可不设消防备用泵。",[614,616,618,620],{"key":20,"text":615,"correct":22},"室外消防用水量为30L\u002Fs的仓库",{"key":24,"text":617,"correct":22},"建筑高度为54m住宅",{"key":28,"text":619,"correct":22},"室外消防用水量为20L\u002Fs的丙类工厂",{"key":31,"text":621,"correct":26},"室内消防用水量为10L\u002F的建筑",[623,626,629,632,635,638],{"id":15,"name":624,"category":7,"favorite":625},"领导干部任职前廉政法规知识测试题",92,{"id":627,"name":628,"category":7,"favorite":15},595,"建筑结构与设备",{"id":630,"name":631,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":633,"name":634,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":636,"name":637,"category":7,"favorite":8},534,"BIM工程师",{"id":639,"name":637,"category":7,"favorite":8},535]